Plans[Page Too Large for OCR Processing] / 3 33 S iv co i2kiuy 2 2c I P52 ! - 0 © �55 Bulletin 136 Rev.L Mo d el F1 FR l ® Model F1 FR Recessed . Quick Response Sprinklers Do 0 r Model Fl FR Sprinkler Types Standard Upright Standard Pendent Conventional ` • ' 1 == = Vertical Sidewall n,;, Horiz Sidewall `` ` 'r 7 - HSW 1 Deflector • -- 1 Model F1FR Recessed Sprinkler Types Recessed Pendent ---.1.,,,-.---:.-_, Recessed Horizontal Sidewall - HSW 1 Deflector Upright Pendent Listings & Approvals - 1. Listed by Underwriters Laboratories, Inc. (UL) . `i. - ; ,4 '''' - 2. Listed by Underwriters' Laboratories of Canada (ULC) \, 3. Certified by FM Approvals 1 • 4. Loss Prevention Council (LPC, UK) . 5. NYC BS &A No. 587 -75 -SA 6. Meets MIL- S -901C and MIL -STD 167 -1 ` ) 7. Verband der Schadenversicherer (VdS, Germany) . 8. NYC MEA 258 -93 -E U i .. =_-- L Listing Category Sprinklers, Automatic & Open • Quick Response Sprinkler Vertical Sidewall Conventional UL Guide Number VNIV Product Description ,. Reliable Models F1FR and F1FR Recessed Sprinklers are ' I k ' , quick response sprinklers which combine the durability of a q Po P tY =-; 4 standard sprinkler with the attractive low profile of a decorative ' Ili : , r • sprinkler. r..-- _ The Models F1FR and F1FR Recessed automatic sprinklers _ 4. � - utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This Horizontal Sidewall Recessed Pendent quick response enables the Model Fl FR and Fl FR Recessed HSW 1 Deflector sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. Application The glass bulb consists of an accurately controlled amount Quick response sprinklers are used in fixed fire protec- of special fluid hermetically sealed inside a precisely manufac- tion systems: Wet, Dry, Deluge or Preaction. Care must be tured glass capsule. This glass bulb is specially constructed to exercised that the orifice size, temperature rating, deflector provide fast thermal response. The balance of parts are made style and sprinkler type are in accordance with the latest of brass, copper and beryllium nickel. published standards of the National Fire Protection Asso- At normal temperatures, the glass bulb contains the fluid ciation or the approving Authority Having Jurisdiction. in both the liquid and vapor phases. The vapor phase can Quick response sprinklers are intended for installation as be seen as a small bubble. As heat is applied, the liquid ex- specified in NFPA 13. Quick response sprinklers and stan- . pands, forcing the bubble smaller and smaller as the liquid dard response sprinklers should not be intermixed. pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. The temperature rating of the sprinkler is identified by the color of the glass bulb. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type K Factor Sprinkler Identification Standard - Upright (SSU) and Pendent (SSP) U Metric Sprinkler OAgparpiization Number (SIN) Deflectors Marked to Indicate Position SSU SSP /" (15mm) Standard Orifice with y" NPT (R /) Thread 5.6 80 2.2" (56mm) 1,23,4,5,6,7 R3625 R3615 '3/42' (20mm) Large Orifice with 3/ NPT (R3/4) Thread 8.0 115 2.3" (58mm) 1,23,4,7,8 R3622 R3612 %' (17mm) Small Orifice with /" NPT (R /) Thread 4.2 60 , 2.54" (65mm) 1,2,8 R3623 R3613 3/ (10mm) Small Orifice with /" NPT (R /) Thread 2.8 40 2.54" (65mm) 1,2,8 R3621 R3611 10mm Orifice XLH with R3/4" Thread 4.2 60 56.1mm 4,6,7 R3624 R3614 Conventional-Install in Upright or Pendent Position 10mm Orifice XLH with R% Thread 4.2 60 56.1mm — R3674 15mm Standard Orifice with /" NPT (R /) Thread 5.6 80 56.1mm 4,6,7 R3675 20mm Large Orifice with 3/4" NPT (R 8.0 115 58.4mm 4,7 R3672 '� : � 't' tea? 1I .. • / . • III .‘"" i t � � -a;� -- - . Upright Pendent Upright Conventional • Model Fl FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model RC1 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Approvalt' Sprinkler Identification ' Orifice Size US Metric Height Organizations Number (SIN) / (15mm) / NPT (R'/z) 5.6 80 2.2' (56mm) 1,2,3,4,5,7,8 R3615 ' %z' (20mm) 3 /," NPT (R /4) 8.0 115 2.3" (58mm) 1,2,3 R3612 T / 6' (11mm) y NPT (R%) 4.2 60 2.54" (65mm) 1,2,8 R3613 %" (10mm) }Z" NPT (R%) 2.8 40 2.54" (65mm) 1,2,8 R3611 10mm R3 4.2 60 56.1mm 4,7 R3614 (1) Refer to escutcheon data table for approvals and dimensions. ...I- 1 V4 ROLE OK (07 ?..) F r rs/re 544 _J (�91 1 _ + _ 1' X I/7' REDUCER TURN COLLAR ultra TAGrff Acroar SPRp,QER WREN H BOSS ram or i nMAG re Ai (0 =11...............11 " IV / /%J CUM DaiENSION • ,,e � (umml ail • 127/.L2 at (721n.,) - ,J6,wlO (11 RETER TO ESCU1CNEON MIA TABLE FOR APPROVALS AND O4LEMSrONS. 2. Model Fl FR Quick Response Vertical Sidewall. Sprinkler - ' Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approval Sprinkler identification US Metric Organizations Number (SIN) Y" '/z " NPT(R%) 5.6 80 2.2"(56mm) 1,2,3,6,8 R3685 15mm /z" NPT (R') 5.6 80 2.2" (56mm) 4 (1) (1) LPC Approval is for Pendent position only. •�"'"•T Orientation Deflector to Ceiling '- rtio Upright 4" - 12" (102mm - 305mm) Pendent 6" - 12" (152mm - 305mm) Vertical Sidewall • • Model Fl FR Quick Response Horizontal Sidewall Sprinkler - Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: V Approval Organizations . Sprinkler K Factor and Type of Approval Identification Nominal Thread - Sprinkler Number Hazard Hazaard d y Orifice Size US Metric Length Light Ordinary (SIN) y" (15mm) j2" NPT(R%) 5.6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL and ULC Listing permits use with F1 or F2 recessed escutcheon. , • • _,... 7,A ! t i s / Ail r -' � i - , . Tl _ " IJ 1 ,{ � `1 .. j'cf`dy it ', ,:,-A.‘ 1, .. : gi { • ' " _ • Horizontal_Sidewall _ 3. • Installation • • Sprinkler Types Quick response sprinklers are intended for installati . Standard Upright as specified .in NFPA 13. Quick response sprinklers and • Standard Pendent standard response sprinklers should not be intermixed. Conventional The Model F1 FR Recessed Quick Response Sprinklers Sidewall (Vertical, Horizontal HSW1) are to be installed as shown. The Model Fl or F2 Escutch- eons illustrated are the only recessed escutcheons to be Recessed Pendent used with the Model Fl FR Sprinklers. The use of any other ' Recessed Horizontal Sidewall HSW1 • recessed escutcheon will void all approvals and negate all warranties. When installing Model Fl FR Sprinklers, use the Model D Sprinkler Wrench. When installing Model Fl FR Recessed Finishes "" Sidewall Sprinklers, use the Model GFR1 Sprinkler Standard Finishes Wrench. Use the Model RC1 Wrench for installing F1FR sprinkler Escutcheon Recessed Pendent Sprinklers. Any other type of wrench Bronze Brass may damage these sprinklers. Chrome Plated Chrome Plated (3) White Polyester Coated White Painted (3) Temperature Ratings Special Application Finishes Sprinkler Sprinkler Escutcheon Max Classification Temperature • Ambient Bulb Bright Brass Bright Brass , C °F Temp. Color Black Plated Black Plated Ordinary 57 135 100'F(38°C) Orange Black Paint Black Paint . Ordinary 68 155 100°F(38°C) Red Off White Off White Intermediate 79 175 150°F (66°C) Yellow • Satin Chrome Satin Chrome Intermediate 93 200 150°E (66°C) , Green • High (1) 141 286 225F(107°C) Blue' ( Other finishes and colors are available on. special order. (1) Not available for recessed sprinklers. Consult the factory for details. • ( FM Approvals is limited to bronze and brass, chrome or black • plated finishes only. Escutcheon Data (3) FP Push - on/Thread -off escutcheon F-ace cot Fitting Escutcheon . model Approvals Adjustment Dimension Ong or . Wall Dimension . Fl 1,2,4 X," X" X8 "-'5 Ordering Information • (19mm) (19mm) (5mm -24mm) Specify: . - F2 1,2,3,4,5,7,8 X,. 1 ". /e' 1. Sprinkler Model (13mm) (25mm) (5mm -17mm) • . 7 2. Sprinkler Type FP 1,2 Full y Recessed (11mm) 3. Orifice S ize Thread-off � 1,2 Fully Retracted 'K" 4. Deflector Type _ (24mm) 5. Temperature Rating • . . Maintenance • 6. Sprinkler Finish The ' Models F1FR and ..F1 FR Recessed Sprinklers : 7. Escutcheon Type . should be inspected quarterly and the sprinkler system 8. Escutcheon Finish- (where applicable) maintained in accordance with NFPA 25. 'Do not clean • sprinklers with soap and water, ammonia or any other Note: When Model F1FR Recessed sprinklers are cleaning fluids. Remove dust by using a soft brush or gen- ordered, the sprinklers and escutcheons are packaged tle vacuuming. Remove any sprinkler which has been . separately. painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained ' I in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation. or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. • Manufactured by . is The Reliable Automatic S Co Inc ® Pa Recyclec r • ., per (800)431 -1588 Sales Offices • I I e (800)848 -6051 Safes Fax Corporate Offices lia.' Revision lines indicate updated or new data 1 - (914)668 -3470 www.reliablesprinkler.com Internet Address • EG. Pr.nteo In U.S.A. 3/03 P/N9999970027 • Bulletin 172 co Model JL112 & J112 ECLH /ECOH Reliabi6 Exten Coverage Light Hazard &Ordinary Hazard N •Pendentand Recessed Pendent Sprinklers Model JL112 & J112 ECLH /ECOH Pendent & Recessed Pendent SIN RA 7216 is Corrosion Resistant with White (SIN R7216 - Link and RA7216 - Bulb) Polyester Coating. - Quick Response for Light Hazard • • - Standard Response for Ordinary Hazard Features 1. Extended Coverage Ordinary Hazard and Light ? .� • Hazard protection to 400 ft (37.2m) per sprinkler., 2. Nominal K = 11.2 (160). ;e..1.1 i' 3. Available in Pendent or Recessed Pendent styles. 4. Recessed pendent version provides 3 /4" (19mm) . adjustment to flush pendent position (see � . adjustment table). 5. Available in brass, chrome and polyester coated u �' finishes. _: ti. ..: 6. For applications as per NFPA 13. • Approvals Organizations Model JL112 Pendent Model J112 Pendent 1. Underwriters Laboratories, Inc. (UL) (R 7216) (RA 7216) 2. Underwriters Laboratories of Canada (cULus) UL Listing Category Design Criteria • Sprinklers, Automatic and Open Extended Coverage Reliable Model JL112 & J112 ECLH /ECOH sprinklers Sprinklers- Ordinary Hazard Occupancy UL Guide shall only be used in systems designed and installed in Number - VNIV. accordance with NFPA 13 and all other local codes and The Reliable Model JL112 and J112 sprinkler are ordinances. The following design criteria also apply: Extended Coverage Sprinklers for use in both Light and • Minimum sprinkler spacing is 8 ft. Ordinary Hazard 1 and 2 occupancies with a coverage • Sprinklers have a minimum flow requirement for each area of up to 400 square feet per sprinkler. For ordinary spacing as shown in the Flow Requirements Table on hazard applications it is a Standard Response the reverse side. Sprinkler. For light hazard applications it is Quick • ECOH sprinklers are only to be used in system Response Sprinkler. hydraulically designed per NFPA 13 for a minimum The use of ECLH /ECOH sprinklers can provide lower area of 1500 ft or 5 sprinklers, whichever is greater. installation costs by requiring fewer sprinklers, less • Deflector to commodity clearance shall be a piping and reduced labor. minimum of 18 in (457mm). ECLH and ECOH sprinklers are to be installed • ECOH sprinklers shall be installed in unobstructed according to the design criteria shown in this bulletin, constructions as defined in NFPA 13. For open web NFPA 13, and all other local codes and ordinances. truss construction web thickness is not to exceed 1 Flows and pressures as shown on pages 2 and 3 of this inch. bulletin, must be used for the appropriate spacing and • ECOH sprinklers which are installed above the for the designated hazard classifications. bottom of a horizontal obstruction, shall have their This ECLH /ECOH sprinkler is available in various deflectors located as shown in the Obstruction Table finishes to include a corrosion resistant finish. on page 3. ECOH sprinklers are standard response and are • Sprinklers can be installed under a sloping ceiling not . available in a pendent or an attractive recessed exceeding - 2 inches of rise in 12 inches. - "- pendent type which • provides up to 3 /4" (19mm) of • Maximum working pressure is 175 psi at the sprinkler. escutcheon adjustment. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford NY 10523 • Sprinkler Model Specifications Temperature Rating Max. Ceiling Temp. Maximum Maximum Sprinkler Model Type Sprinkler Coverage THD Size Approvals °F °C °F °C Spacing Area JL112 - ECOH - R7216 Link/Pendent 165 74 100 38 20' 400 ft JL112 - ECOH - R7216 Link/Recessed 212 100 150 66 34• 1.2 155 68 100 38 J112 - ECOH - RA7216 Bulb /Pendent NPT J112 - ECOH - RA7216 Bulb/Recessed 200 93 150 66 20 400 Flow Requirements - Ordinary Hazard - Standard Response Ordinary Hazard 1 Ordinary Hazard 2 "K" Factor Spacing Coverage Area 0.15 gpn>/ft Density 0.20 gpmlft Density 'Flow 'Pressure *Flow *Pressure US Metric 14' x 14' 196 ft 30 7.2 39 12.1 and less 16' x 16' 256 ft 39 12.1 51 20.7 11.2 160.0 18' x 18' 324 ft 49 19.1 65 33.7 20' x20' 400 ft 60 28.7 80 51.0 Flow is in gpm and pressure is in psi Recessed Pendent ECLH /ECOH Adjustments Recess Escutcheons ECLH ECOH F1 /F2 FP Escutcheon R7216 RA7216 R7216 RA7216 FP 3 /4 3 /4 3 /4 3 /4 �` ' - Fl n/a n/a 3 /7 3 A . cy F2 h /2 n/a n/a • --- . * Adjustments in inches. = Finishes `•, Sprinkler Finishes Sprinkler Escutcheon Model J1 Model J112 Sprinkler Wrench Sprinkler Wrench Bronze Brass Use Model J1 Wrench for Use Model J112 Wrench for Chrome Chrome JL112 & J112 ECLH/ECOH JL112 & J112 ECLH/ECOH White Polyester Coated White Painted Pendent Sprinkler Removal Recessed Sprinkler Removal and Installation and Installation Ordering Information J1 Wrench J112 Wrench 1 • Sprinkler Model • 2. Temperature Rating 3. Finish 4. Escutcheon and finish (where applicable) ^,:,�� 1,„: - 1 LFl1l - • % - -. -i - Corrosion Resistant • Bulb • J112 ECLH/ECOH °F °C ". ------ 155 68 200 93 2. • 1 • • ° ' - Minimum Flow Requirements For Earlier Editions of NFPA 13 - FOR REFERENCE ONLY ' - NFPA13 =1991 Requirements NFPA13 -1989 Requirements "K" Factor . Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 3 • Spacing Coverage Area 0.15 gpmfft 0.20 gpmfft 0.16 gpm/ft 0.19 gpmfft 0.21 gpm/ft2 US Metric Density • Density, Density Density Density 'Flow 'Pressure 'Flow Pressure 'Flow Pressure 'Flow Pressure 'Flow 'Pressure 14' x 14' 196 ft 30.2 7.0 39.2 11.9 31.4 7.6 37.3 10.7 41.2 13.0 and less 16' x 16' 256 ft 38.4 11.4 51.2 20.2 41.0 12.9 48.7 18.2 53.8 22.3 11.4 164.4 18' x 18' 324 ft 48.6 18.2 64.8 32.3 51.9' 20.7 61.6 29.2 68.0 35.7 20' x 20' 400 ft 60.0 27.7 80.0 49.3 64.0 31.5 76.0 44.5 84.0 54.3 *Flow is in gpm and pressure is in psi Flow Requirements - Light Hazard,- Quick Response - Flow Pressure • • "K" Factor Spacing Coverage Area (gpm) (psi) US i Metric 16' x 16' • 256 ft 30- 7 • 18' x 18' 324 ft . 33 9 11.2 160 20' x 20' • 400 ft 40 13 Location of Deflector to Horizontal Obstruction Distance from Sprinkler Maximum Allowable Distance ":‘'!...--:3" �. Deflector Above Bottom of ' to Side of Obstruction Obstruction _ - % -- Less than 1' • 0' r. ,,":,, ti � : / . 1p' : .^.w'S: SPRMA:C9 . 1' to less than 1' - 6° 0" (E; , w -, . _ I • 1' - 6' to less than 2'... 1" - : ' " . r�o :mm' �. ' • I \: ) � = Cf'u � O:E 0u 2' to less than 2'. -6" 1' - T,-.2. - -: . 2' 6' to less than 3' 1' -' _ i "' ` r ' J ° " ° " r IIU __ - . . :O C_UNC. 3' to less than 3' - 6° 3" .. ;0.,',1,; 0.,',1,; - ; °, ` r : fv - : ��� i il to less than 4' - 6' 5' f `� . /� // /i ` , V2. 4' - 6' to less than 5' 7' r% J ; - 5 to less than 5 - 6' 7' • I •.•_ t 5' - 6' to less than 6' 7° . 6' to less than 6'• -6° 9' ;',„' 6' - 6' to less than 7' 11' 2 f:';;',•4.° . 7' and greater 14' Fig. 1 - Fl Escutcheon • • Solder Link Bulb • Classification °F °C Classification °F °C Bulb Color _ Ordinary -- 165 74 -- - -- Ordinary - -- 155 -- - - -68 - -- - -••- Red - • - Intermediate 212 100 Intermediate 200 93 Green 3. •