Loading...
Specifications r 0005g' -A %.;: Co (32_2_1Si P kf�y iteez • �� SYSTEMS �4° : "Zq i 4„. '''t .. , A.� f Selectable- Output =' i; Horns, Strobes, and % ' 4. Horn Strobes a 1 , . c SpectrAlert' Advance selectable-output horns, strobes, - a 4•d<. and horn strobes are rich with features guaranteed to p��� cut installation times and maximize profits. SPECTRAlert AwaravrAtainarri Features The SpectrAlert Advance series offers the most versatile and • Plug -in design with minimal intrusion into the back box easy -to -use line of horns, strobes, and horn strobes in the industry. Tamper resistant construction With white and red plastic housings, wall and ceiling mounting • options, and plain and FIRE - printed devices, SpectrAlert Advance can • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 meet virtually any application requirement. candela • Field- selectable candela settings on wall and ceiling units: 15, 15/75, Like the entire SpectrAlert Advance product line, horns, strobes, 30, 75, 95, 110, 115, 135, 150, 177, and 185 and horn strobes include a variety of features that increase their • Horn rated at 88+ dBA at 16 volts application versatility while simplifying installation. All devices • Rotary switch for horn tone and three volume selections feature plug-in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually • Universal mounting plate for wall and ceiling units eliminating costly and time- consuming ground faults. Furthermore, • Mounting plate shorting spring checks wiring continuity before a universal mounting plate with an onboard shorting spring tests device installation wiring continuity before the device is installed, protecting devices • Electrically compatible with existing SpectrAlert products from damage. • Compatible with MDL sync module In addition, field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings T SIGNALING ( 5) ® ® MEA ifimg, roved 7g5165P186 OnAOaOob,,) LISTED APPROVED approved 7115- 1653188(homsttobn, 54011 (d2mes. horn strobes. horns) 3023572 MEA45205 -E chine strobes) 55512 (strobes) 7135 - 1653187 (horns. oh mes) • SpectrAlert Advance Specifications . i Architect /EngineerSpecifications "' General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 1'/ -inch back box, 4 -inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 11/4-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24- volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95,110,115,135,150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 "%6 x 4 11 /16 x 21/2-inch back box. The module shali'also control two Style Y (class B) circuits or one Style Z (class A) circuit.The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical /Electrical Specifications ' 1 �;' � ;'' � " " . 4a� A Standard Operating Temperature 32 °F to 120 °F (0 °C to 49 °C) Humidity Range 10 to 93% non- condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8 x 2.5" high (173 mm diameter x 64 mm high) Wall -Mount Dimensions (including lens) 5.6" L x 4.7 "W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6" L x 4.7 x 1.3 - 0 (142 mm L x 119 mm W x 33 mm D) Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW -2) 5.9 x 5.0 "W x 2.2 (151 mm L x 128 mm W x 56 mm D) Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7.1" diameter x 2.2" high (180 mm diameter x 57 mm high) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR -HS, TRW -HS) 5.T L x 4.8 "W x 0.35 (145 mm L x 122 mm W x 9 mm D) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC- HS,TRCW -HS) 6.9" diameter x 0.35 (175 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05 -0395-007 • • UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) > ' a ' ULM Horn Current Draw (mA RMS) ? • e'.`s : : L!': . - : 8 -17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15175 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non - temporal High 57 56 69 75 95 NA NA 181 176 Non- temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 • Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 . 185 NA NA 286 258 • UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela Range (15 -115 cd) - 8 -17.5 Volts 16 -33 Volts DC input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 ' 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non - Temporal Medium 133 145 75 85 102 163 187 207 216 Non - Temporal Low 131 '144 68 79 96 156 182 201 210 FWR Input - Temporal High 136 155 88 97 " 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non- Temporal Medium 134 155 85 95 110 166 189 208 216 Non - Temporal Low 132 154 80 90 105 161 184 202 211 ,1.11:1Vlax. Current; Draw(MA RMS), '2 -Wire Horn Strobe, Higli Candela Range (135- 185:cd) - ? .cT'> ti4 4:‘. 1 `-_ :.:',...7.•,,.14k ?'' , A.. , , "' ' 16-33 Volts 16 -33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 • 290 297 Temporal High 215 231 258 265 Temporal Medium 235 ' 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non - Temporal Medium 242 259. 293 299 Non Temporal Medium 219 232 262 267 Non - Temporal Low 238 254 291 • 295 Non Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 4-6rn and Horn 'Strobe Output (dBA) €, , q f't+r r 8 -17.5 16 -33 24 -Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 • . 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non - Temporal Low 75 75 81 81 88 84 96 92 7r Coded High 82 82 88 88 93 92 101 101 — -- ----8s—• —Coded Medium- 78- 78- 85--- 85- 90- 90- 97 -98— -- - - -- — 9 Coded Low 75 75 81 81 88 85 96 92 • 'Settings 7, 8, and 9 are not available on 2 -wire horn strobe. A0S- 0395-007 • SpectrAlert Advance Dimensions 4.7' 2.5" 6.8' Dre. • lb loll 5.6" 1 Wall -mount horn strobes Ceiling -mount horn strobes 7.1" 12.25+1 5.05" 2.231 - --� Dia. I o coo I /oo c °o\ 5.98" c Ili 7oi • - . o o0 00, r Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information . . Model Description Model Description . Wall Horn Strobes Ceiling Strobes P2R•t 2 -Wire Horn Strobe, Standard cdt, Red . SCR Strobe, Standard cd, Red P2RH' 2 -Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red • P2W• 2 -Wire Horn Strobe, Standard cd, White SCW' Strobe, Standard cd, White P2WH• 2 -Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White P4R' 4 -Wire Horn Strobe, Standard cd, Red Horns P4RH 4 -Wire Horn Strobe, High cd, Red HR Horn, Red P4W 4 -Wire Horn Strobe, Standard cd, White HW Horn, White Wall Strobes Accessories SR" Strobe, Standard cd, Red BBS-2 Back Box Skirt, Wall, Red SRH" Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White SW' Strobe, Standard cd, White BBSC -2 Back Box Skirt, Ceiling, Red SWH' Strobe, High cd, White BBSCW -2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes TR -HS Trim Ring, Wall, Red PC2R' 2 -Wire Horn Strobe, Standard cd, Red • TRW -HS Trim Ring, Wall White. PC2RH 2 -Wire Horn Strobe, High cd, Red TRC -HS Trim Ring, Ceiling, Red PC2W" 2-Wire Horn Strobe, Standard cd, White TRCW -HS Trim Ring, Ceiling, White PC2WH' 2 -Wire Horn Strobe, High cd, White PC4R 4 -Wire Horn Strobe, Standard cd, Red PC4RH 4 -Wire Horn Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White Notes: • Add to model number for plain housing (no'FIRE'marking on cover), e.g., P2R-P. t Add' - SP'to model number for 'FUEGO' marking on cover, e.g., P2R -SP. 4 Standard cd'refers to strobes that include 15,15/75, 30, 75, 95.110, and 115 candela settings 'High cd' refers to strobes that include 135, 150, 177, and 185 candela settings. -- - • - • - —( \ \` \ 07009 system Sensor. — — - -- — ® 3825 Ohio Avenue • St. Charles, IL 60174 ,spe�a�mvm,ea to change mm m tmace. rsysteteareamr .SENSOR' Phone: 800- SENSOR2 • Fax: 630-377-6495 current product od oe na00An 'tsdng ""l'testveiionoltividac'heet A054395-037 #N9 #2132 • • INTELLIKNIGHT ACCESSORY , . \ \ °°Q 5g' J 30". _• ��� \ \ c .,.. ' ' t-41' Addressable / `; , -.'"'N, �' 4. ^ �. ��v 3 .R 1 , •Q ' otoelectric Type 9)(Q� NIN t \ ��o Smoke Detector � . ar t • �- .,,,,�,� . Detect smoldering fires quickly and get , "° ., ., „ h elp fast with IntelliKnight photoelectric r 1�,� -�_ - . smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505 -APS photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505 -APS compensates automatically for contamination in the environment. And detector testing is simple —even from a remote site. Like other IntelliKnight detector models, the SD505 -APS offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505 -6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors —easy installation, stable operation, RF /transient protection, and vandal- resistant locking —and it adds up to a flexible solution for all your fire protection needs. Model SD505 -APS The light received is converted into Analog / Addressable an electronic signal. Under normal Photoelectric Type conditions, the status LED blinks Smoke Detector approximately every 15 seconds, 1 / The SD505 -APS is particularly indicating that the head is suited to detecting dense smoke communicating with the loop. The typical of fires involving materials LED lights continuously during the • such as soft furnishings, plastic, alarm period. foam or other similar materials Features which tend to smolder and produce • Low profile, 2 inches, including SD505 -APS Smoke Detector large visible particles. base Specifications The detector features automatic • Simple and reliable addressing Operating Voltage: 17 - 41 VDC compensation for contamination without mechanical switches Current Consumption: and a simple detector calibration • Automatic compensation for test procedure that can be run from sensor contamination Standby: .55 mA the panel or remotely (using the Alarm: .55 mA • Built-in fire test feature WindowsTM based downloading Simple detector calibration Ambient Temperature: 32 °F to 120 °F • software ). (0 ° C to 49°C) testing through the control panel Operation or remotely through a Mounting: 4" Square, 4" The SD505 -APS units made up of WindowsTM based computer OCT, Single an LED light source and a silicon software. gang mud ring photo diode receiving element. In a • Vandal- resistance locking Relative Humidity: 85% normal standby condition, the features noncondensing receiving element receives no light • Field cleanable Air Velocity: 0 - 300 FPM from the pulsing light source. In the • UL listed, meets NFPA 72 Ch 7 event or fire, smoke enters the requirements Compatible Bases: SD505 -6AB detector and light is reflected from (Sold Separately) (6" Base) • the smoke particles to the receiving CSFM approved SD505 4AB element. • MEA approved (4" Base) • FM Approved SILENT 4 4 KNIGHT by Honeywell INTELLIKNIGHT ACCESSORY Model SD505 -APS Addressable Photoelectric Type i� J. Smoke Detector )/ \ n iV( v ... Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505 -APS. The combination detector head, and twist -lock base, shall be UL® listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505 -AIS Ionization Smoke Detector, or SD505- AHS Heat Detector. Base shall be the appropriate twist -lock base SD505 -6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505 -APS shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. 1 � Diameter = 5- 15/16" M • ��N Diameter = 3- 15116" /� � '\ 14 ■1 • i CD( ( o 1C -� I J I Height = 2 inches, \ = ,�' / J I including base �� Model SD505 -6AB Detector Base Model SD505 -APS Detector Head (front view) (front view) SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to -date and accurate. We cannot cover all . specific applications or anticipate all requirements. All specifications are FORM# 350225 Rev C,. 05/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]