Specifications FP5 201 — 0003q- - i 9& / / Geht o L03 SIEMENS Siemens Infrastructure & Cities 15201 NW Greenbrier Pkwy, Suite A4 Beaverton, OR 97006 Phone: (503) 207-1900 Fax: (503) 207 -1901 Siemens Infrastructure & Cities Fire Alarm System Contractor Horizon Retail Construction Electrical Contractor • FIRE ALARM SUBMITTAL Washington Square JOSEPH A. BANKS Suite L03 Siemens Job Number 440P- 106964 • Siemens Project Manager Charles Hughes Submittal Version Date Siemens Project Engineer Marc Sobottke Issued For Permit/Construction ' 02116/12 Proprietary document for approval only Table of Contents SIEMENS BILL OF MATERIAL & COMPONENT SPECIFICATIONS 2 BATTERY CALCULATIONS BILL OF MATERIALS SIEMENS Washington Square JOSEPH A. BANKS Suite L03 Fire Alarm System Item Part # Qty Mfg Mfg# Description 1 FP -11 9 Siemens 500 - 095112 Intellegent Photoelectric Smoke Detector 2 DB -11 5 Siemens 500 - 094151 Detector Base for FP -11 3 AD2 -XHR 4 Siemens 500 - 649708 Air Duct Housing For FP -11 with Relay • No Data Sheet Available • PROPRIETARY DOCUMENT FOR APPROVAL ONLY 1 2/16/2012 • SIEMENS Fire Safety FP -11 FirePrintTM Detector Intelligent Fire Detector for MXL, MXL -IQ, and MXLV Control Panels ENGINEER AND ARCHITECT SPECIFICATIONS • Most Sophisticated "Detector Intelligence" available today • Multi- Criteria fire detection for the price of a photoelectric detector • FirePrintTMTechnology to discriminate between deceptive phenomena and an actual fire • Easily programmed to match specific hazard profiles from the control panel • Pre -Alarm reporting based on fire profile selected - • Remote sensitivity measurement capability System logic activation based on any of three inputs from V • detector (smoke, heat or neural network) • Field cleanable chamber with replaceable chamber parts available • Multi -color detector status LED • Two-wire operation • Compatible with Model DPU or FPI -32 field programmer /tester • Supports EnviroLINK software based automatic a environmental compensation • Backward compatible with older MXL systems (Rev. 2 and above) • Optional fully programmable relay base , audible base, and duct housing • ® UL Listed, ULC Listed, CSFM, FM, NYMEA Approved Introduction The FP -11 Intelligent Fire Detector provides the life need for cumbersome, unreliable mechanical program - safety industry with the most highly evolved detection ming methods and reduces installation and service system available today. The FP -11 utilizes advanced costs by electronically programming and testing the detection technology that allows the detector to detector prior to installation. distinguish nonthreatening deceptive phenomena, such as cigarette smoke, from actual fire hazards, while The FP 11 fire detector is compatible with the MXL optimizing detection for the area in which it is in- family of control panels including the MXL, MXL-IQ, stalled. No other detection system available today and MXLV. offers a higher level of protection or nuisance The FP -11 detector is Underwriters Laboratories and alarm immunity. The FP -11 uses state -of- the -art Underwriters Laboratories of Canada Listed. microprocessor circuitry with error check, detector self- diagnostics and supervision programs. Description The FP 11 intelligent fire detector is compatible with The FP -11 is a plug -in, two -wire, multi- sensor detector the Siemens Building Technologies, Fire Safety Divi with both photoelectric and thermal inputs and is sion, Model DPU or FPI -32 field programmer /tester, compatible with the MXL family of control panel which is a compact, portable, menu driven accessory systems. Each detector consists of a dust resistant, for electronically programming and testing detectors, field cleanable photo chamber, a solid state easily and reliably. The DPU or FPI -32 eliminates the CATALOG NUMBER 6175 non - mechanical thermal sensor, microprocessor based evaluating this information with sophisticated electronics with a low- profile plastic cover and base. mathematical formulas, or algorithms, comparing this The FP -11 utilizes state -of- the -art ASIC and surface input to characteristics of both threatening fires and mount technology for maximum reliability. Every FP -11 deceptive phenomena that would "fool" any ordinary fire detector is shipped with a protective dust cover. detector. This technology was developed over years of The FP 11 fire detector utilizes an infrared light research and reviewing the results of over 20 years of emitting diode ( IRLED), and light sensing photodiode. fire test data in one of the world's most advanced fire research centers. The results of this research are the Under normal conditions, light transmitted by the LED mathematical models that form the algorithms used in is directed away from the photodiode and scattered • FirePrint. No other fire detector has this level of through the smoke chamber in a controlled pattern. intelligence or this amount of research and develop - The smoke chamber is designed to manage light ment supporting it's design. dissipation and extraneous reflections from dust particles or other non -smoke airborne contaminants in The microprocessor's software can identify and such a way as to maintain stable, consistent detector disregard false input caused by radio frequency (RFI) operation. When smoke enters the detector chamber, and electromagnetic (EMI) interference, and validates. light emitted from the IRLED is scattered by the all trouble conditions before annunciating or reporting smoke particles and is received by the photodiode. to the control panel. The FP -11 detector's microproces- sor uses an integral EEPROM to store the detector's The FP -11 also utilizes a modern, accurate, shock- address and other critical operating parameters which resistant thermistor to sense temperature changes. include the assigned program values for alarm and The "on board" FirePrint technology allows the trouble thresholds. Communications within the • detector to gather smoke and thermal data, and to detector itself and between the FP -11 and the control analyze this information in the detector's "neural network" By comparing data received with the panel, or with the FPI -32 field programmer /tester, are supervised and safeguarded against disruption by common characteristics of fires, or fire fingerprints, reliable, microprocessor based error checking routines. the FP -11 can compare these "Fire Prints" to those of Additionally, the microprocessor supervises all deceptive phenomena that cause other detectors to EEPROM memory locations and provides a high alarm. The advanced FirePrint technology allows the degree of EEPROM failure fault tolerance. FP -11 to accurately determine a true fire hazard from a nonthreatening deceptive phenomena WITHOUT In MXL(V) applications, the FP -11 determines its needing to use alarm delaying verification and confir- operating status to be normal, in alarm, or in trouble mation techniques, which can increase the probability depending on the difference between the alarm of losses due to fire. threshold values stored in the detector's memory and the detector's latest analog measurement. The The FP 11 provides the highest level of detector detector then communicates changes in its status to intelligence available today with a detector /control the control panel. panel link that allows the user to program the detector for the specific hazard profile Detectors are optimized In addition, the MXL(V) control panel will sample the by selecting one of the following applications: value of the FP -11's analog signal over a period of time in order to determine if those values indicate exces- • Office /Retail sive buildup, in the photo chamber; if so, the MXL(V) • Lobby will indicate that the particular detector •requires • Computer Room maintenance. • Dormitory • Healthcare The FP -11 is listed as a self- testing device. The FP -11's • Parking Garage visible light emitting diode (LED) flashes green every • Utility/Transformer Room 4 seconds to indicate it is communicating with the • Hostile Environment control panel and that it has passed its internal self- • Precious Storage test. Should the detector sense a fault or failure within • Air Duct its systems, the LED will flash amber and the detector • Warehouse /Light Manufacturing will transmit that information to the control panel. The software does the rest; no guessing on detector A quick visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed sensitivities or alarm verification; the control panel information is required, a printed report can be programs the FP -11 detector for the protected area provided from the MXL panel indicating the status without hassle and without confirmation delays. and settings assigned to each individual detector. Once optimized for the hazards in the protected area, the FP -11 provides the best detection you can buy. When the FP -11 moves to the alarm mode, it will flash Should the operator or installer forget to program the amber and transmit that information to the control detector, the FP -11 will revert to a default setting that panel. When the MXL(V) confirms the detectors allows it to operate as a standard photoelectric or condition, the panel will instruct the FP -11 to flash red photothermal detector. and to continue flashing until the system is reset at the control panel. At that same time, any user defined The FP -11's FirePrint technology monitors input from both the photo chamber and the thermal sensor, • • • • • system alarm functions programmed into the system All FP -11 detectors are approved for operation within • are activated. Each FP -11 detector can operate one the UL specified temperature range of 32 to 100 remote alarm indicator, one auxiliary relay, or one degrees F (0 to 38 degrees C). audible base. Detector sensitivity, calibration, and identification are Application Data dynamically supervised by the control panel. Detector Installation of the FP -11 series of fire detectors sensitivity and pre -alarm levels are a function of the requires a two-wire circuit of 18 AWG (minimum) application chosen at the control panel and are thermoplastic fixture wire enclosed in conduit, or 18 controlled by the panel. If an alternate, non - FirePrint AWG limited energy, shielded cable without conduit, mode is selected, then the sensitivity can be changed if permitted by local codes. Field wiring should from the control panel. conform to local and National Electric Codes and the The DPU or FPI -32 Program/Test accessory is used to control panel wiring specifications. • program and verify the detector's address. The "T- tapping" is permitted only for Style 4 (Class B) technician selects the accessory's program mode to wiring. enter the desired address. The DPU or FPI -32 auto- matically sets and verifies the address and tests the FP -11 fire detectors can be applied within the maxi - detector. It also allows the user to change the device mum 30 foot center spacing (900 sq. ft. areas) as ID from that of an FP -11 to an older detector ID such as referenced in NFPA 72. This applications guideline is an ILP -1, ILPT -1, ILP -2, ID -60P or ID -60PT to allow for based on ideal conditions, specifically, smooth ceiling easy replacement of older detectors without the need surfaces, minimal air movement, and no physical of reprogramming the control panel. obstructions between potential fire sources and the • detector. Do not mount detectors in close proximity The FPI -32 operates on AC power or rechargeable to ventilation or heating and air conditioning outlets. batteries, providing flexibility and convenience in Exposed joints or beamed ceilings may also affect safe programming and testing equipment almost anywhere. spacing limitations for detectors. Should questions When in the test mode, the DPU or FPI -32 will perform arise regarding detector placement, observe NFPA a series of diagnostic. tests without altering'the 72 guidelines. address or other stored data, allowing technicians to • determine if the detector is operating properly. Good fire protection system engineering and common sense dictate how and when fire detectors are The FP -11 fire detector may be installed on the same installed and used. Contact your local Siemens initiating circuit with IL or ID series detectors (Photo- Building Technologies, Fire Safety Division authorized electric, thermal, or ionization), MSI series manual sales outlet whenever you need assistance applying stations, TRI series interfaces, ICP output control FirePrint in unusual applications. Be sure to follow devices, or CZM series of addressable, conventional NFPA guidelines, UL /ULC approved installation zone modules. instructions, which are included with every detector, All FP 11 detectors can be cleaned in the field, when and local codes as 'for all fire protection equipment. required, by simply removing the detector cover and unsnapping the photo chamber. There is also the Dimensions. option of cleaning the interior of the detector with a • clean, soft cloth or brush, or replacing the labyrinth and 6' Diameter Base bug screen included in the detector maintenance kit, model DMK -11. The FP -11 uses the low profile surface mounting base, �� • . model DB -11. This base mounts on a 4 -inch octagon, T - square, or a single gang electrical box. The base 2.3° l' utilizes screw clamp contacts for electrical connections overall - � Height .: .. , . • and self- wiping contacts for increased reliability. The • base can be used with the optional LK -11 detector < <7 ►_ 7 locking kit which contains 50 detector locks and an IL installation tool, to prevent unauthorized removal of the detector head. The DB -11 base has integral decora- tive plugs to cover the outer mounting screw holes. The FP -11 is electrically compatible with existing MXL detector accessories including relays, remote lamps, • duct housings, and audible bases. With duct housings, - -- a base - adapter -and- new - detector - housing- cover -are - - required (order AD -11 UK upgrade kit). To use existing . DB -3S base or audible base: the FP -11 requires a DB- ADPT base adapter. • • • • Technical Specifications Curre'nt..Requirements: Normal 750 pa Alarm 750 pa • •Operating'Temperature: +32 °F (0 °C) to 100 °F (38 °C) per UL 268/268A Humidity: 0 -93% Relative Humidity Non - Condensing • Ordering Information • Part Model Description Number FP-11 Addressable FirePrint Fire Detector 500- 095112 DB -11 Detector Mounting Base for Series 11 500- 094151 DB -11E Detector Base (Small) 500- 094151E AD2 -P Air Duct Housing for use with FP -11, HFP -11, HFPO -11, 500- 649706 PE -11 AD2 -XHR Air Duct Housing for use with FP-11, HFP-11, HFPO -11 500- 649708 with relay • ADBX -11 Audible Base 500- 096181 DB -X11RS Relay Base for Series 11 Intelligent Detectors 500- 096125 RU -1 " Remote (red) alarm indicator- 4' octagon box mount • 500- 390673 RU -2 Remote (red) alarm indicator single gang box mount 500-390674 • LK -11 Base Locking Kit for Series 11 detectors 500- 695350 . DMK -11 Series 11 Maint Kit (replacement labyrinth and bug . 500. 695338 bug screen). _ DB-ADPT - Base Adapter to DB -3S Base • 500.09418T In Canada Order: • . - • FP -11C ' Addressable FirePrint Fire Detector (ULC) 500- 095112C • DB -11C Detector Mounting Base for Series 11 (ULC) . 500- 095687 AD -11 PC Air Duct Housing (ULC) 500 - 095984 DB -X11 RSC Relay Base for Series 11 Intelligent Detectors (ULC) 500-096125C ADBX -11 C Audible Base for Series 11 Intelligent Detector (ULC) 500-096181C • • • • • Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard • Florham Park, NJ 07932 5 /06 Brampton, Ontario Siemens Buildin Technolo ieS Tel: (973) 593 -2600 1OM Canada L6T 5E4 g g FAX: (973) 593 -6670 SFS-IG Tel: 1905) 799-9937 May 2006 Fire Safety Website: www.sbt.siemens.com /fis Printed in U.S.A. FAX: (905) 799 - 9858 Supo,sodes them dated 6/03 SIEMENS Fire Safety Installation/Wiring Instructions MODEL DB- 11/ -11E DETECTOR BASE END OF LINE DEVICE (NOTE POLARITY DB- 11/ -11E (NO REMOTE DEVICE) DB -HR (REMOTE RELAY BASE) WHEN APPLICABLE) + 1b 1b _ TO INITIATING • • / SEE REMOTE DEVICE INSTRUCTIONS FOR WIRING DETAILS: + CIRCUIT OF la 1 b INSTALLATION SBT, INC. 5 6 DEVICE INSTRUCTIONS COMPATIBLE RR -11 P/N 315 - 094924 CONTROL UNIT a t • 6 RLC -11, RLW -11 P/N 315- 094925 — SEE CAUTION 1 � 5 RSAC -11, RSAW -11 P/N 315 - 094926 MULTIPLE REMOTE DEVICES CAUTION: If remote devices are supported by the initiating circuit, each detector /base may 1. Do not use looped wire under base terminal 5. Break wire have up to 2 remote devices with the following configurations and restrictions only: run to provide supervision of connection. Remote Remote Dev Device 2 Restrictions 2. When a remote relay is used to control a critical system RR -11 RLC -11, RLW -11 See Caution 2 function, the relay and its associated detector and optional 11, R RSAC -11, RSAW -11 See Caution 2 y p RLC -11, LW -11 RSAC -11, RSAW -11 Wire from base to module(s) must be the ONLY devices on the initiating circuit. RLC -11, RLW -11 RLC -11, RLW -11 RSAC -11 /RSAW -11 to RL -11 Figure 1 Wiring Diagram for DB- 11/ -11 E usi PE -.11, PE-117; and DT -11 Detectors • + DB- 11/ -11E (NO REMOTE DEVICE) + + DB -11XRS (REMOTE RELAY BASE) + + TO NEXT BASE DO NOT /---:-. USE AN ■ + END OF LINE ♦ Q DEVICE TO INITIATING 5 1a OPTIONAL — 5+ 5 1a m 5+ CIRCUIT OF REMOTE • J RELAY' SBT, INC. ALARM I • NO C ; `CONTACTS 6 lb • • 1 ( NO , 11 I. COMPATIBLE 6 1 b INDICATOR ® Ul • ) (NC • Ili f 3A, 120 VAC ♦ Q . 1� lNC •�� CONTROL UNIT ,♦ O MODELS RLI -2 6 la 3A, 30 VDC ' DO NOT AN 111 _ _ — — — / EIND OF / TO NEXT BASE DEVICE *The relay contacts are shown in the Non -Alarm /System Reset condition. Figure 2 Wiring Diagram for DB -11 / -11 E using FP -11, FPT11, FS -DP, FS -DPT, and FS -DT Detectors DB -11 (NO REMOTE DEVICE) DB -HR (REMOTE RELAY BASE) TO NEXT BASE DO NOT LINE 1" II / /___•,. USE AN . END OF AIN LI NE • • � ♦ Q DEVICE TO INITIATING 5 la OPTIONAL • 15+ 5 la ' 15+ • CIRCUIT OF REMOTE • J ( RELAY' • 1 SBT, INC. ALARM 1 T81 , 1 I No • CONTACTS 6 1 b . 11 NO • M • COMPATIBLE 6 1b INDICATOR TB20 U • J • W } 3A, 120 VAC ♦ Q . J� (NC •�� CONTROL UNIT ,♦ 0 MODELS 3A, 30 VDC ' DO NOT RL -HW / RL -HC TB3 USE AN ilII /---1 END OF LINE 2" / LINE The relay contacts are shown in the Non - Alarm /System Reset condition. TO NEXT BASE DEVICE " HFP- 11/ HFPT- 11 /HFPO- 1ISFP- 11 /SFPT- 11/SFPO -11 is a polarity insensitive detector. Line 1 and Line 2 can be either line of the loop. NOTE: SFP -11 Series detectors are approved for use in Canada only. Figure 3 Wiring Diagram for DB- 11/ -11E using HFP -11 Series and SFP -11 Series Detectors --- Siemens-Building - Technologies - ,--Inc. Siemens - Building Technologies, —std. Model - DB=11 / =1 — ---- 8 Fernwood Road 2 Kenview Boulevard Florham Park, New Jersey 07932 Brampton, Ontario, Canada L6T 5E4 (P/N 500 - 094151/500 094151E) • • • Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. Model DB -11 / -11 E 8 Fernwood Road 2 Kenview Boulevard Florham Park, New Jersey 07932 Brampton, Ontario, Canada L6T 5E4 (P /N 500 DETECTOR AND BASE PLACEMENT ALARM LED US E J JUMPER LOCATION WITM KIT. P DB11 JU IN 500.699167 Detector and base locations shall follow the drawings DETECTOR INSTAL 0 FOR C ONH PE -TINUIT11Y LED ' CHECK WIT provided or approved by Siemens Building Technologies, Inc. IN BASE O PE -11T ORDT-11 DETECTORS or its authorized distributors. This is extremely important! The detector placements shown on these drawings were chosen a ° ��p �_ after a careful evaluation of all facets of the protected area. • . When drawings are not available, refer to Detector Placement r,•� ; _ �i'� I_, � section of detector Installation/Wiring Instructions and to " °% l NFPA Standard 72 and CAN /ULC -S524. BASE WIRING MOUNTING O ff MOUNTING Siemens Building Technologies, Inc.'s detectors should be HOLE COVERS HOLES interconnected as shown in Figures 1, 2 or 3 and wired Figure 4 to the control panel following the wiring connection drawing Mounting The DB -11 Base installed on the inside face of each control panel cover. NOTE: H Series devices are wired to the DLC or FS -DLC; S Series devices are wired to the FDLC. Note any limitations on the ALARM LED / 0 �•� LOCATION WITH FACTORY number of detectors and restrictions on the use of DETECTOR INSTALLED INSTALLED i t(}. JUMPER remote devices permitted for each circuit. IN BASE , 5 O i P ,i .v.1.1 a s ail DETECTOR MOUNTING USINGTHE DB- 11/ -11E BASE `iz cJ � % n y III The detector is provided with a separate base which attaches ? I �/ to a standard 4 inch square, 4 inch octagonal, or single gang `\� r _ - �a(� / electrical box, with the box size and depth required by the NEC for the number and size of conductors used. Wire size: max — 14 AWG, min — 18 AWG. �� / / BASE MOUNTING HOLE Figure 5 Refer to Figures 4 and 5, as applicable. Mounting The DB -11 E Base • 1. Route all wires outward from outlet box. 2. When ALARM LED viewing is critical, position the LED mark in the base in the intended direction. 3. Route wires through the hole in the center of the base and mount base to outlet box. Make connections directly to the base terminals. Refer to Figures 1, 2 and 3 for details. 4. After all bases are installed, check loop continuity. Refer to the System Manual for the loop continuity check procedure. To allow for the continuity check with PE -11, PE -11T or DT -11 detectors, use DBJ -11 Jumper Kit, P/N 500 - 699167 (between terminals 1 a and 1b) to complete the loop. Do not use a jumper for FP -11 /HFP -11 /FS/ SFP -11 family devices. 5. Continuity jumper must be removed from each base prior to installing detector. 6. To insure proper installation of the detector head into the base: a. Route wires away from connector terminals. b. Take up all slack in the outlet box. c. Properly dress and position all wires flat against the base. - - d: Check screw terminals are tight: 7 (DB -11 only) Break off the two mounting hole covers, and insert in two outer base mounting holes. • Installation Instructions P/N 315 - 094193 - • • .2 SIEMENS Catalog Sheet Fire Safety & Security Products Air -Duct Housings and Detectors Air -Duct Housings — AD2 Series Models AD2 -P, AD2 -PR, AD2 -XHR, AD2 -4W, ST(s): 10 25 50 and 100 ARCHITECT AND ENGINEER SPECIFICATIONS • For Series 11 detectors • Relay models available • Design for air - velocity range of 100 to 4000 fpm • Alarm LED visible from front " • • Self- contained model available Ar • with 'on- board' power supply • Clear housing cover for quick 1. g identification of detector -type ; • < • 4 2 , .∎ removable with only (4) captive screws • ®UL and ©ULCListed; CSFM & NYMEA Approved Product Overview The Siemens Building Technologies, Fire Safety Notes - (cont.'d): With the MXL series of control panels, up to 60 Division Air -Duct Detector Housings are designed to detectors (per circuit) having relays may be used. The connection be used with the 11-Series detectors. Designed for of a remote lamp or a remote relay is allowed for each detector but no f or b d e t ec t ors. installation directly to heating, ventilating and air - conditioning duct systems, they comply with National With the FireFinder XLS series of control panels, up to 252 detectors (per circuit) having relays may be used. The connection of an Fire Protection Association Standard No. 90A. When intelligent remote lamp and a remote Relay (ILED) is also allowed. equipped with photoelectric detectors, these units will Air -duct housings (see: Details for Ordering) are ()Underwriters' signal the presence of hazardous quantities of Laboratories, Inc. listed. products of combustion or smoke being carried through the duct system. Air -duct detectors are Specifications not intended to be substituted for open -area The air -duct housing is uniquely designed to use the detection. photoelectric detector. Sensitivity of PE -11 detectors Air -duct housings can be equipped with optional relays. can be checked by viewing the LED or an RSAW- 11 or These relays are utilized to operate any supplementary RSAC -11 multicolor remote lamp. A green flash equipment when smoke or particles of indicates the detector has passed its self test. combustion are detected. Amber indicates a trouble condition, and red indicates Notes: Most conventional time control equipment guarantee only 1 an alarm state. HFP -11, HFPO -11 and FP -11 sensitivity detector per zone when the detector operated relay function is may be viewed from the multi -color LED on the critical. The connection of a remote lamp and a remote relay detector or, preferably, may be printed by command per detector is allowed with PXL or System 3TM only; other conventional systems may use either a remote lamp or a relay. on an optional printer from the MXL control panel. Air -Duct Housings and Detectors 6185 Building Technologies Fire Safety & Security Products - • � Specifications — (continued) The detector unit employs a cross - sectional sampling All that is necessary for installation of the air -duct principle of operation. Inlet sampling tubes are detector is the cutting of three small holes for the available in four lengths (see: Sampling Tube Selection sampling tube installation (template included), and Table). Outlet sampling tubes are one common length. the drilling of four holes for mounting the air -duct A continuous, cross - sectional sample of air moving housing. The unit is then easily mounted in place, through the duct stratification or skin affect phenomena and connection made to the existing wires or occurring in the duct that could prevent combustion terminals, if optional accessories are utilized. product or smoke (especially in large ducts) from ST -50 and ST -100 require support. ST -100 is shipped in reaching a spot -type detector. two, five -foot pieces with a coupling for field assembly. In addition, the unique design of the sampling chamber insures uniform sensitivity in air velocities, ranging from Technical Data a low of 100 feet per minute to as high as 4,000 feet per minute. The housing comes with 3 wiring entry ports: Temperature Range: 32 ° F (0 ° C) 100 ° F (38 °C) (2) 1/2" conduit knockouts and (1) 1/2" conduit opening. Altitude Range: No Altitude.Limitations The inlet sampling tube length is determined by the Relative Humidity: • 10 - 85% width of the air duct being protected. The inlet tube .(non- condensing I non - freezing) greater than and nearest to the duct width should be , Air -Duct Velocity Range: 100 - 4000 Ft. /Min. used (see: 'Sampling Tube Selection Table). The inlet Sampling Tube Pressure Greater than. 0.01 amps; less tube can then be trimmed at the job site to the exact Range of Differences: than 1.2 inches of water column width of the duct. The outlet sampling tube for all Note (to Architect): When building codes regulate the location of ducts, irrespective of width, has a fixed length of detectors within ventilating systems, make sure the number and approximately 5.5 inches and is supplied with the locations of detectors is in accordance with the code regulations. air -duct housing. Note: When the use of a remote relay is required, order model Details for Ordering AD2 -PR for conventional systems; AD2 -XHR for addressable systems. Model Part • When required the WP -2000 weatherproof enclosure for duct Description housing is available. Number Number (For full details, refer to installation instructions part number AD2-P 500-649706 Air -Duct Housing for use with FP -11, 315 - 049708.) HFP -11, HFPO -11 and PE -11 Note: When a self - contained duct detector with power supply i Air -Duct Housing for use with FP -11, required, order model AD2-4W. AD2 -PR 500- 649707 HFP -11, HFPO -11 and PE -11 (For full details, refer to installation instructions part number AD2 -XHR 500- 649708 Air -Duct Housing for use with PE -11 relay 315- 049708.) AD2 4W 500-649709 Air7Duct Housing for use with FP -11, Sampling Tube Selection Table • HFP -11 and HFPO -11 (with relay) Sampling Tube ST -10 500- 649710 Sampling tube for Ducts 6" to 1' Duct Width ST -25 500 - 649711 Sampling tube for Ducts over 1' to 3' (Model No.) For duct widths 6" to 1' ST -10 ST -50 500- 649712 Sampling tube for Ducts'3" to 5' For duct widths 1' to 3' ST -25 ST -100 500 - 649713 Sampling tube for Ducts 5' to 10' For duct widths 3' to 5' ST -50 • (requires support) Product Includes: For duct widths 5' to 10' ST -100 - (1) short - return (outlet) tube (requires support) (1) stopper Maintenance of the detector is easily accomplished - (2) #12 + 314 ",sheet -metal screws by the removal of the Series 11 duct - housing - (1) mounting template sampling chamber cover. The detector, which plugs into the housing, is easily removed for cleaning by Note: Detector and sampling tube to be purchased separately. Minimum hardware•required is: (1) air -duct housing assembly; a trained technician. (1) sampling tube and (1) detector. Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. - — - -- For- the - most- up -to- date - information,- refer -to- each - product's- installation - instructions. - -- Fire Safety & Security Fire Safety & Security 8 Femwood Road 2 Kenview Boulevard Building Technologies . Florham Park, NJ 07932 Brampton, Ontario Fire Safety & Security Products Tel: (973) 593 -2600 sFS L6T 5E4 / Canada September 2009 FAX: (908) 547 -6877 Printed in U.S.A. Tel: (905) 799 -9937 Supersedes sheet dated 9/06 URL: www.SBT.Siemens.com /FIS FAX: (905) 799 -9858 (Rev. I) • . • PANEL BATTERY CALCULATIONS SIEMENS Washington Square MAIN FIRE ALARM PANEL MXLV . Requirement for standby current: 24 Hours Design Supervison Current = 31.13 Amp-Hr E Requirement for alarm current: 15 Minutes ' Design Alarm Current = 1.31 Amp -Hr E Spare Battery Capacity: 20 % Additional Capacity Current = 6.49 Amp-Hr 3 Initiating Devices Assumed In Alarm: 10 % Battery AH requirement = 38.93 Amp -Hr U) • Battery Size' 55.00 Amp-Hr I Module Part Number & Description Quantity Modulo Current EOL Current Device Current Total Standby 24 VDC Modulo Current • Main Control Panel 1 175mA 0.175 Amps MMB -12/3 NAC Circuits 0 12mA per NAC • , 0.000 Amps . . IAC Devices 0 1.1mA per device 0.000 Amps PSR -1 Remote Power Supply 0 • 70mA 0 0 0.000 Amps MKB-2 Main Keyboard 1 5mA 0 0 0.005 Amps RCC -1 /1F Remote Command Center . • 0 75mA 0 0 0.000 Amps . Remote Command Center 0 75mA 0 0 0.000 Amps RCC -2 . Remote Command Center w/ PIM -1 0 ' 95mA 0 0 0.000 Amps TSP -40 Printer 0 • 70mA 0 0 0.000 Amps ' 0 , 10mA 0 _ - ---- - - 0.000 Amps • CSM -4 Conbollable Signal Module 0 O 12mA. 0.000 Amps CRM -4 Controllable Relay Module 0 15mA • 0.000 Amps Active Relay 0 15mA per active relay • 0.000 Amps O 55mA . 0.000 Amps CZM -4 Remote Conventional Zone Module 0 0 . • 3mA 0.000 Amps ALD -21 Analog Loop Driver . 0 105mA 0 0.000 Amps IAC Devices 0 • 1.1 mA per Device 0 000 Amps XLD -1 Analog Loop Dnver 0 215mA 0 0000 Amps IAC Devices 0 1.1 mA per Device 0.000 Amps 4.r CMI-300 CXL Interface Module 0 30mA 0 0 0.000 Amps C NET -4 Style 4 Network Interface Card 1 5mA 0 0 0.005 Amps 1 NET -7/7M Style 7 Network Interface Card 0 30mA • • 0 0 0000 Amps • . NIM -1 W Network Interface Module 0 70mA - 0 NA 0.000 Amps U REP -1 Netowrk Repeater Module 0 40mA • 0 0 . 0.000 Amps PS-5A . ' Power Supply - 0. 1/4 of 5V Load 0 0 0.000 Amps L PS-5N7 Network Interface/5V Poewr Supply . 0 150mA • 1/4 of 5V Load 0 0 • 0.000 •Amps Q MOI -7 • • Voice and Annunciator Driver • 0 • 120mA 0 0 0.000 Amps ' Cl • _ MOD -16 Output Driver . 0 - 2mA - 0 0 0.000 Amps MID -16 Input Driver 0 2mA 0 0 0.000 ' Amps d 6mA 0 • 0.000 Amps Q CZM -1B6 Conventional Zone Module 0 5mA 0.000 Amps M NA . • 0.000 Amps CO ICP -B6 Intelligent Control Point 0 18mA 2.5mA • NA 0.000 Amps PIM -1 Printer Interface Module 1 10mA 0 NA 0.010 Amps , D2300CP Fiber Interface Module 0 50mA 0 0 0.000 ' Amps SK- 5128/512 Digital Communicator 0 60mA 0 0 0.000, Amps ACM -1 Audio Control Module 1 85mA 0 0 0.085 Amps DMC -1 Digital Message Card 1 50mA 0 0 0.050 Amps • TMM -1 Telephone Master Module 0 71mA 0 0 0.000 Amps ASC -1 Audio Supervision Module 1 22mA 0 0 0.022 Amps ASC -2 Audio Supervision Module . 0 39mA 0 0 0.000 Amps BTC -1 Backup Tone Card 0 44mA 0 0 0.000 Amps EL -410D Amplifier Unit 3 200mA 0 0 0.600 Amps OCC -1 Output Control Card 1 17mA 0 0 0.017 Amps RCM -1 Audio Riser Control Module 1 150mA 0 0 0.150 Amps • VFM -1 Fan Control Module 0 17mA 0 0 0.000 Amps VLM -1 LED Annunciator Module 0 17mA 0 0 0.000 Amps ' ° ---- ---- - - - VSM =1 Switching Module - - - 6 - 17mA 0 0 - 0:102 - Amps - -- ZAC-30 Zone Amplification Card 0 160mA 0 0 0.000 Amps ZC1 -8B Zone Control Card 4 19mA 0 0 0.076 Amps ZC2 -4AB Zone Control Card 0 19mA 0 0 0.000 Amps • . • ZC2 -8B Zone Control Card 0 19mA 0 0 0.000 Amps ZC3 -4AB Zone Control Card 0 18mA 0 0 0.000 Amps . ZCT -8B Zone Control Card 0 34mA 0 0 0.000 Amps . Total Supervisory Current 1.297 Amps Proprietary document for approval only . • . , r . MAIN FIRE ALARM PANEL MXLV (Cont.) 24 VDC Current 5 VDC Current Module Part Number a Description Quantity - Activo I Module Total Active I Module Total MMB -1/2/3 Main Control Panel 1 0.175 500mA Provided PSR -1 Remote Power Supply 0 70mA 800mA Provided PS-5A Power Supply 0 0.000 1 Amp Provided PS-5N7 Network Interface/5V Poewr Supply 0 0.000 500mA Provided MKB-2 Main Keyboard 1 0 0.000 15mA . 0.015 RCC -1/1F Remote Command Center 0 75mA 0.000 0 0.000 Remote Command Center 0 75mA 0.000 0 - 0.000 RCC•2 Remote Command Center cal PIM -1 0 95mA 0.000 0 0.000 TSP-40 Printer 0 70mA 0.000 0 0.000 •- 4+ CSM -4 Controllable Signal Module 0 34mA + 1.5A / circuit 0.000 30mA • 0.000 C CRM-4 Controllable Relay Module 0 75mA 0.000 30mA 0.000 . L CZM-4 Remote Conventional Zone Module 0 720mA 0.000 24mA 0.000 L ALD -2I Analog Loop Driver 0 105mA + 1.1mA / device 0.000 0 0.000 U XLD-1 Analog Loop Driver . 0 215mA + 1.1mA / device 0.000 0 0.000 CMI-300 • CXL Interface Module 0 0 0.000 96mA 0.000 E NET -4 Style 4 Network Interface Card 1 0 0.000 20mA • 0.020 L NET -7/7M Style 7 Network Interface Card 0 0 0.000 120mA 0.000 NIM -1W Network Interface Module 0 0 0.000 160mA • 0.000 • Q REP -1 Netowrk Repeater Module 0 40mA 0.000 0 0.000 M01 -7 . Voice and Annunciator Driver 0 120mA 0.000 175mA • .0 MOD-16 Output Driver 0 850mA . 0.000 - 2niA - 0.000 O MID-16 Input Driver 0 • 32mA 0.000 - . 2MA 0.000 - CZM -1B8 Conventional Zone Module 0 50mA. 0.000 0 0.000 . ICP -B6 Intelligent Control Point • • 0 1.5A 0.000 0 0.000 • PIM -1 Printer Interface Module - 1 0. • 0.000 25mA 0.025 a D2300CP Fiber Interface Module . 0- 0 0.000 200mA 0.000 . m SK- 5128/51" Digital Communicator 0 130mA 0.000 0 0.000 Cl) ACM -1 • Audio Control Module 1 85mA 0.085 176mA 0.176 L TMM -1 Telephone Master Module 0 71mA 0.000 0 0.000 ASC -1 Audio Supervision Module 1 41mA 0.041 29mA 0.029 ASC -2 Audio Supervision Module 0 61mA 0.000 29mA 0.000 a BTC -1 Backup Tone Card 0 44mA 0.000 0 0.000 OCC -1 Output Control Card 1 17mA 0.017 22mA 0.022 RCM -1 Audio Riser Control Module 1 130mA 0.130 80mA 0.080 VFM -1 Fan Control Module 0 90mA 0.000. 0 0.000 VLM -1 LED Annunciator Module 0 160mA 0.000 0 0.000 VSM -1 Switching Module 6 160mA 0.960 0 0.000 ZAC -30 Zono Amplification Card . 0 3A @ 30 Watts 0.000 0 0.000 ZC1 -8B Zone Control Card 4 170mA 0.680 31mA 0.124 ZC2.4AB ' Zone Control Card' - 0 167mA 0.000 30mA 0.000 ZC2.8B' Zone Control Card 0 342mA 0.000 31mA 0.000 ZC3 -4AB Zone Control Card . . 0 168mA 0.000 28mA • 0.000 ZCT -8B Zone Control Card. 0 78mA 0.000 33mA 0.000 • 24 VDC Power Supply Needed MPS -6 24VDC Total 1.913 Amps . 5VDC Total 0.491 Amps 24 VDC & 5 VDC Total Panel Alarm Current) 2.404 Amps i - + Total Alarm 24 VDC C Description Model Number Dovlce Quantity Device Current Module Current k. L = Photoeletric Smoke Detector / Thermal Detector FP -11 I FPT -11 0 0.00075 Amps 0.000 Amps U Digital Communicator SK- 5128/5129 0 0.154 Amps 0.000 Amps 30 Watt Amplifier ' ZAC-30 0 3.000 Amps 0.000 Amps L 100 Watt Amplifier EL -410D 3 .9.500 Amps 28.500 Amps • CU NAC -N1 0 0 •Amps 0.000 Amps Q NAC -N2 0 Amps 0.000 Amps Total Field Device Alarm Current 28.500 Amps Q. Current Footage Voltage %of O Field Wiring Circuits Notes Draw of wire Drop Voltage Wire Guage L Drop Notification Circuit N1 0.000 0.00 0.0% 14 (1) Notification Circuit N2 _- ___ 0.000 0.00 0.0% 14 O 0.00 0.0% 14 � i.r 0.00 0.0% 14 O Note: All figures are approximate until actual conduit routing is obtained. FOR SAMPLE OF CALCULATIONS SEE VOLTAGE DROP CALCULATION SHEET • • Proprietary document for approval only [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]