Specifications FPS 2o 12_ -coo I q0310 /4144.4..S5, / c( GIo Fire Suppression C ! \ ED t LI & Building Products 9 FEB - 1 2012 I ' CITY OF TIGARD Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Email: techserv@tycofp.com. BUILDING DIVISION Series RFII — 5.6 K- factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage General The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The _ Description Protective Cap is temporarily removed ; p during installation and replaced to help s.. • The Tyco® Series RFII Quick Response protect the sprinkler during ceiling in- j. - :: (3 -mm bulb) and Standard Response stallation or finish. The tip of: the Pro- y �� • (5 -mm bulb), 5.6 K- Factor, "Royal • tective Cap can be used ,to mark the c . , ino l Flush II" Concealed Pendent Sprin- center 'of the ceiling hole into plaster , , . klers are decorative sprinklers featur- board or ceiling tiles by gently pu > ing a flat cover plate designed to con- ing the ceiling product against the Pro - ceal the sprinkler. These sprinklers are tective Cap. When ceiling installation optimal for architecturally sensitive ar- is complete, the Protective Cap is re eas such as hotel lobbies, office build- moved and .the Cover Plate /Retainer ings, churches, and-restaurants. Assembly is.installed. Sprinkler Each sprinkler includes a Cover Plate/ As an option, the Series RFII Standard Retainer Assembly and a Sprinkler/ Response (5 -mm bulb) "Royal Flush II" Identification Support Cup Assembly. The separa- Concealed Pendent Sprinklers can be ble, two -piece assembly design pro- fitted with a silicone Air and Dust Seal. Number (SIN) vides the following benefits: (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas TY3531 — 3 mm bulb • • Allows installation of the sprinklers where it is desirable to prevent air and TY3551 — 5 mm bulb and pressure testing of the fire pro- dust from the area above the ceiling to tection system prior to installation pass through the cover plate. of a suspended ceiling or applica- • tion of the finish coating to a fixed NOTICE - ceiling. The Series RFII Concealed Pendent • Permits the removal of suspended Sprinklers described herein must be ceiling panels for access to building installed and maintained in compliance • service equipment without having with this document and with the appli- . to first shut down the fire protection cable standards of the National Fire system and remove sprinklers. Protection Association, in addition to • Provides for 1/2 inch (12,7 mm) of the standards of any authorities having vertical adjustment to allow a mea- jurisdiction. Failure to do so may impair - sure of flexibility in determining the the performance of these devices. length of fixed piping to cut for the The owner is responsible for maintain - sprinkler drops. ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted IMPORTANT with any questions. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions - w i t h respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- _ -_ — stallation can permanently_ damage _ - -_ a sprinkler system or its components and cause the sprinkler to fail to . operate in a fire situation or cause it to operate prematurely. Page 1 of 6 OCTOBER 2009 TFP181 TFP181 Technical 1/2' NPT 7 F ASSEMBLY SEALING ! Data • Sprinkler Approvals FRAME ! i �j% W /l Approvals apply only to the service v 1 � �� CAP ;� � conditions indicated in the Design Cri- �� � teria section. • TY3531 (3 mm Bulb) is UL Listed, SUPPORT ; r 0' l C -UL Listed, LPCB A cLP WITH ( BULB PP roved ( Ref. ROLL FORMED ) No. 094a/10), VdS Approved (Cer- THREADS tificate No. G 4090007), and NYC _ III Approved (MEA 353 -01 -E) as Quick \ COMPRESSION Response. / p' Ml SCR • TY3531 (3 -mm Bulb) is FM Ap- PINS (2) 1 , �� � � proved as Standard Response. I A �� PINS Factory Mutual does not approve .— — _ —_ —__. DEFLECTOR any concealed sprinklers for quick . , (DROPPED response. DEFLECTOR I _Zr ; ; - 'POSITION) -- - - - - - - - - Z -f- - • TY3551 (5 -mm Bulb) is UL Listed, C -UL Listed, FM Approved, LPCB •. SPRINKLER/SUPPORT CUP Approved (Ref. No. 094a/9), and I ASSEMBLY I NYC Approved (MEA 353 -01 -E) as THREAD INTO ' Response: I RETAINER Standard Res P SUPPORT CUP � I WITH THREAD • Approvals for Air and Dust Seal UNTIL MOUNTING 'N O .O 1 ) DIMPLES UL and C -UL Listed for use with the SURFACE IS RFII Standard Response Concealed FLUE WITH EJECTION Sprinkler (TY3551). CEI LING SPRING Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, . ---- C -UL, and NYC tea„ Maximum 175 psi (12,1 bar) by FM, SOLDER • COVER VdS, and LPCB TABS (3) COVER PLATE/RETAINER PLATE Temperature Rating ASSEMBLY . 155 °F /68 °C Sprinkler with 139 °F /59 °C Plate FIGURE 1 200 °F /93 °C Sprinkler with • MODEL RFII CONCEALED SPRINKLER - 165 °F /74 °C Plate' . • • ASSEMBLY Discharge Coefficient • K. 5.6 GPM /psis / (80,6 LPM /bar Adjustment . Design NOTICE 1/2 inch (12,7 mm) Criteria Do not use the Series RFII in applica- Cr► tions where the air pressure above the Finishes See the Ordering Procedure section. The Tyco® Series RFII Concealed Pen- d riliun tp raftts s t throhro ppwn duggh h t thehe Sprri nkkler /Sler/S upport Physical Characteristics dent Sprinklers are intended for fire Cup Assembly can delay sprinkler op- Frame Bronze protection systems designed in ac- eration in a fire situation. . Support Cup... Chrome Plated Steel cordance with the standard instal - Guide Pins Stainless Steel lation rules recognized by the appli- Deflector Bronze cable Listing or Approval agency; for ., Compression Screw Brass example, UL Listing is based on NFPA Bulb Glass 13 and VdS Approval is based on the • Cap Bronze or Copper CEA 4001. Sealing Assembly Beryllium . • Nickel w/ Teflont For more information on LPCB and • Cover Plate Brass VdS Approvals, contact Tyco Fire Sup- • • Retainer Brass pression & Building Products at the Ejection Spring Stainless Steel following office: Enschede, Netherlands Telephone: 31 -53- 428 -4444 . Fax: 31 -53- 428 -3377 The Series RFII Concealed Pendent • . . Sprinklers are only listed and approved with the Series RFII Concealed Cover • • Plates having a factory applied finish. (DuPont Registered Trademark • • TFP181 Page 3 of 6 FACE OF CLEARANCE HOLE Operation SPRINKLER DIAMETER When exposed to heat from a fire, the FITTING DIMENSION C I Cover Plate, normally soldered to the J Retainer at three points, falls away to SPRINKLER I expose the Sprinkler /Support Cup SUPPORT CUP \ ' Assembly. ASSEMBLY `i� The Deflector— supported by the Guide Pins —then drops down to its 1 /2° (12,7 mm) THREADED operational position. D ADJUSTMENT I The glass Bulb contains a fluid that ex- ' f pands when exposed to heat. When FACE OF CEILING, _ the rated temperature is reached, the RETAINING RING � / fluid expands sufficiently to shatter the MOUNTING 4 glass Bulb, activating the sprinkler and SURFACE 1� i allowing water to flow. \ A , t n i til V CLEARANCE y i i i i HOLE ---------T- _ 3/16° to 11/16' MANUFACTURER DEFLECTOR COVER PLATE . b_ (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32° (2,4 mm) POSITION ASSEMBLY COVER PLATE COVER PLATE — PROFILE DEPTH DIAMETER i 11010111 _ DIMENSION B DIMENSION A I■I A: 3 -1/4 inches (82,6 mm) C: 2 -3/8 to 2 -5/8 inches (60,3 to 66,7 mm) B: 3/16 inches (4,8 mm) D: 1 -3/4 to 2 -1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS FIGURE 4 DISPOSABLE PROTECTIVE CAP rl =l F RAME � =l li ARM I% SUPPORT CUP l � ICI /Al:: SQUARE ALIGN ARROWS WITH \� FRAME ARMS _ ■ I r i ACCEPTS ` 0 1/2" SOCKET \ — DRIVE FIGURE 3 RFII SPRINKLER WRENCH TFP181 Page .4 of 6 .. ._ _ Installation Do not attempt to modify or repair a This air gap is necessary for proper damaged sprinkler. operation of the sprinkler. If the ceil- The Tyco® Series RFII must be in- Step 7. When installing an Air and Dust ing requires repainting after sprinkler stalled in accordance with the follow- Seal, refer to Figure 5; otherwise, pro- installation, ensure that the new paint ing instructions. ceed to Step 8. To attach the Air and does not seal off any of the air gap. Dust Seal, verify the angle of the out- Do not pull the Cover Plate relative to NOTICE side edge of the seal is oriented ac- the Enclosure. Separation may result. Do not install any bulb - type sprinkler if cording to Figure 5. Start the edge of Replace sprinklers that: the bulb is cracked or there is a loss the Retainer in the grooved slot of the of liquid from the bulb. With the sprin Air and Dust Seal and continue around • are leaking or exhibiting visible signs kler held horizontally, a small air bub the retainer until the entire Air and Dust of corrosion. ble should be present. The diameter Seal i s engaged • were modified or over - heated. of the air bubble is approximately 1/16 Step 8. Screw on the Cover Plate/ Never paint, plate, coat, or otherwise inch (1,6 mm) for the 155 °F /68 °C and Retainer Assembly until the Retainer alter automatic sprinklers after they 3/32 inch (2,4 mm) for the 200°F/93°C (shown in Figure 2) or the Air and Dust leave the factory. Never repaint facto - temperature ratings. Seal (shown in Figure 5) contacts the ry- painted Cover Plates. If necessary, Obtain a 1/2 inch NPT sprinkler joint ceiling Do not continue to screw on replace them with factory - painted by applying a minimum to maximum the Cover P ceiling pan Assembly ut of it so that e units. Non - factory applied paint can normal Plate/ Retainer you Asseembly torque of 7 to 14 ft. - lbs. (9,5 to 19,0 m l ts a cIf a a you cannot t e t g adversely delay or prevent sprinkler ) g torque the C her levels of for ue can dis- Nm . Higher l position. gagy operation in the event of a fire. tort the sprinkler Inlet with consequent with the Support Cup or you cannot Exercise care to avoid damage to • leakage or impairment of the sprinkler. engage the Cover Plate /Retainer •As- sprinklers before, during, and after in- Do not attempt to compensate for in sembly sufficiently to contact the ceil- stallation. Replace sprinklers damaged sufficient adjustment in the Sprinkler ing, you must reposition the Sprinkler by dropping, striking, wrench twisting, by under or over - tightening the Sprin Fitting. wrench slipping, or the like. Also, re- kler /Support Cup Assembly. Re adjust . place any sprinkler that has a cracked the position of the sprinkler fitting to Care and • bulb or that has lost . liquid from its suit. bulb. (Refer to the Installation section.) Step 1. Install the sprinkler only in the Maintenance If you must remove a sprinkler, do not pendent position with the center -line reinstall it or a replacement without re- of the sprinkler perpendicular to the The Tyco® Series . RFII must be installing the Cover Plate /Retainer As- mounting surface. maintained and serviced in accordance sembly. If a Cover Plate /Retainer As- Step 2. Remove the Protective Cap. with the following instructions sembly becomes dislodged during service, replace it immediately. Step 3. With pipe thread sealant ap- NOTICE Responsibility lies with sprinkler own- plied to the pipe threads, hand - tighten p y p the sprinkler into the sprinkler fitting. Before closing a fire protection sys ers for the inspection, testing, and Step 4. Wrench- tighten the sprinkler tem main control valve for maintenance maintenance of their fire protection using only the RFII Sprinkler Wrench. work on the fire protection system that system and devices in compliance with . (Refer to Figure 3.) •Apply the RFII it controls, obtain permission to shut this document, as well as with the ap- Sprinkler Wrench to the Sprinkler as down the affected fire protection sys plicable•standards of the National Fire shown in Figure 3. tem from the proper authorities and no Protection Association (for example, Step 5. Replace the Protective Cap tify all personnel who may be affected NFPA 25), in addition to the standards P p by this action. of any other authorities having jurisdic- by pushing it upwards until it bottoms tion. Contact the installing contractor out against the Support Cup. (Refer Absence of the Cover Plate /Retainer or sprinkler manufacturer regarding to Figure 4.) The Protective Cap helps Assembly can delay sprinkler opera- any questions. • prevent damage to the Deflector and tion in a fire situation. Arms during ceiling installation and /or When properly installed, there is a Automatic sprinkler systems should be finish. You can also use the Protective nominal 3/32 inch (2,4 mm) air gap be- inspected, tested, and maintained by a to locate the center of the clear- qualified Inspection Service in and /or Cap tween the lip of the Cover Plate and the - with local requirements and /or ance hole by gently pushing the ceiling ceiling, as shown in Figure 2. material up against the center point of national code. the Protective Cap. SUPPORT - SPRINKLER FACE OF ORIENT NOTICE CUP CEILING SEAL As long as the Protective Cap remains ,, ' s OWN ; ►_M_ in place, the system is considered covER J e "Out of Service ". j I PL ATE' RETAINER — Step 6. After the ceiling has been com- � � A � � pleted with the 2 -1/2 inch (63,5 mm) L diameter clearance hole and in prepa- i IA —� ration for installing n the Cover Plate /Re- CLEAN tainer Assembly, remove and discard _ AL ii ii . A j _ __ i , __ROOM... — -- - - - the Protective Cap. — Verify that De- - SEAL flector moves up and down freely. � r - -_ LIP OF COVER RETAINER PLATE If the Sprinkler is damaged and the FIGURE 5 Deflector does not move and down OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551) . freely, replace the entire Sprinkler. • TFP181 Limited Ordering Warranty Procedure • Products manufactured by Tyco Fire Contact your local distributor for Suppression & Building Products availability. When placing an order, (TFSBP) are warranted solely to the indicate the full product name. original Buyer for ten (10) years against defects in material and workmanship Sprinkler /Support Cup Assembly when paid for and properly installed Specify: (SIN), (temperature rating and maintained under normal use and from below) Series RFII Concealed service. This warranty will expire ten Pendent Sprinkler, P/N (specify). (10) years from date of shipment by TFSBP. No warranty is given for prod- 155 °F /68 °C 200 °F /93 °C ucts or components manufactured by TY3531 51- 792 -1 -155 51- 792 -1 -200 companies not affiliated by ownership TY3551 51 -790 -1 -155 51 -790 -1 -200 with TFSBP or for products and corn- ponents which have been subject to Separately Ordered Cover Plate/ misuse, improper installation, corro- . sion, or which have not been installed, Retainer Assembly: • maintained, modified or repaired in ac- Specify: (temperature rating from be- cordance with applicable Standards of low) Series RFII Concealed Cover Plate .. ' the National Fire Protection Associa• with (finish), P/N (specify). tion, and /or the standards of any other 139 °F /59 °C(a) 165 °F /74 °C(b) ' Authorities Having Jurisdictioh: Mate - Brass 56- 792 -1 -135 56- 792 -1 -165 rials found by TFSBP to be •defective Chrome 56- 792 -9 -135 • 56- 792 -9 -165 shall be either repaired or replaced, at Signal White TFSBP's sole option. TFSBP neither (RAL 9003) -792 -4 -135 56- 792 -4 -165 assumes, nor authorizes ' any person Grey White to assume for it, any other obligation (RAL 9002) 56- 792 -0 -135 56- 792 -0 -165 in connection with the 'sale of prod- Pure White (c) ucts or parts of products. TFSBP shall (RAL 9010) 56-792-3-135 56- 792 -3 -165 • not be responsible for sprinkler system Custom 56- 792 -X -135 56- 792 -X -165 design errors or inaccurate or incom- (a) For use with 155 "F /68 "C sprinklers. plete information supplied by Buyer or (b) For use with 200F/93°C sprinklers. Buyer's representatives. (c) Eastern Hemisphere sales only. In no event shall TFSBP be liable, in Sp rinkler Wrench contract, tort, strict liability or under Secify: RFII Spri Wrench, any other legal theory; • for incidental, P/N 5 6- 000 - 1-075. indirect, special or consequential dam- • ages, including but not limited to labor . • - charges, regardless of Whether TFSBP Air and Dust Seal . was informed about the possibility of Specify: Air and Dust Seal, such damages, and in no event shall P/N 56- 908 -1 -001. TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied. including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex -. • clusive remedy for claims based on failure of or•defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability • • or any other. legal Theory. . . This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. • . • • • TFP181 • Page 6 of 6 • • • • © 2008 - 2009 TYCO FIRE SUPPRESSION & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tq co Fire Suppression & Building Products Technical Services 800 - 381 -93121 +1- 401 - 781 -8220 www.tyco - fire.com Series TY -FRB - 2.8, 4.2, 5.6, and 8.0 K- Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage G eneral • Corrosion- resistant coatings, where applicable, are utilized to extend the - - Description life of copper alloy sprinklers beyond _ _ "'� "'� �-'= + t`' that which would otherwise be obtained ( I The TYCO Series TY -FRB, 2.8, 4.2, 5.6, when exposed to corrosive atmo- • l: I . and 8.0 K- factor, Upright and Pendent s I corrosion - resistant Although heres. ` m p g 1 i:: • are quick response, standard coverage, Sprinklers described in this data sheet coated sprinklers have passed- the �' I standard corrosion te of the appli- i ' _ _ '� i = pp ' • cable approval agencies, the testing p is e . : • decorative 3 mm glass bulb -type spray g g �� f = • ' ' sprinklers designed for use in light or not representative of all possible cor- '• _ _ ordinary hazard, commercial occupan- rosive . atmospheres. Consequently, : •t= cies such as banks, hotels, and shop- it is recommended that the end user -- — ping malls. • . • be consulted with respect to the suit- ability of these coatings for any given The recessed version of the Series TY- corrosive environment. The effects of FRB Pendent Sprinkler, where applica- ambient temperature, concentration of ble, is intended for use in areas with a chemicals, and gas /chemical velocity, finished ceiling. This recessed pendent should be considered,.as a minimum, ■wa sprinkler uses one of the following, . along'with the- corrosive nature of the • -- • A two -piece Style 10 (1/2 inch NPT) chemical to which the sprinklers will be i ' • . or Style 40 (3/4 inch NPT) Recessed • exposed. • • . , • % ii I - Escutcheon with 1/2 inch (12,7 mm) of ' An intermediate level of-the Series TY- recessed adjustment or up to 3/4 inch FRB Pendent Sprinklers is detailed - -- •••• (19,1 mm) of total adjustment from the in Technical Data Sheet TFP356, and - ' z • flush pendent position, or a • Sprinkler Guards are detailed in Tech- • A two -piece Style 20 (1/2 inch NPT) nical Data Sheet TFP780. or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of NOTICE Model/Sprinkler adjustment or up to 1/2 inch The Series TY-FRB Concealed Pendent (12,7 mm) of total adjustment from the Sprinklers described herein must be flush pendent position. installed and maintained in compliance Identification The adjustment provided by the with this document and with the appli- N Lei (SIN) Recessed Escutcheon reduces the cable standards of the National Fire b . accuracy to which the fixed pipe drops Protection Association, in addition to to the sprinklers must be cut. the standards of any authorities having TY1131: Upright 2.8K, 1/2" NPT jurisdiction. Failure to do so may impair TY1231: Pendent 2.8K, 1/2" NPT the performance of these devices. - TY2131: Upright 4.2K, 1/2" NPT ' Owners are responsible for maintaining TY2231: Pendent 4 "NPT .. their fire protection system and devices TY3131: Upright 5.6K, 1/2" NPT IMPORTANT in proper operating condition. The TY3231: Pendent 5.6K, 1!2" NPT installing contractor or sprinkler menu- TY4131: Upright 8.0K, 3/4",NPT Always refer to Technical Data facturershould'be contacted with any TY4231: Pendent 8.0K, 3/4" NPT . Sheet TFP700 for the "INSTALLER questions. TY4831: Upright* 8.0K, 1/2" NPT WARNING" that provides cautions TY4931: Pendent* 8.0K, 1/2" NPT • with respect to handling • and installation of sprinkler systems and components. Improper handling and • _ installation .can.permanently_damage_ a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. 'Eastern Hemisphere Sales Only Page 1 of 10 JULY 2010 TFP171 1 TFP171 Page 2 of 10 7/16" (11,1 mm) ESCUTCHEON STYLE 10 or 20 * NOMINAL PLATE SEATING RECESSED SSU 1/2 MAKE -IN SURFACE ESCUTCHEON • DEFLECTOR NPT 6* -' �1•� *`"EtaN to tilt r - - -i it } 5 I — `` 7/16" o 4 l(11,1 mm) } .� 2 1/4" ^1��� I NOMINAL „,,n. 1 (57,2 mm) ����- 2 ir MAKE -IN Ire 3 2- 3/16” 1-9/16" (55,6 mm) ! WRENCH (39.7 mm) 4$ 1 I FLATS 1, 1/2" NPT SSP DEFLECTOR -- 2 -7/8" (73,0 mm) DIA. -- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector • Assembly • Temperature rating is indicated on deflector or adjacent to . 2 - Button 5 - Com 7 - Bushing orifice seat on frame. Screw FIGURE 1. • QUICK RESPONSE SERIES TY-FRB .UPRIGHT (TY1131) AND PENDENT (TY/231) SPRINKLERS 2.8.K- FACTOR, 1/2 INCH NPT • • • 7/16" (11,1 mm) ESCUTCHEON STYLE 10 or 20 * NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE -IN NP SURFACE ESCUTCHEON 6 * b'vTt'14 *�/TT7w� / / r \� I � 5 `�� 7/16.. 1 � (11,1 mm) f 2- 3/16" iI�r- 4 ; I NOMINAL • i„,41. (55,6 mm) ���� MAKE IN 1 2 V 2 3/16" I I 1 1/2 �I� 1 (5 5,6 mm) + WRENCH (38.1 mm) 3 'jam' � _ FLATS - - 1 1 f 1/2" NPT SSP DEFLECTOR 2 -7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly ' Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K- FACTOR, 1/2 INCH NPT • • • • • TFP171 Page 3 of 10 7/16" (11,1 mm) ESCUTCHEON STYLE 10 or 20 * NOMINAL PLATE SEATING RECESSED SSU 1/2 MAKE -IN SURFACE ESCUTCHEON • • DEFLECTOR NPT I 5 -----.!• 7/16" I — (11,1 mm) f / 2- 3/16" ��1! 4 li NOMINAL 0fri (55,6 mm) � MAKE -IN 7 2 , 3' (52-3/16" . ) 1 O L I , ,/ � • 3 �• WRENCH (38,1 mm) �— FLATS - _'/ 1/2" NPT SSP DEFLECTOR -- 2 -7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector • Assembly • Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw • • FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT 1/2" (12,7 mm) ESCUTCHEON STYLE 30 or 40 SSU * NOMINAL 3/4" PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 1 I 7 5 1E! 1/2" ,=== img I (12,7 mm) f 2 5/16" 4 ' I NOMINAL 0 2 VTI , -9/(58,7 mm) , MAKE IN 1 ` �'� � lir — 101 2 -1/4" I ,6" �I � 3 (57,2 mm) + (39, 7 mm) li i -- ------- --,..—=---- V i I 3/4" NPT SSP DEFLECTOR 2 -7/8" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly • Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. • Screw • • FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS - , 8.0 K- FACTOR, 3/4 INCH NPT • • • .TFP171 Page 4 of 10 7/16" (11,1 mm) SSU NOMINAL 1/2" DEFLECTOR MAKE -IN NPT 6 1 i 5 t� 7/16" 2 -1/4" li NOMINAL NA L 01 111/II (57,2 mm) 4 N MAKE -IN : 2- 3/16" r` 1- 9/16 (55,6 mm) o WRENCH (39,7 mm) I FLATS 1 f 1 ssP * CROSS 1/2 NPT DEFLECTOR SECTION UPRIGHT PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Assembly ' Temperature rating is indicated on deflector or adjacent to 2 - Button 5 - Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS ' 8.0 K- FACTOR, 1/2 INCH NPT Technical Operation inch (1,6 mm) for the 135 °F /57 °C and I" 3/32 inch (2,4 mm) for the 286 °F /141 °C Data The glass Bulb contains a fluid that temperature ratings. expands when exposed to heat. When Obtain a leak -tight 1/2 inch NPT sprin- Approvals the rated temperature is reached, the kler joint by applying a minimum to UL and C -UL Listed fluid expands sufficiently to shatter the maximum torque of 7 to 14 ft.lbs. (9,5 FM, LPCB, and NYC Approved glass Bulb, allowing the sprinkler to to 19,0 Nm). Higher levels of torque . Refer to Table A and B for complete - activate and water to flow. can distort the sprinkler Inlet with con - approval information including . • Sequent leakage or impairment of the corrosion - resistant status. Design • sprinkler. Maximum Working Pressure /� Do not attempt to compensate for Refer to Table C. Criteria • insufficient adjustment in the Escutch- eon Plate by under- or over - tightening . Discharge Coefficient The TYCO Series TY -FRB Pendent the sprinkler. Re- adjust the position of K =2.8 GPM /psi (40,3 LPM /bar,/ and Upright Sprinklers are intended the sprinkler fitting to suit. K =4.2 GPM /psi / (60,5 LPM /bars "2) for fire protection systems designed in The Series TY -FRB Pendent and K =5.6 GPM /psi'� (80,6 LPM /bart�2 accordance with the standard' installs- ) tion rules recognized by the applicable Upright Sprinklers must be installed K =8.0 GPM /psilI (115,2 LPM /bar1'2) Listing or Approval agency (such as, UL in accordance with the following Listing is based on the requirements of instructions.. Temperature Rating NFPA 13, and FM Approval is based on 1. Install Pendent sprinklers in the Refer to Table A and B. the requirements of FM's Loss Preven- pendent position. Install upright Finishes tion Data Sheets). Only the Style 10, sprinklers in the upright position. Sprinkler: Refer to Table A and B. 20, 30, or 40 Recessed Escutcheon, as 2: With pipe- thread sealant applied to • Recessed Escutcheon: White Coated, applicable, is to be used for recessed the pipe threads, hand - tighten the. Chrome Plated, or Brass Plated. pendent installations. sprinkler into the sprinkler fitting. Physical Characteristics Installation 3. Tighten the sprinkler into the sprin- Frame Bronze kler fitting using only the W-Type 6 • Button Brass /Copper The TYCO Series TY -FRB Sprinklers Sprinkler Wrench (Figure 14). With Sealing Assembly Beryllium must be installed in accordance with reference to Figures 1 through . Nickel w/Teflont the following instructions. 5, apply the W -Type 6 Sprinkler Bulb Glass Wrench to the sprinkler wrench Compression Screw Bronze NOTICE flats. Deflector Copper /Bronze - - -. - -- Bushing- (K= 2.8) -. -:- . -. —.— Bronze--- Do.not.install-any.bulb- type- sprinkler_if -- —_ _________ ___ —___ the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter t Registered Trademark of Dupont of the air bubble is approximately 1/16 TFP171 Page 5 of 10 • SPRINKLER FINISH (See Note 5) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME WHITE*** FACTOR COLOR BRASS PLATED POLYESTER 135 °F /57 °C Orange PENDENT 155Ff68°C Red (TY1231) and 175 °F /79 °C Yellow 1, 2, 3, 4 UPRIGHT (TY1131) 200 °F /93 °C Green 286 °F /141 °C Blue • 135 °F /57 °C Orange 2.8 RECESSED 155 °F /68 °C Red 1/2" NPT PENDENT (TY1231)" 175F/79°C Yellow Figure 6 20OF/93°C . Green 1,2,4 135 °F /57 °C Orange RECESSED PENDENT . 155°F/68°C Red (TY1231)" 175F/79°C Yellow Figure 7 200 °F /93 °C Green • 135 °F /57 °C . Orange • PENDENT 155F/68°C Red • ' and 175 °F /79'C Yellow UPRIGHT (TY2131) 200 °F /93 °C • Green 286 °F /141 °C Blue 135 °F /57 °C Orange 4.2 RECESSED 1/2" NPT PENDENT 155 °F /68 °C Red 1.2 (TY2231)' 175 °F /79 °C Yellow Figure 8 200 °F /93 °C Green • • 135 °F /57 °C Orange RECESSED 1 55 °F /68 °C Red PENDENT . (TY2231)** 175 °F /79 °C Yellow Figure 9 200 °F /93 °C Green NOTES: • • 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354 -01 -E. 5. Where Polyester Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion- Resistant Sprinklers. ' Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. " Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. • Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available • TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K- FACTOR SPRINKLERS • • • • TFP171 Page 6 of 10 SPRINKLER FINISH (See Note 8) • K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME WHITE * ** LEAD .FACTOR COLOR BRASS PLATED POLYESTER COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY3231) and 175 °F /79 °C Yellow 1.2, 3, 4, 5, 6, 7 1, 2, 3, 5 UPRIGHT 200 °F /93 °C Green (TY3131) 286F/141°C Blue 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red 5.6 PENDENT 175 °F /79 °C Yellow 1, 2, 4, 5 N/A 1/2" NPT (TY3231)* Figure 10 200 °F /93 °C Green 286 °F /141 °C Blue 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 175 °F /79 °C Yellow 1, 2, 3, 4, 5 N/A (TY3231) ** Figure 11 200 °F /93 °C . Green • • 286 °F /141 °C Blue 135 °F /57 °C Orange PENDENT (TY4231) 155 °F /68 °C Red and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7 1,2,5 UPRIGHT 20OF/93°C Green (TY4131) 286 °F /141 °C Blue • 135 °F /57 °C Orange RECESSED 155F/68°C Red 8.0 PENDENT 175 °F /79 °C Yellow 1, 2, 5 N/A 3/4" NPT (TY4231)* Figure 12 200 °F /93 °C Green • 286 °F /141 °C Blue 135F/57°C Orange RECESSED 155fF/68°C Red PENDENT 175F/79°C Yellow 1, 2, 3, 5 N/A (TY4231) ** Figure 13 200F/93°C Green 286 °F /141 °C Blue 135 °F /57 °C Orange PENDENT • 155 °F /68 °C Red 8.0 (TY4931) 1/2" NPT and 175 °F /79 °C . Yellow 1, 2, 4, 5, 6 1, 2, 5 UPRIGHT 200 °F /93 °C Green (TY4831) 286 °F /141 °C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C -UL) as Quick Response Sprinklers. • 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. • 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31 -53- 428- 4444/Fax 31 -53- 428- 3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead - Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion - Resistant Sprinklers. Where Lead - Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion - Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. *'* Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available • - - - -- - - - -- - -- TABLE -- - - -- - - - -- - - -- LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K- FACTOR SPRINKLERS • • • • • • TFP171 _. . .. Page 7of.10.: .....,.: • SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD . FACTOR BRASS PLATED POLYESTER COATED PENDENT (TY1231) and UPRIGHT (TY1131) 2.8 1/2" NPT 75 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY2231) PENDENT (TY3231) 175 PSI and (12,1 BAR) 5.6 UPRIGHT (TY3131) 250 PSI (17,2 BAR) 1/2" NPT — OR 175 PSI (12,1 BAR) • RECESSED (SEE NOTE 1) N/A PENDENT (TY3231) • PENDENT (TY4231) 175 PSI and (12,1 BAR) 8.0 UPRIGHT (TY4131) • 3/4" NPT 175 PSI (12,1 BAR) — RECESSED N/A PENDENT (TY4231) PENDENT (TY4931) PSI 8.0 1/2" NPT and 175 PSI (12,1 BAR) (121 BAR) UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc..for use in. Canada (C -UL); and, the Approval by the City of New York. . . • TABLE C MAXIMUM WORKING PRESSURE The Series TY -FRB Recessed Pendent Care and Exercise care to avoid damage to Sprinklers must be installed in accor- sprinklers before, during, and after dance with the following instructions. Maintenance installation. Never paint, plate, coat, 1. After installing the Style 10, 20, 30, or otherwise alter automatic sprinklers or 40 Mounting Plate, as applica- The TYCO Series TY -FRB must be after they leave the factory. ble, over the sprinkler threads and maintained and serviced in accordance Replace sprinklers that: with pipe- thread sealant applied to with the following instructions. • were modified or over - heated. • the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. • were damaged by dropping, striking, NOTICE wrench twisting, wrench slippage, or ' 2. Tighten the sprinkler into the sprin- Before closing afire protection system • the like. • . kler fitting using only the W-Type 7 main control valve for maintenance • are leaking or exhibiting visible signs Recessed Sprinkler Wrench (Fig - work on the fire protection system of corrosion.. g g ure 15). With reference to Figures 1 that it controls, obtain permission to to 4, apply the W-Type 7 Recessed shut down the affected fire protection • were exposed to corrosive products • Sprinkler Wrench to the sprinkler sys from the proper authorities of combustion but have not oper- wrench flats. and notify all personnel who may be ated, if you cannot easily remove 3. After ceiling installation and finish- affected by this action. combustion by- products with a cloth. ing, slide on the Style 10, 20, 30, or Absence of . the outer piece of an • have a cracked bulb or have lost liq- 40 Closure over the Series TY -FRB _ which- used -.to -cover uid from the_bulb._Refer-to_the_Instal- Sprinkler and push the Closure over a clearance hole, can delay sprinkler lation section in this data sheet. the Mounting Plate until its flange operation in a fire situation. comes in contact with the ceiling. • • • • • • TFP171 • Page 8of10 . . • 2 -7/8" DIA. 2 -7/8" DIA. _ 5/8 ±1/4" ( mm) 3/4" (19,1 mm) - 1/2 ±1/8" (73,0 mm) 1/2" (12,7 mm) (15,9 ±6,4 mm) 1/4" (6,4 mm) (12,7 ±3,2 mm) 1/4" (6,4 mm) 2 -1/4" DIA. 2 -1/4" DIA. FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / 1/8" � 1/8" m ' (3,2 mm) 7 . . 1 (3,2 mm) } \ AIMPigi' ".• ; , � I ` , MOUNTING VS t MOUNTING t SURFACE SURFACE ��!„�,� "eprr� CLOSURE SERIES 1-5/16" (33,3 mm) CLOSURE SERIES 1- 5/16" (33.3 mm) TY -FRB 13/16" (20.6 mm) TY-FRB 1- 1/16" (27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON • 2.8 K- FACTOR, 1/2 INCH NPT 2.8 K- FACTOR, 1/2 INCH NPT 2 -7/8" DIA. 2 -7/8" DIA. 5/8 ±1/4" (73,0 mm) 3/4 (19,1 mm ) 1/2 ±1/8" • (73,0 mm) 1/2" (12,7 mm) (15,9 ±6,4 mm) 2 -1/4" DIA. 1/4 "(6,4 mm) (12,7±3.2 mm) 2 -1/4" DIA. 1/4 "(6,4 mm) FACE OF . (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER // / PLATE FITTING FITTING 1/8" 1/8" l � ' i (3,2 mm) _ (3,2 mm) Jl f M. E�∎_ = } A ri j n rur ra, MOUNTING IF } MOUNTING } SURFACE SURFACE . - - -- -- •--- -- - -•• ' • CLOSURE SERIES 1 -1/4" (31,8 mm) CLOSURE SERIES 1 -1/4" (31,8 mm) TY -FRB 3/4" (19.1 mm) TY -FRB 1" (25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K- FACTOR, 1/2 INCH NPT 4.2 K- FACTOR, 1/2 INCH NPT • Initial and frequent visual inspections of Responsibility lies with the owner for Care must be exercised to avoid dam - random samples are recommended for the inspection, testing, and mainte- age to the sprinklers - before, during, corrosion- resistant sprinklers to verify nance of their fire protection system and after installation. Sprinklers dam- the integrity of the corrosion - resistant and devices in compliance with this aged by dropping, striking, wrench material of construction. Thereafter, document, as well as with the appli- twist /slippage, or the like, must . be annual inspections per NFPA 25 should cable standards of the National Fire replaced. Also, replace any sprinkler suffice. Protection Association (for example, that has acracked bulb or that has lost Inspections of corrosion- resistant NFPA 25), in addition to the standards liquid from its bulb. (Ref. Installation sprinklers are recommended at close of any other authorities having jurisdic- . Section). • range, instead of from the floor level lion. Contact the installing contractor or Initial and frequent visual inspections of per NFPA. Inspection at close range sprinkler manufacturer regarding any random samples are recommended for can better determine the exact sprin- questions. corrosion- resistant sprinklers to verify - - - -- kler and =terminteg= - -- Automatic - sprinklersystems - are - the - integrity - of the resistant - - -- - -- • rity of the corrosion - resistant material, ommended to be inspected, tested, material of construction. Thereafter, which can be affected by the corrosive and maintained by a qualified Inspec- annual inspections per NFPA 25 should conditions present. tion Service in accordance with local suffice. requirements and /or national codes. • TFP171 Page 9 of 10 2 -7/8" DIA. 2 -7/8" DIA. _ 5/8 ±1/4" (73,0 mm) - 3/4" (19,1 mm) 1/2 ±1/8" (73.0 mm) 1/2" (12,7 mm) (15,9 ±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7 ±3,2 mm) 1/4" (6,4 mm) 2 -1/4" DIA. FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) SPRINKLER MOUNTING FITTING P LATE SPRINKLER FITTING INKL R PLATE / 1/8" 1/8° .. ( 3,2 mm) ■.� (3,2 mm) MOUNTING 1 �' AME,ti w MOUNTING N , SURFACE 1 SURFACE -,-...=---,-- , - -- i / CLOSURE SERIES 1 -1/4" (31,8 mm) CLOSURE SERIES 1 -1/4" (31.8 mm) TY -FRB 3/4" (19,1 mm) TY -FRB 1" (25,4 mm) FIGURE 10 FIGURE 11 SERIES 7Y-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT 5.6 K- FACTOR, 1/2 INCH NPT • 2 -7/8" DIA. 2 -7/8" DIA. -y 5/8 ±1/4" (73,0 mm) 3/4" (19,1 mm) 1/2±1/8" _ (73,0 mm) 1/2" (12,7 mm) (15,9 ±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER _______.-- SPRINKLER PLATE FITTING FITTING 1/8" 1/8" u (3,2 mm) n ( 3.2 1 mm) • DUI / � 1 - i L � , t MOUNTING lir MOUNTING �• SURFACE SURFACE � . CLOSURE SERIES 1- 5/16" (33,3 mm) CLOSURE SERIES 1- 5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) TY-FRB 1- 1/16" (27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES 7Y-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON . 8.0 K- FACTOR, 3/4 INCH NPT 8.0 K- FACTOR, 3/4 INCH NPT Inspections of corrosion- resistant WRENCH sprinklers are recommended at close el • RECESS range, instead of from the floor level per NFPA. Inspection at close range WRENCH RECESS • / can better determine the exact sprin- (END "A" USED FOR Orli kler condition and the long -term integ- 1/2" NPT MODELS) rity the corrosion-resistant the iv w which h be affected can be affected ed bby the corrosive ■ conditions present. WRENCH RECESS (END "B" USED FOR 4 t . 3/4" NPT MODELS) PUSH WRENCH IN TO - -- -- - -- - - -- - -- -- - ENSURE - WITH - - FIGURE 14 SPRINKLER WRENCHING AREA W -TYPE 6 SPRINKLER FIGURE 15 WRENCH W -TYPE 7 RECESSED • SPRINKLER WRENCH • TFP171 Page 10 of 10 P/N 57 - XXX - X - XXX I I MODEL/SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT (1/2 "NPT) TY1131 1 NATURAL BRASS 135 135 °F (57 °C) 331 2.8K PENDENT (1/2 "NPT) TY1231 4 WHITE POLYESTER 155 155 °F (68 °C) 340 4.2K UPRIGHT (1/2 "NPT) TY2131 3 WHITE (RAL9010)' 175 175 °F (79 °C) 341 4.2K PENDENT (1/2 "NPT) TY2231 9 CHROME PLATED 200 200 °F (93 °C) 370 5.6K UPRIGHT (1/2 "NPT) TY3131 7 LEAD COATED 286 286 °F (141 °C) 371 5.6K PENDENT (1/2 "NPT) TY3231 • 390 8.0K UPRIGHT (3/4 "NPT) TY4131 . 391 8.0K PENDENT (3/4 "NPT) TY4231 360 8.0K UPRIGHT (1/2 "NPT) TY4831' " Eastern Hemisphere sales only. 361 8.0K PENDENT (1/2 "NPT) TY4931' • TABLE D PART NUMBER SELECTION SERIES,TY -FRB PENDENT AND UPRIGHT SPRINKLERS • . Limited • responsible for sprinkler system design Ordering . 'errors or inaccurate or incomplete infor- 7 Warrant mation supplied by Buyer or Buyer's Procedure Y representatives. Products manufactured by Tyco Fire In no event shall TFSBP be liable, in Contact your local distributor for Suppression & Building Products contract, tort, strict liability or under availability. When placing an order, (TFSBP) are warranted solely to the any other legal theory, for incidental, . indicate the full product name and Part original Buyer for ten (10) years against indirect, special or consequential dam- Number (P /N). defects in material and workmanship ages, including but not limited to labor when paid for and properly installed charges, regardless of whether TFSBP Sprinkler Assemblies with NPT and maintained under normal use and was informed about the possibility of Thread Connections service. This warranty will expire ten such damages, and in no event shall (10) .years from date of shipment by TFSBP's liability exceed an amount Specify: (Specify Model/SIN), fa tr), (specify Quick y TFSBP. No warranty is given for prod- t Response, r atiny , Seri (specify equal • ucts or components manufactured by l to the sales price. _ temperatu ture rating), Series TY -FRB companies not affiliated by ownership The foregoing warranty is made in lief{ (specify Pendent or Upright) Sprinkler with TFSBP or for products and corn- of any and all other warranties. express with (specify type of finish or coating), ponents which have been subject to or implied, including warranties of mer- P/N (specify from Table D). . misuse, improper installation, corro- chantability and fitness for a particular Recessed Escutcheon: . sion, or which have not been installed, purpose. Specify: Style (10, 20, 30, or 40) . maintained, modified or repaired in This limited warranty sets forth the Recessed Escutcheon with (specify ") . accordance with applicable Standards exclusive remedy for claims based on finish, P/N (specify"). of the National Fire Protection Associa- failure of or defect in products, materi- tion, and /or the standards of any other als or components, whether the claim is Sprinkler Wrench Authorities Having Jurisdiction. Mate- made in contract, tort, strict liability or Specify: W -Type 6 Sprinkler Wrench, • rials found by TFSBP to be defective any other legal theory. P/N 56- 000 -6 -387. shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither This warranty will apply to the full Specify: W -Type 7 Sprinkler Wrench, assumes, nor authorizes any person extent permitted by law. The invalidity, P/N 56- 850 -4 -001. to assume for itany other obligation'in —in whole or part, -of any portion Of •this— — Refer to T echnical Data Sheet TFP 770. • connection with the sale of products or warranty will not affect the remainder. . parts of products. TFSBP shall not be ' Copyright © 2007 -2010 Tyco Fire Suppression & Building Products. All rights reserved.