Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
FP5 Zo J o a�ro 7© 977 Was 7 I a s L . Sebs PG` / pog Attica Fire & Building Products - , � ' ` �' �`' JUN 2 4 2010 Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 ®,� BU1LD11�'C DI` / 15➢PW Series TY -FRB — 2.8, 4.2, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage mospheres. Although corrosion resis- General tant coated sprinklers have passed the .w ,, standard corrosion tests of the appli- ���` Description cable approval agencies, the testing is - not representative of all possible cor- "j The Series TY -FRB, 2.8, 4.2, 5.6, and rosive atmospheres. Consequently, it f 8.0 K- factor, Upright and Pendent is recommended that the end user be J Sprinklers described in this data sheet consulted with respect to the suitability ,� are quick response - standard cover- of these coatings for any given corro- l'l age, decorative 3 mm glass bulb type sive environment. The effects of ambi- ; - — spray sprinklers designed for use in ent temperature, concentration of light or ordinary hazard, commercial chemicals, and gas /chemical velocity, _ t occupancies such as banks, hotels, should be considered, as a minimum, .- shopping malls, etc. along with the corrosive nature of the • chemical to which the sprinklers will be The recessed version of the Series exposed. �'� TY-FRB Pendent Sprinkler, where ap- ,\ plicable, is intended for use in areas An intermediate level versions of the with a finished ceiling. It uses either a Series TY -FRB Pendent Sprinklers are two -piece Style 10 (1/2 inch NPT) or detailed in Technical Data Sheet i Style 40 (3/4 inch NPT) Recessed Es- TFP356, and Sprinkler Guards are de- r cutcheon with 1/2 inch (12,7 mm) of tailed in Technical Data Sheet TFP780 recessed adjustment or up to 3/4 inch ' ,� �� (19,1 mm) of total adjustment from the WARNINGS . flush pendent position, or a two -piece The Series TY - FRB Sprinklers de Style 20 (1/2 inch NPT) or Style 30 (3/4 scribed herein must be installed and � inch NPT) Recessed Escutcheon with maintained in compliance with this 1/4 inch (6,4 mm) of recessed adjust- document, as well as with the applica- ment or up to 1/2 inch (12,7 mm) of ble standards of the National Fire Pro TY3231 - Pendent 5.6K, 1/2 "NPT total adjustment from the flush pen- tection Association, in addition to the TY4131 - Upright 8.0K, 3/4 "NPT dent position. The adjustment provided standards of any other authorities hay TY4231 - Pendent 8.0K, 3/4 "NPT by the Recessed Escutcheon reduces ing jurisdiction. Failure to do so may the accuracy to which the fixed pipe impair the performance of these de- Technical drops to the sprinklers must be cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain- Data applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. Approvals that which would otherwise be ob- The installing contractor or sprinkler A d C s Listed. an tamed when exposed to corrosive at- manufacturer should be contacted U L n dC - and NYC Approved. with any questions. (Refer to Table A for complete approval IMPORTANT information including corrosion resis- Always refer to Technical Data tant status.) Sheet TFP700 for the "INSTALLER Model /Sprinkler Maximum Working Pressure WARNING" that provides cautions - - 175 psi (12,1 bar) with respect to handling and instal- Identification Discharge 2 Coefficient pon n ents. Im andli and and in- N umbers K = 2.8 GPM /psi (40,3 LPM /bar at po llafio k can permanently an and damage K = 4.2 GPM /psi (60,5 LPM /bar a sprinkler system or iy ge sprinkler its compo TY1131 - Upright 2.8K,1/2 " NPT K = 5.6 GPM /psi (80,6 LPM /bars vents and cause the sprinkler to fail TY1231 - Pendent 2.8K, 1/2 "NPT K = 8.0 GPM /psi (115,2 LPM /bar1' ) to operate in a fire situation or cause TY2131 - Upright 4.2K, 1/2"NPT Temperature Ratings it to operate prematurely. TY2231 - Pendent 4.2K, 1/2"NPT Refer to Table A and B TY3131 - Upright 5.6K, 1/2"NPT Page 1 of 8 JULY, 2004 TFP171 • Page 2 of 8 TFP171 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING „ * * NOMINAL RECESSED SSU* • SURFACE f V P T MAKE -IN ESCUTCHEON DEFLECTOR 6 _ 5 �r 7/16" .� -� �1' (11 mm) I I 4 (57,2 mm) 0 r A NOMINAL - i t 111 MAKE IN A 2 I" I 11=1111 I 2-3/16" t � 3 (39,7 I WRENCH i (55,6 mm) Ole 1 SSP DEFLECTOR - 2 -7/8" (73,0 mm) DIA. 1/2" NPT ** f -: PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame.' • Screw ' * *pipe thread connections per ISO 7/1 can be provided on • special request. . FIGURE I QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2:8 K- FACTOR, 1/2 INCH NPT ' ESCUTCHEON 7/16° (11,1 mm) STYLE 10 or 20 . PLATE SEATING 1/2° ** NOMINAL RECESSED SSU* V • SURFACE NPT MAKE -IN ESCUTCHEON DEFLECTOR 6 6* r " •' 5 2- 3/16° I V .(11 1 mm) I (55,6 mm) I r I' M AKE AN 1 -1/2° � I i 4 I �' 2 ��� l 2 -3/16" (38,1 mm) Al O WRENCH � I 1 (55,6 mm) 4 1 S - -- • FLATS 1 1 i 3 1 • SSP DEFLECTOR * 2 -7/8° (73,0 mm) DIA. 1/2° NPT PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. • Screw ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K- FACTOR, 1/2 INCH NPT , y4 . „ _ ' E V Finishes Bulb Glass 0 perafion Sprinkler: Refer to Table A and B Compression Screw Bronze m Recessed Escutcheon: White Coated, Deflector . . . . . . . Copper /Bronze Chrome Plated, or Brass Plated Bushing (K =2.8) Bronze The glass Bulb contains a fluid which m expands when exposed to heat. When y - -- - -- the - rated - temperature- is- reached,_the —__ -m Physical Character fluid expands sufficiently to shatter the cc Frame Bronze glass Bulb, allowing the sprinkler to 0 Button Brass /Copper • activate and water,to flow. • Sealing Assembly - = Beryllium Nickel w/Teflont } • TFP171 Page 3 of 8 . ESCUTCHEON 7/16° (11,1 mm) STYLE 10 or 20 PLATE SEATING 1/2° ** NOMINAL RECESSED SSU* - SURFACE NPT MAKE -IN' ESCUTCHEON DEFLECTOR 6 1° 3 • 5 2-3/16" �rr 7/16 �'•''`�� (11,1 mm) I � � A - 1 ._- I NOMINAL i 4 (55,6 mm) 1 MAKE IN w I 1 -1/2° I Mt I ♦ter 2 3/1 6" 2 • (38,1 mm) WRENCH 1 (55,6 mm) ,� - 3 1 ,_ -• _ A — FLATS '�i SSP DEFLECTOR - 2 -7/8° (73,0 mm) DIA. 1/2" NPT f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. . Screw ** Pipe thread connections per ISO 7/1 can be provided on special request. FI 3 QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT ESCUTCHEON . 1/2° (12,7 mm) STYLE 30 or 40 PLATE SEATING 3/4° ...k NOMINAL RECESSED SSU* SURFACE NPT MAKE -IN ESCUTCHEON DEFLECTOR i \ -_,.------------_ ..-----___ 1/2° S 2 -5/16° `�I.� (12,7 mm) i (58,7 mm) � MAKE -IN 1 -9/16" lit I 1 2 -1/4° Y V i _' .. . ' • . . -. (39,7 mm) 111 • WRENCH' (57,2 mm) �' II FLATS 1 R * 2 -7/8° (73,0 mm) DIA. • 3/4° NPT SSP DEFLECTOR PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw ** Pipe thread connections per ISO 7/1 can be provided on • special request. FIGURE 4 . QUICK RESPONSE SERIES TY -FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT Listing is based on the requirements of Design NFPA 13, and FM Approval is based Installation on the requirements of FM's Loss Pre - Criteria vention Data Sheets ). Only the Style The Series TY -FRB Sprinklers must be 10, 20, 30, or 40 Recessed Escutch- installed in accordance with the follow - The Series TY -FRB Pendent and eon, as applicable, is to be used-for ing -- ` right Sprinklers are intended for fire recessed pendent installations. NOTES . protection systems designed in ac- cordance with the standard installation . Do not install any bulb type sprinkler if rules recognized by the applicable the bulb is cracked or there is a loss of •• Listing or Approval agency (e.g., UL liquid from the bulb. With the sprinkler • • Page 4 of 8 TFP171 SPRINKLER FINISH (See Note 7) inch NPT sprinkler joint should be ob- K TYPE TEMP. BULB NATURAL CHROME WHITE *" tained with a torque of 10 to 20 ft.lbs. • LIQUID BRASS PLATED POLYESTER (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used 135 °F /57 °C Orange to install sprinklers with 3/4 NPT con - g nections. Higher levels of torque may PENDENT • 155 Red distort the sprinkler inlet and cause (TY1231) - 1, 2, 3, 5 leakage or impairment of the sprinkler. and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green Do not attempt to make -up for insuffi- (TY1131) cient adjustment in the escutcheon 2.8 286 °F /141 °C Blue plate by under- or over - tightening the 1/2° sprinkler. Readjust the position of the NPT 135 °F /57 °C Orange sprinkler fitting to suit. RECESSED 155 °F /68 °C Red PENDENT The Series TY -FRB Pendent and Up- (TY1231)* 175 °F /79 °C Yellow right Sprinklers must be installed in Figure 5 200 °F /93 °C Green 1, 2, 5 accordance with the following instruc- tions. 135 °F /57 °C Orange Step 1. Pendent sprinklers are to be RECESSED 155 °F /68 °C Red installed in the pendent position, and PENDENT - upright sprinklers are to be installed in (TY1231) ** 175 °F /79 °C Yellow the upright position. Figure 6 200 °F /93 °C Green • - Step 2. With pipe thread sealant •p- 135 °F /57 °C Orange plied to the pipe threads, hand tighten PENDENT the sprinkler into the sprinkler fitting. • 155 °F /68 °C • Red (TY2231) Step 3. Tighten the sprinkler into the and . 175 °F /79 °C Yellow sprinkler fitting using only the W -Type UPRIGHT 200 °F /93 °C Green 6 Sprinkler Wrench (Ref. Figure 13). (TY2131) With reference to Figures 1, 2, 3, and 4.2 286 °F /141 °C Blue 2 4, the W -Type 6 Sprinkler Wrench is to 1/2° be applied to the sprinkler wrench NPT 135 °F /57 °C Orange flats. RECESSED 155 °F /68 °C Red PENDENT (TY2231)* 175 °F /79 °C Yellow The Series TY - FRB Recessed Pen- . Figure 7 200 °F /93 °C Green dent Sprinklers must be installed in accordance with the following instruc- 135°F/57°C Orange tions. RECESSED Red Step A. After installing the Style 10. PENDENT 20, 30, or 40 Mounting Plate, as appli- (TY2231)** 175 °F /79 °C Yellow cable, ever the sprinkler threads and Figure 8 200 °F /93 °C Green • -.. -„ • • . with pipe thread sealant applied to the . pipe threads, hand tighten the sprin- . NOTES: kler into the sprinkler fitting. 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Step B. Tighten the sprinkler into the 2. Listed by Underwriters Laboratories,'Inc. for use in Canada (C -UL) as Quick Response sprinkler fitting using only the W -Type Sprinklers. 7 Recessed Sprinkler Wrench (Ref. klers. . A proved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- Figure 14). With reference to Figure 1, 5. Approved by the City of New York under MEA 354 -01 -E. 2, 3, and 4, the W -Type 7 Recessed 7. Where Polyester Coated Sprinklers are noted to be UL and C -UL Listed, the sprin- Sprinkler Wrench is to be applied to klers are UL and C -UL Listed as Corrosion Resistant Sprinklers. the sprinkler wrench flats. ' Installed with Style 10 (1/2° NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Step C. After the ceiling has been in- Recessed Escutcheon, as applicable. stalled or the finish coat has been ap- Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment plied, slide on the Style 10, 20, 30, or Recessed Escutcheon, as applicable. 40 Closure over the Series TY-FRB "" Frame and Deflector only. Listings and approvals apply to color (Special Order). Sprinkler and push the Closure over N /A: Not Available P P TABLE A the Mounting Plate until its flange • LABORATORY LISTINGS AND APPROVALS comes in contact with the ceiling. 2.8 AND 4.2 K- FACTOR SPRINKLERS held h o i i z o n t a l l y , a small air b bble A I n a k t i g f i n / 2 inch NPT sprii klerjoint -- — -- — - -- — -- " "" "-"` should be present. The diameter of the should be obtained with a torque of 7 air bubble is approximately 1/16 inch to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- (1,6 mm) for the 135 °F /57 °C to 3/32 mum of 21 ft. lbs. (28,5 Nm) of torque inch (2,4 mm) for the 286 °F /141 °C • may be used to install sprinklers with . . temperature ratings. 1/2 NPT connections. A leak tight 3/4 • TFP171 Page 5 of 8 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LEAD _ • LIQUID BRASS PLATED POLYESTER COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red • (TY3231) 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green 5.6 (TY3131) 286 °F /141 °C Blue 1/2" NPT 135F/57°C Orange RECESSED 155F/68°C Red PENDENT 1, 2, 4, 5 N/A (TY3231)* 175 °F /79 °C Yellow Figure 9 200 °F /93 °C Green • 135 °F /57 °C Orange RECESSED 155F/68°C Red PENDENT 1, 2, 3, 4, 5 1, 2, 4, 5 N/A (TY3231)•' 175 °F /79 °C Yellow . Figure 10 200 °F /93 °C Green • . ' 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY4231) 1, 2, 5 and 175 °F /79 °C Yellow 1, 2, 3; 4, 5, 6, 7 UPRIGHT • 200 °F /93 °C Green • 8.0 (TY4131) 286 °F /141 °C Blue 3/4" NPT 135 °F /57 °C Green RECESSED 155 °F /68 °C Orange PENDENT 1, 2, 4, 5 N/A (TY4231)' 175 °F /79 °C Red Figure 11 200 °F /93 °C Yellow 135 °F /57 °C Orange • • RECESSED 155 °F /68 °C Red • PENDENT 1, 2, 3, 4, 5 . N/A (TY4231)'• 175 °F /79 °C .Yellow. Figure 12 200 °F /93 °C Green - - - °• .' NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters, Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporationf(FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. , 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31 -53- 428- 4444/Fax 31 -53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as ' Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a . Corrosion Resistant Sprinklers. • Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. • Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2° Total Adjustment Recessed Escutcheon, as applicable. "' Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE B • LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K- FACTOR SPRINKLERS • • Page 6 of 8 TFP171 2 -7/8' DIA. 2 -7/8° DIA. (73,0 mm) 1/2° (12,7 mm) 5/8±1/4° (73,0 mm) 3/4'(19,1 mm) 1/2±1/8' (15,9±6,4 m 2 -1/4' DIA. 1/4' (6,4 mm) (12,7±3,2 mm) 2 -1/4' DIA. 1/4° (6,4 mm) . (572 mm) FACE OF (57.2 mm) MOUNTING FACE OF , MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8° 1/8° +a (3,2 mm) +� (3,2 mm) 1 Al _, M M 11W / I \ , ` ,� ' SURFACE I r MOUNTING 1 SURFACE ,pp-."NC,. ' , r • M • 1 -5/16° (33,3 mm) SERIES 1 -5/16° (33,3 mm) CLOSURE SERIES CLOSURE TY -FRB 13/16° (20,6 mm) TY -FRB 1 -1/16° (27,0 mm) • FIGURE 5 FIGURE 6 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT • STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K- FACTOR, 1/2 INCH NPT • 2.8 K- FACTOR, 1/2 INCH NPT • 2 7/ 8° DIA. 2 -7/8° DIA. -7/8 5/8±1/4° (73,0 mm) - . 3/4° (19,1 mm) 1/211/B' mm) 1/2' (12,7 mm) (15,9±6,4 mm ) 2 -1/4° DIA. 1/4° (6,4 mm) (12,7±3,2 mm) 2 -1/4° DIA. 1/4° (6,4 mm) FACE OF -1/4 mm) MOUNTING (57,2 mm) FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING . I 1/8' 1/8° +t (3 mm) -Willi ( mm) 1 1 -1011 ii,• yry ��� � `=� MOUNTING VP } SURFAC MOUNTING .. it I ___. , SURFACE -- SERIES 1 -1/4' (31,8 mm) . CLOSURE SERIES 1 -1/4° (31,8 mm) • • CLOSURE TY-FRB • , 314' (19,1 mm) . Ty-FRB 1' (25,4 mm) FIGURE 7 : • • • FIGURE 8 SERIES TY -FRB RECESSED PENDENT . - SERIES TY -FRB RECESSED - PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON • .. STYLE 20 RECESSED ESCUTCHEON . 4.2 K- FACTOR, 1/2 INCH NPT 4.2 K- FACTOR, 1/2 INCH NPT used to cover a clearance hole, may and after installation. Sprinklers dam - Care and delay the time to sprinkler operation in aged by dropping, striking, wrench a fire situation. twist/slippage, or the like, must be re- Maintenance S that are found to be leakin placed. Also, replace any sprinkler that Sprinklers g has a cracked bulb or that has lost q The Series TY -FRB Sprinklers must be or exhibiting visible signs of corrosion liquid from its bulb. (Ref. Installation maintained and serviced in accord- must be replaced. Section). ance with the following instructions: Automatic sprinklers must never be Frequent visual inspections are rec- • painted, plated, coated or otherwise ommended v to be initially performed for NOTES altered after leaving the factory. Modi- corrosion resistant coated sprinklers, Before closing a fire protection system fied sprinklers must be replaced. after the installation has been corn- main control valve for maintenance Sprinklers that have been exposed to plated, to verify the integrity of the cor- work on the fire protection system that corrosive products of combustion, but rosion resistant coating. Thereafter, - -it controls,- permission -to shut-down -the- —have• not- operated,•should.be- replaced_ annual- inspections- per -N FP-A_25— _ - - _ _. affected fire protection system must be if they cannot be completely cleaned should suffice; however, instead of in- obtained from the proper authorities by wiping the sprinkler with a cloth or specting from the floor level, a random and all personnel who may be affected by brushing it with a soft bristle brush. sampling of close -up visual inspec- by this action must be notified. Care must be exercised to avoid dam- .tions should be made, so as to better Absence of an• escutcheon.. which is age to the sprinklers - before, during, determine the exact- sprinkler condi- TFP171 Page 7 of 8 2 -7/8' DIA. 2 -718' DIA. (73,0 mm) 3/4' (19,1 mm) 1/2±1/8' (73,0 mm) 5/8±1/4' 1/2' (12,7 mm) (15,9±6,4 mm) 2 -1/4' DIA. 1/4' (6,4 mm) (12,7±3,2 mm) 2 -1/4' DIA. 1/4' (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8' ■� 1/8' ■ _ ( 3,2 mm) ■.i (3,2 mm) i 1 • ri AFA M ■ 1. f , MOUNTING II' MOUNTING SURFACE _ I - SURFACE ='= ' v CLOSURE SERIES • 1 -1/4' (31,8 mm) SERIES 1 -1/4' (31,8 mm) TY -FRB CLOSURE 3/4' (19,1 mm) TY -FRB 1' (25,4 mm) FIGURE 9 FIGURE 10 SERIES TY -FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT 5.6 K- FACTOR, 1/2 INCH NPT .2 -7/8' DIA: - ' 2 -7/8' DIA. • • 5/8 ±1/4' . (73,0 mm) 3/4' (19,1 mm) • ' 1/2±1/8' . (73,0 mm) 1/2' (12,7 mm) (15,9±6,4 mm) 2 DIA. 1/4' (6,4 mm) 12,7±3,2 mm) 2 -1/4' DIA. 1/4' (6,4 mm) (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING FACE OF PLATE SPRINKLER PLATE SPRINKLER FITTING FITTING 1/8' 1/8' II i ' Eliii (3,2 mm) " (3,2 mm) raWr Al - I I \ . ' + . f i MOUNTING II I MOUNTING 1 SURFACE SURFACE I f • _____ ' CLOSURE SERIES • 1 -5/16' (33,3 mm), CLOSURE SERIES 1 -5/16' (33,3 mm) TY -FRB • 13/16' (20,6 mm) TY -FRB 1 -1/16' (27,0 mm) • FIGURE.11 FIGURE 12 • SERIES TY -FRB RECESSED PENDENT • • • SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT 8.0 K- FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may 4c...-: RECESS be affected by the corrosive conditions present. WRENCH RECESS1*P The owner is responsible for the in- (END "A° USED FOR j spection, testing, and maintenance of ^ 1/2° NPT MODELS) their fire protection system and de- .►� vices in compliance with this docu- (,....i.,ILIIIIT ment, as well as with the applicable era standards of the National Fire Protec- WRENCH RECESS PUSH WRENCH tion Association (e.g., NFPA 25), in (END "B° USED FOR IN TO ENSURE addition to the standards of any other 3/4° NPT MODELS) ENGAGEMENT authorities having jurisdiction. The in- WITH SPRINKLER stalling contractor or sprinkler manu- FIGURE 13 WRENCHING AREA _ facturer should be contacted relative to - W- -TYPE 6 SPRINKLER _, _ _._ __ _ _ _ _ ____ _____ _ _ _ any questions. WRENCH It is recommended that automatic FIGURE 14 • sprinkler systems be ins local requirements and /or national W 7 RECESSED tested, and maintained by a qualified codes. SPRINKLER WRENCH Inspection Service in accordance with Page 8 of 8 TFP171 P/N 57 -XXX -X- XXX • TEMPERATURE MODEL/SIN RATING SPRINKLER 330 2.8K UPRIGHT (1 /2 "NPT) TY1131 135 135 °F /57 °C 331 2.8K PENDENT (1 /2 °NPT) TY1231 1 NATURAL BRASS 155 155 °F /68 °C • 340 4.2K UPRIGHT (1 /2 °NPT) TY2131 4 WHITE POLYESTER 175 175Ff79°C 341 4.2K PENDENT (1 /2 °NPT) TY2231 3 WHITE (RAL9010)' 200 200 °F /93 °C 370 5.6K UPRIGHT (1 /2 "NPT) TY3131 9 CHROME PLATED 286 286 °F /141 °C 371 5.6K PENDENT (1 /2 "NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT (3 /4 "NPT) TY4131 ' 391 8.0K PENDENT (3 /4 "NPT) �TY4231 . ' Eastern Hemisphere sales only. • • • TABLE C ' PART NUMBER SELECTION . • , SERIES TY -FRB PENDENT AND UPRIGHT SPRINKLERS ORY, FOR INCIDENTAL, INDIRECT, Recessed Escutcheon: Limited SPECIAL OR CONSEQUENTIAL Specify: Style (specify) Recessed Es- DAMAGES, INCLUDING BUT NOT cutcheon with (specify finish), P/N Warranty LIMITED TO LABOR CHARGES, RE- (specify). GARDLESS OF WHETHER TYCO Products manufactured by Tyco Fire FIRE PRODUCTS WAS INFORMED 1/2' (15 mm) . Products are warranted solely to the ABOUT THE POSSIBILITY OF SUCH Style 10 original Buyer for ten (10) years DAMAGES, AND IN NO EVENT Chrome Plated P/N 56- 701 -9 -010 against defects in material and work- SHALL TYCO FIRE PRODUCTS' LI- White h to RAL9010' P/N 56-701-3-010 • manship when paid for and properly ABILITY EXCEED AN AMOUNT Brass Plated P/N 56-701-2-010 ' installed and maintained under normal EQUAL TO THE SALES PRICE. . use and service. This warranty will ex- THE FOREGOING WARRANTY IS 1/2' (15 mm) pire ten (10) years from date of ship- Style 20 • ment by Tyco Fire Products. No war - FADE IN LIEU OF ANY AND ALI, Chrome Plated P/N 56- 705 -9 -010 ranty is given for products or OTHER WARRANTIES EXPRESS OR White Coated P/N 56- 705 -4 -010 ' IMPLIED. INCLUDING components manufactured by comps OF MERCHANTABILITY AND F T- White P sled 10• P/N 56- 705 -2 -010 • nies not affiliated by ownership with NESS FOR A PARTICULAR PUR- Tyco Fire Products or for r products and POS 3/4° (20 mm) components which have been subject . Style 30 to misuse, improper installation, corro- V Chrome Plated P/N 56- 705 -9 -011 sion, or which have not been installed, White Coated P/N 56- 705 -4 -011 maintained, modified or repaired in ac- O rdering White Plated 0° P/N 56- 705 -3-011 cordance with applicable Standards of Brass Plated P/N 56-705-2-011 the National Fire Protection Associa- Procedure 3/4° (20 mm) tion, and /or the standards of any other Style 40 Authorities Having Jurisdiction. Mate- Ocieteia4gun total distributor for avail- Chrome Plated P/N 56- 700 -9 -010 rials found by Tyco Fire Products to be ability indicate the White Coated P/N 56- 700 -4 -010 defective shall be either repaired or tulproduct White RAL9010' P/N 56- 700 -3 -010 replaced, at Tyco Fire Products' sole name. Refer to Brass Plated P/N 56- 700 -2 -010 fe p y the Price List for option. Tyco Fire Products neither as- complete listing • Eastern Hemisphere sales only. sumes, nor authorizes any person to of Part Numbers. assume for it, any other obligation in Sprinkler Wrench: connection with the sale of products or Sprinkler Assemblies with NPT Specify: W -Type 6 Sprinkler Wrench, parts of products. Tyco Fire Products Thread Connections: P/N 56- 000 -6 -387. . - shall not be responsible for sprinkler Specify: (Specify Model /SIN), Quick system design errors or inaccurate or Response, (specify K- factor), (specify Specify: W -Type 7 Sprinkler Wrench, ___incomplete information supplied by temperature rating), Series TY-FRB P/N 56- 850 -4 -001. Buyer or Buyer's representatives. (specify Pendent or Upright) Sprinkler IN NO EVENT SHALL TYCO FIRE with (specify type of finish or coating), PRODUCTS BE LIABLE, IN CON- P/N (specify from Table C). • TRACT, TORT, STRICT LIABILITY OR ' UNDER ANY OTHER LEGAL THE- . TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 • • tqcci I Fire & Building - Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series RFII — 5.6 K- factor • "Royal Flush II" Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Cap. The Protective Cap is temporarily : . removed for installation, and then it can be replaced to help protect the Description sprinkler while the ceiling is being in- . ' stalled or finished. The tip of the Pro - The Series RFII Quick Response tective Cap can also be used to mark rte^^ (3 mm bulb) & Standard Response (5 . the center of the ceiling hole into plas- ter ' ... mm bulb), 5.6 K- Factor, "Royal Flush ter board, ceiling tiles, etc. by gently f(. . :- .7:- — `'�; 4 II" Concealed 'Pendent Sprinklers are pushing the ceiling product against the . decorative sprinklers featuring a flat Protective Cap. When the ceiling in- cover plate designed to conceal the • stallation is complete the Protective "\ sprinkler. It is the best choice for archi- Cap is removed and the Cover Plate \,.` . / tecturally sensitive areas such as hotel Assembly installed. lobbies, office buildings, churches, As an option, the Series RFII Standard and restaurants. Response (5 mm bulb) "Royal Flush II" Each unit includes a Cover Plate As- Concealed Pendent Sprinklers may be sembly that conceals the sprinkler op- fitted with a silicone Air and Dust Seal UL, C -UL, and NYC. Maximum 175 erating components above the ceiling. (Ref. Fig. 5). The Air and Dust Seal is psi (12,1 bar) by FM. The separable two -piece design of the intended for sensitive areas where it is • Cover Plate and Support Cup Assem- desirable to stop air and dust travel Technical blies allows installation of the sprin- through the cover plate from the area • • klers and pressure testing of the fire above the ceiling. Data protection system prior to installation WARNINGS of a suspended ceiling or application The Series RFII Concealed Pendent Approvals for Series RFII of the finish coating to a fixed ceiling. S rinklers described herein must be UL and C -UL Listed. FM Approved. They also permit removal of, sus i n s talled and maintained in compli- NYC under MEA 353 -01 -E. LPCB (Ref. • pended ceiling panels for access to ance with this document, ' as well as No. 094a/09 for TY3551 & 094a/10 for • building service equipment without with the applicable standards of the TY3531) Approved. • having to first shut down the fire pro l Fire National Protection Association, tection system and remove sprinklers. The approvals apply only to the sery Also, the separable two-piece sprinklers. design in addition to the standards of any ice conditions indicated in the Design • P P g other authorities having jurisdiction. Criteria section and maximum pres- of the the Sprinkler provides for 1/2 Failure to do so may impair the per- sure ratings indicated in the inch (12,7 mm) of vertical adjustment, formance of these devices. Model /Sprinkler Identification Num- to reduce the accuracy to which the The owner is responsible for maintain- bers section. length of fixed pipe drops to the sprin- klers must be cut., m g their fire protection system and de- Approvals for Air & Dust Seal The Series RFII Sprinklers are vices in proper operating condition. (part. #10908100) P The installing contractor or sprinkler UL and C -UL Listed for use with the shipped with a Disposable Protective manufacturer should be contacted RFII (TY3551 & TY3504) Standard Re- • with any questions. sponse Concealed Sprinkler. IMPORTANT Model/Sprinkler Temperature Ratings M odel /S Always refer to Technical Data p 155F/68C Sprinkler - 135F/57C Plate Sheet TFP700 for the `INSTALLER 200F /93C Sprinkler - 165F/74C Plate WARNING" that provides cautions Identification Discharge Coefficient • with respect to handling and instal- K = 5.6 GPM /psi / (80,6 LPM /bar /2 ) lation of sprinkler systems and com- Numbers Adjustment ponents. Improper handling and in- 1/2 inch 12,7 mm) -- stallation can permanently damage — TY3551�(5 mm - bulb) - & TY3531 - (3 - mm � — - -- - -- — --- a sprinkler system or its compo- bulb): maximum 175 psi (12,1 bar) by Finishes Cover Plate: Chrome Plated, Brass nents and cause the sprinkler to fail UL, C -UL, FM, LPCB and NYC. to operate in a fire situation or cause TY3504 (5 mm bulb) & TY3505 (3 mm Plated, or White Painted (Custom paint matches and colors other than white it to operate prematurely. bulb): maximum 250 psi (17,3 bar) by are available on request.) , Page 1 of 4 JULY, 2004 TFP181 • Page 2 of 4 TFP181 ' - Physical Characteristics 1/2' NPT 9 N f /. SEALING Frame Bronze , ASSEMBLY Support Cup . Chrome Plated Steel Guide Pins Stainless Steel I j% � + � Deflector Bronze FRAM , 4 � Compression Screw Brass -' CAP I I ! p Bulb Glass Cap Bronze or Copper SUPPORT Sealing Assembly CUP WITH BULB Beryllium Nickel w/Teflon' ROLL FORMED l Cover Plate Brass THREADS Retainer Brass \ MPRESSION Eject Spring .... Stainless Steel �,. C O SCREW • GUIDE Mi� Patents PINS (2) =% U.S.A. 4,014,388 • I „_ I DEFLECTOR Operation ti ' (DROPPED • DEFL I 1 J L� POSITION) c z When exposed to heat from a fire, the 1 SPRINKLER/SUPPORT CUP Cover Plate, which is normally sol- I ASSEMBLY dered to the Retainer at three points, • • falls away to expose the Sprinkler As- THREAD INT I RETAINER sembly. At this point the Deflector sup- SUPPORT CUP , . ( WITH THREAD y p p UNTIL MOUNTING O O ) DIMPLES • ported by the Guide Pins drops down SURFACE IS • _ to its operational position. • FLUSH WITH EJECTION • The glass Bulb contains a fluid that • CEILING SPRING expands when exposed to heat. When . the rated temperature is reached, the i fluid expands sufficiently to shatter the - �, glass Bulb, activating the sprinkler and allowing water to flow. SOWER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY Design FIGURE 1 • . Criteria SERIES RFII CONCEALED SPRINKLER ASSEMBLY - The RFII (TY3551 & TY3504), 5 mm • Bulb Type, Concealed Pendent Sprin Step 1. The sprinkler must only be klers are UL and C -UL Listed as stand I nsta l lation installed in the pendent position and and response standard 'spray sprin- • with the centerline of the sprinkler per - klers for use in accordance with the The Series RFII must be installed in pendicular_to the mounting surface. current NFPA standard. They are FM accordance with the following instruc Step 2. Remove the Protective Cap. Approved as standard response - tions: - standard spray sprinklers for use in Step 3. With pipe, thread sealant ap- accordance with the current FM Loss NOTES plied to the pipe threads, hand tighten Prevention Data Sheets. Do not install any bulb type sprinkler if the sprinkler into the sprinkler fitting. The RFII (TY3531 & TY3505) 3 mm the bulb is cracked or there is a loss of Step 4. Wrench tighten the sprinkler Bulb T e, Concealed Pendent 3 rim liquid from the bulb. With the sprinkler using only the RFII Sprinkler Wrench yp p held horizontally, a small air bubble klers are UL and C -UL Listed as quick should be present. The diameter of the kler as (Ref. Figure be The RFII the Sprin- W response - standard spray sprinklers air bubble is approximately 1/16 inch re w to in n Figure ed re 3. . the Sprin for use in accordance with the current (1,6 mm) for the 155"F/68°C and 3/32 shown i NFPA standard. They are FM Ap- inch (2,4 mm) for the 200 °F /93 °C tern Step 5. Replace the Protective Cap proved as standard response - stand- perature ratings. (Ref. Figure 4) by pushing it upwards and spray sprinklers for use in accord- A leak tight 1/2 inch NPT sprinkler joint until it bottoms out against the Support ance with the current FM Loss should be obtained with a torque of 7 Cup. The Protective Cap helps prevent Prevention Data Sheets. q damage to the Deflector and Arms dur- The Series RFII Concealed Pendent to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi ing ceiling installation and /or during mum of 21 ftlbs Sprinklers are only listed and a ft.lbs. (28 Nm) of torque application of the finish coating of the p y p is to be used to install sprinklers. proved with the Series RFII Concealed Higher levels of torque may distort the ceiling. center r o of also le be used to hole y the . Cover Plates having a metallic or white sprinkler inlet with consequent leak y pushing the cg the ceiling m ng m ateria l u material up gently pus painted finish. riap age or impairment of the sprinkler. against the center point of the Protec- __The Series RFII must not be used in Do- not - attempt -to- compensate for in tive - -- -- - - -- - a'pplications where the air pressure sufficient adjustment in the Sprinkler above the ceiling is greater than that Assembly by under- or over - tightening NOTE below. Down drafts through the Sup the Sprinkler /Support Cup Assembly. As long as the Protective Cap remains port Cup could delay sprinkler opera Readjust the position of the sprinkler in place, the system is considered to tion in a fire situation. fitting to suit. be "Out of Service ". • Registered Trademark of DuPont • TFP181 Page3of4 • FACE OF CLEARANCE HOLE CLEARANCE �. . (' SPRINKLER DIAMETER - HOLE \ FITTING DIMENSION C ) • SPRINKLER II SUPPORT CUP i 1,,,, ASSEMBLY \`t011 � ,� ,le 1/2° (12,7 mm) THREADED D ADJUSTMENT � FACE OF CEILING, f N FIGURE 4 MOUNTING RETAINING RING D ISPOSABLE PROTECTIVE CAP � ' SURFACE I1•I � � Ste 6. Aft er the ceiling has been corn - / / / pleted with the 2 -1/2 inch (63,5 mm) , ` A � . _� __ , ' diameter clearance hole and in prepa- ration for installing the Cover Plate As- � sembly, remove and discard the Pro �= r= T = � - r = ' tective Cap, and verify that the 3/16° to 11/16° . MANUFACTURER .. DEFLECTOR COVER PLATE • Deflector moves up and down freely. If , move e damaged and (4,8 to 17,5 mm) . PRESET GAP the S nnkler -has been . IN DROPPED RETAINER • the Deflector does •not and REFERENCE 3/32° (2,4 mm) POSITION ASSEMBLY down freely,. replace the entire Sprin- COVER PLATE COVER PLATE kler assembly..Do not attempt to mod- - PROFILE DEPTH DIAMETER - ify or repair a damaged sprinkler. DIMENSION B DIMENSION A ` . Step 7. —When installing an Air and . Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and A: 3 -1/4" (82,6 mm) C: 2 -3/8" to 2 -5/8° (60,3 to 66,7 mm) Dust Seal, verify the angle of the out - B: 3/16" (4,8 mm) D: 1 -3/4° to 2 -1/4" (44,5 to 57,2 mm) side edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the FIGURE 2 Air and Dust Seal and continue around SERIES RFII CONCEALED SPRINKLER the retainer until the entire Air and • I NSTALLATION DIMENSIONS Dust Seal is engaged. NOTE • The Air and Dust Seal is only to be installed on the periphery of the Re- o. ' tainer. --- 1 ► :IIL FRAME '. J1 =4L .- REF r . Step 8. Screw on the Cover Plate /Re ARM ' ;� tain Assembly until the Retainer i Figure 2 (or Air and Dust Seal - Figure i NI ' 5) contacts with the ceiling. Do not • j SUPPORT continue to screw on the Cover CuP ; i , Plate /Retainer Assembly such that it �' � ; 1_11 __ _ lifts a ceiling panel out of its normal I ^��� position. If the Cover Plate /Retainer I■ 4 Assembly cannot be engaged with the O Support Cup or the Cover Plate /Re- 7/8° (23 mm) tainer Assembly cannot be engaged SQUARE sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. ALIGN J ` . Care and ARROWS WITH FRAME ARMS - Maintenance • ACCEPTS \. .' The Series RFII must be maintained 0 1/2° SOCKET , -r and serviced in accordance with the - " - - -- - - - -- 'DRIVE — --- - - -- - following - instructions: NOTES FIGURE 3 Absence of the Cover Plate Assembly RFII SPRINKLER WRENCH may delay sprinkler operation in a fire situation. Page 4 of 4 TFP181 When properly installed, there is a SUPPORT SPRINKLER • FACE OF ORIENT nominal 3/32 inch (2,4 mm) air gap CUP CEILING SEAL • between the lip of the Cover Plate and , BEVEL AS • the ceiling, as shown in Figure 2. This — '� =�`— —� i SHOWN air gap is necessary for proper opera- PL A TE �1 j �� tion of the sprinkler. If the ceiling is to , RETAINER be repainted after the installation of ? ) ;► , ASSEMBLY � the Sprinkler, care must be exercised ) � — to ensure that the new paint does NOT ■, Nr ■ ' ; ? f seal off any of the air gap. Am; '; � � CLEAN Factory painted Cover Plates MUST ������'� ROOM NOT be repainted. They should be re- � r _ " — � LIP OF COVER SEAL placed, if necessary, by factory RETAINER PLATE painted units. FIGURE 5 Do not pull the Cover Plate relative to OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551 & TY3504) the Enclosure. Separation may result. . Before closing a fire protection system Inspection Service in accordance with DAMAGES, AND IN NO EVENT main control valve for maintenance local requirements and /or national SHALL TYCO FIRE PRODUCTS' LI- work on the fire protection system that codes. ABILITY. EXCEED AN AMOUNT it controls, permission . to shutdown the . EQUAL TO THE SALES PRICE. affected fire protection system must be THE FOREGOING WARRANTY IS obtained from the proper authorities Limited . MADE IN LIEU OF ANY AND ALL • and all personnel who may be affected . OTHER WARRANTIES EXPRESS OF( by this action must be notified. Warr IMPLIED. INCLUDING WARRANTIES Sprinklers that are found to be leaking Products manufactured by Tyco Fire OF MERCHANTABILITY AND 'FIT- or exhibiting visible signs of corrosion Y y NESS FOR A PARTICULAR PUR- must be replaced. Products are warranted solely to the POSE. Automatic sprinklers must never be original Buyer for ten (10) years Au n A ed, plated, coated must against defects in material 'and work- . altered a n after leaving the factory. r otherwise Modi- e manship when paid for and properly Ordering installed and maintained under normal fied d sprinklers must be replaced. d. use and service. This warranty will ex- Procedure Sprinklers corrosive fter lea that have ve been exposed of combustion, but pire ten (10) years from date of ship - have not operated, should be replaced ment by Tyco Fire Products. No .war- When placing an order, indicate the full ranty is given for products or product name. Contact your local dis- if they cannot be completely cleaned P Y components manufactured by comps tributor for availability. by wiping the sprinkler with a cloth or :nies not affiliated by ownership with . ty by brushing it with a soft bristle brush. Tyco Fire Products or for products and Sprinkler Assembly: Care must be exercised to avoid dam- components which have been subject Specify: (SIN), (specify temperature age to the sprinklers - before, during, , to misuse, improper. installation, corro- rating) Series RFII Concealed Pen- • and after installation. Sprinklers dam- sion, or which have not been installed, dent Sprinkler, P/N (specify). aged by dropping, striking, wrench maintained, modified or repaired in ac applicable Standards of 1790- -1 2790 - twist/slippage, or the like, must be re- ' cordance with a 1-2 placed. Also, replace any sprinkler that PP TY3551 • 51-790-1-155 51-790-1-200 P P Y P the National Fire Protection Associa- TY35oa 51- 796-1 -155 51- 796-1 -200 has a cracked bulb or that has lost tion, and /or the standards of any other TY3531 51- 792 -1 -155 51- 792 -1 -200 liquid from its bulb. (Ref. Installation Authorities Having Jurisdiction. Mate - TY3505 51- 797 -1 -155 51- 797 -1 -200 Section). rials found by Tyco Fire Products to be If a sprinkler must be removed, do not defective shall be either repaired or Separately Ordered Cover Plate: reinstall it or a replacement without replaced, at Tyco Fire Products' sole Specify: (specify temperature rating) reinstalling the Cover Plate Assembly. option. Tyco Fire Products neither as- Series RFII Concealed Cover Plate If a Cover Plate Assembly becomes sumes, nor authorizes any person to with (specify finish), P/N (specify). dislodged during service, replace it im- assume for it, any other obligation in mediately. connection with the sale of products or 135F/57C(a) 16 - 792 parts of products. Tyco Fire Products Brass 56- 792 -1 -135 56- 792 -1 -165 P P Y Bright Brass 56- 792 -2 -135 56- 792 -2 -165 The owner is responsible for the in- shall not be responsible for sprinkler Chrome 56- 792 -9 -135 56 -792 -9 -165 spection, testing, and maintenance of system design errors or inaccurate or Brushed Chrome 56- 792 -- - protection system and de- incomplete information supplied by White 56- 792 -3-135 8 -135 56 792 792 -3-165 6 -165 their fire P Y P PP y White (RAL9010)' 56- 792 -3 -135 56- 792 -3 -165 vices in compliance with this docu- Buyer or Buyer's representatives. Bright White 56- 792 -4 -135 56- 792 -4 -165 ment, as well as with the applicable IN NO EVENT SHALL TYCO FIRE Off W hite 56- 792 -5 135 56- 792 -5 -165 standards of the National Fire Protec- PRODUCTS BE LIABLE, IN CON Black Custom ss 56 - 7s2 -s 135 56 - 7s2 -s -1 tion Association (e.g., NFPA 25), in TRACT, TORT, STRICT LIABILITY OR - 7s2 -x-135 ss- 7s2 -x -ls addition to the standards of any other UNDER ANY OTHER LEGAL THE (a) For use with 155F/68C sprinklers. (b) For use with 200F/93C sprinklers. authorities having jurisdiction. The in- ORY, FOR INCIDENTAL, INDIRECT, • Eastern Hemisphere sales only. stalling contractor or sprinkler manu- SPECIAL OR CONSEQUENTIAL • - --- -- facturer should to -- DAMAGES - INCLUDING - BUT-NOT— Sprinkler Wrench: -- - - -- - -- - - ---- -- -- any questions. LIMITED TO LABOR CHARGES, RE- Specify: RFII Sprinkler Wrench, It is recommended that automatic GARDLESS OF WHETHER TYCO P/N 56-000-1-075. sprinkler systems be inspected, FIRE PRODUCTS WAS INFORMED Air and Dust Seal: tested, and maintained by a qualified ABOUT THE POSSIBILITY OF SUCH Specify: Air and Dust Seal, P/N 56- 908 -1 -001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446