Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications
4 WiS rg71 e Fp52Gll- OCOS(n JUL 05 zap I�I�Ow m,. P� . ,,„i L d2,4 eZZC; �nNi+ MATERIAL SUBMITTAL ' COVER SHEET: DOW AGRO SCIENCES 16160 SWABOONES FERRY ROAD TIGARD, OREGON SERVER AND LAN ROOMS FENWALNET 6000 DETECTION, ONTROLS & FM -200 CLEAN AGENT SYSTEM DESIGNED AND INSTALLED BY SPECIAL HAZARD FIRE PROTECTION CONTRACTOR: SUPfRESSION SYSTEMS, INC. SPECIAL HAZARD FIRE PROTECTION 4417 PACIFIC HIGHWAY EAST TACOMA, WA 98424 - 2611 Ti, (253) 926-3300 FAX (253) 926 -3306 • FENWALNET 6000 Effective: October 2006 Fire -Alarm /Suppression- System Control Unit 74-600 FEll WAL FEATURES • Distributed Intelligence to Sensor Level • Peer -to -Peer Networking of up to 32 Control Units • Fully- Digitized Communications Protocol • Remote Releasing Capability • Up to 255 Points without Device -Type Restrictions • USB Communications Port • Triple -R Protection Against Inadvertent • Internet Accessible Extinguishing- System Activation • Simple Programming • Inherently Power Limited • UL, CSFM, MEA Listed /FM Approved DESCRIPTION The FENWALNET 6000 Fire -Alarm / - Suppression- System Control Unit is a compact control unit that provides one sig- naling line circuit, four notification - appliance circuits, two releasing circuits, and four on -board relays. Two of the four notification - appliance circuits are user - configurable to actu- ate one solenoid valve for control of a special- extinguishing system or a pre- action / deluge sprinkler system. A 5.4 -A, – - o-- ooc filtered and regulated power supply provides charging capa- I t o- Ec - o– ooG bilities for batteries up to 70 AH. The FENWALNET 6000 Control Unit annunciates alarm, - r" :;,. trouble, and supervisory events via an 80- character, backlit • LCD display with integral status LEDs. Event acknowledg- - ment, alarm silence, and system reset are accomplished with dedicated control keys. Basic user and maintenance operations such as viewing history or isolation commands to initiating points and system outputs are performed via the control keys and associated digit keys. A security password prevents unauthorized access to the system. Signaling Line Circuit FENWALNET 6000 The signaling line circuit communicates with up to 255 SmartOne TM automatic initiating devices, monitor modules, and control modules via a highly - efficient, fully- digitized pro- tocol. The SmartOne communications protocol imposes no occurred. SmartOne smoke detectors can also be config- limitations on the mix of automatic initiating devices and ured for non - latching operation that requires them to mea- monitor /control modules on the signaling line circuit. Each sure smoke signatures in excess of their alarm thresholds SmartOne initiating device has a microprocessor, memory, for the entire pre- discharge time period in order to discharge and decision - making algorithms to interrupt normal control - unit communications and initiate an alarm signal the extinguishing system. This prevents a transitory event that mimics a smoke signature such as the leakage of air - This distributed intelligence to the sensor level ensures rapid conditioning fluid from accidentally discharging the extin- response to all types of initiating signals, and is far superior guishing system. to the various sequential, poll-and-respond communication SmartOne heat detectors have pre -alarm and alarm thresh - schemes employed by others that rely on the control unit to olds that are programmable in 1F° intervals. make all alarm decisions. SmartOne smoke detectors man- _ age their individual drift- compensation routines, and have pre- The signaling line circuit can be wired for Class -A, Style -6 or alarm and alarm thresholds that are configurable in 0.1 Class -B, Style -4 operation. Optional isolator modules can percent - per -foot increments throughout the entire range of be used for a Class -A, Style -7 circuit. • Listed sensitivities. The control unit can dynamically adjust the smoke - detector alarm thresholds as the result of one or more alarm- initiating events to confirm that a fire requiring the rapid action of an associated extinguishing system has Releasing Circuits The MT and NS Series notification appliances provide the The FENWALNET 6000 Control Unit has two releasing cir- option to use silenceable horns and non - silenceable strobes cuits that can be configured to actuate releasing devices via on the same NAC. any of the following ways: Two of the NACs are also user - configurable to activate one • Single control head or solenoid valve solenoid for special- extinguishing- system actuation or pre - action / deluge sprinkler- system actuation like the regular • Two series - supervised, parallel- actuated control heads releasing circuits. These NACs are also protected against or solenoid valves. inadvertent activation via the main microprocessor by the • One Metron actuator FENWALNET 6000 "Triple -R" safeguard system when they These releasing circuits can be used to actuate various are configured for releasing applications. Fenwal control heads for waterless- extinguishing- system On -Board Relays and Auxiliary Power storage containers, or solenoid valves for sprinkler control The FENWALNET 6000 has four Form -C relays. Three of that fall within the Factory Mutual System Groups A, B, D, the four relays are user - programmable for any system con - E, and G. A releasing circuit can actuate an unmatched pair dition and the fourth relay is dedicated to trouble conditions. of control heads or solenoid valves because it activates these Each relay is rated for 1 Amp @ 28 VDC. releasing devices in parallel, not in series. This means that a Two auxiliary-power outputs are provided, each with a 1 -A releasing circuit can activate the control valves for a water- output. These auxiliary-power outputs are user configurable less suppression system and a back -up pre- action - sprinkler for resettable or continuous power. system simultaneously which makes efficient use of the Integration with Specialty Detection Systems control unit's circuitry and increases system reliability by enabling a single action to operate both extinguishing sys- The FENWALNET 6000 is designed to integrate seamlessly tems. with AnaLASER II High Sensitivity Smoke Detectors (HSSD) via one or more AnaLASER II Interface Modules (AIM). It The releasing circuits are protected against inadvertent acti- also integrates with Fenwal's AlarmLine Cable via AlarmLine vation via the main microprocessor by the FENWALNET 6000 Addressable Modules and with Linear Heat - Sensing Cable exclusive "Triple -R" (for triple redundancy) safeguard system. (LHS) via regular monitor modules. The "Triple -R" system requires that the main microprocessor issue two release commands, of opposite polarity and via The AIM permits an HSSD to be connected to the signaling separate signaling channels, and that these commands be line circuit and report pre - alarms and alarms in an address- combined with a signal from the control unit's watchdog timer able manner analogous to a SmartOne smoke detector. confirming proper microprocessor operation, in order to acti- TheAAM permits an AlarmLine cable to be connected to the vete a release circuit. This triply- redundant release- command signaling line circuit and report pre - alarms and alarms in an requirement ensures that an electrical transient or disturbance addressable manner analogous to a SmartOne heat detec- that temporarily interferes with the operation of the main mi- tor. The LHS can report as a point - specific alarm via an Al croprocessor will not inadvertently activate an extinguishing Monitor Module. system. Programming Notification - Appliance Circuits The FENWALNET 6000 configuration tool is used to pro - The FENWALNET 6000 Control Unit has four notification- gram the control unit for each individual, site - specific appli- appliance circuits (NACs). Each circuit can provide up to 1.5 cation. Programming is for control -by -event scenarios, and Amps @ 24 VDC for horns, strobes, chimes, or other notifi- consists of entering a series of conditional control statements cation appliances. Power for the notification appliances is that logically join initiating points to control- unit -based out - fully filtered and regulated. Each NAC is programmable, and puts and remote control modules. Each SmartOne field de- supports continuous and master -coded outputs for audible vice can be assigned a location message of up to 40 devices. The NACs' coded patterns are dynamically adjust- characters via the FENWALNET 6000 configuration tool. A able and can be programmed to sound different codes to USB Device Port is available to connect to a laptop corn- notify the occupants of progressively- more - serious conditions. puter for application upload. Both circuits are supervised, power limited, and are compat- A front - panel- activated AutoLearn routine can be executed ible with conventional, UL- Listed, 24 -VDC notification appli that will create a general - alarm, one - input- activates -all out - ances. They can also be used with the following Fenwal puts application to speed the system- configuration pro - synchronizable horns and strobes without the requirement cess. The more - sophisticated Auto -Setup routine allows of an external synchronization module: the FENWALNET 6000 System to be automatically con- MT Series Multi -Tone Horns and Horn /Strobes figured for the typical control scenario utilized by water - NS Series Horn /Strobes less fire - suppression systems. • NH Series Horns RS Series Strobes • Event initiation • OPTIONAL MODULES • Protected - premises local and /or Remote LCD Annunciator remote event annunciation • The FENWALNET 6000 Control Unit supports up to 15 re- 'Occupant notification via audible and visible mote LCD annunciators called RDCMs. This remote annun- ciator uses the same 80- character, backlit LCD display found • Process /equipment control to activate safety on the main control unit. The RDCM permits remote event procedures acknowledgment, alarm silencing, and system reset, and is • Fire extinguishing system release secured with a key lock. User- and maintenance -level func- • Off - premises transmissions to central station or tions are also possible from the remote annunciator. fire department via third -party digital communicator Refer to Data Sheet 74 -235. and programmable relays. Graphic- Annunciator Driver The network provides several convenient interconnect pro - The Model ATM -L Annunciator Driver Module provides the gramming schemes wherein control panels can be config- FENWALNET 6000 Control Unit with up to 32 programmable, ured individually or within created groups of control panels. supervised LED outputs for graphical or tabular annuncia- When utilizing the grouping configuration, the interconnec- tors, along with 6 system -level LED outputs and 5 system- tion shall automatically provide shared alarm and trouble re- level inputs circuits for functional switches. sponses. The programmable shared responses are: The system -level LEDs correspond to the following general acknowledge, silence, reset, event logging and logic state - conditions: Module Power, Pre - Alarm, Alarm, Alarm Silence, ments. Operator events can be activated into the intercon- Supervisory, and Trouble. nection via the control panels or any annunciator. A location The input circuits for functional switches provide for the fol- address and programmable description shall identify the lowing operator intervention: System Reset, Event Acknowl- Panel initiating the event. edgment, Alarm Silence, Fire Drill, and Lamp Test. Refer to Data Sheet 74 -602. The FENWALNET 6000 supports up to 16 graphic - annun- Remote Releasing Module ciator - driver modules. The Remote Releasing Module (RRM) is a Smart °nen" field Refer to Data Sheet 74 -236. device that provides the ability to remotely activate extin- Intelligent Communications Module guishing- system control devices. Connection is via the FENWALNET 6000 Control Unit's Signalling Line Circuit The Intelligent Communications Module (ICM) can be used (SLC). The control unit's SLC supports a maximum of 64 • to access the FENWALNET 6000 System via the Internet to RRMs. Up to 16 RRMs can be configured for simultaneous view system- status and current events and to download the group activation, with a maximum of 4 groups. history log. The ICM can be programmed to transmit up to The RRM provides internal supervision of communication with five e-mails upon the occurrence of any unsolicited event in the FENWALNET 6000 Control Unit, connections to exter- the system. The e -mail message embeds a link with the IP nal power supply and memory status. address of the control unit that sent the message for instant access to the remote system. Release circuits are power - limited and supervised for short The ICM can be accessed using any standard Web- brows- circuit by using an In -line Releasing- Circuit Device ing program and requires no special proprietary software. (P /N 06- 220023 -001). In the event of a ground fault, open, short or a relay contact failure, the device will transmit a The ICM also allows the FENWALNET 6000 Control Unit to trouble status to the FENWALNET 6000 Control Unit. report as a slave device via the Modbus TCP /IP Protocol to a Refer to Data Sheet 74.238K. master monitoring system for automated process control. Refer to Data Sheet 74 -603. Network Interface Card The FENWALNETTM 6000 Network Interface Card (P /N 74- 200036 -500) provides true peer - to-peer functionality when installed in the FENWALNET 6000 Control Unit. Added functionality is provided when the Fenwal® Remote Display Control Module annunciator(s) (P /N 74- 300000 -502) are connected to the individual control pan- els and, hence, into the interconnection scheme. • The network is capable of performing the following fire -alarm and /or suppression system operations on a network -wide basis: SPECIFICATIONS Primary AC Power: 120 Vac, 50/60 Hz, 3.2 A 2 Auxiliary-Power Programmable for Re- 220/240 Vac, 50/60 Hz, Outputs: sellable or Continuous 1.6 A Output 1 A @ 24 Vdc (each output) Power Output: 5.4 A @ 24 Vdc Filtered and Regulated 2 RS -232 Serial Ports: Bi- Directional Inherently Power Limited 9600 Baud, 8 Data Bits, 1 Stop Bit, No Parity Battery (Sealed, Lead- 70 AH Maximum Capacity 12 AH Fits within 1 RS-485 Maximum 31 Remote Acid Only): Communications Port: Addresses (RDCM and enclosure ATM -L) 1 Signaling Line Circuit: 255 Devices Maximum, Style 4, 6, or 7 (with 1 USB Device Port USB Serial Isolator Modules) Dimensions: Enclosure Only : 2 Notification-Appliance Class -A, Style -Z or Class- 14-1/4 in. W x 19 in. H x 5 Circuits: B, Style -Y 24 VDC, 1.5 A in. D (maximum per circuit) Enclosure with Door: Suitable for Synchronized 14-13/32 in. W x 19-5/32 Notification Appliances in. H x 5 in. D 2 Releasing Circuits: Configurable for Optional Modules: RDCM Remote Display - One or Two Control Module Heads and /or Solenoid ATM -L Annunciator Driver Valves Module One Metron Actuator ICM Internet- Accessible 24 Vdc, 2.4 A (maximum /Modbus-Conversion per circuit) Module Network Interface Card 2 Combination Circuits: Each Configurable as: Remote Releasing Module Class -A, Style -Z or Class - B, Style-1' NAC, 24 Vdc, ORDERING INFORMATION 1.5 A (Maximum per Part Number Description circuit) Suitable for 74 -600000 -001 FENWALNET 6000 Control Unit Synchronized Notification Appliances (Blue) OR 74 -600000 -510 FENWALNET 6000 Control Unit Release Circuit with One (Red) Control Head or Solenoid 74- 600000 -007 Trim Ring (Blue) Valve 24 Vdc, 2.4 A 74 -600000 -517 Trim Ring (Red) (maximum per circuit) OPTIONAL MODULES Relays: 3 Programmable and 1 Trouble Relay. Part Number Description - 1.0 A @ 30 Vdc 06- 220080-002 Intelligent Connector Module (ICM) (resistive) 74- 300004 -032 GraphicAnnunciator Driver (ATM-L) - 0.5 A @ 30 Vdc 74- 300000 -502 Remote LCD Annunciator (RDCM) (inductive) 74- 200036 -500 Network Interface Card (NIC) - 0.5 A @ 120 Vdc 70- 600000-001 Remote Releasing Module (RRM)- (inductive) Standard Mounting 70-600000-002 Remote Releasing Module (RRM)- Fenwal and SmartOne are registered trademarks of Kidde- Fenwal, Inc In- Cabinet Mounting AnaLASER, AlarmLine and FailSoft are tademarks of Kidde- Fenwal, Inc FEAL This literature is provided for informational purposes only KIDDE-FENWAL. INC assumes no respon- sibility for the product's suitability for a particular application The product must be properly applied to work correctly Protection Systems If you need more information on this product, or if you have a particular problem or question, contact r i KIDDE- FENWAL, INC. KIDDE-FENWAL INC , Ashland, MA01721 Telephone (508) 881-2000 \-< 400 MAIN STREET, ASHLAND, MA 01721 TEL. (508)881 -2000 FAX (508) 881 -8920 74 -600 10/06 ©2006 Kidde- Fenwal, Inc. Printed in USA www.lenwalrire corn Effective: January 2008 Addressable Contact Input Device S marlOne ® F -74 -214 FEATURES • Monitors N/O Or N/C Unpowered Contacts • Full Digital Communications • Signaling -line- circuit Connections: ,�, _ V i SmartOne � °3 • Class A, Style 6 or 7 or ` �,( 9 : ti 11` ' I • Class B, Style 4 •rtTSli.T.ar a m m .iT T.t„ _ • Class B Style B Initiating Device Circuit ,di _ W q •tixE a B, Style g ,y r''. :j w 41l Tf4 ► 12,-, � _ • Remote -led Output 4.1.4,-.,›., 4- Q � • Alarm Test From Compatible Control Unit Keypad 1 '(. ..:r., „%sE o=,-CO • UI Listed / FM Approved , v ` w 1 DESCRIPTION The SmartOne Addressable Contact Input Device (Al) is an intelligent field device with its own microprocessor, 4K of memory and electronics necessary to interface N/ SUPERVISION O or N/C unpowered contacts to the compatible control The Al continuously monitors the integrity of the follow - unit system. All of the electronics are contained in a high- impact polymer case, creating a very small and ing: durable device for installation. • Continuity of supervised wiring • Two types of Al's are available: an Al /NC for interfacing Power /Communications circuit voltage . to normally - closed devices and an Al /NO for interfacing • Internal power supply to normally -open devices. The Al may be located up to • Memory data 2,500 feet from the monitored device with #18 AWG wir- • Faulty entering of data into Al memory • ing. An end -of -line- resistor is required for supervision of FAILSOFT OPERATION the wiring to the device. Should there be a failure in the communication link FIELD PROGRAMMING between the Al and the microprocessor that controls its System address, owner location message and reporting signaling line circuit, the Al is capable of reporting a Zone type are programmable via the compatible control unit Alarm for the signaling line circuit and initiating a general configuration software program. alarm signal. During a general alarm, all outputs pro - The System address is a 4 -digit number that uniquely grammed for failsoft operation will activate. identifies each device. The owner location message is a STATUS LED 40- character, alpha numeric message that describes the A remote status LED may be connected to the Al. A slow location of the device. The reporting type is assigned to flash rate of approximately nine seconds indicates a nor - the Al depending on the functionality of the device being mal condition, a two - second flash rate indicates alarm monitored. and no flash indicates a trouble condition. vg ,0 �� • WIRING DIAGRAM SPECIFICATIONS . Input Voltage: 16.5 - 27.5 VDC . Typical N O Mating . °°"'`°' Standby Current: 450 µA Max M Alarm Current: 450 µA Max ' Max. No. Of Devices per See Nolen 1, 2, and 4 Communication Circuit: 255 (Will support all See Note devices in-alarm simul- ... I') / 1.) (10K Resistor) . taneously) SL ^Lino `.' i � i ( _) SLo a Operating Temperature:. -31 - 151.F ( -35 -66.C) � f ' See Note 3 Typlc I N C. Super/Nosy 0- 95% RH :7 Remote Optio LED - -- I * LED Pulse Modes ((Optional) ,, ii ii Si u ®;iii . -� -� Normal: 9 second interval See o nto©oo© ,�®. • y Trouble: LED is off • �p� I j� Alarm: 2 second interval EO it e II q . i • o o u U U©U (10K Resi NOTES ORDERING INFORMATION 1. Maximum 25 Q resistance per conductor/ 50 Q per Part Number Description circuit. 70- 407008 -001 Addressable Contact Input 2. Max. #14 AWG (1.5 mm=) wire. Device N.O. Min. #18 AWG (0.75 mm2) wire. 70- 407008 -002 Addressable Contact Input 3. Refer to Control Panel Manual for wiring specifica- Device N.C. tion. 70- 411001 -005 Package of 10 End -of -Line 4. Maximum 10 VDC @ 1 mA. Resistors 5. All wiring is power limited and supervised. 6. This module will not support 2 -wire smoke detec- . tors. • ARCHITECTURAL /ENGINEERING 7. Rating of LED circuit: 26 VDC Max., 7mA Max. If SPECIFICATIONS not used leave terminals open circuit. For specifications request a copy of the Architectural/ 8. N/O and N/C initiating device circuits are NFPA Engineering Specification Disk: Available from Kidde- Class B /Style B. Fenwal Inc. Marketing Department. 9. Al N/C is intended for non -fire applications. . ALARM TEST . Any or all Als can be tested by command from the com- patible control unit. Results of the test may be printed out • • at the system printer. • INSTALLATION The Al can be mounted in a North American 2- 1 /2 -in. (64 mm) deep, 1 -gang box, or standard 4 -in. square box, 1- 1 /2 -in. (38 mm) deep with cover. , The terminal block will accept #14, 16 and 18 AWG wire (1.5 mm2, 1.0 mm2, 0.75 mm SmartOne is a registered trademark of Kidde - Fenwal, Inc. This literature is provided for informational purposes only. KIDDE - FENWAL, INC. assumes no responsibility for the product's suitability for a particular application. The prod- Siiia uct must be properly applied to work correctly. If you need more information on this product, or if you have a particular problem or ques- tion, contact KIDDE- FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881 -2000. KIDDE - FENWAL INC. F -74 -214 Rev AD © 2008 Kidde - Fenwal Inc. Printed in USA 400 MAIN STREET, ASHLAND, MA 01721 • TEL: (508) 881 -2000 FAX: (508) 881 -8920 armor Kvlrin- Fnnurnl rnm Effective: June 2007 Addressable Relay Output Device S marlOne m F -74 -215 FEATURES • Full - Digital Communications • Addressable Control Point • Unpowered, SPDT Relay Contacts • Control -by -Event And /or By Time Operation SmartOne "' z 11 i :11 m • Status Indicator CA! r73 I • Unique Internal Supervision " 1 : T,IDC„ p : DESCRIPTION '!•MF S! D , �� 1 : ,;,„ dYD • •+NI W,, i V ^ The SmartOnen Addressable Relay Output Device (AO) r � ° " "` "•�!•� °= "' is an addressable output module for control of auxiliary N t1 . equipment such as air handlers, door release and eleva- �I" t4 ) tor recall. The AO connects directly to a compatible control unit's signaling line circuit and contains a SPDT relay to control auxiliary equipment. All of the electronics are contained in a small high- impact polymer case. This creates a small and durable device for installation. These features STATUS LED also allow the AO to be easily installed in virtually any A status LED is mounted on the unit and indicates the application. relay set or reset status by a two or nine second flash . The AO is field programmable with a unique four -digit interval. A trouble condition inhibits the status LED corn- address and a 40- character owner location message. pletely. The AO relay may be set or reset on command from the INSTALLATION • control unit. The AO can be mounted in a North American 1- 1 /2 -in. In addition to combinational -logic programming that uti- (64 mm) deep 1 -gang box, or standard 4 -in. square box lizes system inputs (i.e., events) to activate this device, 1- 1 /2 -in. (38 mm) deep with a cover. The terminal block the unit may be programmed for real -time clock opera- will accept #14, 16 and 18 AWG wire (1.5 mm2, 1.0 mm tion. The real -time clock programming permits the AO to 0.75 mm2). Sizes #16 and #18 are preferred. be activated and deactivated by the time of day, calendar date and day of the week. ,A INTERNAL SUPERVISION The AO is continuously monitored for: V`` r1 • Internal power supply voltages C • Faulty entering of data into AO's memory \ • Relay state equals command state J� �. An internal set of relay contacts provides a feedback sig- nal that confirms the activation of the addressable relay lmD:eApplications _ ' output. If the relay fails to operate at the appropriate time, the device transmits a trouble report for display by the control unit. • • • WIRING DIAGRAM NOTES - • 1. Max. #14 AWG (1.5 mm2) wire. • SeoNoto1 • Min. #18 AWG (0.75 mm2) wire. COM � -- F - 2. Refer to control unit's installation, operation and • Connecaons 1 maintenance manual for wiring specifications. • See Note 2 See Note 2 (C) • (0) ORDERING INFORMATION P °' ^ne I � I I ° uie • Part Number Description . - .1111■1 70- 408004 -001 Addressable Relay Output 121® 131FiToTkTA1 Z e n e C 2 1 3111 . Jp • �o tl It; • 151 •iji ro ARCHITECTURAL /ENGINEERING 14 4 I� 11 SPECIFICATIONS For specifications, request a copy of the Architectural / Engineering Specification Disk: Available from Kidde- SPECIFICATIONS - Fenwal Marketing Department. Input Voltage: • . 16.5 - 27.5 VDC ' Standby Current: 400 pA, Typical - Alarm Current: 400 pA, Typical Contact Ratings: • - Resistive Contact Rating: 2 A @ 30 VDC . - Inductive Rating: 1.0A @ 30 VDC, 0.6 PF • (Motor Control) .6A @ 120 VAC, 0.35 PF -Pilot Duty: 0.6A @ 30 VDC, • - 0.35 PF . Max. No. Of Devices per - Signaling Line Circuit: 255 V • - (all'can be activated).. Operating Temperature: - 31 °F - 151 °F ( -35 °C - 66 °C) EMI Immunity: Meets UL 864 • • Dimensions: 2.3" x 1.8" x 0.8" nominal V Shipping Weight: 5.1 oz (145g) - LED Pulse Modes: _ Normal: 9 second interval Trouble: LED is off • Alarm: 2 second interval • • • • • • This literature is provided for informational purposes only. KIDDE - FENWAL, INC. Smar TM assumes no responsibility for the product's suitability for a particular application. The prod- uct must be property applied to work correctly. . If you need more information on this product, or if you have a particular problem or ques- tion, contact KIDDE - FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881 -2000. KIDDE - FENWAL INC. F -74 -215 Rev AB © 2007 Kidde - Fenwal Inc. Printed in USA 400 MAIN STREET, ASHLAND, MA 01721 TEL: (508) 881 -2000 FAX: (508) 881 -8920 ADDRESSABLE SIGNAL Effective: August 2000 MODULE S marlOne 74.23 4 . • FEATURES • Full- digital communications • Addressable notification - appliance circuit (NAC) • Class A, Style Z or Class B, Style Y wiring ED • Field- configurable for 24 -VDC notification appliances or 25/70.7 Vrms speakers • Status indicator • Supervises power for notification appliances `'' • UL Listed / FM Approved -ADDRESSABLE SIGNAL /S OUNDER MODULE DESCRIPTION The Smart One TM Addressable Signal Module (ASM) is a notifi- cation- appliance circuit that connects to the signaling line cir- cuit of a compatible control unit. The ASM is an intelligent field device that contains its own microprocessor, 4K of memory and the necessary electronics to provide either 24 VDC for conven- • Alarm contact position tional notification- appliances or 25/70.7V for speakers. • Communications with the control unit • Internal power supply PROGRAMMING • Connections to external power supply for notification - appliances ' Each ASM can be configured to support speakers or audible- • Memory status visual notification appliances, and Class B, Style Y or Class A, Module supervision prevents switching audible or audio power Style Z operation. The module can also be programmed to sup- into a shorted circuit. port water flow, walk test, and drill modes. As with any Smart One device, addressing can be implemented from the hand -held pro- STATUS LED grammer (P/N 74- 100013-001) or the control panel keypad/menu. The Module can also be alarm tested upon command from the A status LED is mounted on the unit and indicates the module's control unit. Module faults are individually reported to compat- status by a two- second (alarm) or nine - second (normal) flash ible control units by module address, fault type, and fault -loca- interval. A trouble condition stops the flashing. tion message. OPERATION INSTALLATION The unit can be mounted in a 4" x 4" electrical box. Terminal Once installed and configured, the ASM requires little or no connections support wiring from #18 AWG (1.0 mm to #12 maintenance. Operation can be changed on site using on- AWG (4.0 mm The size of the wires used will determine elec- board switches and jumpers. trical box depth. SUPERVISION The depth of the electrical box is determined per Article 370 of the National Electrical Code. ASM volume is 8.94 cubic - inches. The ASM provides a fully supervised notification- appliance For ease of wiring, especially with solid wire, an extension ring • circuit for connection to either 24 VDC audible /visual appli- must be used. ances or 25/70.7 Vrms speakers. The module provides con- • tinuous internal supervision of: I SPECIFICATIONS AUDIO CIRCUIT OUTPUT • OUTPUT CIRCUIT CHARACTERISTICS 25 or 70 V rms 20 W (max.), non -power limited, Output Current Rating: 2.0 A max. @ 30 VDC reverse polarity supervised POWER SUPPLY TROUBLE CIRCUIT END OF LINE 20 W @ 70.7 Vrms RESISTOR 20 W @ 25.0 V rms • 4.7Kohms, 0.5 W MAXIMUM LINE RESISTANCES ( #12AWG WIRE) OPERATING TEMPERATURE RANGE Load Resistance Length • -31° F to 151° F, ( -35° C to 66 °C) (amps) (ohms) (ft.) OPERATING HUMIDITY RANGE 0.2 20.0 12.0K • 0 to 95 %, non - condensing 0.5 8.0 5.0K ORDERING INFORMATION 1.0 4.0 2.5K ADDRESSABLE SIGNAL MODULE 1.5 2.7 1.6K • 70- 200200 -001 2.0 2.0 1.2K FRONT COVER PLATE (PROVIDED WITH MODULE) • 06- 235714 -001 INTERNAL INSULATOR (PROVIDED WITH MODULE) TECHNICAL INFORMATION • 06- 235714 -001 PHYSICAL DESCRIPTION • Single printed circuit board secured to a universal plate WIRING DIAGRAM with insulator SLC LINE SLC LINE MOUNTING IN OUT 00 FOR 24VDC • A 4 ", 2-1/8" deep ( for #18 AWG) or 4-11/16", 2-1/8" deep SET PI JUMPERDE g - D DOAND M AL, 721 (for #12 AWG) standard, square electrical box is used. AND SWITCHSI ASHLAND. O . 20 CAT 00 0 -0 A 01 INSTRUCTIONS PIN 08-215717-001 Wiring specifications are recommended as minimums 1 2 3 1 A B I A B I PC LINE TERMINALS- POWER LMTD ON ON OFF I PC LINE I ALL OTHERS • POWER LIMITED for ease of wiring. See National Electrical Code (370). FOR AUDIO MODE Soa10aslll SET Pt JUMPER DEVICE F ROM I AUXJAUOIO MODE 0 ADDRESS • __ CONSTRUCTION ` SETTINGS AND SWITCH st ADDRESSABLE SIGNAL MODULE LISTED COMPATIBLE 1 2 3 • High impact polymer housing with 16 gauge mounting O FF OFF ON 1 AU % IN 1_ IouTPUTCl1 24VDCOR25/70.7VAC 9 P P Y 9 9 9 9 1+1 * I i ��TTRO� I+ +1 l NOTIFICATION bracket VERIFY SWITCH AND / i APPLIANCES JUMPER SETTINGS AND TEST PER SHIPPING WEIGHT NFPA72 —___/, • 10.5oz (298g) SUPPLY O LISTED 47K.1T EOL !El RESISTOR CURRENT DRAW S or alarm EXAMPLE OF SHOWING H. • 500 uA in standby TRVBLE �° STYLE Z SHOWING THE OPEN FOR CONTACT -o� o. ONLY ALLOWABLE EOL OPERATING VOLTAGE RANGE NORMAL STATUS RESISTOR POSITION —.NV'. - • 16.5 to 27.5 VDC REGULATED SUPPLY OR LISTED 25/70 7 VAC AUDIO EOL 1 RESSI STOR • 24 VDC nominal AMPLIFIER LISTED FOR EOL FIRE PROTECTIVE NOTIFICATION - APPLIANCE CIRCUIT END OF LINE SIGNALING SYSTEMS OUTPUT C .-- 5- i RESISTOR j+ -I- +I <nc ow EOL • 47K ohms, 0.5 W a� a RESISTOR NOTIFICATION - APPLIANCE CIRCUIT OUTPUT r EXAMPLE OF CLASS B, STYLE Y SHOWING THE ONLY ALLOWABLE EOL • 24 VDC, 2A(max.), power limited, reverse polarity RESISTOR POSITION supervised Refer to Installation instructions (P /N 06- 235717 -001) for additional information :,x z - This literature is provided for informational purposes only KIDDE- FENWAL,INC. assumes no responsibility for the product's suitability for a particular application The product must be prop - TM - oily applied to work correctly � � If you need more information on this product, or if you have a particular problem or question, contact KIDDE- FENWAL INC , Ashland, MA 01721. Telephone' (508) 881 -2000 KIDDE- FENWAL INC 74.234 10/99 °Kidde Fenwal Inc. Printed in USA 400 MAIN STREET, ASHLAND. MA 01721 TEL • (508) 881-2000 FAX (508) 881-8920 Effective: October 2007 Addressable Manual Pull Station �� .- Series 3300 F v Protection Systems F - - 1001 A UTC Fire & Security Company FEATURES - - -- - • Unique Field Labeling for either Fire Alarm or Suppression Applications \ ; , • Dual Action Operation ' FIRE • Interfaces directly with Fenwal Addressable Control Panel SLC Communication Loop I • FM Approved PUSH • cULus Listed for US and Canada • Other domestic approvals in process • Surface and Weatherproof Backboxes �'. PULL • Flashing LED 1 , • Keylock for Reset DESCRIPTION . The Fenwal Addressable Manual Pull Stations is an 1 intelligent initiating device that contains its own Smart- FENWAL OneTM Addressable Input (Al) module and interfaces .. , directly to the FenwaINET 2000 and 6000 control panel. '' The initiating device circuit is wired as NFPA Class B. , "° The Manual Pull Station is constructed of heavy die -cast aluminum for long life and uses an internal toggle switch ""'"" - - for reliable operation. e , Similiar to othe Smart One devices, the unit is field pro- ` 1'h� 0 grammable using the control panel keypad or Hand -Held • Programmer. The owner location message and reporting type can be customized by the use of a programming util- ' ity utilized with the control panel. A status LED is L' 4 4 •• mounted on the unit and indicates the status by a 2 or 9 • 9 t t second flash interval. A Trouble condition inhibits the sta- of ; II ,; �„ ;, i tus LED completely. A ' '" '11 J° a., , . i a While the Pull Station is designed for quick, efficient ; ' ;. .' I S emergency response, its double action PUSH /PULL r° el levers prevent accidental operation. = 1 ;j r 1 r , The Pull Station can be mounted in an indoor or outdoor f . weatherproof backbox (Model SBG -32S or Model SGB- ; 32C) or a North American 2 -1/2 in. (64 mm) deep single- / ` ' gang box. MI • The Station terminal block on the Al module accepts 14, i ,.._..,,_._.,...,,._,,,,.,, - 16 and 18 AWG (1.5 mm 1.0 mm and 0.75 mm n_ � wire. Size #18 is the minimum requirement. FIRE ALARM OR SUPPRESSION RELEASE LABELING - The Pull Station has a unique labeling method which pro- • FIRE ALARM • FM -200 RELEASE vides the installer the greatest amount of flexibility with- out the expense of having to carry extra inventory. Six • NOVEC 1230 RELEASE • FE -13 RELEASE • heavy -duty Lexan self- adhesive labels are shipped with FIRE SYSTEMS RELEASE • HALON RELEASE • each station: SPECIFICATIONS ORDERING INFORMATION Station Type: Double Action, with integral Smart- Part Number Description One Addressable Module • 30- 330002 -001 Addressable, Double Action Manual Pull Initiating Device Style B (Class B) Wiring Station — ships with mounting hardware, Circuit: 2 keys, 1 break rod, and label set. EOL Resistor Value: 10 K Ohm (06- 129025 -003) Max. Circuit 70- 407008 -001 Addressable Input Module (Normally Resistance' 50 Ohm (25 ohm per conductor) Open Devices) Max. Circuit 30- 195001 -001 SGB -32S Indoor Backbox Capacitance: 0.1 pF 30- 195001 -002 SGB -32C Outdoor Waterproof Backbox Operating Tempera- -40 °F to 150 °F ( -40 °C to 66 °C) ture Range: 06- 129025 -003 10 K Ohm Resistor Operating Humidity 0 -95% RH 30195002 -001 Pkg. of (12) Breakrods Range: 06- 118013 -001 Spare Key Construction: Die -cast metal housing 06- 231866 -931 Label Set Compatible Electrical Indoor: Sheet metal Model SGB - Boxes: 32S Outdoor: Weatherproof Die -cast Model SGB -32C DIMENSIONS Shipping Weight: 1.12 lbs. (510 g) 1 -5/64 In. (27 mm) 4 SGB -32S INTERIOR SURFACE BACKBOX I 3 -114 In. 1 _o. 31/32 in. (83 mm) (24 mm) Dimensions: 4 -3/4 in. H x 3 -1/4 in. W x 2 -1/4 in. D Construction: Steel sheet metal. Conduit: Two knockouts for 1/2 in. conduit IFlRECIFFlREi connectors, one on top and bottom. PUSH�� Mounting: Mounts to the box with (4) 8/32 4- 3/41n• } ■ screws, which ship with each box. ( mm) PULL I - SGB -32C WEATHERPROOF SURFACE II I J , U—J BACKBOX FENWAL j Q Dimensions: 4 -3/4 in. H x 3 -1/4 in. W x 2 -1/4 in. D 14 2 -114 In. MAX. (57 mm) Construction: Cast aluminum. Conduit: One threaded opening for 1/2 in. conduit connector. Mounting: Mounts to the box with (4) 8/32 screws and a foam gasket, which ship with each box. Fenwal is a registered trademark of Kidde - Fenwal, Inc SmartOne is a trademark of Kidde- Fenwal, Inc. FM -200 is a registered trademark of the Greak Lakes Chemical Corporation. 3M and Novec are trademarks of 3M. FE -13 is a trademark of DuPont. Lexan is a registered trademark of the General Electric Company. This literature is provided for informational purposes only. KIDDE - FENWAL, INC. b :' FE ` assumes no responsibility for the product's suitability for a particular application. The prod- uct must be properly applied to work correctly .- Protection Systems If you need more information on this product, or if you have a particular problem or ques- A UTC Fire & Security Company Lion, contact KIDDE - FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881 -2000 400 Main Street Ashland, MA 01721 F -30 -1001 Rev AA © 2007 Kidde - Fenwal Inc. Printed in USA Ph 508 881 2000 Fax. 508 881 8920 www fenwalfi,n rnm Effective: May 2007 Series 1930 Suppression System -'\d FENIAIAI.." Abort Station 1 � �`� Protection Systems A UTC Fire & Security Company • F -30 -050 FEATURES . ;,, �. n ; �,� • UL Listed, File # S3743 - A 4 _ A � • Flush or Surface Mount � pw . • Sized for Double Gang Box ` q� • Large Yellow Push Button Switch „,,, p . • One Normally Open Contact • DESCRIPTION U S N g . OLD The Fenwal Series 1930 Abort Station features a large, -. easy -to- operate abort push button. The momentary type :. �- • uPPAFS systEV 4eoRr switch is very easy to see due to its highly visible yellow • FENL, • color. The abort station stainless steel faceplate is clearly labelled with operation procedures — eliminating indeci- { sion and hesitation. i .'' ,""` " R �. r;.. . The Backbox is painted with red enamel and is provided with four 1/2 -inch knockouts. The pre - drilled and tapped mounting tabs allow for easy attachment of the abort station. TECHNICAL SPECIFICATIONS I,I 4 -112 in. - 1 (114 mm) Electrical Ratings: . ' ' I.: - , One normally open momentary contact rated 2.5 Amps 0 B 11. .11 120 Vdc • Ambient Temperature: 4-1/2 in PUSH/ -13 °F to 158 °F ( -25 °C to 70 °C) (114 mm) HOLD Terminals: SUPPRESSION SYSTEM ABORT —1 4 1-11/16 In. Captive screws and saddle clamps accept 14 AWG to (9 FENWAL ® (43 mm) 24 AWG wire / ` 3-3/64 In. (77 mm) Mounting: 2-1/4 in. Four 6 -32 x 1/2 -inch mounting screws included (57 mm) 102 mm mm ORDERING INFORMATION • O • Part Number Description Shipping - Weight O A 30- 193000 -001 Abort Station 2 lb. (.9 kg) e" cy O 30- 193000 -002 Abort Station with Back- 3 Ib. (1.4 kg) box ,1) 30- 193000 -003 Backbox 1 lb. (.45 kg) e Figure 1. Dimension Details This literature is provided for informational purposes only. KIDDE - FENWAL, INC. assumes Fenwal Protection Systems no responsibility for the product's suitability for a particular application. The product must be A UTC Fire & Security Company properly applied to work correctly. 400 Main Street If you need more information on this product, or if you have a particular problem or question, Ashland, MA 01721 contact KIDDE - FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881 -2000. Ph: 508.881.2000 F -30 -050 Rev AC © 2007 Kidde- Fenwal Inc. Printed in USA Fax: 508.881.8920 www.fenwalfire.com rc' ^ 'srr b r � t ,fx r ' � 'Vii'; '' �, +' ,hL $A ,. a`S 1 ', ,er ` + -�`.a. S , �i .&s. ,w.t.ds�S"•� -- GTENsTE # ;.: 1 5/ 1 Z : `,. kt n� �� C O P O 1-(4,* T 1 O N � . .°" + - �' .w.. h x L +�`, ;: ; ,,E�r r .r>! si g � sa �a ,� � ,.t� r,a;' i � r- d v ti v.� °a � H Smarter�Vi Commander Series Emergency GEC3 /GES3 Notification Evacuation Signals Colored Lens Applications The Commander Series Emergency Notification Evacuation Signals is a wall S E R I E S mount, low profile strobe or horn /strobe combination that offers dependable audible and visual alarms for warning and emergency notification. Applications include severe weather, evacuation, emergency response and many more $4 The GE3 Emergency Notification Series are 24VDC units available in lens I ( �iti colors of Amber, Blue, Green and Red. The Series offers tamperproof field selectable candela options of 15, 30, 60, 75, and 110 candela. The Commander Emergency Notification Evacuation Series has a minimal i operation current and has a minimum flash rate of 1Hz regardless of input�� voltage. The Commander Emergency Notification Series is shipped with a die cast 4" mounting bracket which incorporates the popular Super - Slide M feature that allows the installer to easily pre -wire the system and test for supervision. The product also features a locking mechanism that secures the product to the bracket without showing any screws. , The Emergency Notification Series also features the Checkmate - Instant Voltage Verification Feature which allows the installer to check the voltage ! • "a ° drop, current draw and match it against the blue print. //4," ,, � The Commander Emergency Notification Evacuation Series are UL1638 and UL464, listed and are warranted for three years from date of purchase. Lens available in Blue, Red, Amber and Green Colors Standard Features • Nominal Voltage - 24 VDC • Tamperproof Field Selectable Candela Options of 15, 30, 60, 75, and 110 product Listings • Unit Dimensions: 5" high x 4.5" wide x 2.5" deep • Super-Slide TM Bracket - Ease of Supervision Testing • Checkmate TM - Instant Voltage Verification t0� • Synchronize Strobe and Horn by Using the Gentex Synchronization Module �t TI..yrEtl an ere preeu7a rmeop.m MOM . r. • Prewire Entire System, Then Install Your Signals l,zhd W uNoeRwRRERS UBORATOPoES INC • • Input Terminals 12 to 18 AWG BS +A/MEA (Pending) • CSFM 7135 - 0569135 (GECA24, • Switch Selection for High or Low dBA GECB24, GECG24 & GECR24) • Switch for Chime, Whoop, Mechanical and 2400Hz Tone 7135- 0569:136 (GESA24, • Switch for Continuous or Temporal 3 (not available on whoop tone) GESB24, GECG24 & GECR24) • Tamperproof Re- entrant Grill • UL Listed 464, 1638 • Surface Mount with the GSB ( Gentex Surface Mount Box) i • Silence Horn While Strobes Remain Flashing XENIA • Wide Voltage Range 16 -33 VDC or FWR MEMBER At,,,,„ Fp W TlIE uSA • Faceplate Available in Red or Off -White • GES3 Emergency Notification Evacuation Strobe, Selectable Candela Low Profile Model Number Part Number Lens Color Nominal Voltage Candela ' GESA24PWR 904 -1335 -002 Amber 24 VDC 15, 30, 60, 75, 110 =raga= WI II IFc Icidre0 ENO= MailiIIM MUMA =NM=InIsL•!siKIcY aki = , T IIsZ•ikadi><:I! r I[' ela.`i:PZl:MOM WM51003•IeRM Z[UIII •I TsinfoR .`�IUa • 'el a.YcloZ RATA :i_ ormINIMINIITPM Mal= 11.1 UAM - c . - : i e1a.Ye;•ZfwJ fur_ ourgi [IEII'J limZ[UI1I aIi l igrall 1• - , •11- •8 • -II • e. 'rI I . • S "ESH24PWW 904- 1342 -002 Red 24 VDC 15, 30, 60, 75, 110 GEC3 Emergency Notification Evacuation Horn /Strobe, Selectable Candela Low Profile Model Number Part Number Lens Color Nominal Candela - Reverberant In Anechoic Voltage dBA @ 10ft. Room dBA 1 Per UL 464 @1011. GLCA24PWR 904 - 1327 -002 Amber 24 VDC 15, 30, 60, 75, 110 62 -82 100 tiECA24PWW 904 - 1328 -002 Amber 24 VDC 15, 30, 60, 75, 110 62 -82 100 - 1 1 - •I •-.. : , t•D 5 , .I , I • -. SI GECB24PWW 904- 1330 -002 B ue 24 VDC 15, 30, 60, 75, 110 62 -82 100 GECG24PWR 904 - 1331 -002 Green 24 VDC 15, 30, 60, 75, 110 62 -82 100 .iEGG24PWW 904 - 1332 -002 Green 24 VDC 15, 30, 60, 75, 110 62 -82 100 'ECH24PWR 904 - 1333 -002 Hed 24 VDC 15, 30, 60, 75, 110 62 -82 100 GECR24PWW 904 - 1334 -002 Red 24 VDC 15, 30, 60, 75, 110 62 -82 100 Notes: • The GE3 Emergency Notification Evacuation Series is not listed for outdoor use. • Operating temperature: 32 °to 120 °F (0° to 49° C). • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products ' (see Technical Bulletin Number 014). Model designations: "P" = Plain (no lettering), "W" = Wall Mount, "R" = Red Faceplate / "W" = Off -White Faceplate Lens Colors: "B" = Blue "R" = Red "A" = Amber "G" = Green Horn Mode Minimum dBA Minimum dBA Regulated 24VDC 10ft. per @ 10ft. per Max. Operating UL464 (HIGH) UL464 (LOW) @ High Setting (mA) Emergency Notification Evacuation Strobe Current Ratings lemporal 3 2400Hz 78 71' 28 Candela 15cd 30cd 60cd 75cd - 110cd lemporal 3 Mechanical 76 70' 25 24 VDC 74mA 88mA 134mA 156mA 199mA lemporal 3 Chime 70' 66' 15 UL Max2 113mA • 134mA 212mA 253mA 346mA t;ontmuous 2400Hz 81 74' 28 Continuous Mechanical 80 72' 25 Continuous Chime 70' 66' 15 Whoop 82 69' 56 'Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). Notes: The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. To obtain the horn /strobe current draw, add the strobe current draw and the horn current draw. 1 The listed reverberant dBA are for the continuous tone mode. The Temporal 3 tone has a reverberant dBA @ 10ft. per UL 464 is 77 -83. with a horn current draw of 34mA. ▪ 2 RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16 -33VDC for 24VDC units) (8 -17VDC for 12VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units) (8VDC for 12VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Switch Locations Mounting Super - Slide'" SWITCH POSITION 3 4 5 a Mechanical ON ON ON w �� w Mechanical -Cont OFF ON ON W Temp ON OFF ON ` \\ Hi OFF OFF ON I l \ r r Ch ime Temp ON ON OFF i,\ * 9A t o Chnne -Cent OFF ON OFF Whoop ON OFF OFF J,\ ^ 1 p Whoop OFF OFF OFF It- M ar 1lIIL 11 ij r I II / � Sw itch po sitions 1 and 2 11 1 I it / , IJ L� in the Off posihon to select \S isolated horn a strobe I '') _ III �� power Inp uts Die Cast Metal Mounting Plate: Mounts to single gang, r wwwwww double gang 4" square boxes or GSB box. l l !sue l lit Checkmate'" - Instant Voltage Verification 1 ��(P 1 2 3 4 5 6 X 1111111119 lillk lik III-- Candela Selection ■ _ I-1 - ; «;=�� , II k! Candela selection slid I I y . „..._ AIR • and s fa,nlich de Depswttchto ress centerdesved ` ■ \ • brightness level LI I 111 (+ �I , VI ��� I Break off pin and insert into �I,II �r ((MMryry �� ., � hole at the bottom of the I „ The access holes are provided in the back of the terminal selector to lock candela setting I I Signal must be removed from1�� • i III block to allow the voltage to be measured directly without bracket and pm pushed forward from backside out of hole r removing the device. Typically this would be done at the to change candela f 1 ` end of the line to confirm design criteria. Most measure- =":. ments will be taken using the S+ and S- locations I �� , 1 although access is provided to other locations. NOTE: ' �) Care should be taken to not short the test probes. x ;,- ..■.. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Signal Signal Control Signal Signal Panel Panel 9 9 S+ 5+ 5 Ho H S+ S. S. H. H S+ S+ S- H+ H- S+ S+ S- H+ H- Supervised O r��i .��. F �� r`.� r��. 1 Supervised 19 S IS GI . . . ® 0 Signal Circuit IIlIII 111111 Signal Cicult / ” \ (V I"' 11111 END OF E RESrS10R \ in END LIRE o II II REE RESISTOR O O END OF LINE \ RESLSTOR 0 • Wiring Diagram Emergency Notification Series with Gentex Synchronization Module F.A.0 P. END OF LINE RE cuss t FOR + TO NEXT SIGNAL TO NOTIFICATION ALARM CIRCUIT TO NEXT SIGNAL ; TO NOTIFICATION ALARM CIRCUIT REMOVE JUMPER � /6 I FODE PENDENT l Z' 00 AUDIBLE SIGNAL`-'* — END OF UNE S R IN AND HORN OPERATION RESISTOR FOR CIRCUIT QASSe SYNCHRONIZATION �_ YARNS LEAVE JUMPERIN PLACE f TO ELIMINATE NEED FOR MODULE LEAVE JUMPER IN PLACE ON lmm dolma ® HORN INPUT ON AVSM / SLAVE UNITS UNLESS SEPARATE -a 1J AND OPERATE SIGNAL CONTROL OVER HORN CKT - yyy • M •II \ / IN UNISON MODE EN 1 Z Z �r [G!/ L 1. IS REQUIRED. SYNCHRONIZATION MODULE Signor signal m.irt°. ra• am.Im S. S+ S- H+ 14- S. S. S- He H- p� " Is se el IS S 0 VISIBLE SIGNAL ',+ ■■ I i i i RESISTOR OF NE FOR CIRCUIT _ I I I I Cruse m r I I / // - -- WIRING ONLY II I 1 IL I END OF UNE + __— • __ i_t RF CLASS CST0R FOR WD@ID ONLY Note: See Technical Bulletin 015 for proper synchronization module for application. Architect & Engineering Specifications: The audible and/or visible signal shall be Gentex GE3 Emergency Notification Evacuation Series or approved equal and shall be listed by Underwriters Laboratories Inc. per UL 1638 and UL 464. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible /visible) shall produce a peak sound output of 100dBA or greater as measured in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be syn- chronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible /visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2 Hz regardless of power input voltage. The appliance shall have an operating current of 74mA or less at 24 VDC for the 15Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with termi- nals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate. The unit shall have an input voltage range of 16 -33 volts with either direct current of full wave rectified power for 24 volt models. The appliance shall be capable of testing supervision without disconnecting wires. Also the appliance shall be capable of mounting to a surface back box. The unit shall also be able to verify voltage at the unit without removing unit. 24 units per carton 28 pounds per carton Imporanl Notice • These materials have been prepared by Genies Corporation (•Gentea) for mton an natal purposes only. are 551- 0045 -01 G E N T E X necessariy summary. arnd are net purpoded serve as legal advl and should rot be used as ouch Genies Geea makes no representations and warranties, express or mmisled, e d, that these materials are Corrrplete CORPORATION and accurate, ts.date, or in compliance with as relevant local, state and federal laws, regulations and rules The materials do not address all legal considerations as there is inevitable Iancertamy regarding interpretation of laws, regulations and rules and the apphcatlon of such laws, regldaltons and rules to partic- ular fact patterns. Each person's Dctrvgres Can dMerenty affect the obtlgalsons that exist under applicable Fire Protection Products: www.gentex.com laws, regulations or rules Therefore, these materlas should be used only for informational purposes arid 10985 Chicago Drive Box 310 • Zeeland, Michigan 49464 should not be used as a sub: htute for seekin professional legal advice. w not be responsible for 9 g ar ectron or failure to am m rellar c Q On the mformatna O or sartned In this Gentex matelot il 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax Gentex corporation reserves the light to make changes to the product data sheets at their dsoetwn 0 Printed on Recycled Paper I-;./.Y,). ,` -, 1 . 1r `v V - )t., '.J 1 27i 1 2V 7Mh(2O.h The rechargeable batteries are lead -lead dioxide systems. The dilute sulfuric add - electrolyte is absorbed by separators and plates and thus Immobilized. Should the r • ti; . battery be accidentally overcharged producing hydrogen and oxygen, special one- '. `' r way valves allow the gases to escape thus avoiding excessive pressure build -up. Otherwise, the battery is completely sealed and is, therefore, maintenance -free, °` == -^"._ 5 ' --- ''-..- leak proof and usable in any position. `.... ' 1-:- • , Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid I General Features Performance Characteristics . Absorbent Glass Mat (AGM) technology Nominal Voltage - - - - - - . • - . • • • • • • - - • • 12V for efficient gas recombination of up to Number of cell 6 99% and freedom from electrolyte Design Life 3 -5 years maintenance or water adding. • Not restricted for air transport- complies Nominal Capacity 77°F(25°C) with IATA/ICAO Special Provision A67. 20 hour rate (0.36A, 10.5V) 7.2Ah • UL- recognized component. 10 hour rate (0.69A, 10.5V) 6.9Ah . Can be mounted in any orientation. 5 hour rate (1.16A, 10.5V) 5.8Ah • Computer designed lead, calcium tin alloy 1 hour rate (4.8A, 9.6V) 4.8Ah grid for high power density. Internal Resistance . Long service life, float or cyclic Fully Charged battery 77oF(25 • - • - • 22mOhms applications. Self- Discharge . Maintenance -free operation. 3% of capacity declined per month at 20 . Low self discharge. Operating Temperature Range Discharge - 20 -60°C Dimensions and Weight Charge - 10 -60 _ Length(mm / Inch) 151 / 5.94 Storage - 20 -60 Width(mm / Inch) 65 / 2.56 Max. Discharge Current 77°F(25°C) 105A(5s) Height(mm / Inch) 94/ 3.70 Short Circuit Current • 350A - Total Height(mm / inch) 100 / 3.94 Charge Methods: Constant Voltage Charge 77 °F(25°C) Approx. Weight(Kg / lbs)• . • . • 2.5 / 5.51 Cycle use - 14.5 -14.9V Maximum charging current . . . • • • • • 2.88A Temperature compensation • - . • • • • • 30mVMC i;i ti - i Standby use 13.6 -13.8V L Temperature compensation - 20mVI°C , 1 ' I I��I I : T Discharge Constant Current (Amperes at 77 °F25 °C) r End Point - Smin 10mtn 15mIn 1h 3h 5h 10h 20h Volts/Cell 1.60V 30.0 18.8 15.3 8.50 4.80 1.88 1.29 0.71 0.38 1.65V 28.4 j 17.9 1 14.61 8.15 4.63 1.82 125 0.70 0.38 1.70V 26.8 17.0 13.9 7.86 4.44 1.76 120 0.70 '' 0.37 1.75V 252 16.0 13.2 7.56 4.25 1.69 1.16 0.69 0.36 II n1 Discharge Consta t Power (Watts at077°F25 °C) 1.12 0.67 0.35 End Point 5min 10min 15mIn 1h 2h 3h 5h re eti r .8 0. 8 Volts/Cell 1.60V 53.3 35.8 28.1 15.5 11.8 9.30 5.13 3.68 2.38 oo 1.65V 50.7 34.0 27.0 14.9 11.3 8.90 5.02 3.59 2.34 1.70V 48.1 32.2 25.9 14.3 10.8 8.53 4.89 3.49 2.30 1.75V 45.6 30.4 24.8 InIT.T 10.4 ' 8.28 4.73 3.38 2.25 - 1.80V 43.1 28.8 23.8 13.2 10.0 4.58 3.27 2.19 1 proi MI 1',mina' lopt livid) n (0. IV) F2 (0.50) rng JOB NAME: DOW AGRO SCIENCES SYSTEM TYPE: FM -200 PROTECTED AREA: SERVER & LAN ROOMS AC Branch Circuit Requirements 120 VAC Control Panel 1.3 1 1.3 , Power Supply Module 1.9 1 1.9 Minimum Requirement is 15 Amps I AC Branch Current Total Amp Load 3.2 System Standby Power Requirements Standby Module / Max Standby Current (Amps) System Current (Amps) Modules FenwaINET 6000 Control Panel 0.2000 1 0.2000 Field Devices PSD -7152 Photoelectric Detector 0.0005 4 0.0018 NI Addressable Contact Input N/O 0.0005 4 0.0018 NO Addressable Relay Output 0.0004 2 0.0008 ASM Addressable Signal Module 0.0005 2 0.0010 Standby Load Amps 0.2054 System Alarm Power Requirements Alarm Module / Max Alarm Current (Amps) System Current (Amps) Modules FenwaINET 6000 Control Panel 0.6500 1 0.6500 . #1 Releasing Circuit Supervision 0.2000 1 0.2000 #2 Releasing Circuit Supervision 2.0000 1 2.0000 #1 Notification Circuit Supervision 0.1620 1 0.1620 • #2 Notification Circuit Supervision 0.0880 1 0.0880 #1 Auxiallary Power Output 1.0000 1 1.0000 Field Devices 0.0000 PSD -7152 Photoelectric Detector 0.0004 4 0.0018 NI Addressable Contact Input N/O 0.0004 4 0.0018 NO Addressable Relay Output 0.0004 2 0.0009 ASM Addressable Signal Module 0.0004 2 0.0009 Alarm Load Amps 4.1053 Total Battery Capacity Required Current (Amps: (x) Factor Total Standby Load Required Standby Time (24,60,90) Min. 0.2054 24 4.9296 Total Alarm Load Required Alarm Time (5 Min = 0.084) OR (10 Min = 0.167) 4.10528 0.084 0.3448 Amp Hours Required 5.2744 Total Amp Hours Required 5.2744 • Effective: May 2007 • FM -200® / . FENIIIIIAL • Fire Suppression Agent �� `�' Protection Systems A UTC Fire & Security Company F -93 -1900 FEATURES Approvals: FM -200 agent complies with the NFPA Stan- dard 2001, Standard for Clean Agent Fire Extinguishing • Non -Ozone Depleting Systems, EPA SNAP Program, (Significant New Alter- • Safe for Total Flooding of Occupied Spaces nate Policy), Underwriters Laboratories, Inc. (UL) Factory • Clean -No Residue to Clean Up Mutual Research Corporation (FMRC). • Non - Damaging to Hazard Contents • Fast Acting Use: FM -200 is used in total flooding fire suppression systems. It is stored in steel containers, and is super- • Active Fire Suppression Agent pressurized with nitrogen to aid in expelling the agent. • UL Component Recognized The discharge time is 10 seconds or less. The maximum • FM Approved fill density of the agent storage is 70 Ib. /ft.3. EXTINGUISHING AGENT FM -200 (1 ,1,1,2,3,3,3- heptafluoropropane) is a com- FM -200 Physical Properties pound of carbon, fluorine and hydrogen (CF3CHFCF3). It Chemical Formula CF3CHFCF3 is colorless, odorless and electrically non - conductive. It suppresses fire by a combination of chemical and physi- Molecular Weight 170 03 cal mechanisms without affecting the available oxygen. Freezing Point -204 °F (- 131°C) This allows personnel to see and breathe, permitting Boiling Point at 1 Atm. 2 6 °F ( -16 4°C) them to leave the fire area safely. FM -200 has acceptable toxicity for use in occupied spaces when used as speci- Critical Temperature 215.1 °F (101.7 °C) fled in the United States Environmental Protection Critical Density 38.76 lb /ft 3 (621 kg /m3) Agency (EPA) Significant New Alternative Policy (SNAP) Critical Pressure 422 PSIA (29.0 bar absolute) program rules. Although FM -200 is considered non -toxic to humans in concentrations necessary to extinguish Critical Volume 0.0258 cu ft/Ib. (1.61 Ukg) most fires, certain safety considerations should be Ozone Depletion Potential o - observed when applying and handling the agent. The dis- charge of FM -200 may create a hazard to personnel from the undecomposed agent itself and from the decomposi- FM -200 Fire Protection Properties tion products which result when the agent is exposed to fire and other hot surfaces. Exposure to the agent is gen- Cup Burner Concentration (n- Heptane) 6.70% v/v erally of less concern than is exposure to the decomposi- Use Concentration for n- Heptane 8.00% v/v tion products. Unnecessary exposure to the agent or the decomposition products should be avoided. Use Concentration for Acetone 8.30% v/v Toxicity: In tests, the acute toxicity of FM -200 was Use Concentration for Isoproparml 9.00% v/v shown to be equivalent to that of Halon 1301. FM -200 Use Concentration for Toluene 7.00% v/v has been evaluated for cardiac sensitization through test Use Concentration for Class A (Surface Fires) 6.25% v/v protocols approved by the US EPA. The EPA's SNAP Program classifies FM -200 as acceptable for use as a total flooding agent in occupied spaces. Refer to the FM -200 Toxicity Properties SNAP program rules for more information. NOAEL 9.00% Cleanliness: FM -200 is clean, leaves no residue, (No Observable Adverse Effect Level) thereby eliminating costly after -fire clean -up, and keeping LOAEL expensive "down- time" to a minimum. Most materials (Lowest Observable Adverse Effect Level) 10.50% such as steel, stainless steel, aluminum, brass, and other - - metals as well as plastics, rubber and electronic compo- nents are unaffected by exposure to FM -200. FM -200 is a Registered Trademark of Great Lakes Chemical Corporation This literature is provided for informational purposes only. KIDDE - FENWAL, INC. assumes Fenwal Protection Systems no responsibility for the product's suitability for a particular application. The product must be A UTC Fire & Security Company properly applied to work correctly. 400 Main Street If you need more information on this product, or if you have a particular problem or question, Ashland, MA 01721 contact KIDDE - FENWAL, INC., Ashland, MA 01721 Telephone: (508) 881 -2000. Ph: 508.881.2000 F -93 -1900 Rev AB © 2007 Kidde - Fenwal Inc. Pnnted in USA Fax: 508.881.8920 www.fenwalfire.com • • FM -200 COMPONENT DESCRIPTION Effective February 2001 Cylinder and Valve Assemblies 10LB (4.5 KG) - 70 0 • LB (31.7 KG) Capacity, Vertical Mount Only FE111Wikl." • . F -93 -2010 Features • For use with UL Listed, ULC Listed & FMRC approved systems • CYLINDER VALVE 11/ � SAFETY CAP NOTES: ; 1/41 1. THE SAFETY CAP MUST BE INSTALLED ON THE VALVE OUTLET AT ALL TIMES EXCEPTWHEN THE CYUNDERS ARE = CONNECTED TO THE SYSTEM PIPING OR BEING FILLED. THE SAFETY CAP MUST NOT BE REMOVED FROM ITS CHAIN. 2. SEE F -90 -2070 FOR ADDITIONAL INFORMATION. 3. CYUNDERS ARE VERTICAL MOUNT ONLY. SYPHON TUBE C ORDERING INFORMATION CYLINDER B Dimensions • Part Number Cyl. Size At B* C* • A 93- 100010 -001 . 10 Lbs. 7.07 13.34. 17.30 ' 93- 100020 -001 20 Lbs. 7.07 21.01 24.97 93- 100040 -001 40 Lbs. 9.00 22.80 26.76 93- 100070 -001 70 Lbs. 9.00 34.87 38.83 * Dimensions are in inches. •• • • MATERIALS P /N: 93- 10000X0 -001 • VALVE BODY: BRASS CYLINDER: STEEL, PAINTED RED • . • • • • 1j This literature is provided for informational purposes only KIDDE - FENWAL,INC assumes no • p \ / responsibility for the product's suitability for a particular application. The product must be FENINAL your applied to perform es herein. If need ' \ \-'), ' If you n more information on this on this product, uct, or if you have a question, contact KIDDE- • SSqE.FENW. uc FENWAL, INC., Ashland, MA 01721, Telephone (508) 881 -2000 NATM STREET A51LLAND NA 01721 TEL TEL 130!1011 2000 FA11 i 001001a220 • Ranco Systems F- 93-2010 02001 Kidde- Fenwal, Inc. Pnnted in U S.A • • Effective: May 2007 FM -200 Component Description- FE Electric.Control. Head, Stackable Explosion Proof Protection Systems A. UTC Fire & Security Company F -93 -8017 • FEATURES • For use with UL Listed, ULC Listed & FMRC Approved Systems 2.90" 1.25 -18 UNEF -2A CONNECTION � F t F / 112" -14 NPT • CONDUIT CONNECTION ELECTRIC CONTROL HEAD, PART • • NO. 486500-01 IS RATED FOR USE - IN HAZARDOUS (CLASSIFIED) _ LOCATIONS CLASS 1, DIV..I, GROUPS C, D AND CLASS II, DIV. II, 5.28" GROUPS E, F, G BETWEEN • -40F AND 140F. USE CONDUIT SEAL WITHIN 18 IN. (45cm) OF THIS DEVICE. • (3) 18 AWG -LEADS 18" LONG • SWIVEL NUT 1.25 -18 UNEF -2B CONNECTION Note: This control head is polarized. Improper wiring will VOLTAGE:24 VDC result in failure of this device to operate. CURRENT:0.2A CONTINUOUS DRAW Electric control head, P /N: 486500 -01, is P /N: 486500 -01 designed for installation directly on 487 Series Halon and Model 9300 fm -200 valves only. This control head must not be installed on any other type of halon or FM- . 200 cylinder valve, nitrogen valve, carbon WARNING dioxide cylinder valve, FE -13 cylinder valve or Stop (Directional) valve. Installation of this control head to any other device (e.g., pressure operated control head) will result . in failure of device to operate. FM -200 is a Registered Trademark of Great Lakes Chemical Corporation. • This literature is provided for informational purposes only. KIDDE - FENWAL, INC. assumes Fenwal Protection Systems no responsibility for the product's suitability for a particular application. The product must be •A UTC Fire & Security Company properly applied to work correctly. - 400 Main Street If you need more information on this product, or if you have a particular problem or question, Ashland, MA 01721 contact KIDDE - FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881 -2000. Ph: 508.881.2000 F -93 -8017 Rev AB © 2007 Kidde- Fenwal Inc. Printed in USA Fax: 508.881.8920 • www.fenwalfire.com • FM -200 COMPONENT DESCRIPTION Effective June 1999 Valve Outlet Adapters FENimmL) F -93 -2100 FEATURES • FOR USE WITH UL LISTED, ULC LISTED 8 FMRC APPROVED SYSTEMS B (VALVE OUTLET CONNECTION) 0 D C 1 1 $ l A (SYSTEM PIPE CONNECTION) ORDERING INFORMATION PART NO. SIZE A* B* C* D* 283904 1-1/2 1-1/2" NPT 1 '874 2.69 2.50 HEX 12UNJ 283905 2 2" NPT 2.500 3.12 3.00 HEX 12 UNJ 283906 2 -1/2 2 -1/2" NPT 3.000 3.00 3.75 HEX 12 UNJ MATERIAL: BRASS NOTE: FOR DIRECT CONNECTION OF CYLINDER VALVE TO DISTRIBUTION PIPING. P/N: 28390X • This literature is provided for informational purposes only KIDDE - FENWAL,INC. assumes no responsibility for the product's suitability for a particular application. The product must be FECAL / \� properly applied to perform as descnbed herein. If you need more information on this product, or if you have a question, contact KIDDE- 1 ` , J FENWAL INC., Ashland, MA 01721; Telephone (508) 881 -2000 1o00ESCNW*2— C 00 ( 5 ll.2 ,ASHAI W01 .0 TEL MO eDl•r000 FAX U'OCI091AA FENINAI: F- 93- 2100 ©1999 Kidde- Fenwal, Inc. Printed in U.SA PPr t000000 Systems FM -200 COMPONENT DESCRIPTION Effective June 1999 • • 0 Cylinder Mounting Straps FENNjui. F -93 -8130 • • FEATURES • FOR USE WITH UL LISTED, ULC LISTED 8 FMRC APPROVED SYSTEMS • • E • • A• • (HOLE SIZE) C . • • PART NO. CYL SIZE CYL O.D. ' A* B' C' D* . E* F' 283945 10,20 7.07 6.48 9.62 8.62 1.00 2.78 .437 283934 • • 40,70 9.00 8.16 11.69 10.69 1.00 3.50 .437 235317 125,200 12.75 12.93 16.18 14.56 1.75 5.59 .625 292971 200 pre3 /98 13.60 13.09 17.06 15.44 1.75 6.06 • .625 281866 350 .16.00 15.50 19.50 17.88 1.75 7.25 .625 • 294651 600 22.00 21.56 25.75. 24.12 1.75 10.25 .625 DIMENSIONS ARE IN INCHES • MATERIAL: STEEL, PAINTED BLACK SAE 1020 This literature is provided for informational purposes only. KIDDE - FENWAL,INC. assumes no FENWAL: / \� • responsibility for the product's suitability for a particular application. The product must be properly applied to perform as described herein. II you need more information on this product, or if you have a question, contact KIDDE- 1000ESEnwu we • 00 YAM STREET.. A .1 WOIY11 FENWAL, INC., Ashland, MA 01721; Telephone (508) 881 -2000 ' TEt (500)001.2000 F. OM E014020 ...rm�� woroc F -93- 8130 ©1999 Kidde-Fenwal, Inc. Pnnted in U.S.A. • • Effective: May 2007 Spherical Agent Storage Container - - ",FE AL • FM -200 Agent Storage Container ` ' Protection Systems P /N: 93 - 11020X - 001 A UTC Fire & Security Company F -93- 1120.1 FEATURES • 4 Convenient Sizes • 20 to 196 Pound Capacities • UL Listed, FMRC Approved • Requires No Floor Space • Electric Initiator Actuation DESCRIPTION Fenwal Modular Spherical Agent Storage Containers store FM -200 super - pressurized with dry nitrogen to 360 psig at 70.F. These containers hold from 20 to 196 pounds of FM -200 and are equipped with a burst disc type discharge valve, a replaceable initiator well a screen assembly, safety plug and cable assembly. Each container has two identical boss - mounted check valves which will accept a pressure gauge (standard), and an optional pressure switch (see Data Sheet 93.3119.0). Either of these check valves may be used for recharging 2. Check all component supporting hardware and the container. tighten or repair as required. Initiator assemblies must be ordered for each container. 3. Visually check all components for physical abuse See Data Sheet 93.1932.0 and take whatever action is necessary. Replace the OPERATION component if at all in doubt as to its ability to perform " The container is discharged when the initiator is actuated properly. to rupture the burst disc valve. INSTALLATION B. SEMI - ANNUAL INSPECTION The container must be rigidly mounted in position with Qualified personnel are to remove and weigh all agent the valve facing down. Fenwal mounting brackets provide storage containers. Losses of agent must not exceed 5% a secure means for wall mounting containers. A lifting in net weight, or 10% reduction of pressure (adjusted for ring on the container provides a means for raising the temperature). Container and agent weight are marked on container to its mounting location. the container's nameplate. After the container is secured in place, remove the safety All outlet piping must be clean and free of dirt, chips, fill - plug and connect the rest of the piping and nozzles(s) ings and other foreign material that may become hazard - specified in the system drawing. Retain the safety plug ous projectiles or cause the system to become for use when reconditioning the container and whenever inoperative or ineffective at the time of the discharge. a filled container is moved. Note: The safety lug shipped with this container should MAINTENANCE be retained and secured to the container when - Inspection and /or maintenance procedures should be ever the piping is removed from a charge con - scheduled as listed below, or performed when an event tainer. Charged containers must have the occurs which might affect the reliability of the system. safety plug installed when removed from the A. QUARTERLY INSPECTION system for shipment. Observe proper han- 1. Check the pressure gauges of each agent storage dling procedures when installing or removing container. If the pressure is less than 325 psig at 70.F the initiator. (22.9 Kg /cm= at 21.C), the container should be removed and carefully inspected by qualified person- nel. It should then be reconditioned, recharged or • replaced depending upon its condition. Pressure var- ies with temperature, and in the range of 55.F to 85.F (12.7.C- 29.40C) this change is approximately 3pse /.F (.38 Kg /cm= /OC). RECONDITIONING Sphere After a system has been actuated, it is recommended that the local authorized Fenwal Distributor be contacted Part No. Diameter Height` Empty WT** for reconditioning the system. IN mm IN mm LB Kg • The Reconditioning Kit for this unit is P/N 31- 193005 -001 93- 110201 -001 13.2 334 zo 7 525 ze s 12 s This kit does not contain the initiator, which must be ordered separately. 93- 110202 -001 14.8 377 22.4 569 36.7 16.6 ARCHITECT /ENGINEER SPECIFICATIONS 93- 110203 -001 173 439 24.9 634 52.0 23.6 The agent storage container shall be a Fenwal modular 93- 110204 -001 21.5 547 29.3 745 991 45.0 spherical (refillable) container constructed of high *Height is from top of lifting ring to bottom surface of strength, low HSLA alloy steel. It shall consist of: fill flange. Flange mounting holes 5/8 in. (15.9 mm) diameter check valve, burst disc valve assembly, integral support- located on bolt circle 6 -5/8 in. (162.3 mm) diameter. ing flanges, 0 -700 psig pressure gauge and pressure Flange is 1.4 in (6.4 mm) thick for all models except for switch assembly (optional). The containers shall hold 90-110204-001, which is 3.8 in. (9.5 mm). from 20 to 196 lbs. of FM -200 agent. Containers shall conform to too applicable specifications **Average weight for shipping and mounting planning. of Dept. of Transportation, Underwriters Laboratories, Actual weight stamped on each unit. and Factory Mutual Research Corp. Fill Range Capacity The burst disc valve assembly shall be an integral part of Part No. the agent storage container and shall be operated by LB Kg Ft m applying electrical current to an initiator assembly, which has a electro- explosive device that provides an instanta- 93- 110201 -001 20-44 9.1 -20 656 .019 neous full bore release and discharge of the agent on 93- 110202 -001 28 -63 12.7 -29 932 .026 demand. The releasing mechanism shall contain no mov- ing parts. 93- 110203 -001 45-101 20.3 -46 1 488 .042 Filled containers shall be super - pressurized with dry 93- 110204-001 85-196 386-89 2.833 .080 nitrogen to 360 psig at 70°F to aid in rapid agent distribu- tion, particularly at lower temperatures. It shall automati- cally relieve between 850 to 1000 psig in the event of - excessive pressure build -up. Releasing devices and connecting leads shall be com- pletely supervised. The mounting bracket shall be designed for installation on a wall, floor or other rigid surface and shall serve as support for the agent storage container, and shall be capable of withstanding a thrust of 1000 lbs. For 5 sec- onds in any direction. FM -200 is a Registered Trademark of Great Lakes Chemical Corporation. This literature is provided for informational purposes only KIDDE - FENWAL, INC. ` FE - assumes no responsibility for the product's suitability for a particular application. The prod- \ c=% Protection S stems uct must be properly applied to work correctly y If you need more information on this product, or if you have a particular problem or ques- A UTC Fire & Security Company lion, contact KIDDE - FENWAL, INC , Ashland. MA 01721 Telephone: (508) 881 -2000. 4 00 main Street Ashland. MA 01721 F -93- 1120.1 Rev AB © 2007 Kidde - Fenwal Inc Printed in USA I'5 508881 2000 Fee. 508 881 8920 www (enwultire corn • Effective: July 2009 Initiator , � °'FE AL for Spherical Agent Storage Containers \ P/N 93- 002009 -004 - Protection Systems A UTC Fire & Security Company F - 93 - 1934 FEATURES • 4 Pin Threaded Connector • Supplied with shorting device for safe and easy handling DESCRIPTION ,d The initiator is a compact releasing device, containing a small explosive charge, which allows the control panel to simultaneously discharge multiple spheres on a single releasing circuit. I Handle and store in accordance with appropriate federal, state, and local regula- WARNING tions governing explosive materials. \\ . J o Never handle, transport, store, or install the o 0 initiator assembly unless the shorting device supplied with the assembly is prop- _ erty installed. Safety glasses or a face yIEW SHOWN WITH A shield must be worn when handling these SHORTING DEVICE REMOVED CAUTION devices. Ensure that the fixture, tools, initi- ator and installer are all grounded to the same point. Improper handling, misuse or MAINTENANCE abuse of this device can cause bodily The initiator assembly shall be stored in accordance with injury. federal, state and local regulations and stored at a 70 -75 °F (21 -24 °C) ambient temperature range. The ser- vice life varies with the maximum temperature to which it is exposed for an appreciable length of time. See Table 1. OPERATION At the end of its service life, the initiator must be removed A 2.0 amp electrical current activates the initiator assem- and destroyed in accordance with local regulations. A bly, which ruptures the sphere's burst disc valve. The ini- four digit date code is stamped on each initiator. The first tiator is destroyed by its operation and must be replaced two digits indicate the year of manufacture. The last two whenever a system is actuated. digits indicate the week (out of 52 weeks). If an initiator is installed in an agent storage container that has relieved INSTALLATION as a result of an over - pressure, both the initiator and well assembly should be replaced regardless of the initiator's The initiator assembly is inserted into a well in the agent age. The initiator must be destroyed in accordance with storage container and connected to the cable assembly local regulations. (29- 126879 -00X) provided with each sphere. Reference the applicable Fenwal design manual for details on the proper installation and testing procedures for this device. SPECIFICATIONS Weight: 1.04 oz. (29.5 g) Length: 3.19 in. (81 mm) • Diameter: 1.125 in. (285 mm) • Bridge Resistance: 1.6 Ohms • • • Series Firing: - ' Maximum of 8 devices • per circuit Base Charge: 200 mg Lead Azide UN /NA Number: UNO255 • • Primary Hazard 1.4B Class /Division: Table 1:. Service Life • Maximum Exposed Temperature Service Life of oC . Years • 80 26 5 100 37 3 • 120 48 2 130 54 1 . • • • • • • • • • • • • • • . - FE This literature is provided for informational purposes only. KIDDE - FENWAL, INC. b assumes no responsibility for the product's suitability for a particular application. The prod- ' . uct must be properly applied to work correctly. . �' Protection Systems If you need more information on this product, or if you have a particular problem or ques- A UTC Fire &Security Company tion, contact KIDDE,- FENWAL; INC., Ashland, MA 01721. Telephone: (508) 881 -2000. . 400 Main Street Ashland, MA 01721 F -93 -1934 Rev AB © 2009 Kldde- Fenwal Inc. Printed in USA Ph: 508 881.2000 Fax 508 881 8920 • Effective: May 2007 Wall Mounting Bracket - FENINAL - P /N: 31- 194019 -001 - Protection Systems A UTC Fire & Security Company F - 93 - 3119.1 DESCRIPTION The Wall Bracket shown is used to mount Fenwal Modu- lar Spherical FM -200TH Agent Storage containers. 9 in INSTALLATION 247.7 mm 111/4 m The bracket may be mounted with in the position shown 282.6mm 1. Sin or inverted. Six bolt holes are provided for secure mount- J 127 mm� ing, using 1/2 in. (12.7 mm) hardware. The bracket also 5 9,, b ;n may be welded to stanchions, beams or bulkheads. The 141.3 mm ti mounting holes bust be laid out to the dimensions shown below to a tolerance of 1/32 in. (.79 mm) on each hole o location. Mount against a rigid structural member or wall. 13 m. We■ght , 251bs 7134 Kg , ...,........> o 0 0 15'/e in 397 mm . Manufactured from 0.250 in. (6.4 mm) stock This literature is provided for informational purposes only. KIDDE - FENWAL, INC. assumes Fenwal Protection Systems no responsibility for the product's suitability for a particular application. The product must be A UTC Fire & Security Company properly applied to work correctly. 400 Main Street If you need more information on this product, or if you have a particular problem or question, Ashland, MA 01721 contact KIDDE - FENWAL, INC., Ashland, MA 01721. Telephone: (508) 881 -2000. Ph: 508.881.2000 F -93- 3119.1 Rev AB © 2007 Kidde - Fenwal Inc. Pnnted in USA Fax: 508.881.8920 www.fenwalfire.com FM -200 COMPONENT DESCRIPTION Effective June 1999 • 180 Degree Pendant Nozzle . F -93 -2150 • FEATURES • FOR USE WITH UL LISTED, ULC LISTED & FMRC APPROVED SYSTEMS METAL STAMP X -XXX (DASH NO.) IN .093 ±.031 HIGH CHARACTERS ON ANY FLAT - • • D A f C . • B • 0 . 60° .12110" =MA 1111111■ Ln „ S `� 30' �P 180 DEGREE NOZZLE Pipe Size A B - C D 1/2" (12.20mm) 1.250" (31.75mm) 1.250" (31.75mm) 1.687 ". (42.84mm) 2.000" (50.80mm) 3/4" (19 05mm) 1.500" (38.10mm) 1.375" (34.92mm) 1.950" (48.89mm) 2.296" (58.31mm) • 1" (25.40mm) 1.750" (44.45mm) 1.562" (39.67mm) 2.218" (56.33mm) 2.671" (67.84mm) 1 -1/4" (31.75mm) 2.250 ". (57.15mm) 1.750" (44.45mm) 2.656" (67.46mm) . 3.250" (82.55mm) 1 -1/2" (38.10mm) 2.250" (63.50mm) 1.950" (48.89mm) 2.950" (74.93mm) 3.625" (92.07mm) • 2" (50.80mm) 3.000" (76.20mm) 1.968" (49.98mm) 2.875" (73.02mm) 3.656" (92.86mm) A SELECTION OF ORIFICES ARE AVAILABLE FOR • EACH NOZZLE SIZE. CONSULT YOUR FENWAL P /N: 93 19401X - XXX DESIGN AND INSTALLATION MANUAL FOR DETAILS • 7. This literature is provided for informational purposes only. KIDDE- FENWAL,INC. assumes " F EF NAL 0 / \i) responsibility for the product's suitability for a particular application. The product must be properly applied to perform as described herein. � If you need more information on this product, or if you have a question, contact KIDDE- 101:10E-FENWAL. . .va uro m FENWAL, INC., Ashland, MA 01721; Telephone (508) 881 -2000 41 (!mi ®1 -1400 FAX (50111diaA • Protocbori systems F -93 -2150 ©1999 Kidde - Fenwal, Inc Printed in U.SA. • .r 1: e b . - 1 Protection Systems SUPPRESSION SYSTEMS INC. 4417 PACIFIC HIGHWAY EAST TACOMA, WA 98424 -2611 NINA REEVES Phone: 253 -926 -3300 FAX: 253- 926 -3306 Exceed -Flow FEN3.03 UL: EX4674 Project: DOW AGRO SERVER ROOM File Name. 1118 SERVER ROOM FLC Consolidated Report Customer Information Company Name: DOW AGRO SCIENCES Address: 16160 SW BOONES FERRY RD TIGARD, OREGON Phone: Contact. Title: Project Data Project Name: DOW AGRO SERVER ROOM Designer: NINA M. REEVES Number: 1118 Account: Location: SERVER ROOM #146 Description: Page: 1 of 6 Calculation Date/Time: Tuesday, June 28, 2011, 10:16:28 AM Copyright (c) Hughes Associates, Inc Licensed to: Kidde - Fenwal FE AL Consolidated Report Protection Systems Enclosure Information Elevation: 0 ft (relative to sea level) Atmospheric Correction Factor: 1 Enclosure Number: 1 Name: SERVER ROOM #146 Enclosure Temperature... Minimum: 70 F Maximum: 70 F Maximum Concentration: 6.302 % Design Concentration... Adjusted: 6.302 % Minimum: 6.250 % Minimum Agent Required: 69.4 lbs Width: 22.0 ft Length: 12.0 ft Height: 8.7 ft Volume: 2296.8 cubic ft Non - permeable: 0.0 cubic ft Total Volume: 2296.8 cubic ft Adjusted Agent Required: 70.0 lbs Number of Nozzles: 1 Page: 2 of 6 Calculation Date/Time: Tuesday, June 28, 2011, 10:16:28 AM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde - Fenwal FENWAL Consolidated Report Protection Systems Agent Information Agent: FM -200 / Propellant N2 (FM -200 is a Trademark of Great Lakes Chemical Corp.) Adjusted Agent Required: 70.0 lbs Container Name: 70 lb Cylinder Container Part Number: 93- 100070 -001 Number of Main Containers: 1 Number of Reserve Containers: 0 Manifold: No Manifold Pipe Take Off Direction: Horizontal Agent Per Container: 70.0 lbs Fill Density: 70.0 lbs / cubic ft Container Empty Weight: 52.0 lbs Weight, All Containers + Agent: 122.0 lbs Floor Area Per Container: 0.44 square ft Floor Loading Per Container: 277 lbs / square ft Pipe Network Part 1 - Pipe Pipe Description Start End Type Diameter Length Elevation Main Cyl. X 1 0 1 1 -1/2 in 2.99 ft 2.99 ft Adapter 1 2 1 -1/2 in 0.22 ft 0.00 ft Pipe 2 3 40T 1 in 0.50 ft 0.00 ft Pipe 3 4 40T 1 in 5.83 ft 5.83 ft Pipe 4 5 40T 1 in 3.00 ft 0.00 ft Pipe /E1 -N1 5 6 40T 1 in 0.50 ft -0.50 ft Part 2 - Equivalent Length Start End 90 45 Thru Side Union Other Added Total 0 1 0 0 0 0 0 0.00 ft 50.0 ft 1 2 0 0 0 0 0 1 -1 /2in VOA 0.00 ft 11.8 ft Page: 3 of 6 Calculation Date/Time: Tuesday, June 28, 2011, 10:16:28 AM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde- Fenwal 1 ral ! . FE AL- Consolidated Report Protection Systems Part 2 - Equivalent Length Start End 90 45 Thru Side Union Other Added Total 2 3 0 0 0 0 0 0.00 ft 0.5ft 1 3 4 1 0 0 0 0 0.00ft 8.6 ft 4 5 1 0 0 0 0 0.00 ft 5.8ft 5 6 1 0 0 0 0 0.00 ft 3.3 ft Part 3 - Nozzles Start End Flow Name Size Type Nozzle Area 0 1 70.0 lbs 1 2 70.0 lbs 2 3 70.0 lbs 3 4 70.0 lbs 4 5 70 0 lbs 5 6 70.0 lbs E1 -N1 1 in 180° 0.3623 square in Parts Information Total Agent Required: 70.0 lbs Container Name: 70 lb Cylinder (Part: 93- 100070 -001) Number Of Containers 1 Nozzle Type Nozzle Area Part Number E1 -N1 180° 0.3623 square in 93- 194015 -238 Pipe: Type Diameter Length 40T 1 in 9.83 ft 'Other' Items: 1 - 1 -1/2 in. Valve Outlet Adapter (Part: 283904) List of 90 degree elbows: 3 - 1 in . System Acceptance Page. 4 of 6 _ Calculation Date/Time: Tuesday, June 28, 2011, 10:16:28 AM Copyright (c) Hughes Associates, Inc Licensed to. Kidde - Fenwal FENWAL Consolidated Report Protection Systems System Discharge Time: 9 8 seconds Percent Agent In Pipe: 11.6% Percent Agent Before First Tee: 0.0% Enclosure Number: 1 Enclosure Name: SERVER ROOM #146 Minimum Design Concentration: 6.250% Adjusted Design Concentration: 6.302% Predicted Concentration 6.302% Maximum Expected Agent Concentration: 6.302% (At 70 F) Minimum Adjusted Predicted Nozzle Agent Agent Agent Pressure Nozzle Required Required Delivered (Average) E1 -N1 69.4 lbs 70.0 lbs 70.0 lbs 135 psig Standard Isometric View 4 • =Aran VOA 1 X70 lb (y1inder-.No Manifold - 1 - /V ` S Page: 5 of 6 Calculation Date/Time: Tuesday, June 28, 2011, 10:16:28 AM Copyright (c) Hughes Associates. Inc Licensed to: Kidde - Fenwal 3 Consolidated Report Protection Systems Standard PhnqV�w � � | | w | s | X 7 mc�nmy No Manifold �� ��� - . | | � | ' -'-- ---- � S����mwdE�m�m�m� --''- --'--�-'- - ' / _-- - _ . ! | i | � � ! ' w / s | � /��wo�nmy'wow^*mm 70 / ! Page: 6 of 6 Calculation Date/Time: Tuesday June 28, 2011, 10:16:28 AM Copyright (C) Hughes Associates. Inc. Licensed to: Kidde-Fenwal t1, FENWAL Protection Systems SUPPRESSION SYSTEMS INC. 4417 PACIFIC HIGHWAY EAST TACOMA, WA 98424 -2611 NINA REEVES Phone: 253- 926 -3300 FAX: 253- 926 -3306 Exceed -Flow FEN3.03 UL: EX4674 Project: DOW AGRO LAN ROOM File Name: 1118 LAN ROOM.FLC Consolidated Report Customer Information Company Name: DOW AGRO SCIENCES Address: 16160 SW BOONES FERRY RD TIGARD, OREGON Phone: Contact: Title: Project Data Project Name: DOW AGRO LAN ROOM Designer: NINA M. REEVES Number: 1118 Account: Location: LAN ROOM #123 Description: Page: 1 of 6 Calculation Date/Time: Tuesday, June 28, 2011, 2:25:43 PM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde - Fenwal � FE Consolidated Report Protection Systems Enclosure Information Elevation: 0 ft (relative to sea level) Atmospheric Correction Factor: 1 Enclosure Number: 1 Name. LAN ROOM #123 Enclosure Temperature... Minimum: 70 F Maximum: 70 F Maximum Concentration: 8.034 Design Concentration... Adjusted: 8.034 % Minimum: 6.250 % Minimum Agent Required: 20.7 lbs Width: 9.8 ft Length: 8.0 ft Height: 8.7 ft Volume: 682.1 cubic ft Non - permeable: 0.0 cubic ft Total Volume: 682.1 cubic ft Adjusted Agent Required: 27.0 lbs Number of Nozzles: 1 Page: 2 of 6 Calculation Date/Time: Tuesday, June 28, 2011, 2:25:43 PM Copyright (c) Hughes Associates, Inc. Licensed to Kidde - Fenwal FENWAL Consolidated Report Protection Systems Agent Information Agent: FM -200 / Propellant N2 (FM -200 is a Trademark of Great Lakes Chemical Corp.) Adjusted Agent Required: 27.0 lbs Container Name: 44 lb. Sphere Container Part Number: 93- 110201 -001 Number of Main Containers: 1 Number of Reserve Containers: 0 Manifold: No Manifold Pipe Take Off Direction: Down Agent Per Container: 27.0 lbs Fill Density: 41.2 lbs / cubic ft Container Empty Weight: 28.5 lbs Weight, All Containers + Agent: 55.5 lbs Floor Area Per Container: 0.91 square ft Floor Loading Per Container: 61 lbs / square ft Pipe Network Part 1 - Pipe Pipe Description Start End Type Diameter Length Elevation Main Cyl.X1 0 1 1 -112 in 0.50ft -0.50ft Pipe /E1 -N1 1 2 40T 3/4 in 1.00 ft -1.00 ft Part 2 - Equivalent Length Start End 90 45 Thru Side Union Other Added Total 0 1 0 0 0 0 0 0.00 ft 15.0 ft 1 2 0 0 0 0 0 0.00 ft 1.0 ft Part 3 - Nozzles Start End Flow Name Size Type Nozzle Area 0 1 27.0 lbs • 1 2 27.0 lbs El - N1 3/4 in 180° 0.1605 square in Page: 3 of 6 Calculation Date/Time: Tuesday, June 28, 2011, 2:25:43 PM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde - Fenwal FENWAL Consolidated Report Protection Systems Parts Information Total Agent Required 27.0 lbs Container Name: 44 lb. Sphere (Part: 93- 110201 -001) Number Of Containers: 1 Nozzle Type Nozzle Area Part Number E1 -N1 180° 0.1605 square in 93- 194014 -156 Pipe Type Diameter Length 40T 3/4 in 1.00 ft Text System Acceptance System Discharge Time: 6.2 seconds Percent Agent In Pipe: 3.5% Percent Agent Before First Tee: 0.0% Enclosure Number: 1 Enclosure Name: LAN ROOM #123 Minimum Design Concentration: 6.250% Adjusted Design Concentration: 8.034% Predicted Concentration: 8.034% Maximum Expected Agent Concentration: 8.034% (At 70 F) Minimum Adjusted Predicted Nozzle Agent Agent Agent Pressure Nozzle Required Required Delivered (Average) E1 -N1 20.7 lbs 27.0 lbs 27.0 lbs 226 psig Page: 4 of 6 Calculation Date/Time: Tuesday, June 28, 2011, 2:25:43 PM Copyright (c) Hughes Associates, Inc. Licensed to. Kidde - Fenwal FENWAL Consolidated Report Protection Systems Standard Isometric View 1X44 lb Sphere, kignifold El-NI (A / Standard Plan View 1X .4 lb Sphere - No Manifold E Page: 5 of 6 Calculation Date/Time: Tuesday, June 28, 2011, 2:25:43 PM Copyright (c) Hughes Associates, Inc. Licensed to: Kidde-Fenwal FENVVAL Consolidated Report Protection Systems Standard Elevation View 1 X 44 lb Sphere - No Manifold E El-N1 Page: 6 of 6 Calculation Date/Time: Tuesday, June 28, 2011, 2:25:43 PM Copyright (c) Hughes Associates, Inc. Licensed to. Kidde-Fenwal [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]