Loading...
Plans[Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] RECEIVED F p 201--col 33 R I S 3 50 5 v Se rn � 15 2011 32c CITY OFTIGARD BUILDIN DIVISIO • �� S1 YSTEM SENSOR' Selectable Output ` ' y Horns, Strobes, and Horn /Strobes SpectrAlert' Advance selectable - output horns, strobes, and horn /strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTRitilert o s E Features The SpectrAlert Advance series of notification appliances is • Electrically compatible with existing SpectrAlert products designed to simplify installations, with features such as plug in Automatic selection of 12 or 24 -volt operation at 15 and 15/75 designs, instant feedback messages to ensure correct installation of • candela individual devices, and 11 field - selectable candela settings for wall and ceiling strobes and horn /strobes. • Plug -in design • Field selectable candela settings on wall and ceiling units: 15,15/75, When installing Advance products, first attach a universal mounting 30, 75, 95, 110, 115, 135, 150, 177,185 plate to a four -inch square, four -inch octagon or double -gang • Same mounting plate for wall- and ceiling -mount units junction box.The two-wire mounting plate attaches to a single -gang • Shorting spring on mounting plate for continuity check before junction box. installation Next, connect the notification appliance circuit wiring to the SEMS • Tamper resistant construction terminals on the mounting plate, • Outdoor wall and ceiling products rated from -40'F to 151°F • Design allows minimal intrusion into the back box Finally, attach the horn, strobe or horn /strobe to the mounting plate Horn rated at 88+ dbA at 16 volts by inserting the product's tabs in the mounting plate's grooves. The • device will rotate into position, locking the product's pins into the • Rotary switch for horn tone and three wlume selections mounting plate's terminals.The device will temporarily hold in place • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) with a catch until it is secured with a captured mounting screw. outdoor requirements • Outdoor products NEMA 4X rated The SpectrAlert Advance series includes outdoor notification Compatible with MDL sync module appliances. Outdoor strobes and horn /strobes (two wire and four • wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit In wet or Agency Listings dry applications. '1/ " 71751653 18e(nOw ivcoril MEik 1 7)pp 166) 87(alrpav fv°MV (04 7175165) 168 chvNy .% (�� A��p I�1 7t1Stf6)1l9 man.c7.meU a • 54011 397.1572 1.15.1457-051 55S12 53593 SpectrAlert Advance Specifications Architect /Engineer Specifications General 1' SpectrAiert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 134-inch back box, 4 inch octagon back box or double gang back box Two -wire products shall also mount to a single -gang 2 x 4 x 1 back box A universal mounting plate shall be used for mounting ceiling arx1 wall products The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit' Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate cn a nominal 12 Of 24 volts When used with the Sync-Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 175 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field- selectable candela settings including 15,15/75, 30. 75,95, 110, 115, 135, 150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at I Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system Horn /Strobe Combination The horn /strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary- signaling notification appliance and comply With the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and assooated lens/reflector system The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non - temporal (continuous) pattern These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between ntinus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof bade box with half inch and three-four the inch conduit entries Synchronization Module The module shall be a System Sensor Syncttcuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn /strobe models over a single pair of wires The module shall mount to a Orr /b x 41/4 x 21/4-ich back box The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit The module shall synchronize multiple zones Daisy chairing two or more synchronization nodules together wit synchronize all the zones they control. The module shall not operate on a coded power supply. Physical /Electrical Specifications Standard Operating Temperature 32•E to 1201 (0 to 49'C) K Series Operating Temperature -40°F to 151 ( -40 to 66 Humidity Range 10 to 93% non - condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWRox regulated 24DC/F1ArR' Operating Voltage Range' 8 to 175 V (12V nominal) a 16 to 33 V Q'4 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8 x 2.5 high (173 nrrn diameter x 64 mm high) Wall mount dimensions (including lens) 561 x 47W x 75131(142 mrn L x 119 mm W x 64 mm D) Horn dimensions 5.61. x4.7Wx 1.31)(142 mm Lx 119rnmWx33trmD) Wall -mount back box skirt dimensions (BBS-2, BBSW -2) 5.91 x SOW x 2.21) (151 mm L x 128 mm W x 56 mm D) Ceiling - mount back box skirt dimensions (BBSC - 2, BBSCW - 2) 7.1 diameter x 2.25' high (18O non diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA -WBB) 5.71 x 5.1'W x 2.01)(145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (5A -WBBC) 7.1' diameter x 2.0" high (180 mm diameter x 51 mm high) Wall -mount trim ring dimensions (TR -HS, TRW -HS) 5.71 x 4817W x 0350 (146 mm L x 122 W mm x 9 D mm) Ceiling - mount trim ring dimensions (TRC -HS, TRCW -HS) 6.9 " diameter x 0.35 high (176 trim diameter x 9 mm high) Notes: 1. Full Wave Rectified (F W11) voltage is a non - regulated, time varying power source that is used on some power supply and panel outputs 2. P,, S, PC, and SC products will operate at 12 V nominal only fa 15 and 15/75 cd xecnr�r� f UL Currant Draw Data UL Max. Strobe Current Draw (mA RMS) Ul Max. Horn Current Draw ImA RMS) 8 -17.5 Volts 16-33 Volts 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC F WR Standard 15' 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15115 142 148 77 81 Temporal Medium 44 49 58 69 30' NA NA 94 96 Temporal low 38 44 44 48 75' NA NA 158 153 Non - temporal High 57 56 69 75 95' NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 - wire Hom/Strobe, Standard Candela Range (15 - 115 col) 8 -17.5 Volts 16 -33 Volts DClnput 15 15/75 15 15 /75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - temporal High 141 157 91 100 116 176 201 221 229 Non - temporal Medium 133 145 75 85 102 163 187 707 216 Na i-terrlporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Median 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non - temporal Medium 134 155 85 95 110 166 189 208 216 Non- temporal Low 132 154 80 90 105 161 184 202 211 . UL Max. Current Draw (mA RMS), 2 -wire Hom /Strobe, High Candela Range (135 -185 cd) 16-33 Volts 16 - Volts DClnput 135 150 177 185 FWR input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-terrporalHigh 255 270 303 309 Non - temporal High 233 248 275 281 Non - temporal Medium 242 259 293 299 Non- temporal Medium 219 232 262 267 Non - temporal Low 238 254 291 295 Non - temporal Low 214 229 256 262 Candela Doratinp Horn Tongs and Sound Output Data For K series products used at low temperatures, listed candela Horn and Horn Strobe OutputidBAI ratings must be reduced in accordance with this table. 24 Volt Nominal Strobe Output (cdl 8 17.5 Switch Volts Volts Vohs Reverberant Anechok Listed Candela Candela rating at -40*F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32'F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non-temporal High 82 82 88 88 93 92 100 100 95 70 5 Non-temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non-temporal low 75 75 81 81 88 84 96 92 115 115 7' Coded High 82 82 88 88 93 92 101 101 135 135 8 Coded Medium 78 78 85 85 90 90 97 98 150 150 9' Coded Low 75 75 81 81 88 85 96 92 177 177 'Settings 7, 8, and 9 are not available on 2 -wire horn/strobe 185 185 ACISmrsaos 1 SpectrAlert Advance Dimensions , ..r :s' Q e• o+ 11. 1 lb _ f � � Wall -mount horn/strobes Ceiling -mo unt horn/strobes r.s 7 1' . 751 0 a 5.06 -• 2.23 1 1 — - - -. s.sb II 7 op000\ . . , ' ' - -7 `10 . lo. P 4 o et.r e 0 e e ® i o s t � Q � � po e0 1 \ p O ' \\ ` 0 -` Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model Description Model Description Wall Hom/Strobes Ceiling Hom /Strobes (cont'd.) P2R" 2 -wire Han/Strobe, Standard cd', Red PC4W 4 -wke Han/Strobe, Standard cd, White P2RH' 2 -wire Horn/ Strobe, High cd. Red PC4WH 4-wire Hom/Strobe, High cd Wile P2FK'° 2 -wire Han/Strobe, Standard cd Red, Outdoor Ceiling Strobes P2R'IK° 2 -wire Horn/Strobe, High cd, Red, Outdoor SCR' Strobe, Standard cd Red P2W 2 -wire Horn/Strobe, Standard cd White 5014' Strobe. High cd Red P2WH' 2 -wire Horn/Strobe, High al, White SCRIP Strobe, Standard cd Red, Outdoor P4R' 4 -wire Han/Strobe, Standard cd Red SCM' Strobe, High cd Red, Outdoor - P4F1H' 4-wIre HorrVSirobe, High cd, Red SCW" Strobe, Standard cd, White P4R C' 4-wire Horn/Strobe, Standard cd Red Outdoes SCWH" Strobe. High cd White P4RHHK' 4 -wire Horn/Strobe, High cd, Red, Outdoor Horns P4W• 4-wire Horn/Strobe, Standard cd White HR Horn, Red P4WH' 4-wire Horn/Strobe, High cd, White HPo(° Han, Red, Outdoor Wall Strobes HW Han, White SR" Strobe, Standard cd, Red Accessories SRH" Strobe, High cd Red BBS-2 Back Box Skirt, Wall, Red SR P Strobe, Standard cd, Fed, Outdoor BBSW -2 Back Box Skirt, Wall, White SRHK Strobe, High cd Red, Outdoor BBSC -2 Back Box Skirt, Wing, Red j SW' Strobe, Standard cd, White BBSCW -2 Bads Box Skirt, Ceiling, White SWH' Strobe, High cd, White TR-HS Trim Reg, Wall, Red Ceiling Hom/Strobes TRW-HS Trim Ring, Wail White PC2R• 2 -wire Horn/Strobe, Standard cd, Red T1* -HS Trim Rig, Ceiling, Red PC2RH' 2 -wire Horn/Strobe, High cd, Red TRCW -HS Trim Fling, Ceiling, White + PC2FIC 2 -wire Han/Strobe, Standard cd Red, Outdoor Notes PC2RHil(' 2 -wire Horn/Strobe, High cd. Red, Outdoor • Add' -P' to model number for plain housing (no 'FIRE'marking on coved. eg, PC2W" 2 -wire Horn/Strobe, Standard cd, White P2R-P. F'C2WM" 2-wire Horn/Strobe, High <d, Write t Add"-SP" to model number for 'FuEGO'marWng on cover, e.g, P2R-SP Red 4'Standard cd; refers to strobes that l dole 15,15/75,30, 75,95,110, and 115 PC4R 4-wire Horn/Strobe, Standard cd, candela settingt'High cc refers to strobes that Include 135,150,177, and 185 PC4RH 4 -wire Horn/Strobe, High cd, Red candela settings PC4RK 4-wire Horn/Strobe, Standard cd Red. Outdoor Al outdoor units ending In IC include a weatherproof back box PC4IU(' 4 -wire Horn/Strobe, High cd, Red Outdoor o Add' -R` to model number for weatherproof replacement device (no back bat Included). ,, ,..„ =1 3825 Ohio Avenue .St. Charles, IL 60174 noesewecewmmu /ea +a«ca Phone 800- SENSOR2 • Fax 630. 377. 6495 anent po°""1pA "hest" °°"p°"'"""""° °o1stnaO c ■ A05 395905•MI•ROt. i 1535 5•A/ Pkwy 32b p5 zot ► -o0 133 RECEIVED - Global Project Values: 1 it i4 SILENT Project Name:IPACTRUST - 15350 SEQUOIAPI< Standby Hours 1 24 NOV 1 5 2011 KNIGH'I' Project ID:IPROFESSIONAL EYE Alarm Mins :1 5 Prepared By:1Gary Tauscher I Derating Factor 1 2 CITYOFTIGARD 5495 Power Expander Calculations Date:111 /9/2011 I Voltage Drop Warning BUILDING DIVISION Version 02.18.09 Threshold %: 1 10 1 Panel ID: 15495 I Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location: 115350 SW SEQUOIA 2ND FL0 Volts: 24 VDC Max Panel Current: 6.0 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Circuit Name Standby Alarm & Type 1000 Ft. One -Way Ohms EOL /oDrop 5495 5495 Pwr Module 1 1 0.075 1 0.205 _ NAC #1 5495 Circuit 1 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% NAC #2 5495 Circuit 2 0.000 0.000 #12 Solid 1.59 0 0.00 20.40 0.00% NAC #3 5495 Circuit 3 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0.00% NAC #4 5495 Circuit 4 0.000 0.878 #14 Solid 2.52 245 1.23 19.32 5.31% Aux 5495 Aux Power Out 0.000 0.000 #14 Solid 2.52 _ 0 0.00 20.40 0.00% Total Standby Current (Amps) 0.075 1.083 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 _ 0.090 Total Alarm AH Required Total Combined AH Required 1.89 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.27 1 C onfigure Circuits Print Page . ' . MI I_IN'I' ;:NI Circuit Configuration r Project Information Project Name: PACTRUST - 15350 SEQUOIAPKW #300 Project ID: PROFESSIONAL EY E Prepared By: Gary Tauscher Date: 11/9/2011 Ckt. Number: NAC #1 Panel ID: 5495 Ckt. Name: 5495 Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm System Sensor P2 /PC2 Horn /Strobe (115cd) 0.000 0.229 0.000 0.000 System Sensor S /SC Strobe (115cd) 0.000 0.210 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: NAC #2 Panel ID: 5495 Ckt. Name: 5495 Circuit 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm System Sensor P2 /PC2 Horn /Strobe (115cd) 0.000 0.229 0.000 0.000 System Sensor S /SC Strobe (115cd) 0.000 0.210 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: NAC #3 Panel ID: 5495 Ckt. Name: 5495 Circuit 3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm System Sensor P2 /PC2 Horn /Strobe (115cd) 0.000 0.229 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: NAC #4 Panel ID: 5495 Ckt. Name: 5495 Circuit 4 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total _ Standby _ Alarm Standby Alarm 2 System Sensor S /SC Strobe (115cd) 0.000 0.210 0.000 0.420 2 System Sensor P2 /PC2 Horn /Strobe (115cd) 0.000 0.229 0.000 0.458 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.878 Ckt. Number: Aux Panel ID: 5495 Ckt. Name: 5495 Aux Power Out Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm ' SpectraAlert P2475 Horn /Strobe 0.000 0.148 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000