Plans[Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] I (� 9 o s dov FRS 20 l O oO IS L i RECE Advanced Security & Fire QE D 2218 NE Sunrise Lane, Hillsboro OR 97124 D c 9 ?010 (503) 519 -4550 Fax (503) 357 -8157 CITY BuILD INGD A p December 7, 2010 N Fire Alarm Operational Matrix General Overview The fire alarm system will have battery back up to sustain it in the case of an AC power failure. Alarm system will have dual phone lines, a primary and secondary, if the primary fails the secondary will transmit signals to central station. All functions of the fire alarm system are supervised, (AC power, low battery, phone line integrity, and all alarm circuits. ) Fire alarm troubles and alarms are both transmitted to the central station and annunciated locally at the keypad. Specific Operation • Troubles are annunciated at panel, at the same time they are transmitted to the central station. Operator at central station will call a predetermined response list to notify of trouble. Advanced Security & Fire will be notified of system troubles at the same time. • Alarms will be transmitted to the central station as well as annunciated locally. Central station will notify 911 of fire alarm, and then call premises to try and verify alarm. Response list will be called to notify users of alarm. • Alarms can be silenced at the fire alarm panel by pressing fire silence button. • Fire system will be in trouble until fire alarm system is reset by pressing the fire reset button. • Equipment room smoke detector monitors for smoke in equipment room, and sprinkler water flow monitors for water flow in fire sprinkler system, both will trigger a fire alarm. • Upon trigger of fire alarm by smoke detector, sprinkler water flow, or manual fire pull station alarm will be annunciated locally via outside bell and central station will be signaled Company Information Advanced Security & Fire is located in Hillsboro, Oregon and is owned and operated by David Moravik. I have been in the alarm industry since 1981 and licensed as a journeyman low voltage electrician since 1984, ( license # 611LEA ). My state of Oregon electrical license is ( CLE -8 ). Advanced Security & Fire is registered with the state of Oregon contractor's board (contractor's board # 166176). We are a member of the NFPA, and the local fire and burglary alarm association. Central Station Information Advanced Security & Fire monitors its alarm systems through Central Station Monitoring in Estacada, Oregon. They are certified to monitor all alarm system types. Phone # is ( 503- 630 -2896 ). Sincerely, Advanced Security & Fire FIRE SYSTEM ACCESSORY . F 35 Zo10 rc=amI5 It li SILENT 5496 Intelligent KNIGHT Power Module by Honeywell A dynamic combination of power and intelligence for your notification expansion needs. The Model 5496 Intelligent Power Module by Silent Knight is the most - powerful and cost - effective power supply available today. It delivers 6 amps of notification appliance circuit power and built -in synchronization for appliances from System Sensor°, Gentex®, Faraday, AMSECO and Wheelock® — what you need to drive power -hungry components like ADA notification appliances. The 5496's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. For the most sophisticated and cost - effective notification power supply available, you need Model 5496. Call Silent Knight today for more information at 1- 800 - 328 -0103. Model 5496 • 3 amps per output circuit Intelligent Power Module • Ground fault detector The model 5496 is a 6 amp notification • Communicates to the FACP via 4- power expander that provides its own wire SBUS (wire runs up to 6000 ft) AC power connection, battery charging • AC loss delay option shuts off power circuit, and backup battery for use with Y to non-essential high current fire and security controls such as the accessories like magnetic door IntelliKnight Model 5808 Fire Control holders /Communicator. The 5496 is the cost- • Lightweight design adds to ease of effective solution for powering installation and reduces shipping notification appliances required by the pp g costs _ Americans with Disabilities Act (ADA). • UL 864,1481 & 1971 listed - The 5496 has built -in ANSI cadence ANSI Cadence pattern output pattern, which can upgrade older L ' control panels that lack cadence capability built in : F capability. The Output circuits can be Specifications .^ programmed as Notification Appliance AC Input 120 VAC at 2.7A rlii K M; Circuits, or as Auxiliary Power (configurable for, constant, resettable, Output: 24 VDC at 6 amps or door holder power). Current: Model 5496 Intelligent Features Standby 40 mA Power Module • UL Listed for 6 amps of notification Alarm 160 mA power Ambient Temp.: 32° to 120° F Notification /Aux. 0° to 49° C • Power supply's advanced switch Power circuits: 4 mode design reduces damaging Dimensions: 12.25" W x 16" H x heat and manages power up to 50 Output 3" D (30.88 cm W % configuration: 2 Class A (Style Z) x 40.64 cm H x more efficiently than other systems 4 Class B (Style Y) 7.62 D cm) • Built -in synchronization for (1 Class A & appliances from AMSECO, Gentex<`, 2 Class B) Approvals: UL Faraday, System Sensor4' >, and Amps per CSFM Wheelock output circuit: 3.0 (6.0 amps total) MEA 429 -92 -E vol. XIV • 24 VDC filtered output voltage Notification • Four power - limited notification circuit output: 20.4 to 27.3 VDC Compatible FACPs • outputs; 2 Class A or 4 Class B, or 1 @ 3.0 amps each, • Class A and 2 Class B 4.7k EOL resistor IntelliKnight 5700 • NACs are programmable as required on each • IntelliKnight 5808 . Notification Appliance Circuits, or as Class B circuit IntelliKnight 5820XL auxiliary power to be used as Battery charging constant, resettable, or door holder capacity: 35.0 AH power FIRE SYSTEM ACCESSORY Firepower 5496 Distributed Power Module Engineering Specifications The contractor shall supply a power module compatible with the Silent Knight FACP. The power module must have 6.0 amps of output power. The power module shall connect to the main FACP via an RS 485 system bus (SBUS). The Outputs shall be programmable as Notification Appliance Circuits, or as Auxiliary Power (configurable for, constant, resettable, or door holder power). The power module shall have four separate outputs. The power module RS 485 bus shall be optically isolated providing ground loop isolation and transient protection. 4 Outputs Programmable as Notification Appliance Circuits, or as Auxiliary Power Output 1 . SBUS Communication To a Compatible Output 2 'ill Silent Knight FACP Output 3. Output 4 . Auxiliary Power Can Be Programmed To Be Constant, Resettable, or Door Holder Power SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA KNIGHT to keep our product information up- to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350387 Rev D subject to change without notice. For more information, contact © 2010 Honeywell International Inc. • by Honeywell Silent Knight 12 Clintonville Road, Northford, CT 06472 -1610 Phone: (800) 328 -0103, Fax: (203) 484 -7118. www.silentknight.com - Global Project Values: S I LENT Project Name: [Dow AgroSciences Standby Hours: 24 I TS KNIGHT Project ID:1 Alarm Mins: 5 Prepared By: [Advanced Security & Fire I Derating Factor: 1.2 5496 Power Expander Calculations Date: [ 12/6/2010 Voltage Drop Warning Threshold % : 10 1 Panel ID: 15496(1) I Model: Silent Knight 5496 Power Expander Max Circuit Current: 3 Amps Location: [Electrical Room I Volts: 24 VDC Max Panel Current: 6 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Circuit Name /oDrop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 1 5496(1) Circuit 1 0.000 1.052 #14 Solid 2.52 299 1.51 18.81 7.77% 2 5496(1) Circuit 2 0.000 1.233 #14 Solid 2.52 328 1.65 18.36 9.99% 3 5496(1) Circuit 3 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 4 5496(1) Circuit 4 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Aux 5496(1) Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Aux Power *1 # of NAC's Used I 0.000 0.000 5496 5496 Power Expander 0.040 0.160 2.285 (Amps) Total Output Power Required Total Standby Current (Amps) 0.040 2.445 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required, 0.960 0.204 Total Alarm AH Required • Total Combined AH Required 1.16 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 1.40 *1. A vallue must be entered if you havve selected any output as Aux. Power. Panel ID: [5496(2) Model: Silent Knight 5496 Power Expander Max Circuit Current: 3 Amps Location: I Volts: 24 VDC Max Panel Current: 6 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o Ckt.# Circuit Name /oDrop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 1 5496(2) Circuit 1 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 2 5496(2) Circuit 2 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 3 5496(2) Circuit 3 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 4 5496(2) Circuit 4 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Aux 5496(2) Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% Aux Power *1 # of NAC's Used 0.000 0.000 5496 5496 Power Expander 0.040 0.160 0.000 (Amps) Total Output Power Required Total Standby Current (Amps) 0.040 0.160 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 0.960 0.013 Total Alarm AH Required Total Combined AH Required 0.97 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 1.17 *1. A vallue must be entered if you havve selected any output as Aux. Power. 4 e El ti I I i N I' f�6III.- Circuit Configuration • • Project Information Project Name: Dow AgroSciences Project ID: 0 Prepared By: Advanced Security & Fire Date: 12/6/2010 Ckt. Number: 1 Panel ID: 5496(1) Ckt. Name: 5496(1) Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 Wheelock NS -24MCW 15cd 0.000 0.066 0.000 0.264 2 Wheelock NS -24MCW 30cd 0.000 0.101 0.000 0.202 2 Wheelock NS -24MCW 75cd 0.000 0.177 0.000 0.354 1 Wheelock NS -24MCW 110cd 0.000 0.232 0.000 0.232 0.000 0.000 Totals 0.000 1.052 ii Ckt. Number: 2 Panel ID: 5496(1) Ckt. Name: 5496(1) Circuit 2 Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 Wheelock NS -24MCW 15cd 0.000 0.066 0.000 0.066 4 Wheelock NS -24MCW 30cd 0.000 0.101 0.000 0.404 3 Wheelock NS -24MCW 75cd 0.000 0.177 0.000 0.531 1 Wheelock NS -24MCW 110cd 0.000 0.232 0.000 0.232 • 0.000 0.000 Totals 0.000 1.233 Ckt. Number: 3 Panel ID: 5496(1) Ckt. Name: 5496(1) Circuit 3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 Ckt. Number: 4 Panel ID: 5496(1) Ckt. Name: 5496(1) Circuit 4 Max Circuit Current 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 COOPER Notification Series NS Horn Strobes and Series NH Horns F � ', r Series NS Series NH Description: Features: The Series NS Horn Strobe Appliances are designed for indoor, • Approvals include: UL Standard 1971, UL Standard 464, wall and ceiling mount applications. New York City (MEA), California State Fire Marshal (CSFM), The Series NH Horn and the horn portion of the Series NS include Factory Mutual (FM) and Chicago (BFP). See approvals by a selectable continuous horn tone or temporal pattern (Code 3) with model number in Specifications and Ordering Information selectable dBA settings of 90 or 95 dBA. • ADA/NFPA /UFC /ANSI compliant Strobe options include 1575cd or the Wheelock patented • Complies with OSHA29, Part 1910.165 Multi - Candela strobe with field selectable candela settings of Wall mount model Field Selectable Candela Setting • 15/30/75/110cd for wall mount and 15/30/75/95cd and 115/177cd 15/30/75/110cd (24 VDC Multi Candela models) or 1575cd in for ceiling mount. 12 or 24 VDC These versatile Horn Strobe Appliances can be synchronized using Ceiling mount model Field Selectable Candela Setting • the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies 15/30/75/95cd and 115/177cd (24 VDC Multi Candela or other manufacturers panels incorporating the Wheelock Patented models) Sync Protocol. Additionally, the audible may be silenced while maintaining strobe activation. • Selectable Continuous Horn or Temporal (Code 3) All models of the Series NS and NH are designed for maximum • 2 Selectable dBA settings of 90 and 95 dBA in both tones performance, reliability and cost - effectiveness while meeting or • Patented Universal Mounting Plate exceeding the latest requirements of NFPA 72/ANSI 117.1 /UFC and UL Standards 1971 and 464 as well as meeting ADA requirements • 12 and 24 VDC models with UL "Regulated Voltage" using concerning photosensitive epilepsy. filtered DC or unfiltered VRMS input voltage The Wheelock patented 2 -Wire Series NS Horn Strobes and • Wall and Ceiling Mount Series NH Horns offer more features with lower current draw than • Ceiling models with same look as Wheelock round ceiling competitors. strobes and speakers • NH horn is selectable 12 or 24 VDC in 1 appliance • Synchronize using Wheelock Sync Modules or panels with built -in Wheelock Patented Sync Protocol • Fast installation with IN /OUT screw terminals using #12 to #18 AWG wires • M EA A APPROVED i-'.946 151 -92 -E 7125 -0785:142 1 • NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND • SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range ". Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93% (± 2 %). • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range' is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range ". Table 1: Ratings Per UL Standard 1971 Table 2: dBA Ratings for Series NS /NH Horn Input Regulated Reverberant dBA Anechoic dBA Model Voltage Voltage Strobe Candela Description Volume 10ft per UL 464 10 ft VDC Range (CD) 12 24 12 24 VDC /FWR VDC VDC VDC VDC NS -24MCW 24 16.0 - 33.0 15/30/75/110 Continuous High 83 87 89 95 NS- 241575W 24 16.0 - 33.0 15 (75 on Axis) Horn Low 76 81 84 90 NS- 121575W 12 8.0 -17.5 15 (75 on Axis) Code 3 High 79 82 89 95 NS -24MCC 24 16.0 - 33.0 15/30/75/95 Horn Low 72 76 84 90 NS- 24MCCH 24 16.0 - 33.0 115/177 'Table 3: UL Max Currenr Audible Wall Mount Strobe Models Ceiling Mount Strobe Models Series NS /NH NH -12124 NS- 241575W NS -24MCW NS -24MCC NS- 24MCCH 24 VDC .24VDC 15/75cd 15cd 30cd 75cd 110cd 15cd 30cd 75cd 95cd 115cd 177cd High (95) dBA 24VDC 0.044 0.104 0.074 0.107 0.184 0.244 0.082 0.124 0.209 0.275 0.350 0.477 Low (90) dBA 24VDC 0.018 0.096 0.066 0.101 0.177 0.232 0.071 0.114 0.201 0.261 0.306 0.429 Audible Wall Mount * RMS current ratings are per UL average RMS method. UL Series NS /NH max current rating is the maximum RMS current within the listed 12VDC NH - 12/24 Audif8trobe voltage range (16 -33v for 24v units). For strobes the UL max .12V NS - 121575W current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum High (89) dBA 12 VDC 0.021 0.220 listed voltage (33v for 24v units). For unfiltered FWR ratings, Low (84) dBA 12VDC 0.012 0.210 see installation instructions. Wiring Diagrams# NS /NH APPLIANCE NS AND NH APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILENCE +! -I-0 TO NEXT FEATURE SMI FROIll -�_ APPLIAAICF: FL _ 0 TRoCEL PRECEDING❑ I` OR EOLR _ O ,.. FCaEC - _PPLIANCE, SM /DSM, ❑ A A❑ SNAG❑ a PS- 24 -8MC OR FRCP❑ clr °D T . `P UN CO er -- PEI AudibleL SIGNAL NACQ C ,cu tL NS AND NH APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL NOTE: NS /NH must be set on Code 3 horn tone CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE to achieve synchronized temporal (Code 3) tone. I ,,AI :I,N,: MODUII Refer to installation instruction (P83983, P83600 OsrNC -. respectively). 0�_Nc - l For detail using SM or DSM Sync Module refer a * JUT, l to Data Sheet 53000 or Installation Instructions • _ 0- 0 , I P83123 for SM and P83177 for DSM. For MINURI �— wiring information on the power supplies refer to Installation Instructions P84662 for PS- 24 -8MC. F �AUDIBLF A SIGNAL 1 D ':IAfll''I 'V - AUDIBLE P ti « OUTS — 0 ,' 0 0 MI2 AFF IANCE - 0 \ MINUS? RIG MAL CIRCUIT RETURN SPECIFICATION & ORDERING INFORMATION Order Strobe Sync w/ SM, 24 12 Agency Approvals • Model Number Code Candela DSM or �� VDC Mounting Options# PS -24-8MC UL MEA CSFM FM BFP NS- 24MCW -FR 9404 15/30/75/110 X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 24MCW -FW 9405 15/30/75/110 X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 241575W -FR 7806 15 (75 on Axis) X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 241575W -FW 7811 15 (75 on Axis) X X - B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 121575W -FR 7816 15 (75 on Axis) X - X B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 121575W -FW 7818 15 (75 on Axis) X - X B,D,E,F,G,H,J,N,O,R,X X X X X X NH- 12/24 -R 7449 - X X X B,D,E,F,G,H,J,N,O,R,X X X X X X • NH- 12/24 -W 7500 - X X X B,D,E,F,G,H,J,N,O,R,X X X X X X NS- 24MCC -FR 3754 15/30/75/95 X X - E X X X * NS- 24MCC -FW 3753 15/30/75/95 X X - E X • X X NS- 24MCCH -FR 3756 115/177 X X - E X X X ' NS- 24MCCH -FW 3755 115/177 X X - E X X X * NH- 12/24R -R 3752 - X X X D& E X X X NH- 12124R -W 3751 - X X X D& E X X X 'Pending Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. • ARCHITECTS AND ENGINEERS SPECIFICATIONS The audible /visual notification appliances shall be Wheelock Series NS Horn Strobe appliances and Series NH Horn appliances or • approved equals. The Series NS appliances shall meet and be listed for UL Standard 1971(Emergency Devices for the Hearing - Impaired for Indoor Fire Protection Service). The Series NH Horn shall be UL Listed under Standard 464 (Fire Protective Signaling). The horn strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by the Fire Alarm Control Panel (FACP). The audible portion of the appliance shall have a minimum of two (2) field selectable settings for dBA levels (90 and 95 dBA) and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series NS shall be of low current design. Where wall mount, Multi - Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15130175/110 candela. Where ceiling mount, Multi - Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 for 15/30/75/95 candela or 115/177 candela. The selector switch for selecting the candela setting shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with the Wheelock SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built -in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobes shall revert to a non - synchronized flash -rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation. The Series NS Horn Strobes and NH horn shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single - gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. iN WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA S2100 NS /NH 2/08 NJ Location FL Location VA Location 273 Branchport Ave. 7565 Commerce Ct. 2009 North 14th St., Ste. 510 Long Branch, NJ 07740 Sarasota, FL 34243 Arlington, VA 22201 P: 800-631-2148 P: 941-487-2300 P: 877-459-7726 F: 732-222-8707 F: 941-487-2389 F: 703-294-6560 www.coopernotification.com COOPER Cooper Notification is Wheelock' (MEWL) SAFEPATH' WAVES, Rte.. COOPER Notification Stec ♦e