Specifications ti `120 sti/ 7 I01 g,5 Bulletin 136 Rev.M M odel F1FR Reliable° Model F1FR Recessed 5- Q uick Response Sprinklers Model F1FR Sprinker T f: Standard Upright �B 0 20 ;,. Standard Pendent ' ri° = : Conventional ., oil-ti . Vertical Sidewall CITY OF TIGARD P .. Horizontal Sidewall BUILDING DIVISION ' = .: ' , ' - HSW 1 Deflector Model Fl FR Recessed Sprinkler Types r Recessed Pendent Recessed Horizontal Sidewall Upright Pendent - HSW 1 Deflector > Listings & Approvals ,,..,o,:: ' A _ .e,y 1. Listed by Underwriters Laboratories, Inc. (UL) - , 2. Listed by Underwriters' Laboratories of Canada (ULC) • 3 • . Certified by FM Approvals 1 . 4. Loss Prevention Council (LPC, UK) • .! _ 5. NYC BS &A No. 587 -75 -SA f , � cm , 6. Meets MIL- S -901C and MIL -STD 167 -1 %.,-, Y_ ` 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258-93 -E UL Listing Category Vertical Sidewall Conventional Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number - VNIV f,.� 4 �. ... / :: ,.� Z Patents: US Patent No 6,374,920 Applies to l � `� '� - Model Fl FR Vertical Sidewall Sprinklers. Product Description Horizontal Sidewall Recessed Pendent Reliable Models F1FR and F1FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown) I quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. pands, forcing the bubble smaller and smaller as the liquid The Models Fl FR and Fl FR Recessed automatic sprinklers pressure increases. Continued heating forces the liquid to utilize a 3.0 mm frangible glass bulb. These sprinklers have push out against the bulb, causing the glass to shatter, demonstrated response times in laboratory tests which are opening the waterway and allowing the deflector to distrib- five to ten times faster than standard response sprinklers. This ute the discharging water. quick response enables the Model F1FR and Fl FR Recessed sprinklers to apply water to a fire much faster than standard Application sprinklers of the same temperature rating. Quick response sprinklers are used in fixed fire protec- The glass bulb consists of an accurately controlled amount tion systems: Wet, Dry, Deluge or Preaction. Care must be of special fluid hermetically sealed inside a precisely menu- exercised that the orifice size, temperature rating, deflector factured glass capsule. This glass bulb is specially con- style and sprinkler type are in accordance with the latest structed to provide fast thermal response. The balance of published standards of the National Fire Protection Asso- parts are made of brass, copper and beryllium nickel. ciation or the approving Authority Having Jurisdiction. At normal temperatures, the glass bulb contains the fluid Quick response sprinklers are intended for installation as in both the liquid and vapor phases. The vapor phase can specified in NFPA 13. Quick response sprinklers and stan- be seen as a small bubble. As heat is applied, the liquid ex- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 • Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers , • ' Installation Wrench: Model D Sprinkler Wrench Installation Data: I . • Sprinlder Type K Factor Sprinkler Identification Standard- Upright (SSU) and Pendent (SSP) Sprinkler Approval Number (SIN) U S M etr i c Hei Organization Deflectors Marked to Indicate Po sition I SSU SSP ; " (15mm) Standard Orifice with y," NPT (R);) Thread 5.6 80 2.2" (56mm) 1,2,3.4,5,6,7 R3625 R3615 '%," (20mm) Large Orifice with 3 NPT (R 8.0 115 I 2:3" (58mm) 1.2,3,4.7,8 R3622 83612. ' 7 1F' (17mm) Small Orifice with ," NPT (R,) Thread • • 4.2 60 I 2.2" (56mm) 1,2,8 I R3623 R3613 3q" (10mm) Small Orifice with Y," NPT (R') Thread I 2.8 40 2.2" (56mm) 1,2.8 I R3621 .. R3611 10mm Orifice XLH with R38" Thread 4.2 60 56mm 4,6,7 I R3624 83614 Conventional-Install in Upright or Pendent Position 10mm Orifice XLH with R3',; Thread 4.2 60 56mm — R3674 15mm Standard Orifice with y" NPT (R, 2) Thread 5.6 80 56mm 4,6,7 •, • R3675 20mm Large Orifice with 3 4" NPT (R /.)Thread 8.0 115 58mm 4,7 R3672 l. -' 4, `r a) i� = • y:F, , _ , lea' ' ` .: _ •=- • Upright . . . ' Pendent . • Conventional Model 'F1 FR Quick Response Recessed Pendent Sp I Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread IC Factor Sprinkler Approval Sprinkler Identification Orifice Size US I Metric Height Organizations Number (SIN) • y" (15mm) I }Z• NPT (R1/2) 5.6 I 80 2.2" (56mm) _ 1,2.3,4,5,7,8 R3615 %,," (20mm) • 3;" NPT (R 8.0 115 2.3" (58mm) 1,2,3,8 R3612 - ' ' '' /,e" (11mm) • y," NPT (R1/2) ' 4.2 60 2.2" (56mm) 1,2,8 . R3613 . 3q" (10mm) • y" NPT (R' /2) 2.8 40 2.2" (56mm) 1.2,8 R3611 ' 10mm R3a ' ' 4:2 - 60 56mm 4,7 R3614 '- (1) Refer to escutcheon data table for approvals and dimensions.. . F 2 '/A' HOLE NA. F 2 543 OLE IN CEILING m, —_ ■ - (577mmJ r r5 /r6" O6 2 5 /16' OM fSB.imm) +J " (97-») —' CUP - = = L- - ' = = I- R r/7" REOtrt'lR 1 L I I I X r /7. REDUCER ruRN COLLAR 1 — -f UNTQ TIGHT '/ I , AI:.LVSF SPRWINER NRENCH BOSS ' ' I I I 1 / +4�-1 I�, FACE or l Firmc no " - — - , r 1 cnLLNC Firm UH CEILING �jl•t e , • OO Viz I OF FITNN III�I , 'MT" ,I 1 r0 FACE FACF OF CflLWD ((` -,- - E I L.\- ! DIMENSION,,) r/B (II •A. (11 7 77/37" DU ADJUSTMENT 4 I77.7.mmJ IJ6FG71_F I I • J6FGOSJ • (I) REFER TO PI R F7 ESCUTCHEON•CAA TABLE FOR APPROVALS AND puENSIONS (I) REFER TO FR ESCUTCHEON DA7A G_°LE FOR APPROVALS AND Of4rENSIGNS. . 2. - Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent ' Approval Type: Light Hazard Occupancy Installation Data: Nominal Thread K Factor Sprinkler Approval Sprinkler Height Organizations Number Orifice Size er (SIN US � Metric g g Number (SIN) /" NPT (R' /) 5.6 80 2.2" (56mm) I 1, 2, 3, 6.8 R3685 15mm '/" NPT (R' /) 5.6 80 2.2" (56mm) I 4 t (1) LPC Approval is for Pendent position only. - Orientation Deflector to Ceiling 1 Dimension (Min. - Max.) _A Upright I 4" - 12" (102mm - 305mm) i n i Pendent 6" - 12" (152mm - 305mm) tt . Vertical Sidewall US Patent No. 6,374,920 Model Fl FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: I Approval Organizations K Factor and Type of Approval Sprinkler Identification Nominal Thread Sprinkler Light Ordinary Number (SIN) Orifice Size US Metric Length Hazard Hazard • y" (15mm) z" NPT(R' /) 5.6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and ME.A Listing permits use with Fl or F2 recessed escutcheon. 7 36rG04 % / // j1/� ' 7 IG / ) FACE 0r r1TPA'G TO —L �- n'aL! D/MENSr ^! 1!4 "MIN. 'v .r ,.1 :.8mrnj 1-7..;..,,,,m] 1-7..;..,,,,m] " r, , E — 2 1/4" HOLE DIA. s'— f" d p r :� 1 %.m] fJ n • 1/3- I 152.4mmf i'. ill{ 1 � 2'n J 7 CEILING ID < .' . 4 V 1" k 1/2" REDUCER � OCrL CCTJ,7 1 15/16 0 i.. 11 Horizontal Sidewall 1'49.2, —, - . — 4 ' r r ` - "" �� (72.2mm) ' r L-:� tti,l r TURN COLLAR ONTI! J \ r TIGHT AGAINST SPRINKLER `, WRENCH BOSS. l� (I) AUJVS r Af! ,V / ( 1 ) REFER TO ESCU.TH'EON OArA TABLE FOR APPROVALS AND DIfr4ENS.CNS. 3. I . . Installation Quick response sprinklers are intended for installation as cleaning fluids. Remove dust by using a soft brush or gen- specified in NFPA 13. Quick response sprinklers and stan- tie vacuuming. Remove any sprinkler which has been dard response sprinklers should not be intermixed. painted (other than factory applied) or damaged in any ° The Model F1FR Recessed Quick Response Sprinklers are to way. A stock of spare sprinklers should be maintained to be installed as shown. The Model Fl or F2 Escutcheons illus- allow quick replacement of damaged or operated sprin- trated are the only recessed escutcheons to be used with the klers. Prior to installation, sprinklers should be maintained Model Fl FR Sprinklers. The use of any other recessed escutch- in the original cartons and packaging until used to mini- eon will void all approvals and negate all warranties. mize the potential for damage to sprinklers that would When installing Model Fl FR Sprinklers, use the Model D Sprin- cause improper operation or non - operation. . kler Wrench. When installing Model Fl FR Recessed Pendent or ' Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any Sprinkler Types other type of wrench may damage these sprinklers. Standard Upright Glass bulb sprinklers have orange bulb protectors to minimize Standard Pendent bulb damage during shipping, handling and installation. RE- . MOVE THIS PROTECTION AT THE TIME THE SPRINKLER Conventional ' SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- Sidewall (Vertical, Horizontal HSW1) moval of the protectors before this time may leave the bulb vul- Recessed Pendent • nerable to damage. RASCO wrenches are designed to install Recessed Horizontal Sidewall HSW1 • sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Finishes (1) (2) • TO REMOVE THE PROTECTORS. . . Standard Finishes Temperature Ratings Sprinkler I Escutcheon • Bronze Brass . Sprinkler Max. Ambient Bulb Chrome Plated Chrome Plated fat Classification Temperature Temp. - Color White Polyester C oate d White Painted fat °C °F Ordinary 57 135 1oo°F (38°C) Orange Special Application Finishes Ordinary 68 155 100°F (38"C) Red 'Sprinkler Escutcheon . . Intermediate 79 175 150°F(66°C) Yellow Bright Brass Bright Brass • . Intermediate 93 200 ' 150°F(66 °C) Green Black Plated Black Plated High (1) 141 286 225 °F(107°C) Blue , Black Paint Black Paint • ' (') Not available for recessed sprinklers. on White Off White • . Escutcheon Data Satih Chrome Satin Chrome ' Face ofF1tting 1 Other finishes and colors are available on special order. Escutcheon App A toCaTiingor Consult the factory for details.' amension modei . Wall Dimension 12) FM Approvals is limited to bronze and brass, chrome or black 1/ n plated finishes only. Max Recess (38.1mm) Y."- '';e" 13) FP Push - on/Thread -off escutcheon F1 1,2.4,8 Min Recess ri " (5mm -24mm) ' (19.1mm) Ordering Information ix Specify: • F2 1 , 2 , 3 . 4 , 5 , 7 , 8 Max Recess (38.1mm) 3;6'- };e" Min Recess ' 3; " (5mm -17mm) 1. Sprinkler Model . . (24mm) 2. Sprinkler Type . . FP 1,2 Max Recessed 1 (11 6" 1/ (38.1mm) 3. Orifice Size wshoN 4. Deflector Type - ' Thread -off . 1,2 Min Recessed tY,6 1" (25.4mm) - • (24mm) 5. Temperature Rating No Dimensional Figure for FP 6. Sprinkler Finish 7. Escutcheon Type . - Maintenance • 8. Escutcheon Finish (where applicable) • . The Models F1FR and . F1FR Recessed Sprinklers should be inspected quarterly. and the sprinkler system Note: When Model F1FR Recessed sprinklers are maintained in accordance with NFPA 25. Do not clean ordered, the sprinklers and escutcheons are packaged sprinklers with soap and water, ammonia or any other separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fee Protection Association. Factory, Mutual Research . Corporation,.or other similar organizations and•atso with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting lite and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by - • . The Rel iable Automatic Sprinkler Co., Inc. Pepe Re e , (800)431 -1588 (800)84 -60 Sales Offices Sales Fax Revision lines indicate updated or new data (914)668-3470 Corporate Offices vnvw.reliabiesprinkter.com Internet Address EG. Primed in 11.5 A. 7 /OS PIN9999970027