Loading...
Specifications FR5 2o0 9' -a to . • )3 z7_ i 51A/ 6 Bulletin 148 Rev.0 -. 2--C-I'd co Re Model F1 FR ® Model F1FR Recessed Quick Response Extended co - Coverage Sprinklers A complete line of UL Listed and FM Approved quick response extended coverage - sprinklers for light hazard applications. - r — _ Horizontal Sidewall Sprinklers are approved .��: for installation 4" - 12" (102mm - 305mm) � . � �' '1 ,, \ • below the ceiling. � �" - Model Fl FR QREC Sprinkler Types : - ` . Extended Coverage Pendent ��..�, Extended Coverage Horizontal Sidewall Extended Coverage Recessed Extended • EC -8 Deflector Pendent Coverage Pendent • EC -9 Deflector Model Fl FR QREC Recessed Sprinkler T yp es '; Recessed Extended Coverage Pendent ` ` - = `' - � % "'` Recessed Extended Coverage Horizontal '� k �,=- -� - _ ' Sidewall: ,‘ ;v; • EC -8 Deflector . • EC -9 Deflector Approval Organizations Extended Coverage Recessed Extended 1. Underwriters Laboratories, Inc. Horizontal Sidewall EC -8 Coverage Horizontal Sidewall 2. Underwriters' Laboratories of Canada EC -8 3. Factory Mutual Research Corporation 4. NYC MEA 258 -93 -E , , UL Listin Category `� c Mi i N.:..,. � , Sprinklers, A utomatic & Open -- ' ' 0 , Quick Response Extended Coverage Sprinkler ° -'y = { mtair _ � � ,1 ' ; f - tom f1- :_ . , ` UL Guide Number s'. i VNIV f' ,.,,�. � Note: Consult appropriate FM Installation Standards . regarding limitations of room size, ceiling height and minimum wall fire resistance rating. Extended Coverage Recessed Extended Horizontal Sidewall EC -9 Coverage Horizontal Sidewall Product Description EC -9 Reliable Models F1FR QREC and F1FR QREC • Recessed Sprinklers are quick response sprinklers which The balance of parts are made of brass, copper and combine the durability for a standard sprinkler with the beryllium nickel. attractive low profile of a decorative sprinkler. The temperature rating of the sprinkler is identified by The Models F1FR QREC and F1FR QREC Recessed the color of the glass bulb. Automatic Sprinklers utilize a 3.0mm frangible glass. bulb. These sprinklers have demonstrated response times in Application laboratory tests which are five times faster than standard response sprinklers. This quick response enables these Quick response sprinklers are used in fixed fire P P q P protection systems: Wet, Dry, Deluge or Preaction. Care • sprinklers, to apply water to a fire much faster than must be exercised that the orifice size, temperature standard sprinklers of the same temperature rating. rating, deflector style and sprinkler type are in ‘ The glass bulb consists of an accurately controlled accordance with the latest published standards of the . amount of special fluid hermetically sealed inside a National Fire Protection Association or the approving precisely manufactured glle. thermal ass This gl bulb is authority having jurisdiction. Quick response sprinklers specially constructed to provide ass capsu fast response. are intended for installation as specified in NFPA 13. • The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 '