Report IFF 403/26/04 FRI 14:36 FAX 503 684 0954 CARLSON TESTING 41002 Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 Carlson 'testing Inc. Tigard, Oregon 97 Salem, Bend. OR 97708 Phone (603) 684-3460 Phone (503) 3) 589 9 1212 52 Phone (541) 330 9155 9 FAX (503) 684 -0954 FAX (503) 589.1309 FAX (541) 330 -9163 Special Inspection FINAL SUMMARY LETTER March 26, 2004 RECEIVED T0405041 MAR 2 9 2004 CITY OF TIGARD City Tigard FILE Copy BUILDING DIVISION 13125 SW Hall Blvd., Tigard, OR 97223 -8199 Attn: Steve Martin/ Building Department , Re: Open Shelter @ Summerlake Park 145 "d Tigard, OR Permit No.: BUP2003 -00616 Dear Steve: This is to certify that in accordance with Section 1701 of the Uniform Building Code, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Concrete Epoxy Anchors CTI was notified by Steve Martin, of the City of Tigard, that site welding was not a special inspection requirement on this project, thus no inspection was performed. All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If them re any further questions regarding this matter, please do not hesitate to contact this office. Res • - ully submitted, _ CA' SON TESTIN . mes F. Hietpas operations Manager cc: Zeyn B Ozman PE Precision Commercial Contractors •/1 1'al l.Zvu a'nA •.vo VV Vuu-a Vna \aAuVl• all Taa .rjvv- Main Office Salem Office Bend Office ..� P.O. Box 23814 4660 Hudson Ave., NE P.O. Box 7918 'Tigard, Oregon 97281 Salem, OR 97301 Bend, OR 97708 Carlson Testing Inc • Phone (503) 684 -3460 Phone (503) 589 -1252 Phone (541) 330 -9155 FAX (503) 684 -0954 FAX (503) 589 -1309 FAX (541) 330 -9163 Special Inspection FINAL SUMMARY LETTER ` oR `o06 March 26, 2004 �` " o� T0405041 � � /yam City of Tigard 13125 SW Hall Blvd., Tigard, OR 97223 -8199 Attn: Steve Martin/ Building Department Re: Open Shelter a Summerlake Park Tigard, OR Permit No.: BUP2003 -00616 Dear Steve. This is to certify that in accordance with Section 1701 of the Uniform Building Code, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Concrete Epoxy Anchors CTI was notified by Steve Martin, of the City of Tigard, that site welding was not a special inspection requirement on this project, thus no inspection was performed. All inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code. and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested /inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there - re any further questions regarding this matter, please do not hesitate to contact this office. Resp submitted, _ CAIV' SON TESTIN . 4 mes F. Hietpas Operations Manager cc: Zeyn B Oxman PE Precision Commercial Contractors