Loading...
Report ' ,r M ( t • • ,. Main Office Salem Office Bend Office P.O. Box 23814 4060 Hudson Ave., NE P.O. Box 7918 regon 97281 Tigard, Phone (503) 684 3460 Phon Salem, e (503) 589 1252 Phone (541) 330 -9155 C a..rl s on Testing, Inc • FAX (503) 684-0954 FAX (503) 589-1309 FAX (541) 330 9163 Special Inspection • FINAL SUMMARY LETTER February 7, 2003 - T0202038 P.O. No.: Tigard03- 112902 City, of Tigard FILE • 13125 SW Hall Blvd., OP r Tigard, OR 97223 -8199 Attn: Building Department - • Re: . Red Robin Restaurant @ Washington Square II 10100 SW Washington Square Rd — Tigard, OR Permit No.: BUP2002 -00409 . Dear Sir or Madam: This is to certify that in accordance with Section 1701 of the Uniform Building Code and Chapter 24.20, Title 24, we have performed special inspection of the following item(s) per our inspection reports only: Reinforcing Steel - • - Concrete -- Compressive Strength Testing Installation of Epoxy Anchors Structural Steel- Field, Includes Verification of Welder Certifications, Material Certifications and Weld Procedures All•inspections and tests were performed and reported according to the requirements of Project Documents and, to the best of our knowledge, the work was in conformance with the approved plans and specifications, approved change orders and applicable workmanship provisions of the State Building Code and Standards, as well as the structural engineer's design changes, approvals and verbal instructions. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are : ny further questions regarding this matter, please do not hesitate to contact this office. Respe - ly submitted, CARLS 4 , TESTING, INC. . i/ • • Jam': ' . Hietpas • Qua Assurance Manager JF /Is • Red Robin .Gourmet Burgers.— Carolyn, Miller Devcon .Inc — Dave Stephenson Chipman Adams Ltd — Matt Raasakka P:\WORDIREPORTS\FI NLTR\T0202038 CARLSON TESTING, INC. 4- INCOMPLETED ITEMS LIST (NCL) February 7, 2003 T0202038.CTI Project Name: Red Robin Restaurant @ Washington Square II Project Address: 10100 SW Washington Square Rd — Tigard, OR Permit No: BUP2002 -00409 DATE ITEM # INSP. DATE ITEM DESCRIPTION COMPLIANCE CTI SIGN -OFF CORRECTED Anchor at B.3, 4.9, southeast anchor, only 7" As -built condition acceptable per 1 JH 11 -22 -02 embedment — hit resteel. letter dated February 7 , 2003 J. Hietpas 02 -07 -03 from E.O.R. Anchor at A.9, 4.9, northwest anchor, only 7" As -built condition acceptable per 2 JH 11 -22 -02 embedment — hit resteel. letter dated February 7 2003 J. Hietpas 02 -07 -03 from E.O.R. 3 JK 12 -03 -02 No welder certifications or WPS's on site. Received. J. Hietpas 02 -0703 cc: Red Robin Gourmet Burgers — Dan Thompson City of Tigard Building Dept Devcon Inc — Dave Stephenson Chipman Adams Ltd — Matt Raasakka R.I. JOHNSON & ASSOCIATES, LTD. CONSULTING ENGINEERS (630) 653 -9060 • FAX (630) 653 -9059 February 7, 2003 'VS gag] Mr. Ariel Delao FILE COPY r . 1 0 2003 p s, Ltd. Chi man /Adam oAN►S►Mp A 1550 N. Northwest Hwy. - 4 Floor o� IP �,�tN CHITECTS .TD. Park Ridge, Illinois 60068 Re: Red Robin - Tigard, Oregon Field Test Results RIJA Job No. 2002517 Dear Ariel, We have completed our review of the two field test reports which indicated several items did not meet the requirements of the construction documents. The first concerned the embedment depth (7" as -built versus 9" design) of one of the four column anchor bolts at two locations. The second concerned the twenty -eight day concrete strength for the continuous footing below the trellis. The construction documents indicated 3,000 psi concrete was required, however, a value of 2,700 psi was obtained at this location. These as -built conditions are structurally acceptable. If you have any questions please don't hesitate to call. Sincere) /A:),S.0 PR OFS 411117/ � ft '� G I N E /r • 62686 Robert I. Johnso , ' . � R. I. Johnson & Associates, Ltd. - Pre de t OREGON RIJ:naw /mjw \\ 1 0 ,417)1 ! s, i� FRr /. joN‘' Attachment: Test Results EXPIRES DA 175 N. WASHINGTON ST. WHEATON ILLINOIS 60187