Loading...
Correspondence July 2, 2007 City of Tigard, Oregon Tigard Building Department 13125 SW Hall Blvd. ABBOT + ABBOT Tigard, OR 97223 ARCHITECTS, P.L.L. Dan Nelson, Senior Plans Examiner (503) 718 -2436 Re: Permit #'s BUP2007 -00288 & MEC2007 -00288 Ruehl @ Washington Square Mall 9524 SW Washington Sq. Space H08 Tigard, OR 97223 Dear Sir, This letter is in response to your plan review correction letter dated June 19, 2007. Permit #BUP2007 -00288 1. Calculations and diagrams showing support for walls, storefronts, etc., for lateral and vertical load per ASCE7 9.6.1.3. a. Calculations have been included, corrections for additional bracing have been added to sheets A00.9, A08.3, A08.4 and A08.6 2. Taking in consideration the exceptions in OSSC 603.1, provide noncombustible construction throughout. a. All of the exposed combustible construction is not structural, thus not governed by OSSC 603.1, but by OSSC 803 Wall and Ceiling Finishes. Table 803.5, Use Group M, Rooms and Enclosed Spaces allows a Class C flame spread rating. Furthermore all of the wall and ceiling finishes are separated from the structure by a layer of 5/8" gypsum board. ‘C Permit #MEC2007 -00288 `U 1. Calculations and diagrams showing support for VAV boxes for lateral and vertical load per ASCE7 9.6.1.3. a. Calculations have been included. In addition to these comments /revisions there have been some revisions to the plans per Landlord & the Owner comments /requirements. Please review the attached Revision Bulletins If you have any additional questions please call. Sincerely, William E. Abbot, Abbot + Abbot Architects 130 East Chestnut Street, Suite 302, Columbus, Ohio 43215 -2543 phone: 614.461.0101 fax: 614.461.1107 www.abbot- abbot.com WWI _15 ,.A . mac doYY ___Lewilo_i_----, s------J--774 --,0 r71 DI )-0(P1/4 REVISION BULLETIN ABBOT + ABBOT ARCHITECTS, P.L.L. AA#: 12070010135 Revision #:1 Revision Date: 6/27/07 Division: Ruehl Project: Washington Square Location: Tigard, Or This bulletin, if issued after the execution of the contract, described proposed revisions of the contract documents and requests from contractor, the amount of change, if any, in contract sum to accomplish the work described. It is assumed no change in contract time will be necessary unless contractor submits written request for time extension, including justification, with his proposal for work described in this bulletin. Except as otherwise described herein, or as shown on drawings issued with this bulletin, current contract documents apply to proposed work. This bulletin is not an order to do work. After receipt and review of the proposal requested, a change order will be issued to authorize execution of the work, or portion thereof, if the owner so directs. Proposals: Submit proposals for change described herein on contractor's letterhead. List each item individually as listed below: SHEET DESCRIPTION A00.0 Corrected index of drawings A00.5 Revised Responsibility Schedule A00.9 Bracing details modified per Building Department comments A01.2 Added Landlord notes; Barricade by Landlord at Tenants expense A02.1 Added additional framing for cabinet support Leather shop and Mens2; corrected fitting room numbering; revised storefront at neutral piers; eliminated access to unused space. A02.2 Corrected fitting room numbering A03.1 Revised storefront at neutral piers — Unused space is now Void Space. Corrected pass -thru height from Leather Shop to Leather Shop; Revised Mudroom 'false' beam dimensions. A04.1 Revised storefront at neutral piers — Unused space is now Void Space; removed associated lighting; revised Mudroom light dimensions A04.3 Revised storefront at neutral piers — Unused space is now Void Space. A05.1 Revised storefront at neutral piers — Unused space is now Void Space. Voided detail 'C' A05.2 Added waterproof membrane note for Restrooms A06.1 Revised storefront at neutral piers — Unused space is now Void Space. A07.1 Revised elevations 'A & B' A07.2 Revised elevation 'A' Page 1 of 2 130 East Chestnut Street, Suite 302, Columbus, Ohio 43125 -2543 phone: 614.461.0101 fax: 614.461.1107 www.abbot - abbot.com \\ e1 1 ' S ABBOT + ABBOT ARCHITECTS, P.L.L. A07.4 Revised details 5, 6 & 22 A08.1 Revised Storefront Elevation & Plan per Landlord comments; A08.2 Revised Details F, G & H A08.3 Revised Storefront Sections A, B & C per Landlord comments A08.4 Revised Storefront Sections A, B & C per Landlord comments A08.5 Revised detail C A08.6 Revised Storefront Sections /Elevation A, B & E per Landlord comments A08.7 Revised Storefront Elevation & Plan per Landlord comments; A11.1 Revised detail H & K A11.3 Revised detail C, dimensions A11.4 Revised detail C, hanger notes A11.8 Revised detail D Al2.2 Revised detail A MEP Refer to document — MEP - 135- RV1- 06- 27 -07.doc for MEP revisions I End of Bulletin I Signed by: Don Schumacher 614.461.0101 x243 Dschumacher @abbot - abbot.com Date: 7 -2 -07 Copies To: File Page 2 of 2 130 East Chestnut Street, Suite 302, Columbus, Ohio 43125 -2543 phone: 614.461.0101 fax: 614.461.1107 www.abbot- abbot.com 1 °Z'' Emphasis on Excellence M•Retail Engineering, Inc. Landlord Comments, B.D. Comments - Revision #1 Date To Re June 27, 2007 GC for Ruehl Ruehl Store #135 Washington Square 9585 Washington Square Rd. Tigard, OR 97223 Revision No. 1 Please incorporate the following clarification / revision into your bid price. NOTE: WE ARE ISSUING ALL ADDENDA TO THE G.C. BIDDERS FOR CLARIFICATION AND COORDINATION. Sheet M01.1 No Change. Sheet M01.2 No Change. Sheet MD1.1 Added VAV detail per B.D. comments. Sheet MD1.2 Added Landlord notes per Landlord Comments. Sheet MS1.1 No Change. Sheet P01.1 Added Landlord notes per landlord comments. Added note to dream steamer detail per tenant directive. Sheet P01.2 Revised coded notes per Landlord Comments. Sheet P01.3 Removed roof routing of gas pipe per Landlord comments. Sheet FP1.1 Added Landlord note per Landlord Comments. Sheet FP1.2 Added Landlord note per Landlord Comments. Sheet E01.1 Removed receptacle in women's 1 and revised cash/wrap conduits per tenant directives. Sheet E01.2 Revised coded note #21 per tenant directives. Sheet E02.1 Removed skylight fixtures in mudroom and garage per tenant directives. Removed lighting in unoccupied space per tenant directives. 750 BROOKSEDGE BLVD. • WESTERVILLE, OHIO 43081 Page 1 of 2 614 -818 -2323 • FAX 614 -818 -2337 • E-MAIL mretallem-corporations.com An M *Corporation • 11 " Emphasis on Excellence M•Retail Engineering, Inc. Sheet E02.2 Revised master lighting switch bank and coded note #20 per tenant directives. Sheet E03.1 No Change. Sheet E04.1 No Change. Sheet E04.2 No Change. Sheet ED1.1 No Change. Sheet ED1.2 Revised sales area emergency light specification in lighting fixture schedule per tenant directives. Sheet ES1.1 No Change. 750 BROOKSEDGE BLVD. • WESTERVILLE, OHIO 43081 Page 2 of 2 614 -818 -2323 • FAX 614 -818 -2337 • E-MAIL mretailQmcornorations.com An M *Corporation