Loading...
Plans L CITY OF TIGARD Approved . [ 7 ] t ona ionany approved t ] For only the work as described in: 1 PERMIT NO. it/ C a-v0,� - ( • (7oUR�J n i Tf 7 C / 7 ' ✓et la C rG ) See Letter to: Follow [ ] . • h tc of i Attach [ l A v C l^ r 5 k i t y Job • . roes: • - • 4 •= e • y By: Date: • - 2 -07— r AC -2 AC -3 EF -2 EF -3 R4 . EF-1 I AC 4 0 .1 S AC -1 R_5 EF -5 RH EF -4 0 0 Customer: Project: American Heating, Inc. TGI Fridays Restaurant Equipment Repair 1339 SE Gideon Street 10145 SW Washington Sq. Rd. Equipment Replacement Tigard, OR 97223 Portland, OR 97202 6 F r 1 C _... - - --- -... ------- . -- � � - l - — — ----t---REF � • : 1 E. F.# p i \ - 4- r - ON LA 3 b • 3N LA- ■ WP 1 30/1 REF. COMP. "C" 1 8 P SEE DWG .E-3-- 30/3 Q STARTER I N, WP LEC. RM. CC� PA -3l • C . T. DRA I N 1 -= FOR CCT' S . s 0 ' t r - - -- - - -- - - ...- - - - �a PD -6,8 .. P. •�, =' 4 "O. F. COND. WATER PUMP . NOTE 5 45WP �-� 4''O.F. A/C 1 kr`I�s � / A , 'WP 6l "RD - NOTE 6I ■ .. 4) ■ l0O a r Rif '- '‘ • .100/3 30/2 ` 12 "CS DN. u i C-1-- L-4 "RD /a WP, /--PP-14,16, WP • _ c �4 AJC #4 3 /4 "CW M.U. ' E.F. #I (r' €-- M/�tot• • _, " }SO MAL 12 "CR DN s MI 3/4 " _ 4 . 1 PD- I d , 12 200 /3 1 i • PP-1,3,5 ID © 9 ON LA -31- P -36,38 F OR _ LA -31 i 3a �� ■ 1 BASIN HEATE . - - - - — - , 1 r -.41 i • I w s PP -8 10 ,� • WP 1 I 1" , '1 PP- 19,21,23 PP-7,9, 1 .: 2 -- D t w 200/3 t 11.n_, LL ' d '/y 11 I 3/4" . 1 A/C TO STARTER • 1 3 I a i' 1 m. 6 100/3 ELECT.RM WP R 5 PA • 3/4" PA 5 E.F CCT. PA -32 o M H \ re IV Xbr0 III v ■ \MnYI WP PP- 13, 7 _ P P}- 2 , 4 , 6 \-, ac ■ , P 1 I ziP. J ( lJ 6 Dais 4 v .\ �. 100/3 �- w f�,ve UnI i . WP • A /C #2 , �o Ms u. co 30/3 - ON LA -31 , .� ` `ON LA -31 . E o wP o 2 .. ' WP ::•\•'*,-.. \ • [ i \ _ - - __ __ . • 7..,- - PACKAGED GAS / ELECTRIC LENNOX GCS16 - 024 -030- 036-048-060 ENGINEERING DATA 2 to 5 Ton (7.0 to 17.6 kW) AFUE - 80% pE11GN �, SEER - up to 10.35 4. 16 , ��f Net Cooling Capacity - 23,200 to 58,500 Btuh (6.8 to 17.1 kW) \ r \ S. • 3 Input Heating Capacity - 50,000 to 120,000 Btuh (14.7 to 35.2 kW) - \ `° 4 oS * ' Bulletin No. 210169 cf gTlnd , September 2001 Supersedes December 2000 G eNnaena _ _ � " ni a ,,. em u , am i _ � y-- V -4 . f .— . _ / . . f * . ''''''''''''\N'''::\' ; *; - Rooftop Installation With Comb � ' Supply and Return Air System r �i F GCS16 14 I !3 Ba Unit i � / . Rooftop Installation With Horizontal Economizer MODEL NUMBER IDENTIFICATION GCS 16 X - 036 - 120 - 1 Y I Unit Type J L voltage GCS = Packaged Gas Heat/Cooling Unit P = 208/230v -1 phase -60hz Series Y = 2081230v -3 phase -60hz G = 460v -3 phase -60hz Low NO„ Models J = 575v -3 phase -60hz Minor Revision Number Cooling Capacity Tons (kW) 024 = 2 (7.0) 030 = 2.5 (8.8) — Heating Capacity Btuh (kW) 036 = 3 (10.6) 50 = 50,000 (14.6) 048 = 4 (14.1) 75 = 75,000 (22.0) 060 = 5(17.6) 90= 90,000(26.4) 120 = 120,000 (35.1) FEATURES Application - AFUE of 80 %. - SEER up to 10.35. - 2 through 5 ton (7.0 through 17.6 kW). - Single and three phase power supply. - Bottom (down -flow) or horizontal supply and return air. - Designed for outdoor rooftop or ground level installations in light commercial applications. Approvals - Certified in accordance with the USE certification program, which is based on ARI Standard 210/240 -94. - Sound rated in the Lennox reverberant sound test room in accordance with test conditions included in ARI Standard 270 -95. - Tested in the Lennox Research Laboratory environmental test room. - Rated according to U.S. Department of Energy (DOE) test procedures. 1 - Blower data is from unit tests conducted in the Lennox Laboratory air test chamber. i - Units certified by CSA International (formerly AGA/CGA) and ratings are certified by GAMA. - Gas heat is tested according to DOE test procedures and FTC labeling regulations. - All "X" models meet California Nitrogen Oxides (NO standards and California Seasonal Efficiency Requirements. - Developed in accordance with ISO 9002 quality standards. - Each unit test operated at the factory before shipment ensuring dependable operation at start-up. NOTE - Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. ©2001 Lennox Industries Inc. , ° Installation and service must be performed by a qualified installer and servicing agency. SPECIFICATIONS T Heating Model No. GCS16 -048 -75 GCS16 -048 -120 GCS16 -060 -75 GCS16 -060 -120 Performance Low NO Models GCS16X -048 -75 GCS16X -048 -120 GCS16X -060 -75 GCS16X -060 -120 Input - Btuh (kW) 75,000 (22.0) 120,000 (35.2) 75,000 (22.0) 120,000 (35.2) Output - Btuh (kW) 60,000 (17.0) 96,000 (28.1) 60,000 (17.0) 96,000 (28.1) yrA.F.U.E 80.0% 80.0% 80.0% 80.0% Gas Supply Connections npt - in. 1/2 1/2 1/2 1/2 Rec. Gas Supply Pressure in. w.c. (kPa) Natural Gas 7 (1.7) 7 1 7 ( ) 7 (1.7) 7 (1.7) LPG /Propane 11 (2.7) 11 (2.7) 11 (2.7) 11 (2.7) Cooling Nominal Tonnage (kW) 4 (14.1) 4 14.1 Performance ( ) 5 (17.6) 5 (17.6) *Cooling capacity - Btuh (kW) 46,500 (13.6) 46,500 (13.6) 58,500 (17.1) 58,500 (17.1) Total unit watts 4890 4890 6570 6570 *SEER (Btuh/Watts) 10.35 10.35 10.00 10.00 EER ( Btuh/Watts) 9.5 9.5 8.90 8.90 *Sound Rating Number (db) 82 82 82 82 Refrigerant Charge (HCFC -22) 5 lbs. 11 oz. 5 lbs. 11 oz. 7 lbs. 0 oz. 7 lbs. 0 oz. (2.58 kg) (2.58 kg) (3.18 kg) (3.18 kg) Condenser Net face area - sq. ft. (m Outer coil 14.3 (1.33) 14.3 (1.33) 14.3 (1.33) 14.3 (1.33) Coil Inner coil 5.9 (0.55) 5.9 (0.55) 13.7 (1.27) 13.7 (1.27) Tube diameter - in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) \No. of rows 1.4 1.4 2 2 Fins per inch (m) 20 (787) 20 (787) 20 (787) 20 (787) Condenser Diameter - in. (mm) & No. of blades 24 (610) - 4 24 (610) - 4 24 (610) - 4 24 (610) - 4 Fan Air volume - cfm (Us) 3880 (1830) 3880 (1830) 3770 (1780) 3770 (1780) Motor horsepower (W) 1/4 (187) 1/4 (187) 114 (187) 1/4 (187) Motor watts 340 340 360 360 Evaporator Blower wheel nominal diameter x width - in. (mm) 11 -1/2 x 9 11 -1/2 x 9 11 -1/2 x 9 11 -1/2 x 9 Blower (292 x 229) (292 x 229) (292 x 229) (292 x 229) Motor horsepower (W) 3/4 (560) 3/4 (560) 3/4 (560) 3/4 (560) Evaporator Net face area - sq. ft. (m Coil (m 5.3 ( 0.49 ) 5.3 (0.49) 6.2 (0.58) 6.2 (0.58) Tube diameter - in. (mm) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) No. of rows 2 2 2 2 Fins per inch (m) 15 (591) 15 (591) 15 (591) 15 (591) Condensate drain coupling size npt - in. 3/4 3/4 3/4 3/4 No. & size of cleanable polyurethane filters - in. (mm) (1)20x25x 1 (508 x 635 x 25) Shipping Net weight of basic unit - lbs. (kg) 496 (225) 496 (225) 526 (239) 526 (239) Data Shipping weight of basic unit - lbs. (kg) 1 pkg. 605 (274) 605 274 ( ) 635 (288) 635 (288) Electrical characteristics (60hz) 208/230v - 1 ph, 208/230v - 1 ph, 208/230v - 1 ph, 208/230v - 1 ph, 208/230v or 208/230v, 460v or 208/230v or 208/230v, 460v or 460v - 3 ph 575v - 3 ph 460v - 3 ph 575v - 3 ph *Sound Rating Number in accordance with test conditions included in ARI Standard 270. *Annual Fuel Utilization Efficiency based on DOE test procedures and FTC labeling regulations. *Certified in accordance with the USE certification program, which is based on ARI Standard 210/240: 95 °F (35 °F) outdoor air temperature and 80 °F (27 °C) d 7 °F (19 °C) wb entering evaporator coil air. HIGH ALTITUDE INFORMATION g g No 7500 ft. (0 to 2285 m t needed . Seebelow or correct ct manifold press 0 pressures for natural gas and LPG /propane. FUEL Manifold Pressure (outlet) 0 to 7500 ft. (0 to 2248 m) above sea level Natural Gas 3.5 in. w.g. (0.87 kPa) LPG/Propane 10.5 in. w.g. (2.61 kPa) 4 . GCS16 - 2 to 5 Ton / Page 6 ,. • PACKAGED L SERIES LENNOX 088 and 100 MODELS LCA /LGA /LHA "LCA" PACKAGED COOLING & ELECTRIC HEAT LCA/LGA - 7.5 & 8.5 Ton I (-) ENGINEERING DATA "LGA" PACKAGED COOLING & GAS HEAT (26.4 & 29.9 kW) "LHA" PACKAGED HEAT PUMP LHA - 7.5 Ton *Net Cooling Capacity - 85,000 to 94,000 Btuh (24.9 to 27.5 kW) (26.4 kW) Gas Input Heating Capacity - 83,000 to 180,000 Btuh (24.3 to 52.8 kW) Bulletin February ary 1 999 1999 *Heat Pump Heating Capacity - 86,000 Btuh (25.2 kW) Supersedes May 1998 Optional Electric Heat - 7.5 to 45 kW 'AR Certified Ratings IC ) , - ---- - I , 1 - - : ,,,.: --',, , „ , ,,,,, : ., . - lA tt,. _ t P . 0 4 /8TO O \' t ' \ .g ,� ,; . � , ` a ,...:ro,,, - 1 ( I 3. N � ° x ,c CS ..... ��. •� VERIFIED a/t% -' i tA■■ ENERGY NM\ PERFORMANCE LCA088 (Cooling & Electric Heat) a • i — _ , Mr '.s.� r , ire � m tf� - LGA088 .• LHA088 (Cooling & Gas Heat) (Heat Pump) Table of Contents Features Page 2 -3 Field Wiring Page 15 Factory Installed Only Options Page 4 Electric Heat Data - LCA088 Page 16 Field and/or Factory Installed Accessories Page 4 -5 Electric Heat Data - LCA100 /LHA088 Page 17 Temperature Control Systems Page 5 -8 Cooling Ratings - LCA/LGA Models Page 18 -19 Temperature Control Selection Flowcharts Page 8 -10 Cooling & Heating Ratings - LHA Models Page 19 Model Number Identification Page 10 Blower Data Page 20 -21 1 Specifications - LCA/LGA Page 11 Guide Specifications Page 22 J Specifications - LHA Page 12 Dimensions - LCA Models Page 23 Weight Data Page 13 Dimensions - LGA Models Page 24 Optional Electric Heat Accessories Page 13 Dimensions - LHA Model Page 25 Electrical Data Page 14 Dimensions - Accessories Page 26 -27 High Altitude Derate — LGA Models Page 14 Installation Clearances Page 27 NOTE — Due to Lenox' comnittment to quality, Specifications, ©1999 Lennox Industries Inc. ongoing q ty, peafications, Ratings and Dimensions subject to change without notice and without incuring liability. • t( SPECIFICATIONS - LCA /LGA MODELS ' Model No. LCAlLGA088 ' LCA/LGA100 Efficiency type Standard (S) High (H) Standard (S) 0 Gross Cooling Capacity - Btuh (kW) 94,000 (27.5) 90,000 (26.4) 100,000 (29.3) Cooling )]Net Cooling Capacity - Btuh (kW) V 88,000 (25.8) 85,000 (24.9) 94,000 (27.5) Ratings Total Unit Power (kW) 9.77 8.33 10.44 Di EER (Btuh/Watt) 9.0 10.2 9.0 [Integrated Part Load Value (Btuh/Watt) 9.2 10.4 9.0 MSound Rating Number (db) 8 Refrigerant Circuit 1 T S lbs. 0 oz. 8 lbs. 8 oz. 8 lbs. 8 oz. Charge (3.63 kg) (3.86 kg) 9) (3.86 kg) (HCFC-22) Circuit 2 8 lbs. 0 oz. 8 lbs. 8 oz. 8 lbs. 8 oz. (3.63 kg) (3.86 kg) (3.86 kg) Heat Input Type Standard (S) High (H) Standard (S) High (H) Two Stage Input (low) - Btuh (kW) 83,000 (24.3) 119,000 (34.9) 83,000 (24.3) 119,000 (34.9) Heating Capacity I Output (low) ( ) ' (Natural or P (ow - Btuh kW 66,000 (19.3) 95,000 (27.8) 66,000 (19.3) 95,000 (27.8) LPG /Propane (High) Input h Gas P ( 9) - Btuh (kW) 125,000 (36.6) 180,000 (52.8) 125,000 (36.6) 180,000 (52.8) (at Sea Level) Output (High) - Btuh (kW) 100,000 (29.3) 144,000 (42.2) 100,000 (29.3) 144,000 (42.2) A.G.A. /C.G.A. Thermal Efficiency 80.0% Gas Supply Connections npt - in. - Natural or LPG /Propane 3/4 - Recommended Gas Natural 7 (1 7) Supply Pressure - wc. in. (kPa) LPG /Propane 11 (2.7) Blower wheel nominal dia. x width - in. (mm) (1) 12 x 12 (305 x 305) Nominal motor output - hp (kW) 2 (1.5) 2 hp (1.5 kW) Max. usable motor output - hp (kW) 2.30 (1.7) Evaporator ®Motor & Drives Voltage & phase 208/230v, 460v or 575v -3ph Blower and (Drive kit #) RPM range (1 or 2) 845 -1130 (3 or 4) 1015 -1300 ® Drive Selection Nominal motor horsepower (kW) 3 (2.2) 3 hp (22 kW) Max. usable motor output - hp (kW) 3.45 (2.6) ©Motor & Drives Voltage & phase 208/230v, 460v or 575v -3ph (Drive kit #) RPM range (1 or 2) 845 -1130 (3 or 4) 1015 -1300 Net face area - sq. ft. (m2) 9.72 (0.90) Tube diameter - in. (mm) & No. of rows I 3/8 (9.5) - 3 Evaporator Coil Fins per inch (m) 14 (551) Drain connection no. & size - in. (mm) fpt (1) - 1 (25.4) Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head Net face area - sq. ft. (m2) 23.78 (2.21) Condenser Coil Tube diameter - in. (mm) & No. of rows 3/8 (9.5) - 2 Fins per inch (m) 20 (787) Diameter - in. (mm) & No. of blades (1) - 24 (610) - 3 Total Air volume - cfrn (Us) _ 5300 (2501) Condenser Motor horsepower (W) - Fans 1/2 (373) Motor rpm 1075 Total Motor watts 550 Filters Type of filter Disposable Commercial Grade Pleated (furnished) No. and size - in. (mm) (4) 18 x 20 x 2 (457 x 508 x 51) Electrical characteristics 208/230v, 460v or 575v - 60 hertz - 3 phase MRated in accordance with ARI Standard 210/240 and certified to ARI; 95 °F (35 °C) outdoor air temperature and 80'F (27 °C) db/67° F (19 °C) wb entering evaporator air; minimum • external duct static pressure. NOTE -Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. aISound Rating Number rated in accordance with test conditions included in ARI Standard 270. III Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. RI Integrated Part Load Value rated at 80 °F (27 °C) outdoor air temperature. L Series 088 -100 / Page 11 ► Installed After Old Unit Inside of Existing Curb is Lifted Off the Curb I 3/8" x 1 '/2" Hex Head Bolts in —a1 Lo Q Q 4 "x4 "x4" 18 Gage Imi I Angle Iron / 1 / / HVAC Unit 1.-____________ t 0 1"x4" 18 Gage E;: ----- Galvanized Strap I Q ® #10x' / Sheet Metal tal E--- Outside Screws Outside of Curb Seismic Anchors for: Curb Anchors to the Roof Unit Anchors to Curb American Heating, Inc. 1339 SE Gideon Street HVAC Roof Top Curbs 4 "x4 "x4" 18 Gage Angle Iron 1 "x4" 18 Gage Galvanized Strap Portland. OR 97202 .,.. h r Russell All-Tern p 2 B tv..co‹_ i m 1■2are ran . Low Profile (•11..0c,tc !N Co 0LO Unit Cooler Publication No. 100.11 October, 2000 C US CI) N MEA r � J : fi 1 � + l0 5� , N r,x f .:+ Y J 1 p _ ma x, l'j::$.T!. FOR WALK -IN COOLERS AND FREEZERS 3,400 TO 39,000 BTUH STANDARD FEATURES • Available in Air, Electric and Hot Gas models. • Staggered copper tubes are expanded into corrugated • Flush to the ceiling mounting, meets NSF standards. Aluminum fins for increased heat transfer. • Slotted hangers provided for easy installation. • Internal placement of the defrost heaters allows for • Heavy guage, rust -free Aluminum housing. extremely rapid defrost. • Rust proof black plastic fan guards. • Separate defrost termination thermostat and fan delay • Angled drain fitting is sloped to reduce loss of useful thermostat with ideal location for each function. storage space by drain lines. • Heater safety control prevents over - heating of coil. • Computerized coil circuiting is used to enhance • Screw type terminal blocks are provided for easy performance for varying applications. wiring. OPTIONAL FEATURES • High efficiency PSC fan motors. • Coated wire fan guards for even air distribution up to • 460 volt motors and heaters. 25 ft. or epoxy resin high throw guards for up to 50 ft. • Coated Aluminum fins or Copper fins. • Reheat kits (not UL). • Baked white enamel housing. • Factory mounted expansion valves. " d--* • * RUSSell t Air Defrost / Specifications Model BTUH Total Fan Motor AMPS - 1 Phase Capacity ® 25° S.T. CFM Standard Motor Optional PSC Motor Number 10 °TD 12 °TD 115V 230V 460V 115V 230V AA18-41B 4100 4900 800 2.0 1.0 0.5 1.0 0.5 AA18 -53B 5300 6400 770 2.0 1.0 0.5 1.0 0.5 AA18 -66B 6600 7900 740 2.0 1.0 0.5 1.0 0.5 AA28 -768 7600 9100 1460 4.0 2.0 1.0 2.0 1.0 AA28 - 97B 9700 11600 1420 4.0 2.0 1.0 2.0 1.0 AA28 -106B 10600 12700 1540 4.0 2.0 1.0 2.0 1.0 d AA28 -122B 12200 14600 1380 4.0 2.0 1.0 2.0 1.0 u_ AA28 -134B 13400 16100 1480 4.0 2.0 1.0 2.0 1.0 co AA28 -160B 16000 19200 2310 6.0 3.0 1.5 3.0 1.5 AA38 -195B 19500 23400 2220 6.0 3.0 1.5 3.0 1.5 AA48 -212B 21200 25400 3080 8.0 4.0 2.0 4.0 2.0 AA48 -264B 26400 31700 2960 8.0 4.0 2.0 4.0 2.0 AA58 -275B 27500 33000 3850 10.0 5.0 2.5 5.0 2.5 AA68 -318B 31800 38200 4620 12.0 6.0 3.0 6.0 3.0 AA68 -390B 39000 46800 4440 12.0 6.0 3.0 6.0 3.0 AA16 -39B 3900 4700 830 2.0 1.0 0.5 1.0 0.5 AA16 -488 4800 5800 800 2.0 1.0 0.5 1.0 0.5 AA16 -58B 5800 7000 780 2.0 1.0 0.5 1.0 0.5 AA26 -70B 7000 8400 1540 4.0 2.0 1.0 2.0 1.0 AA26 -87B 8700 10400 1500 4.0 2.0 1.0 2.0 1.0 d AA26 -115B 11500 13800 1560 4.0 2.0 1.0 2.0 1.0 U_ AA36 -145B 14500 17400 2400 6.0 3.0 1.5 3.0 1.5 (0 AA36 -170B 17000 20400 2340 6.0 3.0 1.5 3.0 1.5 AA46-192B 19200 23000 3200 8.0 4.0 2.0 4.0 2.0 AA46 -2308 23000 27600 3120 8.0 4.0 2.0 4.0 2.0 AA56 -245B 24500 29400 4000 10.0 5.0 2.5 5.0 2.5 AA66 -295B 29500 35400 4800 12.0 6.0 3.0 6.0 3.0 AA66 -345B 34500 41400 4680 12.0 6.0 3.0 6.0 3.0 AA14 -42B 4200 5000 830 2.0 1.0 0.5 1.0 0.5 AA24 -848 8400 10100 1660 4.0 2.0 1.0 2.0 1.0 d AA24 -105B 10500 12600 1620 4.0 2.0 1.0 2.0 1.0 LL. AA34 -130B 13000 15600 2490 6.0 3.0 1.5 3.0 1.5 AA44 -170B 17000 20400 3320 8.0 4.0 2.0 4.0 2.0 AA54 -215B 21500 25800 4150 10.0 5.0 2.5 5.0 2.5 AA64 -255B 25500 30600 4980 12.0 _ 6.0 3.0 6.0 3.0 Ordering Information Required (1) Model number (2) Voltage, frequency and phase of motors and heaters (when applicable) (3) Refrigerant type (4) Evaporator remperature (5) Evaporator T.D. Model Numbering System A A 1 8- 4 1 B - Revision Code AII- Temp BTUH in hundreds Type of Defrost Fins per inch A = Air Defrost E = Electric Defrost H = Hot Gas Re -evap Number of Fans G = Hot Gas Rev. Cycle • a . Y ° � - H z$�� HOSHIZAK 3 I REMOTE CONDENSERS _ .$U U RC-F SERIES IC URC -6F Air Cooled Energy Efficiency and Quiet Operation URC -7F Air - Cooled URC -12F i Air - Cooled (1 /''^`'A`"- URC -20F Air - Cooled URC -24F Air - Cooled y o r � 24Wx181reDx323/4H with 15" legs 3713n6 W x 181/e D x 37 H with 15" legs URC-6F Remote Condenser ,- �x ;t 30�a W x 18ve D x 3413/16 H with 15" legs - URC -24F Remote Condenser 487/16 w x 18tre D x 41 H withl5 "legs 433/4Wx193/4Dx36H A, , zi , ® C ® lcemakers Sold Separately ". WARRANTY A rox. 24 Hr. Remote Use With PP Condenser 'icemaker Model Number Jae Production When used-with KM Series Cubers When used with F series Flakes 70°F/50°F 3 Year Parts & Labor entire unit. 1 Year Parts & Labor entire unit. 5 YEAR Parts: Air -Cooled Opndenler 2 YEAR Parts & Labor. Air- Cooled Condenser URC -6F KM- 500MRF Cuber 450 lbs. 5 YEAR Parts: Air - Cooled Condenser r k. URC -6F . KM- 630MRF Cuber 600 lbs. Warranty valid in United States, Canada, Puerto Rico, & U.S. Virgin URC - F - 1000MRF Flaker 920 lbs. Islands. Contact Factory for Warranty in other Countries, Territories, or URC 7F KML Cuber 635 lbs. Possessions. URC -12F KM- 900MRF Cuber 860 lbs. Features and Benefits of the URC URC -12F KM- 1300SRF Cuber 1193 lbs. Remote Air - Condensers for KM Series Cubers and F Series Modular URC - 12F KM Cuber 1296 lbs. Flakers provide quiet operation at the icemaker location, improve URC - 20F F - 2000MRF1 /3 Flaker 2000 lbs. efficiency, and save energy with cooler operation at the icemaker location. URC -20F KM- 1600MRF Cuber 1486 lbs. l Sturdy construction with weather - resistant cabinet finish for long life URC - 20F KM 1600MRF3 Cuber 1524 lbs. operation. Remote Condenser may be installed outdoors up to 55 feet URC - 20F KM - 1600SRF Cuber 1430 lbs. from icemaker using a pre- charged tubing kit. For installations URC - 20F KM - 1600SRF3 Cuber , 1461 lbs. exceeding 55 feet, contact Factory Service Department. URC -20F KM- 2000SRF3 Cuber 1865 lbs. ©HOSHIZAKI AMERICA, INC URC 24F KM 2400SRF3 Cuber 2330 lbs. The Power of Reliability,. 618 Hwy. 74 S., Peachtree City, GA 30269 FAX 1- 800 -345 -1325 TEL 1-800- 438-6087 www. hnshimki.corn Plan ViPw I I Side view n L_a /% A A" �. \ C Refrigeration i b t 1 C..ec e JrRr+iP Unit i E - 1 ► J n n Refrigeration Unit I Aflame . Detail Unistrut 4 "x6" L Pressure Treated P 3 Timber O 0.7 4 "x4" 3/8" Anchors Unistrut 18 Gage Typ of 4 Typ of 2 O Angle Jron J Customer: American Heating, Inc. Seismic Restraints for the roof top Friday's Restaurant 1339 SE Gideon Street Refrigeration equipment. 10145 SW Washington Sq. road Portland, OR 97202 Tigard, OR 97223 • URC -F SERIES , DIMENSIONS (I - CONNECTIONS 3/T i,3/ 15tvis 14111 6 3511/16 _.� 1411/18 I.-- -}-� b— 21 - y I -ma �_� . \ = _r Tr . III HT 't I 1 n URC -7F 197/8 ' URC-6F 18 URC-12F 22 y U 3413/16 lJL1LJUU� 3213/16 UULE 37 `- 21 �A ±� :� Wit♦ 23/4. 3 JL 212 •1 1 ectric Conduit Access Electric Conduit Access � \ 23/4 LI -. i� 13/4 IIq I 3 ,,11 El 13/ Illl ,,1, 3/8 Discharge Line `'i,,, Electrical Conduit '� , , 3/8 Discharge Line II IM -\` 1/4 Liquid Refrigerant •I . 1 Access �‘ I J� 1/4 Liquid 181/8 24 _._-.k Line 181/8 303/8 Refrigerant Line 1/2 Discharge Line N, � \ 181/8 3/8 Liquid Refrigerant \ /� Line Y , _ 371316 Remote Condenser Installation on Roof L _,I,,, 1511/16 • II For Best Perfor- ¢ ` �� I • mance Allow 24" ; ,A A Clearance For Air •a r '° I URC -20F 26 Circulation ..,..g , ` \I F 23/4- 3u�000Lt_ 2 m 1 407/6 -' ,. 1 -' t''' Electrical Conduit Access 1 For Best Perfor- �Y `no = w ' mane the Remote Tow" — .•• ^"" z : : ` ,' '1 Condenser should t , Il' ` Electrical Conduit Ac be not more than I I 1 ` 5/8 Discharge Line 33 feet above the 4 KM Icemaker or no 1 PI 18118 3/8' Liquid Refrigerant Line more than 10 feet 487 --e' 3/8- it. These dis- 14 \...._-_:_______ . � .. Lances are mea- Discharge Line / , .... sured from fitting to fitting. ��P Electrical Conduit :r.. .; 5/8' Discharge Line • cress t ` URC -24F - Liquid Refrigerant Line - , I 1 , 3/8' Liquid Refrigerant ' ` \ ' (11 p Line 1212 111 : 15518 , , h r .. •ice i ' 9 y <.. I „i 212' Dia. Hole in Roof for Tubing. IIIIIIIIIIII IN Seal After Installation to Prevent Leaking. . 4 — of. — 193/4 o. Electrical Connections ELECTRICAL: 115V/60/1 (Connection to Icemaker) Must Meet All Local Codes Discharge URC -24F: 208- 230V/60/1 (Connection to Icemaker) Line *R -404A REFRIGERANT REFRIGERANT CHARGE: All components are pre- charged with quick disconnect fittings i .4::; - f r ii `i, 7 t WARRANTY: s :116114::::-..' ,. e tt 4 - ' eraser -. nnection When Used with KM Series Cuber When Used with F Series Flake( i i' 3 Year Parts & Labor: entire unit 1 Year Parts & Labor: entire unit _' 5 Year Parts: Air - Cooled Condenser 2Yeir Parts & Labor: Air - Cooled Condenser r '-' - ',, gYeaeParts: Air- Cooled Condenser -. t ts:.r- -t?t "; 11i�s Warranties valid in United States, Canada, Puerto Rico, & U.S. Virgin Islands s '. Contact Factory for Warranty in other Countries, Territories, or Possessions. " s 1 ' ..i-.8 e i � `t OPERATING LIMITS: Ambient Temp Range -20 to +122 °F. ti Voltage Range 104 -127V ("187 -253V) + su °t SPECIFICATIONS Icemaker and Storage Bin Sold Separately Ak -cooled Order Tubing Kit Separately Condenser Shipping Pre - Charged Tubing Kits Model Numbe 20' Length 35' Length 55' Length Weight URC-6F R404- 2046 -2 R404- 3546 -2 NA 60 \ ^ (Sold Separately) w • / URC-7F R404- 2046 -2 R404-3546-2 NA 100 // Refer to SPECIFICATIONS Table URC -12F R404- 2068 -2 R404- 3568 -2 R404- 5568 -2 115 to determine appropriate Tub - URC -20F R404-20610 R404-35610 R404- 5568.2 150 ��' O / ing Kit Number for Remote Con - URC -24F R404 -20610 R404 -35610 R404- 5568 -2 210 denser Unit Specified. We reserve the right to change specifications without notice. Printed in U.S A. © H O S H I ZA K I AMERICA INC. . 618 Hwy 74 S., Peachtree City, GA 30269 FAX 1-800-345-1325 TEL 1- 800 - 438 -6087 - www.hoshizaki.com The Power of Reliability.(.