Loading...
Correspondence 9757 . Imo( ►� February 23, 2007 Wyatt Fire Protection 9095 SW Burnham Tigard, OR 97223 RE: FIRE SPRINKLER SYSTEM - REVIEW Project Information Permit: BUP 2007 -00058 Construction Type: II -B Address: 9585 SW Washington Sq. Occupancy Type: M The plan review was performed under the State of Oregon Structural Specialty Code (OSSQ 2004 edition, Oregon Fire Code 2004 edition; and NFPA 13. The submitted plans are approved subject to the following. HANGERS: NFPA sec. 9.2 1). The maximum distance between hangers shall not exceed that specified in Table 9 -2.2. The unsupported length between the end sprinkler and the last hanger on the line shall not be greater than 36 inches for 1" pipe, 48inches for 1 1/4" pipe and 60 inches for 1'h" pipe. The last length of pipe at the end of a feed or cross main shall be provided with a lateral brace per Section 9.3.5.3. The maximum distance between hangers for listed nonmetallic pipe shall be modified as specified in the individual product listings. RESTRAINT OF BRANCH LINES. - Section 9.3.6 2) Restraint is considered a lesser degree of resisting loads than bracing and shall be provided by use of one of the following: (1)A listed sway brace assembly (2)A wraparound U hook satisfying the requirements of 6- 4.5.3, Exception Number 3 (3)No. 12, 440 -lb (200 -kg) wire installed at least 45 degrees from the vertical plane and anchored on both sides of the pipe (4)Other approved means 3) Wire used for restraint shall be located within 2 ft of a hanger. The hanger closest to a wire restraint shall be of a type that resists upward movement of a branch line. The end sprinkler on a line shall be restrained against excessive vertical and lateral movement. Where upward or lateral movement would result in an impact against the building structure, equipment, or finish materials, branch lines shall be restrained at intervals not exceeding 30 ft 4) The unsupported length between the end sprinkler and the last hanger on the line shall not be greater than 36 inches for 1" pipe, 48inches for 1 1/4" pipe and 60 inches for 1 1/2" pipe. - 9.2.3.4 5) The last length of pipe at the end of a feed or cross main shall be provided with a lateral brace per Section 9.3.5.3.4 SPARE SPRINKLERS: - Section 6.2.9 6) The stock of spare sprinklers shall include all types and ratings installed and shall be as follows: a. For systems having less than 300 sprinklers, not fewer than six sprinklers SYSTEM, MAIN DRAINS, or SECTIONAL DRAINS: - Section 8.15.2.4 7) Provisions shall be made to properly drain all parts of the system. Drains shall discharge either to the outside or to a drain connection. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, � 1 TY Nelson, Plans Examiner