Loading...
Permit jr S CITY TIGARD MECHANICAL PERMIT 4 I 4 DEVELOPMENT SERVICES PERMIT #: MEC2002 -00579 DATE ISSUED: 12/16/02 �` 4 J- 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 PARCEL: 1S135BA-00102 SITE ADDRESS: 10100 SW WASHINGTON SQUARE RD A -1 SUBDIVISION: OAKBURG ZONING: C -G BLOCK: LOT: 001 JURISDICTION: TIG CLASS OF WORK: ALT FLOOR FURN: EVAP COOLERS: 1 TYPE OF USE: COM UNIT HEATERS: VENT FANS: OCCUPANCY GRP: A3 VENTS W/O APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: DOMES. INCIN: 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: FIRE DAMPERS ?: 30 - 50 HP: REPAIR UNITS: GAS PRESSURE: 50 + HP: WOODSTOVES: FURN < 100K BTU: AIR HANDLING UNITS CLO DRYERS: FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: > 10000 cfm: GAS OUTLETS: Remarks: Installation of cooler /freezer combo. Project value: $2,000.00 Owner: FEES PPR SQUARE TOO LLC Description Date Amount BY MACERICH COMPANY [MECH] Permit Fee 12/16/02 $72.50 ATTN: JANET FISHER, ASSET MGMT SANTA MONICA, CA 90407 [TAX] 8% StateTax 12/16/02 $5.80 [MECPLN] Plan Rev 12/16/02 $18.12 Phone: Total $96.42 Contractor: TOTAL QUALITY SERVICES 29934 S HWY 213 MOLALLA, OR 97038 REQUIRED INSPECTIONS Phone: 503 Mechanical lnsp Misc. Inspection Reg #: LIC 101372 Final Inspection This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon c Utili uti 'rc�n Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 95 - 001 -0100. l'"o may obtain copies of these rules or direct ques 'ons to OUNC by calling (5 3)246 -6.99. Is ed By: `d i'_,,, - Permittee Signature: / _ % Call (503) 639 -4175 by 7:00 P.M. for inspections needed re next business day Mechanical Permit Application Date received/ /e 0�" Permit no.:pc'� ' J Iia City of Tigard VVV • ty g Project/appl. no.: Expire date: City ojTignrd Address: 13125 SW Hall Blvd, Tigard OR 97223 Date issued: By: Receipt no.: Phone: (503) 639 -4171 Fax: (503) 598 -1960 Case file no.: Payment type: Land use approval: Building permit no.: - TYPE OF PERMIT . ■ ❑ 1 & 2 family dwelling or accessory 0 Commercial/industrial ❑ Multi- family ❑ Tenant improvement ❑ New construction ❑ Addition/alteration/replacement ❑ Other: JOB SITE INFORMATION , • COMMERCIAL VALUATION SCHEDULE Job address: 0 00 SW �,� n PAllk Indicate equipment quantities in boxes below. Indicate the dollar Bldg. no.: Suite no.: . -) value of all mechanical materials, equipment, labor, overhead, Tax map /tax lot/account no.: profit. Value $ 2c0 • C)° • Lot: (Block: I Subdivision: *See checklist for important application information and Project name: jurisdiction's fee schedule for residential permit fee. City /county: I ZIP: 1 & 2 FAMILY DWELLING. PERMIT FEE SCHEDULE Description and location of work on remises: 7a/,ir// to //)'I�'it+l AND COMMERICAL/INDUSTRIAL EQUIPMENT SCHEDULE COOlei - I:�ce - � 7 Fee(ea.) Total Est. date of completion/inspection: Description Qty. Res. only Res. only Tenant improvement or change of use: HVAC: Is existing space heated or conditioned? ❑ Yes ❑ No Air handling unit CFM space insulated? ❑ Yes ❑ No Air conditioning rati fxi ti ngplanrequired) Is existing P Alterati of existi HVAC system . MECHANICAL CONTRACTOR ' • - Boiler /compressors rOf L State boiler permit no.: Business name: "�' 1t1 `� HP Tons BTU /H Address: 2 9 5 f/cv y 2/ 5 Fire/smoke dampers/duct smoke detectors City: yyl o ( 4 I State:dr I ZIP: y 74 ( Heat pump (site plan required) Phone: ?, 5 39 Fax: 2q- 17 E -mail: oficizo (ip z InstalUreplacefurnace / burn BTU /H CCB no.: /4/3/J , rQ / 5 o Including ductwork/vent lin er ❑Yes ❑ No lnstall/replace /relocate heaters - suspended, City /metro lic. no.: • wall, or floor mounted Name (please print): Vent for appliance other than furnace . CONTACT PERSON. Refrigeration: Absorption units BTU/H Name: Chillers s HP Compressors HP Address: g,?q y/ '5,q ,by 213 Evtronmental exhaust and ventilation: City: 04 I State: dr ( ZIP: Q70 3 ' Appliance vent Phone: 3.539 - ; Z 3' Fax: $ ' f,/ 8 , E -mail: gB6t A; , , A ,,L Dryer exhaust OWNER ' ,r .•. Hoods, Type U lUres. kitchen/hazmat hood fire suppression system Name: Exhaust fan with single duct (bath fans) Mailing address: Exhaust system apart from heating or AC City: I State: I ZIP: Fuel piping and distribution (up to 4 outlets) . Type: LPG NG Oil Phone: Fax: E - mail: Fuel piping each additional over 4 outlets Process piping (schematic required) . Number of outlets Name: Other listed appliance or equipment: Address: Decorative fireplace City: I State: I ZIP: Insert - type Phone: ax: E - mail: Woodstoveipelletstove y Other: Applicant's signature: /L. ` ,,, Date: a /7 - Other. Name (print): / f ii ( 9�/ Not an jurisdictions accept credit cards, please call jurisdiction for more information. Permit fee $ O Visa ❑ MasterCard Notice: This permit application Minimum fee $ expires if a permit is not obtained P lan review Credit card number: / / (at _ %) $ Expires within 180 days after it has been State surcharge (8 %) .... $ Name of cardholder as shown on credit card accepted as complete. TOTAL $ Cardholder signature Amount 440 -4617 (6/00/COM) 1 Y ,Y MECHANICAL PERMIT FEES COMMERCIAL FEE SCHEDULE: 1 & 2 FAMILY DWELLING FEE SCHEDULE: TOTAL VALUATION: PERMI -E. Description: Price Total $1.00 to $5,000.00 Minimum ee $72.50 Table 1A Mechanical Code Qty (Ea) Amt $5,001.00 to $10,000.00 $72.50 for th ,000.00 and 1) Furnace to 100,000 BTU • $1.52 for each additional $100.00 or including ducts & vents 14.00 fraction thereof, to and including 2) Furnace 100,000 BTU+ $10,000.00. including ducts & vents 17.40 $10,001.00 to $25,000.00 $148.50 for the first $10,000.00 and 3) Floor Furnace $1.54 for each additional $100.00 or including vent 14.00 fraction thereof, to and including 4) Suspended heater, wall heater $25,000.00. or floor mounted heater 14.00 $25,001.00 to $50,000.00 $379.50 for the first $25,000.00 and 5) Vent not included in appliance permit 6.80 $1.45 for each additional $100.00 or fraction thereof, to and including 6) Repair units $50,000.00. 12.15 $50,001.00 and up $742.00 for the first $50,000.00 and Check all that apply: Boiler Heat Air $1.20 for each additional $100.00 or For items 7 -11, see or Pump Cond fraction thereof. footnotes below. Comp Minimum Permit Fee $72.50 SUBTOTAL: $ 7) <3HP; absorb unit to 100K BTU 14.00 8% State Surcharge $ 8) 3 -15 HP; absorb 25.60 unit 100k to 500k BTU 25% Plan Review Fee (of subtotal) $ 9) 15-30 HP; absorb unit .5 -1 mil BTU 35.00 Required for ALL commercial permits only 10) 30-50 HP; absorb TOTAL COMMERCIAL PERMIT FEE: $ unit 1 -1.75 mil BTU 52.20 11) >50HP; absorb unit >1.75 mil BTU 87.20 ASSUMED VALUATIONS PER APPLIANCE: 12) Air handling unit to 10,000 CFM 10.00 Value Total 13) Air handling unit 10,000 CFM+ Description: Qty (Ea) Amount 17.20 Furnace to 100,000 BTU, including 955 14) Non - portable evaporate cooler ducts & vents 10.00 Furnace > 100,000 BTU including 1,170 15) Vent fan connected to a single duct ducts & vents 6.80 Floor furnace including vent 955 16) Ventilation system not included in Suspended heater, wall heater or 955 appliance permit 10.00 floor mounted heater 17) Hood served by mechanical exhaust Vent not included in appliance 445 10.00 permit 805 18) Domestic incinerators 17.40 Repair units < 3 hp; absorb. unit, 955 19) Commercial or industrial type incinerator to 100k BTU 69.95 3 -15 hp; absorb. unit, 1,700 20) Other units, including wood stoves 101k to 500k BTU 10.00 15-30 hp; absorb. unit, 501k to 1 2,310 21) Gas piping one to four outlets mil. BTU 5.40 30 -50 hp; absorb. unit, 3,400 22) More than 4 -per outlet (each) • 1 -1.75 mil. BTU 1.00 >50 hp; absorb. unit, 5,725 Minimum Permit Fee $72.50 SUBTOTAL: 7 � ,mi >1.75 mil. BTU $ SD Air handling unit to 10,000 cfm 656 8% State Surcharge $ Air handling unit >10,000 cfm 1,170 Non - portable evaporate cooler 656 TOTAL RESIDENTIAL PERMIT FEE: $ Vent fan connected to a single duct 446 Vent system not included in 656 appliance permit Hood served by mechanical exhaust 656 Other Inspections and Fees: 1,170 1. Inspections outside of normal business hours (minimum charge - two hours) Domestic incinerator $62.50 per hour. Commercial or industrial incinerator 4,590 2. Inspections for which no fee is specifically indicated (minimum charge - half hour) Other unit, including wood stoves, 656 $62.50 per hour inserts, etc. 3. Additional plan review required by changes, additions or revisions to plans (minimum Gas piping 1 - 4 outlets 360 charge -one -half hour) $62.50 per hour Each additional outlet 63 *State Contractor Boiler Certification required for units >200k BTU. TOTAL COMMERCIAL $ * `Residential NC requires site plan showing placement of unit. VALUATION: All New Commercial Buildings require 2 sets of plans. is \dsts\forms\mech- fees.doc 02/11 /02 1 o / 0 Form 2a °Project Name: RED ROBIN Page: 1 G 2.00 — 6060 3 -5 SUMMARY Project 1. Project Name RED ROBIN RESTAURANT 2. Project Address 10100 SW WASHINGTON SQUARE RD Cn 3. City/Town TIGARD 5. County WASHINGTON C 4. Building, Gross Area (ft 7,234 6. No. of Floors 1 3 B CO Chapter Type ID Description Attached -1 Attached Building Envelope Form 3a Building Envelope - General Ii Forms and 3b Prescriptive Path - Zone 1 El Worksheets 3c Prescriptive Path - Zone 2 ❑ Check boxes to 3d Simplified Trade -off (Use CodeComp software) ❑ indicate attached forms and Worksheet 3a . Wall U- factors ❑ worksheets. 3b Roof U- factors ❑ 3c Floor U- factors ❑ Systems Form 4a Systems - General p 4b Complex Systems p IC1 0 PR Opt Worksheet 4a Unitary Air Conditioners - Air Cooled eN ( " 1694E 4b Unitary Air Conditioners - Water Cooled 4c Unitary Heat Pump - Air Cooled ❑ 4d Unitary Heat Pump - Water & Ground Cooled ❑ 4e Unitary AC - Evaporatively Cooled ❑ i ' y �MN 4f Packaged Terminal Air Conditioner - Air Cooled ❑ '; L. * 6:t o �k ❑ 4g Packaged Terminal Heat Pump - Air Cooled ® 4r ��' 4h Water Chilling Packages - Water & Air Cooled ❑ yROY S 4i Boiler - Gas -fired & Oil -fired ❑ 4j Furnaces and Unit Heaters - Gas -fired & Oil -fired p Lighting Form 5a Lighting - General El 5b Interior Lighting Power - Occupancy Method LI 5c Interior Lighting Power - Space -by -Space Method ❑ Worksheet 5a Interior Lighting Power U 5b Lighting Schedule 5c Interior Control Credits ❑ Applicant 7. Name 10. Telephone . 8. Company 11. Date 9. Signature Attached No. of Pages Description of Document Documen- tation 3 ROOFTOP UNIT INFORMATION 3 MAKEUP AIR UNIT INFORMATION 4 LIGHT BULB INFORMATION (10/00) Forms 2 -1 Form 3a Project Name: RED ROBIN Page: 2 BUILDING ENVELOPE - GENERAL Check all boxes 1. Exceptions (Section 1312) that apply. ❑ No Envelope Components. The building plans do not call for new or altered building envelope components, e.g., walls, floors or roof /ceilings. Li A Non - conditioned Building. The proposed structure has no spaces heated or cooled by an HVAC system. Exceptions ❑ Exception. All new or altered building envelope components do not comply with the require- ments of Sec. 1312, but qualify for exception # . Portions of the building that qualify: Discussion of . The plans /specs qualifying excep s how compliance with this requirement on the following a es: lions on page 3 -g. P q 9 P 9 2. Air Leakage (Section 1312.1.1) ❑ Complies. Plans require that penetrations in the building envelope are sealed and that windows and doors are caulked, gasketed or weatherstripped. The plans /specs show compliance with this m requirement on the following pages : — __ - - - -_ SPECIFICATION SECTION 07920 CD 3. Suspended Ceiling (Section 1312.1.2.1) 0 0 Complies. The building plans do not call for a suspended ceiling separating conditioned spaces CD from unconditioned spaces. No exceptions are permitted. 4. Recessed Light Fixtures (Section 1312.1.2.2) ❑ Complies. The building plans do not show recessed light fixtures installed in ceilings separating conditioned spaces from unconditioned spaces. Exceptions 01 Exception. The building plans require that fixtures installed in direct contact with insulation be insulation coverage (IC) rated. The plans /specs show compliance with this exception on: Discussion of -------- - - - - -- -- - -- qualifying excep- tions on page 3 -10. 5. Moisture Control (Section 1312.1.4) ❑ Complies. A one -perm vapor retarder is installed on the warm side (in winter) of all exterior floors, walls and ceilings, and a ground cover is installed in the crawl space for both new and existing buildings where insulation is installed. The plans /specs show compliance with this requirement on: ___ -- SPECIFICATION SECTION 07211, DRAWING A4.0 - - -_ Exceptions Li Exception. All new or altered building envelope components do not comply with the vapor retarder requirements of the code, but qualify for an exception. Note applicable code exception. Discussion of qualifying excep Section 1312.1.4, Exception ____ . Portions of the building that qualify: ____________ tions on page 3 -11. 6. Climate Zones Climate Zone 1 - A building site is in Climate Zone 1 if its elevation is less than 3,000 feet above sea level Zones and it is in one of the following counties: Benton, Columbia, Clackamas, Clatsop, Coos, Curry, Zone 1 Buildings: Douglas, Jackson, Josephine, Lane, Lincoln, Linn, Marion, Multnomah, Polk, Tillamook, Yamhill, Complete Form 3b. or Washington. Zone 2 Buildings: ❑ Zone 2 - Building sites not in Zone 1 are in Zone 2. Complete Form 3c. (10 /00) Forms & Worksheets 3 - i e_ N Glazing + b o Fraction - 35 X 100 = 23.4 Official Use On G Total Building Window Total Building Exterior Building Glazing Calculation Area (total rough frame ft Wall Area (gross ft Fraction cr Windows Thermal Performance' (U Factor) Shading Coefficient (SC) Official Use Only n Windows 0.43 0.51 Walls Wall / Insulation Type R - Value Insulation only U- Factor' O Use Only EXTERIOR FRAME WALL WITH BATT INSULATION 19 I or or 4 or or Below- Below - Grade Walls R - Value Insulation Only U - Factor (Max. 0.11) Official Use Only Grade (Min. R -7.5) 1 '7 1 Walls NONE I or I W D i I 3 Code I Max. I Wall Requirements I Window Requirements I a ti ReQ amts. Glazing Wall / Insulation Type M in. R -Value Max. Shading Z Po Fraction Max. U- Factor Max. U- Factor Discussion of w/inteqral loose fill insulation NA 0.30 Insulation o Coefficient m B m CMU Masonry', this section of Up to 15% 0.54 0.57 7 o the form on Ma or concrete', w /cont. exterior insulation 1.4 or 0.30 t u) pages 3 -12 CMU Masonry', w/ integral rigid fill insulation NA 0.21 m Masonry w/ interior insulation 11 o 0.13 N co asonry or concrete', nsu through 3 -14 0 CD Up to 30% Masonry or concrete', w /cont. exterior insulation 2.8 or 0.21 0.54 0.57 in Frame (wood or metal framing) 13 or 0.13 co Other (provide short description) 13 or 0.13 I CMU Masonry', w/ integral rigid fill insulation NA 0.21 Masonry or concrete', w/ interior insulation 11 or 0.13 I I I Up to 40% Masonry or concrete', w /cont. exterior insulation 2.8 or 0.21 0.37 0.35 Frame wood or metal framin 13 or 0.13 Other (provide short description) I 13 I or i 0.13 1 Enter "overall" U- factor for window assembly or write -in DTS (deemed to satisfy). See "Window Requirements" in table above for specific DTS requirements. Q_R .! G G N For multiple types of glass and U- factors, enter the highest U- factor of the group. Maximum window U- factor is for entire window assembly per ASHRAE 1997 Fundamentals Handbook or NFRC Thermal Performance Rating Certification and Labeling Program. 2 Enter "center -of - class" shading coefficient (SC) for glass orwrite -in DTS (deemed to satisfy). See "Window Requirements" in table above for specific DTS requirements. Solar Heat Gain Coefficient (overall window SHGC per NFRC) can be converted to SC using this equation: SHGC + 0.87 = SC. For multiple types of ..li glass and shading coefficients, enter the highest shading coeent of the group. s Submit Worksheet 3a for each calculated assembly U- factor. ffici la. M grl ° The Simplified Trade -off Approach must be used if glazing fraction exceeds allowable percentages. CO 5 Minimum weight of masonry and concrete walls = 50 lb/ft of wall face area. _ ; r ., 4, ®j.,.a 6 All cores to be filled. At least 50 percent of cores must be filled with vermiculite or equivalent insulation. IN E N E R► G Y ' Prescriptive "deemed to satisfy" (DTS) U- factor description is double glazed, 0.5 -inch airspace, low- emissivity (e) coating no greater than 0.4 and aluminum w frame. DTS shading coefficient descnption is a tinted outboard pane of glass. Ms 0 C 0 D E 8 All cores except bond beams must contain rigid insulation inserts approved for use in reinforced masonry. O OC: T 2 0 01 9 Batt insulation installed in metal or wood frame walls shall be insulated to full depth of cavity, up to 6 inches in depth. N 10 Prescriptive "deemed to satisfy" (DTS) U- factor description is double glazed, 0.5 -inch argon filled space, low.e coating no greater than 0.05 & thermal break _ frame. DTS shading coefficient description is 0.25 -inch thick glass, low-e coating on surface 2, no greater than 0.05 S tinted outboard pane. ,; Form 4a Project Name: RED ROBIN Page: 4 SYSTEMS - GENERAL Exceptions 1. Exceptions (Section 1313) Discussion of ❑ No HVAC. The building plans do not call for an HVAC system. Skip to Item 12 below. qualifying excep ❑ Exception. The building or part of the building qualifies for an exception from HVAC code tions on page 4 - 14 requirements. The applicable code exception is Section 1313, Exception __ . Portions of the building that qualify: See page 4 - 14 fora 2. Simple or Complex Systems (Section 1313.2 or 1313.3) discussion of simple ❑ Simple System. The planned HVAC system qualifies as a Simple System. If true, complete this vs. complex form (4a) and equipment efficiency worksheets as required. Form 4b is not required. systems. la Complex System. The planned HVAC system is a Complex System. Complete this form (4a), Form 4b and equipment efficiency worksheets as required. Exceptions 3. Economizer Cooling (Section 1313.1.2) Complex systems ID No Cooling. The building plans do not call for a new fan system with mechanical cooling. may claim the same ❑ Complies. The new fan system has an air economizer capable of modulating outside - air and exceptions allowed return -air dampers to provide up to 85 percent of the design supply air as outdoor air. for simple systems, plus three excep ❑ Exception — Simple Systems. The new fan system qualifies for an exception. The applicable tions allowed in code exception is Section 1313.1.2, Exception____, or Section 1313.2.1. Portions of the Section 1313.1.2. building that qualify: See page 4 - 15 for a discussion of these Li Exception — Complex Systems. The new fan system qualifies for an exception. The applicable exceptions, code exception is Section 1313.1.2, Exception ___, or 1313.3.1, Exception ____. Portions of the building that qualify: _ 4. Economizer Cooling - Overpressurizing (Section 1313.1.2) ❑ No Economizer. The building plans do not call for a new fan system with an economizer. i Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will exhaust the extra air introduced by the economizer, and the economizer system is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the load. 5. System and Zone Controls (Sec. 1313.1.3.1 as 1313.1.3.2) Ul Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zone. ❑ Exception. The new HVAC system qualifies for an exception from the zone control require - Exceptions ments. The applicable code exception is Section 1313.1.3.2, Exception 1 and 2. Portions of the Discussion of building that qualify: qualifying excep- tions on page 4 -16. 6, Control Capabilities (Sec. 1313.1.3.2.1) l:l Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1313.1.3.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Li Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1313.1.3.2.1, Exception___ . (10 /00) Forms & Worksheets 4 -1 Form 4a (cont.) Project Name: RED ROBIN Page: 5 SYSTEMS - GENERAL 7. Off -hour Controls - HVAC Systems (Section 1313.1.3.3) • Complies. All new HVAC systems are capable of automatic setback or shutdown during periods of non -use or alternate use of the space served by the system. ❑ Exception. Equipment has full load heating demands of 2 kW (6,826 Btu /hr) or less and is controlled by a readily accessible manual off -hour control. 8. Off -hour Controls - Supply and Exhaust Systems (1313.1.3.3) ❑ Complies. Plans require that outdoor air supply and exhaust systems have a means of auto- matic (either motorized or gravity damper) volume shutoff or reduction during periods of non -use or alternate use of the space served by the system. ❑ Exception. The building qualifies for an exception to the requirement for automatic shutoff or reduction. The applicable code exception is Section 1313.1.3.3, Exception _. 9. Heat Pump Controls (Section 1313.1.3.4) 'Li No Heat Pump. The plans /specs do not call for a new heat pump. ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled as required in Section 1313.1.3.4. 10. Equipment Performance (Section 1313.1.4) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment or heat - operated cooling equipment. ❑ Complies. All new HVAC equipment has efficiencies not less than those required by the code. The following equipment efficiency worksheets are attached: - -- 4A, 4J — _ - -_ -- V 11. Duct Insulation (Section 1313.2.2 & 1313.3.2) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. U Simple System: Complies. The plans and specifications call for a Simple System, and all exterior supply /return air - handling ducts and plenums and all outside air ducts are insulated as required by Section 1313.2.2. ❑ Complex System: Complies. The building plans /specs call for a Complex System, and all air - handling ducts and plenums are insulated as required by Sec. 1313.3.2. 12. Piping Insulation (Section 1314) Exceptions ❑ No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. Discussion of O Complies. All new piping serving a heating or cooling system or part of a circulating excep P� P�P 9 9 g 9 Y P 9 service tions on page 4 - 18 water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for the following exception: Section 1314, Exception —_ . 13. Service Water Heating (Section 1315) REUSE EXISTING WATER HEATING SYSTEM ❑ No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks, service hot water distribution systems, swimming pools or spas. Exceptions ❑ Complies. All new water heaters, hot water storage tanks, service hot water distribution sys- Discussion of tems, swimming pools or spas comply with the requirements of the Code. qualifying excep ❑ Exception. The applicable code exception is Section____ ___ , Exception __ . Portions of tions on page 4 - 18 the building that qualify: 4 - Forms & Worksheets (10/00) Form 4b Project Name: RED ROBIN Page: 6 COMPLEX HVAC SYSTEMS 1. Simple or Complex System (Sections 1313.2 & 1313.3) Note: This form is required for complex systems only. If your plans qualify as a simple system as defined by the code, you can skip this form. 2. Simultaneous Heating and Cooling (Section 1313.3.3.1) ❑ No Cooling. The building plans and specifications call for a heating -only system. • Complies. Temperature and humidity controls are capable of operating in sequence the supply of cooling and heating energy to the zone as required by the code. Controls for this purpose are Exceptions detailed in the plans and specifications on: SHEET MEP, SECTION 15500 ❑ Exception. The building or part of the building qualifies for an exception from the code. The Discussion of applicable code exception is Section 1313.3.3.1, Exception:___ . Portions of the building that qualifying excep- qualify: Lions on page 4 -20. _________–_--_---__--__—_------ 3. Humidity Controls (Section 1313.3.3.2) ❑ No Moisture Added to Building. The building plans do not call for a means to add moisture to maintain specific humidity levels. ❑ Complies. All new humidity control systems are equipped with a humidistat as required by code. 4. Air Transport Energy (Section 1313.3.4.2 & Table 13 -L) Air ❑ Complies. The energy demand of all HVAC fan systems meets code requirements. Complete Transport the form below. Energy ❑ Exception. The applicable code exception is Section 1313.3.4.2, Exception: 1_ . Portions of the See Table 134, Fan VAV or Max page 4 -24, for System Constant Design Motor Allowed Where noted in maximum horse- ID Description Volume Airflow (cfm) HP HP plans /specs power allowed. C) building that qualify: 5. Motor Efficiency (Section 1313.3.5 & Table 13 -M) ❑ Not Regulated. There are no NEMA Design A & B squirrel cage, T -frame induction, permanently wired polyphase motors of one horsepower or more which serve built -up HVAC systems (regu- lated motors). ❑ Complies. The efficiency of all regulated motors meets code requirements. Exceptions ❑ Exception. The applicable code exception is Section 1313.3.4.2, Exception:___ . Portions of the Discussion of building that qualify: qualifying excep- tions on page 4 -22. 6, Variable Speed Drives (Section 1313.3.5.1) ❑ Not Regulated. The building plans and specifications do not call for fan and pump motors 25 horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 25 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. (10/00) Forms & Worksheets 4 - Worksheet 4a Project Name: RED ROBIN Page: 7 UNITARY AIR CONDITIONER - AIR COOLED Equipment Proposed Cooling Proposed Seasonal or Part Discussion of Equip. Capacity Steady State Ref Model Designation equipment ratings ID Load Efficiency and equipment (Btu /h) Efficiency (EER) (SEER or IPLV) Line definitions on page 4 - RTU -1 LENNOX LGA210H 219,275 11.2 12.3 3 RTU -2 LENNOX LGA210H 222,600 11.2 12.3 3 RTU -3 LENNOX LGA180H 178,500 11.5 13.3 3 Required Indicate source of information Documenta- ARI Unitary Directory, Section AC, page: tion ARI Applied Products Directory, Section ULE, page: X Product data (Attach data furnished by the equipment supplier, i.e., "cut sheets") Highlight or otherwise indicate equipment selected on documentation provided Code Cooling Capacity (Btu/h) Minimum Rating Required Equipment Type Ref. Q Efficiencies Equal to or But less than Steady State Seasonal or Line greater than Part Load This schedule of Single Package 0 65,000 na 9.7 SEER = equipment efficiencies without a 65,000 135,000 10.3 EER 10.6 IPLV was reformatted from heating section 135,000 240,000 9.7 EER 9.9 IPLV ( the code, Table 13 or with electric 240,000 760,000 9.5 EER 9.7 IPLV resistance heat 760,000 - 9.2 EER 9.4 IPLV 0 65,000 na 10.0 SEER Split System without a 65,000 135,000 10.3 EER 10.6 IPLV heating section 135,000 240,000 9.7EER 9.9 IPLV (2) or with electric 240, 000 760, 000 9.5 EER 9.7 IPLV resistance heat 9.2 EER 9.4 IPLV 760,000 - Single Package 0 65,000 na 9.7 SEER with a heating 65,000 135,000 10.1 EER 10.4 IPLV section other 135,000 240,000 9.5 EER 9.7 IPLV (3) C) R E C- 0 N than electric 240,000 760,000 9.3 EER 9.5 IPLV -� ivies resistance heat - 760,000 9.0 EER 9.2 IPLV IJ 0 65,000 na 10.0 SEER Split System with a Heating 65,000 135,000 10.1 EER 10.4 IPLV �' �V��„ `" section other 135,000 240,000 9.5 EER 9.7 IPLV (4) 1, . than electric 161r h l resistance heat 240,000 760,000 9.3 EER 9.5 IPLV pen- r.id�rsiioi 760,000 - 9.0 EER 9.21PLV FNFRGY FORMS Condensing ng Unit 135,000 - 10.1 EER 11.2 IPLV (5) OCT 2000 4-4 Forms & Worksheets (10/00) ,, Worksheet 4j Project Name: RED ROBIN Page: 8 FURNACES & UNIT HEATERS - GAS & OIL -FIRED Equipment Heating Proposed Proposed Proposed Equip. Capacity Minimum Thermal Combust. Ref. Discussion of Model Designation equipment ratings ID (Btu /h) AFUE Efficiency Efficiency Line and equipment definitions on page 4 -19 MAU -1 CAPTIVE -AIRE NHMUA1 125,000 — — 100% 1 Required Indicate source of information Documents- GAMA Consumer Directory, page: tion x Product data (Attach data furnished by the equipment supplier, i.e., "cut sheets") Highlight or otherwise indicate equipment selected on documentation provided D Code Required Heating Capacity q (Btu /h) Minimum Rating Efficiencies Ref. Equipment Type Season. Line This schedule of Equal to or But less Thermal Combust. equipment efficiencies greater than than Rating Efficiency Efficiency was reformatted from AFUE the code, Table 13 -1 Warm Air Furnaces, 0 225,000 78% 80% na (1) Gas -Fired 225,000 - na na 80% 01? F, G O N Warm Air Furnaces, 0 225,000 78% 80% na (2) Oil -Fired 225,000 - na na 81% 1r 1 i, Warm Air Duct ifs Furnaces, Gas -Fired 0 - na na 80% ( r Na . mai Warm Air Unit 0 - na na 80% ( d, r7 Heaters, Gas -Fired F. NF, T? Y FORMS Warm Air Unit 0 - na na 80% ( OCT 2 0 0 0 Heaters, Oil Fired (10/00) Forms & Worksheets 4 - Form 5a Project Name: RED ROBIN Page: 15 LIGHTING - GENERAL 1. Interior Exceptions (Section 1316.1) ❑ No Interior Lighting. The building plans do not call for new or altered interior lighting. Skip to Item 4, Exterior Building Lighting — General, below. Exceptions ❑ Exception. The building or part of the building qualifies for an exception from code lighting Discussion of requirements. The applicable code exception is Section _, Exception(s) . qualifying excep- Portions of the building that qualify: ____ ______________ ------------- tions on page 5-7. -- _-- - -___ • 2. Local Shut -off Controls (Section 1316.1.2.1,1) ▪ Complies. At least one local shut -off lighting control for every 2,000 square feet of lighted floor area and for all spaces enclosed by walls or ceiling height partitions. This control(s) is detailed in Exceptions the building plans on drawing number E4.0 Discussion of U Exception. The building or part of the building qualifies for an exception. The applicable code qualifying excep- exception is Section 1316.1.2.1,1, Exception . Portions of the building that qualify: _ _ Lions on page 5 -8. 3. Office Controls (Section 1316.1.2.1,2) ❑ Not an Office Occupancy over 2,000 square feet. ❑ Complies. All interior lighting systems are equipped with a separate automatic control to shut off Exceptions the lighting and local override switching. These control(s) are detailed in the building plans on drawing number_ Discussion of qualifying excep- ❑ Exception. The building or part of the building qualifies for an exception. The applicable code Lions on page 5-9. exception is Section 1316.1.2.1,2, Exception ____ . Portions of the building that qualify: Definition EXTERIOR 4. Exterior Building Lighting - General BUILDING ❑ No Exterior Building Lighting. Skip the rest of this form. LIGHTING is lighting directed to ❑ Complies. Complete items 5 and 6 below. illuminate the exterior of the 5. Exterior Building Lighting Controls (Section 1316.1.2.2 building and g g g onro ( 1316.1.2.2) adjacent walkways • ❑ Complies. The building plans require that all exterior building lighting is equipped with automatic and loading areas controls described in Sec. 1316.1.2.2. These controls are detailed in the building plans on with or without drawing number E2.2 canopies. - - - -- ❑ Exception. The exterior building lighting is intended for 24 -hour continuous use. r 6. Exterior Building Lighting Power (Section 1316.2.2) ❑ Complies. The plans do not call for incandescent lamps greater than 10 Watts for use in exterior building lighting. ❑ Exception. The building plans indicate luminaires with incandescent lamps greater than 10 � . Watts, but they are 5 percent or less of the total installed exterior lamps. Total number of exterior lights _ Total number of exterior incandescent lights __ _ __. (10 /00) Forms & Worksheets 5 - Form 5b Project Name: RED ROBIN Page: 16 • INTERIOR LIGHTING POWER - OCCUPANCY METHOD (a) (b) (c) (d) (e) (f) (9) Lighting Max Budget Power Lighting Power Floor Density Budget Group Occupancy Use Area (ft (W /ft ((c -d) x e) + f Retail or If area is less than 2,000 ft enter Merchandise area in (c), this row 0 3.4 0 (Group M only) If area is between 2,000 and 6,000 M ft enter area in (c), this row 2,000 2.5 6,800 If area exceeds 6,000 ft enter 6,000 1.7 16,800 area in (c), this row (a) (b) (c) (d) (e) (f) (9) Other Occupancy/ Max Use Types Floor Power Lighting Power See page 5 -11 for Area Density Budget instructions. Group Occupancy Use Ceiling Height (ft (W /ft d x e under 15 ft 7,234 1.50 10,851 A RESTAURANTS 15 ft or more under 15 ft 15 ft or more under 15 ft 15 ft or more under 15 ft 15 ft or more 1. Total Interior Lighting Power Budget (Watts). Add amounts in column (g) 10,851 Track 2. Total length of track lighting (ft) 0 Lighting 3. Multiply line 2 by 37.5 Watts /ft 0 4. Total amperage of circuit breaker(s) serving track lighting (amps) 0 5. Voltage of circuit breaker serving track lighting (volts) 0 6. Wattage of circuit breaker serving track lighting (multiply line 4 by line 5) 0 7. Track Lighting Power (enter smaller of line 3 or line 6) 0 Building's 8. Track Lighting Power from line 7 0 Lighting g g 9. Total Interior Lighting Power from Worksheet 5b + 10,471 J Power 10. Total Control Credit from Worksheet 5c - 0 Total Adjusted Lighting Power (Watts). 11. Add lines 8 and 9, subtract line 10 = 10,471 12. Does design meet budget? Enter "YES" if line 11 is not greater than line 1. Otherwise redesign. YES I 5 -2 Forms & Worksheets (10 /00) • Worksheet 5a Project Name: RED ROBIN Page: 17 LIGHTING SCHEDULE Lum. ID is the (a) (b) (c) (d) (e) (f) identification number or letter used in your plans Lamp' Ballast Luminaire or specifications 'Enter the number Lum. Power and type of lamps in ID Luminaire Description No. Description No. Description (Watts) 5b the luminaire. See Table 5b for typical LFO RECESSED CAN 1 lamp codes. 2 Enter the number LF1A 2 FT X 4 FT TROFFER 3 F32T8 1 ELECT 93 X and type of ballasts in the luminaire. For LF1 B 2 FT X 4 FT TROFFER 3 F32T8 1 ELECT 93 X fluorescent and high- intensity LF1C 2 FT X 4 FT TROFFER 3 F32T8 1 ELECT 93 X discharge lamps, typical ballast LF3 4 FT FLUORESCENT STRIP 2 F32T8 1 ELECT 62 X abbreviations are: MAG STD for LF4 RECESSED CAN 1 150W A21 0 NONE 150 Magnetic Standard •MAG EE for LF7 RECESSED CAN 1 50W PAR30 0 NONE 50 Energy Efficient Magnetic LF11 PENDANT LIGHT 1 50W PAR20 0 NONE 50 •ELECT for Electronic LF13 MONOPOINT LIGHT 1 35W PAR20 0 NONE 35 See Table 5b for other ballast LF14 MONOPOINT LIGHT 1 35W PAR20 0 NONE 35 abbreviations. LF15 PENDANT 1 35W PAR20 0 NONE 35 LF16 PENDANT 1 35W PAR20 0 NONE 35 LF17 PENDANT 1 35W PAR20 0 NONE 35 LF18 PENDANT 1 35W PAR20 0 NONE 35 LF19 RECESSED CAN 1 50W PAR20 0 NONE 50 LF31 2 FT X 4 FT TROFFER 3 F32T8 1 . ELECT 93 X CD C J 5-4 Forms & Worksheets (10/00) Worksheet 5b Project Name: RED ROBIN Page: 18 INTERIOR LIGHTING POWER 'Enter the quantity (a) (b) (c) (d) (e) (f) for every non- exempt luminaire. Luminaire Lighting Do not consider Room or Luminaire Quantity of Power Power track lighting on this worksheet. Track Sheet No. Room or Plans Designation ID Luminaires' (Watts) (d) x (e) lighting is accounted for on Form 5b. 101 ENTRY LF19 2 50 100 104 DINING LFO 6 10 60 104 DINING LF4 3 150 450 104 DINING LF11 15 50 750 104 DINING LF13 38 35 1330 104 DINING LF14 35 35 1225 104 DINING LF15 11 35 385 104 DINING LF16 9 35 315 104 DINING LF17 9 35 315 104 DINING LF18 9 35 315 104 DINING LF19 26 50 1300 104 DINING LF31 3 93 279 105 VESTIBULE LF7 1 50 50 105 VESTIBULE LF19 2 50 100 106 MENS LF7 3 50 150 106 MENS LF19 5 50 250 107 WOMENS LF7 3 50 150 107 WOMENS LF19 5 50 250 111 TEAM RESTROOM LF1C 1 93 93 r 113 COOK LINE LF1A 17 93 1581 CC• e-* 113 COOK LINE LF1B 8 93 744 117 OFFICE LF1A 1 93 93 co 118 TRASH ROOM LF3 2 62 124 120 MECH. ROOM LF3 1 62 62 2 Additional pages may be necessary if building has more 1. Page Total. 10,471 rooms than there Total the amounts in column (f). Add the sum of all pages on Form 5b, line 8. are lines on this form. (10 /00) Forms & Worksheets 5 -5 CITY OF TIGARD 24 -Hour BUILDING Inspection Line: _03)639-4175 INSPECTION DIVISION Business Line: (503) 639 -4171 MST BUP • Received Date Requested ° Z _ "I AM PM BUP Location 0 //a ' 0,4 tap Suite 404/ MEC aid ZO — 5 1 1 /f Contact Person Ph ( ) 9 r 4 I o?DDa - a 79 Contractor Ph r°� �) Z/62 3 l� SWR BUILDING Tenant/Owner ELC Footing Foundation ELC Access: Ftg Drain ELR Crawl Drain Slab Inspection Notes: SIT Post & Beam Shear Anchors Ext Sheath/Shear Int Sheath/Shear Framing Insulation Drywall Nailing Fire wall / 1-)AtiP Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Other: Final PASS PART FAIL PLUMBING Post & Beam Under Slab Rough -In Water Service \ — Sanitary Sewer Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: Final PASS PART FAIL 4 A ANICA Post & Beam • Rough -In Gas Line Smoke Dampers IMP tWP PART FAIL EL TRICAL Service • Rough -In UG /Slab Low Voltage Fire Alarm • Final Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE Please call for reinspection RE: 111 Unable to inspect - no access Fire Supply Line ADA '�( J 1 � \ ' ,� s ; � Approach/Sidewalk Date Inspector Ext Other: ; r Final DO NOT REMOVE this Inspection record from the job site. PASS PART FAIL CITY OF TIGAR® 24 -Hour ' BUILDING Inspection Line: (503) 639 -4175 Z00 2 - co I'® ins INSPECTION DIVISION " Business Line: • (503) 639 -4171 BUP 2UU Z — b S z-7 Received bate Requested equested / ° 3 \� AM PM BUP .Location /0/0 O l k Q RD Suite M a7 `(1 Contact Person Ph ( q)s "L(1 g- 3 ( Cl (P N 1 `2.6 d 2 - 0° Contractor Ph ( SWR Tenant/Owner ELC Foundation ELC Access: Ftg Drain ELR Crawl Drain Slab Inspection Notes: SIT Post & Beam Shear Anchors Ext Sheath/Shear Int Sheath/Shear Framing Insulation Drywall Nailing Firewall Fire Sprinkler Fire Alarm s 'd Ceilin Roo Other: F •.6_111i1 PART FAIL I BING Post & Beam Under Slab Rough -In Water Service Sanitary Sewer - Rain Drains Catch Basin / Manhole /2-G 74 /& 44' tV C�'C Storm Drain I Shower Pan Other: Final - PASS PART FAIL MECHANICAL Post pU -•r � c 9 � < u h -In Gas Line Smoke Dampers Fi � �,E'� PART FAIL CTRICAL Service Rough -In UG /Slab Low Voltage Fire Alarm Final Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE ❑ Please call for reinspection RE: ❑ Unable to inspect — no access Fire Supply Line ADA �f Approach/Sidewalk Date / / 3 Ins pector '7 Ext Other: Final - DO NOT REMOVE this inspection record from the job site. PASS PART FAIL