Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
FE 0 Ob FIRE ALARM SYSTEM RECORD OF COMPLETION • To be completed by the system installation contractor at the time of system acceptance and approval. 1. PROTECTED PROPERTY INFORMATION Name of property: L ; ✓1 C 01 v Ge✓ 4 ( # Address: 1 Z- (J 0 S L✓ 6 b,Ar /2d , T i y q ro 0 l? 9 7 2 23 Description of property: Occupancy type: - Name of property representative: S14ore/A <4 2 eA/t y Se r✓%ce; Address: 10710 .5 t,../ &Tft°trlbtAry , 2 / , Por1 /4) 02 9 - 7273 Phone: Fax: / E -mail: Authority having jurisdiction over this property: Phone: Fax: E -mail: 2. FIRE ALARM SYSTEM INSTALLATION, SERVICE, AND TESTING INFORMATION Installation contractor for this equipment: E /e c - / ri GA I C ovKrrtic,fiv Address: 7 - ) 2 - 1 Al"' 7- 4GOA .. 5*. pori sec / og 9 7 Z IC) Phone: Fax: E -mail: Service organization for this equipment: 5i ✓✓ipleis Grinn e / Address: 6 30S" SL✓ S4, L-k e 65 we 0 o iT 970 3.1 Phone: 5 63 ! aft-) Fax: E -mail: r Location of as -built drawings: S, {'C Location of historical test reports: S. 4e Location of system operation and maintenance manuals: S, }-e A contract for test and inspection in accordance with NFPA standards is in effect as of . Contracted testing company: Address: Phone: Fax: E -mail: Contract expires: Contract number: Frequency of routine inspections: 3. TYPE OF FIRE ALARM SYSTEM OR SERVICE NFPA 72 Chapter Reference of System Type: C Name of organization receiving alarm signals with phone numbers (if applicable): Alarm: A oltlG ✓t a e P Phone: Supervisory: `' Phone: Trouble: ' t Phone: Entity to which alarms are retransmitted: ✓✓ /,4_ Phone: Method of retransmission of alarms to that organization or location: Reprinted with permission from NFPA 72, National Fire Alarm Code®, Copyright ©2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety. © 2007 National Fire Protection Association SG24 -2 -014 Rev. (10/07) (p.1 of 5) NATIONAL FIRE ALARM CODE 3. TYPE OF FIRE ALARM SYSTEM OR SERVICE (continued) If Chapter 8, note the means of transmission from the protected premises to the central station: 2f Digital alarm communicator ❑ McCulloh ❑ Multiplex ❑ 2 -way radio ]14 1 -way radio ❑ N/A If Chapter 9, note the type of connection: 0 Local energy ❑ Shunt 'N /A 3.1 System Software Operating system (executive) software revision level: d C) Z • 0 1 Site - specific software revision date: - Z 2 - ' iv 1 Z Revision completed by: r3 r 't G," 4. SIGNALING LINE CIRCUITS Characteristics of signaling line circuits connected to this system (see NFPA 72, Table 6.6.1): Quantity: Style: y Class: 5. ALARM - INITIATING DEVICES AND CIRCUITS Characteristics of initiating device circuits connected to this system (see NFPA 72, Table 6.5): Quantity: Z y Style: Class: B 5.1 Manual initiating devices 'J 5.1.1 Manual Pull Stations Number of manual pull stations: / 7 Type of devices: $ Addressable 0 Conventional ❑ Coded ❑ Transmitter ❑ N/A 5.2 Automatic Initiating Devices 5.2.1 Area Smoke Detectors Number of smoke detectors: 'i 6 Type of coverage: ❑ Complete area Partial area ❑ Nonrequired partial area ❑ N/A Type of devices: RE Addressable 0 Conventional ❑ Coded ❑ Transmitter ❑ N/A Type of smoke detector sensing technology: 0 Ionization ciiPhotoelectric 5.2.2 Duct Smoke Detectors Number of duct smoke detectors: 3 Type of coverage: Type of devices: It Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A Type of smoke detector sensing technology: 0 Ionization R Photoelectric 5.2.3 Heat Detectors Number of heat detectors: 7 Type of coverage: ❑ Complete area it4 Partial area ❑ Nonrequired partial area ❑ N/A Type of devices: ,g Addressable 0 Conventional ❑ Coded 0 Transmitter ❑ N/A 5.2.4 Sprinkler Waterflow Detectors Number of waterflow detectors: Type of devices: > Addressable ❑ Conventional ❑ Coded ❑ Transmitter ❑ N/A 5.2.5 Alarm Verification Number of devices subject to alarm verification: Alarm verification on this system is: ❑ Enabled 0 Disabled ❑ Set for seconds Reprinted with permission from NFPA 72, National Fire Alarm Code®, Copyright ©2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety. © 2007 National Fire Protection Association SG24 -2 -014 Rev. (10/07) (p.2 of 5) FUNDAMENTALS OF FIRE ALARM SYSTEMS 6. SUPERVISORY SIGNAL - INITIATING DEVICES AND CIRCUITS 6.1 Sprinkler System Number of valve supervisory switches: Z ' Type of devices: *23,Addressable ❑ Conventional 0 Coded ❑ Transmitter ❑ N/A 6.2 Fire Pump N/A A Type of fire pump: ❑ Electrical ❑ Diesel Type of pump supervisory devices: 0 Addressable ❑ Conventional ❑ Coded 0 Transmitter i(N /A Fire Pump Functions Supervised 0 Fire pump power ❑ Fire pump running ❑ Fire pump phase reversal ❑ Selector switch not in auto ❑ Engine or control panel trouble ❑ Low fuel Other: 6.3 Engine Driven Generator Al A Type of generator supervisory devices: ❑ Addressable ❑ Conventional ❑ Coded ❑ Transmitter R'N /A ❑ Engine or control panel trouble 0 Generator running 0 Selector switch not in auto ❑ Low fuel Other: 7. ANNUNCIATORS 7.1 Annunciator 1 IL Local ❑ Remote Type: ❑ Addressable ❑ Directory ❑ Graphic ❑ N/A Location: F4Gf 7.2 Annunciator 2 ❑ Local a Remote Type: 'Addressable ❑ Directory ❑ Graphic 0 N/A Location: 1 FL SowIL. Ekr r 7.3 Annunciator 3 ❑ Local 0 Remote Type: O Addressable ❑ Directory ❑ Graphic ❑ N/A Location: 8. ALARM NOTIFICATION DEVICES AND CIRCUITS 8.1 Emergency Voice Alarm Service Number of single voice alarm channels: Number of multiple voice alarm channels: Number of speakers: Number of speaker zones: 8.2 Telephone Jacks Number of telephone jacks installed: Number of telephone handsets stored on site: Type of telephone system installed: ❑ Electrically powered ❑ Sound powered ❑ N/A 8.3 Nonvoice Audible System Characteristics of notification device circuits connected to this system (see NFPA 72, Table 6.5): Quantity: 3L/ Style: Class: 3 Reprinted with permission from NFPA 72, National Fire Alarm Code®, Copyright ©2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety. © 2007 National Fire Protection Association SG24 -2 -014 Rev. (10/07) (p.3 of 5) • NATIONAL FIRE ALARM CODE • 8. ALARM NOTIFICATION DEVICES AND CIRCUITS (continued) 8.4 Types and Quantities of Nonvoice Notification Appliances Installed Bells: With visual device Horns: / ¥ With visual device: ( Chimes: With visual device Bells: With visual device: Visual devices without audible devices: �9 Other (describe): 9. EMERGENCY CONTROL FUNCTIONS ACTIVATED Hold -open door releasing devices ❑ Smoke management or smoke control 'Door unlocking X Elevator recall ❑ Other 10. SYSTEM POWER SUPPLY 10.1 Primary Power Nominal voltage I 2-0 1/ A-C Amps / 0 .4 Overcurrent protection: Type c - lL T Ere k-e r Amps Lc.) 4 Location (of primary supply panelboard): Disconnecting means location: 10.2 Secondary Power Location: F Type: Rio-4-ex Nominal voltage: av 4C Current rating: BOA Number of standby batteries: Z. Amp hour rating: 33A- N- Location of emergency generator: n//.4- Location of fuel storage: Calculated capacity of secondary power to drive the system In standby mode: 2N Gt c5 In alarm mode: S 11. RECORD OF SYSTEM INSTALLATION Fill out after all installation is complete and wiring has been checked for opens, shorts, ground faults, and improper branching, but before conducting operational acceptance tests. The system has been installed in accordance with the following NFPA standards: (Note any or all that apply.) ❑ NFPA 72 ❑ NFPA 70, National Electrical Code, Article 760 ❑ Manufacturer's published instructions ❑ Other (please specify): System deviations from referenced NFPA standards: Signed: Printed name: Date: Organization: Title: Phone: 12. RECORD OF SYSTEM OPERATION All operational features and functions of this system were tested by or in the presence of the signer shown below, on the date shown below, and were found to be operating properly in accordance with the requirements of: ®'NFPA 72 LEKNFPA 70, National Electrical Code, Article 760 Manufacturer's published instructions ❑ Other (please specify): ❑ Documentation in accordance with Inspection and Testing Form (Figure 10.6.2.3) is attached Signed: Printed name: f,,.. I30W APy Date: 11 - s - l Z Organization: S A.V PI x �..a.- ( Title: I p 1. 2P p Phone: S 0 5 - CE 3- 9' Reprinted with permission from NFPA 72, National Fire Alarm Code®, Copyright ©2002, National Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety. © 2007 National Fire Protection Association SG24 -2 -014 Rev. (10/07) (p.4 of 5) . FUNDAMENTALS OF FIRE ALARM SYSTEMS 13. CERTIFICATIONS AND APPROVALS 13.1 System Installation Contractor This system as specified herein has been installed and tested according to all NFPA standards cited herein. • Signed: Printed name: Date: . Organization: Title: Phone: 13.2 System Service Contractor This system as s 'eciffed erein has been installed and tested according to all NFPA standards cited herein. • Signed: Printed name: /-7 f A ,,, /30 i- A V Date: // - S — / Z Organization; S p ' �,`,,,,,, e 1/ Title: it c L. Ie ' O / Phone: $ -6T 3 - 9d o 13.3 Central Station This system as specified herein will be monitored according to all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.4 Property Representative I accept this system as having been installed and tested to its specifications and all NFPA standards cited herein. Signed: Printed name: Date: Organization: Title: Phone: 13.5 Authority Having Jurisdiction I have witne /d a satisfactory ac - s .nce test of this system and find it to be installed and operating properly in accorda / with its apprr ed plans and specifications, its approved sequence of operations, and with all NFPA . standards d her Signed: La� Printed name:e7(}it i'R.'.1 C1l Date: it" d Organization: cr 71 e r- LT 4i Title:Sg -.E >t t_� A/C.1 t NIS I _ Phone: So� 7/ - .2 1 7 / Y Reprinted with permission from NFPA 72, National Fire Alarm Code®, Copyright ©2002, National -Fire Protection Association, Quincy, MA 02169. This reprinted material is not the complete and official position of the National Fire Protection Association on the referenced subject which is represented only by the standard in its entirety. © 2007 National Fire Protection Association SG24 -2 -014 Rev. (10/07) (p.5 of 5) z -0 cx.7 z-/ 0 TroubleLog_2012_5_lla.txt Service Port Page 1 Report 2 : Trouble Historical Log 9:28:57 am FRI 11- MAY -12 ENTRY 1 7:39:20 am FRI 11- MAY -12 HISTORICAL LOG CLEARED AT MAIN PANEL ENTRY 2 7:39:38 am FRI 11- MAY -12 WALK TEST GROUP 0 ENABLED TROUBLE POINT ABNORMAL ENTRY 3 7:39:43 am FRI 11- MAY -12 TROUBLES ACKNOWLEDGED AT MAIN PANEL ENTRY 4 7:50:46 am FRI 11- MAY -12 LEVEL =1 AT MAIN PANEL BY OPERATOR 1 ENTRY 5 7:57:32 am FRI 11- MAY -12 L5 PH ELEVATOR MACH RM M1 -199 HEAT DETECTOR FIRE ALARM WALKTEST ENTRY 6 7:57:38 am FRI 11- MAY -12 L5 PH ELEVATOR MACH RM M1 -198 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 7 7:57:44 am FRI 11- MAY -12 L5 PH ELEVATOR MACH RM M1 -195 HEAT DETECTOR FIRE ALARM WALKTEST ENTRY 8 7:57:51 am FRI 11- MAY -12 L5 PH ELEVATOR MACH RM M1 -196 HEAT DETECTOR FIRE ALARM WALKTEST ENTRY 9 7:57:52 am FRI 11- MAY -12 L5 PH ELEVATOR MACH RM M1 -196 HEAT DETECTOR FIRE ALARM WALKTEST ENTRY 10 7:58:03 am FRI 11- MAY -12 L5 PH ELEVATOR MACH RM M1 -197 SMOKE DETECTOR FIRE ALARM WALKTEST Service Port Page 2 Report 2 : Trouble Historical Log 9:28:58 am FRI 11- MAY -12 ENTRY 11 7:58:03 am FRI 11- MAY -12 L5 PH ELEVATOR MACH RM M1 -197 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 12 7:58:03 am FRI 11- MAY -12 L5 PH ELEVATOR MACH RM M1 -197 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 13 7:58:08 am FRI 11- MAY -12 L5 PH ELEVATOR MACH RM M1 -200 HEAT DETECTOR FIRE ALARM WALKTEST ENTRY 14 8:00:53 am FRI 11- MAY -12 L5 7FL WEST STAIRWELL M1 -170 PULL STATION FIRE ALARM WALKTEST ENTRY 15 8-: -01:01 am FRI 11- MAY -12 L5 7FL WEST CORR. NEAR STAIRWELL M1 -171 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 16 8:01:31 am FRI 11- MAY -12 L5 7FL WEST CORR. NEAR SUITE 750 M1 -172 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 17 8:01:46 am FRI 11- MAY -12 L5 7FL ELEVATOR LOBBY M1 -173 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 18 8:02:13 am FRI 11- MAY -12 L5 7FL EAST CORRIDOR M1 -175 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 19 8:02:13 am FRI 11- MAY -12 L5 7FL EAST CORRIDOR M1 -175 SMOKE DETECTOR FIRE ALARM WALKTEST Service Port Page 3 Report 2 : Trouble Historical Log 9:29:00 am FRI 11- MAY -12 ENTRY 20 8:02:22 am FRI 11- MAY -12 L5 7FL EAST CORR. NEAR STAIRWELL M1 -178 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 21 8:03:14 am FRI 11- MAY -12 L5 7FL EAST STAIRWELL M1 -179 PULL STATION FIRE ALARM WALKTEST ENTRY 22 8:03:39 am FRI 11- MAY -12 L5 7FL SPRINKLER RISER TAMPER M1 -180 SPRINKLER MONITOR ABNORMAL WALKTEST ENTRY 23 8:05:16 am FRI 11- MAY -12 L5 6FL SPRINKLER RISER TAMPER M1 -145 SPRINKLER MONITOR ABNORMAL WALKTEST ENTRY 24 8:05:53 am FRI 11- MAY -12 L5 5FL SPRINKLER RISER TAMPER M1 -125 SPRINKLER MONITOR ABNORMAL WALKTEST ENTRY 25 8:06:22 am FRI 11- MAY -12 L5 4FL SPRINKLER RISER FLOW M1 -101 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 26 8:07:02 am FRI 11- MAY -12 L5 4FL EAST STAIRWELL M1 - PULL STATION FIRE ALARM WALKTEST Page 1 TroubleLog_2012_5_11a.txt ENTRY 27 8:07:08 am FRI 11- MAY -12 L5 4FL EAST CORR. NEAR STAIRWELL M1 -98 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 28 8:07:08 am FRI 11- MAY -12 L5 4FL EAST CORR. NEAR STAIRWELL M1 -98 SMOKE DETECTOR FIRE ALARM WALKTEST Service Port Page 4 Report 2 : Trouble Historical Log 9:29:01 am FRI 11- MAY -12 ENTRY 29 8:07:19 am FRI 11- MAY -12 L5 4FL EAST CORR. NEAR ELEC RM M1 -95 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 30 8:07:28 am FRI 11- MAY -12 L5 4FL EAST CORR. NEAR SUITE 400 M1 -93 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 31 8:07:36 am FRI 11- MAY -12 L5 4FL ELEVATOR LOBBY M1 -94 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 32 8:07:47 am FRI 11- MAY -12 L5 4FL WEST CORRIDOR AT RESTROOMS M1 -92 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 33 8:07:57 am FRI 11- MAY -12 L5 4FL WEST STAIRWELL M1 -91 PULL STATION FIRE ALARM WALKTEST ENTRY 34 8:08:04 am FRI 11- MAY -12 L5 4FL WEST CORRIDOR M1 -90 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 35 8:08:04 am FRI 11- MAY -12 L5 4FL WEST CORRIDOR M1 -90 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 36 8:09:19 am FRI 11- MAY -12 L5 3FL WEST CORRIDOR M1 -60 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 37 8:09:29 am FRI 11- MAY -12 L5 3FL WEST STAIRWELL M1 -61 PULL STATION FIRE ALARM WALKTEST Service Port Page 5 Report 2 : Trouble Historical Log 9:29:02 am FRI 11- MAY -12 ENTRY 38 8:09:36 am FRI 11- MAY -12 L5 3FL WEST CORRIDR AT RESTROOMS M1 -62 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 39 8:10:01 am FRI 11- MAY -12 L5 3FL ELEVATOR LOBBY M1 -63 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 40 8:10:10 am FRI 11- MAY -12 L5 3FL EAST CORRIDOR NEAR ELEC RM M1 -64 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 41 8:10:21 am FRI 11- MAY -12 L5 3FL EAST CORR. NEAR STAIRWELL M1 -68 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 42 8:10:40 am FRI 11- MAY -12 L5 3FL EAST STAIRWELL M1 -67 PULL STATION FIRE ALARM WALKTEST ENTRY 43 8:10:57 am FRI 11- MAY -12 L5 3FL SPRINKLER RISER TAMPER M1 -69 SPRINKLER MONITOR ABNORMAL WALKTEST ENTRY 44 8:11:29 am FRI 11- MAY -12 L5 2FL SPRINKLER RISER TAMPER M1 -41 SPRINKLER MONITOR ABNORMAL WALKTEST ENTRY 45 8:12:26 am FRI 11- MAY -12 L5 2FL EAST STAIRWELL M1 -40 PULL STATION FIRE ALARM WALKTEST ENTRY 46 8:12:33 am FRI 11- MAY -12 L5 2FL EAST CORRIDOR M1 -39 SMOKE DETECTOR FIRE ALARM WALKTEST Service Port Page 6 Report 2 : Trouble Historical Log 9:29:03 am FRI 11- MAY -12 ENTRY 47 8:12:55 am FRI 11- MAY -12 L5 2FL NORTH CORE AREA M1 -36 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 48 8:13:42 am FRI 11- MAY -12 L5 2FL ELEVATOR LOBBY M1 -33 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 49 8:13:59 am FRI 11- MAY -12 L5 2FL SOUTH CORE AREA M1 -34 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 50 8:13:59 am FRI 11- MAY -12 L5 2FL SOUTH CORE AREA M1 -34 SMOKE DETECTOR FIRE ALARM WALKTEST Page 2 TroubleLog_2012_5_11a.txt ENTRY 51 8:14:20 am FRI 11- MAY -12 L5 2FL WEST CORRIDOR AT RESTROOMS M1 -32 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 52 8:14:30 am FRI 11- MAY -12 L5 2FL WEST CORRIDOR M1 -30 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 53 8:14:39 am FRI 11- MAY -12 L5 2FL WEST STAIRWELL M1 -31 PULL STATION FIRE ALARM WALKTEST ENTRY 54 8:16:03 am FRI 11- MAY -12 L5 1FL SW ENTRY CORRIDOR M1 -2 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 55 8:16:15 am FRI 11- MAY -12 L5 1FL W. CORRIDOR BY STAIRWELL M1 -3 SMOKE DETECTOR FIRE ALARM WALKTEST Service Port Page 7 Report 2 : Trouble Historical Log 9:29:05 am FRI 11- MAY -12 ENTRY 56 8:16:23 am FRI 11- MAY -12 L5 1FL W. CORRIDOR BY RESTROOMS M1 -4 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 57 8:16:42 am FRI 11- MAY -12 L5 1FL SOUTH ENTRY VESTIBULE M1 -7 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 58 8:16:55 am FRI 11- MAY -12 L5 1FL SOUTH ENTRY VESTIBULE M1 -6 PULL STATION FIRE ALARM WALKTEST ENTRY 59 8:17:17 am FRI 11- MAY -12 L5 1FL ELEVATOR LOBBY M1 -9 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 60 8:17:17 am FRI 11- MAY -12 L5 1FL ELEVATOR LOBBY M1 -9 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 61 8:17:27 am FRI 11- MAY -12 L5 1FL NORTH ENTRY VESTIBULE M1 -10 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 62 8:17:36 am FRI 11- MAY -12 L5 1FL NORTH ENTRY VESTIBULE M1 -11 PULL STATION FIRE ALARM WALKTEST ENTRY 63 8:18:30 am FRI 11- MAY -12 L5 5FL ELEVATOR LOBBY M1 -121 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 64 8:19:51 am FRI 11- MAY -12 L5 5FL ELECTRICAL ROOM M1 -122 SMOKE DETECTOR FIRE ALARM WALKTEST Service Port Page 8 Report 2 : Trouble Historical Log 9:29:06 am FRI 11- MAY -12 ENTRY 65 8:20:08 am FRI 11- MAY -12 L5 5FL EAST STAIRWELL M1 -124 PULL STATION FIRE ALARM WALKTEST ENTRY 66 8:21:05 am FRI 11- MAY -12 L5 5FL WEST STAIRWELL M1 -120 PULL STATION FIRE ALARM WALKTEST ENTRY 67 8:23:14 am FRI 11- MAY -12 L5 6FL EAST STAIRWELL M1 -144 PULL STATION FIRE ALARM WALKTEST ENTRY 68 8:23:33 am FRI 11- MAY -12 L5 6FL ELECTRICAL ROOM M1 -142 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 69 8:24:21 am FRI 11- MAY -12 L5 6FL WEST STAIRWELL M1 -140 PULL STATION FIRE ALARM WALKTEST ENTRY 70 8:25:13 am FRI 11- MAY -12 L5 6FL ELEVATOR LOBBY M1 -141 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 71 8:26:28 am FRI 11- MAY -12 L5 1FL MAIL ROOM M1 -8 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 72 8:26:44 am FRI 11- MAY -12 L5 1FL ELECTRICAL ROOM M1 -13 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 73 8:29:02 am FRI 11- MAY -12 L5 1FL BY CENTRAL STAIRWELL M1 -12 SMOKE DETECTOR FIRE ALARM WALKTEST Service Port Page 9 Report 2 : Trouble Historical Log 9:29:07 am FRI 11- MAY -12 ENTRY 74 8:29:27 am FRI 11- MAY -12 L5 1FL SPRINKLER RISER #1 TAMPER M1 -14 SPRINKLER MONITOR ABNORMAL WALKTEST Page 3 TroubleLog_2012_5_11a.txt ENTRY 75 8:29:39 am FRI 11- MAY -12 L5 1FL SPRINKLER RISER #1 FLOW M1 -15 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 76 8:31:17 am FRI 11- MAY -12 L5 2FL EAST CORE AREA M1 -35 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 77 8:31:17 am FRI 11- MAY -12 L5 2FL EAST CORE AREA M1 -35 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 78 8:34:16 am FRI 11- MAY -12 L5 2FL ELECTRICAL ROOM M1 -37 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 79 8:35:41 am FRI 11- MAY -12 L5 3FL ELECTRICAL ROOM M1 -65 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 80 8:38:35 am FRI 11- MAY -12 L5 7FL ELECTRICAL ROOM M1 -176 SMOKE DETECTOR FIRE ALARM WALKTEST ENTRY 81 8:52:03 am FRI 11- MAY -12 L5 1FL SPRINKLER RISER #1 FLOW M1 -15 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 82 8:52:41 am FRI 11- MAY -12 L5 1FL SPRINKLER RISER #1 TAMPER M1 -14 SPRINKLER MONITOR ABNORMAL WALKTEST Service Port Page 10 Report 2 : Trouble Historical Log 9:29:08 am FRI 11- MAY -12 ENTRY 83 8:57:47 am FRI 11- MAY -12 L5 1FL SPRINKLER RISER #2 FLOW M1 -17 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 84 9:01:06 am FRI 11- MAY -12 L5 2FL SPRINKLER RISER FLOW M1 -42 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 85 9:03:36 am FRI 11- MAY -12 L5 3FL SPRINKLER RISER FLOW M1 -70 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 86 9:06:17 am FRI 11- MAY -12 L5 4FL SPRINKLER RISER TAMPER M1 -100 SPRINKLER MONITOR ABNORMAL WALKTEST ENTRY 87 9:07:05 am FRI 11- MAY -12 L5 4FL SPRINKLER RISER TAMPER M1 -100 SPRINKLER MONITOR ABNORMAL WALKTEST ENTRY 88 9:09:16 am FRI 11- MAY -12 L5 5FL SPRINKLER RISER FLOW M1 -126 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 89 9:11:26 am FRI 11- MAY -12 L5 6FL SPRINKLER RISER FLOW M1 -146 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 90 9:12:01 am FRI 11- MAY -12 L5 6FL SPRINKLER RISER FLOW M1 -146 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 91 9:12:11 am FRI 11- MAY -12 L5 6FL SPRINKLER RISER FLOW M1 -146 WATERFLOW MONITOR FIRE ALARM WALKTEST Service Port Page 11 Report 2 : Trouble Historical Log 9:29:10 am FRI 11- MAY -12 ENTRY 92 9:13:26 am FRI 11- MAY -12 L5 6FL SPRINKLER RISER FLOW M1 -146 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 93 9:14:21 am FRI 11- MAY -12 L5 6FL SPRINKLER RISER FLOW M1 -146 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 94 9:14:25 am FRI 11- MAY -12 L5 6FL SPRINKLER RISER FLOW M1 -146 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 95 9:15:31 am FRI 11- MAY -12 L5 6FL SPRINKLER RISER FLOW M1 -146 WATERFLOW MONITOR FIRE ALARM WALKTEST ENTRY 96 9:17:20 am FRI 11- MAY -12 L5 7FL SPRINKLER RISER FLOW M1 -181 WATERFLOW MONITOR FIRE ALARM WALKTEST TROUBLE HISTORICAL LOG REPORT COMPLETED Page 4