June 26, 2006
CITY OF TIGARD
OREGON
Arbuckle Costic Architects
Claytbn Vorse
363 State St
Salem, OR 97301
RE: ADVANCE NUTRITION - REVIEW
Project Information
Building Permit BUP2006 -00255 Construction Type: II-B
Tenant Name: Advance Nutrition Occupancy Type: M
Address: 9751 SW Washington Sq Occupant Load: 49
Area: 1,457 sq ft Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition;
and the State of Oregon Fire Code (OFC) 2004 edition. The submitted plans are approved subject to the
following conditions.
1. The main exterior door or doors are permitted to be equipped with key- operated locking devices from
the egress side provided:
1. The locking device is readily distinguishable as locked,
2. A readily visible durable sign is posted on the egress side on or adjacent to the door
stating. THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED.
The sign shall be in letters 1 inch (25 mm) high on a contrasting background. Sec. 1008.1.8.3
2. All exit doors shall be openable from the inside without the use of a key or any special knowledge
or effort Sec. 1008.1.8
3. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress
travel is not immediately visible to the occupants. Sec. 1011.1
4. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level
anytime the building is occupied. The means of egress illumination shall be provided with a second
source of power in case of primary power loss. Sec. 1006.2
5. Provide one 2 -A rated fire extinguisher in storage area. The extinguisher shall be located so that no
usable space has a distance greater than 75 feet to the extinguisher. OFC 906.3
6. Accessible checkout aisles shall be on an accessible route and at least 36 inches wide. Counters in
accessible checkout aisles shall be not more than 38 inches (965 mm) high and the top of the raised
edge of the counter shall not exceed 40 inches (1016 mm) in height above the finished floor. Accessible
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
checkout aisles shall be identified by the international symbol of access. Sec. 1109.19, 1109.23.3
7. Safety glazing including but not limited to: the following locations: Each unit of glazing shall be
permanently identified by the manufacturer. Sec. 2406. Some of these locations are as follows:
a. Glazing in ingress and means of egress doors.
b. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical
edge is within a 24" arc of the door in a closed position and whose bottom edge is less than
60" above the floor or walking surface except when there is an intervening wall or other
permanent barrier between the door and the glazing.
8. Deferred submittals such as Truss Joist Shop Drawings, suspended ceiling system etc, will be charged
a deferred submittal fee based on the valuation of the portion of the work being deferred. The
minimum fee shall be $200.00. This fee is in addition to the project plan review fee based on the total
project value. OAR 918-050 -0150 Deferred Items: None listed
"Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge who
shall review them and forward them to the building official with a notation indicating that the deferred submittal documents
have been reviewed and been found to be in general cnnfornrancr to the design of the building. The deferred submittal items
shall not be installed until the design and submittal documents have been *proved by the building offuiaL Oregon Structural
•
Specialty Code Section 106.3.4.2"
NOT PART OF THIS REVIEW:
* Electrical * Fire Sprinklers or Alarms * Mechanical System * Plumbing
American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer,
Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the
structure. The City of Tigard reviews the plans and inspects the structure only for compliance with
Chapter 11 of the OSSC, which may not include all of the requirements of the ADA.
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained
on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of
construction. 106.3.1 OSSC
Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official
has issued a certificate of occupancy 109.1 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such
a position as to be plainly visible and legible from the street or road fronting the property.
When submitting revised drawings or additional information, please attach a copy of the enclosed City of
Tigard, Letter of Transmittal The letter of transmittal assists the City of Tigard in tracking and
processing the documents.
Respect
Val Henzel,
Senior Plans Examiner