Loading...
Permit CITY OF TIGARD BUILDING PERMIT ° COMMUNITY DEVELOPMENT Permit #: BUP2008 -00397 .T t GARL) 13125 SW Hall Blvd , Tigard OR 97223 503.639 4171 Date Issued: 03/19/2009 Parcel: 151260000300 Jurisdiction: TIG Site addcessa9665 SW WASHINGTON_SQUARE,RD_CO2 Subdivision: Lot: Project: ARITZIA Project Description: TI Owner: FEES WASHINGTON SQUARE LLC Description Date Amount BY THE MACERICH COMPANY, 9585 SW [BUPPLN] Pln Rv 12/29/2008 $394.36 WASHINGTON SQUARE RD [ELS] FLS Pln Rv 12/29/2008 $242.68 PHONE [BUILD] Permit Fee 03/19/2009 $1,175.80 [TAX] 12% State Surcharge 03/19/2009 $141.10 Contractor: [METCET] Metro Const Excise Tx 03/19/2009 $336.00 R & H CONSTRUCTION CO [BUPPLN] Addl Pln Rv 03/19/2009 $369 91 1530 SW TAYLOR ST [FLS] Addl FLS PInRv 03/19/2009 $227 64 PORTLAND, OR 97205 -1819 PHONE• 503 - 228 -7177 FAX: 503 - 224 -3638 Specifics: Type of Use: COM Class of Work: ALT Dwelling Units: Stories: 1 Height: 18 ft Bedrooms: Bathrooms: Value: $0 Floor Areas: Total Area. Accessory Struct Basement Carport Covered Porch Deck' Garage Mezzanine Total $2,887 49 Required: Required Items and Reports (Conditions) Fire Sprinkler Yes Parapet: Fire Alarm: Yes Protected Corridors: Smoke Detectors Manual Pull Stations Accessible Parking. This permit is issued_subjeect to the regulations contained in the Tigard Municipal Code, State of OR Specialty Codes and at other applicable law At work will be do• - in accordance with approved plans This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 1:. days. ATTENTION O•ego - requir s you to follow the rules adopted by the Oregon Utility Notification Center Those rules are set forth in OAR 95 001 - 0010 through OAR 95 01 -0100 You ay obtain a copy of the rules or direct questions to OUNC by calling 50 246 6. '9 or 1 8 - 332 Is.ued k Permittee Signature: 411 � _re`�■ Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. Buildiri Permit Applic ft EIVED Commercial FOR OFFICE USE ONLY City of Tigard DEC 2 9 2008 Received �'t% Q Q 6 �2 to DateB , At ow a Pennit No t0/µ ��0 �QCJc.J �, Er 13125 SW Hall Blvd., Tigard, OR 97223 Plan Revie Phone: 503.639.4171 Fax:I 'l.®FITIGARD Date/By ( ZI •� Other Permit TIGARD Ins Line: 503.639 Date Rea y 3y: i I' Juri . ® See Page 2 for " ��G DIVI SION Internet: www.tigard- or.go / , : a _., Q .tified/Method: �� Supplemental information t 4 TYPE OF WORK ' R G I ' i 1 DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Perna es are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. 40 Valuation: $ ❑ 1- and 2- family dwelling O Commercial /industrial ❑ Accessory building ❑ Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: C41 7vrt-'J iv V, itfr; ,1 tar,, .1 jv $ 4 New dwelling area: square feet City /State /ZIP: D 1723 Garage /carport area: square feet Suite/bldg. /apt. no.: Project name: f4ji i z.,A Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. Valuatiofl:?i85 $ TcN NT (A< 7V . 1•V IN i 4OL eme IleJS/ /•rt Existing building area: 3 7f square feet l " � Ne w building area: s �iNl 13iQdu�tN0+1T Nt7� tZ6G7>�K�AC M g 3j square feet q y9 4 � 1 �� ta3 t x. Number of stories: Name: MACFLIC.P1 --- 64€1 1 1 746y>!AC Type of construction: taws C tiosi it C ) Address: i 141 NWQrt 1 'rt)m 7ztvtevAa Occupancy groups: City /State /ZIP: P NIX Z! Existing: Fr M L T1 GE Phone: (t Z) Q[? f 7S7 Fax: ( ) r,Dr� .,rtE New: F _. Al tl Q APPLICANT ❑ CONTACT PERSON NOTICE N. Business name: & ail 4 All contractors and subcontractors are required to he Contact name: Jeff C,ityrme Vt licensed with the Oregon Construction Contractors Board tell under ORS 701 and may be required to be licensed in the Address: 2. 4 — Cp f� —�— . jurisdiction in which work is being performed. If the City /State/ZIP: ' JC ..v f 'G Crw.4. 4 VOA 1 applicant is exempt from licensing, the following reasons -- apply: Phone: (CO.) S �r l gIS Z I Fax: : (C4) 2 S ( — �y 5 E -mail: 1 ^,rr,r ,; ,a rte^►r, - ,-..t- CONTRACTOR 115 D Business name: i a4lv,94 BUILDING PERMIT FEES* (Please refer to fee schedule) Address: 13 City / State/ZIP: Structural plan review fee (or deposit): e q. 3(D Phone: ( ) I Fix: ( ) FLS plan review fee (if applicable): g 42 • tog CCB lic.: g F Total fees due upon application: G 37 i Q / e.,,f,e, Amo unt received: L 37 . Q y Authorized Signature: ,r,'fr,(`j This permit application expires if a permit is not obtained within l80 days after it has been accepted as complete. Print name: 5.4 F C UTi..E. R Date: p EC 2_2_/0e * Fee methodology set by Tri- County Building Industry Service Board. 1:\Building\Permits\BUP -COM PermitApp.doc 2/23 /07 440- 4613T(l1/02 /COM/WEB) 76 �5 . svo( Cod � �° s =0_0 3 9 7 oCeDie Form 4a Project Name: SYSTEMS - GENERAL O: ' i tg Applicability Plans /Specs Discussion of qualifying Show compliance by including a drawing sheet. detail number, exceptions on page 4 -25 specification section and subparagraph. 1. Applicablity (Section 1317) Is this form required? Form Required. Complete form if a new HVAC system is being installed, or components of an existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception 1J -1 El -2 ❑ -3 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) ❑ Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ,14 Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. • 3. Equipment Performance (Section 1317.5) II No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. ❑ Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: ❑ -4a ❑ -4b ❑ -4c ❑ -4d ❑ -4e ❑ -4f ❑ -4g ❑ -4h ❑ -4i ❑ -4j 4. Duct Insulation and Sealing (Sections 1317.7 661317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as required by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) ( ' { „d. No Distribution Transformers. The plans /specs do not call for new distribution transformers. ❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. t t - Exce ion. The project qualifies for an exception per Section 1316 1.1, Exceptiion: ❑ P� p l q p P P�� 0-1 0-2 0-3 0-4 0-5 0-6 0-7 0-8 0-9 0-10 ❑ -11 0 -12 0-13 0-14 Attach relevant documentation for appropriate exception. The plans /specs show compliance in the following locations: .4�^ 4 -1 April 2005 Compliance with OSSC. effective 01/01/05 Form 4a Project Name. - if ,. - Page SYSTEMS - GENERAL Part 2 of 6 6. HVAC Controls (Section 1317.4) X 6.1 System Thermostat /Zone Controls (Section 1317.4.1) Complies All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4 2, Exception U -1 ❑ -2 . Portions of the building that qualify: The plans /specs show compliance in the following locations: 6.2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3) a Complies. Systems must have at least one of the following features: ❑ Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces Equipment Shutdown Complies. Each system is equipped with controls capable of reducing eneoy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception ❑ -1 ❑ -2 • The plans /specs show compliance in the following locations: 6.3 Control Capabilities (Sec. 1317.4.2.1) � WComplies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception ❑ -1 ❑ -2 Portions of the building that qualify: The plans /specs show compliance in the following locations: 6.4 Optimum Start Controls (Section 1317.4.3.2) Complies. Separate HVAC systems have controls capable of varying start -up time of system to just meet temperature set point at time of occupancy. ❑ Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: } c, � 6.5 Heat Pump Controls (Section 1317.4.4) ,4 No Heat Pump. The plans /specs do not call for a new heat pump ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. % The plans /specs show compliance in the following locations: • 89a! 4 -2 April 2005 Compliance with OSSC. effective 01!01/05 • Form 4a Project Name: f >' . t Page. SYSTEMS - GENERAL Part 3 of 6 �7. Economizer Cooling (Section 1317.3) fa No Cooling. The building plans do not call for a new fan system with mechanical cooling. ❑ Complies. Each new fan system has an air economizer capable of modulating outside -air and return -air dampers to provide up to 100 percent of the design supply air as outside air. ❑ Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317.3, Exception ❑ -1 ❑ -2 U -3 ❑ -4 ❑ -5 ❑ -6 If Exception 3 is selected complete the following. (a) Total cooling capacity of exempt units (Btu /hr) (b) Total installed building cooling capacity (Btu /hr) ❑ Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 or alb < 0.10 (10% of total building cooling capacity). Unit Identifier of exempt units The plans /specs show compliance in the following locations: • 8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2) cZiNo Economizers Required. Project does not contain a new fan system requiring economizers_ ` ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that wiil relieve the extra air introduced by the economizer. ❑ Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. ❑ Exception. The applicable exception is Section 1317.3.2, Exception U -1 ❑ -2 The plans /specs show compliance in the following locations: 9 Hot Gas Bypass (Section 1317.5) f - 14]_No Hot Gas Bypass ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity Allowable Hot Gas Bypass V Rated Cooling Capacity Max Hot Gas Bypass <240,000 Btu /hr 50% >240,000 Btu /hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h 4-3 April 2005 Comphance with OSSC, effective 01/01/05 // r-r , • Form 4a Project Name: % t" Page: SYSTEMS - GENERAL Part 4 of 6 \ 1Q. Shutoff Dampers (1317.4.3.3) , Not Required. Shutoff dampers are not required on this project. ❑ Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers ❑ Exception. The building qualifies for an exception to the motorized damper requirement. The applic -able code exception is Section 1317.4.3.3 Exception ❑ -1 U -2 U -3 ❑ - ® -5 The plans /specs show compliance in the following locations: , ,10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) ,,. Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. ❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. The plans /specs show compliance in the following locations: 10.2. Motorized Damper Leakage (1317.4.3.3.2) / 0 Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. ® Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: c'� -. 1 v / /1---;`),,- 11. Piping Insulation (Section 1314) O No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. 4 Complies. All new piping serving a heating or cooling system or part of a circulating service k •-;.:..;,3/4 f water heating system complies with the requirements of the Code, Section 1314.1. �� : ',4 1 , 2 Exception. New piping qualifies for exception: Section 1314.1, Exception ❑ - ❑ -2 12. Occupancy Ventilation . 1: Complies. Mechanical ventilation systems provide the required amount of ventilation specified in Chapter 4 of the Oregon Mechanical Specialty Code. U Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet The plans /specs show compliance in ,, , the following locations:� tL °'` The plans /specs show compliance on the following pages: 14-4 April 2005 Compliance with OSSC, effective 01/01/05 • Form 4a Project Name. / `— t- E J - Page - SYSTEMS - GENERAL Part 5 of 6 13. High Occupancy Ventilation (Section 1317.2.2) CI Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: — Plans /specs indicate where equipment (i e. carbon dioxide sensor) and sequence is specified: ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. No High Occupancy Systems. Project does not contain an HVAC system as described above. 4. Exhaust Air Heat Recovery (Section 1318.3) Al Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception ❑ -1 Li -2 ❑ -3 (J ❑ -5 ❑ -6 J -7 The plans /specs show compliance in the following locations. 15. Large Volume Fan Systems (Section 1318.4.2.4) ❑ Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2 3. The plans /specs show compliance in the following ,. locations: 16. Variable Speed Drives (Section 1317.10.3.1) ® Not Regulated. The building plans or specifications do not call for fan and pump motors 10 v horsepower and greater that serve variable -flow air or liquid systems. f all Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following locations: � ( ' £ _ / . _ - i 1 7 . Service Water Heating (Sec. 1315) No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. ❑ Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: 1 Portions of the building that qualify: The plans /specs show compliance in the following locations: 4 -5 April 2005 Compliance with OSSC, effective 01101)05 Form 4a Project Name: /,;.-_ : ''.` Page: SYSTEMS - GENERAL Part 6 of 6 8. Swimming Pools, Spas and Hot Tubs (Section 1315.5) No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: ❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: \ 20. Parking Garage Ventilation (Section 1317.2.3) I No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at , least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. The plans /specs show compliance in the following locations: 22. Outside Heating Systems (Section 1317.12) No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. U Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317 12. 4 -6 April 2005 Compliance with OSSC, effective 01/01/05 Form 4b Project Name /"/" r "'.i> Page: COMPLEX HVAC SYSTEMS Part 1 of 3 Applic- 1. Simple or Complex Systems (Section 1317.9, 1317.10 and 1318) ability Note: This form is required for complex systems only. If your plans qualify as a simple Discussion of system as defined by the code, this form is not required. qualifying excep- lions in instructions 2, Air Transport Energy (Section 1318.4.2) section. Not Regulated. Each HVAC system does not have total fan nameplate horsepower of 7 5 HP Fan Motor or greater (include sum of all supply, return, & exhaust fans operating at design conditions). Energy ❑ Brake Horsepower Complies. The energy demand of all HVAC fan systems meets code Sae Section 1318 4 2 for requirements. Complete and attach Worksheet 41. maximum horse- ❑ Nameplate Horsepower Complies. Selected fan motors have nameplate ratings no larger power allowed than is allowed by Section 1318.4.2.3. (Complete Worksheet 4L.) ❑ Exception. Section 1318.4.2, Exception ❑ -1 O -2 ❑ -3 ❑ -4 Portions of the building that qualify: L _1 The plans /specs show compliance in the following locations: Cooling 3. Cooling Tower Fans (Section 1317.5.4.1) Tower ;Cf, No Cooling Tower There is no cooling tower in this project. Fans ❑ Complies. Cooling tower fans have control devices that vary flow by controlling leaving fluid temperature or condenser temperature /pressure of the heat rejection device. The plans /specs show compliance in the following locations: 4. Simultaneous Heating and Cooling (Section 1318.2.1) ❑ No Cooling. The building HVAC system has no cooling. ) 1 Complies. Controls prevent reheating, retooling or mixing of mechanically heated and mechanically cooled air. ❑ Exception. Code exception is Section 1318.2.1, Exception ❑ -1 ❑ -2 ❑ -3 ❑ -4 ❑ -5 If exception 1 is used, complete and attach Worksheet 4k Portions of the building that qualify: The plans /specs show compliance in the following locations: 5. Electric Motor Efficiency (Section 1317.10.3 85 Table 13 - T) Li Not Regulated. There are no NEMA Design A &B squirrel cage,T -frame induction, --11 permanently wired polyphase motors of one horsepower or more which serve built up HVAC Complies. The efficiency of all regulated motors meets code requirements. Exceptions ❑ Exception. Section 1317.10.3, Exception ❑ -1 ❑ -2 Discussion of qualifying Portions of the building that qualify: exceptions in instructions The plans /specs show compliance in the following locations: 6. VAV System Static Pressure Reset Controls (Section 1318.2.3) ❑ Not Regulated. The building plans or specifications do not call for a VAV system controlled by a static pressure sensor or direct digital control of individual zone boxes. ,Zi, Complies. The system static pressure set point automatically resets to the lowest point possible while still providing the required air flow to the zones with the greatest demand. (-� F [3 Exception. Section 1318.2.3, Exception �� ' °';i' } The plans /specs show compliance in ,rpm r y £,G.'= G i A . ;'.i (,'.. � _ 1..( :'j-.- 17 7 '9 r the following locations: 4 -7 April 2005 Compliance with OSSC. effective 01101105 Form 4b Project Name: r l "_ ,,: Page: COMPLEX HVAC SYSTEMS . Part 2 of 3 7. VAV Terminal Units (Section 1317.4.2.1) g Not Regulated. Project does not contain VAV terminal units. ,, Complies. VAV terminal units are programmed to operate at the minimum airflow setting without addition of reheat when the zone temperature is within the set deadband. Complete Worksheet 4k. ❑ Exception. Section 1317.4.2.1, Exception ❑ -1 ] -2 The plans /specs show compliance in the following locations: 1-4:1, �8. Supply - Air Temperature Reset Controls (Section 1318.2.5) ,I;y Not Regulated. The building plans or specifications do not call for multiple zone HVAC systems. . ❑ Complies. Multiple zone HVAC systems include controls that automatically reset the supply -air temperatures in response to building loads or outside air temperature. ❑ Exception. The building qualifies for an exception to the supply -air reset controls requirement. Applicable code exception is Section 1318.2.5, Exception ❑ - ❑ -2 ❑ -3 Portions of the building that qualify: The plans /specs show compliance in the , following locations: c /i/ mil % - —7 t 9. Chilled and Hot Water Temperature Reset Controls (Section 1318.2.4) 4 Not Regulated. The building plans or specifications do not call for chilled or hot water systems with a design capacity exceeding 300,000 Btu /hr. ❑ Complies. Chilled and hot water systems include controls that automatically reset supply water temperatures by representative building loads or by outside air temperature. ❑ Exception. Section 1318.2 :4, Exception ❑ -1 ❑ -2 Portions of the building that qualify: The plans /specs show compliance in the ✓.Z. '.. % ✓"'.. .,1,71,:. 1 following locations: '? 10. Separate Air Distribution Systems (Section 1318.2.7) , P Not Regulated. The building plans or specifications do not call for zones with special process temperature or humidity requirements. ❑ Complies. Separate air distribution systems serve zones with special process temperature or humidity requirements from those zones serving only comfort conditions, or supplementary control provisions are included so primary systems are specifically controlled for comfort purposes only. ❑ Exception. Section 1318.2.7, Exception ❑ -1 ❑ -2 Identify zones with special process requirements: The plans /specs show compliance in the following locations: ( 11. Zone Isolation Controls (Section 1318.2.6) ;0 Not Regulated. Building plans or specifications do not call for I-IVAC systems serving multiple occupancies or floors with >240,000 Btu /hr cooling capacity, or >300,000 Btu /hr heating capacity. ❑ Complies. HVAC systems serving multiple occupancies or floors with >240,000 Btu /hr cooling capacity, or >300,000 Btu /hr heating capacity are equipped with isolation devices capable of automatically shutting off supply air to and from each isolated area. Each isolated area is controlled independently and satisfies temperature setback (Section 1317.4.2) and optimum start control requirements. Central fan system air volume is reduced through fan speed reduction. The plans /specs show compliance in the %ry,i following locations: r , 4 -8 April 2005 Compliance with OSSC, effective 01/01/05 Form 4b Project Name c/a' r'! r--- Page Page COMPLEX HVAC SYSTEMS Part 3 of 3 42. Humidity Controls (Section 1318.2.2) No Moisture Added to Building. The building plans do not call for means to add moisture to maintain specific humidity levels. ❑ Complies All new humidity control systems equipped with a humidistat when required. All humidifier preheating devices have an automatic value to shut off preheat when humidification The plans /specs show compliance in the following locations: .3. Hydronic System Controls (Section 1318.2.8) / No Hydronic System. The building plans or specifications do not call for a new hydronic system. ❑ Complies. The hydronic system complies as follows: 13.1 Variable Flow Controls (Section 1318.2.8.4) ❑ System does not have a 10 hp or greater motor ❑ Complies. System has controls capable of varying pump flow The plans /specs show compliance in the following locations: 13.2 Three - Pipe System (Section 1318.2.8.1) ❑ System does not have a common return system (a three -pipe system) for both hot water and chilled water. 13.3 Two - Pipe Changeover System (Section 1318.2.8.2) ❑ System is not a Two -Pipe Changeover System ❑ Complies. System is: a Designed to allow a deadband between changeover from one mode to the other of at least 15 °F outside air temperature. b. Designed to operate and provided with controls that will allow operation in one mode for at least four hours before changing over to the other mode. c. Provided with reset controls that allow heating and cooling supply temperatures at the changeover point to be no more than 30 °F apart. The plans /specs show compliance in the following locations: 13.4 Hydronic (Water Loop) Heat Pump System (Section 1318.2.8.3) ❑ System is not a Hydronic (Water Loop) Heat Pump System ❑ Complies. Hydronic heat pumps connected to a common heat pump water loop with central devices for heat rejection (e.g., cooling tower) and heat addition (e.g., boiler) have the following: a. Controls installed capable of providing a heat pump water supply temperature • deadband of at least 20 °F between initiation of heat rejection and heat addition by the central devices (e.g., tower and boiler) b. Closed- circuit tower (fluid cooler) has either an automatic valve installed to bypass all but a minimal flow of water around the tower (for freeze protection), or low- leakage positive closure dampers. c. Open- circuit tower installed directly in the heat pump loop has an automatic valve installed to bypass all heat pump water flow around the tower. Open - circuit towers used in conjunction with a separate heat exchanger to isolate the tower from the heat pump loop are controlled by shutting down the circulation pump on the cooling tower loop. d. A two - position valve at each hydronic heat pump for hydronic systems having a total pump system power exceeding 10 hp. The plans /specs show compliance in the following locations: 4 -9 April 2005 Compliance with OSSC. effective 01/01/05 This form is recognized by most Building Departments in the Tri- County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. 1 2 BUILDING DIVISION TUG n R TRANSMITTAL LETTER TO: f)c n DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED JAN 16 2009 FROM: ORA) d 0 CITY OFTIGARD BUILDING DIVISION COMPANY: PHONE: BycZ RE: 14 20C)S - OC3q (Site Address) (Permit/Case Number) (Project name or subdivision name and lot number) • ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description: Copies: Description: Additional set(s) of plans. Revisions: Cross section(s) and details. Wall bracing and/or lateral analysis. Floor /roof framing. Basement and retaining walls. Beam calculations. Engineer's calcul tions. Other (explain): :) , I i) - se_ Ock r o U t) \-Ck1e r REMARKS: FOR OF/ICE ONLY Routed to Permit Techn Date: I � Initia s: Fees Due: ❑ Yes No Fee Descripti Amount II ue: Special Instructions: Reprint Permit (per PE): ❑ Yes ❑ No ❑ Done Applicant Notified: Date: Initials: • I:\Bwlding \Forms \TransmittalLetter - Revisions doc 4/4/07