Specifications qzo iti. aov6 -, 83 \\IS ,_ oi,,,,„ ■ ...... tq Fi re & Buildin g 10 Products FN 'y �� AL c1 1 3 Chstomer Service/Sales: Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 4 � ,I: (215) 362 -0700 / (800) 523 -6512 w 'r Fax: (215) 362 -5385 Series TY -B — 5.6 K- factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage Corrosion resistant coatings, where General applicable, are utilized to extend the life of copper alloy sprinklers beyond Description that which would otherwise be ob- pe " �_ - , r tained when exposed to corrosive at- 4:1 / ` The Series TY-B, 5.6 K- factor, Horizon- mospheres. Although corrosion resis- „ " ' ' tal a Vertical Sidewall Sprinklers de- tant coated sprinklers have passed the , 1 er !. 'nt, ' " , scribed in this data sheet are standard standard corrosion tests of the appli- 1 i ' ",' : "- response - standard coverage, deco- cable approval agencies, the testing is .€ 4 i,w ?Cr ` rative 5 mm glass bulb type spray not representative of all possible cor- •` : ,r; sprinklers designed for use in light and rosive atmospheres. Consequently, it : ordinary hazard, commercial occupan- is recommended that the end user be cies such as banks, hotels, shopping consulted with respect to the suitability malls, etc.They are designed for instal- of these coatings for any given corre- lation along a wall or the side of a beam sive environment. The effects of ambi- and just beneath a smooth ceiling. ent temperature, concentration of Sidewall sprinklers are commonly chemicals, and gas /chemical velocity,M used instead of endent or upright P should be considered, as a minimum, %���.�,�, { sprinklers due to aesthetics or building along with the corrosive nature of the i construction considerations, where chemical to which the sprinklers will be { piping across the ceiling is not desir- exposed. able. 'i , The recessed version of the Series WARNINGS "1,.,��, ; TY B Horizontal Sidewall Sprinkler Is The Series TY -B Sprinklers describe ° r intended for use in areas with a fin- r FK,f herein must be installed and main- ihed wall. It uses a two-piece Style 10 tamed in compliance with this docu - r� R Recessed Escutcheon. The Recessed ment, as well as with the applicable °,�� Escutcheon provides 1/2 inch (12,7 standards of the National Fire Protec- ��. mm) of recessed adjustment or up to tion Association, in addition to the 3/4 inch (19,1 mm) of total adjustment standards of any other authorities hav from the flush sidewall position. The ing jurisdiction. Failure to do so ma y adjustment provided by the Recessed impair the performance of these de- Technical Escutcheon reduces the accuracy to vices Data which the fixed pipe nipples to the The owner is responsible for maintain- sprinklers must be cut. ing their fire protection system and de- Approvals vices in proper operating condition. UL and C -UL Listed. The installing contractor or sprinkler FM, LPCB, and NYC Approved. manufacturer should be contacted (Refer to Table A for complete approval with any questions. information including corrosion resis- tant status) IMPORTANT Maximum Working Pressure Always refer to Technical Data Sheet TFP700 for the `INSTALLER Model /Sprinkler 175 psi (12,1 bar) WARNING" that provides cautions Discharge Coefficient with respect to handling and instal- identification K = 5.6 GPM /psi (80,6 LPM/barli lation of sprinkler systems and com- ponents. Improper handling and in- Numbers Refer Temperature Table A g stallation can permanently damage ,- a sprinkler system or its compo- TY3351 - Horizontal Finishes nents and cause the sprinkler to fail TY3451 - Vertical Sprinkler: Refer to Table A to operate in a fire situation or cause Recessed Escutcheon: White Coated, it to operate prematurely. Chrome Plated, and Brass Plated Page 1 of 6 JULY, 2004 TFP161 Page2of6 TFP161 SPRINKLER FINISH (See Note 10) K TYPE TEMP. BULB NATURAL CHROME WHITE*" LEAD WAX WAX OVER LIQUID BRASS PLATED POLYESTER COATED COATED LEAD COATED 135 °F /57 °C Orange HORIZ. SIDEWALL 155 °F /68 °C Red (TY3351) 175 °F /79 °C Yellow 1,2,3,4,9 1,2,3,9 1,2,3,9 1,2,3,9 1,2,3,9 200 °F /93 °C Green 5.6 286 °F /141 °C Blue 1", 2•° 3•• 9 ** 1", 2° 3• *, g•+ 1/2" NPT 360 °F /182 °C Mauve 1, 2, 4, 9 1, 2, 9 N/A RECESSED 135 °F /57 °C Orange HORIZ. 155 °F /68 °C Red SIDEWALL (TY3351)' 175 °F /79 °C Yellow 1, 2, 3, 9 N/A Figure 3 200 °F /93 °C Green 135 °F /57 °C Orange VERTICAL 155 °F /68 °C Red 5.6 SIDEWALL 4, 5, 6, 7, 8, 9 5, 6, 7, 9 5, 6, 7, 9 5, 6, 7, 9 1/2" (TY3451) 175 °F /79 °C Yellow NPT Installed 200 °F /93 °C Green Pendent or 286 °F /141 °C Blue 5'•, 6 ", 7", 9" 5•', 6 ", 7'• 9" Upright 360 °F /182 °C Mauve 4, 5, 6, 8, 9 N/A NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 3. Approved by Factory Mutual Research Corporation (FM) for use in Light Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05 & 007k103) at a 4 to 6 inch (100 to 150 mm) deflector to ceiling distance. 5. Listed by Underwriters Laboratories, Inc. (UL) for use in Light and Ordinary Hazard Occupancies. 6. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL:) for use In Light and Ordinary Hazard Occupancies. 7. Approved by Factory Mutual Research Corporation (FM) for use in Light Hazard Occupancies. 8. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05 & 007k/03). 9. Approved by the City of New York under MEA 354 -01 -E. 10. Where Polyester Coated, Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax over Lead Coated Sprinklers are noted to be. FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. ' Installed with Style 10 (1/2° NPT) 3/4" Total Adjustment Recessed Escutcheon. •' 150 °F /66 °C Maximum Ceiling Temperature. "' Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS Physical Characteristics Frame Bronze operation Button Brass /Copper Sealing Assembly The glass Bulb contains a fluid which Beryllium Nickel wfTeflont expands when exposed to heat. When -E Bulb Glass the rated temperature is reached, the Compression Screw Bronze fluid expands sufficiently to shatter the HSW Deflector Bronze glass Bulb, allowing the sprinkler to VSW Deflector Copper activate and water to flow. Patents m U.S.A. 5,810,263 m . a 0 C TFP161 Page 3 of 6 Design DEFLECTOR Criteria HAT \ 5 ,womb The Series TY B Horizontal and Verti- I t ' cal Sidewall Sprinklers are intended ) : ��'�`M for fire protection systems designed in accordance with the standard installa- 6* • 4 2 3 1 tion rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of 9/16' WRENCH 1/2° ** NFPA 13, and FM Approval is based (14,3 mm) FLATS NPT on the requirements of FM's Loss Pre- vention Data Sheets). Only the Style ...10, 11 II 10 Recessed Escutcheon is to be used ` O 7 / I IlleIIIIIII��IIIIIY for recessed horizontal installations. = • = II,nllllllllllllllll) -ix Installation � � I _ 1 13/16° 7/16° The Series TY-B Sprinklers must be (46,0 mm) (11,1 mm) installed in accordance with the follow- CENTERLINE NOMINAL f ..] ing instructions: OF SPRINKLER MAKE -IN NOTES WATERWAY f 11/2° Do not install any bulb type sprinkler if (38,1 mm) the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler _ 2 - 3/16° _ held horizontally, a small air bubble (55,6 mm) should be present. The diameter of the ESCUTCHEON air bubble is approximately 1/16 inch STYLE 10 — PLATE SEATING (1,6 mm) for the 135 °F /57 °C to 3/32 RECESSED I S inch (2,4 mm) for the 360 °F /182 °C ESCUTCHEON temperature ratings. 1- Frame mem 2 - Button A leak tight 1/2 inch NPT sprinkler joint 3 - Sealing '_ ALI! � should be obtained with a torque of 7 4 - BAs 2.7/8• DIA. I ■ I�'� ,�IIIIIIIIIIII to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- 5 - � mum of 21 ft. lbs. (28,5 Nm) of torque Screw may be used to install sprinklers with 6 - Deflector 1/2 NPT connections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make -up for insuffi- cient adjustment in the escutcheon * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. plate by under or over - tightening the * *Pipe thread connections per ISO 7/1 can be provided on special request. sprinkler. Readjust the position of the sprinkler fitting to suit. FIGURE 1 The Series TY -B Horizontal and Ver- 5.6 K- FACTOR STANDARD RESPONSE tical Sidewall Sprinklers must be in- SERIES TV-B HORIZONTAL SIDEWALL (TY3351) SPRINKLERS stalled in accordance with the follow- ing instructions. 1. Horizontal sidewall sprinklers Step 3. Tighten the sprinkler into the bare metal to the corrosive environ- Step 1 are 1 be installed sprinkler fitting using only the W -Type ment. The jaws of the wrench should to with their centerline in in the of e horizontal ont l 6 Sprinkler Wrench (Ref. Figure 4), be opened sufficiently wide to pass position ithi rth back of ter- except that an 8 or 10 inch adjustable over the wrench flats without damag- way perpendicular p o ndlan to the e The ck wall " l T Crescent wrench is to be used for wax ing the wax coating. Before wrench parallel on the l oft the ceiling. tor is to face word "T OP" the coated sprinklers. With reference to tightening the sprinkler, the jaws of the ceiling. Figure 1 or 2, the W -Type 6 Sprinkler wrench are to be adjusted to just con - Wrench or the Crescent wrench, as tact the sprinkler wrench flats. After Vertical sidewall sprinklers are to be applicable, is to be applied to the wrench tightening the sprinkler, loosen installed in the pendent or upright po- wrench flats. the wrench jaws before removing the sition with the arrow on the D eflector When installing wax coated sprinklers wrench. pointing away from the wall. with the adjustable Crescent wrench, After installation, the sprinkler wrench Step 2. With pipe thread sealant ap- additional care needs to be exercised flats and frame arms must be in- plied to the pipe threads, hand tighten to prevent damage to the wax coating spected and the wax coating re- the sprinkler into the sprinkler fitting. on the sprinkler wrench flats or frame touched (repaired) whenever the coat - arms and, consequently, exposure of ing has been damaged and bare metal Page4of6 TFP161 is exposed. The wax coating on the , wrench flats can be retouched by gen- ARROW MUST ` tly applying a heated 1/8 inch diameter POINT AWAY steel rod to the areas of wax that have 7/16° FROM AND BE O p been damaged, to smooth it back over ESCUTCHEON (11,1 mm) PERPENDICULAR /0" O areas where bare metal is exposed. PLATE SEATING ° ** NOMINAL TO THE BACK SURFACE 1/2 MAKE - IN WALL SURFACE 1 NPT NOTES Only retouching of the wax coating ap _ _ , *l; \ * s plied to the wrench flats and frame arms is permitted, and the retouching ��� i� % 5 � — is to be performed only at the time of 2 - 3/16' ■ 2 -3/16° the initial sprinkler installation. (55,6 mm) I dIL�Ih (55,6 mm) I I 4 The steel rod should be heated only to di the point at which it can begin to melt 1 -1/2° WRENCH 11 =MIP r ' < - 2 the wax, and appropriate precautions (38,1 mm) FLATS I P ' � 7 'V need to be taken, when handling the 3 heated rod, in order to prevent the -'._. I 4 1 installer from being burned. If attempts to retouch the wax coating SHOWN SHOWN CROSS with complete coverage are unsuc- PENDENT UPRIGHT SECTION cessful, additional wax can be ordered in the form of a wax stick (the end of 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector which is color coded). Only the correct 2 - Button Assembly 5 - Compression 7- Ejection Spring color coded wax is to be used, and Screw retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. steel rod heated as previously de- **Pipe thread connections per ISO 7/1 can be provided on special request. scribed, touch the rod to the area re- quiring additional wax with the rod an- FIGURE 2 gled downward, and then touch the 5.6 K- FACTOR STANDARD RESPONSE wax stick to the rod approximately SERIES TY-B VERTICAL SIDEWALL one -half inch away from the area re- (TY3451) SPRINKLERS quiring retouching. The wax will melt and run down onto the sprinkler. The Series TY -8 Recessed Horizon- tal Sidewall Sprinklers must be in- corrosive products of combustion, but stalled in accordance with the follow- Care and have not operated, should be replaced ing instructions. if they cannot be completely cleaned Step A. Recessed horizontal sidewall Maintenance by wiping the sprinkler with a cloth or sprinklers are to be installed in the by brushing it with a soft bristle brush. horizontal position with their centerline The Series TY B Sprinklers must be of waterway perpendicular to the back maintained and serviced in accord- Care must be exercised to avoid dam - wall and parallel to the ceiling. The ance with the following instructions: age to the sprinklers - before, during, word "TOP" on the Deflector is to face and after installation. Sprinklers dam towards the ceiling. NOTES aged by dropping, striking, wrench Before closing a fire protection system twist/slippage, or the like, must be re Step B. After installing the Style 10 main control valve for maintenance placed. Also, replace any sprinkler that Mounting Plate over the sprinkler work on the fire protection system that has a cracked bulb or that has lost threads, hand tighten the sprinkler into it controls, permission to shutdown the liquid from its bulb. (Ref. Installation the sprinkler fitting. affected fire protection system must be Section). Step C. Tighten the sprinkler into the obtained from the proper authorities Frequent visual inspections are rec- sprinkler fitting using only the W -Type and all personnel who may be affected ommended to be initially performed for 7 Recessed Sprinkler Wrench (Ref. by this action must be notified. corrosion resistant coated sprinklers, Figure 5). With reference to Figure 1, Absence of an escutcheon, which is after the installation has been com- the W -Type 7 Recessed Sprinkler used to cover a clearance hole, may pleted, to verify the integrity of the cor- Wrench is to be applied to the sprinkler delay the time to sprinkler operation in rosion resistant coating. Thereafter, wrench flats. a fire situation. annual inspections per NFPA 25 should suffice; however, instead of in- . Step D. After the ceiling has been in- Sprinklers that are found to be leaking specting from the floor level, a random stalled or the finish coat has been ap- or exhibiting visible signs of corrosion sampling of close -up visual inspec- plied, slide on the Style 10 Closure must be replaced. tions should be made, so as to better over the Series TY B Sprinkler and determine the exact sprinkler condi- s push the Closure over the Mounting Automatic sprinklers must never be be p Plate until its flange comes in contact painted, plated, coated or otherwise tion and the long term integrity of the with the ceiling. altered after leaving the factory. Modi- corrosion resistant coating, as it may fled sprinklers must be replaced. be affected by the corrosive conditions- - Sprinklers that have been exposed to present. TFP161 Page 5 of 6 5/8±1/4" L, (15,9±6,4 mm) FACE OF WRENCH RECESS MOUNTING SPRINKLER 1 1 E /2 D NPT MODE S SURFACE FITTING FIGURE 4 CLOSURE A W -TYPE 6 SPRINKLER WRENCH I 2 -7/8" DIA. WRENCH SERIES (73,0 mm) RECESS TY B I v`+ II 2 -1/4" DIA. (57,2 mm) !� MOUNTING I ` • r �� 1 PLATE I _ PUSH WRENCH r L 1/8" IN TO ENSURE (3,2 mm) ENGAGEMENT WITH SPRINKLER 1 - 1/4" (31,8 mm) _ 3/4" (19,1 mm) WRENCHING AREA 3/4" (19,1 mm) 1/4" (6,4 mm) FIGURE 5 FIGURE 3 W -TYPE 7 RECESSED SERIES TY-B RECESSED HORIZONTAL SIDEWALL SPRINKLER SPRINKLER WRENCH WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON assume for it, any other obligation in . connection with the sale of products or parts of products. Tyco Fire Products The owner is responsible for the in- Limited parts not be responsible for sprinkler spection, testing, and maintenance of system design errors or inaccurate or their fire protection system and de- w arranty incomplete information supplied by vices in compliance with this docu- Buyer or Buyer's representatives. ment, as well as with the applicable Products manufactured by Tyco Fire IN NO EVENT SHALL TYCO FIRE standards of the National Fire Protec- Products are warranted solely to the PRODUCTS BE LIABLE, IN CON - tion Association (e.g., NFPA 25), in original Buyer for ten (10) years TRACT, TORT, STRICT LIABILITY OR addition to the standards of any other against defects in material and work- UNDER ANY OTHER LEGAL THE - authorities having jurisdiction. The in- manship when paid for and properly ORY, FOR INCIDENTAL, INDIRECT, stalling contractor or sprinkler manu- installed and maintained under normal SPECIAL OR CONSEQUENTIAL facturer should be contacted relative to use and service. This warranty will ex- DAMAGES, INCLUDING BUT NOT any questions. pire ten (10) years from date of ship- LIMITED TO LABOR CHARGES, RE- It is recommended that automatic ment by Tyco Fire Products. No war- GARDLESS OF WHETHER TYCO sprinkler systems be inspected, ranty is given for products or FIRE PRODUCTS WAS INFORMED tested, and maintained by a qualified n not i ted bytu by ow n s ship wnh p wit ABOUT THE POSSIBILITY OF SUCH Fire Prod Inspection Service in accordance nies rdance with Ties DAMAGES AND IN NO EVENT local requirements and /or national Tyco Fire Product ucts or for products and SHALL TYCO FIRE PRODUCTS' LI- codes. components which have been subject ABILITY EXCEED AN AMOUNT to misuse, improper installation, corro- sion, or which have not been installed, EQUAL TO THE SALES PRICE. maintained, modified or repaired in ac- THE FOREGOING WARRANTY IS cordance with applicable Standards of MADE IN LIEU OF ANY AND ALL, the National Fire Protection Associa- OTHER WARRANTIES EXPRESS OR tion, and /or the standards of any other IMPLIED. INCLUDING WARRANTIE$ Authorities Having Jurisdiction. Mate OF MERCHANTABILITY AND FIT- ' rials found by Tyco Fire Products to be NESS FOR A PARTICULAR PUR- defective shall be either repaired or POSE. replaced, at Tyco _ Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to Page6of6 TFP161 P/N 57 -XXX -X- XXX I I • SPRINKLER TEMPERATURE MODEL/SIN RATING 578 HORIZONTAL SIDEWALL TY3351 1 NATURAL BRASS 135 135 °F /57 °C 575 VERTICAL SIDEWALL TY3451 4 WHITE POLYESTER 155 155 °F /68 °C 3 WHITE (RAL9010)• 175 175 °F /79 °C 9 CHROME PLATED 200 200 °F /93 °C 7 LEAD COATED 286 286 °F /141 °C 6 WAX COATED 360 360 °F /182 °C 286 °F /141 °C MAX. 8 WAX OVER LEAD 286 °F /141 °C MAX. • Eastern Hemisphere sales only. TABLE B PART NUMBER SELECTION SERIES TY-B HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS Ordering Recessed Escutcheon: Wax Sticks: Procedure Specify: Style (specify) Recessed Es- (for retouching wrench damaged cutcheon with (specify finish), P/N wax coating) When placing an order, indicate the full (specify). Specify: (Specify color) color coded product name. Refer to the Price List Wax Stick for retouching (specify tern - for complete listing of Part Numbers. 1/2' (15 mm) perature rating) temperature rated Se- Style 10 ries TY B Sprinklers, P/N (specify). Contact your local distributor for avail- Chrome Plated P/N 56- 701 -9-010 ability. 1/2' (15 mm) Style 10 Black for 135 °F P/N 56 -065 -1 -135 Sprinkler Assemblies with NPT White Color Red for 155 °F P/N 56-065-1-155 Coated P/N 56- 701 -4-010 Yellow for 175 °F P/N 56 -065 -1 -175 Thread Connections: 1/2' (15 mm) Blue for 200 °F and Specify: (Specify Model /SIN), Stand- Style 10 286 °F P/N 56- 065 -1 -286 and Response, (specify K- factor), While RAL9010• P/N 56- 701 -3-010 (specify temperature rating), Series 1/2° (15 mm) NOTES T B (specify Horizontal Sidewall or Style 1 0 Y Each wax stick is suitable for retouch - Vertical Sidewall) Sprinkler with (spec- Brass Plated P/N 56- 701 -2 -010 ing up to twenty-five sprinklers. ify type of finish or coating), P/N (spec- • Eastern Hemisphere sales only. The wax used for 286 °F sprinklers is ify from Table B). the same as for 200 °F sprinklers, and, Sprinkler Wrench: therefore, the 286 °F sprinkler is limited Specify: W -Type 6 Sprinkler Wrench, to the same maximum ceiling tempera - P/N 56- 000 -6 -387. ture as the 200 °F sprinkler (i.e., Specify: W -Type 7 Sprinkler Wrench, 150 °F). P/N 56- 850 -4 -001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446