Correspondence �S' Information
iit2M.To Build On
Engineering • Consulting • Testing ��>it- - S
November 10, 1999
Mr. John Maikos
James Barb Construction
5909 Woodford Drive NE
Albequerque, New Mexico 897110
Subject: Final Summary Report
Space C -7, Washington Square
PSI Project No. 702 -90410
Dear Mr. Piazza:
Professional Service Industries, Inc. (PSI) is writing this letter to document that, in accordance with Section 1701
of the State Building Code representative(s) from our firm have performed special inspection during construction for
the following project:
Permit No: BUP -99 -00360
Project Address: Space C -7, Washington Square
Project Description: Walking Company
Special Inspection(s) have included:
•
♦ Structural Steel inspection at site. Could not verify 5/8" diameter anchor bolts due to
accessibility. Received Engineers approval for as -built attachments.
To the best of our knowledge, the special inspections referenced herein were performed by our firm in general
accordance with the requirements, approved plans and specifications, provided change orders that impacted plans
and/or specifications, and applicable workmanship provisions of the State Building Code and Standards.
If you have any questions or we can be of further assistance, please do not hesitate to call.
Sincerely,
Professional Service Industries, Inc.
William M. Cantrell es L. Ellis, Sr.
Construction Services Manager Agency Manager
c: R. Bolen
Professional Service Industries, Inc. • 6032 N. Cutter Circle, Suite 480, P.O. Box 17126 • Portland, OR 97217 • Phone 503/289 -1778 • Fax 503/289 -1918
0/3 f/r/-q
, Ate.
August 25, 1999 • * ;� 4 � i
CITY OF TIGARD
David A. Udkow OREGON
9750 N. 96th St #219
Scottsdale, AZ 85258
RS: The Walking Co. Building Plan Review
9685 SW Washington Sq. Rd.
PC#: 8 -36c BUP#: 99.00360
Occupancy: M/S2 Occupant Load: 60
Submittal documents for the above referenced project have been reviewed for
conformance with the applicable 1998 Oregon Specialty Codes and other applicable •
codes and standards. The following comments are noted:
S r 5 ti evl 1. The cash wrap shall comply with OSSC, Section 1109.23.2 (36' long and not
more than 36" above finished floor).
A ? P µ --r — -- - •
1. Your lighting budget exceeds the allowable under OSSC, Table 13-P.
h t The allowable Including track lighting is as follows: p 5e e S .) (a) M = 1710 s.f. x 3.4w = 5814 watts
A-3 f (b) S = 655 s.f. x 1.0w = 655 watts Pe
Total allowable 6489
1. The storage area shall be separated from the "M' occupancy by one -hour
construction, OSSC; Table 3-B. Openings shall be protected by one -hour
eg 7 . t construction, OSSC, Section 302.3(4). Doors shall comply with OSSC, Section
' 713, Provide details. • .
,►� . I ti Jf`
it FA I 5 2. Door labeled #2 shall comply with OSSC. Section 1004.3.4.3.2.1. Provide
l" P - � uU . details.
•
1. Provide seismic attachment and calculations for storage shelving.
2. Provide structural calculations on new store front.
NAfe p
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TOD (503) 684-2772
Z00 /T00 m Q1IF'9I.L 30 .[.I,ID L6UL t99 COSH 9C : TT 66/9Z/9O
11
The Walking Co. Building Plan Review
PC#_ 8-35c BUDS: 99-00360
Page 82 � —
'14;17
Mechanical, plumbing and sprinkler systems require separate permits and applications.
Please submit two copies of revised submittal documents and a letter indicating your
response to the above comments for review. Please call me at (503) 839 -4171 if you
have any questions.
•
Sincerely,
Rdbe Poskin, CBO
SENIOR PLANS EXAMINER
ZOO,d00Eti auvp . 30 .UID LBZL TBQ ZOOM RC:TT aa,a .on