Loading...
Specifications 95 FS/ /,t . . . Rol" 3 g' a6o J 6o 4 [ Bulletin 136 Rev M r del F1 FR CO Ile I Tab � < ®1_ odel F1 FR Recessed � - 16 200�uick Response r�lki� inklers 5 DJ Model F1FR Sprinkler Types BAD I ► . - IN Standard Upright 4T if=_ - Standard Pendent ti ' a f t r ° fi Conventional r, Vertical Sidewalk I #' Horizontal Sidewall , ,' — HSW 1 Deflector - `_' 1 ; = x Model Fl FR Recessed Sprinkler Types : : — Recessed Pendent Upright Pendent Recessed Horizontal Sidewall — HSW 1 Deflector Listings & Approvals , w i , 1. Listed by Underwriters Laboratories, Inc. (UL) ,. \ 2. Listed by Underwri Laboratories of Canada (ULC) I ,'. 3. Certified by FM Approvals t ii 4. Loss Prevention Council (LPC, UK) } ,:, 5. NYC BS &A No. 587 -75 -SA l ` , J;;,...-.( ;', 4714),,t 6. Meets MIL- S -901C and MIL -STD 167 -1 .. `'. : :: 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258 -93-E - UL Listing Category Vertical Sidewall Conventional Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV , ` =T ,y ' / Patents: US Patent No 6,374,920 Applies to k ( 1I 1 1, " I � 5 Model Fl FR Vertical Sidewall Sprinklers. , Product Description Horizontal Sidewall Recessed Pendent Reliable Models F1FR and F1FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown) I quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. pands, forcing the bubble smaller and smaller as the liquid The Models F1 FR and Fl FR Recessed automatic sprinklers pressure increases. Continued heating forces the liquid to utilize a 3.0 mm frangible glass bulb. These sprinklers have push out against the bulb, causing the glass to shatter, demonstrated response times in laboratory tests which are opening the waterway and allowing the deflector to distrib- five to ten times faster than standard response sprinklers. This ute the discharging water. quick response enables the Model F1 FR and Fl FR Recessed sprinklers to apply water to a fire much faster than standard Application sprinklers of the same temperature rating. Quick response sprinklers are used in fixed fire protec- The glass bulb consists of an accurately controlled amount ton systems: Wet, Dry, Deluge or Preaction. Care must be - of special fluid hermetically sealed inside a precisely manu- exercised that the orifice size, temperature rating, deflector factured glass capsule. This glass bulb is specially con- style and sprinkler type are in accordance with the latest structed to provide fast thermal response. The balance of published standards of the National Fire Protection Asso- parts are made of brass, copper and beryllium nickel. ciation or the approving Authority Having Jurisdiction. At normal temperatures, the glass bulb contains the fluid Quick response sprinklers are intended for installation as in both the liquid and vapor phases. The vapor phase can specified in NFPA 13. Quick response sprinklers and stan- be seen as a small bubble. As heat is applied, the liquid ex- dard response sprinklers should not be intermixed The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type K Factor Sprinkler Approval Sprinkler Identification Standard - Upright (SSU) and Pendent (SSP) Number (SIN) Deflectors Marked to Indicate Position US Metric Height Organization SSU SSP )2" (15mm) Standard Onfice with y," NPT (R/ Thread 5.6 80 2 2" (56mm) 12,3,4,5,6,7 R3625 R3615 %" (20mm) Large Orifice with y;" NPT (R /n)Thread 8.0 115 2 3" (58mm) 1,2,3,4, 7,8 R3622 R3612 ," (17mm) Small Orifice with /2" NPT (R)2) Thread 4 2 60 22' (56mm) 12,8 R3623 R3613 %" (10mm) Small Orifice with ," NPT (R)y) Thread 2 8 40 2.2" (56mm) 1,2,8 R3621 R3611 10mm Orifice XU with R /" Thread 4 2 60 56mm 4,6,7 R3624 R3614 Conventional - Install in Upright or Pendent Position 10mm Orifice XL H with R% Thread 4 2 60 56mm R3674 15mm Standard Orifice with Jr NPT (R)) Thread 5 6 80 56mm 4,6,7 R3675 20mm Large Onfice with 3 /4" NPT (R 8 0 115 58mm 4,7 R3672 ' Sit -' ...,', , a ft' 111,43 / �� j , kt. ■ f .r I {i xis T�' ;} , 1 Upright Pendent Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler I Installation Wrench: Model GFR1 Sprinkler Wrench - Installation Data: Nominal Thread K Factor Sprinkler Approvarl Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) X (15mm) )2" NPT (RY2) 5.6 80 2 2" (56mm) 1,2,3,4,5,7,8 R3615 1732" (20mm) X," NPT (RN) 8 0 115 2 3" (58mm) 1,2,3,8 R3612 T 6 (11 mm) )2" NPT (R1) 4.2 60 2.2" (56mm) 1,2,8 R3613 %" (10mm) )z" NPT (R1/2) 2 8 40 2.2" (56mm) 1,2,8 R3611 lomm R% 4 2 60 56mm 4,7 R3614 t1 l Refer to escutcheon data table for approvals and dimensions 2 1 /4' HOLE D - 2 5 /8" D/A [66.7mm] 157 .2 HOLE IN CEILING 7 75/76" WA + 1 5/16" DIA [5B.7mm] � [ <0 2mm] ] / CUP / ti i I L =- l_ _I I =� _� __�� TURN CO//AR — — I X 1/2' REDUCER f I 1 X 1/2" REDUCER UNTIL OGHT 1 AGAINST SPRINKLER WRENCH BOSS \ / I I \\ / I r I _ 47. ��, Fact OF F/RrNC 70 r'� CEILING L J ADJUSTMENT ( ' I C CEILING D/NENS/ON �j1���� �� 1 i O = =i:i FACE OF FITTING \ I TO FACE OF CEILING 1 /6" k\ , `\ ir � DIMEN$l0N [l.1mm] t I u. rU A _ A" (I) 2 17/51' D ADJUSTMENT [72.1mm] 1.36F00 :_e -- --- l6F005_1 (1) REFER TO FI & F2 ESCUTCHEON DATA TABLE F04 APPROVALS AND DIMENSIONS (1) REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS 2. Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: K Factor Sprinkler Nominal Thread Sprinkler Approval Identification - Orifice Size US Metric Height Organizations Number (SIN) 1/2" 1/2" NPT (R1/2) 5.6 80 2 2" (56mm) 1, 2, 3, 6, 8 R3685 15mm /2" NPT (R1/2) 5 6 80 2 2" (56mm) 4 (1) (1) LPC Approval is for Pendent position only -T �, Orientation Deflector to Ceiling •,° • Dimension (Min. - Max.) (4(4,-.1.: Upright 4" - 12" (102mm - 305mm) Pendent 6" - 12" (152mm - 305mm) Vertical Sidewall I US Patent No. 6,374,920 Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations K Factor and Type of Approval Sprinkler Nominal Thread Sprinkler Identification Light Ordinary Number (SIN) Orifice Size US Metric Length Hazard Hazard ,1" (15mm) J2" NPT(R%) 5 6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with Fl or F2 recessed escutcheon. 136FG04 / / / /14 / 1 ii � ..� { ( WALL AF tti' - -- Sal :. ' " FA L TO 1 1/4" MIN .5 i. 4 1 "L 'M,,;. 'r"" 1T ' ' ..,. ' (31, Bmm] . et P ,� 7r � • v' �t,,), 2 1/4 VOLE D✓1 �1111, . Zy fr .i s ® ^, V . . r ' ti { ' (57 ?mm] (3 [ " m m ] 11 r6mm- 1524mmJ i CEILING TO ' d 1e / 1 ' Y. 1/2" REDUCER / DEFLECTOR ; , I AN J 1 15/16 014 `fl�l � Horizontal Sidewall Tog 2mm] ; Till* , 2 27/32 D1A 1 mc r _iA� (72.2mm] TURN COLLAR UNTIL ,, 1 T/ HT AGAINST SPRINKLER WRENCH 5055 L, AUJUS (1) (1) REFER TO ESCU'HCEON DATA TABLE FOR APPROVALS AND DIMENSIONS 3. Installation Quick response sprinklers are intended for installation as cleaning fluids. Remove dust by using a soft brush or gen- specified in NFPA 13. Quick response sprinklers and Stan- tie vacuuming. Remove any sprinkler which has been dard response sprinklers should not be intermixed painted (other than factory applied) or damaged in any The Model Fl FR Recessed Quick Response Sprinklers are to way. A stock of spare sprinklers should be maintained to be installed as shown. The Model Fl or F2 Escutcheons illus- allow quick replacement of damaged or operated sprin- trated are the only recessed escutcheons to be used with the klers. Prior to installation, sprinklers should be maintained - Model Fl FR Sprinklers. The use of any other recessed escutch- in the original cartons and packaging until used to mini- eon will void all approvals and negate all warranties. mize the potential for damage to sprinklers that would When installing Model Fl FR Sprinklers, use the Model D Sprin- cause improper operation or non -operation. kler Wrench. When installing Model Fl FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any Sprinkler Types other type of wrench may damage these sprinklers. Standard Upright Glass bulb sprinklers have orange bulb protectors to minimize Standard Pendent bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER Conventional SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- Sidewall (Vertical, Horizontal HSW1) moval of the protectors before this time may leave the bulb vul- Recessed Pendent nerable to damage. RASCO wrenches are designed to install Recessed Horizontal Sidewall HSW1 sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Finishes (1) (2 ' TO REMOVE THE PROTECTORS. Standard Finishes Sprinkler Escutcheon Temperature Ratings Bronze Brass Sprinkler Chrome Plated Chrome Plated (3) Classification Temperature Max Ambient Bulb °C °p Temp. Color White Polyester Coated White Painted (3) Ordinary 58 155 100°F (38°C) Orange Special Application Finishes Ordinary 68 155 100°F (38°C) Red Sprinkler Escutcheon Intermediate 79 175 153°F(66°C) Yellow Bright Brass Bright Brass Intermediate 93 200 150 °F(66°C) Green High (t) 141 286 225 °F(107°C) Blue Black Plated Black Plated Black Paint Black Paint (1) Not available for recessed sprinklers. Off White Off White Escutcheon Data Satin Chrome Satin Chrome Escutcheon of R ( Other finishes and colors are available on special order Face model Approvals Acqustrrrerrt Dimension to Cam cc Consult the factory for details Wall Dimension ( FM Approvals is limited to bronze and brass, chrome or black 1y " plated finishes only Max Recess (38.1mm) % " -1%fi" ( FP Push - on/Thread -off escutcheon Fl 1,2,4,8 Min Recess 3 a / ' (5mm - 24mm) (19.1mm) Ordering Information y S Specify: Max Recess (38.1mm) ' /,s" yfi' P fY F2 1,2,3,4,5,7,8 Min Recess iy, " (5mm -17mm) 1. Sprinkler Model (24mm) 2. Sprinkler Type FP 1,2 Max Recessed 7/16" 1 (381mm) 3. Orifice Size Push-on/ (11 mm) 4. Deflector Type Thread-off 1,2 Min Recessed 15/16 1 " (25.4mm) (24mm) 5. Temperature Rating No Dimensional Figure for FP 6. Sprinkler Finish 7. Escutcheon Type Maintenance 8. Escutcheon Finish (where applicable) The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system Note: When Model F1FR Recessed sprinklers are maintained in accordance with NFPA 25. Do not clean ordered, the sprinklers and escutcheons are packaged sprinklers with soap and water, ammonia or any other separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries Manufactured by The Reliable Automatic Sprinkler Co., Inc. ® R i ayp Recycled Reliable:3 (800)431 -1588 Sales Offices (800)848 -6051 Sales Fax (914)668 -3470 Corporate Offices Revision lines indicate updated or new data www reliablesprinkler com Internet Address EG Printed in U S A 7/05 P/N9999970027 t qco /Ffre & Building Products CENTRAL Customer Service/Sales: Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Tel: (215) 362 -0700 / (800) 523 -6512 Fax: (215) 362 -5385 Series TY -FRB — 2.8, 4.2, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General mospheres. Although corrosion resis- tant coated sprinklers have passed the 1 standard corrosion tests of the appli- -- Description cable approval agencies, the testing is = r . s 772. not representative of all possible cor- The Series TY-FRB, 2.8, 4.2, 5.6, and rosive atmospheres. Consequently, it - it 8.0 K- factor, Upright and Pendent is recommended that the end user be 9 Sprinklers described in this data sheet consulted with respect to the suitability i lit i are quick response - standard cover- of these coatings for any given corro- age, decorative 3 mm glass bulb type sive environment. The effects of ambi- spray sprinklers designed for use in ent temperature, concentration of light or ordinary hazard, commercial chemicals, and gas /chemical velocity, — s::s;' occupancies such as banks, hotels, should be considered, as a minimum, "" x ' - shopping malls, etc. along with the corrosive nature of the , The recessed version of the Series chemical to which the sprinklers will be TY-FRB Pendent Sprinkler, where ap- exposed. plicable, is intended for use in areas An intermediate level versions of the — with a finished ceiling. It uses either a Series TY -FRB Pendent Sprinklers are two -piece Style 10 (1/2 inch NPT) or detailed in Technical Data Sheet , -"'''7- Style 40 (3/4 inch NPT) Recessed Es- TFP356, and Sprinkler Guards are de- f fir - ) cutcheon with 1/2 inch (12,7 mm) of tailed in Technical Data Sheet TFP780 A I recessed adjustment or up to 3/4 inch _ (19,1 mm) of total adjustment from the WARNINGS >�4 I . flush pendent position, or a two -piece The Series TY -FRB Sprinklers de- Style 20 (1/2 inch NPT) or Style 30 (3/4 scribed herein must be installed and '�..�"� _ inch NPT) Recessed Escutcheon with maintained in compliance with this -.I'.1 -" 1/4 inch (6,4 mm) of recessed adjust- document, as well as with the applica- ' ment or up to 1/2 inch (12,7 mm) of ble standards of the National Fire Pro - TY3231 - Pendent 5.6K,1/2 "NPT total adjustment from the flush pen- tection Association, in addition to the TY4131 - Upright 8.0K, 3/4 "NPT dent position. The adjustment provided standards of any other authorities hav- TY4231 - Pendent 8.0K, 3/4 "NPT by the Recessed Escutcheon reduces ing jurisdiction. Failure to do so may the accuracy to which the fixed pipe impair the performance of these de- drops to the sprinklers must be cut. vices. Technical Corrosion resistant coatings, where The owner is responsible for maintain- applicable, are utilized to extend the ing their fire protection system and de- Data life of copper alloy sprinklers beyond vices in proper operating condition. that which would otherwise be ob- The installing contractor or sprinkler Approvals tained when exposed to corrosive at- manufacturer should be contacted UL and C-UL Listed. with any questions. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval IMPORTANT information including corrosion resis- Always refer to Technical Data tant status.) Sheet TFP700 for the "INSTALLER Model /Sprinkler Maximum Working Pressure . WARNING" that provides cautions - - 175 psi (12,1 bar) with respect to handling and instal- Identification lation of sprinkler systems and corn- Discharge Coefficient ponents. Improper handling and in- Numbers K = 2.8 GPM /psi (40,3 LPM/bar / stallation can permanently damage K = 4.2 GPM /psi (60,5 LPM/barl / a sprinkler system or its compo- TY1131 - Upright 2.8K, 1/2"NPT K = 5.6 GPM /psi / (80,6 LPM/bar / nents and cause the sprinkler to fail TY1231 - Pendent 2.8K, 1/2"NPT K = 8.0 GPM /psi (115,2 LPM /bar to operate in a fire situation or cause TY2131 - Upright 4.2K, 1/2 "NPT Temperature Ratings it to operate prematurely. TY2231 - Pendent 4.2K, 1/2"NPT Refer to Table A and B TY3131 - Upright 5.6K,1/2 "NPT Page 1 of 8 JULY, 2004 TFP171 Page 2 of 8 TFPI 71 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED SURFACE NPT MAKE-IN ESCUTCHEON DEFLECTOR , i 5 7/1 i i 1 . r =� m 2 -1/4" — 1 - � A� 'W 1 M NAL I i 4 - (57,2 mm) 1 — NOMI NAL w MAK -IN ' 2 1-9/16" I IMO f (5 6 mm) d i g 3 11 � \ (39,7 mm) CH Ai 111 . S iireti�� �ren � � t yam 7 SSP DEFLECTOR * 2 -7/8" (73,0 mm) DIA. 1/2" NPT f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16° (11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED SURFACE NP MAKE-IN ESCUTCHEON DEFLECTOR 6 , 1./ 5 2-3/16" — 1 - 'Err-. 7/16" ) I (55,6 mm) �� � — NOMINAL ' 4 �1� MAKE IN 1-1 I �/ 23/16" 2 (38,1 mm) 1I rp v WRENCH l (55,6 mm) 0 y 9. II .. . FLATS _ _ ' jam} ' 3 SSP DEFLECTOR * - 2 -7/8" (73,0 mm) DIA. --- -1 1/2" NPT I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K- FACTOR, 1/2 INCH NPT co Finishes Bulb Glass v Sprinkler: Refer to Table A and B Compression Screw Bronze Operation E Recessed Escutcheon: White Coated, Deflector ... .. Copper /Bronze I- Chrome Plated, or Brass Plated Bushing (K =2.8) Bronze The glass Bulb contains a fluid which m expands when exposed to heat. When y Physical Characteristics the rated temperature is reached, the 'm Frame Bronze fluid expands sufficiently to shatter the ii Button Brass /Copper glass Bulb, allowing the sprinkler to 0 a and water to flow. Sealing Assembly o Beryllium Nickel w/Teflont } TFP171 Page 3 of 8 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED SURFACE NPT MAKE -IN ESCUTCHEON P DEFLECTOR 7/1 '�' 5 I If= 2 3/16" � _ I ( 11,1 mm) I (55,6 mm) 1 I =1 � �A NOMINAL ; 4 7 MAK -IN , (38,1 1-1/2" mm) I rj I , 11 1 2- 3/16" ,Q� 'D 2 WRENCH 1 (55,6 m m) , 3 FLATS SSP DEFLECTOR * - 2 -7/8" (73,0 mm) DIA. , 1/2 "NPT ** f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2" (12,7 mm) STYLE 30 or 40 PLATE SEATING ** NOMINAL RECESSED SURFACE NPT MAKE -IN ESCUTCHEON DEFLECTOR 6 * i — ?7T ,r` * , 1/2" 5 2-5/16" ! � 1 � (12,7 mm) I 4 (58,7 mm) i r ���` I NOMINAL I 1 1 L ���1 MAKE -IN h 1-9/16" I li WRENCH 1121116161111 2 -1/4" 4 V ii 1,- 2 (39,7 mm) (57,2 mm) - 1 1 • _.. - -- 11 -- • FLATS . 3 44 i SSP DEFLECTOR * f— 2 -7/8" (73,0 mm) DIA. 3/4" NPT f PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT Listing is based on the requirements of Design NFPA 13, and FM Approval is based Installation on the requirements of FM's Loss Pre - Criteria vention Data Sheets ). Only the Style The Series TY-FRB Sprinklers must be 10, 20, 30, or 40 Recessed Escutch- installed in accordance with the follow- - The Series TY-FRB Pendent and Up- eon, as applicable, is to be used for ing instructions: right Sprinklers are intended for fire recessed pendent installations. protection systems designed in ac- NOTES cordance with the standard installation Do not install any bulb type sprinkler if rules recognized by the applicable the bulb is cracked or there is a loss of Listing or Approval agency (e.g., UL liquid from the bulb. With the sprinkler Page 4 of 8 TFP171 SPRINKLER FINISH (See Note 7) inch NPT sprinkler joint should be ob- K TYPE TEMP. BULB NATURAL CHROME WHITE"' tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 LIQUID BRASS PLATED POLYESTER ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- . 135°F/57°C Orange nections. Higher levels of torque may PENDENT 155 °F /68 °C Red distort the sprinkler inlet and cause (TY1231) 1, 2, 3, 5 leakage or impairment of the sprinkler. and 175 °F /79 °C Yellow Do not attempt to make -up for insuffi- UPRIGHT 200 °F /93 °C Green 1) cient adjustment in the escutcheon 2.8 286 °F /141 °C Blue plate by under- or over - tightening the 1/2" sprinkler. Readjust the position of the NPT 135 °F /57 °C Orange sprinkler fitting to suit. RECESSED 155 °F /68 °C Red PENDENT The Series TY - FRB Pendent and Up (TY1231)• 175 °F /79 °C Yellow right Sprinklers must be installed in Figure 5 accordance with the following instruc- 200 °F /93 °C Green 1, 2, 5 tions. 135 °F /57 °C Orange Step 1. Pendent sprinklers are to be RECESSED 155 °F /68 °C Red installed in the pendent position, and PENDENT upright sprinklers are to be installed in (TY1231)" 175 °F /79 °C Yellow the upright position. Figure 6 200 °F /93 °C Green Step 2. With pipe thread sealant ap- 135 °F /57 °C Orange plied to the pipe threads, hand tighten PENDENT the sprinkler into the sprinkler fitting. 155°F/68°C Red (TY2231) Step 3. Tighten the sprinkler into the and 175 °F /79 °C Yellow sprinkler fitting using only the W -Type UPRIGHT 200 °F /93 °C Green 6 Sprinkler Wrench (Ref. Figure 13). 4 2 (TY2131) With reference to Figures 1, 2, 3, and 4.2 286 °F /141 °C Blue 1 2 4, the W -Type 6 Sprinkler Wrench is to NPT 135 °F /57 °C Orange be applied to the sprinkler wrench RECESSED flats. PENDENT 155 F /68 °C Red (TY2231)• 175 °F /79 °C Yellow The Series TY - FRB Recessed Pen - Figure 7 200 °F /93 °C Green dent Sprinklers must be installed in accordance with the following instruc- 135°F/57°C Orange tions. RECESSED 155 °F /68 °C Red Step A. After installing the Style 10. PENDENT (TY2231)» 175 °F /79 °C Yellow 20, er Mounting Plate, as cable, , ovyer r the sprinkler threads and and Figure 8 200 °F /93 °C Green with pipe thread sealant applied to the ' - pipe threads, hand tighten the sprin- NOTES: kler into the sprinkler fitting. 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Step B. Tighten the sprinkler into the 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response sprinkler fitting using only the W-Type P 9 9 Y YP e 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin 7 Recessed Sprinkler Wrench (Ref. klers. Figure 14). With reference to Figure 1, 5. Approved by the City of New York under MEA 354 -01 -E. 2, 3, and 4, the W -Type 7 Recessed 7. Where Polyester Coated Sprinklers are noted to be UL and C -UL Listed, the sprin- Sprinkler Wrench is to be applied to kiers are UL and C-UL Listed as Corrosion Resistant Sprinklers. the sprinkler wrench flats. * Installed with Style 10 (1/2° NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Step C. After the ceiling has been in- Recessed Escutcheon, as applicable. stalled or the finish coat has been ap- ** Installed with Style 20 (1/2° NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment plied, slide on the Style 10, 20, 30, or Recessed Escutcheon, as applicable. 40 Closure over the Series TY FRB °" Frame and Deflector only. Listings and approvals apply to color (Special Order). Sprinkler push the Closure over and N/A: Not Available P P the Mounting Plate until its flange TABLE A comes in contact with the ceiling. LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K- FACTOR SPRINKLERS held horizontally, a small air bubble A leak tight 1/2 inch NPT sprinkler joint should be present. The diameter of the should be obtained with a torque of 7 air bubble is approximately 1/16 inch to 14 ftlbs. (9,5 to 19,0 Nm). A maxi - (1,6 mm) for the 135 °F /57 °C to 3/32 mum of 21 ft. lbs. (28,5 Nm) of torque inch (2,4 mm) for the 286 °F /141 °C may be used to install sprinklers with temperature ratings. 1/2 NPT connections. A leak tight 3/4 TFP171 Page 5 of 8 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LEAD LIQUID BRASS PLATED POLYESTER COATED 135 °F /57 °C Orange PENDENT Red and 175 °Fl79 °C Yellow 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 • UPRIGHT 200 °F /93 °C Green 5.6 (TY3131) 286 °F /141 °C Blue 1/2" NPT 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 4, 5 N/A (TY3231)* 175 °F /79 °C Yellow Figure 9 200 °F /93 °C Green 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 1, 2, 4, 5 N/A (TY3231)** 175 °F /79 °C Yellow Figure 10 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red and 175 °F /79 °C Yellow 1, 2, 5 1,2,3,4,5,6,7 UPRIGHT 200 °F /93 °C Green 8.0 (TY4131) 286 °F /141 °C Blue 3/4° NPT 135 °F /57 °C Green RECESSED 155 °F /68 °C Orange PENDENT 1, 2, 4, 5 N/A (TY4231)* 175 °F /79 °C Red Figure 11 200 °F /93 °C Yellow 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1,2,3,4,5 N/A (TY4231)** 175 °F /79 °C Yellow Figure 12 P00 °F /93 °C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31 -53- 428- 4444/Fax 31- 53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. • Installed with Style 10 (1/2° NPT) or Style 40 (3/4" NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2° NPT) or Style 30 (3/4" NPT) 1/2° Total Adjustment Recessed Escutcheon, as applicable. * ** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K- FACTOR SPRINKLERS Page 6 of S TFP171 2 -7/8° DIA. 2 -7/8' DIA. _ 5/8±1/4° (73,0 mm) 3/4' (19,1 mm) 1/2±1/8° (73,0 mm) 1/2' (12,7 mm) (15,9±6,4 mm) 2 -1/4° DIA. 1/4'(6,4 mm) (12,7±3,2 mm) 2 -1/4' DIA. 1/4° (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8° 1/8° •� (3 ,2 mm) •� (3,2 mm) ll�l��� 7 w ,� tip- i f � MOUNTING IN MOUNTING SURFACE . SURFACE 1 wr CLOSURE SERIES 1 -5/16° (33,3 mm) CLOSURE SERIES 1 -5/16° (33,3 mm) TY-FRB 13/16° (20,6 mm) TY-FRB 1 -1/16' (27,0 mm) FIGURE 5 FIGURE 6 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K- FACTOR, 1/2 INCH NPT 2.8 K- FACTOR, 1/2 INCH NPT 2 -7/8° DIA. _ 2 -7/8° DIA. _ 5/8±1/4° (73,0 mm) 3/4° (19,1 mm) 1/2±1/8° (73,0 mm) 1/2° (12,7 mm) (15,9±6,4 mm) 2 -1/4° DIA. 1/4° (6,4 mm) (12,7±3,2 mm) 2 -1/4' DIA. 1/4° (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" I 1/8' 11Hf ( mm) r 1 ��� i /i' 1/8' (3,2 ■ i l l r yy. lil �, SURFACE 111/ MOUNTING II . SURFACE - .. CLOSURE SERIES 1 -1/4° (31,8 mm) CLOSURE SERIES 1 -1/4" (31,8 mm) TY-FRB 3/4' (19,1 mm) T -FRB 1° (25,4 mm) FIGURE 7 FIGURE 8 SERIES TY-FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K- FACTOR, 1/2 INCH NPT 4.2 K- FACTOR, 1/2 INCH NPT /� used to cover a clearance hole, may and after installation. Sprinklers dam - Care and delay the time to sprinkler operation in aged by dropping, striking, wrench Mai a fire situation. twist/slippage, or the like, must be re- ntenance Sprinklers that are found to be leaking has a cracked p bulb o has lost The Series TY-FRB Sprinklers must be or exhibiting visible signs of corrosion liquid from its bulb. (Ref. Installation maintained and serviced in accord- must be replaced. Section). ance with the following instructions: Automatic sprinklers must never be Frequent visual inspections are rec- painted, plated, coated or otherwise ommended to be initially performed for NOTES altered after leaving the factory. Modi- Before closing a fire protection system fied sprinklers must be replaced. corrosion resistant coated sprinklers, main control valve for maintenance Sprinklers that have been exposed to after the installation has been corn- work on the fire protection system that corrosive products of combustion, b pleted, to verify the integrity of the cor- it controls, permission to shut down the have not operated, should be replaced rosion resistant coating. Thereafter, • affected fire protection system must be if they cannot be completely cleaned annual inspections per NFPA 25 obtained from the proper authorities by wiping the sprinkler with a cloth or should suffice; however, instead of in- and all personnel who maybe affected by brushing it with a soft bristle brush. specting from the floor level, a random by this action must be notified. sampling of close -up visual inspec- Care must be exercised to avoid dam- tions should be made, so as to better Absence of an escutcheon, which is age to the sprinklers - before, during, determine the exact sprinkler condi- TFP779 Page 7 of S 2 -7/8° DIA. 2 -7/8" DIA. 5/8±1/4" (73,0 mm) 3/4° (19,1 mm) 1/2±1/8' (73,0 mm) 1/2° (12,7 mm) (15,9±6,4 mm) 2 -1/4° DIA. 1/4' (6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4° (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8° 1/8" ��' (3,2 mm) 'a ) , 1 � ' , (3,2 mm 114 , 7i,__� % / /,' _■ �1J Itg MOUNTING �� SURFACE IIP Nil SURFACE _ =.;- '__-- i CLOSURE SERIES 1 -1/4' (31,8 mm) CLOSURE SERIES 1 -1/4° (31,8 mm) TY -FRB 3/4° (19,1 mm) TY-FRB 1° (25,4 mm) FIGURE 9 FIGURE 10 SERIES TY-FRB RECESSED PENDENT SERIES TY -FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT 5.6 K- FACTOR, 1/2 INCH NPT 2 -7/8° DIA. 2 -7/8° DIA. 5/8 ±1/4° (73,0 mm) 3/4' (19,1 mm) 1/2±1/8" (73,0 mm) 1/2° (12,7 mm) (15,916,4 mm) 2 -1/4° DIA. 1 1/4° (6,4 mm) (12,7±3,2 mm) 2 -1/4° DIA. 1/4' (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57 2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8° I 1/8° � (3,2 mm) " (3,2 mm) NS . ■II iir� frl -- � �.• P. I \ f '�. MOUNTING If MOUNTING f SURFACE SURFACE 1 111 , CLOSURE SERIES 1 -5/16° (33,3 mm) CLOSURE SERIES 1 -5/16° (33,3 mm) TY-FRB 13/16' (20,6 mm) TY-FRB 1 -1/16° (27,0 mm) FIGURE 11 FIGURE 12 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT 8.0 K- FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may ! WRENCH be affected by the corrosive conditions �+' RECESS present. WRENCH RECESS OP- The owner is responsible for the in- (END °A° USED FOR r+ spection, testing, and maintenance of 1/2° NPT MODELS) J� / , their fire protection system and de- � � 1 vices in compliance with this docu- ment, as well as with the applicable .°., standards of the National Fire Protec- WRENCH RECESS tion Association (e.g., NFPA 25), in (END °B° USED FOR PUSH WRENCH 3/4° NPT MODELS) IN TO ENSURE addition to the standards of any other ENGAGEMENT authorities having jurisdiction. The in- WITH SPRINKLER stalling contractor or sprinkler manu- FIGURE 13 WRENCHING AREA facturer should be contacted relative to W - TYPE 6 SPRINKLER any questions. WRENCH It is recommended that automatic FIGURE 14 sprinkler systems be inspected, local requirements and /or national W - TYPE 7 RECESSED tested, and maintained by a qualified codes. SPRINKLER WRENCH Inspection Service in accordance with Page 8 of 8 TFPI 71 P/N 57 -XXX -X -XXX I I . TEMPERATURE MODEUSIN RATING SPRINKLER - 330 2.8K UPRIGHT (1 /2 "NPT) TY1131 135 135 °F /57 °C 331 2.8K PENDENT (1 /2 "NPT) TY1231 1 NATURAL BRASS 155 155 °F /68 °C 340 4.2K UPRIGHT (1 /2 "NPT) TY2131 4 WHITE POLYESTER 175 175 °F /79 °C 341 4.2K PENDENT (1 /2 "NPT) TY2231 3 WHITE (RAL9010)' 200 200 °F /93 °C 370 5.6K UPRIGHT (1 /2 °NPT) TY3131 9 CHROME PLATED 286 286 °F /141 °C 371 5.6K PENDENT (1 /2 "NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT (3/4 "NPT) TY4131 391 8.0K PENDENT (3/4 "NPT) TY4231 • Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS ORY, FOR INCIDENTAL, INDIRECT, Recessed Escutcheon: Limited SPECIAL OR CONSEQUENTIAL Specify: Style (specify) Recessed Es- DAMAGES, INCLUDING BUT NOT cutcheon with (specify finish), P/N Warranty LIMITED TO LABOR CHARGES, RE- (specify). GARDLESS OF WHETHER TYCO Products manufactured by Tyco Fire FIRE PRODUCTS WAS INFORMED 1/2' (15 mm) Products are warranted solely to the ABOUT THE POSSIBILITY OF SUCH Style 10 original Buyer for ten (10) years DAMAGES, AND IN NO EVENT Chrome Plated P /N56- 701 -9-010 against defects in material and work- SHALL TYCO FIRE PRODUCTS' LI- White Coated P/N 56 -701 -4 -010 manship when paid for and properly ABILITY EXCEED AN AMOUNT Br Plated s Plated 0' P /N5 701 -3010 Br P/N 56- 701 -2 -010 installed and maintained under normal EQUAL TO THE SALES PRICE. use and service. This warranty will ex- THE FOREGOING WARRANTY IS 1/2° (15 mm) pire ten (10) years from date of ship- MADE IN LIEU OF ANY AND ALL Style 20 ment by Tyco Fire Products. No war- Chrome Plated P/N 56- 705 -9-010 ranty is given for products or OTHER WARRANTIES EXPRESS OR White Coated P/N 56-705-4-010 components manufactured by compa- IMPLIED, INCLUDING WARRANTIES White RAL9010' P/N 56- 705 -3-010 Hies not affiliated by ownership with OF MERCHANTABILITY AND FIT- Brass Plated P/N 56- 705 -2-010 Tyco Fire Products or for products and NESS FOR A PARTICULAR PUR 3/4° (20 mm) components which have been subject POSE Style 30 to misuse, improper installation, corro- Chrome Plated P/N 56- 705 -9-011 sion, or which have not been Installed, White Coated P/N 56 -705 -4 -011 maintained, modified or repaired in ac- White Plated 0' P/N 56- 705 -3-011 cordance with applicable Standards of ac- Ordering Brass Plated P/N 56-705-2-011 the National Fire Protection Associa- Procedure 3/4° (20 mm) tion, and /or the standards of any other Style 40 Authorities Having Jurisdiction. Mate- 0rmitaratqgtio local distributor for avail- Chrome Plated P/N 56- 700 -9-010 rials found by Tyco Fire Products to be ability indicate the White Coated P/N 56- 700 -4-010 defective shall be either repaired or fu White RAL9010' P/N 56- 700 -3-010 replaced, at Tyco Fire Products' sole name. Refer to Brass Plated P/N 58 -700 -2 -010 option. Tyco Fire Products neither as- the Price List for o P Y complete listing 'Eastem Hemisphere sales only. sumes, nor authorizes any person to of Part Numbers. assume for it, any other obligation in Sprinkler Wrench: connection with the sale of products or Sprinkler Assemblies with NPT Specify: W -Type 6 Sprinkler Wrench, • parts of products. Tyco Fire Products Thread Connections: P/N 56- 000 -6 -387. shall not be responsible for sprinkler Specify: (Specify Model /SIN), Quick system design errors or inaccurate or Response, (specify K- factor), (specify Specify: W -Type 7 Sprinkler Wrench, incomplete information supplied by temperature rating), Series TY-FRB P/N 56 -850 -4 -001. - Buyer or Buyer's representatives. (specify Pendent or Upright) Sprinkler IN NO EVENT SHALL TYCO FIRE with (specify type of finish or coating), PRODUCTS BE LIABLE, IN CON- P/N (specify from Table C). TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE - TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446