Plans ? 577 4tJ P4 B ? 6. i - o ( o -c & Buildin Tyco IF/re Building Products „ . , 2006 - m Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 � L � J �� ��� 77) Series RFII — 5.6 K- factor "Royal Flush II" Pendent Concealed Sprinklers Quick & Standard Response, Standard Coverage General Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the Mak Description sprinkler while the ceiling is being in- stalled or finished. The tip of the Pro- The Series RFII Quick Response tective Cap can also be used to mark _.- (3 mm bulb) & Standard Response (5 the center of the ceiling hole into plas- - _ . mm bulb), 5.6 K- Factor, "Royal Flush ter board, ceiling tiles, etc. by gently II" Concealed Pendent Sprinklers are pushing the ceiling product against the ;�:--- decorative sprinklers featuring a flat Protective Cap. When the ceiling in- cover plate designed to conceal the stallation is complete the Protective sprinkler. It is the best choice for archi- Cap is removed and the Cover Plate tecturally sensitive areas such as hotel Assembly installed. lobbies, office buildings, churches, As an option, the Series RFII Standard and restaurants. Response (5 mm bulb) "Royal Flush II" Each unit includes a Cover Plate As- Concealed Pendent Sprinklers may be sembly that conceals the sprinkler op- fitted with a silicone Air and Dust Seal UL, C -UL, and NYC. Maximum 175 erating components above the ceiling. (Ref. Fig. 5). The Air and Dust Seal is psi (12,1 bar) by FM. The separable two -piece design of the intended for sensitive areas where it is Cover Plate and Support Cup Assem- desirable to stop air and dust travel Technical blies allows installation of the sprin- through the cover plate from the area kiers and pressure testing of the fire above the ceiling. Data protection system prior to installation WARNINGS of a suspended ceiling or application of the finish coating to a fixed ceiling. The Series RFII Concealed Pendent Approvals for Series RFII They also permit removal of sus Sprinklers described herein must be UL and C -UL Listed. FM Approved. pended ceiling panels for access to installed and maintained in compli- NYC under MEA 353 -01 -E. LPCB (Ref. building service equipment without ante with this document, as well as No. 094a/ for TY3551 & 094a/10 for h g avin to first shut down the fire pro- with t h e applicable standards of the TY3531 A pproved. hav system and remove sprinklers. Nat Fire Protection Association, The approvals apply only to the serv- le two-piece in addition to the standards of any ice conditions indicated in the Design Also, the separab o piece design f the the Sprinkler provides o for ig n pi other authorities having jurisdiction. Criteria section and maximum pres- inch the th mm) of er for 1/2 Failure to do so may Impair the per- sure ratings indicated in the to reduce the accuracy to which the formance of these devices. Model /Sprinkler Identification Num- length of fixed pipe drops to the sprin- T owner is responsible for maintain- bers section. kiers must be cut. t rig their fire protection system and de- Approvals for Air & Dust Seal The Series RFII Sprinklers are vices in proper operating condition. (Part #10908100) shipped with a Disposable Protective are The installing contractor or sprinkler UL and C -UL Listed for use with the manufacturer should be contacted RFII (TY3551 & TY3504) Standard Re- with any questions. sponse Concealed Sprinkler. IMPORTANT Temperature Ratings Always refer to Technical Data Model /Sprinkler 155F/68C Sprinkler - 135F/57C Plate Sheet TFP700 for the "INSTALLER 200F/93C Sprinkler - 165F/74C Plate WARNING" that provides cautions Identification Discharge Coef with respect to handling and instal- K = 5.6 GPM /psi ' (80,6 LPM/bar /2 ) lation of sprinkler systems and corn- Numbers Adjustment ponents. Improper handling and in- 1/2 inch (12,7 mm) stallation can permanently damage TY3551 (5mm bulb) & TY3531 (3 mm Finishes a sprinkler system or its compo- bulb): maximum 175 psi (12,1 bar) by Cover Plate: Chrome Plated, Brass nents and cause the sprinkler to fail UL, C -UL, FM, LPCB and NYC. Plated, or White Painted (Custom paint to operate in a fire situation or cause TY3504 (5 mm bulb) & TY3505 (3 mm matches and colors other than white it to operate prematurely. bulb): maximum 250 psi (17,3 bar) by are available on request.) Page 1 of 4 JULY, 2004 TFP181 . n Page 2 of 4 TFP181 Physical Characteristics 1/2• NPT • Frame Bronze A Support Cup . Chrome Plated Steel Guide Pins Stainless Steel FRAM Iv ■ R_ Deflector Bronze _ l Compression Screw Brass 1141 �',� CAP Bulb Glass I `�� Cap Bronze or Copper SUPPORT t Sealing Assembly CUP WITH imil, BULB Beryllium Nickel w/Teflon" ROLL FORMED ) THREADS Cover Plate Brass ) � C Retainer Brass \ COMPRESSION • Ejection Spring .... Stainless Steel ` SCREW 1 I' GUIDE ' r Patents PINS (2) �� � = ', U.S.A. 4,014,388 I I I DEFLECTOR Operation •— —_ —_— —.' / POSITION) (DROPPED D EFLECTOR ,. „ L /' G- i - When exposed to heat from a fire, the I SPRINKLER/SUPPORT CUP Cover Plate, which is normally sol- I ASSEMBLY dered to the Retainer at three points, falls away to expose the Sprinkler As- THREAD INTO I RETAINER SUPPORT CUP (j I WITH THREAD - sembly. At this point the Deflector sup- UNTIL MOUNTING �` O O I DIMPLES ported by the Guide Pins drops down SURFACE IS to its operational position. FLUSH WITH EJECTION The glass Bulb contains a fluid that CEILING SPRING expands when exposed to heat. When the rated temperature is reached, the , fluid expands sufficiently to shatter then glass Bulb, activating the sprinkler and allowing water to flow. SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY Design FIGURE 1 Criteria SERIES RFII CONCEALED SPRINKLER ASSEMBLY The RFII (TY3551 & TY3504), 5 mm Bulb Type, Concealed Pendent Sprin- Step 1. The sprinkler must only be klers are UL and C -UL Listed as stand- Installation installed in the pendent position and and response - standard spray sprin- with the centerline of the sprinkler per - klers for use in accordance with the The Series RFII must be installed in pendicular to the mounting surface. current NFPA standard. They are FM accordance with the following instruc- Step 2. Remove the Protective Cap. Approved as standard response - tions: standard spray sprinklers for use in Step 3. With pipe thread sealant ap- accordance with the current FM Loss NOTES plied to the pipe threads, hand tighten Prevention Data Sheets. Do not install any bulb type sprinkler if the sprinkler into the sprinkler fitting. The RFII (TY3531 & TY3505) 3 mm the bulb is cracked or there is a loss of Step 4. Wrench tighten the sprinkler Bulb Ty Concealed Pendent liquid from the bulb. With the sprinkler using only the RFII Sprinkler Wrench B e b p pe, and algid Pendent t Sprin- quick held horizontally, a small air bubble (Ref. Figure 3). The RFII Sprinkler respo n se -sa spray spri Listed should be present. The diameter of the Wrench is to be applied to the Sprin- re r us in s rdane with the current air bubble is approximately 1/16 inch kier as shown in Figure 3. for u standard. They (1,6 mm) for the 155°F/68°C ad 3/32 y h t cu A p inch (2,4 mm) for the 200°F/93°C tern- Step 5. Replace the Protective Cap proved as standard response - stand- perature ratings. (Ref. Figure 4) by pushing it upwards and spray sprinklers for use in accord- leak tight 1/2 inch NPT s sprinkler joint until it bottoms out against the Support A l ance with the current FM Loss sh be obtained with a torque of 7 Cup. The Protective Cap helps prevent Prevention Data Sheets. q damage to the Deflector and Arms dur- The Series RFII Concealed Pendent to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- ing ceiling installation and /or during T ri Seri s are onl listed and a mum of 21 ft.lbs. (28,5 Nm) of torque application of the finish coating of the p y p is to be used to install sprinklers. ceilin It ma also be used to locate proved with the Series RFII Concealed Higher levels of torque may distort the g' y the center the clearance hole Cover Plates having a metallic or white sprinkler inlet with consequent leak- y pushing up painted finish. gently pusg the ceiling material up age or impairment of the sprinkler. against the center point of the Protec- The Series RFII must not be used in Do not attempt to compensate for in Live Cap. applications where the air pressure sufficient adjustment in the Sprinkler above the ceiling is greater than that Assembly by under- or over - tightening NOTE below. Down drafts through the Sup the Sprinkler /Support Cup Assembly. As long as the Protective Cap remains port Cup could delay sprinkler opera- Readjust the position of the sprinkler i n place, the system is cons to tion in a fire situation. fitting to suit. be Out of Service ". * Registered Trademark of DuPont TFP181 Page 3 of 4 FACE OF CLEARANCE HOLE F CLEARANCE _ ' \ SPRINKLER - DIAMETER - HOLE FITTING f DIMENSION C ) i Ems SPRINKLER �� SUPPORT CUP \ r ______. iI I1I J ASSEMBLY 1/2° (12,7 mm) 1 I.I THREADED D ADJUSTMENT kci FACE OF CEILING, ) o / RETAINING RING _ FIGURE 4 MOUNTING DISPOSABLE PROTECTIVE CAP SURFACE j �I 11 I I Step 6. After the ceiling has been com- pleted with the 2 -1/2 inch (63,5 mm) �� _ I I diameter clearance hole and in prepa- ration for installing the Cover Plate As- ' I sembly, remove and discard the Pro - tective Cap, and verify that the 3/16° to 11/16° MANUFACTURER DEFLECTOR COVER PLATE Deflector moves up and down freely. If (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER the Sprinkler has been damaged and REFERENCE 3/32" (2,4 mm) POSITION ASSEMBLY the Deflector does not move up and down freely, replace the entire Sprin- COVER PLATE COVER PLATE kler assembly. Do not attempt to mod- - PROFILE DEPTH DIAMETER ify or repair a damaged sprinkler. DIMENSION B DIMENSION A Step 7. When installing an Air and Dust Seal, refer to Figure 5, otherwise proceed to Step 8. To attach the Air and A: 3-1/4° (82,6 mm) C: 2 -3/8" to 2 -5/8° (60,3 to 66,7 mm) Dust Seal, verify the angle of the out - B: 3/16° (4,8 mm) D: 1 -3/4° to 2 -1/4° (44,5 to 57,2 mm) side edge of the seal is oriented ac- cording to Figure 5. Start the edge of FIGURE the Retainer in the grooved slot of the SERIES RFII CONCEALED SPRINKLER Air and Dust Seal and continue around INSTALLATION DIMENSIONS Dust Seal retainer until the entire Air and Dust Seal is engaged. NOTE The Air and Dust Seal is only to be installed on the periphery of the Re- «i, FRAME .---- _i. tainer. ARM % %` Step 8. Screw on the Cover Plate /Re- tainer Assembly until the Retainer - Figure 2 (or Air and Dust Seal - Figure 0 5) contacts with the ceiling. Do not SUPPORT � 1[ I - I � continue to screw on the Cover CUP Plate /Retainer Assembly such that it "W 04, lifts a ceiling panel out of its normal 11111 „�.,��� A position. If the Cover Plate /Retainer � i Assembly cannot be engaged with the - — --__-- Support Cup or the Cover Plate /Re- 7/8° (23 mm) tainer Assembly cannot be engaged SQUARE sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. ALIGN J iir ARROWS WITH \ \ Care and FRAME ARMS IMMI a l Maintenance ACCEPTS , te The Series RFII must be maintained 0 1/2° SOCKET � -r and serviced in accordance with the DRIVE following instructions: NOTES FIGURE 3 Absence of the Cover Plate Assembly RFII SPRINKLER WRENCH may delay sprinkler operation in a fire situation. Page 4 of 4 TFP181 When properly installed, there is a SUPPORT SPRINKLER FACE OF ORIENT • nominal 3/32 inch (2,4 mm) air gap CUP CEILING SEAL between the lip of the Cover Plate and • SHOWN the ceiling, as shown in Figure 2. This r j = �` r ii COVER ., j� BEVEL AS , air gap is necessary for proper opera- ;. PLATE tion of the sprinkler. If the ceiling is to ` + ) RETAINER —:, be repainted after the installation of ? 111 ' — ,t) ASSEMBLY 6m the Sprinkler, care must be exercised -- to ensure that the new paint does NOT AN seal off any of the air gap. `� RAN 4 10 CLEAN Factory painted Cover Plates MUST � ��� ROOM NOT be epainted. They should be re - — -= LIP OF COVER SEAL placed, if necessary, by factory RETAINER PLATE painted units. FIGURE 5 Do not pull the Cover Plate relative to OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TY3551 & TY3504) the Enclosure. Separation may result. Before closing a fire protection system Inspection Service in accordance with DAMAGES, AND IN NO EVENT main control valve for maintenance local requirements and /or national SHALL TYCO FIRE PRODUCTS' LI- work on the fire protection system that codes. ABILITY EXCEED AN AMOUNT • it controls, permission to shut down the EQUAL TO THE SALES PRICE. affected fire protection system must be L 111fl111ted THE FOREGOING WARRANTY IS obtained from the proper authorities MADE IN LIEU OF ANY AND ALI, and all personnel who may be OTHER WARRANTIES EXPRESS OR by this action must be notified. arranty IMPLIED. INCLUDING WARRANTIES Sprinklers that are found to be leaking OF MERCHANTABILITY AND FIT - or exhibiting visible signs of corrosion Products manufactured by Tyco Fire NESS FOR A PARTICULAR PUR- must be replaced. Products are warranted solely to the POSE. Automatic sprinklers must never be original Buyer for ten (10) years Autom r utom otherwise against defects in material and work - altered painted, plated, ted, sprinklers s or o ot the fo bMode manship when paid for and properly Ordering ed sprfter leaving ving d . Modi- installed and maintained under normal Sprinkler kler must be rey have been exposed replaced. use and service. This warranty will ex- Procedure pire ten (10) years from date of ship - corrosive products of combustion, but have not operated, should be replaced ment by Tyco Fire Products. No war- When placing an order, indicate the full ranty is given for products or product name. Contact your local dis- if they cannot be completely cleaned P Y components manufactured by comps- by wiping the sprinkler with a cloth or tributor for availability. by brushing it with a soft bristle brush. Hies not affiliated by ownership with Sprinkler Assembly: Tyco Fire Products or for products and Specify: (SIN), (specify temperature Care must be exercised to avoid dam- components which have been subject led Pen - on RFII , Concealed Series age to the sprinklers - before, during, to misuse, improper installation, corro- dent rating) Sprinkler STs P/N ( specify). and after installation. Sprinklers dam- sion, or which have not been installed, aged by dropping, striking, wrench maintained, modified or repaired in ac- or the like, must be re- 155F/68C 2 790 -1- twist/slippage, cordance with applicable Standards of TY3551 51 -790 -1 -155 51- 790 -1 -200 placed. Also, replace any sprinkler that the National Fire Protection Associa- TY3504 51 -796 -1 -155 51 -796 -1 -200 has a cracked bulb or that has lost tion, and /or the standards of any other TY3s31 51- 792 -1 -155 51- 792 -1 -200 liquid from its bulb. (Ref. Installation Authorities Having Jurisdiction. Mate- TY3505 51- 797 -1 -155 51 -797 -1 -200 Section). rials found by Tyco Fire Products to be If a sprinkler must be removed, do not defective shall be either repaired or Separately Ordered Cover Plate: reinstall it or a replacement without replaced, at Tyco Fire Products' sole Specify: (specify temperature rating) reinstalling the Cover Plate Assembly. option. Tyco Fire Products neither as- Series RFII Concealed Cover Plate If a Cover Plate Assembly becomes sumes, nor authorizes any person to with (specify finish), P/N (specify). dislodged during service, replace it im- assume for it, any other obligation in mediately. connection with the sale of products or 135F/57C(a) 16 79 24C 1 65 parts of products. Tyco Fire Products Brass 56- 792 -1- 135 56- 792 -1 -165 P P Y Bright Brass 56- 792 -2- 135 56- 792 -2 -165 The owner is responsible for the in- shall not be responsible for sprinkler Chrome 56- 792 -9 -135 56- 792 -9-165 spection, testing, and maintenance of system design errors or inaccurate or Brushed Chrome 5 5- - rotection S stem and de- incomplete information supplied by White 56 792 792 8-165 - their fire P Y P PP Y White (RAL9010)• 56-792-3-135 56- 792 -3-165 vices in compliance with this docu- Buyer or Buyer's representatives. Bright White 56- 792 -4- 135 56- 792 -4-165 ment, as well as with the applicable IN NO EVENT SHALL TYCO FIRE Off Wh ite 56 -792-5-135 56-792-5-165 standards of the National Fire Protec- PRODUCTS BE LIABLE, IN CON- Black 56- 792 -6- 135 56- 792 -6-165 tion Association (e.g., NFPA 25), in TRACT, TORT, STRICT LIABILITY OR Custom m 56 792 -X-135 56-792-X-165 addition to the standards of any other UNDER ANY OTHER LEGAL THE (a) For use with 155E /93C sprinklers. jurisdiction. The in- • For use with 200F/93C sales s on ly . ers. authorities having 1 ORY, FOR INCIDENTAL, INDIRECT, • Eastern Hemisphere sales only. stalling contractor or sprinkler manu- SPECIAL OR CONSEQUENTIAL facturer should be contacted relative to DAMAGES, INCLUDING BUT NOT Sprinkler Wrench: any questions. LIMITED TO LABOR CHARGES, RE- Specify: RFII Sprinkler Wrench, It is recommended that automatic GARDLESS OF WHETHER TYCO P/N 56- 000 -1 -075. sprinkler systems be inspected, FIRE PRODUCTS WAS INFORMED Air and Dust Seal: tested, and maintained by a qualified ABOUT THE POSSIBILITY OF SUCH Specify: Air and Dust Seal, P/N 56- 908 -1 -001. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 . . tqca Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series TY -FRB — Z8, 4.2, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage mospheres. Although corrosion resis- General tant coated sprinklers have passed the standard corrosion tests of the appli - 4 - Description cable approval agencies, the testing is s not representative of all possible cor- • _ - ,# • The Series TY-FRB, 2.8, 4.2, 5.6, and rosive atmospheres. Consequently, it 8.0 K- factor, Upright and Pendent is recommended that the end user be r i Sprinklers described in this data sheet consulted with respect to the suitability I ilia are quick response - standard cover- of these coatings for any given corro- 1 age, decorative 3 mm glass bulb type sive environment. The effects of ambi- :., spray sprinklers designed for use in ent temperature, concentration of light or ordinary hazard, commercial chemicals, and gas /chemical velocity, _ -- occupancies such as banks, hotels, should be considered, as a minimum, shopping malls, etc. along with the corrosive nature of the The recessed version of the Series chemical to which the sprinklers will be TY-FRB Pendent Sprinkler, where ap- exposed. /■• plicable, is intended for use in areas An intermediate level versions of the _\ with a finished ceiling. It uses either a Series TY-FRB Pendent Sprinklers are two -piece Style 10 (1/2 inch NPT) or detailed in Technical Data Sheet , ' `+' Style 40 (3/4 inch NPT) Recessed Es- TFP356, and Sprinkler Guards are de- ( /,r"N cutcheon with 1/2 inch (12,7 mm) of tailed in Technical Data Sheet TFP780 recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the WARNINGS f 4., 3 flush pendent position, or a two-piece The Series TY -FRB Sprinklers de- Style 20 (1/2 inch NPT) or Style 30 (3/4 scribed herein must be installed and ' inch NPT) Recessed Escutcheon with maintained in compliance with this �' ^� 1/4 inch (6,4 mm) of recessed adjust- document, as well as with the applica- ment or up to 1/2 inch (12,7 mm) of ble standards of the National Fire Pro - TY3231 - Pendent 5.6K, 1/2"NPT total adjustment from the flush pen- tection Association, in addition to the TY4131 - Upright 8.0K, 3/4 "NPT dent position. The adjustment provided standards of any other authorities hay- TY4231 - Pendent 8.0K, 3/4 "NPT by the Recessed Escutcheon reduces ing jurisdiction. Failure to do so may the accuracy to which the fixed pipe impair the performance of these de- drops to the sprinklers must be cut. vices. Technical Corrosion resistant coatings, where The owner is responsible for maintain- Data applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. that which would otherwise be ob- The installing contractor or sprinkler Approvals tained when exposed to corrosive at- manufacturer should be contacted UL and C -UL Listed. with any questions. FM, LPCB, and NYC Approved. (Refer to Table A for complete approval IMPORTANT information including corrosion resis- Always refer to Technical Data tant status.) Sheet TFP700 for the "INSTALLER Model /Sprinkler Maximum Working Pressure WARNING" that provides cautions 175 psi (12,1 bar) with respect to handling and instal- identification lation of sprinkler systems and corn- Discharge Coefficient ponents. Improper handling and in- Numbers K = 2.8 GPM /psi (40,3 LPM/barlI stallation can permanently damage K = 4.2 GPM /psi (60,5 LPM/barli a sprinkler system or its compo- TY1131 - Upright 2.8K,1/2 "NPT K = 5.6 GPM /psi / (80,6 LPM/bar nents and cause the sprinkler to fail TY1231 - Pendent 2.8K,1/2 "NPT K = 8.0 GPM /psi (115,2 LPM /barlI to operate in a fire situation or cause TY2131 - Upright 4.2K, 1/2"NPT Temperature Ratings it to operate prematurely. TY2231 - Pendent 4.2K,1/2 "NPT Refer to Table A and B TY3131 - Upright 5.6K,1/2 "NPT Page 1 of 8 JULY, 2004 TFP171 Page 2 of 8 TFP171 ESCUTCHEON 7/16° (11,1 mm) STYLE 10 or 20 ' PLATE SEATING * * NOMINAL RECESSED SURFACE 1/2" MAKE -IN ESCUTCHEON SSU NPT __ DEFLECTOR —= 6 run- ° Pf B'n iii .0 • �= !� 5 1■ � = 1 7/ 16 ° 2-1/4° mm) ( 11,1 mm) I (57,2 4 — �`� NOMINAL I I 2 1 1 MAKE -IN (39,7 mm) I 4I' WRENCH _ _� 2 -3/16 n 3 (55,6 ) A 1 11 FLATS ,_-----_ �i\ 1 SSP DEFLECTOR * --"— 2 -7/8° (73,0 mm) DIA. I 1/2° NPT ** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16° (11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED SURFACE 1/2° MAKE -IN ESCUTCHEON SSU NPT DEFLECTOR 5 — 111111- r •? 2- 3 /16" �� r ( 11,1 1 mm) (55,6 mm) A= A �� � M A NOMINAL 4 KE -IN w 1 -1/2° I 1I rpi I clIM� 1 (55 6 mm) ' � ! 2 (38,1 WRENCH 3 1 II -- 111 - F LATS SSP DEFLECTOR — 2 -7/8" (73,0 mm) DIA. —I 1/2" NPT ** I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K- FACTOR, 1/2 INCH NPT Y m E Finishes Bulb Glass v Sprinkler: Refer to Table A and B Compression Screw Bronze Operation `` Recessed Escutcheon: White Coated, Deflector .... .. Copper /Bronze Chrome Plated, or Brass Plated Bushing (K =2.8) Bronze The glass Bulb contains a fluid which 2 expands when exposed to heat. When y Physical Characteristics the rated temperature is reached, the 'm Y f expands sufficiently to shatter the cc Frame Bronze glass Bulb, allowing the sprinkler to E Button Brass /Copper activate and water to flow. Sealing Assembly o Beryllium Nickel w/Tefiont 1- TFP171 Page 3 of 8 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 or 20 PLATE SEATING ** NOMINAL RECESSED SURFACE f1 /2 MAKE -IN ESCUTCHEON DEFLECTOR r � 7/16" ter 5 (55,6 mm) I 2 -3/16" ---- 1s' " I (11,1 mmNOMINA) ; I IFT i t A F �/ � L 4 I MAKE - IN i 2-3/16" rf ti - 4 (38,1 / mm) I HMO (55 6 mm) ' 2 WRENCH 1 . FLATS _= I 3 L 1 SSP DEFLECTOR * — 2 -7/8" (73,0 mm) DIA. 1/2° NPT I PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION . 1 3 - Sealing 4 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw * * Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K- FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2° (12,7 mm) STYLE 30 or 40 PLATE SEATING * NOMINAL RECESSED SSU* SURFACE NPT ESCUTCHEON DEFLECTOR rr i fs 7T' 11.101T`� 6* 1/2° I " 5 2- 5/16 °�� ( 12,7 mm) (58,7 mm) ��� -IIMrrrir I NOMINAL li 4 1 MAKE -IN 1 9/1 6°) I ,� 2,2 -1/4" mm) 0 � y 2 (39,7 C (57,2 , 7,c I • . S = 7 3 %1 v` 1 SSP DEFLECTOR * 2 -7/8° (73,0 mm) DIA. 3/4° NPT l PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw ** Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K- FACTOR, 3/4 INCH NPT Listing is based on the requirements of installation Design NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre - Criferia vention Data Sheets ). Only the Style The Series TY-FRB Sprinklers must be 10, 20, 30, or 40 Recessed Escutch- installed in accordance with the follow - The Series TY Pendent and Up- eon, as applicable, is to be used for ing instructions: right Sprinklers are intended for fire recessed pendent installations. protection systems designed in ac- NOTES cordance with the standard installation Do not install any bulb type sprinkler if rules recognized by the applicable the bulb is cracked or there is a loss of Listing or Approval agency (e.g., UL liquid from the bulb. With the sprinkler • Page 4 of 8 TFP171 SPRINKLER FINISH (See Note 7) inch NPT sprinkler joint should be ob- K TYPE TEMP. BULB NATURAL CHROME WHITE'"* tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 UOUID BRASS PLATED POLYESTER ft.lbs. (40,7 Nm) of torque is to be used 135 °F /57 °C Orange to install sprinklers with 3/4 NPT con - g nections. Higher levels of torque may PENDENT 155 °F /68 °C Red distort the sprinkler inlet and cause (TY1231) 1, 2, 3, 5 leakage or impairment of the sprinkler. and 175'F/79°C Yellow Do not attempt to make -up for insuffi- UPRIGHT 200 °F /93 °C Green 131) cient adjustment in the escutcheon 2.8 286 °F /141 °C Blue plate by under- or over - tightening the 1/2° sprinkler. Readjust the position of the NPT 135 °F /57 °C Orange sprinkler fitting to suit. RECESSED 155 °F /68 °C Red PENDENT The Series TY - FRB Pendent and Up (TY1231)* 175 °F /79 °C Yellow right Sprinklers must be installed in Figure 5 200 °F /93 °C Green 1, 2, 5 accordance with the following instruc- tions. 135 °F /57 °C Orange Step 1. Pendent sprinklers are to be RECESSED installed in the pendent position, and PENDENT 155°F/68°C Red upright sprinklers are to be installed in • (TY1231)** 175'F179°C Yellow the upright position. Figure 6 200'F/93°C Green Step 2. With pipe thread sealant ap- 135 °F /57 °C Orange plied to the pipe threads, hand tighten PENDENT the sprinkler into the sprinkler fitting. 155'F/68°C Red (TY2231) Step 3. Tighten the sprinkler into the and 175'F179°C Yellow sprinkler fitting using only the W -Type UPRIGHT 200 °F /93 °C Green 6 Sprinkler Wrench (Ref. Figure 13). 2131 With reference to Figures 1, 2, 3, and 4.2 (TY2131) 286 °F /141 °C Blue 2 4, the W -Type 6 Sprinkler Wrench is to 1/2" be applied to the sprinkler wrench NPT 135 °F /57 °C Orange flats. RECESSED 155'F/68°C Red PENDENT (TY2231)* 175 °F /79 °C Yellow The Series TY - FRB Recessed Pen - Figure 7 200 °F /s3 °C Green dent Sprinklers must be installed in accordance with the following instruc- 135'F/57°C Orange tions. RECESSED 155'F/68°C Red Step A. After installing the Style 10. PENDENT 20, 30, or 40 Mounting Plate, as appli- (TY2231)** 175'Ff79°C Yellow cable, over the sprinkler threads and Figure 8 200 °F /93 °C Green with pipe thread sealant applied to the - pipe threads, hand tighten the sprin- NOTES: kler into the sprinkler fitting. 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Step B. Tighten the sprinkler into the 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response sprinkler fitting using only the W -Type Sprinklers. 7 Recessed Sprinkler Wrench (Ref. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin Figure 14). With reference to Figure 1, klers. 5. Approved by the City of New York under MEA 354 -01 -E. 2, 3, and 4, the W - Type 7 Recessed 7. Where Polyester Coated Sprinklers are noted to be UL and C -UL Listed, the sprin- Sprinkler Wrench is to be applied to klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. the sprinkler wrench flats. ' Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Step C. After the ceiling has been in- Recessed Escutcheon, as applicable. stalled or the finish coat has been ap- ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment plied, slide on the Style 10, 20, 30, or Recessed Escutcheon, as applicable. 40 Closure over the Series TY FRB *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available Sprinkler and push the Closure over the Mounting Plate until its flange TABLE A comes in contact with the ceiling. LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K- FACTOR SPRINKLERS held horizontally, a small air bubble A leak tight 1/2 inch NPT sprinklerjoint should be present. The diameter of the should be obtained with a torque of 7 air bubble is approximately 1/16 inch to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi - (1,6 mm) for the 135 °F /57 °C to 3/32 mum of 21 ft. lbs. (28,5 Nm) of torque inch (2,4 mm) for the 286 °F /141 °C may be used to install sprinklers with - - -- - temperature ratings. 1/2 NPT connections. A leak tight 3/4 • • • TFP171 Page 5 of 8 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB NATURAL CHROME WHITE*** LEAD LIQUID BRASS PLATED POLYESTER COATED 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red 1,2,3,4,5,6,7 1,2,3,5 and 175 °F /79 °C Yellow UPRIGHT 200 °F /93 °C Green 5.6 (TY3131) 286 °F /141 °C Blue 1/2° NPT 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 4, 5 N/A (TY3231p 175 °F /79 °C Yellow Figure 9 200 °F /93 °C Green 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1,2,3,4,5 1,2,4,5 N/A (TY3231)** 175 °F /79 °C Yellow Figure 10 200 °F /93 °C Green 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY4231) 1, 2, 5 and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7 UPRIGHT 200 °F /93 °C Green 8.0 (TY4131) 286 °F /141 °C Blue 3/4" NPT 135 °F /57 °C Green RECESSED 155 °F /68 °C Orange PENDENT 1, 2, 4, 5 N/A (TY4231)* 175 °F /79 °C Red Figure 11 200 °F /93 °C Yellow 135 °F /57 °C Orange RECESSED 155 °F /68 °C Red PENDENT 1, 2, 3, 4, 5 N/A (TY4231)** 175 °F /79 °C Yellow Figure 12 200 °F /93 °C Green NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31- 53- 428- 4444/Fax 31- 53- 428 - 3377). 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2° NPT) or Style 40 (3/4° NPT) 3/4° Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4° NPT) 1/2° Total Adjustment Recessed Escutcheon, as applicable. * ** Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K- FACTOR SPRINKLERS Page 6 of 8 TFP171 2 -7/8° DIA. _ 2 -7/8° DIA. 5/8±1/4° (73,0 mm) 3/4° (19,1 mm) 1/2±1/8" (73,0 mm) 1/2° (12,7 mm) (15,9±6,4 mm) 2 -1/4" DIA. 1/4° (6,4 mm) (12,7±3,2 mm) 2 -1/4' DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8° 1/8" J Il • �i (3 mm) ° (3,2 mm) I ! , %__ _j II N. I SURFACE IN MOUNTING � . . SURFACE iir• ..... �ir•tiN CLOSURE SERIES 1 -5/16' (33,3 mm) CLOSURE SERIES 1 -5/16° (33,3 mm) TY -FRB 13/16° (20,6 mm) TY -FRB 1 -1/16" (27,0 mm) FIGURE 5 FIGURE 6 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT ' STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K- FACTOR, 1/2 INCH NPT 2.8 K- FACTOR, 1/2 INCH NPT 2 -7/8° DIA. _ 2 -7/8° DIA. 5/8 ±1/4" (73,0 mm) 3/4' (19,1 mm) 1/2±1/8° (73,0 mm) 1/2' (12,7 mm) (15,9±6,4 mm) 2 -1/4' DIA. 1/4° (6,4 mm) (12,7±3,2 mm) 2 -1/4° DIA. 1/4° (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8° 1/8° Mil (3,2 mm) 0. Or // (3,2 mm) NW . - _ � } \ II, . f MOUNTING II, �r ' MOUNTING ,I SURFACE � . SURFACE - - - - CLOSURE SERIES 1 -1/4' (31,8 mm) CLOSURE SERIES 1 -1/4° (31,8 mm) TY-FRB 3/4° (19,1 mm) TY -FRB 1° (25,4 mm) FIGURE 7 FIGURE 8 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K- FACTOR, 1/2 INCH NPT 4.2 K- FACTOR, 1/2 INCH NPT used to cover a clearance hole, may and after installation. Sprinklers dam - Care and delay the time to sprinkler operation in aged by dropping, striking, wrench a fire situation. twist/slippage, or the like, must be re- Maintenance Sprinklers that are found to be leaking has a crackedpbulb or that has lost The Series TY-FRB Sprinklers must be or exhibiting visible signs of corrosion liquid from its bulb. (Ref. Installation maintained and serviced in accord- must be replaced. Section). ance with the following instructions: Automatic sprinklers must never be Frequent visual inspections are rec- painted, plated, coated or otherwise ommended to be initially performed for NOTES altered after leaving the factory. Modi- corrosion resistant coated sprinklers, Before closing a fire protection system fied sprinklers must be replaced. after the installation has been corn- main control valve for maintenance Sprinklers that have been exposed to work on the fire protection system that corrosive products of combustion, but pleted, to verify the integrity of the cor- it controls, permission to shut down the have not operated, should be replaced annual resistant oo tions s per r, NAPA A 25 affected fire protection system must be if they cannot be completely cleaned s pec obtained from the proper authorities by wiping the sprinkler with a cloth or should suffice; however, instead of in- and all personnel who maybe affected by brushing it with a soft bristle brush. specting from the floor level, a random by this action must be notified. sampling of close -up visual inspec- Care must be exercised to avoid dam- tions should be made, so as to better Absence of an escutcheon, which is age to the sprinklers - before, during, determine the exact sprinkler condi- TFP171 Page 7 of 8 2 -7/8° DIA. 2 -7/8" DIA. _ 5/8±1/4" (73,0 mm) 3/4' (19,1 mm) 1/2±1/8° (73,0 mm) 1/2° (12,7 mm) (15,9±6,4 mm) 2 -1/4° DIA. 1/4'(6,4 mm) (12,7±3,2 mm) 2 -1/4° DIA. 1/4° (6.4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8° 1/8" �� (3,2 mm) '� (3,2 m m) � G:lfitll, ' (3 ] _04 II Tilfir I ii■ ■Ame■ .3 M I I, ■, f MOUNTING II, ' MOUNTING , SURFACE SURFACE CLOSURE SERIES 1 -1/4° (31,8 mm) CLOSURE SERIES 1 -1/4° (31,8 mm) TY-FRB 3/4" (19,1 mm) TY -FRB 1° (25,4 mm) FIGURE 9 FIGURE 10 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT ' STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT 5.6 K- FACTOR, 1/2 INCH NPT 2 -7/8° DIA. 2 -7/8" DIA. - 5/8 ±1/4° (73,0 mm) 3/4' (19,1 mm) 1/211/8, (73,0 mm) 1/2° (12,7 mm) (15,9±6,4 mm) 2 -1/4° DIA. 1 1/4' (6,4 mm) (12,7±3,2 mm) 2 -1/4° DIA. 1/4° (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8° I 1/8° ' (3,2 mm) ' (3,2 mm) mi---,—_—_ ■�I i ■)I . ,7. Al ', MOUNTING IIP MOUNTING � SURFACE SURFACE 1 • CLOSURE SERIES 1 -5/16° (33,3 mm) CLOSURE SERIES 1 -5/16° (33,3 mm) TY-FRB 13/16° (20,8 mm) TY-FRB 1 -1/16" (27,0 mm) FIGURE 11 FIGURE 12 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT 8.0 K- FACTOR, 3/4 INCH NPT tion and the long term integrity of the corrosion resistant coating, as it may ! WRENCH be affected by the corrosive conditions �►' RECESS present. , WRENCH RECESS fo The owner is responsible for the in- (END °A° USED FOR l spection, testing, and maintenance of 1/2" NPT MODELS) their fire protection system and de- �" vices in compliance with this docu- f ment, as well as with the applicable ...' standards of the National Fire Protec- WRENCH RECESS PUSH WRENCH tion Association (e.g., NFPA 25), in (END "B" USED FOR IN TO ENSURE addition to the standards of any other 3/4° NPT MODELS ENGAGEMENT authorities having jurisdiction. The in- WITH SPRINKLER stalling contractor or sprinkler manu- FIGURE 13 WRENCHING AREA facturer should be contacted relative to W -TYPE 6 SPRINKLER any questions. WRENCH It is recommended that automatic FIGURE 14 sprinkler systems be ins local requirements and /or national W -TYPE RECESSED tested, and maintained by a qualified codes. SPRINKLER WRENCH Inspection Service in accordance with Page 8 of 8 TFP171 P/N 57 - XXX - X - XXX I I TEMPERATURE MODEUSIN RATING SPRINKLER 330 2.8K UPRIGHT (1 /2 "NPT) TY1131 135 135 °F /57 °C 331 2.8K PENDENT (1 /2 "NPT) TY1231 1 NATURAL BRASS 155 155 °F /68 °C 340 4.2K UPRIGHT (1 /2 "NPT) TY2131 4 WHITE POLYESTER 175 175 °F /79 °C 341 4.2K PENDENT (1 /2 "NPT) TY2231 3 WHITE (RAL9010)' 200 200 °F /93 °C 370 5.6K UPRIGHT (1 /2 "NPT) TY3131 9 CHROME PLATED 286 286 °F /141 °C 371 5.6K PENDENT (1 /2 "NPT) TY3231 7 LEAD COATED 390 8.0K UPRIGHT (3/4 "NPT) TY4131 391 8.0K PENDENT (3/4 "NPT) TY4231 • Eastern Hemisphere sales only. TABLE C PART NUMBER SELECTION ' SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS ORY, FOR INCIDENTAL, INDIRECT, Recessed Escutcheon: Limited SPECIAL OR CONSEQUENTIAL Specify: Style (specify) Recessed Es- DAMAGES, INCLUDING BUT NOT cutcheon with (specify finish), P/N Warranty LIMITED TO LABOR CHARGES, RE- (specify). GARDLESS OF WHETHER TYCO Products manufactured by Tyco Fire FIRE PRODUCTS WAS INFORMED 1/2' (15 mm) Products are warranted solely to the ABOUT THE POSSIBILITY OF SUCH Style 10 original Buyer for ten (10) years DAMAGES, AND IN NO EVENT Chrome Plated P/N 56- 701 -9-010 against defects in material and work- SHALL TYCO FIRE PRODUCTS' LI- White Coated P/N 56 -701 -4-010 manship when paid for and properly ABILITY EXCEED AN AMOUNT Whits Plated 0' P/N 56-701-3-010 installed and maintained under normal EQUAL TO THE SALES PRICE. Brass Plated P/N 56- 701 -2 -010 use and service. This warranty will ex- T FOREGOING WARRANTY IS 1/2° (15 mm) pire ten (10) years from date of ship- Style 20 ment by Tyco Fire Products. No war- MADE IN LIEU OF ANY AND ALL Chrome Plated P/N 56 -705 -9 -010 ranty is given for products or OTHER WARRANTIES EXPRESS OR White Coated P/N 56 -705 -4 -010 components manufactured by compa- IMPLIED. INCLUDING WARRANTIES White RAL9010' P/N 56- 705 -3-010 Hies not affiliated by ownership with OF MERCHANTABILITY AND FIT- Brass Plated P/N 56 -705 -2 -010 Tyco Fire Products or for products and NESS FOR A PARTICULAR PUR- 3/4° (20 mm) components which have been subject POSE, Style 30 to misuse, improper installation, corro- Chrome Plated P/N 56- 705 -9-011 sion, or which have not been installed, White Coated P/N 56 -705 -4 -011 maintained, modified or repaired in ac- White Plated 0' P/N 56- 705 -3-011 cordance with applicable Standards of ac- Ordering Brass Plated P/N 56-705-2-011 the National Fire Protection Associa- Procedure 3/4' (20 mm) tion, and /or the standards of any other Style 40 Authorities Having Jurisdiction. Mate- 0matt>pratgger Fecal distributor for avail- Chrome Plated P/N 56- 700 -9-010 rials found by Tyco Fire Products to be abaft indicate the White Coated P/N 56- 700 -4-010 defective shall be either repaired or full'product White RAL9010' P/N 56 -700 -3 -010 replaced, at Tyco Fire Products' sole name. Refer to Brass Plated P/N 56 -700 -2 -010 option. Tyco Fire Products neither as- the Price List for o P Y complete listing 'Eastem Hemisphere sales only. sumes, nor authorizes any person to of Part Numbers. assume for it, any other obligation in Sprinkler Wrench: connection with the sale of products or Sprinkler Assemblies with NPT Specify: W -Type 6 Sprinkler Wrench, parts of products. Tyco Fire Products Thread Connections: P/N 56- 000 -6 -387. shall not be responsible for sprinkler Specify: (Specify Model /SIN), Quick system design errors or inaccurate or Response, (specify K- factor), (specify Specify: W -Type 7 Sprinkler Wrench, incomplete information supplied by temperature rating), Series TY-FRB P/N 56- 850 -4 -001. Buyer or Buyer's representatives. (specify Pendent or Upright) Sprinkler IN NO EVENT SHALL TYCO FIRE with (specify type of finish or coating), PRODUCTS BE LIABLE, IN CON- P/N (specify from Table C). TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE - TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446