Loading...
Permit Ii v CITY OF TIGARD BUILDING PERMIT PERMIT #: BUP2007 -00063 "COMMUNITY DEVELOPMENT DATE ISSUED: 4/16/2007 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 1S12600-00300 SITE ADDRESS: 09510 SW WASHINGTON SQUARE RD H - ZONING: C - G SUBDIVISION: WASHINGTON SQUARE LOT: JURISDICTION: TIG PROJECT: TRADE SECRET Project Description: TI REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ALT FIRST: 1,399 sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 2N sf N: S: E: W: OCCUPANCY GRP: M TOTAL AREA: 1,399 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: 63 BASEMENT: sf AREA SEP. RATED: STOR: 1 HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET:N DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : U HNDICP ACC:Y BEDRMS: BATHS: IMP SURFACE: PRO CORR: N PARKING: VALUE: $ 60,000.00 Owner: Contractor: WASHINGTON SQUARE LLC ARCHITECTURAL INTERIORS & CONST BY THE MACERICH COMPANY PO BOX 73397 9585 SW WASHINGTON SQUARE RD PUYALLUP, WA 98373 TIGARD, OR 97223 Contact #: PRI 253 - 848 - 5948 Phone: FAX 253 - 848 -0457 Reg #: LIC 115334 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUPPLN] Pin Rv 2/1/2007 $341.58 [FLS] FLS Pln Rv 2/1/2007 $210.20 [BUILD] Permit Fee 4/16/2007 $525.50 [TAX] 8% State Surcha 4/16/2007 $42.04 Total $1,119.32 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By Permittee Signatures / .// , _ _ _ / // ii / Call 503.639.4175 by 7:00 a.m. for an inspection that business d..� This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. r 7 a/' >4'' -S Building Pernik ApplicatioIR C L i 'V O • ' FOR OFFICE USE ONLY 71 J City of Tigard Date B - q �/i � J Permit No' J/ Iy'J — 5 00 6 ° 13125 SW Hall Blvd., Tigard, OR 97 223' ..'J (% l /��� Received Plan Review'M''t'� Phone. 503 639.4171 Fax 503 598 I Y 1 Date /B A A Other Permit T IGARD Inspection Line. 503 639.4175 y �� rI(jAND Date Read ��� See Attached Checklist for g g atdnliNG DIVISION Notified/Meth.. / l0 d ` ' Supplemental www ti and -or. ov dtl V �' pp lemental Information :7/., , , aim TYPE OF WORK REQUIRED DA , : 1- AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ® Addition /alteration /replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ I- and 2- family dwelling ® Commercial /industrial Valuation: $ ❑ Accessory building ❑ Multi- family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 9510 Washington Square Rd New dwelling area: square feet City /State /ZIP: Tigard, OR 97223 Garage /carport area: square feet Suite/bldg. /apt. no.: K01 Project name: TRADE SECRET Covered porch area: square feet Cross street/directions to job site: SW HALL BLVD & GREENBURG RD HWY 217 Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: WASHINGTON SQUARE MALL 1 Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. COMPLETE REMODEL OF THE EXISTING TRADE SECRET HAIR SALON Valuation: $$60,000.00 Existing building area: 1377 square feet New building area: square feet ❑ PROPERTY OWNER ® TENANT Number of stories: 1 Name TRADE SECRET (REGIS CORPORATION) Type of construction: ll -B Address: 7201 METRO BLVD Occupancy groups: City /State /ZIP: MINNEAPOLIS, MN 55439 Existing: B Phone: (952)918.4603 Fax: (952)918.4602 New: ® APPLICANT ® CONTACT PERSON NOTICE Business name: COMMERCIAL PERMITS, INC. All contractors and subcontractors are required to be Contact name: BRIGITTE ARMS licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: 2620 63 STREET jurisdiction in which work is being performed. If the City /State /ZIP: FENNVILLE, MI 49408 applicant is exempt from licensing, the following reasons 2 apply' S A S8 Phone: (269) 561.7284 Fax: : (269) 561.7485 Commercial Permits is an expediti firm E -mail: brigitte @starband.net !S ..c.I ao not a contractor. The contractors will CONTRACTOR pull all permits. Business name: TF$fl A94 t (t, e 1 l.tQ fj'L' 1 EQIOP. 4 &13 BUILDING PERMIT FEES* Address: p Azov /3b9/ (Please refer to fee schedule) (� Structural plan review fee (or deposit) 551.78 City /State /ZIP: PuvA LL up ( 373 � a FLS plan review fee (if applicable): r Phone: (p 3) Dti g - 59 s Fax:0 )4t lit.- 0457 CCB tic. It 6 1,/ Total fees due upon application: $551.78 _( � This permit application received: $551.78 Authorized signature: a . on expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name Brigitte Arms Date. 1/28/07 * Fee methodology set by Tn- County Building Industry Service Board I \ Building \Permits \BUP- PermitApp doc 03/21/06 440- 4613T(I I/02 /COM/WEB) • 4 0, 0 — � 06(03 Form 4a Project Name: Trade Secret (Remodel), Portland, Page: 1 SYSTEMS - GENERAL Applicability Plans /Specs Discussion of qualifying .`Sho c pliance by including a drawing sheet, detail number, exceptions on page 4 -14 ` spec' 'cation section and subparagraph 1. Applicablity (Section 1317) ;, ; Is this form required? y El Form Required. Complete form • a n- i • pis be i nstalled, or components of an existing HVAC system are being replaced (I.e., equipm controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area: Exception I=1-1 I=1 -2 ❑ -3 Area: Exception ❑ -1 I=1 - ❑ -3 Area: Exception El -1 ❑ -2 ❑ -3 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) El No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. ❑ Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: ❑ -4a ❑ -4b ❑ -4c ❑ -4d ❑ -4e ❑ -4f ❑ -4g ❑ -4h C1-41 ❑ -4 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. o Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as reauired by Sections 1317.7 &1317.8. 5. Distribution Transformers (Section 1316.1) No Distribution Transformers. The plans /specs do not call for new distribution transformers. ❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. ❑ Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: O -1 0 -2 0 -3 ❑-4 ❑ -5 0 -6 0 -7 0 -8 0 -9 0 -10 0 -1 0 - 120 -13 0 -14 Attach relevant documentation for appropriate exception. The plans /specs show compliance in the r,b following locations: 4 ;fiL p� 4 -1 Compliance with OSSC, effective 01/01/05 Form 4a Project Name: Trade Secret (Remodel), Portland, OR Page: 2 SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, Exception 0-1 0 Portions of the building that qualify: The plans /specs show compliance in the following locations: MP1 6.2 Off -hour Controls - Auto Setback or Shutdown (Section 1317.4.3) • Complies. Systems must have at least one of the following features: O Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces served. O Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: O Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception 0-1 0 The plans /specs show compliance in the following locations: MP1 6.3 Control Capabilities (Sec. 1317.4.2.1) • Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 0-1 0 Portions of the building that qualify: The plans /specs show compliance in the following locations: MP1 6.4 Optimum Start Controls (Section 1317.4.3.2) O Complies. Separate HVAC systems have controls capable of varying start-up time of system to just meet temperature set point at time of occupancy. ❑ Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: MP1 6.5 Heat Pump Controls (Section 1317.4.4) O No Heat Pump. The plans /specs do not call for a new heat pump ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. The plans /specs show compliance in the following locations: 4�A 4 -2 Compliance with OSSC, effective 01/01/05 Form 4a Project Name: Trade Secret (Remodel), Portland, OR Page: 5 SYSTEMS — GENERAL 13. High Occupancy Ventilation (Section 1317.2.2) ❑ Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: Plans /specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified: ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. 0 No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Large Volume Fan Systems (Section 1318.4.2.4) o Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following locations: 15. Variable Speed Drives (Section 1317.10.3.1) o Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following locations: 16. Service Water Heating (Sec. 1315) ❑ No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. El Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: Portions of the building that qualify: The plans /specs show compliance in the following locations: MP1 r o 4 -5 Compliance with OSSC, effective 01/01/05 Form 4a Project Name: Trade Secret (Remodel), Portland, OR Page: 6 SYSTEMS - GENERAL 17. Swimming Pools, Spas and Hot Tubs (Section 1315.5) El No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 18. Fume Hoods (Section 1317.2.1.) El No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: ❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: 19. Parking Garage Ventilation (Section 1317.2.3) El No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 20. Kitchen Hoods (Section 1317.11) El Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. The plans /specs show compliance in the following locations: � r 21. Outside Heating Systems (Section 1317.12) El No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. ❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4 -6 Compliance with OSSC, effective 01/01/05 • • Worksheet 41- Project Name Trade Secret (Remodel), Portland, OR Page' 7 AIR TRANSPORT ENERGY Complete one worksheet for each fan system > 7.5 horsepower. Fan system horsepower is the sum of motor brake horsepower of all supply, return, and exhaust fans (including series fan - powered terminal units) that operate during design conditions. Fan System ID:I Existing VAV box (VAV -1) to remain. Areas Served:IRegis space ❑ System serves hospital or laboratory and include flow control device for maintaining precise pressure control. Maximum Fan Type (Supply, Nameplate Fan Identifier Return, Exhaust, Series Constant Volume Motor Brake Nameplate Motor HP (Tag) VAV) CFM or VAV HP Motor HP Allowed Exist VAV -1 SVAV 1,975 VAV 1 -Jan 0 33 hp 1 0 The Plans /Specs show brake hp, nameplate hp, and CFM in the following locations: I MP -1 (Existing vav box to remain) Total System - Total - Total System - Supply Fan Constant Volume, VAV, System Max Brake HP Brake HP Nameplate CFM or Hospital /Lab Brake HP Allowed Complies HP Complies 0 VAV 0.3 NA Yes Additional Pressure Drop Credit (all systems). Complete the section below if system contains filtration with a pressure drop at design flow in excess of 1" w.c. ( when filters are clean), heat recovery, or direct evaporative humidifier /cooler. Additional Pressure Drop Credit for Hospitals and Laboratories. Complete the section below if system serves a hospital or laboratory and contains rully ducted return /exhaust, return /exhaust air flow control devices, or individual filter system efficiencies. Additional Pressure Drop Credits Pressure Drop, Inches, W.C. ❑ Filtration Pressure Drop >1" w.c. All Systems ❑ Heat Recovery ❑ Direct Evaporative Humidifier /Cooler Hospital and ❑ Fully Ducted Return /Exhaust (0.5" credit) Laboratory ❑ Return /Exhaust Flow Control Device (0.5" credit) Systems Only ❑ Individual Filter Efficiency > or = 85% (0.5" credit) Total Additional Pressure Drop Credit: ❑ Manufacturer's product data sheet(s) is attached and design values are shown in plans /specs in the following locations I I Adjusted Total Brake Constant Volume or VAV (Use VAV Total Additional Max Allowed HP (from Adjusted Brake Supply CFM for Hospital or Lab Systems) Pressure Drop Brake HP above) HP Complies Add New Worksheet 41 4 -22 1 7 Compliance with OSSC, effective 01/01/05 6 ( p � GV - 7 - 000( Form 5a Project Name: Trade Secret Washington Square, Portland (Tigard), OR Page: 1 of 4 LIGHTING - GENERAL ' 1. Interior Exceptions (Section 1313.1) ❑ No Interior Lighting. The building plans and specifications do not call for new or altered interior lighting Skip to item 5, Exterior building Lighting - General, below Exceptions O Exceptions. 1 The building or part of the building qualifies for an exception from code lighting Discussion of qualifying requirements. Applicable code exception is number: exceptions in instructions section 2. Lighting equipment that qualifies for an exception - in addition to general lighting and is separately controlled. Applicable code exception is number: 1313 4 2.1 Areas of the building and equipment that qualify for any exceptions: Plans /Specs Show compliance by including a Retail Sales Area track lighting allowance of 1.75W /sq ft drawing sheet, detail number, and /or specification section and subparagraph 2. Local Shut -off controls (Section 1313.3.1.1) El Complies. At least one local shut -off lighting control for every 2,000 square feet of lighted floor area and for all spaces enclosed by walls or ceiling height partitions. This control(s) is detailed in the building plans on drawing number: ID Exception. The building or part of the building qualifies for an exception. Applicable code exception is Section 1313.3.1.1, Exception: 4 Portions of the building that qualify: 3. Automatic Shutoff Controls (Section 1313.3.1.2) ❑ Not Applicable. Office floor area is not over 2,000 square feet of contiguous office floor area or permitted space is not over 5,000 square feet. No offices less than 300 square feet, meeting or conference rooms, or school classrooms. 9 Complies. All interior lighting systems are equipped with a separate automatic control to shut off lighting during unoccupied periods. Offices less than 300 square feet, meeting and conference rooms, and school classrooms shall be equipped with occupancy sensors that comply with Section 1313.3.1.2.1. Compliance details in plans /specs: ❑ Exception. The building or part of the building qualifies for an exception. l he applicable code exception is Section 1313.3.1,2, Exception: Portions of the building that qualify: 4. Daylighting Controls (1313.3.1.3) O No classrooms or atriums with skylights or window to wall ratio greater than 50 %. ❑ Complies. All classrooms and atriums with window to wall ratio greater than 50% and /or skylights are equipped with automatic daylight sensing controls, as required by Section 1313.3.1.3.1 and Section 1313.3.1.3.2. The daylight sensors specified comply with Section 1313.3.1.3 3. Compliance details in plans /specs: Exterior Build -ing 5. Exterior Lighting (Section 1313.5) Lighting o Complies. The plans do not call for use of incandescent or mercury vapor lamps for use on building exterior is lighting directed to illuminate ❑ Exception. The building plans indicate luminaires with incandescent or mercury vapor lamps, but are the exterior of the building and specified for use in or around swimming pools, water features, or other locations subject to requirements adjacent walkways and loading of Article 680 of the 2002 National Electrical Code. areas with or without canopies Clock Switches shall be astronomic (seasonal 6. Exterior and Canopy Lighting Controls (Section 1313.3.2) correcting) type with separate 0 Complies. The building plans and specifications include photoelectric and /or clock switches on all exterior programs for each day of the lighting systems which are designed and programmed to extinguish lights when daylight is present, as week and shall store energy to required by Section 1313.3 2 maintain timekeeping dunng power outages 7. Interior Connected Lighting Power (Section 1313.4) YES Complies. The interior lighting power does not exceed the interior power allowance established aa in either the Tenant Space Method (Form 5b) or the Space -by -Space Method (Form 5c). • Tenant Space Method (Form 5b) :Space-by-Space Method (Form 5c) 5 -1 Compliance with OSSC, effective 01/01/05 Form 5c Project Name. Trade Secret Washington Square, Portland (Tigard), OR Page 2 of 4 INTERIOR LIGHTING POWER - Space -by -Space Method Lighting Power 1. Total Interior Lighting Power Budget from Worksheet 5b -1 (Sum of Column (I)) 2,362 Budget 2. Total length of track lighting (ft) 10 Track Lighting Power 3. Line 2 multiplied by 37.5 Watts /ft 375 4. Total amperage of circuit breaker(s) serving track lighting (amps) 5. Voltage of circuit breaker serving track lighting (volts) 6 Maximum wattage of track lighting (multiply line 4 by line 5) 7. Track Lighting Power (lesser value of line 3 or line 6) 375 8. Total Interior Lighting Power from Worksheet 5b -1 (Sum of Column (m)) + 1,958 Building's Lighting 9 Total Adjusted Lighting Power (line 7 + line 8) = 2,333 Power 10. Does design meet budget? Line 9 must be no greater than line 1. YES f W, w-r• 5-3 Compliance with OSSC. effective 01/01/05 I Work Project Name Trade Secret Washington Square, Portland (Tigard), OR Page: 3 of 4 LIGHTING SCHEDULE • (a) (b) (c) (d) (e) (f) Lum Luminaire Is Luminaire ID Luminaire Lamp Ballasts Power From Type Description No. Description No Description (watts) Table 5c 7A1 Compact Fluorescent Quad - 2- CFQ26W /G24q -3- ELECT -52W 2 CFQ26W /G24q -3 2 Electronic 52 YES 7A2 Compact Fluorescent Quad - 2- CFQ26W /G24q -3- ELECT -52W - 2 CFQ26W /G24q -3 2 Electronic 52 YES 7B1 Track Lighting _ Track Lighting - - -- -- -- 37.5 YES 7B2 Track Lighting , •1 Track Lighting -- -- -- 37.5 YES 7C1 User Defined -4-60W G -LAMP STRIP - 4 40W G -LAMP 160 NO 7C2 User Defined 11 Par NFL - 1 50W Par — 50 NO _.i. w -i, - _ ...._...._ -_ __ - - - d.� -I . .._,_.. _,.......__ _.. - _._.......__.......... -_... .._ - _ _ _..... � ._._..........,,..,......W . ,�.. w...m -,�_,rt J - -r ----A- _ Lighting Forms -v2 1.xls Worksheet 5b-1 Project Name: Trade Secret Washington Square, Portland (Tigard), OR Page 4 of 4 INTERIOR LIGHTING POWER Space -by -Space Method Only Skip to column (f) rf using the Tenant Space Method (a) (b) (c) (d) (e) Lure ( ID (9) (h) (t) 0) (k) from Quantity of Room ID (do Space Type Space Lighting Power Worksheet Luminaires (or Luminaire Lighting Room not leave any Area (Table 13-H) Type Budget 5a Column lineal ft for track Power Exempt Power Total Ltg blanks) (ft') (enter space type only once per room) LPD (b) x (d) ( lighting) (Watts) Fixtures (g) x (h) Power Each room Retail 1085 Retail - Other Merchandise Sales Area 2 2,170 7A1 : j 17 52 ❑ 884 3,892 must be Retail -- - 7A2 -J 4 52 ❑ 208 - identified. Retail - - 782 -J 10 38 ❑ 375 - Descnbe luminaires for each Retail - -- 7C2 - 11 50 ❑ 550 - individual room in Bathroom 52 Restrooms 0 9 47 7C1 - 1 160 ❑ 160 160 plans a 94 Active Storage 0 8 75 7A1 9 9 �� Storage 1 52 ❑ 52 104 Storage - - 7A2 -1 1 52 ❑ 52 - Retail - - 7B2 -! 50 38 O 1,875 3,892 For track lighting Office 64 Office - enclosed 1 1 70 7A2 -i 1 52 ❑ 52 52 enter lineal feet in - - -! - - column column (g) t ❑ - - ^ I { - ❑ - - - - - Column (k), enter ❑ sum of column 0) - - .J - ❑ - for each room only - :l - - once at first entry EE ❑ for the room See - - - ❑ _ example in instructions ❑ - - ') - ❑ - - - - - ❑ - - - - - - I I - ❑ - - - - J - ❑ - - - - - ❑ - - - - - ❑ - - - - -i - ❑ - - - - - - ❑ - - - - 2.J ❑ - - - - - - ❑ - - - - - ❑ - - - - - - ❑ - -- - - - ❑ - - - - - - ❑ - - - - - ❑ - - - - ,: - ❑ - - - - - {{ - ❑ - - - - I - ❑ - - - - J _ ❑ - - - - - _ ❑ - - - - r,1 - ❑ - - - - ,,i ❑ - - - - _, - ❑ - - - - - - ❑ - - - - .-I - ❑ - - 1,295 Worksheet 5b -1 Total Budget 2,362 Wksht 5b -1 Total Lighting Power (excluding exempt/rack fixtures) 1,958 Other Pages Total Number of Additional Worksheet 5b 1 0 -i — List the additional worksheets nece- ssary to catalog all - luminaires in (I) (m) (n) building Lighting Power Budget. Space Proposed Buiding Lighting by -Space only (Total of Power (Total of column (k), Area Sqft (not required Worksheet Number column (e)) excluding exempt/track) for Tenant Method) 5b-1 2,362 1,958 1,295 5b -2 5b-3 Sum of additional 5b worksheets >ti 7. 2,362 1,958 1,295 Total Budget (of all worksheets) w 5 -5 Compliance with OSSC. effective 01/01/05 CITY OF TIGARD i>. BUILDING DIVISION PERMIT #: BUP2007 -00063 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 4/16/2007 Phone: (503) 639 -4171 A Inspection Requests (24 Hrs.): (503) 639 -4175 s' ''' �.. INSPECTION WORKSHEET FOR DATE: 5/23/2007 TIME: 7:00AM PAGE: 55 SITE ADDRESS: 09510 SW WASHINGTON SQUARE RD H -1 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: TRADE SECRET DESCRIPTION: TI , OWNER: WASHINGTON SQUARE LLC, PHONE #: CONTRACTOR: ARCHITECTURAL IN '1 ERIORS & CONST PHONE #: 253.84B•5940 ' Inspection Request Scheduled For: Date: 5/23/2007 Pour Time: Code # Inspection Description Confirm # Contact # Message 267 Suspended coiling 048886 -01 253-820-9634 N Corrections /Comments /Instructions: ❑ PARTIAL APPROVAL n CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: ‘ (A/ Date: 45 / L " 3 / 7 Phone #: (503) 718- Z--12-4 CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2007 000G3 13125 SW Hall Blvd., Tigard, OR 97223 41// DATE ISSUED: 4/16/2007 Phone: (503) 639 -4171 Inspection Requests (24 Hrs.): (503) 639 -4175 INSPECTION WORKSHEET FOR DATE: 5/10/2007 TIME: 7:02AM PAGE: 63 SITE ADDRESS: 09510 SW WASHINGTON SQUARE RD H - 1 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: TRADE SECRET DESCRIPTION: TI OWNER: WASHINGTON SQUARE LLC, PHONE #: CONTRACTOR: ARCHITECTURAL INTERIORS & CONST PHONE #: 263.848.691B • Inspection Request Scheduled For: Date: 5/10 /2007 Pour Ti Code # ' Inspection Description Confirm # Contact # Mr sage 276 Framing 047969 -01 263-020-9634 Y Corrections /Comments /Instructions: PASS n PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED :to Inspector: D ate: `' Phone #: (503) 718 - P ( ) CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2007 -00063 13125 SW Hall Blvd., Tigard, OR 97223 /7/ DATE ISSUED: 4/16/2007 Phone: (503) 639 -4171 I I Inspection Requests (24 Hrs.): (503) 639 -4175 INSPECTION WORKSHEET FOR DATE: 512502007 TIME: 7:17AM PAGE: ' 55 SITE ADDRESS: 09510 SW WASHINGTON SQUARE RD H -1 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: TRADE SECRET DESCRIPTION: Ti OWNER: WASHINGTON SQUARE LLC, PHONE #: CONTRACTOR: ARCHITECTURAL INTERIORS & CONST PHONE #: 253.848-5948 . Inspection Request Scheduled For: Date: 5/2512007 Pour Time: Code # Inspection Description Confirm # Contact # Mes - • 299 Final inspection 049067 -01 253 - 820-9634 IMF 0 Corrections /Comments /Instructions: v Oh_ M Z coo - cDc l p12( te+ l! `� VZA • 00451 - ' -- ❑ PARTIAL APPROVAL • ❑ CANCEL ' ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED � v Inspector: `��` Date: ����� Phone #: (503) 718- �(