Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
q5©9 1//a , i e 0 ( v ©2 Y1r ie a ©0- onSc- q *Titus Submittal AESV -1.0 12 -15 -05 i " The Leader In A!r Management AESV 1 Single Duct Terminal Unit Analog Control, Pressure Independent _—m- L F w F - r i 1 --- 1, . N ( . $ , % - 12 1/4" I • _ L F Fes 61/2 " —J Control Sli 8 Drive Enclosure Cleat Connection / L 18" _1 C Right hand unit shown All dimensions are in inches Inlet Size CFM Range D F G H L M W 4 0 -225 3 7 /8 2 '/e 7 3 /8 8 15 'I 5 3 / 8 12 5 0 -350 4 7 /8 2 ' /8 7 3 /8 8 15 ' /2 5 3 /8 12 6 0 -500 5 7 /8 2 7 3 / 8 8 15 3 3 / 8 12 I r 0-900 7 /8 I le r /8 0 /2 3 ' /8 12 8 0 -900 7 r le 1 '/e 7 3 /8 10 10 15'/2 3 3 !e 12 I J v I Vs... 1./ 1 18 J )e 1) . 12 J 1 8 10 0 -1400 9 - 5 3 /8 12 1 /2 15 1 /2 3 3 / 8 14 12 0 -2000 11 7 /8 - 5 3 / 8 15 15 1 /2 3 3 /8 16 14 0 -3000 13'/ - 3 3 / 8 17 1 / 2 15 '/2 3 3 /8 20 16 0 -4000 15 7 / 8 - 3 3 / 8 18 15 1 /2 3 3 /8 24 24 x 16 0 -8000 23'/8 x 15'/8 1 '/8 5 3 /8 18 15 3 3 /8 38 Accessories (Optional) Ch k Er if provided. 24 V Control Transformer ❑ SteriLoc Liner 12 Bottom Access Door Dust Tight Enclosure Seal ❑ UltraLoc Liner ❑ Disconnect Switch Fibre Free Liner ❑ 1" Fiberglass Liner X Hanger Brackets El General Description • Heavy gauge steel housing • Multipoint center averaging inlet • Electric damper actuator is an Mechanically sealed and velocity sensor, integral part of the unit. gasketed, leak resistant • Electronic proportional room • Model AESV can be installed construction. Less than 2% of thermostat with adjustable horizontally, vertically, or at any nominal cfm at 1.5 sp wg. setpoints for temperature and angle Operation is not affected • Dual density internal insulation, airflow is included with unit. by position. treated to resist air erosion. • Minimum and maximum airflow Meets requirements of NFPA 90A adjustments are made at the and UL 181. thermostat, using a digital • • Rectangular discharge opening is voltmeter. designed for slip and drive cleat • Choice of right hand or left hand duct connection. control location. AESV -2.0 12 -15 -05 Accessories (Optional) ❑ Hot Water Coil Section • 1/2" copper tubes ❑ 1 Row ' • Aluminum ripple fins, 10 per inch ❑ 2 Row O S ti <S' '' • Connections. Single circuit, 1/2" , `'� >%i`',, 2 %,t > O D male solder Multi-circuit, Row H ''r,;>r 2 - rircuil, 7/8" ❑ :)iWe W; z; 0.0 , male solder. ❑ 4 Row I Ci , •; iN• :, �; ,r, ; • Coil is installed at discharge of unit __ • On units with attenuators, coil are installed at the discharge of f -.I W attenuator Electric Coil Section ter Standard Features Options Supply Voltage • Single side access to low voltage, IKFuse Block El 208V, 1 ph, 60Hz high voltage, and electric heater Disconnect switch, door controls ❑ 240V, 1 ph, 60Hz interlock type • Automatic reset thermal cutouts, one ❑ 277V, 1 ph, 60Hz per element El Dust tight construction • Manual reset secondary protection X208V, 3 ph, 60Hz • Positive pressure flow switch ❑ Mercury contactors ❑ 480V 3 ph, 60Hz (4 wire wye standard) • Magnetic contactor for each step • Slip and drive cleat discharge duct 39 —6 1/4 W connection. 39 2 1 I . i 12 d all H I, — 36$ ❑ Integral Sound Attenuator 392 - - 62— W -- . 18 1 12 1 1/4 4 H 1 . 1 Water Coil The total length of the AESV Inlet Size H W 9 L (1 -2 Row) L (3 -4 Row) unit is the summation of the 4 8 12 5 7 /, unit length (with or without 5 8 12 5 7 /, attenuator) and the length of the optional water coil 6 8 12 5 7'/, 7 10 12 5 7'/, 8 10 12 5 7'/, 9 12'/2 14 5 7 /, 10 12'1 14 5 7 12 15 16 5 7 1 /, if 14 17'/ 20 7 1 / 2 9 16 18 24 7 '/ 9 3 /4 24x16 18 38 5 7'/, This submittal is meant to demonstrate general dimensions of this product The drawings are not meant to detail every aspect of the product Drawings are riot to scale Titus reserves the right to make changes without written notice purgeu nc•rv•, NO p•n panic .on cyW •prppuc•e e, uprnr..n•p.n y mvpv • .••NOnr+corm•cn•.k.i ncN,nq pporemprrq pnp r•wronp pr o, y prmsiwnn p •p.• +ncycnm wrm.i inrmnuor n.wni.q lmm pnmliro Y„rninec lnp ter`, MARK: EF -1 COOK c ®us ► I PROJECT: TREAT CENTER DATE: 09 -07 -2007 ACE-D Downblast Centrifugal Exhaust Ventilator Roof Mounted/Direct Drive STANDARD CONSTRUCTION FEATURES: MEM All aluminum housing - Backward inclined all aluminum wheel - Two piece top cap with stainless steel quick release latches (sizes 120 - 180) - Welded curb cap corners - Birdscreen - Permanently lubricated ball bearing motors - Corrosion ilk resistant fasteners - Transit tested packaging. ( I G T Sq Performance _ Dimensions (inches) Catalog Flow SP Fan Input A 2 -1/2 Qty Number (CFM) (Inwc) RPM Watts B 18 -3/4 1 100C15DH 200 .250 869 66 C 16 -13/16 AltitOde (ft): 39 Temperature (F): 70 G 2 Motor Information T Sq. 18 HP RPM Volts/Ph/Hz Enclosure Roof Open. Sq.* 13 -1/2 1/8 1550 115/1/60 ODP Unit Wt(lbs)*** 54 • Roof opening size for subs supplied by Cook only — Includes fan, motor 8 accessories. Sound Data 8 Octave Bands dB (10 - 12 Watts) 1 2 3 4 5 6 7 8 LwA dBA Sones 57 62 55 42 40 35 52 40 _ 2.7 Accessories: Fan Curve STD DISCONNECT 1.25 500 BD-12 DAMPER ROOF CURB RCG 16-9.5 H FAN SPEED CONTROLLER 5 AMP 120 VOLT 1.00 400 0.75 i 300 SP / Input (ice) Watts 0.50 200 • Fan Curve Legend 0.25 CFIVI vs SP (869) _ 1 C vs Watts 100% FSC (1550) 50% FSC (775) • _ 0 00 System Curve — — 0 200 400 600 800 1000 Point of Operation 0 Flow (CFM) v5 4 98 10089 m.lCookwareUOBSIkeithh120071 TITUS TEAMS Single Duct Terminal Unit Selection Project: Quick Select Ta : VAV -01 Project Location: Altitude: 1.0 Feet File temp.tw User: Room: Selection _ Size CFM Static Max NC Levels Quantity Model Unit Outlet Max Min. Heating Inlet Down Min Rad Disch. 1 APS \/ 08 12x10 700 350 350 1 00 0.25 0 04 23 21 Notes' 1 Inlet static pressure includes downstream pressure drop 2 See below for PWL calculations used to obtain Max NC rating 3 Outlet size is approximate and does not include coil dimensions. See submittal drawings for exact dimensions Electric Heating Coil Performance KW Max KW CFM EAT LAT Volts / Ph. Steps 4 0 13.0 350 55 91 208 /3 2 Other Information Accessories MaximumCFM : 900 Outlet: Attenuator Design CFM : 700 Safety Factor: 22% Lining. Fibre Free Unit LxWxH: 16 x 12x 10in seating Coil: Electric Controls: Analog ttenuator: Yes Selected True Acoustic Summary Radiated Sound PWL flischarge Soiinri PWI Sound Description 2 3 4 5 6 7 NC 2 3 4 5 6 7 NC Primary Sound 61 52 44 40 37 32 68 63 54 47 42 39 Total Attenuation P ARI 885 -98 18 19 20 26 31 36 27 29 40 51 53 39 Room Sound Level 43 33 24 14 - - 23 41 34 14 - - - 21 Notes 1 Room sound levels shown include attenuation based on transfer function file Catalog 2. Data were obtained from tests conducted in accordance with ARI Standard 880 - 98. 3 Sound power levels are in decibels, re 10 ^ -12 watts 4 Dash ( -) in space indicates sound and NC value is less than 10 5 Dimensions are for base product only Check submittal drawings for exact dimensions 6 Size units are given in inches, flow units are cubic feet per minute, pressure units are inches of water, and temperature units are degrees fahrenheit The results of this program are only an aid to the designer, and are not a substitute for professional design services. Titus accepts no liability for the adequacy of any resulting design or installation. All data subject to change without notice. Printed 9/10/2007 4 04 25PM Version 4 10 3