Plans (030 bdott5f, 00S 5 eG).ob,S -ooSb 93/� GI/� S� . '�°( Timm Submittal Trane A Division of American Standard Inc. • Pre a re d For: • ( '" Date: Se tember 07 2005 P P Customer P.O. Number: Customer Project Number: Sold To: ' Job Number: Job Name: Chicos @ Washighton Squate Portland CYI1� Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product • 2 BCXC Blower Coil Air Handler The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Roger Coll Trane 6461 Topaz Court Suite 1 Fort Myers, FL 33912 -8311 Phone: (239)275 -9420 Fax: (239)275 -9775 J:IJOBS151215778412109 07 05 Submittal.doc Table Of Contents Product Summary 1 BCXC Blower Coil Air Handler (Item Al) Tag Data 3 Product Data 3 Performance Data 3 Mechanical Specifications 5 Unit Dimensions 7 Fan Curve g Accessory 10 Field Wiring 13 Field Installed Options - Part/Order Number Summary BCXC Blower Coil Air Handler 14 • • Chicos @ Washighton Squate Portland September 07, 2005 Tag Data - BCXC Blower Coil Air Handler (Qty: 2) Item Tag(s) Qty Description Model Number Al AHU -3, AHU-4 2 BCXC Blower Coil Air Handler ( BCHC072G2 * *A1 BCXC) GO7P2075A0B01A J200000K00002 Product Data - BCXC Blower Coil Air Handler Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 HORIZONTAL CONFIGURATION Horizontal Configuration Unit Size 72 -6 Ton (21.1 KW) 460/60/3 Foil Faced Insulation 1" Motor, drive & control box on Same Side as Coil & Drainpan Connection PVC Drainpan - Right Hand Coil & Drainpan Connections 6 Row Cooling Hydronic Coil 3 Horse Power 1029 -1332 RPM 60HZ / 853 -1104 RPM 50HZ 2 - Stage 7.5 KW 24 Volt Magnetic Contactors 2" Pleated Throwaway Filter • Control Interface 2 -Way, 2 Position N.C. (Fld) 6.0(2way) / 7.0 (3way) CV, 1 ", 2 Position, 1" PIPE (Fld) Deluxe Piping Package (Fld) Condensate Overflow & Low Limit Ship Loose Extra 2" Pleated Throwaway. (Fld) Performance Data - BCXC Blower Coil Air Handler Tags AHU -3, AHU-4 Design airflow (cfm) 1800 Total cooling capacity (MBh) 63.93 Sensible capacity (MBh) 46.15 Cooling EDB (F) 80.00 Cooling EWB (F) 67.00 Cooling LDB (F) 56.73 Cooling LWB (F) 55.63 Cooling ent fluid temp (F) 44.00 Cooling leaving fluid temp (F) 56.51 Cooling flow rate (gpm) 10.72 Cooling delta T (F) 12.51 Cooling fluid PD (ft H2O) 1.02 • Cooling face velocity (ft/min) 370 Auxiliary heat type Electric Reheat Aux EAT (F) 50.00 Aux LAT (F) 63.98 Auxiliary total capacity (MBh) 27.24 Unit length (in) 47.000 Unit width (in) 48.000 Unit height (in) 22.000 Installed weight (lb) 250.2 Rigging weight (lb) 223.2 ESP (in H2O) 1.68 TSP (in H2O) 2.40 Fan speed (rpm) 1270 Motor heat calculation Include Piping pkg PD (ft H2O) 11.50 FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 3 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Tags , AHU -3, • AHU-4 Min circuit ampacity (A) 17.16 Coil design basis Cooling Max fuse size (A) 20.00 Main coil type Hydronic Inlet - 63 HZ (dB) 79 Inlet - 125 HZ (dB) 77 Inlet - 250 HZ (dB) 60 Inlet - 500 HZ (dB) 42 • Inlet - 1 kHZ (dB) 35 Inlet - 2 kHZ (dB) 32 Inlet - 4 kHZ (dB) 28 Inlet - 8 kHZ (dB) 19 Casing - 63 HZ (dB) 80 Casing - 125 HZ (dB) 69 Casing - 250 HZ (dB) 66 Casing - 500 HZ (dB) 57 Casing - 1 kHZ (dB) 54 Casing - 2 kHZ (dB) 49 • Casing - 4 kHZ (dB) 44 Casing - 8 kHZ (dB) 38 Discharge - 63 HZ (dB) 95 Discharge - 125. HZ (dB) 87 Discharge - 250 HZ (dB) 75 Discharge - 500 HZ (dB) 69. Discharge - 1 kHZ (dB) 70 Discharge - 2 kHZ (dB) 66 Discharge - 4 kHZ (dB) 64 Discharge - 8 kHZ (dB) 58 Actual motor power (hp) 1.133 Full load amps (A) 4.30 Lock rotor amps (A) 31.00 Outlet velocity (ft/min) 1522 FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 4 of 14 Chicos @ Washighton Squate Portland September 07. 2005 Mechanical Specifications - BCXC Blower Coil Air Handler Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 BCHC General The product line consists of a horizontal air handling unit and mixing box. Units are tested in accordance with ARI 430 -1999 and ARI 260 -2001. The unit is UL 1995 listed in U. S. and Canada and complies with NFPA 90A. Air handlers consist of a hydronic and /or DX coil, drain pan, and centrifugal fan with motor and drive mounted in a common cabinet. Drive location and coil connections are independent for the same or opposite side location. Air handlers are provided with knockouts in all four corners for installing the unit suspended from the ceiling with threaded rods. Unit and accessories are insulated with one -inch, 1% lbs. /cu. ft. density fiberglass insulation. One -inch foil faced insulation is also available. Large motor access panels are provided on both sides of the unit and accessories. Casing Casings (structural components) are constructed of 18 -gauge galvanized steel, insulated with one -inch, 1 1 /2 lb density fiberglass fire resistant and odorless glass fiber material to provide thermal and acoustical insulation. Fan housing sides are directly attached to the air handler top and bottom panels strengthening the entire unit assembly. Coil access panels are located on both sides of the air handler and allow easy removal of the internal coils and drain pan. Main access panels provide generous access to the fan, motor and drive from both sides of the air handler. Foil Faced Insulation The interior surface of the unit is acoustically and thermally lined with 1 inch [26 mm] 2.0 lb. /cu. ft. [32 kgs. /cu. m.], R- Value of 4.3 density glass fiber with a foil facing. The insulation is UL listed and meets NFPA -90A, UL 181, and bacteriological C665 standards. Coil # 1 Hydronic Cooling Coils Cooling coils are two, four, or six -row, chilled water. All water coils are 12 fins per inch. All water coils use highly efficient Trane Delta Flo ?, Type H aluminum fins, mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are factory tested with 450 psi air under water. Maximum standard operating conditions are: 300 psig, 200 °F. Sweat type connections are standard. Electric Heat Stages Factory provided and mounted, UL recognized resistance open -wire heater with a disc -type automatic thermal primary safety device. Two stages of control. Single point power connection to the unit is provided: Optional line fuses and a door interlocking disconnect switch are available. Magnetic Contactors A 24 volt electric heater contact for use with Thermostat Control Interface. Reset Backup Protection • Secondary Manual Reset Backup Protection is provided. Fan - The fans are forward curved, centrifugal blower type equipped with heavy -duty adjustable speed V -belt drives. The fan shaft is supported by heavy -duty, permanently sealed ball bearings. All fans are dynamically balanced. All air handlers have a single fan. 2" [52 mm] Pleated Throw -Away Filter A 2 inch [52 mm] pleated standard efficiency (30 %) throw -away filter(s). 60 Hertz Motor A 60 Hertz, 1750 RPM motor has a plus or minus 10% voltage utilization range. The motor is open drip -proof with permanently sealed ball bearings, internal overload protection, and minimum 1.15 service factor and size 56 resilient base frames. The motor is factory installed and wired to the air handler junction box. Polymer Drain Pan The drain pan is noncorrossive and double - sloped to allow condensate drainage. The drainpan construction is polymer. Coils mount above the drain pan, not in the drain pan - thus allowing the drain pan to be fully inspected and cleaned. The drain pan can also be removed for cleaning. The drain pan connections are unthreaded 3 /4 schedule 40 PVC for solvent bonding. The main drain connection is at the lowest point of the drain pan. An auxiliary drain connection is provided on the same side as the main connection. FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 5 of 14 Chicos @ Washighton Squats Portland September 07, 2005 Thermostat Control Interface The thermostat control interface is intended to be used with a field supplied low voltage thermostat or controller. The control box contains a line voltage to 24 volt transformer and a one, two, or three -pole fan contactor. The wires from the fan contactor and the low voltage side of the transformer are pulled and terminated on the inside of the two -sided terminal strip. The end devices are mounted and the wires are pulled and terminated on the inside of the two -sided terminal strip. All customer connections other than power are on the outside of the two -sided terminal strips. Float Switch A float switch (sometimes referred to as a condensate overflow switch) is a normally closed protection device that opens the circuit when the water level in the drain pan exceeds a certain point'(i.e. auto reset). Freezestat A freezestat is a normally closed protection device that opens the circuit when the entering air temperature to the main coil is below a specific trip temperature. This circuit will not close until the entering air temperature exceeds a - specific release temperature. Deluxe Piping Package - Coil #1 The deluxe piping package consists of one shutoff ball valve, one strainer, one circuit setter balancing valve, and for three -way packages, a balancing fitting on the bypass line. The maximum entering fluid temperature on the water valves is 200 deg. F. [93 deg. C.]. The stop valves are ball type, and insulation on the piping package is by others. 2 -Way, 2 Position Control Valve - Coil #1 -Valve Type 2 -way VU Series or VC Series (Honeywell) -Cv Ranges 3.5, 6.0, 8.0, 9.0 • - Material Body - Forged Brass. Operating Paddle - Patented Buna -N Ball Seat "0" Ring Seals - EPDM. Stem - Brass. - Temperature Limits 200 deg. F [93 deg: C] fluid 125 deg. F [48 deg. C] ambient. - Operating Pressure 300 psi [2068 kpa] max. -Close -off Pressure 20 psi @ 3.5 Cv 60 psi @ 6.0 Cv 9 psi @8.00v 60 psi @9.0Cv 2. Po Actuator - Coil #1 -Drive Time 6 seconds @ 60 Hz. - Voltage 24 VAC 50 & 60 Hz. -Power Consumption 5 watts - Operating Ambient Temperature • 34 to 125 deg. F [15 to 54 deg. C]. FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 6 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Unit Dimensions - BCXC Blower Coil Air Handler Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 NOTE: —.— = AIR FLOW r 46• 1 1 7/8" [22mm[ HANGER ROD KNOCKOUTS 40 " (4 PLACES) FILTER ACCESS 1 '. z 49" . I - — I I 1 - 1 I 22 1/B" ---••- I COIL I MOTOR ACCESS I ACCESS ; PANEL I PANEL I I 4 " - I I I - F T 1/2" • LEFT VIEW 8 L5 WEIGHT lb BASE UNIT 152.2 • TOP VIEW COIL #1 105.6 • COIL #2 1. CONTROL BOX IS PROVIDED WITH 7/8 [22mm[ KNOCKOUTS FOR FIELD WIRING. FILTER ACCESS 8" ONTROL BOX 1" 1" 1 1 17 3/41-12 1/2"7 3/4' 1" I I : i 13 1/2" �- MOTOR ACCESS COIL I PANEL I ACCES ; --.6— 201/8" 14" i 1 I PANEL I I I i 1/2" FRONT VIEW RIGHT VIEW • FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 7 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Unit Dimensions - BCXC Blower Coil Air Handler !tem: Al Qty: 2 Tag(s): AHU -3, AHU-4 NOTE: DRAIN CONNECTION STUBOUTS EXTRUDE 2' (51mml FROM SIDE OF UNIT. RIGHT HAND DRAIN CONNECTIONS /4' SCHEDULE 40 PVC PIPE CONNECTION /I 4 . SCHEDULE 40 PVC PIPE CONNECTION AUX • MAIN DRAIN DRAIN 0 © 2• 1 3/8" I • 103/4' • • 123/4' BOTTOM REAR CORNER OF UNIT GI r1 = F,,michar1 hi, Trans. / Inctallorl by frihP.r.4 Trane Ecuiomant Submittal Pace 8 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Fan Curve - BCXC Blower Coil Air Handler Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 SIZE 54 & 72 HORIZONTAL - • Un�e:72 40 - 50 Ope a� .1�mc*n 25 MO — / \ Opaakg 9ak Reesian2.40n X20 / 0pnaiq RFM121000 — \ - Opera fry flake Power.1.10 3i 5 Ptl de:000 \ / O eagnTenp:B000F 7- '*'":11.1011111111111111MINI — L - 7 .r.,...... r ini fn - - 1ZORPA ilIMM "ii 2 20 t:.-.-. - 111.1111AkTAIN GO MO d — :•Rr7A \ co 0 - 900Ri#A J, �liM �M���, • I— : 2CORA1 -- i 1161 PIMMENNII. Q5 — SCORN _ SOCR.Td _� -� Q . aim \ Qo inatzwilbM 0 1000 2000 310 410 5000 610 7000 810 Airflow 01 . 63- 125- 23:Hz 51Hz 1 kHz 2Id-Iz 41d-Iz 81d-1 Disc 95 87 75 E9 70 66 64 53 Ca;irg 83 69 E6 57 54 49. 44 38 Ira 79 77 a) 42 35 32 28 19 • FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 9 of 14 C @ Washighton Squate Portland September 07, 2005 Accessory - BCXC Blower Coil Air Handler • Right hand electric heater Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 CONTROL PANEL DOOR 7/8' (22mm] CUSTOMER ELECTRICAL WEIGHT lb CONNECTION 17.4 • 1/4' AIR FLOW 12' 1 5 ' 1312' 4 3/8' / 7 6 5/8" • 1 3/8' 18' 1" 1 5/B' 11 5/8' 2 1/4' ISO1 VIEW \\ 1. CONTROL PANEL DOOR IS HINGED AT SIDE. ALLOW FOR CLEARANCE. FLD = Furnished by Trane / Installed by Others Trane Eauioment Submittal Pace 10 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Accessory - BCXC Blower Coil Air Handler 2 way deluxe piping package - coil #1 Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 9 1/4' SUPPLY CONNECTION COIL CONNECTION BALL VALVE STRAINER • 131/4' -v = WATER FLOW CONTROL VALVE � u RETURN CONNECTION COIL CONNECTION - 1 FLOW SETTING VALVE Fl n = Furnished by Trane / Installed by Others Trane Eauioment Submittal Pace 11 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Accessory - BCXC Blower Coil Air Handler COIL 1 = HYDRONIC, COIL 2 = NONE, RH CONNECTIONS Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 COIL CONNECTION SIZE INCH mm RETURN 1 3/8 35 SUPPLY 13/8 35 • SUPPLY O • RETURN O 3' 10' 71/4" • 12 3/4" • \ BOTTOM REAR OF UNIT NOTE: COIL CONNECTION LOCATIONS ARE TOLERANCED WITHIN +/- 2 INCHES (51mm). Fl n = F,imishad by Trans / Installed by Others Trane Eauioment Submittal Page 12 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Field Wiring - BCXC Blower Coil Air Handler Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 NOTES: 1. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC), STATE 8 LOCAL REQUIREMENTS. 2. DASHED UNES INDICATE RECOMMENDED FIELD WIRING BY OTHERS. DASHED UNE ENCLOSURES BJOR DASHED DEVICE OUTLINES INDICATE COMPONENTS PROVIDED BY OTHERS. . SOUP LINES INDICATE WIRING BY TRANE CO. • 3. CONTROL WIRING CONNECTIONS ARE B-32 SCREW 460/60/3 TERMINALS LOCATED ON OUTSIDE OF CONTROL BOX LI L2 L3 4. LINE VOLTAGE CONNECTIONS ARE TO BE SPUCED TO WIRES INSIDE OF UNIT CONTROL BOX OR TERMINATED CONNECTIONS INSIDE INSIDE OF ELECTRIC HEAT CONTROL BOX ON UNITS ELECTRIC HEAT CONTROL 1 WITH ELECTRIC HEATERS. BOX . . WARNING it AVERTISSEMENT e ADVERTENCIA WIRINPOWER HAZARDOUS VOLTAGE TENSION D»NGEREUSE VOLTAIE PELIGROSO! OCCO.KT ALL 5ECIAC RORER =OE, TONES LES 1110011 ET _ DESOOMECIE =ILI EK011■ ELLCTRC& MOLLOEO RB.QIE 0EOMPCCTS CARE LOS 5ECI10NEWA DETMCE. M100 LAS 0ESOOLELCK4 ROOMS MO POLLOM LCOL OUT MO WS PUS SUM 113 PROCEDURES CC SCA LDS PROCLDMEMOS DE COW Y PRODEOLSLIS ECfORE SERYCM6. VERIOULLACE CT DES EiOLCTIE S AVANT E1OL0TA10AN1E S DERIOCEDER Al j j cAdid ]RIVE 06dMGED COOUBA1 CIS WRIER iGTORES OMLTTI SR ■2504 0 l� b L1 STORED VOLTAGE. WTI NCR MIRIA 113. CAM LE CAS0LER13 ,DESCAAGAW ELVCTA,CMAIACENADO WANK! SPEED DM/[ RESTA CCL0ORTNR DES EMRAOEMERIS A RUM US WDIOES WY en CC TO Cant INSTRJClt10 SCR vms0VUUSC. SE REFORM AA DEEIDM. Ce VELavwvaaAaE. / / / 0 0 0 CANQIORD60W12 MSIRUCTI00 CONSUL lELAS MSTRUCCO119 PAPAL 1P/LRE 7000 TN! a0 /! DEOUAGER LESCQOET1LLTDIRS. DESCARGA DELCOCEI0*OCL SEEM SERVCSOCOAD MERUT K PIS RLSP0112 as WARES DE n RO rtALe. LOMPrznailNTE EQUIPMENT TERMINAL 11 00.55,/0 SER00 11AAM. PRE-CA/MN REM BPSAMBL KS MOCAOO. SCORIA La AEERTE GROUND BLaLAES M AWS POUVANT EI RE o SEAMS LUCKSRERSOMAES. BLO • UNIT CONTROL BOX FIELD SUPPLIED CONTROLLER TERMINAL BLOCK 24VAC. 15VA MAX. ' 17E15 -1 I —C I H t I OPEN - DAMPER ACTUATOR 1782-4 � O 1_1 I CLOSE - DAMPER ACTUATOR 1762 - 0 EXHAUST FAN EXHAUST FAN RELAY 1785 -2 I o 0 • 24VAC. 2VA MAX 1783 - OPEN - COIL #2 VALVE/ I ELECTRIC HEAT 131 STAGE 0 CLOSE - COIL #2 VALVE/ 1T B3-2 • ELECTRIC HEAT 2nd STAGE 0 • FAN - HIGH SP EED 1783 -6 I y I 0 • H I FAN -LOW SPEED 1783 -3 1TB5-2 ' 24V O O��CF�< COIL #1VLV H I OPEN - COIL set VALVE 1TB3 -4 1TB3 -4 ON /OFF O O —( E--( (—(( NA MAX H I CLOSE - COILPI VALVE 1TB3-5 1TB5-1 COM O o—< E ---( E< CAUTION PRECAUCION ATTENTION USE COPPER CONDUCTORS ONLY! N'UTILISER OUE DES CONDUCTEURS EN CUIVRE! IUTILICE ONICAMENTE CONDUCTORES DE COBRE! • UNIT TERMINALS AAE NOT DESIGNED TO ACCEPT LES BORNES DE L•UNITE NE SONT PAS CONgUES LAS TERMINALES DE LA UNICAD NO ESTAN DISENADAS OTHER TYPES OF CONDUCTORS. POUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. PARA ACEPTAR OTROS TIPOS DE CONDUCTORES. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE LVTILISATION DE TOUT AUTRE CONDUCTEUR PEAT SI NO LO MACE, PUEDE OCASIONAR DANO AL EOUIPO. EOUIPMENT. ENOOMM■GER L'EOUIPEMENT. FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 13 of 14 Chicos @ Washighton Squate Portland September 07, 2005 . Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family - BCXC Blower Coil Air Handler Item Tag(s) Qty Description Model Number Al AHU -3, AHU-4 2 BCXC Blower Coil Air Handler ( BCHC072G2 * *A1 BCXC) GO7P2075A0B01A J200000K00002 Field Installed Option Description Part/Ordering Number Deluxe Piping Package 6.0(2way) / 7.0 (3way) CV, 1 ", 2 Position, 1" PIPE 2 -Way, 2 Position N.C. Ship Loose Extra 2" Pleated Throwaway. FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 14 of 14