Loading...
Plans ?"3,30 Oct.5156R� e� � ° - 005�6s �VIeG1ouS - o 0 S b c/3 / l�/ S �°I' TRINE Submittal Trane A Division of American Standard Inc. Prepared For: 73 -(.) Date: September 07, 2005 Customer P.O. Number: Customer Project Number: Sold To: Job Number: Job Name: • Chicos @ Washighton Squate Portland Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 2 BCXC Blower Coil Air Handler The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Roger Coll Trane 6461 Topaz Court Suite 1 Fort Myers, FL 33912 -8311 Phone: (239)275 -9420 ' Fax: (239)275 -9775 .. • J:IJOBS151215778412109 07 05 Submittal.doc Table Of Contents Product Summary 1 BCXC Blower Coil Air Handler (Item Al) Tag Data 3 Product Data 3 Performance Data 3 Mechanical Specifications 5 Unit Dimensions 7 Fan Curve 9 Accessory 10 Field Wiring 13 Field Installed Options - Part/Order Number Summary BCXC Blower Coil Air Handler 14 _J Chicos @ Washighton Squate Portland September 07, 2005 Tag Data - BCXC Blower Coil Air Handler (Qty: 2) Item Tag(s) Qty Description Model Number Al AHU -3, AHU-4 2 BCXC Blower Coil Air Handler ( BCHC072G2 * *A1 BCXC) GO7P2075A0B01A J200000K00002 Product Data - BCXC Blower Coil Air Handler Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 HORIZONTAL CONFIGURATION Horizontal Configuration UnitSize72- 6Ton(21.1 KW) 460/60/3 Foil Faced Insulation 1" Motor, drive & control box on Same Side as Coil & Drainpan Connection PVC Drainpan - Right Hand Coil & Drainpan Connections 6 Row Cooling Hydronic Coil 3 Horse Power 1029 -1332 RPM 60HZ / 853 -1104 RPM 50HZ 2 - Stage 7.5 KW 24 Volt Magnetic Contactors • 2" Pleated Throwaway Filter Control Interface 2 -Way, 2 Position N.C. (Fld) 6.0(2way) / 7.0 (3way) CV, 1 ", 2 Position, 1" PIPE (FId) Deluxe Piping Package (FId) Condensate Overflow & Low Limit Ship Loose Extra 2" Pleated Throwaway. (FId) Performance Data - BCXC Blower Coil Air Handler Tags AHU -3, AHU-4 Design airflow (cfm) 1800 Total cooling capacity (MBh) 63.93 Sensible capacity (MBh) 46.15 Cooling EDB (F) 80.00 Cooling EWB (F) 67.00 Cooling LDB (F) 56.73 Cooling LWB (F) 55.63 Cooling ent fluid temp (F) 44.00 Cooling leaving fluid temp (F) 56.51 Cooling flow rate (gpm) 10.72 Cooling delta T (F) 12.51 Cooling fluid PD (ft H2O) 1.02 Cooling face velocity (ft/min) 370 Auxiliary heat type Electric Reheat Aux EAT (F) 50.00 Aux LAT (F) 63.98 Auxiliary total capacity (MBh) 27.24 Unit length (in) 47.000 Unit width (in) 48.000 Unit height (in) 22.000 Installed weight (lb) 250.2 Rigging weight (lb) 223.2 ESP (in H2O) 1.68 TSP (in H2O) 2.40 Fan speed (rpm) 1270 Motor heat calculation Include Piping pkg PD (ft H2O) 11.50 FLD = Furnished by Trane /installed by Others Trane Equipment Submittal Page 3 of 14 • ...S1=10 Washighton Squate Portland September 07, 2005 Tags , AHU -3, AHU-4 Min circuit ampacity (A) 17.16 Coil design basis Cooling Max fuse size (A) 20.00 Main coil type Hydronic Inlet - 63 HZ (dB) 79 Inlet - 125 HZ (dB) 77 Inlet - 250 HZ (dB) 60 Inlet - 500 HZ (dB) 42 Inlet -1 kHZ (dB) 35 Inlet - 2 kHZ (dB) 32 Inlet - 4 kHZ (dB) 28 Inlet - 8 kHZ (dB) 19 Casing - 63 HZ (dB) 80 Casing - 125 HZ (dB) 69 Casing - 250 HZ (dB) 66 Casing - 500 HZ (dB) 57 Casing - 1 kHZ (dB) 54 Casing - 2 kHZ (dB) 49 • Casing - 4 kHZ (dB) 44 Casing - 8 kHZ (dB) 38 Discharge - 63 HZ (dB) 95 Discharge - 125 HZ (dB) 87 Discharge - 250 HZ (dB) 75 Discharge - 500 HZ (dB) 69 Discharge - 1 kHZ (dB) 70 Discharge - 2 kHZ (dB) 66 Discharge - 4 kHZ (dB) 64 Discharge - 8 kHZ (dB) 58 Actual motor power (hp) 1.133 Full load amps (A) 4.30 Lock rotor amps (A) 31.00 Outlet velocity (ft/min) 1522 FLD = Fumished by Trane / Installed by Others Trane Equipment Submittal Page 4 of 14 Chicos (a? Washighton Squate Portland September 07, 2005 Mechanical Specifications - BCXC Blower Coil Air Handler Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 BCHC General The product line consists of a horizontal air handling unit and mixing box. Units are tested in accordance with ARI 430 -1999 and ARI 260 -2001. The unit is UL 1995 listed in U. S. and Canada and complies with NFPA 90A. Air handlers consist of a hydronic and /or DX coil, drain pan, and centrifugal fan with motor and drive mounted in a common cabinet. Drive location and coil connections are independent for the same or opposite side location. Air handlers are provided with knockouts in all four corners for installing the unit suspended from the ceiling with threaded rods. Unit and accessories are insulated with one -inch, 11/2 lbs. /cu. ft. density fiberglass insulation. One -inch foil faced insulation is also available. Large motor access panels are provided on both sides of the unit and accessories. Casing Casings (structural components) are constructed of 18 -gauge galvanized steel, insulated with one -inch, 1 1 /2 lb density fiberglass fire resistant and odorless glass fiber material to provide thermal and acoustical insulation. Fan housing sides are directly attached to the air handler top and bottom panels strengthening the entire unit assembly. Coil access panels are located on both sides of the air handler and allow easy removal of the internal coils and drain pan. Main access panels provide generous access to the fan, motor and drive from both sides of the air handler. • Foil Faced Insulation The interior surface of the unit is acoustically and thermally lined with 1 inch [26 mm] 2.0 lb. /cu. ft. [32 kgs. /cu. m.], R- Value of 4.3 density glass fiber with a foil facing. The insulation is UL listed and meets NFPA -90A, UL 181, and bacteriological C665 standards. Coil # 1 Hydronic Cooling Coils Cooling coils are two, four, or six -row, chilled water. All water coils are 12 fins per inch. All water coils use highly efficient Trane Delta Flo ?, Type H aluminum fins, mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are factory tested with 450 psi air under water. Maximum standard operating conditions are: 300 psig, 200 °F. Sweat type connections are standard. Electric Heat Stages Factory provided and mounted, UL recognized resistance open -wire heater with a disc -type automatic thermal primary safety device. Two stages of control. Single point power connection to the unit is provided: Optional line fuses and a door interlocking disconnect switch are available. Magnetic Contactors A 24 volt electric heater contact for use with Thermostat Control Interface. Reset Backup Protection . Secondary Manual Reset Backup Protection is provided. Fan - The fans are forward curved, centrifugal blower type equipped with heavy -duty adjustable speed V -belt drives. The fan shaft is supported by heavy -duty, permanently sealed ball bearings. All fans are dynamically balanced. All air handlers have a single fan. 2" [52 mm] Pleated Throw -Away Filter A 2 inch [52 mm] pleated standard efficiency (30 %) throw -away filter(s). 60 Hertz Motor A 60 Hertz, 1750 RPM motor has a plus or minus 10% voltage utilization range. The motor is open drip -proof with permanently sealed ball bearings, internal overload protection, and minimum 1.15 service factor and size 56 resilient base frames. The motor is factory installed and wired to the air handler junction box. Polymer Drain Pan The drain pan is noncorrossive and double - sloped to allow condensate drainage. The drainpan construction is polymer. Coils mount above the drain pan, not in the drain pan - thus allowing the drain pan to be fully inspected and cleaned. The drain pan can also be removed for cleaning. The drain pan connections are unthreaded'/" schedule 40 PVC for solvent bonding. The main drain connection is at the lowest point of the drain pan. An auxiliary drain connection is provided on the same side as the main connection. FLD = Furnished by Trane /Installed by Others Trane Equipment Submittal Page 5 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Thermostat Control Interface The thermostat control interface is intended to be used with a field supplied low voltage thermostat or controller. The control box contains a line voltage to 24 volt transformer and a one, two, or three -pole fan contactor. The wires from the fan contactor and the low voltage side of the transformer are pulled and terminated on the inside of the two -sided terminal strip. The end devices are mounted and the wires are pulled and terminated on the inside of the two -sided terminal strip. All customer connections other than power are on the outside of the two -sided terminal strips. Float Switch A float switch (sometimes referred to as a condensate overflow switch) is a normally closed protection device that opens the circuit when the water level in the drain pan exceeds a certain point'(i.e. auto reset). Freezestat A freezestat is a normally closed protection device that opens the circuit when the entering air temperature to the main coil is below a specific trip temperature. This circuit will not close until the entering air temperature exceeds a specific release temperature. Deluxe Piping Package - Coil #1 The deluxe piping package consists of one shutoff ball valve, one strainer, one circuit setter balancing valve, and for three -way packages, a balancing fitting on the bypass line. The maximum entering fluid temperature on the water valves is 200 deg. F. [93 deg. C.]. The stop valves are ball type, and insulation on the piping package is by others. 2 -Way, 2 Position Control Valve - Coil #1 -Valve Type 2 -way VU Series or VC Series (Honeywell) -Cv Ranges 3.5, 6.0, 8.0, 9.0 - Material Body - Forged Brass. Operating Paddle - Patented Buna -N Ball Seat "0" Ring Seals - EPDM. Stem - Brass. - Temperature Limits 200 deg. F [93 deg. C] fluid 125 deg. F [48 deg. C] ambient. - Operating Pressure 300 psi [2068 kpa] max. -Close -off Pressure 20 psi @ 3.5 Cv 60 psi @ 6.0 Cv 9 psi @8.00v 60 psi @9.00v 2 Position Actuator - Coil #1 -Drive Time 6 seconds @ 60 Hz. - Voltage 24 VAC 50 & 60 Hz. -Power Consumption 5 watts - Operating Ambient Temperature 34 to 125 deg. F [15 to 54 deg. C]. FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 6 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Unit Dimensions - BCXC Blower Coil Air Handler Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 NOTE: —v = AIR FLOW 46" 1 1 7/8' 122mm1 HANGER ROD KNOCKOUTS g. (4 PLACES) FILTER ACCESS 1 r. 49' I : — I I I I I 22 1/8' --•.— i COIL I MOTOR ACCESS I _� ACCESS ; PANEL I PANEL I I 4 I I I II 7 9 1/2' • 0 i LEFT VIEW i L5J WEIGHT . lb BASE UNIT 152.2 TOP VIEW COIL #1 105.6 COIL #2 1. CONTROL BOX IS PROVIDED WITH 7/6" (22mm1 KNOCKOUTS FOR FIELD WIRING. FILTER ACCESS 8" ONTROL BOX 1" 1" 173/4'12 1/2'--1 3/4' 11' I I — 1 131/2" __ MOTOR ACCESS COIL ; i PANEL ; ACCESS �— 201/8' 14' i i PANEL I I I 1 1/2" FRONT VIEW RIGHT VIEW FLD = Furnished by Trane /Installed by Others Trane Equipment Submittal Page 7 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Unit Dimensions - BCXC Blower Coil Air Handler !tem: Al Qty: 2 Tag(s): AHU -3, AHU-4 NOTE: DRAIN CONNECTION STUBOUTS EXTRUDE 2" [51mmi FROM SIDE OF UNIT. • RIGHT HAND DRAIN CONNECTIONS /4" SCHEDULE 40 PVC PIPE CONNECTION /4' SCHEDULE 40 PVC PIPE CONNECTION AUX MAIN DRAIN DRAIN © T 2" 1 3IB" • 103/4' 12 3/4' BOTTOM REAR CORNER OF UNIT GI 11 = F,tmichcrl by Tramp / Inctallarl by ()them Trane Eauimmpnt Submittal Paoe 8 of 14 Chicos @ Washlghton Squate Portland September 07, 2005 Fan Curve - BCXC Blower Coil Air Handler ,Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 SI7I 54 & 72 HORIZONTAL Un @e:72 A O 50 OperaY•9AN,r.1B0000c n ` 7� iM0 _ Cbdai+p Oak u Preeee: _ \' \ \ Openig RFM 177000 , MOM \ 0peraba Bake Powc 1.10 35 :oCO D eepn Tenp:8000F — Dab:9!/,06 - MORPH 1 _ \� , % \ A9e0 = 30 _ TS00R�1 2 25 N _ MORIN rajIMII-IaIIIMI � \ \ M II m d._�R�II�� 90 MO ■ - �R��,��►AR►TA =1i 0 1. _ H 05 - - 600RTA = 470R�1 _� =. = _%�-� 00 = 0 10J0 2000 310 410 5000 EOCO 7000 810 /WON (dirt) 63-1z 125•i -lz 25C]-iz 5I1-Iz 1Id-z 2Idiz 4{d-$z 8Id-!z CisctErw 95 87 75 EG ' 70 E6 64 53 Ca§m 80 E9 E6 57 54 49 44 38 Irid 79 77 EO 42 35 32 28 • 19 • • FLO = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 9 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Accessory - BCXC Blower Coil Air Handler Right hand electric heater Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 CONTROL PANEL DOOR 7/8" (22mm] CUSTOMER ELECTRICAL WEIGHT lb CONNECTION 17.4 1/4' Al 4400 R 4 FLO 1/2 1 3/8" 3 5/8' 131/2' 6 5/8" 13 Y 18' 1" 1 5/8' 11 5/:' 2 1/4" ISO1 VIEW 1. CONTROL PANEL DOOR IS HINGED AT SIDE. ALLOW FOR CLEARANCE. FLD = Furnished by Trane / Installed by Others Trane Eauioment Submittal Pace 10 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Accessory - BCXC Blower Coil Air Handler 2 way deluxe piping package - coil #1 Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 9 1/4" SUPPLY CONNECTION COIL CI!TIONBAIVIVE STRAINER 131/4" —� = WATER FLOW CONTROL VALVE - RETURN CONNECTION COIL CONNECTION FLOW SETTING VALVE F! n = Furnished by Trane / Installed by Others Trane Eauiament Submittal Paae_ 11 of 14 Chicos @ Washighton Squate Portland September 07, 2005 • Accessory - BCXC Blower Coil Air Handler COIL l = HYDRONIC, COIL 2 = NONE, RH CONNECTIONS Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 COIL CONNECTION SIZE INCH mm RETURN 13 35 SUPPLY 13/8 35 SUPPLY RETURN O 3' 10' 7 1/4' - _ 12 3/4" \ BOTTOM REAR OF UNIT NOTE: COIL CONNECTION LOCATIONS ARE TOLERANCED WITHIN +/- 2 INCHES (51mm). F! n = Fnmichcd by Trane /Installed by Others Trane Eauioment Submittal Page 12 of 14 Chicos © Washighton Squate Portland September 07, 2005 Field Wiring - BCXC Blower Coil Air Handler 1 Item: Al Qty: 2 Tag(s): AHU -3, AHU-4 . NOTES: 1. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC). STATE & LOCAL REQUIREMENTS. 2. DASHED LINES INDICATE RECOMMENDED FIELD WIRING BY OTHERS. DASHED LINE ENCLOSURES 6/OR DASHED DEVICE • OUTLINES INDICATE COMPONENTS PROVIDED BY OTHERS. SOLID LINES INDICATE WIRING BY TRANS CO. 460/60/S ' 3. CONTROL WIRING CONNECTIONS ARE 6-32 SCREW . TERMINALS LOCATED ON OUTSIDE OF CONTROL BOX U L2 L3 4. LINE VOLTAGE CONNECTIONS ARE TO BE SPLICED TO - ' WIRES INSIDE OF UNIT CONTROL BOX OR TERMINATED i I 1 CONNECTIONS INSIDE INSIDE OF ELECTRIC HEAT CONTROL BOX ON UNITS ELECTRIC HEAT CONTROL • WITH ELECTRIC HEATERS. — I BOX Q WARNING 8 AVERTISSEMENT 8 ADVERTENCIA I POWER i WIRING HAZARDOUS VCLTAGE TENSICN OANOEREUSE IVOLTAJE PELIGROSO! OCCotECT MI EIECTNC RDACR . COAER MUMS US TEHSOO CT DCSTXNECTE IOMLAVERGIANECDICA tommaREltlrt oam.e0n amanita SCCIOHtemsAGOTMR'L NOM. LAS DESCOROIOHES ROAST. Y NO FCLLCAY LOOT OUT AIO TAO PUS PAWL LAS PROCEDURES DE SCA LOS PRODEDUEMTDS DE COREY PROCEDMIES SUCRE SCICVCEO. WNOASIADC ET DES EIO.ZTTCS AVANT CDOLETADOAACS CC PROCEDERAL OCC MUM ETAT WAOt S K MOOR= US CCKOBATELRS DES r MOTSIAS � LOS CAP DE DE IM S 0 b 6 b STORED VOTADG USES NEN DCOVWDEA DANS Le CAS Dulles ,DESCAAGDO CL UMTAL ALAMCEHA O. VARII$E SPEED OM% MAU CagDRTAHT EIS EMNAPAPEM S A IMPALAS INOSDCS CDV ESE a TO CAM NOTRUC1D13 ROR WEISS PARAELA. SC IMPORTER Ma DRECOW 0YELauwVANw.e. / / / 0 0 0 CAPACJTOR SCTRUGIp0DS LTATIUMEOA POUR COIELATE LAS NS1RI.lLO1¢S PARALA FALIAE TO CO DE AEO.S DCOWCLAIESCDOOC 1E1K4. DCSCARGA OELCOOEAG4 SOME P -GOAD REACT IC PAS RESPECTER CU LEAVES Ce EL AO LOAH1EROIMEHTE EQUIPMENT TERMINAL SERVC N DEATH CC SUM. KS_, PREOM„OIPEUTCNTRAPRR MS MOCADS. PDDRM DCASOISIC LA WARM GROUND RLSAneS GRAMS POwMA tin o SERVS LEVOSS PCRSOHYe1 BLOCK UNIT CONTROL BOX FIELD SUPPLIED CONTROLLER TERMINAL BLOCK 24VAC. 15VA MAX 1785 -1 --.0 I I OPEN - DAMPER ACTUATOR 1782'4 I -- 1 O CLOSE - DAMPER ACTUATOR 1TB2 -5 r I 0 EXHAUST FAN RELAY 1785 - I 1 EXHAUST FAN O O ! 24VAC, 2VA MAX OPEN • • COIL #2 VALVE/ 1TB3 - E — I I ELECTRIC HEAT 1st STAGE 0 • I CLOSE - COIL #2 VALVE/ 1TB3 -2 I i � I ELECTRIC HEAT 2nd STAGE 0 II H I F AN • HIGH SPEED 1783 -6 • O 1 I FAN - LOW SPEED 1TB3 -3 1785 -2 24V � 0 < <----“---< COIL #1VLV IOPEN - COIL#I 1TB3-4 1TB3-4 ON /OFF TVA MAX 0 o— <F —< (----<( l y 1. CLOSE • COIL #1 VALVE 17o 5 17855<E- < —<( COM • • • CAUTION PRECAUCION ATTENTION USE COPPER CONDUCTORS ONLY! NUTIUSER CUE DES CONDUCTEURS EN CUIVRE! IUTIUCE ONICAMENTE CONDUCTORES DE COBREI UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT LES BORNES DE LSJNITE NE SONT PAS CONCUES LAS TERMINALES DE LA UNIOAD NO ESTAN DISENADAS OTHER TYPES OF CONDUCTORS. POUR RECEVOIR D'AUTRES TYPES OE CONDUCTEURS. PARA ACEPTAR OTROS TIPOS DE CONDUCTORES. FAILURE TO DO SO MAY CAUSE DAMAGE TO THE LLTILISATION DE TOUT AUTRE CONDUCTEUR PERT SI NO LO MACE, PUEDE OCASIONAR DANO AL EOUIPO. EQUIPMENT. ENOOMMAGER L'EQUIPEMENT. FLD = Furnished by Trane / Installed by Others Trane Equipment Submittal Page 13 of 14 Chicos @ Washighton Squate Portland September 07, 2005 Feld Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family - BCXC Blower Coil Air Handler Item Tag(s) Qty Description Model Number Al AHU -3, AHU-4 2 BCXC Blower Coil Air Handler ( BCHC072G2 * *A1 BCXC) GO7P2075A0B01A J200000K00002 Field Installed Option Description Part/Ordering Number Deluxe Piping Package 6.0(2way) / 7.0 (3way) CV, 1 ", 2 Position, 1" PIPE 2 -Way, 2 Position N.C. Ship Loose Extra 2" Pleated Throwaway. FLD = Furnished by Trane I Installed by Others Trane Equipment Submittal Page 14 of 14