Correspondence • ///OVIN414 � �� .t\ October 18, 2005 1 CITY OF TIGARD OREGON Footlocker C/O Express Permits Cynthia Thornton 1327 Post Ave. # H Torrance, CA 90501 RE: FOOTLOCKER - REVIEW Project Information Building Permit: BUP2005 -00434 Construction Type: 11 -B Tenant Name: Footlocker Occupancy Type: M Address: 9459 SW Washington Sq Occupant Load: 93 Area: 3,755 sq ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2003 International Fire Code as amended by TVF &R. The submitted plans are approved subject to the following conditions. NOT PART OF THIS REVIEW: * Electrical * Mechanical * Plumbing 1. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. 1011.1 OSSC 2. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1008.1.8 OSSC 3. Exit signs shall be illuminated at all times and shall be provided with a second source of power that will provide 1 '/2 hours of illumination in case of primary power loss. 1006.3 OSSC FYI Additional exit signs may be required by the city field inspector to clearly indicate the path of egress. 4. Accessible checkout aisles shall be on an accessible route and at least 36 inches wide. Counters in accessible checkout aisles shall be not more than 38 inches (965 mm) high and the top of the raised edge of the counter shall not exceed 40 inches (1016 mm) in height above the finished floor. Accessible checkout aisles shall be identified by the international symbol of access. OSSC section 1109.19, 1109.23.3 . 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 5. American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 110.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, ' �zl Val Henze!, Senior Plans Examiner /�oura�Ngp ��� September 7, 2005 �''� CITY OF TIGARD OREGON Footlocker C/O Express Permits Cynthia Thornton 1327 Post Ave. # H Torrance, CA 90501 RE: FOOTLOCKER - REVIEW Project Information Building Permit: BUP2005 -00434 Construction Type: II -B Tenant Name: Footlocker Occupancy Type: M Address: 9459 SW Washington Sq Occupant Load: 93 Area: 3,755 sq ft Stories: 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2003 International Fire Code as amended by TVF &R. The following information is required in order to complete the review. PRELIMINARY REVIEW 1. Provide framing details showing all construction details of work being done at front entry. NOT PART OF THIS REVIEW: * Electrical * Fire Sprinklers * Fire Alarms * Mechanical System * Plumbing When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the docum nts. \ Respe «.. 1 y � J ��� Y \I 111 V .1 ' enzel J v Senior Plans Examiner ` ( f \26.Y b V sA & . 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 •