Correspondence March 27, 2006 1 CITY OF TIGARD OREGON Western Design Group Veleta Gee 4612 NE Minnehaha St Vancouver, WA 98661 RE: REVIEW - TENANT ALTERATION Project Information Building Permit: BUP2006- 100018 Construction Type: H B Tenant Name: Pottery Barn Kids Occupancy Type: B Address: 9467 SW Washington Sq Occupant Load: 20 Area: 986 sq ft Stories: ' 1 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2003 International Fire Code as amended by TVF&R The submitted plans are approved subject to the following conditions. 1. Deferred submittals such as Fire Alarm, Fire Sprinkler, Truss Joist Shop Drawings, etc, will be charged a deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee shall be $200.00. 2. NOT PART OF THIS REVIEW: • Fire Sprinklers and /or fire alarms • Mechanical System • Plumbing • Electrical 3. Provide one 2 -A rated fire extinguisher in storage area. The extinguisher shall be located so that no usable space has a distance greater than 75 feet to the extinguisher. OFC 906.3 4. Safety glazing including but not limited to: the following locations: Each unit of glazing shall be permanently identified by the manufacturer. 2406 OSSC. Some of these locations are as follows: a. Glazing in ingress and means of egress doors. b. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24" arc of the door in a closed position and whose bottom edge is less than 60" above the floor or walking surface except when there is an intervening wall or other permanent barrier between the door and the glazing. c. Glazing that meets all the following conditions: In lieu of safety glazing, protective bar (1 ' /2" height minimum) may be installed on the accessible side(s) of the glazing 36" ± 2" 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 i above the floor. The bar shall be capable of withstanding a horizontal load of 50 plf without contacting the glass. Sec. 308.4 5. Accessible checkout aisles shall be on an accessible route and at least 36 inches wide. Counters in accessible checkout aisles shall be not more than 38 inches (965 mm) high and the top of the raised edge of the counter shall not exceed 40 inches (1016 mm) in height above the finished floor. Accessible checkout aisles shall be identified by the international symbol of access. Sec. 1109.19, 1109.23.3 6. Doors to unisex toilet and bathing rooms shall be securable from within the room and be provided with a privacy lock and an "occupied" indicator. 1109.10.114 OSSC 7. Floor drains shall not be located within the clear floor space at a lavatory, water closet, urinal, or bathtub or shower. Floors shall not slope in excess of 1 unit vertical in 50 units horizontal (2- percent slope). Floor drains shall comply with Section 1109.4.5 and be without abrupt changes of level. Exception: Floor drains may be located within a clearfloor space at a fixture provided the openings in the drain over shall not exceed 1/2 inch (12.7 mm) in any direction and the drain cover shall be no more than 1 /8 inch below the level of the surmundingfinished floor surface. 1109.10.1 OSSC 8. American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has issued a certificate of occupancy 110.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Val Henzel, Senior Plans Examiner