Correspondence City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223
Tfe S ti � n ' hj-:, , r ��:
i1 �y� t��'F
q
; it �
April 11, 2007 i'' ®' '
AMettnal
RE: MAGGIE MOO'S /AUNTIE ANNE'S TENANT IMPROVEMENT
Project Information
Building Permit: BUP2007 -00121 Construction Type: IIN
Address: 9469 SW Washington Sq. Occupancy Type: M
Area: 1527 sq. ft. Stories: 1
The plan review was performed under the State of Oregon Structural Specialty
Code (OSSC) 2004 edition; 2005 edition and the Tualatin Valley Fire & Rescue
Ordinance 99 -01 (TVFR99 -01) 1999 edition.
1) Engineering for walls and ceilings see 8 1 /2 X 11 engineering sheets.
FIRE LIFE AND SAFETY / GENERAL
The main exterior door or doors are permitted to be equipped with key- operated
locking devices from the egress side provided:
1. The locking device is readily distinguishable as locked,
2. A readily visible durable sign is posted on the egress side on or adjacent to
the door stating THIS DOOR TO REMAIN UNLOCKED WHEN
BUILDING IS OCCUPIED.
The sign shall be in letters 1 inch (25 mm) high on a contrasting background. (Sec.
1008.1.8.3)
All exit doors shall be openable from the inside without the use of a key or any
special knowledge or effort. (Sec. 1008.1.8)
Exits and exit access doors shall be marked by an approved exit sign readily visible
from any direction of egress travel.
Access to exits shall be marked by readily visible exit signs in cases where the exit
or the path of egress travel is not immediately visible to the occupants. (Sec.
1011.1)
Exit signs shall be illuminated at all times and shall be provided with a second
source of power that will provide 1 1 /2 hours of illumination in case of primary
power loss. (Sec. 1006.3) FYI
Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772
Additional exit signs may be required by the city field inspector to clearly indicate
the path of egress.
The means of egress shall be provided with illumination of not less than 1 foot
candle at the floor level anytime the building is occupied. The means of egress
illumination shall be provided with a second source of power in case of primary
power loss. (Sec. 1006.2)
Live Loads Posted: The live loads for which each floor has been designed to
exceed 50 psf shall be conspicuously posted by the owner in that part of each story
in which they apply, using durable metal signs, and it shall be unlawful to remove
or deface such notices. The occupant of the building shall be responsible for
keeping the actual load below the allowable limits. (1603.3 OSSC)
American with Disabilities Act (ADA): It shall be the responsibility of the
Architect, Engineer, Designer, Contractor, Owner and Lessee to research the
applicability of the ADA requirements for the structure. The City of Tigard
reviews the plans and inspects the structure only for compliance with Chapter 11
of the OSSC, which may not include all of the requirements of the ADA.
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval
stamp, shall be maintained on the jobsite. The plans shall be available to the
Building Division inspectors throughout all phases of construction. (106.3.1
OSSC)
Certificate of Occupancy: No building or structure shall be used or occupied
until the Building Official has issued a certificate of occupancy (109.1 OSSC)
Premises Identification: Approved numbers or addresses shall be provided for
all new buildings in such a position as to be plainly visible and legible from the
street or road fronting the property..
I Respect y,
-. I g -mss►'
D an Nelson
Senior Plans Examiner
City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223
March 23, 2007 •
•
TIG .RD
Dennis Kwon
Marden Management
9585 SW Washington Square Rd.
Tigard, Or. 97223
RE: MAGGIE MOO'S /AUNTIE ANNES (Tenant Improvement)
Project Information
Building Permit: BUP2007 -00121 Occupancy Type: M
Tenant Name: Maggie Moo's Construction Type: II N
Address: 9469 SW Wa. Sq. Occupant Load: 31
Area: 1527Sq Ft Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
2004 edition; and the State of Oregon Fire Code (OFC) 2004 edition. The submitted plans are
approved subject to the following conditions.
1) Please provide engineered design for all soffit, coved, and acoustical tile ceilings,
taking in to consideration the up to 17 ft. interstitial space between the ceiling tile
and the roof.
Design of store front and all steel stud framing showing attachment to structure.
Certificate of Occupancy: No building or structure shall be used or occupied until the Building
Official has issued a certificate of occupancy 109.1 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new
buildings in such a position as to be plainly visible and legible from the street or road fronting
the property.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
Tigard in tracking and processing the documents.
Respectful!
Ari , J el.
• an Nelson,
Senior Plans Examiner
g AA/LE1J To bEMIthig_
¥
Phone: 503.639.4171 • Fax: 503.684.7297 • w w .tigard - or.gov • TTY Relay: 503.684.2772