Plans FROM : ALL IANT SYSTEMS FAX NO. :5032309238 Sep. 21 2005 02:58PM P5 • A7 ee c 2 oD 5C t0 5 J q (o Ihw 5, fr ii piEL • t STRUT MIIMIE111 EQUIPMENT (1) 0" DIAMETER STEEL BOLT ELEVATION A -307 GRADE MIN. PER BRACING LOCATION (BY OTHERES) NOTE: IF L EXCEEDS 50 ROD STIFFENER TIMES THE DIAMETER ANGLE 2) 0" DIAMETER OF THE ROD. THEN A ROD TO ANGLE REDHEAD ANCHOR VERTICAL STIFFENER IS CLAMP, MIN 4" EMBEDMENT REQUIRED (3) PER ROD PER LOCATION (BY OTHERES) A5 ( • )6" DIAMETE4R STEEL AIRCRAFT EQUIPMENT CABLE, 7x19 STRAND CORE r TOP VIEW O F IS T' INTDETAIL 5 -07 o SCAL FROM : ALL IANT SYSTEMS FAX NO. :5032309239 Sep. 21 2005 02:57PM P1 ALLIANT SYSTEMS 1600 NW 167 PL. SUITE 330 Date: Sptember 21, 2005 � BEA�IERTON, OR 97006 Subject: GiGi Salon & Spa (503) 230$991 Number of pages including cover sheet 6 FAX (503) 230 - 9238? ft c /T 1 2005 D U I � DI i vG 0 S R0 /Oiv To: City of Tigard From: Megan Friedow, Designer Attn: Val Phone Number: , (503) 639 -4171 _ _ Phone Number: 503.619 -4028 Fax Number: £503) 5Q8 -1960 Fax Number: 503.230 -9238 Remarks: Val - Per our conversation in regards to GIGi Salon & Spa- please find the following : 1) Cut sheets for the total Weight of FCU -1 including all accessories as follows: a. Base Unit : 138.9 lbs b. Coil 1: 87.8 lbs c. Mixing box : 72 lbs d. Electric Heater: 16 lbs Total Weight: 314.7 lbs (therefore, additional structural not required) 2) Seismic restraint detail for FCU -1 3) Confirmation of space above ceiling at FCU -1 location to be 7'10" • (floor to bottom of deck height at 17'10" wl 10' ceiling in kitchen/laundry area) 4) Duct inatallationlhanging In compliance to SMACNA standards as specified In note #4 of original general notes on plans, which roads "DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE OREGON MECHANICAL SPECIALTY CODE (IMC) AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM." (Due to duct size on this job, additional seismic/structural not required). If you need additional information, please give mo a call. My cell phone number is (971)563 -3371. Thank you, Megan Friedow FROM :ALLIANT SYSTEMS FAX NO. :5032309238 Sep. 21 2005 02:58PM P6 I SN I t#0141 ■ HVAC GENERML NOV STATE OF OREGON • 1. THE HVAC SYSTEMS FOR THIS PROJECT ARE BASED ON THE FOLLOWING CRITERIA: ROOF 'U' VALUE (BTUH/S.F'F) =0.05 (OREGON ENERGY CODE PRESCRIPTIVE - R -19 INSULATION) WALL 'U' VALUE (BTUH/S.F'F) =0.13 (OREGON ENERGY CODE PRESCRIPTIVE • R -11 INSULATION) FLOOR "U" VALUE (BTUH/S.f'F) -N /A GLASS 'U' VALUE (BTUH/S.F.'F) -0.54 (OREGON ENERGY CODE PRESCRIPTIVE - < 30% GLAZING FRACTION) GLASS SHADE COEFF. =0.57 (OREGON ENERGY CODE PRESCRIPTIVE - < 30% GLAZING FRACTION) UGHTING (WATTS/S.E.) • =1.2 MISC. EQUIP, (WATTS/S.F,) -111 PEOPLE DENSITY (PEOPLE/S.F.) =143 (ASHRAE - AVERAGE OFFIC -E OCCUPANCY 7 PEOPLE /1000 SF) COOLING INDOOR DESIGN TEMP ('F) =75 COOUNG OUTDOOR DESIGN TEMP (F) =90 HEATING INDOOR DESIGN TEMP (°F) -70 HEATING OUTDOOR DESIGN TEMP PF) =17 2 THESE PLANS CONTRACTOR I TO COORDINATE DO NOT OTHHER TRADES OFFSET S ANDS TO VERIFY ALL CLFARANCES MAY OE COMMENCING WORK. 3. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE MOST RECENTLY ADOPTED VERSIONS OF - - THE 2004 OREGON MECHANICAL SPECIALTY CODE (2003 IMC W/ STATE OF OREGON AMMENDMENTS) - THE 2004 STATE OF OREGON STRUCTURAL SPECIALTY CODE (2003 IBC W/ STATE Of OREGON AMMENDMENTS) - THE 2004 STATE OF OREGON ENERGY CODE - THE 2003 INTERNATIONAL. FIRE CODE AND ALL OTHER APPLICABLE LOCAL CODES, AMMENDMENTS, AND ORDINANCES 4. WITH STANDARDS. SMACNA AND AR DS EARTHQUAKE BRACE ALL DU I CTS 28' DIAAND LARGER WHICH ARE MECHANICAL A SUSPENDED MORE THAN 12' BELOW STRUCTURAL SYSTEM. 5 JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MAST1C TYPE DUCT SEALANT. 6. DUCTS SHALL BE INSULATED AS INDICATED ON PI ANS, OR AS OTHERWISE REQUIRED BY THE STATE OF OREGON ENERGY CODE DIJCT WRAP. WHERE INDICATED, SHALL BE 2.0" 0.6 LB /CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUMINUM FOIL VAPOR BARRIER. - SOUND UNING, WHERE INDICATED, SHALL BE 1' 1.5 LB /CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 4000 FPM. 7. FLEXIBLE DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2' FIBERGLASS INSULATION, AND NON - PERFORATED INTERIOR LINER WMI WIRE HELIX. PLK:I SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FUSIBLE DUCTS SHALL ONI Y RE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN I ENGTH UNI ESS NOTED OTHERWISE. 8. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1621 OF THE OR STRUCTURAL. SPECIALTY CODE BBC) 9. PROVIDE FIRE DAMPERS AND /OR FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716 OF 111E. INSTRUCTIONS, O HE TERMS SPECIALTY FLTHEEIRLISTINGS, FIRE DAMPERS AND ACCORDANCE F WITH THE REQUIREMENTS REMENTS OF THE BUILDING, MECHANICAI, AND FIRE CODES AND ORDINANCES 10. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIE STOPPED WITH USTEP MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL 11. PROVIDE RETURN DUCT SMOKE DETECTOR CONFIGURED TO PROVIDE AUTOMATIC SHUT DOWN OF ALL HEATING, COOLING, OR SPECIALTY CODE (IMC) POWER WIRING AND INTERLOCK WIRING WITH THE BUILDI G FIRE 606 A ALARM SYSTEM SHALL RE BY THE ELECTRICAL ELECTRICAL CONTRACTOR 12. DRAWL GUSP VALVES AND PPANELS SHALL SHALL BE PROVIDED D BY THE I CONTRACTOR AND INSTALLED BY THE GENERAL CONTRACTOR. 13 ALL MOTOR STARTERS NOT USIED AS BEING PROVIDED BY MECHANICAL CONTRACTOR (MC) IN THE 11VAC EQUIPMENT SCI'IEDULES ARE TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL CONTRACTOR (EC). UNLESS NOTED OTHERWISE, OR REQUIRED BY EQUIPMENT MANUFACTURER, SMALLERAND MOTOR STARTER W/ FU.SF)TDISCON ECTS FOR EC SWITCH/DISCONNECT EQUIPMENT 3/4 HP AND ABOVE. 1/2 HP AND FROM : ALL IANT SYSTEMS FAX NO. :5032309238 Sep. 21 2005 02:57PM P2 0101 September 08, 2005 Unit Dimensions - BCXC Blower Coll Air Handler Item: Al Qty: l Tag(s): BCXC -1 466 Sp4 NOTE: -- = AIR FLOW • - - • -- - -• - 38 °- - - -- -- - F 34° • • • w 3 7/ F22 HANGER ROD KNOCKOUTS C. + 1 ILTER ACCESS 1 t 1 "'" ' o d r i . . _ I I I I CO MOTOR ACCESS .--11.- 22 1/8" — I ACC P I PANEL I I 4 I I I 9 - - - -o o LEFT VIEW I 1 IL s - - � WEIGHT ' BASE UNIT 138.9 TOP VIEW COIL. #1 l 97.8 COIL #2 1 CONtROL BOX 18 PROVIDED WITH 7/8" [22mm] KNOCKOUTS _ . - -- FOR FIELD WIRING. FILTER ACCESS\ CONTROL BOX \ 133/4 "•" 12112" - j I ' 1 I 13 1 12" + MOTOR ACCESS COIL PANF.I ACCESS ; \ 201/A• 1 I - / I I PANEL i I` I I I I i FRONT VIEW RIGHT VIEW FLO = Furnished by Trans / Installed by Others Trans Equipment Submittal _ FRO4 : ALL I ANT SYSTEMS FAX NO. : 5032309238 Sep. 21 2005 02 : 57PM P3 ,-; mbar 08 200 GIG! _....._______......--.....--...-- Accessory - BCXC Brower Coll Air Handler Combination angle filter mixing box • Item: Al Qty: 1 Tag(s): BCXC-1 G • cp40 .... -..'• '- ---.... ' ..„.. 31 ii0^ .•---...... , ,---- .- .....--- - . .. ............. ... <, ,e.. ,..::::::... . ... '''''''''- hi ...'n 144111114141111 ■,,,,,.....,.„,/,■ 1 ! I . I i ..'".. I, ! ..-' -. ...• ' ..., [WEIGHTFib ..1 31 1 v , - .••• ' 2 - 9 ii2," • . ,.- 72 : 1* , ..... ..... - .-- ' .."*... ... r" 49 1/13" _...- IS01 VIEW ..„.,.- r - —12 3W .--- t 4 1/4 AIR FLOW • I i i .. —, ..--i— _____F__ • I I 4114 ° ACCESS PANEL i if --------- --_ i • i ------..... FILTER ---- • 22 .' -------- i „..-- , ----- .10 AIR FLOW 12 3/4 lii ' ---- F1L M --- R --- ; --- - 1 — .--- --- I - • : - 1 L i ! i 1 1- 4 1. FRONT SIDE VIEW Fum/sh by Tran /fnVelled by Others Trans EquipMent Submittal FROM : ALL I ANT SYSTEMS FAX NO. :5O3239238 Sep. 21 2005 02:58PM P4 Gial September 08, 2005 (I .. Accessory - BCXCilicwer Coil Alr Handier Right hand electric heater !tern: Al Qty: 1 Tag(s): BCXC-1 6:i i 1/4■0/ - -- CONTROL PANEL DOOR. 7/8J ELECTRICAL WEIGHT lb * _ ... 1/4... • AIR Fl OW . '--.. 1/2•:' --..... • -.. Ot°1/' ."'•.:::::•.::, -.... '', - •.. '............... ..,. 15/0' ..4.,...... ,-... . .'"',„....... • *-.......... ...., 13 /2" ,- ... 4. 3 0 ..„ . n. .... .,. ,...... '..., \ .... ..... „. .. . . .. -......., .. ... I , I ' ..,... 1 ' I ■..,, ''... .,„ .. l: 1t° 1 ;. .. • .. ...., ''-•,.., . , i2 . . ...... • . .. ... .., r ., . ".- ..,... • .. ,.., ..... , ..,. ' -,. .... . 1 " .. ,... .. . .... . . . 1) . I • .. ........, .,., IS01 VIEW •••• . ...... •-•• •••••1 1. CONTROL PANEL DOOR IS HINGED AT SIDE. ALLOW FOR CLEARANCE. • FL!) = Furnished by Trans / Installed by Others Trans Equipment Submittal ........----