Correspondence City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 October 19, 2007 UI • RE: FIRE ALARM SYSTEM t j ' ' Project Information Building Permit: BUP2007 -00522 Construction Type: 2 -B Tenant Name: Dick's Sporting Goods Occupancy Type: M Address: 9402 SW Washington Square Required: Yes The plan review was performed under the State of Oregon Structural Specialty Code (OSSC), 2007 edition the Oregon Fire Code 2007 edition and 2002 edition of NFPA 72. The submitted plans are approved subject to the following. General Requirements A separate low- voltage electrical permit is required for installation and inspection of alarm wiring. A completed inspection and testing form is required at the time of final inspection containing the information as outlined in NFPA section 10.6.2.3. TESTING — NFPA 72 Chapter 10, OFC 901.2.1, 901.5, 903.5 1. Upon completion of the installation, a satisfactory test of the entire system shall be made in the presence of the building inspector. All functions of the system or alteration shall be tested. 2. A record of completion in accordance with NFPD 72 verifying that the system has been installed in accordance with the approved plans and specifications shall be provided. 3. The permittee shall provide written certification to the Fire Chief that the system has been installed in accordance with the approved plans and specifications. A copy of the completed form shall be maintained on the premises and made available to the Fire Chief. VISUAL ALARMS — NFPA 72 - 5.14.5, 7.5.4, OSSC chapter 9 & 11 4. When required; Visual alarms shall be located not less than 80 inches and not more than 96 inches above floor level. When a low ceiling exists, the visual alarm shall be mounted within the dimensions stated above and at least 6 inches below the ceiling. No place in a room shall be more than 50 feet from a visual signal. In corridors spacing • between devices shall be no more than 100 Ft. and no more than 15 Ft. from the end. MANUAL ALARM - 1109.2.3.5, 1109.2.3.6 OSSC Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 5. Manual Fire Alarm activation devices when installed shall be mounted in the following reach ranges: • Forward Reach -15 inches to 48 inches above the floor. • Side Reach — 9 inches to 54 inches above the floor. ALARM SIGNALS — OFC 903.4 6. Alarm, supervisory and trouble signals shall be distinctly different and shall be automatically transmitted to an approved central station, remote supervising station or proprietary supervising station as defined in NFPA 72 or, when approved by the fire code official, shall sound an audible signal at a constantly attended location. 7. Duct smoke detectors shall be connected to the building's fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open -area detection. Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Dan Nelson, Senior Plans Examiner 1 PO n7-6o5,2,_ Fire Alarm Submittal WED OCT 9 / III / CITYOF rIGA D BUVLO1NGDIUISIO" Prepared for Dick's Sporting Goods Washington Square Mall Tigard, OR Submitted By ADT Tyco Fire & Security 2815 Sw 153Rd Dr Beaverton, OR 97006 (503) 469 -7100 Prepared By ADT Tyco Fire & Security National Accounts Group 120 West Park Drive Birmingham, AL 35211 Billy Sanders Phone (205)- 940 -7348 FAX (205) - 942 -4943 NICET SET 101167 09/20/07 �.<<G��N Ky Ro ssi G IBBENS DRAKE SCOTT, INC d • r 9 E. 63rd STREET, SUITE 100 - .� RAYTOWNM MISSOURI 64133 >, ✓ CREGGN ? Zl 0 1. 1, -7 9 3 7 ` • ENGINEERING Oh. LEE S ' X o g 7w Fire Marshal Inquiry Sheet Customer Dick's Sporting Goods 342 Fire Planner Billy Sanders Date Called c o AHJ's Name s7. co E Phone # 51 NFPA 72 Eg NEC ❑ ADA / Handicapped Dept name ❑ Life Safety 101 ❑ BOCA Fire & Building ❑ UBC /UFC /UMC a1 Address ❑ Southern Building ❑ South Florida ❑ Standard Flre & Bldg. j City,St Zip ❑ International ❑ Other Is combination Panel Acceptable 10 Yes O Separate Panel 0 Addressable tn E' Are there requirements for Class "A" O No 0 Both 0 Initiating 0 Indicating a) E Smoke Detector Requirements O None 0 At Panel 0 Full Smoke 0 Selected areas CD 'E Pull Station Requirements 10 None 0 At Panel 0 All Exits 43 -48" AFF 0 Front Door Q LL Annunciator Type I O None 0 LCD 0 LED 0 Special Requirement I Annunciator / Keypad Location I O Front Door 0 Attended Location 0 SprInkler Riser 0 Special Requirement I ` Monitoring of Duct Detectors I O None 0 Supervisory 0 Alarm 0 ' Mounting location I O Return duct only 0 Supply Duct Only 0 Supply and Return I O Remote Test Switches I O None 0 Below HVAC Unit 0 At Fire Panel LI Duct Detectors Powered By JO HVAC Unit 0 By Fire Panel CI HVAC Shutdown Control I O None 0 Unit Only 0 All Units Ducts only 0 All Units Any Alarm Elevator Recall I O None 0 Passanger Only N O Freight only 0 All Elevators C Notification Required I O None O 0 Full Notification 0 One Inside co Horn Strobes or Voice Evacuation I O Horn Strobes 0 Voice Evacuation r, Horn Strobe Required Outside I O None 0 Sprinkler Connectior 0 Front of Bldg. O Z Can Horn Strobes Be Ceiling Mounted I ® No 0 Ceiling Mount is OK Type of Monitoring I ® Remote Station 0 Central Station 0 Direct Connect I O • E Other Requirements I ❑ Kelton ❑Reverse Polarity ❑ UL Certificate Required I 0 Monitoring Location I O Aurora 0 Other Specify ADT c Is a separate permit required JO No 0 Yes Cost I E Can Work Begin Before Permit Is Issued I O No 0 Yes Cl. Is Knox Box Required I ® No 0 Yes Order from Fire Dept and Locate per Fire Dept Instructions. I Submittals Required O No 0 Yes 0 E Number Of Sets 2 xi Turn around time Days Weeks CO I . Stamp Required O No 0 Engineers 0 California C - 10 0 NICET c ar E E o 0 System Outline Location Dick's Sporting Goods 342 Washington Square Mall Tigard, OR II. Codes A. 2002 NFPA 72 Chapters 1 -10 as Applicable(Remote Station) B. 2002 NEC Articles 250, 725, 760 C. Local, City, State III. Control A. 1 Unimode 2000DLS Fire Alarm Control B. 2 AL1002UL -ADA -J ADA Power Booster 10A @24VDC IV. Fire Alarm Initiating Devices A. 9 BG -12LX Manual Pull Station Addressable B. 11 SD355 Smoke Detector Photo C. 2 Water Flow Connection Only, Provided by Others D. 2 Tamper Switch Connection Only, Provided by Others E. 10 Duct Detector Connection Only, Provided by Others F. 6 H355R Heat Detector Rate of Rise V. Fire Alarm Indicating Devices A. 1 LCD -80F Annunciator LCD B. 51 PC2W -115 Ceiling Horn strobe white 24VDC 115CD C. 21 PC2W -75 Ceiling Horn strobe white 24VDC 75CD D. 1 P2W -75 Wall Horn strobe white 24VDC 75CD E. 14 P2W -30 Wall Horn strobe white 24VDC 30CD F. 1 SW -75 Wall Strobe white 24VDC 75CD G. 16 SW -30 Wall Strobe white 24VDC 30CD H. 2 P2W -110 Wall Horn strobe white 24VDC 110CD VI. Zones All devices are addressable with there own adddress 1 -159 detector addresses 1 -159 module addresses SLC Loop is style 4 VII. Wiring All Circuits and Wiring Shall be "Power Limited" SLC Circuits Shall be 16/2 Sheilded U.L. FPLP Cable Initiating Zones Shall be 18/2 or 18/4 U.L. FPLP Cable Indicating Circuits Shall be 14/2 U.L. FPLP Cable System Ground Shall be 14 THWN Green Conductor Under Ground and Outside Wire shall be 14 THWN in Approved Raceway VIII. Listings A. All Equipment Shall Be U.L. Listed and Compatible IX. Power Supply A. Primary - 110 VAC Dedicated 20 Amp Circuit B. Secondary - 12 Amp Hour Battery X. Alarm Supervision A. Human B. Remote Station Installing Branch /Contractor ADT Fire & Security ADT Tyco Fire & Security 14200 E Exposition Blvd. 2815 Sw 153Rd Dr Aurora, CO 80012 Beaverton, OR 97006 (503) 469-7100 S994 -183 UUFX