Correspondence . • 4
City of Tigard, Oregon • 1 3125 SW Hall Blvd. • Tigard, OR 97223
•
� g
yf g g
UI
January 10, 2007 '-
r i
r
A &F Design
Richard Metarsky
4055 International Plaza #510
Fort Worth, TX 76109
RE: GAMESTOP — REVIEW #1
Project Information
Building Permit: BUP2006 -00580 Construction Type: II -B
Tenant Name: Gamestop Occupancy Type: M
Address: 9414 Washington Sq Occupant Load: 41
Area: 1,424 sq ft Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition
and 2004 Oregon Fire Code as amended by TVF&R.
Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work
proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances,
rules and regulations (OSSC 106.1.1). The following information is required in order to complete the review.
FIRE LIFE AND SAFETY / GENERAL
1. Provide construction information for interior wall design, connections to floor, roof etc., gage of metal
studs used and all bracing information with connection details showing walls meet chapter 16 OSSC.
OSSC 106
2. Provide engineered design on ceiling, soffit and storefront provide construction information with
connection details showing components meet chapter 16 and ASCE 7 -02, or if using a tested and listed
system provide framing and construction details along with listing and installation information.
OSSC sec.106
NOT PART OF THIS REVIEW:
*Mechanical (HVAC) *Pluming *Fire sprinkler *Electrical *Fire alarm *Low voltage
When submitting revised drawings or additional information, please attach a copy of the enclosed City of
Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing
the documents.
Respectfully,
Val Henzel, Senior Plans Examiner
Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772
City of Tigard, Oregon • 13125 SW Ha11 Blvd. • Tigard, OR 97223
I RI
February 5, 2007
4TIci*R o
A&E Design
Richard Metarsky
4055 International Plaza #510
Fort Worth, TX 76109
RE: GAMESTOP
Project Information
Building Permit: BUP2006 -00580 Construction Type: II -B
Tenant Name: Gamestop Occupancy Type: M
Address: 9414 Washington Sq Occupant Load: 41
Area: 1,424 sq ft Stories: 1
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition
and 2004 Oregon Fire Code as amended by TVF &R. The submitted plans are approved subject to the
following conditions.
1. The main exterior door or doors are permitted to be equipped with key - operated locking devices from the
egress side provided:
1. The locking device is readily distinguishable as locked,
2. A readily visible durable sign is posted on the egress side on or adjacent to the door
stating. THIS DOOR TO UNLOCKED WHEN BUILDING IS OCCUPIED.
The sign shall be in letters 1 inch (25 mm) high on a contrasting background. Sec. 1008.1.8.3
2. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort.
Sec. 1008.1.8
3. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of
egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the
path of egress travel is not immediately visible to the occupants. Sec. 1011.1
4. Exit signs shall be illuminated at all times and shall be provided with a second source of power that will
provide 1 1/2 hours of illumination in case of primary power loss. Sec. 1006.3 FYI Additional exit signs
may be required by the city field inspector to clearly indicate the path of egress.
5. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level
anytime the building is occupied. The means of egress illumination shall be provided with a second
source of power in case of primary power loss. Sec. 1006.2
6. Provide 2 -A rated fire extinguisher in new store and storage area. The extinguisher shall be located so that
no usable space has a distance greater than 75 feet to the extinguisher. OFC 906.3
Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard - or.gov • TTY Relay: 503.684.2772
7. Accessible checkout aisles shall be on an accessible route and at least 36 inches wide. Counters in
accessible checkout aisles shall be not more than 38 inches (965 mm) high and the top of the raised edge of
the counter shall not exceed 40 inches (1016 mm) in height above the finished floor. Accessible checkout
aisles shall be identified by the international symbol of access. Sec. 1109.19, 1109.23.3
8. Doors to unisex toilet rooms shall be securable from within the room and be provided with a privacy lock
and an "occupied" indicator. 1109.10.12.4 OSSC
10. Safety glazing including but not limited to the following locations: Each unit of glazing shall be
permanently identified by the manufacturer. Sec. 2406. Some of these locations are as follows:
a. Glazing in ingress and means of egress doors.
b. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge
is within a 24" arc of the door in a closed position and whose bottom edge is less than 60" above
the floor or walking surface except when there is an intervening wall or other permanent barrier
between the door and the glazing.
c. Glazing in swinging doors except jalousies (see Section 2406.3.1).
d. Glazing in unframed swinging doors.
11. American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer,
Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the
structure. The City of Tigard reviews the plans and inspects the structure only for compliance with
Chapter 11 of the OSSC, which may not include all of the requirements of the ADA.
NOT PART OF THIS REVIEW:
* Electrical * Fire Sprinklers or Alarms * Mechanical System * Plumbing
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on
the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of
construction. 106.3.1 OSSC
Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official has
issued a certificate of occupancy 110.1 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a
position as to be plainly visible and legible from the street or road fronting the property.
When submitting revised drawings or additional information, please attach a copy of the enclosed City of
Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing
the documents.
Respec. ; ,
• al en el ,
Senior Plans Examiner