Loading...
Specifications 7 blot .t� :5-o Bulletin 121 Rev.l MENIERMEININEMMIERNME W , :; ® ® Model G4 Concealed zff Automatic Sprinkler r The Concealer , A Concealed Sprinkler ' . . . • • . ! With X" (13mm) or , t ° 4 :, ,,: ' 1 X " (38mm) Adjustment , ; r j : ' __ ' ` Features :__ . m M. . . 1. Push- on/Thread -off cover plate assembly : ^.; ' . - attachment with 1/2" (13mm) adjustment. Does not require clips or springs. t- .Yf`rz_.. °. .. ,.. , 2. 1'/2' (38mm) Total adjustment provided by .. `''' " adjustable inlet versions. ,'' :. , 3. Adjustable inlet version available with either , --- - V 1" NPT ale or female threads eliminating ' � , - , ; costly reducing coupling. 4. Smooth aesthetic ceiling profile. - - `�` y 5. Available in white or other color painted or The Concealed is designed for use where aesthetic ap brass, chrome, or black plated finishes. pearance is important. Offices, hospitals, motels and res- 6. Ordinary and intermediate temperature taurants are but a few of the applications where it can be ratings. used. It is available in different orifice sizes allowing the de- g signer to optimize system performance, thereby achieving a 7. Multiple orifices for design flexibility. most efficient installation. The Concealer can eliminate the need for precise cutting of drop nipples. The Push -on /Thread -off cover plate assem- 1 bly can be adjusted without tools so it mates accurately with Approvals & Listings the ceiling. The fire protection system need not be shut 1. Underwriters Laboratories Inc. (UL) down to adjust or remove the cover plate assembly. 2. Underwriters Laboratories of Canada. (ULC) Product Description 3. N.Y.C. BS&A No. 587- 75 -SA. The Reliable Model G4 Concealer uses the proven Note: Approvals are for light and ordinary hazard, except for Model G fusible element in a standard style sprinkler frame small orifice sprinklers which are limited to light hazard with a drop -down deflector. This assembly is recessed into occupancies. The cup and skirt are fabricated from plated the ceiling and concealed by a flat cover plate. The steel and are intended for interior non corrosive applications. Push- on/Thread -off cover plate and sprinkler cup assem- blies are held tight by a flexible tooth engagement to the U.S. Patent No. 4,880,063. threaded cup. This threaded engagement provides '/z" (13mm) of cover adjustment. The fiat cover plate is attached Application to the skirt using an ordinary temperature classification sol- The Reliable Model G4 .. der. This results in a strong cover plate assembly with an or- dinary temperature rating, and an intermediate temperature Concealer is the most versatile sprinkler which can be installed in 150 °F (66 °C) environ- concealed sprinkler available. It ments. When the ceiling temperature rises, the solder hold - provides the best form of fire pro- ing the cover plate to the skirt melts, the fiat cover plate tection while offering an attractive -- released thus exposing the sprinkler inside to the rising am- appearance and Yz" (13mm) of bient temperature. cover adjustment for ease of instal- 1 11 . 11 i The subsequent fusing of the sprinkler element opens the r s . The adjustable 1" NPT inlet waterway and causes the deflector to drop into position to versions have 1/ (38mm) of total distribute the discharging water. Any secure engagement of adjustment and also eliminates the need for a reducing cou- the threads between the cover plate and cup will assure that piing. The small diameter Push - on/Thread -off cover plate the drop-down deflector is properly located below the cell- ' assembly is easily attached and blends into the ceiling, con- ing when a sprinkler operates. cealing the most dependable fire protection available, an automatic sprinkler system. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Installation hex flats. After the ceiling has been installed with holes for the Do not install The Concealer in ceilings which have positive sprinkler, each telescoping inlet section is to be adjusted with the p resure in the space in the space abate. G4 Wrench. Install the push- on/thread -off cover plate assembly After a 24 inch diameter hole is cut in the ceiling, the sprinkler over the sprinkler by holding and pressing it straight up into the is to be installed with the Model G4 Wrench. The wrench has cup. Final adjustment of each cover assembly is made by hand drive tangs which insert into cup slots. When installing a sprin- turning it clockwise until it is tight against the ceiling. kler the wrench is first positioned into the sprinkler /cup assembly Maintenance until the wrench tangs engage drive slots in the top of the cup The Model G4 Concealer should be inspected quarterly and (there are two sets of mating drive slots in the cup). The sprinkler the sprinkler system maintained in accordance with NFPA 25. is then tightened into the pipe fitting. When inserting or removing Do not clean sprinklers with soap and water, ammonia or any the wrench from the sprinkler /cup assembly care should be other cleaning fluids. Remove any sprinkler that has been taken to prevent damage to the sprinkler. DO NOT WRENCH painted (other than factory applied) or damaged in any way. A ON ANY OTHER PART OF THE SPRINKLER CUP ASSEMBLY. stock of spare sprinklers should be maintained to all quick re- The adjustable inlet versions are similar to the standard Model placement of damaged or operated sprinklers. Prior to instate- G4 except that an addition 1" (25rrmm) of adjustment is provided Win, sprinklers should be maintained in the original cartons and by means of a telescoping inlet section that threads in or out of a ka I to rnnim¢e the potential for damage to sprinklers that stationary coupling reducer (either 1 male or 1 female) as shown �dg improper operation or non-operation. in Fig. 2 or Fig. 3. These sprinklers must be installed before the Cover Plate Finishes lt) ceiling is in place, by wrenching on only the coupling reducer Ordering Information 1. Sprinkler Model Standard Finishes Temperature Ratings 2. Temperature Rating Bronze P 9 3. Nominal Orifice Chrome Plated max Ambient 4. Flat Cover Plate Finish White Classification Sprinkler over Plata Temp. 5. Inlet Type N ote: U nless otherwise Special Application Ordinary 135 °F /57 °C 135 °F /57 °C 100 °F /38 °C specified, the 165°F (74°C) Finishes Ordinary 165 °F /74 °C 135 °F /57 °C 100 °F /38 °C sprinkler will be provided with Black Plated Ordinary 165 °F /74 °C 165 °F /74`C 100 °F /38 °C the 165 °F (74°C) cover. Bright Brass Intermediate 212 °F /100 ° C 165 °F /74 °C 150 °F /66 °C Off White Installation Data Black Paint Nominal Sprinkler m Other colors and finishes are Sprinkler Total Nominal K F ctnr Thread Approvals identification available Consult factory for Inlet Adjustment Orifice US Metric Number dew (SINI Non - Adjustable X"(13mm) y' (15mm) 5.6 80 y2 " NPT (R'h) 1,2,3 R2115 Note: Paint or any other Non - Adjustable y" (13mm) ;(B (11rnm) 42 60 X" NFT (R1/2) 1,2,3 R2113 coatings applied over the Non - Adjustable ^(13mm) % "(1arim) 2.8 40 y "NPT(RIM 1,2,3 R2111 factory finish will void all y Adjustable 1y" (38mm) �(15nun) 5.6 80 1 "NPT Male «Female 1,2,3 R2118 approvals and warranties. Adjustat ei 1y "(38mm) ;(a "( 42 60 1" NPT Male or Female 1,2,3 R2113 Installation Wrench A d j u s t a b l e 1 " (38mm) 3e"( 1 28 40 1" NPT Male — 1,2,3 R2112 Model G4 Sprinkler Wrench i I--4,7-- I I I� r. ,r tee. - + — --I -� c �� m I (---01--- l_ L IiLI. ,1 1 '� r o� r IOW .wu 1 '„� f i b - t l °sue iiiiiiiiii LI 0.17 III 2/ i , h� ,' imJ ,. Fig. 1 - ;z" (Ry NPT Non- Adjustable Inlet Fig. 2 - 1" NPT Male- Adjustable Inlet Fig. 3 - 1" NPT Female - Adjustable Inlet The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries Manufactured by +-:r i;', , =d;: , The Reliable Automatic Sprinkler Co., Inc. fieliable (800) 431 -1588 Sales Office (800) 848-6051 Fax (914) 668 Corporate Offices Revision lutes indicate updated or new data _ _. .. _ ... www rehabieprinkler corn Internet Address EG Prnied n usA.06°2 PM 9999970014 Bulletin 110 Rev S Model G W co Automatic Sprinklers 71 t Spray Upright, 1 - rn Spray Pendent o And Conventional Product Description The Reliable Model G Automatic Sprinkler utilizes the _ _ center strut solder in compression principle of construction. The fusible alloy is captured in the _ a cylinder of the solder capsule by a stainless steel ball. '1, ' `` '. When the fusible alloy melts, the ball moves into the U . _ cylinder allowing the cylinder to fall away from the . sprinkler. When this happens, the lever is released to - spring free from the sprinkler so that all of the operating - r. parts clear from the waterway allowing the deflector to distribute the discharging water. . • . IF - Except for the parts in the cylinder as mentioned above, the sprinkler components are made from Upright Pendent copper based alloys for maximum corrosion , protection. Lead plated, wax coated or wax over lead = plated sprinklers are available for specially severe ` t environments. Chrome plated sprinklers are available , for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by " t• markings that appear on several of the operating parts and by an identifying color that appears on the frame. ' Sprinkler Types Standard Upright - This deflector configuration is Small Orifice Upright Conventional normally used with exposed piping installations. Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. Standard Pendent - This deflector configuration is Application and Installation normally used where the space above the piping is Standard sprinklers are used in fixed fire protection I limited or where a concealed piping installation is systems: Wet, Dry, Deluge or Preaction. Care must be employed. The discharge characteristics of the exercised that the orifice sizes, temperature ratings, standard pendent are virtually identical to the deflector styles and sprinkler spacings are in standard upright as described above. accordance with the latest published standards of the National Fire Protection Association or the approving Large and Small Orifice —By varying the orifice size, authority having jurisdiction. a large or small orifice sprinkler is created that will The sprinklers must be installed with the Reliable distribute as much as 40% more water or 65% less Model D Sprinkler Wrench. Any other type of wrench water than the normal 1/2" (15mm) orifice sprinkler. may damage the sprinkler. The approvals or listings of Reliable Automatic Conventional —This deflector configuration is used Sprinklers by major approving organizations are primarily in those countries where the LPC installation shown in the tabulated list provided on the back of this rules have precedence. The sprinkler is designed to bulletin. distribute a portion of its water discharge upward against the ceiling with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, Patent No. 4,440,234 ordinary and extra -high hazard installations. The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Technical Data "K" Factor Sprinkler Identification Sprinkler Number (SIN) Sprinkler Type US Metric Height Approvals SSU SSP Standard - Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position X" (15 mm) Standard Orifice with y2" NPT (Ry) Thread 5 62 81 0 2' /e" (73 mm) 1, 2, 3, 4, 5, 6, 7 R1025 R1015 7 ,6 ' (1i mm) Small Orifice with }2" NPT (R%) Thread 4.24 61 0 2' /e" (73 mm) 1, 3, 7 R1023 R1013 %" (10 mm) Small Orifice with X" NPT (R}2) Thread 2 82 40 6 2' /a" (73 mm) 1, 2, 3, 7 R1021 R1011 X," (8 mm) Small Orifice with X" NPT (Ry) Thread 1 98 28 5 2' /e" (73 mm) 1, 3, 7 R1022 R1012 1 %2' (20 mm) Large Orifice with }2" NPT (R}2) Thread 7 96 114.7 2' /e" (73 mm) 1, 2, 3, 7 R1026 R1016 1 %Z' (20 mm) Large Orifice with 3 ," NPT (R %)Thread 8 20 118 2 2 1 %6 " (75 mm) 1, 2, 3, 7 R1027 R1017 20 mm XHH with 20 mm Thread 8 20 118 2 75 4 mm 4, 5, 6 R1027 R1017 10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 4, 5, 6 R1024 R1014 Conventional — Installed in Upright or Pendent Position 10mm XLH with 10mm Thread 4 10 59 1 73 mm 5 R1074 15mm Standard Orifice with (R%) Thread 5 62 81.0 73 mm 4, 5, 6 R1075 20mm XHH with (R %) Thread 8.20 118 2 75 4 mm 4, 5 R1077 Temperature Ratings Maintenance Maximum Model G Sprinklers should be inspected quarterly and the Sprinkler Ambient sprinkler system maintained in accordance with NFPA 25. Do Rating Temperature Frame t1) not clean sprinklers with soap and water, ammonia or any other Classification °F °C °F °C Color cleaning fluids. Remove any sprinkler that has been painted Ordinary 135 57 100 38 Black (other than factory applied) or damaged in any way. A stock of Ordinary 165 74 100 38 Uncolored spare sprinklers should be maintained to allow quick replace - Intermediate 212 100 150 66 White ment of damaged or operated sprinklers. Prior to installation, High 286 141 225 107 Blue sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to (1) Frame color does not apply to painted or plated sprinklers sprinklers that would cause improper operation or -Use sprinkler rating as identified on operating parts. non - operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation Any other type of wrench may damage the sprinkler. Finishes Standard Finishes Approval Organizations Bronze —All Temperature Ratings 1. Underwriters Laboratories, Inc. Chromq —All Temperature Ratings 2. Factory Mutual Research Corporation White l —All Temperature Ratings 3. Underwriters' Laboratories of Canada Only Frame and Deflector are Painted 4. Loss Prevention Council Special Application Finishes 5. Pleniere Assemblee Bright Brass Plated —Only frame, deflector and cap are plated. 135 °F (57 °C), 165 °F 6. VdS S BS&A No. 5 8 — g N (74 °C), 212 °F (100 °C) Temp. Rating 7. N Y.C. MEA N.Y.C. MEA 258-93-E 75—SA or Black Plated —Only frame, deflector and cap are plated All Temp Ratings Polyester Coated (2) -Only frame and deflector are coated. Lead Plated —165 °F (74 °C), 212 °F (100 °C) and 286 °F (141 °C) Temp. Ratings Ordering Information Wax- Coated (3) —165 °F (74 °C) Clear Wax, 212 °F (100 °C) Brown Wax. Specify Wax- Coated Over 1. Model G Lead Plated (3) —165 °F (74 °C) Clear Wax, 212 °F (100 °C) Brown Wax. 2. Deflector • Upright ( Other colors and finishes are available. Consult factory for details. • Pendent ( UL listed and NYC MEA Approved only • Conventional ( 212 °F (100 °C) brown wax may be used on 286 °F (141 °C) 3. Nominal Orifice sprinklers when maximum ambient temperatures do not exceed 150 °F 4. Inlet Thread (66 °C) UL Listed, FM Approved, NYC MEA 258 -93 -E. 5. Temperature Rating 6. Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries Manufactured by ENEMISBEIMEHIMMEIMIIIIIIIIMIMI The Reliable Automatic Sprinkler Co., Inc. Ut j "qf r` ® 1 � ': sender Tr 91i : F " i it ( 800 ) 431 -1588 Sales Offices i t'''' e i - + � a (800) 848 6051 Sales Fax paper i. �=' -`:.i �' ,, ' -a ti i (914) 668 3470 Corporate Offices Revision lines indicate updated or new data RESESIMEXEMEINSEE www reiiabiesprinkiercom Internet Address EG PnntedinUSA 11/04 PM 9999970005