Loading...
Plans % 24,e,W,A6- re 5 ep ?3 S d4,Ifig c,(, FIRE ALARM SUBMITTAL Washington Square Starbucks cAECEI OCR 20 1 005 CITY �F IIV I�oN c,11 DIN D Siemens Job Nu rH�er 261004 Siemens Project Manager Chuck Neely Siemens Project Engineer Ron Pulioff Date Submitted October 12, 2005 Proprietary document for approval only SIEMENS Siemens Building Technologies, Inc. 3025 S.W. Corbett Ave Portland, OR 97201 Phone: (503) 234 -9995 Fax: (503) 234 -8030 Table of Contents SIEMENS BILL OF MATERIAL & COMPONENT SPECIFICATIONS FUNCTIONAL MATRIX BATTERY CALCULATIONS 4 - VOLTAGE DROP CALCULATIONS BILL OF MATERIALS SIEMENS Washington Square Starbucks xxxxxx Fire Alarm System Item Part # Qty Mfg Description 1 FP -11 3 Siemens Fire Print Intelligent Detector 2 DB -11 3 Siemens Detector Base Standard 4 TRI -R 3 Siemens Single Input Relay Module 3 E50- 24MCW -FW 3 Wheelock Speaker /strobe, Multi- candela, White PROPRIETARY DOCUMENT FOR APPROVAL ONLY 3 10/19/2005 SIEMENS Fire Safety FP -11 FirePrintTM Detector Intelligent Fire Detector for MXL, MXL -IQ, and MXLV Control Panels ENGINEER AND ARCHITECT SPECIFICATIONS • Most Sophisticated "Detector Intelligence" available today • Multi- Criteria fire detection for the price of a photoelectric detector • FirePrint'MTechnology to discriminate between deceptive phenomena and an actual fire • Easily programmed to match specific hazard profiles from the control panel • Pre -Alarm reporting based on fire profile selected • Remote sensitivity measurement capability • System logic activation based on any of three inputs from detector (smoke, heat or neural network) • Field cleanable chamber with replaceable chamber $ , parts available • Multi -color detector status LED • Two -wire operation • Compatible with Model DPU or FPI -32 field rx programmer/tester • Supports EnviroLlNK software based automatic environmental compensation • Backward compatible with older MXL systems (Rev. 2 and above) • Optional fully programmable relay base , audible base, and duct housing • o UL Listed, ULC Listed, CSFM, FM, NYMEA UL Approved Introduction The FP - 11 Intelligent Fire Detector provides the life need for cumbersome, unreliable mechanical program - safety industry with the most highly evolved detection ming methods and reduces installation and service system available today. The FP -11 utilizes advanced costs by electronically programming and testing the detection technology that allows the detector to detector prior to installation. distinguish nonthreatening deceptive phenomena, such The FP 11 fire detector is compatible with the MXL as cigarette smoke, from actual fire hazards, while optimizing detection for the area in which it is in- family of control panels including the MXL, MXLIQ, stalled. No other detection system available today and MXLV. offers a higher level of protection or nuisance The FP -11 detector is Underwriters Laboratories and alarm immunity. The FP -11 uses state- of- the-art Underwriters Laboratories of Canada Listed. microprocessor circuitry with error check, detector self- diagnostics and supervision programs. Description The FP 11 intelligent fire detector is compatible with The FP -11 is a plug -in, two -wire, multi- sensor detector the Siemens Building Technologies, Fire Safety Divi with both photoelectric and thermal inputs and is sion, Model DPU or FPI -32 field programmer /tester, compatible with the MXL family of control panel which is a compact, portable, menu - driven accessory for electronically programming and testing detectors, systems. Each detector consists of a dust resistant, easily and reliably. The DPU or FPI -32 eliminates the field cleanable photo chamber, a solid state CATALOG NUMBER 6175 non - mechanical thermal sensor, microprocessor based evaluating this information with sophisticated electronics with a low- profile plastic cover and base. mathematical formulas, or algorithms, comparing this The FP -11 utilizes state- of- the-art ASIC and surface input to characteristics of both threatening fires and mount technology for maximum reliability. Every FP -11 deceptive phenomena that would "fool" any ordinary fire detector is shipped with a protective dust cover. detector. This technology was developed over years of The FP 11 fire detector utilizes an infrared light research and reviewing the results of over 20 years of fire test data in one of the world's most advanced fire emitting diode ( IRLED), and light sensing photodiode. Under research centers. The results of this research are the nder normal conditions, light transmitted by the LED mathematical models that form the algorithms used in is directed away from the photodiode and scattered FirePrint. No other fire detector has this level of through the smoke chamber in a controlled pattern. intelligence or this amount of research and develop - The smoke chamber is designed to manage light ment supporting it's design. dissipation and extraneous reflections from dust particles or other non -smoke airborne contaminants in The microprocessor's software can identify and such a way as to maintain stable, consistent detector disregard false input caused by radio frequency (RFI) operation. When smoke enters the detector chamber, and electromagnetic (EMI) interference, and validates light emitted from the IRLED is scattered by the all trouble conditions before annunciating or reporting smoke particles and is received by the photodiode. to the control panel. The FP -11 detector's microproces- The sor uses an integral EEPROM to store the detector's he FP 11 also utilizes a modern, accurate, shock- resistant thermistor to sense temperature changes. address and other critical operating parameters which include the assigned program values for alarm and The "on- board" FirePrint technology allows the detector to gather smoke and thermal data, and to trouble thresholds. Communications within the analyze this information in the detector's "neural detector itself and between the FP -11 and the control network:' By comparing data received with the panel, or with the FPI -32 field programmer /tester, are supervised and safeguarded against disruption by common characteristics of fires, or fire fingerprints, reliable, microprocessor based error checking routines. the FP -11 can compare these "Fire Prints" to those of Additionally, the microprocessor supervises all deceptive phenomena that cause other detectors to EEPROM memory locations and provides a high alarm. The advanced FirePrint technology allows the degree of EEPROM failure fault tolerance. FP -11 to accurately determine a true fire hazard from a nonthreatening deceptive phenomena WITHOUT In MXL(V) applications, the FP -11 determines its needing to use alarm delaying verification and confir- operating status to be normal, in alarm, or in trouble mation techniques, which can increase the probability depending on the difference between the alarm of losses due to fire. threshold values stored in the detector's memory and The the highest level of detector he detector's latest analog measurement. The T FP -11 provides etector intelligence ovid able today with a e of d detector/control detector then communicates changes in its status to the control panel. panel link that allows the user to program the detector for the specific hazard profile Detectors are optimized In addition, the MXL(V) control panel will sample the by selecting one of the following applications: value of the FP -11's analog signal over a period of time in order to determine if those values indicate exces- • Office /Retail sive buildup in the photo chamber; if so, the MXL(V) • Lobby will indicate that the particular detector requires • Computer Room maintenance. • Dormitory - • Healthcare The FP -11 is listed as a self- testing device. The FP -11's • Parking Garage visible light emitting diode (LED) flashes green every • Utility/Transformer Room 4 seconds to indicate it is communicating with the . • Hostile Environment control panel and that it has passed its internal self- • Precious Storage test. Should the detector sense a fault or failure within • Air Duct its systems, the LED will flash amber and the detector • Warehouse /Light Manufacturing will transmit that information to the control panel. The software does the rest; no guessing on detector A quick visual inspection is sufficient to indicate the condition of the detector at any time. If more detailed sensitivities or alarm verification; the control panel information is required, a printed report can be programs the FP -11 detector for the protected area provided from the MXL panel indicating the status without hassle and without confirmation delays. and settings assigned to each individual detector. Once optimized for the hazards in the protected area, the FP -11 provides the best detection you can buy. When the FP -11 moves to the alarm mode, it will flash Should the operator or installer forget to program the amber and transmit that information to the control detector, the FP -11 will revert to a default setting that panel. When the MXL(V) confirms the detectors allows it to operate as a standard photoelectric or condition, the panel will instruct the FP -11 to flash red photothermal detector. and to continue flashing until the system is reset at The FP 11's FirePrint technology monitors input from the control panel. At that same time, any user defined both the photo chamber and the thermal sensor, system alarm functions programmed into the system All FP -11 detectors are approved for operation within are activated. Each FP -11 detector can operate one the UL specified temperature range of 32 to 100 remote alarm indicator, one auxiliary relay, or one degrees F (0 to 38 degrees C). audible base. Detector sensitivity, calibration, and identification are Application Data ' dynamically supervised by the control panel. Detector Installation of the FP -11 series of fire detectors sensitivity and pre -alarm levels are a function of the requires a two-wire circuit of 18 AWG (minimum) application chosen at the control panel and are thermoplastic fixture wire enclosed in conduit, or 18 controlled by the panel. If an alternate, non - FirePrint AWG limited energy, shielded cable without conduit, mode is selected, then the sensitivity can be changed if permitted by local codes. Field wiring should from the control panel. conform to local and National Electric Codes and the The DPU or FPI -32 Program/Test accessory is used to control panel wiring specifications. program and verify the detector's address. The "T- tapping" is permitted only for Style 4 (Class B) technician selects the accessory's program mode to wiring. enter the desired address. The DPU or FPI -32 auto- matically sets and verifies the address and tests the FP -11 fire detectors can be applied within the maxi - detector. It also allows the user to change the device mum 30 foot center spacing (900 sq. ft. areas) as ID from that of an FP -11 to an older detector ID such as referenced in NFPA 72. This applications guideline is an ILP -1, ILPT -1, ILP -2, ID -60P or ID -60PT to allow for based on ideal conditions, specifically, smooth ceiling • easy replacement of older detectors without the need surfaces, minimal air movement, and no physical of reprogramming the control panel. obstructions between potential fire sources and the detector. Do not mount detectors in close proximity The FPI -32 operates on AC power or rechargeable to ventilation or heating and air conditioning outlets. batteries, providing flexibility and convenience in Exposed joints or beamed ceilings may also affect safe programming and testing equipment almost anywhere. spacing limitations for detectors. Should questions When in the test mode, the DPU or FPI -32 will perform arise regarding detector placement, observe NFPA a series of diagnostic tests without altering the 72 guidelines. address or other stored data, allowing technicians to determine if the detector is operating properly. Good fire protection system engineering and common sense dictate how and when fire detectors are The FP -11 fire detector may be installed on the same installed and used. Contact your local Siemens initiating circuit with IL or ID series detectors (Photo- Building Technologies, Fire Safety Division authorized electric, thermal, or ionization), MSI series manual sales outlet whenever you need assistance applying stations, TRI series interfaces, ICP output control FirePrint in unusual applications. Be sure to follow devices, or CZM series of addressable, conventional NFPA guidelines, UUULC approved installation zone modules. instructions, which are included with every detector, All FP -11 detectors can be cleaned in the field, when and local codes as for all fire protection equipment. required, by simply removing the detector cover and unsnapping the photo chamber. There is also the Dimensions option of cleaning the interior of the detector with a clean, soft cloth or brush, or replacing the labyrinth and 6' Diameter Base bug screen included in the detector maintenance kit, model DMK -11. ,_,�� The FP -11 uses the low profile surface mounting base, �� • model DB -11. This base mounts on a 4 -inch octagon, T -0 11 1 11111111 ,„.„" w square, or a single gang electrical box. The base Z3' utilizes screw clamp contacts for electrical connections Overall � , Hei , r and self- wiping contacts for increased reliability. The base can be used with the optional LK 11 detector 4 -�`ry locking kit which contains 50 detector locks and an ���_ installation tool, to prevent unauthorized removal of , the detector head. The DB -11 base has integral decora- tive plugs to cover the outer mounting screw holes. The FP -11 is electrically compatible with existing MXL detector accessories including relays, remote lamps, duct housings, and audible bases. With duct housings, a base adapter and new detector housing cover are required (order AD-11 UK upgrade kit). To use existing DB -3S base or audible base, the FP -11 requires a DB- ADPT base adapter. Technical Specifications Current Requirements: Normal 750 pa Alarm 750 pa Operating Temperature: +32 °F (0 °C) to 100 °F (38 °C) per UL 268/268A Humidity: 0 -93% Relative Humidity Non - Condensing Ordering Information Part Model Description Number FP-11 Addressable FirePrint Fire Detector 500-095112 DB -11 Detector Mounting Base for Series 11 500-094151 DB -11E Detector Base (Small) 500- 094151E AD-11P Air Duct Housing for Series 11 500- 095656 AD -11XPR Air Duct Housing w /Relay for Series 11 500-096062 Intelligent Detector ADBX -11 Audible Base 500- 096181 • DB-X11RS Relay Base for Series 11 Intelligent Detectors 500- 096125 RU -1 Remote (red) alarm indicator- 4' octagon box mount 500- 390673 RU -2 Remote (red) alarm indicator- single gang box mount 500- 390674 LK -11 Base Locking Kit for Series 11 detectors 500 -695350 DMK -11 Series 11 Maint Kit (replacement labyrinth and bug 500 - 695338 bug screen) AD -11UK Air Duct Housing Cover /Adapter Kit 500- 695967 DB -ADPT Base Adapter to DB -3S Base 500- 094187 In Canada Order. FP-11C Addressable FirePrint Are Detector(ULC) 500- 095112C DB -11C Detector Mounting Base for Series 11 (ULC) 500- 095687 AD -11PC Air Duct Housing (ULC) 500- 095984 DB -X11 RSC Relay Base for Series 11 Intelligent Detectors IULCI 500- 096125C ADBX -11 C Audible Base for Series 11 Intelligent Detector (ULC) 500- 096181C Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 6/03 Brampton, Ontario Siemens Building Technologies Tel: (973) 593 -2600 10M Canada L6T 5E4 g g FAX: (973) 593 -6670 SFS-IG Tel: (905) 799 -9937 June 2003 Fire Safety Website: www.sbt.siemens.com /fis Printed in U.S.A. FAX: (905) 799 -9858 summoes sheet dated 7do2 SIEMENS Fire Safety TRI Series - Intelligent Initiating Devices Interface Modules for MXL Fire Detection Panels TRI- S,TRI- D,TRI -R ENGINEER AND ARCHITECT SPECIFICATIONS • Interfaces and Supervises Normally Open Contacts • Integral SPDT Relay (up to 4 amps) on TRI -R Model • Dual Input on TRI -D Model • Multi -color L.E.D. indicates status (green, amber, red) • Easy front access to programming port and wiring terminals R , • Mounts in 4 inch square 2 deep box, or double gang box • • Dynamic Supervision DISCO NEC QI q • Comes with 5x5 inch faceplate DEVIC E C C �ORE P T TER, AD • Two wire operation RESS T c�R�AM NG REFER N ER T O INST 1ERMINA,S96242 INST ARE PO LIMITED • Model DPU or FPI -32 Programs and Verifies Device's Address and Tests Device's functionality _ - { • Electronic Address Programming is Easy and Dependable • ® UL Listed, ULC Listed CFSM, FM, NYMEA Approved Introduction module reports the contact's status to the control The TRI Series Intelligent interface modules are panel. The TRI -S model can only monitor and report the designed to provide the means of interfacing direct status of the contact, while the TRI -R incorporates an shorting devices to the MXL system's ALD loop addressable Form C relay. The TRI -R relay and contact circuit. device input are controlled at the same address. For the MXL system, the relay and input contact can be The TRI Series Intelligent interface modules provide controlled as a separate function. The relay is typically the market's most advanced method of address used where control or shunting of external equipment programming and supervision, combined with sophis- is required. ticated control panel communication. Each TRI Series interface module incorporates a microcomputer chip. The TRI -D is a dual input module and is designed to The TRI Series microcomputer chip technology and its supervise and monitor two sets of dry contacts. This sophisticated bi- directional communication capabilities interface module requires two address settings. The with the control panel, achieve the state of an "Intelli- TRI -D is ideal for monitoring a waterflow switch and its gent Device." respective valve tamper switch. The TRI has a multi -color Light Emitting Diode that Description flashes green when operating normally, amber if unit The TRI Series Intelligent interface modules are avail- able in three models. The TRI -S and TRI -R are designed to monitor a normally open dry contact. The interface CATALOG NUMBER 6179 is in trouble condition, and red to indicate a change of Mounting Data state. The TRI -D flashes twice, once for each address, Addressable interface Model TRI S, TRI D, TRI -R the TRI R red L.E.D. indicates a change of state in mounts directly into a 4 inch square 2 deep box the relay. or a double gang box (user supplied). A 5 inch square The device's microcomputer chip has the capacity of off -white faceplate is included with each TRI. storing, in memory, identification information as well as important operating status information. MOUNTING SLOTS FOR 4 INCH Siemens Building Technologies, Fire Safety Division SWITCHBOX innovative technology allows all TRI Series intelligent interface modules to be programmed by usiitg the model DPU or FPI -32 Programmer/Tester. The Pro- O grammer/Tester is a compact, portable, menu driven accessory that makes programming and testing an [ =_J I TRI- S / -D / -R interface device faster, easier and more dependable ['_] I MODULE Ufa O than previous methods. [=_7 ,, The DPU or FPI -32 eliminates the need for mechanical �� = MOUNTING Eel addressing mechanisms, such as program jumpers, HOLES FOR DIP switches or rotary dials, because the Programmer/ ii SWITCHPLATE Tester electronically sets the TRI interface's address -- — — into the interface's microcomputer chip nonvolatile 0 memory. Vibration, corrosion and other conditions that deteriorate mechanical addressing mechanisms are no longer a cause for concern. MOUNTING SLOTS The TRI Series is fitted with screw terminals for FOR DOUBLEGANG connection to an addressable circuit. SWITCHBOX The TRI Series is fully compatible on the same MXL Figure A circuit with all intelligent FP IL and ID -60 Series Mounting the TRI- S / -R / -D detectors, MSI Series addressable manual stations or any other addressable intelligent modules, such as the CZM or ICP. Electrical Ratings All TRI Series intelligent interface modules are Current Draw (Active or Standby): 1.5mA UL listed. Environmental operating conditions for all TRI Series esi Relay R 1 25s R modules are 32 °F ( °C) to 120 °F (49 °C) with a relative Resistive: 4A, 15 VAC humidity of not greater than 93% non - condensating. 4A, 30 0 VDC Inductive: 3.5A, 120 VAC (0.6P.F.) Ordering Information 3.0A, 30 VDC (0.6P.E) 2.0A, 120 VAC (0.4P.F.) . Shipping Wt. 2.OA, 120 VAC (0.35P.F.) Model Description Lb. Kg. 2.OA, 30 VDC (0.35P.F.) TRI -S Single Input 7 oz. 2 TRI -R Single Input w /Relay 7 oz. 2 TRI -D Dual Input 7 oz. 2 Fire Safety Fire Safety 8 Fernwood Road 2 Kenview Boulevard Florham Park, NJ 07932 7/03 Brampton, Ontario Siemens Building Technologies Tel: (973) 593 -2600 5M Canada L6T 5E4 g g IeS FAX: (973) 593 -6670 SFS -IG Tel: (905) 799 -9937 July 2003 Fire Safety Website: www.sbt.siemens.com /fis Printed in U.S.A. FAX: (905) 799 -9858 supersedes sheet dated 1/03 WheelOC,k INC. Series E50 Speakers & Helping People Take Actions"' Speaker Strobes Description: Series E50 Speakers 8 Speaker Strobes are designed for high efficiency sound output with field selectable input voltage (25/70 VRMS) and field selectable taps from 1/8 to 2 watts. They are also designed to provide a sleek, aesthetic _ __ ... ' appearance for emergency voice /alarm communication ( �Lt:� systems. Strobe Options: F Single Candela Wall: 1575 cd q Multi Candela Field Selectable Wall: 15/30/75/110 cd or 135/185 cd ... Features: Series E50 Series E50 • Mount to 4" square x 2-1/8" deep backbox with no extension Speaker Strobe Speaker ring required • High efficiency design for maximum output at minimum . wattage across a listed frequency range of 400 to 4000 Hz • Strobes may be synchronized with Wheelocks S/v\ DSM Sync Modules or PS- 12/24 -8CP and PS- 12/24 -8MP Power Supplies with built -in sync protocol Specification and Ordering Information Note: Available October 2004 Order Wall Ceiling Strobe Grill Flush Mount Surface Agency Approvals Model Code Mount Mount Candela Color Backbox Mount Mounting Options Backbox UL MEA CSFM FM BFP E50 -W 0223 X X - White 4' x 4" x 2 -1/8" E5OSB -W E,O,P,Q,R,U,Y,AA * * * * * E50- 241575W -FW 0225 X - 15 (75 on Axis) White 4' x 4" x 2 -1/8" E50 -SSB -W E,Q,U,BB * * * * * E50- 24MCW -FW 0227 X - 15/30/75/110 White 4' x 4" x 2 -1/8" E50 -SSB -W E,Q,U,BB * * * * * E50- 24MCWH -FW 0229 X - 135/185 White 4' x 4" x 2 -1/8" E50 -SSB -W E,Q,U,BB * * * * * #See mounting options pull out guide in the last section of this binder. X Approved « Average RMS Current Pending d g E50 Strobe Current - Wall Mount E50 Speaker 241575W 24MCW 24MCWH • RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed Strobes 1575cd 15cd 30cd 75cd 110cd 135cd 185cd voltage range (16 -33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v 24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 units). For audibles the max current is usually at the maximum i listed voltage (33v for 24v units). For unfiltered FWR ratings, UL max* 0.090 0.060 0.092 0.165 0.220 0.300 .0420 see installation instructions. 08/04 2 3 B anchportAvenue Long - Branch _N 551'74 0 0) 6 803148 wwtN W eelockin c c b 2 -0 WheeiOC,k INC. Series RSS Strobes & Helping People Take Action Series RSSP Strobe Description: Plate Appliances Wheelock Series RSS Strobes provide a wide range of intensities and mounting options for wall or ceiling applications. Series RSSP Single & Multi- Candela Strobe Plates are designed for retrofitting existing audible notification appliances to strobe • applications. FIRE Strobe Options: Single Candela: 1575 cd (wall), 75 cd (weatherproofl =gJ Multi Candela Field Selectable Wall: 15/30/75/110 cd or 135/185 cd Ceiling: 15/30/75/95 cd or 115/177 cd FIRE FIRE Features: • Patented Universal Mounting Plate Series RSS F iR E • Low current draw to reduce power consumption and wiring costs • Strobes produce 1 flash per second over the regulated voltage range Series RSSP • Synchronize with Wheelockt S/vA, DSM Sync Modules or PS- 12/24 -8CP and PS- 12/24 -8MP Power Supplies with built -in sync protocol Specification and Ordering Information Model Model Agency Approvals Order Wall Ceiling Strobe 24 12 Square or Model Number Code Mount Mount Candela VDC VDC Color Color Mounting Options# Round Red White UL MEA CSFM FM BFP RSS- 24MCW -FW 9401 X - 15/30/75/110 X - - X B,D,E,F,GH,J,N,O,P,R,X Square X X X X X RSS- 241575W -FW 7788 X - 15 (75 on Axis) X - - X B,D,E,F,GH.J,N,O,P,RX Square X X X X X RSS- 121575W -FW 7468 X - 15 (75 on Axis) - X - X B,D,E,F,GH,J,N,O,P,R,X Square X X X X X _• }_ ; RSS- 24MCCR -FW 3159 - X 15/30/75/95 X - - X B,D,E,F,GH,J,N,O,P,R,X Round X X X X * RSS- 24MCCHR -FW 3463 - X 115/177 X - - X B,D,E,F,GH,J,N,O,P,R,X Round X X X * * RSSWP- 2475W -FR 9013 X - 180 77*F X - X - B,D,E,F,GH,J,N,O,P,RX Square X X X X * 75 ®31•F • RSSP- 121575W -FR 7798 X - 15 (75 on Axis) - X X - E,Z Square X X X X X • • • RSSP- 241575W -FR 7793 X - 15 (75 on Axis) - - X - EZ Square X X X X X #See mounting options pull out guide in the last section of this binder. Average RMS Current X = Approved • = Pending RSS/RSSP 24VDC 241575W RSS/RSSP Ceiling Mount C Wall Mount 24MCWH 24MCC 24MCCH �I Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd 24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 0.045 0.070 0.119 0.159 0.195 0.270 UL max* 0.090 0.060 0.092 0.165 1 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS /RSSP RSS/RSSP * RMS current ratings are per UL average RMS method. UL max current rating is the maximum 24VDC Wall Mount RMS current within the listed voltage range (16 -33v for 24v units). For strobes the UL max Models 121575W current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR 12 vdc 0.152 ratings, see installation instructions. UL max* 0.255 08/04 273Bran Ave nre Cog Branch ' NJ 07 00 631 2148 viww w ee oeklnr co ' 1 - FIRE SYSTEM FUNCTION MATRIX SIEMENS Washington Square Revision: 0 Starbucks xxxxxx SYSTEM RESPONSE 8 o m a) a a) o c co rn m c c co p o C E c r- C (7 E a7 C m — co a m m m a - E .t ,c E m a) al `m Q u a D rn c 45 u C _ N LL z, U a CO al 6 ❑ j (11 I -J Q O N ❑ �, a) (/) ❑ 0 o V) 0 0 O cp m D o E 9 a E E a o ( a @ o a m o O INITIATION DEVICE ACTIVATED Q � � Q � cn Q I— CO Area Smoke /Heat Detector X X X Air Handler Duct Smoke Detector X X X X Waterflow Switch X X X Valve Tamper Switch X X Fire System Trouble X X PROPRIETARY DOCUMENT FOR APPROVAL ONLY 4 10/13/2005 BATTERY SIZING CALCULATIONS SIEMENS Washington Square Starbucks Panel Name: FAPS -1 Battery Size: 7 amp -hr N1 -4 iirement for standby current: 24 hrs. Design Supervison Current = 1.44 amp -hr Requirement for alarm current: 15 min. Design Alarm Current = 0.94 amp -hr Spare Battery Capacity: 25 % Additional Capacity Current = 0.59 amp -hr Initiating Devices Assumed In Alarm: 10 % Battery AH requirement = 2.97 amp -hr PANEL EQUIPMENT Standby Alarm TOTAL TOTAL (ma) (ma) (ma) (ma) Quantity Device Current Current Standby Current Alarm Current Model PS- 12/24 -8MP _ 60 150 60 150 PANEL TOTALS 60 150 7 15cd STROBE 50 350 30cd STROBE _ 75cd STROBE 81 0 '` •~ .. 133 0 r r:ti}ti . 110cd STROBE f f; . � .. 161 0 8 15cd SPKR /STROBE ;N::::„§:§*;:, 47 376 2 3Ocd SPKR /STROBE : . ''~~'' 81 162 5 75cd SPKR /STROBE 130 650 12 110cd SPKR /STROBE 171 2052 .ti;.• . 0 FIELD TOTALS 0 3590 I: I I Standby Alarm I GRAND TOTALS (field & panel) I 60 I 3740 I Formula: [(A + B) x C] + [(D + E) x F] x G = Minimum Amp -Hour Battery Capacity Where:A = Internal panel standby current {amps }. B = External device standby current {amps }. C = Duration panel must remain operational {hours }. E = External device alarm current {amps }. F = Duration panel must remain in alarm after standby period ends {hours }. G = Spare battery capacity {percentage). PROPRIETARY DOCUMENT FOR APPROVAL ONLY 10/19/2005 • IAC CIRCUIT CALCULATIONS SIEMENS Washington Square Starbucks 261004 w w a - O a o _ m d 3 a 3 d d m A Q L 0 O . - m C O .0 O 0 C r• O 0, O O e O -4. 0 Q. =° �- d m d -0 y y v' O o m O Q y 4 C H J m C m p G 0 d O, d d , Y d J t: ` ? - -I O f!) N C C, y Of « « « C Y . ` Y Y a . ` 0 5 0 O J 7 C/) ( .0 V1 y J Q; J U N U1 y h t/1 ti h . y h N y a d C U O� d m g , J U • d d w d M o ur b� a Gh a a N a d U� O w w U C ti q M ., C L y C C H U V V O (i O c: C O C O O ? C> 0 m J k D; O` 1.2 9_ ti . �' . c 0, ° ^ .-� • - W Mtn r"'.9) .- W 0 N F > Q. 0 ° e O - F L x R R x 2 15 30 75 1 1 0 15 30 75 110 DH AU): # x l I x R 24 -VD FAPS -1 N1 -1 415 14 0.0026 1.08 2.16 2 0 0 0 4 1 0 5 0 0 1.40 3.01 20.99 12.6% 46.6% N1 -2 450 14 0.0026 1.17 2.34 0 0 0 0 0 0 4 0 0 0.73 1.71 22.29 7.1% 24.4% N1 -3 490 14 0.0026 1.27 2.55 3 0 0 0 3 0 4 2 0 0 1.34 3.42 20.58 14.3% 44.8% N1.4 480 14 0.0026 1.25 2.50 2 0 0 0 _ 1 1 1 1 0 0 0.60 1.50 22.50 6.3% _20.1% 50.9% 4.08 AMPS 7 8 2 5 12 Enter Pow 6 8.0 AMPS Capacity Per Output 1 3.0 AMPS) Enter Strobe Wire Size 14 Gua.e 1 5cd Strobe RSS Series .050 RSS - 24MCW -FW Multi - Candela Strobes 30cd Strobe RSS Series .081 75cd Strobe RSS Series .133 110cd Strobe RSS Series .161 @ 15cd Spkr /Strobe E50 Series .072 20.4 E50- 24MCW -FW Multi - Candela Speaker /Strobe 30cd Spkr /Strobe E50 Series .094 VDC 75cd Spkr /Strobe E50 Series .153 110cd Spkr /Strobe E50 Series .183 DOORHOLDER .096 150X OR EQUIVELANT (Supplied by Others) 24VDC RISER (AMPS) .000 Enter 24VDC Riser Wire Size 14 Guage PROPRIETARY DOCUMENT FOR APPROVAL ONLY 10/1912006