Specifications 9'3`f & 5 R� ao X33
Reliabia Bu l letin 121 Rev.l
co
c
Model G4 Concealed
5
Automatic Sprinkler
N
f
33
(D
G
The Concealer = .
A Concealed Sprinkler
With X" (13mm) or x ; . ..
1 %" (38mm) Adjustment - . -. 'v
Features
1. Push- on/Thread -off cover plate assembly =' ' '� ",;,,j. ?
N ? .°
{fi ;
attachment with 'h" (13mm) adjustment. !- ;`::; = . i
Does not require clips or springs. nh-
2. 1'/2" (38mm) Total adjustment provided by
z.
adjustable inlet versions. r - , a �'
3. Adjustable inlet version available with either ?,, • _ —
1" NPT ale or female threads eliminating ..
costly reducing coupling.
4. Smooth aesthetic ceiling profile.
5. Available in white or other color painted or The Concealer is designed for use where aesthetic ap
brass, chrome, or black plated finishes. pearance is important. Offices, hospitals, motels and res-
6. Ordinary and intermediate temperature taurants are but a few of the applications where it can be
ratings. used. It is available in different orifice sizes allowing the de-
g signer to optimize system performance, thereby achieving a
7. Multiple orifices for design flexibility. most efficient installation.
The Concealer can eliminate the need for precise cutting
of drop nipples. The Push -on /Thread -off cover plate assem- I
bly can be adjusted without tools so it mates accurately with
Approvals & Listings the ceiling. The fire protection system need not be shut
1. Underwriters Laboratories Inc. (UL) down to adjust or remove the cover plate assembly.
2. Underwriters Laboratories of Canada. (ULC) Product Description
3. N.Y.C. BS&A No. 587- 75 -SA. The Reliable Model G4 Concealer uses the proven
Note: Approvals are for light and ordinary hazard, except for Model G fusible element in a standard style sprinkler frame
small orifice sprinklers which are limited to light hazard with a drop -down deflector. This assembly is recessed into
occupancies. The cup and skirt are fabricated from plated the ceiling and concealed by a flat cover plate. The
steel and are intended for interior non corrosive applications. Push - on/Thread - off cover plate and sprinkler cup assem-
blies are held tight by a flexible tooth engagement to the
U.S. Patent No. 4,880,063. threaded cup. This threaded engagement provides Y2"
(13mm) of cover adjustment. The flat cover plate is attached
Application to the skirt using an ordinary temperature classification sol-
PP der. This results in a strong cover plate assembly with an or-
The Reliable Model G 4 dinary temperature rating, and an intermediate temperature
Concealer is the most versatile . sprinkler which can be installed in 150°F (66°C) environ-
concealed sprinkler available. It ments. When the ceiling temperature rises, the solder hold -
t i o
provides the best form of fire pro- ! ing the cover plate to the skirt melts, the flat cover plate
tec
tection while offering an attractive released thus exposing the sprinkler inside to the rising am-
appearance and ' /z" (13mm) of - bient temperature.
cover adjustment for ease of instal- . . The subsequent fusing of the sprinkler element opens the
lation. The adjustable 1" NPT inlet waterway and causes the deflector to drop into position to
versions have 1 y" (38mm) of total distribute the discharging water. Any secure engagement of
adjustment and a eliminates the need for a reducing cou- the threads between the cover plate and cup will assure that
piing. The small diameter Push-on/Thread-off cover plate the drop-down deflector is properly located below the cell -
assembly is easily attached and blends ds into the ceiling, con- ing when a sprinkler operates.
cealing the most dependable fire protection available, an
automatic sprinkler system.
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552
` Installation hex flats. After the ceiling has been installed with holes for the
Do not install The Concealer in ceilings which have positive sprinkler, each telescoping inlet section isto be adjusted with the
pressure in the space in the space above. G4 Wrench. Install the push-on/thread-off cover plate assembly
After a 2 inch diameter hole is cut in the ceiling, the sprinkler over the sprinkler by holding and pressing it straight up into the
is to be installed with the Model G4 Wrench. The wrench has cup. Anal adjustment of each cover assembly is made by hand
drive tangs which insert into cup slots. When installing a sprin- timing it clockwise until it is tight against the ceiling.
kler the wrench is first positioned into the sprinkler /cup assembly Maintenance
until the wrench tangs engage drive slots in the top of the cup The Model G4 Concealer" should be inspected quarterly and
(there are two sets of mating drive slots in the cup). The sprinkler the sprinkler system maintained in accordance with NFPA 25.
is then tightened into the pipe fitting. When inserting or remo ing D not clean sprinklers with soap and water, ammonia or any
the wrench from the sprinkler /cup assembly are should be other cleaning fluids. Remove any sprinkler that has been
taken to prevent damage to the sprinkler. DO NOT WRENCH painted (other than factory applied) or damaged in any way. A
ON ANY OTHER PART OF THE SPRINKLER /CUP ASSEMBLY. stock of spare sprinklers should be maintained to allow quick re-
The adjustable inlet versions are similar to the standard Model placement of damaged or operated sprinklers. Prior to installa-
04 except that an addition 1" (25mm) of adjustment is provided tion, sprinklers should be maintained in the original cartons and
by means of a telescoping inlet section that threads in or out of a packaging to minimize the potential for damage to sprinklers that
stationary coupling reducer (either 1 male or 1 female) as shown would cause improper operation or non- operation.
I in Ag. 2 or Ag. 3. These sprinklers must be installed before the t , 1
ceiling is in place, by wrenching on only the coupling reducer Ordering Information Cover Plate Finishes
1. Sprinkler Model Standard Finishes
Temperature Ratings 2. Temperature Rating Bronze
3. Nominal Orifice Chrome Plated
Max. Ambient 4 Flat Cover Plate Finish White
Classification Sprinkler Cover Plate Temp. 5. Inlet Type
Note: Unless otherwise Special Application
Ordinary 135 °F /57 °C 135 °F /57 °C 100F/38°C specified, the 165 °F (74°C) Finishes
Ordinary 165 °F /74 °C 135 °F /57 °C 100 °F /38 °C sprinkler will be provided with Black Plated
Ordinary 165FT74°C 165FI74°C 100 °F /38 °C the 165 °F (74°C) cover. Bright Brass
Intermediate 212 °F /100 °C 165 °F /74 °C 150F/66°C Off White
Installation Data Black Paint
Nominal Sprinkler "'Otter colors and finishes are
Sprinkler Total Nominal , K Factor Thread APt Identification available. Consult factory for
Inlet Adjustment Orifice US Metric Number
(SI details
Non - Adjustable )"( 13mm) )"(15nvn) 5.6 80 X" NPT (Rf) 1,2,3 R2115 Note: Paint or any other
_ Non - Adjustable ) "( 13mm) 4'"(11rrrn) 42 60 X " NPT (Ry) 1,2,3 R2113 coatings applied over the
Non - Adjustable ) "(13mm) %"(1 ) 2.8 40 y " NPT (R'h) 1,2 R2111 factory finish will void all
• Adjustable 1y "(38mm) ) 1"(1 5 mm) 5:6 80 1 " NPT Male or Female 1,2,3 R2118 approvals and warranties.
__ Adjustable 1y "(38mm) T4 "( 42 60 1 "NPT Male or Female 1,2,3 R2113
Adjustable 1y "(38mm) 3e" ( 1 ^) 2.8 40 1" NPT MalecrFni,ale 1,2,3 R2112 Installation Wrench
Model G4 Spnnkler Wrench
WM.
r— _ , , ' '
Q s VI' WOMO
m —). , + — — I
( II
.r i a lt1rt
0.1070.0. OP ..,,•_
III laZOW.
E i1■LI J NCI.. a Y[ f :��I m 17 71 ■ t 1 �If -- �� �'f - 111
.. f 1101:2 Al I I M , i ' l�i�l1:! Iiiiii
-1... —
r � — -- _- _ -.�..
MIM Mom
Fig. 1 - %" (R /) NPT Non- Adjustable Inlet Fig. 2 - 1" NPT Male - Adjustable Inlet Fig. 3 - 1" NPT Female- Adjustable Inlet
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries
Manufactured by
The Re liable Automatic Sprinkler Co., Inc.
Re Iiabk a
(800) 431-1588 Sales Office
(800) 848-6051 Sales Fax
(91914) 668 8 33470 Corporate orate Offices Revsion , indicate updated ix new data
www rehablesprmkler com Internet Address EG Printed m LISA 0602 PM e999970014
I
' Bulletin 110 Rev.S
_ Model G co
i 77 1 Automatic Sprinkler
Spray Upright,
•
L Spray Pendent ° ro
_,
And Conventional <
cn
Product Description
The Reliable Model G Automatic Sprinkler utilizes the
center strut solder in compression principle of
construction. The fusible alloy is captured in the
cylinder of the solder capsule by a stainless steel ball.
When the fusible alloy melts, the ball moves into the
cylinder allowing the cylinder to fall away from the
l t
sprinkler. When this happens, the lever is released to
spring free from the sprinkler so that all of the operating ._.
parts clear from the waterway allowing the deflector to
distribute the discharging water. • -
Except for the parts in the cylinder as mentioned
above, the sprinkler components are made from Upright Pendent
copper based alloys for maximum corrosion ,
protection. Lead plated, wax coated or wax over lead
plated sprinklers are available for specially severe
environments. Chrome plated sprinklers are available
for decorative purposes.
All sprinklers are individually hydrostatically tested.
All sprinklers are identified as to their fusing point by ,
markings that appear on several of the operating parts ,
and by an identifying color that appears on the frame.
Sprinkler Types . Ir.
Standard Upright - This deflector configuration is Small Orifice Upright Conventional
normally used with exposed piping installations. Water
is distributed laterally and downward in a wide pattern
approximating a hemisphere which is completely and
uniformly filled with water in the form of small drops or
spray.
Standard Pendent - This deflector configuration is Application and Installation
normally used where the space above the piping is Standard sprinklers are used in fixed fire protection
I limited or where a concealed piping installation is systems: Wet, Dry, Deluge or Preaction. Care must be
employed. The discharge characteristics of the exercised that the orifice sizes, temperature ratings,
standard pendent are virtually identical to the deflector styles and sprinkler spacings are in
standard upright as described above. accordance with the latest published standards of the
National Fire Protection Association or the approving
Large and Small Orifice—By varying the orifice size, authority having jurisdiction.
a large or small orifice sprinkler is created that will The sprinklers must be installed with the Reliable
distribute as much as 40% more water or 65% less Model D Sprinkler Wrench. Any other type of wrench
water than the normal' /2" (15mm) orifice sprinkler. may damage the sprinkler.
The approvals or listings of Reliable Automatic
Conventional —This deflector configuration is used Sprinklers by major approving organizations are
primarily in those countries where the LPC installation shown in the tabulated list provided on the back of this
rules have precedence. The sprinkler is designed to bulletin.
distribute a portion of its water discharge upward
against the ceiling with the balance downward. It may
be installed in either the upright or the pendent
position. Sprinklers with conventional deflectors are
available with orifice sizes corresponding to light, 'Patent No 4,440,234
ordinary and extra -high hazard installations.
The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552
Technical Data
"K" Factor Sprinkler Identification
Sprinkler Number (SIN)
Sprinkler Type US Metric Height Approvals SSU SSP
Standard- Upright (SSU) and Pendent (SSP)
Deflectors Marked to Indicate Position
X" (15 mm) Standard Orifice with y," NPT (Ry) Thread 5.62 81.0 2'/" (73 mm) 1, 2, 3, 4, 5, 6, 7 R1025 R1015
< (11 mm) Small Orifice with y" NPT (Ry) Thread 4.24 61.0 2 %" (73 mm) 1, 3, 7 R1023 R1013
X" (10 mm) Small Onfrce with y" NPT (Ry) Thread 2.82 40.6 2 %" (73 mm) 1, 2, 3, 7 R1021 R1011
/ 6 " (8 mm) Small Orifice with y" NPT (Ry) Thread 1 98 28.5 2 %" (73 mm) 1, 3, 7 R1022 R1012
1 % 7 z' (20 mm) Large Onfice with y" NPT (Ry) Thread 7.96 114.7 2' /a" (73 mm) 1, 2, 3, 7 R1026 R1016
1 % 3 2' (20 mm) Large Orifice with y," NPT (R',)Thread 8.20 118.2 2'%" (75 mm) 1, 2, 3, 7 R1027 R1017
20 mm XHH with 20 mm Thread 8.20 118.2 75.4 mm 4, 5, 6 R1027 R1017
10 mm XLH with 10 mm Thread 4.10 59.1 73 mm 4, 5, 6 R1024 R1014
Conventional—Installed in Upright or Pendent Position
10mm XLH with 10mm Thread 4 10 59.1 73 mm 5 R1074
15mm Standard Orifice with (Ry) Thread 5.62 81.0 73 mm 4, 5, 6 R1075
20mm XHH with (R3;) Thread 8.20 118.2 75 4 mm 4, 5 R1077
Temperature Ratings Maintenance
Maximum Model G Sprinklers should be inspected quarterly and the
Sprinkler Ambient sprinkler system maintained in accordance with NFPA 25. Do
Rating Temperature Fra (1) not clean spnnklers with soap and water, ammonia or any other
Classification °F °C °F °C Color cleaning fluids. Remove any sprinkler that has been painted
Ordinary 135 57 100 38 Black (other than factory applied) or damaged in any way. A stock of
Ordinary 165 74 100 38 Uncolored spare sprinklers should be maintained to allow quick replace -
Intermediate 212 100 150 66 White ment of damaged or operated sprinklers. Prior to installation,
High 286 141 225 107 Blue sprinklers should be maintained in the original cartons and
packaging until used to minimize the potential for damage to
(1) Frame color does not apply to painted or plated sprinklers sprinklers that would cause improper operation or
-Use sprinkler rating as identified on operating parts non-operation. Use only the Model D Sprinkler Wrench for
spnnkler removal and installation. Any other type of wrench may
damage the sprinkler.
Finishes
Standard Finishes Approval Organizations
Bronze —All Temperature Ratings 1. Underwriters Laboratories, Inc.
Chrom —All Temperature Ratings 2. Factory Mutual Research Corporation
White (`) —All Temperature Ratings 3. Underwriters' Laboratories of Canada
Only Frame and Deflector are Painted 4. Loss Prevention Council
Special Application Finishes 5. Pleniere Assemblee
Bright Brass Plated —Only frame, deflector and cap are plated. 135 °F (57 °C), 165 °F
6. N.Y.C. S Sch No. 5 7-75—SA or gg
Bri
9 y 7. N BS &A No. 587 —
(74 °C), 212°F (100 °C) Temp. Rating. N.Y.C. MEA 258 -93 -E
Black Plated —Only frame, deflector and cap are plated. All Temp. Ratings.
Polyester Coated ( � —Only frame and deflector are coated.
Lead Plated —165 °F (74 °C), 212°F (100 °C) and 286 °F (141 °C) Temp. Ratings. Ordering Information
Wax- Coated (3) —165 °F (74 °C) Clear Wax, 212 °F (100°C) Brown Wax. Specify
Wax - Coated Over 1. Model G
Lead Plated 13) —165 °F (74 °C) Clear Wax, 212°F (100 °C) Brown Wax. 2. Deflector
• Upright
( Other colors and finishes are available. Consult factory for details • Pendent
( UL listed and NYC MEA Approved only • Conventional
(3) 212°F (100 °C) brown wax may be used on 286 °F (141 °C) 3. Nominal Orifice
sprinklers when maximum ambient temperatures do not exceed 150 °F 4. Inlet Thread
(66 °C). UL Listed, FM Approved, NYC MEA 258 -93-E. 5. Temperature Rating
6. Finish
The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Are Protection Association. Factory Mutual
Research Corporation. or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable
Products manufactured and distnbuted by Reliable have been protecting life and property for over 80 years. and are installed and serviced by the most highly qualified and
reputable sprinkler contractors located throughout the United States. Canada and foreign countries.
Manufactured by
T Reliable Automatic Sprinkler Co, Inc.
Re I jab I (800) 0) 431 -1588 848 Sales Offices
(80 6051 Sales Fax
(914) 668 -3470 Corporate Offices Revision lines indicate updated or new data
www rehabiespnnkier.com Internet Address EG Printed in U SA 11p9 PM 9999970005