Loading...
Permit CITY TIGARD BUILDING PERMIT PERMIT #: BUP2007 - 00496 COMMUNITY DEVELOPMENT DATE ISSUED: 10/11/2007 TIGARD 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 1S12600-00300 SITE ADDRESS: 09302 SW WASHINGTON SQUARE RD V05 ZONING: C - SUBDIVISION: WASHINGTON SQUARE LOT: JURISDICTION: TIG PROJECT: LUCY Project Description: TI REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: ALT FIRST: 2,867 sf N: S: E: W: TYPE OF USE: COM SECOND: sf PROJECT OPENINGS? TYPE OF CONST: 2N sf N: S: E: W: OCCUPANCY GRP: M TOTAL AREA: 2,867 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: 78 BASEMENT: sf AREA SEP. RATED: STOR: 2 HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: Y SMOK DET:Y DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : Y HNDICP ACC:Y BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: VALUE: $ 450,000.00 Owner: Contractor: WASHINGTON SQ. LLC ELDER JONES INC 9585 SW WASHINGTON SQ. RD. 1120 E 80TH ST #211 TIGARD, OR 97223 BLOOMINGTON, MN 55420 Phone: Contact #: PRI 952 - 854 -2854 Reg #: LIC 64459 FEES Description Date Amount REQUIRED ITEMS AND REPORTS [BUPPLN] Pln Rv 9/21/2007 $1,070.36 [FLS] FLS Pin Rv 9/21/2007 $658.68 [BUILD] Permit Fee 10/11/2007 $1,646.70 [TAX] 8% State Surcha 10/11/2007 $131.74 (additional fees not listed here) Total $4,047.48 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling 503.246.6699 or 1.800.332.2344. Issued By: �A , /lr Permittee Signature Call 503.639.4175 by 7:00 a.m. for an inspection that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. fi . A ' • t Building 3� 2_4503 ' ` �� ding Permit Application Commercial FOR OFFICE USE O - City RECE Permit N `J g DateBea - illig Ci of Ti and 9' _ . . 0 e `� - ,s q 13125 SW Hall Blvd , Tigard, OR 97223 Plan Review : , C Phone: 503 639 4171 Fax: 503 598 19 8 ) E P 2 1 2007 Date /By Other Pertniyqpi D Dop7_ Inspection Line 503 639 4175 Date Ready /By ■ / Jury El See Page 2 for ""�o l' I G A R L No ied/Met .d / �� D 7 Su lemental Information Internet. www tigard -or gov CITY OF FIGAF D PP Bumnu (fln�Is;Or? �,,,' %' w/ ( t TYPE OF WORK -- RE ULRED DATA:1 -•AND 2- FAMILY DWELLING ❑ New construction ❑ Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all 1%Addit' alteratio replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ❑ 1- and 2- family dwelling Commercial /industrial Valuation: $ ❑ Accessory building ❑ Multi - family Number of bedrooms: El Master builder ❑ Other: Number of bathrooms: - 'JOB SITE INFORMATION AND LOCATION ' Total number of floors: Job site address: 3 Sal 4), z )6/1 New dwelling area: square feet City /State /ZIP: / `! �,�e D� Garage /carport area: square feet Suite/bldg. /apt. no.: ' 7' / ` b Project name: � L Covered porch area: square feet Cross street/directions job site: Deck area: square feet Other structure area: square feet - REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. �% / / Valuation: $ �� z k X/7 /2.GcQ�7 � �f�C e., ' it I-Gv71q/itiii^ rlieu ✓'!>T7r7v..S Existing building area: square feet New building area: square feet ❑ - PROPERTY OWNER - g TENANT Number of stories: Name: L r Type of construction: Address: 3 / 3 fo I,J / w1, 4r P a ` S' f _ _ -- Occupancy groups: City /State /ZIP: ,4L-/ tJ e9� 7,..;2/ 0 Existing: Phone: ('4) 3) c ,,, ag, a' g j Fax: ( ) New: . ' ' ,g APPLICANT - ❑ 'CONTACT PERSON - NOTICE Business name: j /5, /6/P"/Gt All contractors and subcontractors are required to be Contact name: � licensed with the Oregon Construction Contractors Board 7 under ORS 701 and may be required to be licensed in the Address: � Se" hut.. /3/' Y � ,,Z jurisdiction in which work is being performed. If the i applicant is exempt from licensing, the following reasons City/State/ZIP: 4 - 24 92` / apply: Phone: ( ,3) 3 -/ 7 t 2 Fax: : / ( �?.3 ) X91 — ,.26, 30 E-mail: vLt/1Gfi "��3 , 'j / 5.GU:t.� d .6iii,-- CON CTO R - Business name: vrig_g_- . BUILDING PERMIT FEES* Address: //' (Please rejaw fee schedule) . City /State /ZIP: Structural plan review fee (or deposit): 1,0 , 3 (p Phone: ( ) I Fax: ( ) FLS plan review fee (if applicable): 65.. 4,5? CCB lic.: Ca Li (i sI / ea _ a..1 � � 1 r ( O Total fees due upon a Tp . Amount received: .ii 7a9.o� Authorized signature: �/' / fv ``.�° This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: „) „7- Date: of / O7 * Fee methodology set by Tri -County Building Industry Service Board I•\ Building \Permits\BUP- COM.PermitApp.doc 2/23/07 440- 4613T(I 1/02 /COM/WEB) Building Division • Accessibility: Barrier Removal Improvement Plan .T.; G A R, D REQUIREMENT: OREGON REVISED STATUTE (ORS) 447.241. (1) Every project for renovation, alteration or modification to affected buildings and related facilities shall be made to insure that the path of travel to the altered area and the restroom, telephones and drinking fountains are readily accessible to individuals with disabilities unless such alterations are disproportionate to the overall alterations in terms of cost and scope. (2) Alterations made to the path of travel to an altered area may be deemed disproportionate to the overall alteration when the cost exceeds twenty-five per -cent (25 %). VALUATION: Total of all renovation, alteration or modification being done, excluding painting and wallpapering: [1] $ MULTIPLIER (25% barrier removal requirement): x .25 TOTAL BUDGET FOR BARRIER REMOVAL: [2] $ ELEMENTS: In choosing which accessible elements to provide under this section, priority shall be given to those elements that will provide the greatest access. Elements shall be provided in the following order: (a) Parking $ (b) An accessible entrance: $ (c) An accessible route to the altered area: $ (d) At least one accessible restroom for each sex or a single unisex restroom: $ (e) Accessible telephones: $ (f) Accessible drinking fountains: and, $ (g) When possible, additional accessible elements such as storage and alarms: $ TOTAL (shall equal line [2] of Valuation Computation): $ 1 \Building \ Permits \BUP -COM PcrmitApp doc 02 /23/07 la 1 Q (4 Paoo - 7 • Form 2a Project Name: Lucy - Washington Square (Tigard, OR) Page: SUMMARY ULUS 4'BAs,",P ..RKi7u tFM i i a 'T3 Rr kY s' °111WIsMMTVA' MMET, t irtUir:Y E4aVittaff.t°^.' !`': alWai f?' PAPAMO I .4.wu' i Project 1. Project Name Lucy - Washington Square 2. Project Address 9585 SW Washington Square - Space T11 3. City/Town Tigard 5. County Washington 4. Building, Gross Area (ft2) 2,640 6. No. of Floors 1 1 7. Construction Site Elevation Above 2,000 ft? ❑ YES ENO A Attached Chapter Type ID Description Attach ,Forms s and Building Envelope Form 3a Building Envelope - General ❑ ®r�S�fleet3 3b Prescriptive Path - All Climate Zones ❑ 1 * CodeComp Report for Simplified Trade -off ❑ * In lieu of 3b * Floppy disc with .occ CodeComp file ❑ Check boxes to m ...._,___._.._...:_._..,.._ _..__.� �._...__ _ ._._ ._ ._,i Worksheet 3a Wall U- factor El indicate attached 3b Roof U-factor El 1 forms and 3c Floor U- factor ❑ worksheets 3d Window /Skylight Schedule ❑ Systems Form 4a Systems - General 0 4b Complex Systems ❑ Worksheet 4a Unitary Air Conditioners - Air Cooled ❑ � 4b Unitary Air Cond. - Water & Evap Cooled ❑ . 4c Unitary Heat Pump - Air Cooled ❑ 4d Unitary Heat Pump - Water Cooled ❑ 4e Packaged Terminal A.C. - Air Cooled ❑ 4f Packaged Terminal Heat Pump - Air Cooled ❑ 4g Water Chilling Pkgs - Water & Air Cooled ❑ 4h Heat Rejection Equipment ❑ 4i Boiler - Gas -Fired and Oil -Fired ❑ 4j Furnace & Unit Heaters - Gas and Oil -Fired ❑ 4k Simultaneous Heating and Cooling ❑ 41 Air Transport Energy ❑ 4m Natural Ventilation ❑ Lighting Form 5a Lighting General 0 5b Interior Lighting Power - Tenant Method ❑ 5c Int. Ltng. Power - Space -by -Space Method 0 Worksheet 5a Lighting Schedule 0 5b Interior Lighting Power p s18Fi3'ilY1$4W9St tiAG.Ti990U4t^li0Ra47 'SrT'1QFSCiNTA9t .. ^"'^ .f4:iCR ]'SSfi. .A' ..,„s. iS.Y[RII1:Si4T.eir id3cha"7t.AtY.,tiIIY .,.CSSG:AA:t!....?3,S'.fi : cLY'An1 ........I:A.L,,,.. . iktJ;Y9.GPi3t . Applicant 7. Name 10. Telephone 8. Company 11. Date 9. Si•nature i iXl 6RiV VClY7.7 *ZiCi3is.9E3Iff961:11:17,01g 4`1.7•{VSi' - tWar 31•^ .F :1 11/610/FLIntsm`9KSdta& IT iarl ?e'MTAIOr.S:+.47i'17ri7.^3 -v^'; AiP`1Ra'N0121=RA.4tlti1 -1:11 il�ii7At7Fi .a.16GM314E2S. -A Attached No of Pages Description of Documentation Document - ation w" azv u -e-zat ma _t5m p iveiz go't3J::ilmni usgmmS}na -wi w X14 C?, ' "fre.m - i ?�4F 3';— eia.. .. a sawgram:Al , • Form 4a Project Name: Lucy - Washington Square Page: 1 SYSTEMS - GENERAL Applicability Plans /Specs Discussion of qualifying exceptions Show compliance by including a drawing sheet, detail number, on page 4 -25 specification section and subparagraph 1. Applicablity (Section 1317) • Is this form required? O Form Required. Complete form if a new HVAC system is being installed, or components of an existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1 Portions of the building that qualify: Area- Exception 0 -1 0 -2 0 -3 Area • Exception 0-1 0 -2 0-3 Area: Exception 0 0 0 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) 2 Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) O No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. ❑ Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: ❑ -4a ❑ -4b ❑ -4c ❑ -4d ❑ -4e ❑ -4f ❑ -4g ❑ -4h ❑ -41 ❑ -4/ a...L.7....sue.e...uN.«n A11.1w..17104 s�"......a.eaee27...nevi..n R.I. /......1 .wM.aan...w..mnn.r.,< aim+ mmr s.+.. waaam.. nw..m v.. n„- .u..ha cvwUILSTIa.e.671 ,r.. 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. D Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as required by Sections 1317.7 &1317.8 RJi..'ew.R .'....]ard./.14.1.:...1. SO 114.5W_IT.M.113,L MS.wYK4,1 1. 141617.144,1,....1,, .S -.•,. , ••'.�..sn9S.Yf WS6i/ .41.0111.13 .:.. 1441, /:. .YYNIC...w .164 ,.a.P-.43.0. 5. Distribution Transformers (Section 1316.1) O No Distribution Transformers. The plans /specs do not call for new distribution transformers ❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section - 1316.1.1. ❑ Exception. The project qualifies for an exception per Section 1316 1.1, Exceptiion: ❑ - 1 ❑ -2 ❑ -3 ❑ -4 ❑ -5 ❑ -6 ❑ -7 ❑ -8 ❑ -9 ❑ -10 ❑ -11 ❑ -12 ❑ -13 ❑ -14 Attach relevant documentation for appropriate exception. The plans /specs show compliance in the following T locations: sc, s.S .37 -5- .•o. i; g aZ'8f4l 111i1aR%rt:Wii ' .I.Vel.. .Te i7u+i''-.5��irfi1''n.'r315. k: cti. ir.t ti::,*' -IIY'.4B .; : '[S'li 3'stliJr:. sa`b""�'attc+c +ais'•Int8: 4 -1 Compliance with OSSC, effective 04/01/07 • Form 4a Project Name: Lucy - Washington Square Page: 2 SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) 6.1 System Thermostat /Zone Controls (Section 1317.4.1) O Complies. All new HVAC systems include at least one temperature control device responding to temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4 2, Exception ❑ -t 0 -2 Portions of the building that qualify: The plans /specs show compliance in the following locations: M1 6.2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3) O Complies. Systems must have at least one of the following features O Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces served. ❑ Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: ❑ Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) ❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception 0-1 0-2 The plans /specs show compliance in the following locations: M1 6.3 Control Capabilities (Sec. 1317.4.2.1) O Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements. The applicable code exception is Section 1317.4.2.1 Exception 0- 0 -2 Portions of the building that qualify: The plans /specs show compliance in the following locations. M1 6.4 Optimum Start Controls (Section 1317.4.3.2) ❑ Complies. Separate HVAC systems have controls capable of varying start-up time of system to just meet temperature set point at time of occupancy. O Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: M1 6.5 Heat Pump Controls (Section 1317.4.4) El No Heat Pump. The plans /specs do not call for a new heat pump ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4 F'r The plans /specs show compliance in the following locations' • M1 B'Jr3r 4 *,Ca zJta.fi., f,21:.«a'x!t? +.'..:fig! Y;;: GU.' taKltlF4�iid= A+ s' AAfF3`' t; �A! l�: Fiu' 9. Si?s. Xidl; a6G4. RE. 7L 'idtE['�ilW�h's':iCY11k%a�+i!R iLS; t: lS: fi.,= Ci_ t' f1'. E�: i1r�ETIX� :.iz�11ltL:ri'+: 4 -2 Compliance with OSSC. effective 04/01/07 Form 4a Project Name Lucy - Washington Square Page 3 SYSTEMS - GENERAL i 7. Economizer Cooling (Section 1317.3) D No Cooling. The building plans do not call for a new fan system with mechanical cooling. ❑ Complies. Each new fan system has an air economizer capable of modulating outside -air and return -air dampers to provide up to 100 percent of the design supply air as outside air. ❑ Exception At least one new fan system qualifies for an exception. The applicable code exception is Section 1317 3, Exception ❑ -t 0 -2 0 -3 0 -4 ❑ -s 0 -6 0 -7 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu /hr) (b) Total installed building cooling capacity (Btu /hr) ❑ Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 Btu /hr or a/b < 0.10 (10% of total building cooling capacity). Unit Identifier of exempt units The plans /specs show compliance in the following locations: M1 S. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2) D No Economizers Required. Project does not contain a new fan system requiring economizers. ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer ❑ Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. ❑ Exception. The applicable exception is Section 1317.3 2, Exception 0 -1 0 -2 The plans /specs show compliance in the following locations M1 9. Hot Gas Bypass (Section 1317.5) D No Hot Gas Bypass ' ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity Allowable Hot Gas Bypass %e • o Rated Cooling Capacity Max Hot Gas Bypass Capacity ' a:' <240,000 Btu/ hr 50% ^°'' >240,000 Btu/ hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h — == -tia armiem, : s er e. metae rmv.~ s ar � xwar . k.4a . isiati: t 4 -3 . Compliance with OSSC, effective 04/01/07 Form 4a Project Name: Lucy - Washington Square Page 4 SYSTEMS — GENERAL 4�fflli"�R:111£F J:K:T+XS.YR �;.Wl'- ,7dY:+S2EfL'X7 zz X131`ei"Jf.57i?rt!'dF......,:.. -, r, yr ..QdA1WlFI!s.?a"iiDSsvlE .,7E4L+ M4.......Alb° J( ai' _h?Rl4'Jf?3fi4+�6W1�L�!»`4T:'4'. 'iJiL.. 10. Shutoff Dampers (1317.4.3.3) ❑ Not Required. Shutoff dampers are not required on this project. 1E1 Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers ❑ Exception. The building qualifies for an exception to the motorized damper requirement. The applicable code exception is Section 1317.4.3 3 Exception 0 -1 0 -2 0 -3 0 -4 ❑ -5 0 -6 The plans /specs show compliance in the following locations: M1 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) ❑ Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. ❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. The plans /specs show compliance in the following locations M1 10.2. Motorized Damper Leakage (1317.4.3.3.2) CI Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998 ❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: M1 11. Piping Insulation (Section 1314) ID No New Piping. The building plans and specifications do riot call for new piping serving a heating or cooling system or part of a circulating service water heating system. El Complies. All new piping serving a heating or cooling system or part of a circulating service water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for exception: Section 1314.1, Exception 0-1 0-2 . , , - ,...b,.- „,w....,.., ,w„r,..W.,� ..., - �.........x:.—... —mom, ,_.— ..,.,-.,,,,.:w�, •- - ,,: ..:.,�,e . 12. Occupancy Ventilation t J Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated in plans /specifications as specified in Chapter 4 of the Oregon Mechanical Specialty Code. ❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section1203 4.1, Exception. Attach worksheet 4m. The plans /specs show compliance in the M1 following locations The plans /specs show compliance on the following pages: 1 e ._ .. d..-- os iP:1smirit, _rdF 72i ee °�aYS#.'"i'Si7lE'iG ezeorro Y _�rex"Titarrr1 ?wYSiEfFai3ltsadn'ialt.5. i'On 7#MakVie !` , e... ..47.AVIPMEINrIMNI 4 -4 Compliance with OSSC, effective 04/01/07 Form 4a Project Name Lucy-Washington Square Page 5 SYSTEMS - GENERAL "E"fattftrri#1 f .Fh70:2:Hnia11 17[ iiMIS\71ATZSNOMAJWIN firi'> a3'W-_S VaM 7EN4S9. LL- iT✓ YtNtlK4i6lX *Voi.7Y.- _b.sME FIT "• • ttl '••'VOMI'Gi..l" iCil^'_iklt.stetilEtleg C' .IL". 16L'EMIO AVIRRIISM- 13. High Occupancy Ventilation (Section 1317.2.2) ❑ Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas having an average occupant load of 20 square feet per person or less from Table 1004 1.2 have a means to automatically reduce outside air intake. Identify applicable systems' Plans /specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified' ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. O No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Exhaust Air Heat Recovery (Section 1318.3) O Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air supply. ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception 0_1 ❑ _z 0=3 0 -4 0 .5 0-6 0 -7 The plans /specs show compliance in the following locations: M1 15. Large Volume Fan Systems (Section 1318.4.2.4) p Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following locations: M1 16. Variable Speed Drives (Section 1317.10.3.1) �a.... ...,.°..a.....�„r..n.M... ..a.7 „ I] Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317 10 3.1, Exception The plans /specs show compliance in the following locations: M1 17. Service Water Heating (Sec. 1315) El No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. ❑ Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315 ❑ Exception. The applicable code exception is Section: Exception: '.! : Portions of the building that qualify - ° The plans /specs show compliance in the following locations ie" n.ma ,..aiivix ' vir: ssmsgiwzT!L okincs4923. weiGomoF,' tltrzi!ualyW 1 'vimeatr1FtimiP,'a'L aaix4MPtS�.'XGSa g iiiuste Y _:.FISi�'4d rJ14F.�w12't3i£u:l 4 -5 Compliance with OSSC, effective 04/01/07 • Form 4a Project Name: Lucy - Washington Square Page 6 SYSTEMS - GENERAL 18. Swimming Pools, Spas and Hot Tubs (Section 1315.5) El No New Pools. The building plans and specifications do not call for new, swimming pools, spas or hot tubs. ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5 3 ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season 19. Fume Hoods (Section 1317.2.1.) • No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: ❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318 3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: .. �, , ,,�,:� ... ,.. ra r, �, .. �,.., ,.; °tea... ,,.» , �.A.w. • • :���,a �: .�R� b p. -.., WI�. ° ..,� 20. Parking Garage Ventilation (Section 1317.2.3) ❑ No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) O Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. El Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled The plans /specs show compliance in the following locations: gr . I.o�a. .. . . ......m. .r.werca.....,!....... H..: 'o i....1 *r.[K ..•....o la.mmf ,.-11.x.wwwl. w:mrct!rvrYnM' as ?us..41.4:.C [ 22. Outside Heating Systems (Section 1317.12) O No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. ❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12 !FMSinii. ? nermat yelignir !a i—vsmisiS wo3 3I 2G� t. s1 rT� +. mix •v+ l�k : i fs s i n 4 -6 Compliance with OSSC, effective 04/01/07 • Form 5a Project Name Lucy Page LIGHTING - GENERAL. 1. Interior Exceptions (Section 1313.1) El No Interior Lighting. The building plans and specifications do not call for new or altered interior lighting Skip to item 5, Exterior building Lighting - General, below Exceptions ❑ Exceptions. 1 The building or part of the building qualifies for an exception from code lighting Discussion of quaidyeg exceptions requirements Applicable code exception is number in instructions section 2 Lighting equipment that qualifies for an exception - in addition to general lighting and is separately controlled. Applicable code exception is number Areas of the building and equipment that quality for any exceptions Plans /Specs Show compliance by including a Sheet El drawing sheet, detail number, and /or specification section and subparagraph 2. Local Shut -off controls (Section 1313.3.1.1) El Complies At least one local Shut - Ott lighting control for every 2,000 square feet of lighted floor area and for all spaces enclosed by walls or ceiling height partitions This control is detailed in the building plans on drawing number ❑ Exception. I he building or part of the building qualities for an exception Applicable code exception is Section 1313 3 1,1, Exception Portions of the building that qualify 3. Automatic Shutoff Controls (Section 1313.3.1.2) O Not Applicable. Office floor area is not over 2,000 square feet of contiguous office floor area or permitted space is not over 5,000 square feet No offices less than 300 square feet, meeting or conference rooms, or school classrooms ❑ Complies. All interior lighting systems are equipped with a separate automatic contralto shut off lighting dunng unoccupied penods Offices less than 300 square feet, meeting and conference rooms, and school classrooms are equipped with occupancy sensors that comply with Section 1313 3 1 2 1 Compliance details in plans /specs• ❑ Exception. I he building or part of the building qualities for an exception. Applicable code exception is Section 1313 3 1,2, Exception Portions of the building that qualify 4. Daylighting Controls (1313.3.1.3) O No classrooms or atriums with skylights or window to wall ratio greater than 50 %. ❑ Complies All classrooms and atriums with window to wall ratio greater than 50% and /or skylights are equipped with automatic daylight sensing controls, as required by Section 1313 3.1 3 1 and Section 1313 3 1.3 2 The daylight sensors specified comply with Section 1313 3 1 3 3 Compliance details in plans /specs Exterior Build - ing 5. Exterior Lighting (Section 1313.5) Lighting 3 Compiles I he plans do not call for use of incandescent or mercury vapor lamps for use on building exterior Is lighting directed to Illuminate the Exception. I he building plans indicate luminaires with incandescent or mercury vapor lamps, but are exlenor of the building and adjacent ❑ walkways and loading areas with or specified for use in or around swimming pools, water features, or other locations subject to requirements without canopies of Article 680 of the 2002 National Electrical Code Clock Switches shall be .._, _....�._. ... _. __ . _.. __ .._ ... _ _. _ . .,._.___�_ astronomic (seasonal correcting) type with separate programs for each day 6. Exterior and Canopy Lighting Controls (Section 1313.3.2) of the week and shall store energy to maintain timekeeping dunng power ❑ Complies The building plans and specifications include photoelectric and /or clock switches on all exterior outages lighting systems which are designed and programmed to extinguish lights when daylight i5 present, as 9 9 Y 9 P 9 9 9 P required by Section 1313 3 2 7. Connected Lighting Power (Section 1313.4) YES Complies The lighting power does not exceed the power allowance established in either the Tenant Space Method (Form 5b) or the Space -by -Space Method (Form 5c) . • L. .... • C Tenant Space Method (Form 5b) ESpace -by -Space Method (Form 5c) V2 4 I - Compliance with 2007 OSSC Form 5c Project Name. Lucy Page INTERIOR LIGHTING POWER - Space - by - Space Method Lighting Power Budget 1 Total Interior Lighting Power Budget from Worksheet 5b -1 (Sum of Column (I)) 4,849 2 Total length of track lighting (ft) 30 Track Lighting Power 3 Line 2 multiplied by 50 Watts /ft 1,500 4 Total amperage of circuit breaker(s) serving track lighting (amps) 5. Voltage of circuit breaker serving track lighting (volts) 6 Maximum wattage of track lighting (multiply line 4 by line 5) 7 VA rating of the inline current limiter or the low voltage transformers 8 Track Lighting Power (the lesser value of line 3, 6 or 7) 1,500 Building's Interior 9 Total Interior Lighting Power from Worksheet 5b -1 (Sum of Column (m)) + 2,962 Lighting Power 10 Total Adjusted Lighting Power (line 8 + line 9) - 4,462 11 Does Interior Lighting Design Meet Budget? Line 10 must be no greater than line 1 YES Exterior Canopy Parking Garage 12 Do Exterior Canopies Meet Budget (Worksheets 5c)? N/A Lighting Power 7 N/A 13 Does Parking Garage Meet Budget (Worksheets 5c) 14 Does Each Space With Retail Display Lighting Meet Budget (Worksheets 5d)? YES Retail Display Lighting Power 15 Is The Total Retail Display Lighting Additional Power Less Than 17,500 W (sum of line 9 on Worksheets 5d)? YES 16 Does Retail Display Lighting Meet Budget? YES e:o 5-3 Compliance with OSSC effecWe 01/01/05 1 Works! Project Name Lucy Page LIGHTING FIXTURE SCHEDULE (see Table 5c in instructions for default luminaire power). (a) (b) (c) (d) (e) (Q Lum Luminaire Is Luminaire ID Luminaire Lamp Ballasts Power From Type Description No Description No Description (watts) Table 5c L Track Lighting _ - -Track Lighting - -- - 50 YES A Track Lighting A Track Lighting -- -- - 50 YES K Track Lighting Track Lighting d - -- - 50 YES U Fluorescent T8 -4 fool -E 2- F32T8 /30ES LECT NO - 54W _l 2 F32T8/30ES 1 Electronic Normal Output IS 54 YES I S User Defined - 25W A -LAMP _ p - 50 NO yy 1 User Defined J Restroom - 40 NO Compact Fluorescent Triple - 2- CFTR26W /GX24 -3- ELECT -55W - 2 CFTR26W /GX24q - 1 Electronic 55 YES F Fluorescent TB - foot 1 - F32T8 /30ES - ELECT NO - 29W - 1 F32T8/30ES 1 Electronic Normal Output IS 29 YES - -1 I J _ _ A _ I I ..d f J J 1 - J A J I A J V2 4 1 - Complunco wlh 2007 OSSC • Worksheet 5b -1 Project Name Lucy Page INTERIOR LIGHTING POWER Space -by -Space Method Only Skip to column (I) d using the Tenant Space Method (a) (b) (c) (d) (e) (9) (h) (I) (1) (k) Space Type Lghhng Power Lure ID from Quantity of Lghhng Room Room ID (do not Area (Table 13 -H) Space Type Budget Worksheet 5a Luminalres (or lineal Luminaire Exempt Power (g) Total Lig leave any blanks) (ft) (enter space type only once per room) LPD (b) x (d) Column (a) ft for track lighting) Power (Watts) Fedures x (h) Power Each room Sales 2200 Retail Other Merchandise Sales Area 2 4400 R - 34 55 ❑ 1,870 3,936 moat be Elec Room 130 Electrical /Mechanical 1 5 195 U -1 4 54 ❑ 216 216 identified. Descnbo luminaires for Stockroom 258 Active Storage 0 8 200 U H 5 54 ❑ 270 270 each individual room in plans Sales Retail - Other Merchandise Sales Area 2 - S :1 9 50 ❑ 450 3,936 Resboom 60 Restrooms 0 9 54 W - j 1 40 ❑ 40 40 Sales Retail - Other Merchandise Sales Area 2 - K :1 30 50 ❑ 1,500 3,936 Sales Retail - Other Merchandise Sales Area 2 - F '1 4 29 ❑ 116 -- For track fighting enter -- - : 1 - ❑ - - lineal feet in column - - -E - - - 0 column (g) Column (k), enter sum _ __ - ❑ - - or column (1) for each room only once at first - - - :J - ❑ - -- entry for the room See ee.amplo In Instructions -- - '1 - ❑ -- -- J - ❑ - - - - :1 - ❑ - - - - A - ❑ - - -- - - - ❑ - - -- - - ❑ - - - ❑ - - - -- - ❑ - - - - _ - ❑ - - -- - ❑ - - - - - ❑ - - - - J - ❑ - -- -- - -1 - ❑ - - -- - '1 - ❑ - - -' _1 - ❑ • - -- -- - 1 - ❑ - - -- -- - ❑ - - -- -- - ❑ - - - - ❑ - - _. - ❑ - - .- _ - ❑ - -- - - - ❑ - - - -- - ❑ - - - ❑ - - -- - - ❑ - - -- - J - ❑ - - -- - J - ❑ - - - - _1 • ❑ - -- -- - J - ❑ - - 2,640 Worksheet 5b -1 Total Budget 4,849 Wkshl 5b-1 Total Lighting Power (excluding exempt/track fixtures) 2,962 Other Pages Total Number of Additional Worksheet 5b 1 0 J List the additional worksheets nets -ssary to catalog all luminaires in building (m) (n) (I) Proposed Binding Lighting Power Lighting Power Budget Space -by- (Total of column (k), excluding Area Sgft (not required for Worksheet Number Space only (Total of column (e)) exempt/track) Tenant Method) 55-1 4,849 2,962 2,640 5b -2 55 -3 Sum of addrtbnal bb worksheets � Total Budget (of all worksheets) 4,849 2,962 2,640 5 -5 V241 Can1kancowih 200/OSSC 1 • • Worksheet 5d -1 Project Name Lucy Page Retail Display Lighting Power Complete one worksheet for each room (space) for retail display lighting that is specifically directed to highlight merchandise, and is controlled separately from the general lighting system within the room. General lighting should be included on Worksheet 5b 1 Room 8 or Space ID Sales 2 Room Area (fi 2400 3. Retail Space Type Retail - Other Merchandise Sales Area (b) (c) (d) (a) Lum ID from Quantity of Lighting Worksheet 5a Luminaires (or lineal Luminaire Power (b) Describe luminaires Column (a) It for track lighting) Power (Watts) x (c) for each lndhidual L 80 50 4,000 room In plans K 3 5 50 175 For track lighting enter lineal feet In - - column (b) 1 Space Display Lighting Power (total d column excluding track fixtures) 0 2 Total length of track lighting (ft) 83 5 3 Line 2 multiplied by 50 Watts /ft 4175 4 Total amperage of circuit breaker(s) serving track lighting (amps) 5 Voltage of circuit breaker serving track lighting (volts) 6 Maximum wattage of track lighting (multiply line 4 by line 5) 7. VA rating of the inline current limiter or the low voltage transformers 8 Track Lighting Power (the lesser value of line 3, 6 or 7) 4175 9 Total Space Display Lighting Power (Watts) (line 1* line 8) 4175 10 Total Space Display Lighting Power Budget (Watts) (room area x 1 75 to max of 17,500) 4200 11 Does Space Retail Display Meet Space Budget (Line 9 less than line 10 and less than 17,500 W)7 YES V7 • � . IP CITY OF TIGARD 411,, • / 1 BUILDING DIVISION PERMIT #: 13UP2007 -00496 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 10/11/2007 Phone: (503) 639 -4171 ' :a r � /- Inspection Requests (24 Hrs.): (503) 639 -4175 " -_-. ; I 6 INSPECTION WORKSHEET FOR DATE: 3/12/2008 TIME: 7:00AM PAGE: 13 SITE ADDRESS: 09302 SW WASHINGTON SQUARE RD V05 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: LUCY DESCRIPTION: 11 OWNER: WASHINGTON SO. I_LC, PHONE #: CONTRACTOR: ELDER JONES INC • (5, PHONE #: 952 Inspection Request Scheduled For: Date: 3/12/2003 6" Pour Tim-• 6 6 Code # �spection Description Confirm # Contact # Mes :1 - qv 299 49, Final inspection 066574-01 952-297-7611 ../i Correctio i s Comments /Instructions: 3 .. (..,- A , I o f ,� 'y N iel PASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED I r Inspector: . Vi-/■ UV Dated ��I P hone #: (503) 718- Z CITY OF TIGARD -,,. I BUILDING DIVISION PERMIT #: B °UP2007 -0U496 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 10111/2007 Phone: (503) 639 -4171 V +I , Inspection Requests (24 Hrs.): (503) 639 -4175 ...' IL. INSPECTION WORKSHEET FOR DATE: 3/10/2008 TIME: 7:00AM PAGE: 8 SITE ADDRESS: 09302 SW WASHINGTON SQUARE RD V05 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: LUCY DESCRIPTION: 1 OWNER: WASHINGTON SQ. I_1 PHONE #: CONTRACTOR: ELDER JONES INC PHONE #: 952 Inspection Request Scheduled For: Date: 3/10/2008 Pour Time: Code # Inspection Description Confirm # Contact # Message 290 Final in..pection 066404 -01 952 -297 -/611 N Corrections /Comments /Instructions: 3 /11 (a) q5ke 20 d'7 - 0 4 (g3 . -'. v. -) I 3 1 (✓b) 1)6 - 005101 L 3 - 4. -4- C - 3)- Mc-. As-to '7 /I' (CJ) UtZ ix)n - Gv ( ` Cz)-4- / LA c >\ L 3/►" (G) - c r-7,6 00---) i 1 ( — rj) 3/t' (G) n,-(Z Zo 0 0 6 L i -2 ( M CcAZAAA )-- 0 , c's'j c Q *11\ G. h _ pmasto -- Rz 5,3_, . 4,, -,-ms vim. - \ A. CJ`/-- ..�i j 5 e, Sl,c.,r1( c $ Si f/AA 6,_m--. b D P ciLA Cr Z S b) e,l A-5 1\10-ti : --re4.- Ve fr\( .+ P4 . i IA (pi 6 ? (0-6) ❑ PASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS -FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: 1 /I C' Date: VLO // r Phone #: (503) 718- �1 2-ii CITY OF TIGARD BUILDING DIVISION PERMIT #: BUP2007 -00496 1 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 10i i1/2007 Phone: (503) 639 -4171 �° Inspection Requests (24 Hrs.): (503) 639 -4175 ! " - INSPECTION WORKSHEET FOR DATE: 1/16/2008 TIME: 7 :02AM PAGE: 45 SITE ADDRESS: 09307 SW WASHINGTON SQUARE RD V05 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE. LOT #: TYPE OF USE: PROJECT NAME: LUCY DESCRIPTION: TI OWNER: WASHINGTON SQ. LLC, PHONE #: CONTRACTOR: ELDER JONES INC PHONE #: 952 651 - 2851 6, Inspection Request Scheduled For: Date: 1l18f2006 Pour Time: Code # Inspection Description 'Confirm # Contact # Mess.• - 775 Framing 063503-01 952 -797 -7611 Corrections /_Comm nts /Instructions: to ' �\(2:e O-Kt) ,,, fr. 4 .64 . .• 4: ❑ PASS ARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED t i lit/1 1 bid �� '"t Ins ector: Date: Phone #: 503 Inspector: � ) 718 - CITY OF TIGARD A , BUILDING DIVISION PERMIT #: 8w-2007_0049e i 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 10/11/2007 Phone: (503) 639 -4171 lit. / Inspection Requests (24 Hrs.): (503) 639 -4175 ' x� ��;. [ INSPECTION WORKSHEET FOR DATE: 1t1012008 TIME: 7: 32AIvl PAGE: 2 SITE ADDRESS: 09302 SW WASHINGTON SQUARE RD V05 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: I_UC;Y DESCRIPTION: TI OWNER: WASHINGTON SQ. LLC, PHONE #: CONTRACTOR: ELDER JONES INC PHONE #: 952 - 854 - 2854 Inspection Request Scheduled For: Date: 1/1112008 Pour Time: Code # Inspection Descrip ion Confirm # Contact # Message 605; lit. 22-0 Slab �"" 062990-01 %2 -297 -7611 N Corrections /C m ents /Instructi ns: , f 16- 4 KSJ telL7k_ V-4-v\--ka.AL"'"-. Vpy ' (`--1,, - ,5 ..-- 4. - iM r ► / ,° f IllEgargpM C • ..3 - , 1 .� Th�Q w� - • ( ,t. ❑ PASS Wl 66-- • , - PROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: ` Date: t V b / l a Phone #: (503) 718- zy CITY OF TIGARD BUILDING DIVISION PERMIT #: L3UP2007 -00196 . 13125 SW Hall Blvd., Tigard, OR 97223 I / % ATE ISSUED: '10111/2007 Phone: (503) 639 -4171 ''�,,. Inspection Requests (24 Hrs.): (503) 639 -4175 ''I +� L r INSPECTION WORKSHEET FOR DATE: 11/16/2007 TIME: 7 :01AM PAGE: 43 SITE ADDRESS: 09302 SW WASHINGTON SQUARE RD V05 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: LUCY DESCRIPTION: Ti OWNER: WASHINGTON SO. LLC, PHONE #: CONTRACTOR: ELDER JONES INC PHONE #: 952 Inspection Request Scheduled For: Date: 11/16/2007 Pour Time: Code # Inspection Description Confirm # Contact # Message 299 Final inspection • 059807 -01 952- 297 -7611 N , i Corre tions/ omments structions: a ' -ate a � p. 11 (am) *..4 56,- ?.v ®i - ®a 53-7 _.• l.i,-e..S In, 6vy 7,007- 004(03 L ` M me' 1 3 GNI 'too - ob6 t, C 4 • %4 -' &J U t C) 246'7 - o d ( di' )-- s..41 1 1 , 01-C_ 2007 ® o — ?d - Cr ) Car MAe % A43 4-at : CkAA. AA ' 11 14 1 61/ 1 ° 0 0 4 w 4-.e 1 0197 , VIA1, 2107 -045664 -( -r ) C'■(-Q u � \ . .s (s 0, 3. A4., \al_ . • c ,i.„)_, , 6J- ,,,,-- b? A-16.44, 45:1-e-k- - alr • ASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED / 7 ---`1 12 -s, .k Inspector: 4'\ Date: 1 (/+ k P ( ° � Phone #: (503) 718- CITY OF TIGARD f M . , , ,.- BUILDING DIVISION PERMIT #: BLJP2007- 00196 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 10/11/2007 Phone: (503) 639 -4171 /s ,, p ��i�� Inspection Requests (24 Hrs.): (503) 639 -4175 INSPECTION WORKSHEET FOR DATE: 11/7/2007 TIME: 7 PAGE: 22 SITE ADDRESS: 09302 SW WASHINGTON SQUARE RD V05 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: LUCY DESCRIPTION: TI OWNER: WASHINGTON SQ. LLC, PHONE #: (2, CONTRACTOR: ELDER JONES INC PHONE #: 952 -0cf -2851 Inspection Request Scheduled For: Date: 11/7/2007 Pour Time: p Code # Inspection Descriptior+�"� Confirm # Contact # Me ge I 0 p) wag VA e7 l 059186.01 95,2- 291 -1611 Y O AI Correc-ions/ om -nts /Instructions: v �� ra A ° - s ` C \i Ze 6: 5 - 0 2 , ' ' — - 1,C206 _ 0 O'l k 1 ti 17 0 — vv t Zo d-) —6 (61r n 1 1 Zi2j,L.,,r_o\e„._; M eCil o - 6 () c ❑ PASS CiNWTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: %V Date: I ∎ / 7 / 6 7 Phone #: (503) 718- CITY OF TIGARD . . BUILDING DIVISION PERMIT #: BUP2007- 00436 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: .i0/ 11/2007 Phone: (503) 639 -4171 Inspection Requests (24 Hrs.): (503) 639 -4175 . ' °7 I — INSPECTION WORKSHEET FOR DATE: 1Q/31/2007 TIME: 7:00Am PAGE: 07 SITE ADDRESS: 09302 SW WASHINGTON SQUARE RD V05 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: LUCY DESCRIPTION: 11 OWNER: WASHINGTON SQ. LLC, PHONE #: CONTRACTOR: ELDER JONES INC PHONE #: 9,52-B51-285.4 Inspection Request Scheduled For: Date: 10/31/2007. Pour Time: Code # Inspection Description Confirm # Contact # Message 231 Suspended ceiling 058694 -01 952 -297 -7611 N Co rec . ons /Comments /Instructions: ' Jfr �✓�� - - 4(2.,05 a‘tire-tk ttp,(4101 ( • CAN-J2(. vvv - -0 0 S 0 A Aiuk. ce -Q C AN" V 4- °' ? 6 a - ° - ) �-- k ❑ PASS PARTIAL APPROVA � ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: 1 Phone #: (503) 718 - CITY OF TIGARD BUILDING DIVISION PERMIT #: P.l)P20t)7 0(496 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 10/11/2007 Phone: (503) 639 -4171 Inspection Requests (24 Hrs.): (503) 639 -4175 . ' fit INSPECTION WORKSHEET FOR DATE: 10/26/2007 TIME: 7 :00AM PAGE: 68 SITE ADDRESS: 09302 SW WASHINGTON SQUARE RD V05 CLASS OF WORK: SUBDIVISION: WASHINGTON SQUARE LOT #: TYPE OF USE: PROJECT NAME: LUCY DESCRIPTION: TI • OWNER: WASHINGTON SQ. LL.C, PHONE #: CONTRACTOR: ELDER JONES INC PHONE #: 952 - 854 -x354 Inspection Request Scheduled For: Date: 10/26/2007 Pour Time: / , t Q S (/( w`^- Code # Inspection Description Confirm # Contact # Mes : ge 275 Framing 058416 -01 952 -297 -7611 Y Corrections /Comments /Instructions: . l /z / 1— A GfuL .rJ-A Cti -t . — o'er ❑ PASS = IAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL ❑ CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: " Date: i /Z-6; d Phone #: (503) 718 - 2._ Z