Correspondence •1 • / CITY OF TIGARD Thursday, June 30, 2005 OREGON Craig D. Oka Architecture. Tel: 714- 997 -9734 1920 E. Katella Ave. Ste. S. Fax: 714 - 997 -7193 Orange, CA 92867 RE: New tenant T.I. Project Information Electrical Permit: ELC 2005 -00317 .Tenant Name: - The Cheesecake Factory - - Address: 9309 SW Washington Square Road The plan review was performed under the National Electrical Code (NEC) 2005 edition. The submitted plans are approved subject to the following conditions: r , Approved plans: One set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division electrical inspector throughout all phases of the construction. Revisions: Revisions to the approved plans shall be approved by the plan review staff of the City of Tigard prior to the inspection covering the changes. Please attach a copy of the enclosed City of Tigard, Letter of Transmittal. This will assist the City of Tigard in tracking and processing the documents Premises identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible from the street or road fronting the property. Respectfully, Herb Stabenow, Electrical Plans Examiner C: Tom Hoover GB Mannisto Inc. 1 attachment 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Friday, May 27, 2005 Crc,T D. Okfc, Stephe Heath GLP Engineering Inc. l4 rcGL% eon X 99/ l �� 1751 E. Garry Av. 101 20 l(a+ell4 A-V-SMS J jj 9 7 3 cf Santa Ana, CA 92705 0 n n 9 c 4 a in, 7 RE: New tenant T.I. Project Information Electrical Permit: ELC 2005 -00317 Tenant Name: The Cheesecake Factory Address: 9309 SW Washington Square Road The plan review was performed under the National Electrical Code (NEC) 2005 edition. The submitted plans are not approved and require the resubmission of two copies with the following changes clouded. The standards for electrical plan submissions are attached. 1. The Food service drawings and the kitchen drawings are missing. Spec. 3.08. Please submit. 2. Provide the weight of the 500 kva transformer on the mezzanine and show the structural details to support the load. In addition provide the seismic restraints for the transformer and panels "MDP" and "DP ". Permanent equipment supported by the structure, 400 lbs and over, shall have their attachments designed This requires two sets of calculations, details and material furnished and stamped by a structural engineer. IBC 1621. See attached. 3. On page E -3 note 3 shows neon equipment to be installed,by the General Contractor. The State of Oregon requires that all electrical installations are made by a State of Oregon licensed Electrical contractor. Please revise. 4. The refrigeration rack is shown on page E -2 to be fed from DB -13, but on page E -7 from DB -14. Please clarify. Z5. The bar luminaries shown in detail B on page E -6 do not comply with NEC Art. 410- 30 © for discharge lighting fixtures. Please revise. • 6 L,t1"; TIGARD Approved ................................................. l• Condtktonally Appmv2d. . ........................... o. onl•i the Ort.: 3S dC5Cribed 0- NIT NO._ Lvf,Icir zo.Volvyo ....... . ..... .• . . 14:-.acn ..• ..• ......... ..... Job 0 a'. • • • Page 2 Stephen D. Heath 6. The 125 V outlets in commercial kitchens that are used for food preparations are to be GFCI protected. NEC 210.8 This applies to the wall receptacles as well as the cord drops in rooms 135 prep kitchen, 111 main cooking and room 103 the bakery. Please revise the plans accordingly. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfully, Herb Stabenow, Electrical Plans Examiner C: Craig D. Oka Architecture 3 attachments GLP Engineering, Inc. Mechanical and Electrical Engineers MEMO Page 1 of 1 DATE: August 30, 2005 TO: The City of Tigard FROM: Jon Dickinson FILE COPY PROJECT: The Cheesecake Factory- Tigard Vof 04 (mac 20_5=0 ' We take no exception to the use of MC cable installed in concealed spaces and/or walls, as is allowed by Article 330 of the National Electrical Code. If you have any questions or would like to discuss this, please do not hesitate to call. A sI, PR 44 GINEF W 1 ir OREGON 1 ��s &k. 12'3 P: \Clients \Cheesecake \Tigard, OR 125.075\Documents\8 -30 -05 MC CABLE MEMO - revised.doc 1751 E. Garry Avenue • Santa Ana, CA 92705 -5814 Phone: 949 - 428 -8800 • Fax: 949 - 428 -8805 • www.glpk.com