Loading...
Plans qCi Octiok Gq5: oof ti r P ao o�i, o 5(03 COOPER Wheelock Series E50 Speaker and Speaker Strobes - R SERIES E50 SERIES E50 Speaker Strobe Speaker Description Features The Wheelock Series E50 Speakers and Speaker Strobes feature • Approvals include: UL Standard 1971, UL Standard 1480, New high efficiency sound output, with dual voltage (25/70 VRMS) York City (MEA), California State Fire Marshal (CSFM), Factory capability and field selectable taps from 1/8 to 2 watts. They are Mutual (FM) and Chicago (BFP). See approvals by model in designed to provide a sleek, aesthetic appearance for emergency Specifications and Ordering Information voice /alarm communications systems. All Series E50 models ADA/NFPA/ANSI compliant • mount to standard 4" x 2 -1/8" electncal boxes (with no extension ring required) and incorporate a speaker mounting plate for faster • Complies with OSHA 29 Part 1910.165 installation. The grille cover snaps on so no mounting screws are Wall mount speaker strobe models with field selectable candela visible. Attractive surface boxes are also available for surface settings of 15/30/75/110cd or 135/185cd (Multi - Candela installations. models), or 1575cd (Single Candela model) The Series E50 Speaker Strobe models use Wheelock low current • Field selectable taps for 25 or 70 VRMS operation from 1/8 watt draw Series RSS strobes for wall mounted applications Strobe up to 2 watts options include patented MCW multi- candela strobes with field selectable candela settings of 15/30/75/110 cd or high intensity • High efficiency design for maximum output at minimum wattage MCWH strobes with field selectable 135 /185 candela. Models with across a frequency range of 400 to 4000 HZ 1575 candela (75 cd on axis) are also offered. 24 VDC strobes produce 1 flash per second with wide UL Series E50 Speakers and Speaker Strobes provide high audio output "Regulated Voltage" of 16 to 33 volts using filtered DC or with dear audibility and are designed to meet the critical needs of the unfiltered VRMS input voltage life safety industry for effective emergency voice communications, Synchronize with Wheelock SM, DSM or Wheelock tone signaling and visible signaling to alert the hearing impaired. PS- 12/24 -8CP and PS- 12/24 -8MP Power Supply with built -in The strobe portion of all Series E Speaker Strobes may be sync protocol synchronized when used in conjunction with the Wheelock SM, Mount to 4" square x 2 -1/8" deep backbox with no extension DSM Sync Modules or the Wheelock's PS- 24-8MC Power Supply ring required with Patented Sync Protocol. Wheelock synchronized strobes offer an easy way to comply with ADA and NFPA regulations concerning • Snap on grille cover with no visible mounting screws photosensitive epilepsy. • Fast installation with IN /OUT screw terminals using #12 to #18 Series E50 Speaker Strobes are UL Listed for indoor use under AWG wires Standard 1971 (Signaling Devices for the Hearing - Impaired) and Standard 1480 (Speaker Appliances). All inputs employ IN /OUT wiring terminals for fast installation using #12 to #18 AWG wiring and are compatible with FACP line supervision. Color options for the Series E50 Speakers and Speaker Strobes are red or off-white ,,,z,,; „ MEA I' i APPROVED - - S5391 151 -92 -E 7125-0785 165 7320 -0785 166 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range. Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93% (± 2%). • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range ". Table 1: Average RMS Current * RMS current ratings are per UL average RMS E50 Strobe Current -Wall Mount method. UL max current rating is the maximum E50 RMS current within the listed voltage range (16 -33v Speaker 241575W 24MCW 24MCWH for 24v units). For strobes the UL max current is Strobes 1575cd 15cd 30cd 75cd 110cd 135cd 185cd usually at the minimum listed voltage (16v for 24v 24 vdc 0.060 0.041 0.063 0.109 0.140 0.195 0.270 units). For unfiltered FWR ratings, see installation instructions. UL max* 0.090 0.060 0.092 0.165 0.220 0.300 0.420 Table 2: E50 UL Reverberant dBA @ 10 Feet ** watts 1/8 1/4 1/2 1 2 E50 Speaker 77 79.5 82.5 85 88 E50 Speaker Strobe 77 79.5 82.5 85 88 *'dBA ratings are based on UL testing under UL Standard 1480 • Wiring Diagrams" SERIES E50 SPEAKER & STROBE OPERATE SERIES E50 SPEAKER STROBES SYNCHRONIZED INDEPENDENTLY (NON -SYNC OR SYNC) WITH MULTIPLE DSM MODULES FROM 1/1 PRECEDING + ± 10 NEXT OR VOILE - APPI IAN( f Strube NAC CiI . 0 + D� M F EVACIIA I ION PANEI. I DSM N2 Note Figure shows I RUM + - — 1 r — — — — — — + ID NLMI A Su„bk NAC Cl ®tiMar Interconnection to PRECEDING 1 r SI ROBE OR � i� strobe through sync STROVE - - - — — — — - GOER SYNC MODULE 1 1 r DSM 43 module. Speaker POW1R SUPPLY P S portion requires 2 % �/ OR LACP sul,h.' NAC Cl ` y , r I�MEN separate conductors 0 U % r - to communications DSM Interconnecting wiring shown. Maximum of system STROBE SPEAKER twenty (20) SERIES E50 SPEAKER STROBE APPLIANCES SERIES E50 SPEAKER STROBE APPLIANCES & RSS SYNCHRONIZED WITH DSM MODULE SINGLE STROBES SYNCHRONIZED WITH PS- 12/24 -8CP and CLASS "A" DSM PS- 12/24 -8MP Seiles PS- 12/24 -8MP of PS- 12/24 -8CP STROBE * 0 _- NAC SYNC CIRCUIT - 0 E50 I, OUT I , `OUT 1 OUTPUTS 01, EOLR I CP . IN I m®3®i®r F 14 O 4 -CLASS I/ MINUS I A L � . OR O I� AUDIBL• C 2 -CLASS < 0 MINUS 2 A J P O . IN 2 ®�eso .' tso , STROBE I, , OUT 2 � NAC CIRCUIT Seis es PS 12/24 - 8MF 01 PS -12/24 -8CP Specifications and Ordering Information Surface Agency Approvals Order Wall Ceiling Strobe Grill Flush Mount Mounting 9 Y pp Model Code Mount Mount Candela Color Bacbox gM kbox Options UL MEA CSFM FM BFP E50 -R 0222 X X - Red 4' x 4" x 2 -1/8" E5OSB -R E,O,P,Q,R,U,Y,AA X * X X * E50 -W 0223 X X - White 4' x 4" x 2 -1/8" E5OSB -W E,O,P,Q,R,U,Y,AA X • X X • E50- 241575W -FR 0224 X - 15 (75 on Axis) Red 4' x 4" x 2 -1/8" E5OSSB -R E,Q,U,BB X • X X E50- 241575W -FW 0225 X - 15 (75 on Axis) White 4' x 4" x 2 -1/8" E50 -SSB -W E,Q,U,BB X * X X * E50- 24MCW -FR 0226 X - 15/30/75/110 Red 4' x 4" x 2 -1/8" E5OSSB -R E,Q,U,BB X * X X * E50- 24MCW -FW 0227 X - 15/30/75/110 White 4' x 4" x 2 -1/8" E50 -SSB -W E,Q,U,BB X * X X * E50- 24MCWH -FR 0228 X - 135/185 Red 4' x 4" x 2 -1/8" E5OSSB -R E,Q,U,BB X • X X • E50- 24MCWH -FW 0229 X - 135/185 White 4' x 4" x 2 -1/8" E50 -SSB -W E,Q,U,BB X • X X * * PENDING NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock Inc. standard terms and conditions. Architects and Engineers Specifications The speaker appliances shall be Wheelock Series E50 Speakers and the speaker strobe appliances shall be Wheelock Series E50 Speaker Strobes or approved equals. The speakers shall be UL Listed under Standard 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices for the Hearing- Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class B. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts All models shall have listed sound output of up to 89 dBA at 10 feet and a listed frequency response of 400 to 4000 Hz The speaker shall incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall be of low current design. Where Multi - Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mounting. The selector switch for selecting the candela shall be tamper resistant The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required. When synchronization is required, the strobe portion of the appliance shall be compatible with the Wheelock's SM, DSM sync modules or Wheelock PS- 24 -8MC Power Supply with built -in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor flush mounting to 4" x 2 -1/8" electrical boxes without need for an extension nng or surface mounting to Wheelock's E5OSB or E5OSSB surface boxes. The speaker and speaker strobe shall incorporate a speaker mounting plate with a snap -on grille cover. The finish of the Series E50 speakers and speakers strobes shall be white or red. COOPER Wheelock 273 Branchport Avenue EM Long Branch, NJ 07740 Phone (800) 631 -2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax (732) 222 -2588 3 YEAR WARRANTY www cooperwheelock.com Made in USA S0510 E50 06/06 COOPER Wheelock Series RSS and RSSP Strobes and Strobe Plates J F FIRE " FIRE' IR E '`` }'s FIRE , FIRE .. Series RSS Series RSS Series RSSWP RSS Round Description Features • The Wheelock patented Series RSS Strobe Appliances and Approvals include: UL Standard 1971, New York City (MEA), Series RSSP Strobe Plates have lower current draw while California State Fire Marshal (CSFM), Factory Mutual (FM), and maintaining outstanding performance, reliability and cost Chicago (BFP) See approvals by model in Specifications and effectiveness These versatile appliances will satisfy virtually all Ordering Information requirements for indoor, wall or ceiling mount applications • ADA/NFPA /UFC /ANSI compliant Meets OSHA 29 Part Strobe options for wall mount models include 1575 or the 1910.165 Wheelock Patented MCW multi - candela strobe with field • Wall mount Multi - Candela models are available with Field selectable candela settings of 15/30/75/110cd or the high Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd intensity MCWH strobe with field selectable 135/185cd. Single Candela models are available in 1575cd Ceiling mount models include the patented MCC multi - candela Ceiling mount Multi - Candela models are • ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable available with field selectable candela settings of 15/30/75/95cd 115/177cd. or 115/177cd. (Round or Square) All models may be synchronized using the Wheelock SM, • Strobes produce 1 flash per second over the DSM Sync Modules or the PS- 24 -8MC Power Supplies with regulated voltage range the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes • 12 and 24 VDC models with wide UL "Regulated Voltage" us- in the field of view. Wheelock's synchronized strobes offer an ing filtered (DC) or unfiltered VRMS input voltage easy way to comply with ADA recommendations concerning • Synchronize using the Wheelock sync modules or power sup - photosensitive epilepsy as well as meeting the requirements plies with built -in sync protocol of NFPA 72. • Fast installation with IN /OUT screw terminals using #12 to #18 The Wheelock Series RSS Strobes employ a Patented Integral AWG wire Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification For Weatherproof Series RSS See Datatsheet S9004 Appliance Trimplate) may be used It provides an additional 65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi- Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox .7:A 0 i ld i Do . • MEA ►" APPROVED S5391 151 -92 -E 7125- 0785 141 7300 -0785 154 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range ". Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93% (± 2 %) • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range ". Table 1: Average RMS Current* RSS /RSSP - Wall Mount Ceiling Mount RSS /RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC - Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd UL max' 0.090 0 060 0.092 0.165 0.220 0.300 0.420 0 065 0.105 0.189 0.249 0 300 0.420 RSS /RSSP RSS /RSSP 24VDC Wall Mount Models * RMS current ratings are per UL average RMS method. UL max current 121575W rating is the maximum RMS current within the listed voltage range (16 -33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at UL max* 0.255 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Table 2: Audibles /Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Wiring Diagrams # SERIES RSS /RSSP APPLIANCE Horns AH, NH, HS Motor Bells MB- G6 /G10 FROMC. + +, TO NEXTE Speakers ET- 1010/1080, E70, ET70 PRECEDING:] _ _ ;PPLIANCELI 111 11 APPLIANCE, SYNC? OR EOLRLJ Chimes CH70 MODULE, POWERO SUPPLY OR FACPD d SERIES RSS /RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT SERIES RSS /RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES DSM #11_7 DSM sync /N STROBE' 0 Strobe NAG C1ir 0 }7 �- NACI'I SYNC 0 F� — - CIRCUIT • L Gi p DSM #211 i �i " Strobe NAG CI � +L / ORM / !`I `IJS 1 0 — DSM #3, I Cl ni:ms z PEI S, nc] ME � ®II ® Strobe NAC C_r` ±' STROBE// SAC CIRCUIT[/ DSM Interconnecting wiring shown. Maximum of RETURNC' twenty (20)L - STROBE/PLATE ASSEMBLY AUDIBLE 8 VISIBLE APPLIANCE OPERATE IN UNISON SERIES RSS /RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT TO NEXTH S M❑ FROM APPLIANCE_ �❑ _ 0 ._STROBE_ PRECEDING__ ± ± OR EOLR - STROBE' APPLIANCE, SYNCI T I � Strobe ty E-. ri t.c gel MODULE, POWER ! ucuJt SUPPLY OR FACPI 0 +I rL . CC Hudib e STPOBEO AUDrBLEf_' PD COLR. ; - Audib STROBE /PLATE ASSEMBLY SERIES RSS /RSSP APPLIANCES SYNCHRONIZED AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY WITH PS - 12/24 - 8CP or PS- 12/24 -8MP t - +0 +q , Series PS- 12 /24 -8MP■ I ASO+ OUTPUTS., v EOLPG -4^ + 4- CLASS: I ASC 11<1 411 ELI A 2 -GETS SC +o-n-. +D-■ P_ STROBEJ APPLIANCE❑ ASO " For detail using SM or DSM Sync Module refer to Data Se_ les PS- 12/24 -8t Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS- 12/24 -8CP and P84333 for PS- 12/24 -8MP. Specifications and Ordering Information Order Wall Ceiling Non- Strobe 24 12 Color Color Square Agency Approvals Model Code Mount Mount Sync Candela VDC VDC RED WHITE Mounting Options "` or y Round UL MEA CSFM FM BFP RSS - 24MCW -FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS - 24MCW -FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 241575W -FR 7471 X - X 15 (75 on Axis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 241575W -FW 7788 X - X 15 (75 on Axis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 121575W -FR 7476 X - X 15 (75 on Axis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 121575W -FW 7468 X - X 15 (75 on Axis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS - 24MCC -FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSS - 24MCC -FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSS- 24MCCR -FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X • RSS- 24MCCH -FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSS- 24MCCHR -FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X • RSS- 24MCWH -FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X ` RSS- 24MCWH -FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSSWP- 2475W -FR" 9013 X - X 180@ 77 °F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X • 75@ -31°F RSSWP - 2475W -FW• 3034 X - X 180@ 77 °F X X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X • 75@ -31 °F RSSP- 121575W -FR 7798 X - X 15 (75 on Axis) - X X - D,E,Z Square X X X X X RSSP - 24MCW -FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP- 241575W -FR 7793 X - X 15 (75 on Axis) - - X - D,E,Z Square X X X X X *PENDING All models sync with Wheelock SM, DSM or PS- 12/24 -8CP or PS- 12/24 -8MP # Models are available in either Red or White Call Customer Service for Order Code & Delivery **For Weatherproof Series RSS Strobe specifications see data sheet S9004 • "`Refer to data sheet S7000 for mounting options. Architects and Engineers Specifications - The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing - Impaired) for Indoor Fire Protection Service The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS The Series RSS Strobe shall be of low current design. Where Multi - Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount The selector switch for selecting the candela shall be tamper resistant The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g ADA compliance) When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or the Wheelock PS -24- 8MC Power Supplies with built -in Patented Sync Protocol The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single - gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided An attaching cover plate shall be provided to give the Appliance and attractive appearance The Appliance shall not have any mounting holes or screw heads visible when the installation is completed The Series RSSP Multi- Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting All notification appliances shall be backward compatible. NOTE Due to continuous development of our products specifications and offerings are subject to change without notice in accordance with Wheelock, Inc standard terms and conditions COOPER Wheelock 273 Branchport Avenue Er b Long Branch, NJ 07740 Phone (800) 631 -2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732) 222 -2588 3 YEAR WARRANTY www cooperwheelock com Made in USA SO410 RSS /RSSP 07/07