Correspondence City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223
•
November 21 2006
T IrGAR,
William Polk
1120 Post Alley
Seattle, WA 98101
RE: STOCK ROOM - REVIEW
Project Information
Building Permit. BUP2006 -00552 Construction Type: II B
Tenant Name: Macy's Occupancy Type: S1 — 2 story
Address: 9300 SW Washington Sq Occupant Load: 56
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition;
anii 2004 International Fire Code as amended by TVF&R. The submitted plans are approved subject to
the following conditions.
1. Special inspection is required for welding, embed plates, bolts in concrete, structural steel
fabrication and erection, adhesive and expansion anchor installation. The special inspection
agency of record shall furnish inspection reports to the Engineer of Record, Collons and Smith
Engineers, Inc. , the General Contractor, and the City of Tigard, Building Division, attention Hap
Watkins. All discrepancies shall be brought to the immediate attention of the general contractor for
correction. The special inspector shall submit a final signed report stating whether the work requiring
special inspection was, to the best of the inspector's knowledge, in conformance with the approved
plans and specifications and the applicable workmanship provisions of the code. 1704, 1705, 1707, 1708
OSSC FYI The special inspections do not waive the any of the inspection required by code.
2. The live loads for which each floor has been designed to exceed 50 psf shall be conspicuously posted by
the owner in that part of each story in which they apply, using durable metal signs, and it shall be
unlawful to remove or deface such notices. The occupant of the building shall be responsible for
keeping the actual load below the allowable limits. 1603.3 OSSC
3. Provide 2 -A rated fire extinguishers in the new area. The extinguishers shall be located so that no usable
• space has a distance greater than 75 feet to the extinguisher. OFC 906.3
4. Horizontal sliding or vertical security grilles shall be openable from the inside without the use of a key
or special knowledge or effort during periods that the space is occupied. OSSC 1008.1.3.5
5. All exit doors shall be openable from the inside without the use of a key or any special knowledge or
effort. OSSC 1008.1.8
Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772
6. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of
egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the
path of egress travel is not immediately visible to the occupants. Sec. 1011.1
7. Where not all means of egress are accessible, directional signs shall be provided at nonaccessible
exits to indicate the route to the nearest accessible exit or area of rescue assistance, as required in
Sections 1108.4.12, 1109.15.2, 1109.15.3 and 1109.15.4. OSSC 1107.5
8. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level
any the building is occupied. The means of egress illumination shall be provided with a second
source of power in case of primary power loss. 1006. OSSC
9. The power supply for means of egress illumination shall normally be provided by the premise's electrical
supply. In the event of power supply failure, an emergency electrical system shall automatically
illuminate the following areas:
1. Exit access corridors, passageways and aisles in rooms and spaces which require two
or more means of egress.
2. Exit access corridors and exit stairways located in buildings required to have two or
more exits.
3. Exterior egress components at other than the level of exit discharge until exit
discharge is accomplished for buildings required to have two or more exits.
4. Interior exit discharge elements, as permitted in Section 1023.1, in buildings required
to have two or more exits.
5. The portion of the exterior exit discharge immediately adjacent to exit discharge
doorways in buildings required to have two or more exits.
6. The emergency power system shall provide power for a duration of not less than 90
minutes and shall consist of storage batteries, unit equipment or an on -site generator.
The installation of the emergency power system shall be in accordance with Electrical Code.
10. Deferred submittals such as Truss Joist Shop Drawings, suspended ceiling system etc, will be charged a
deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum
fee shall be $200.00. This fee is in addition to the project plan review fee based on the total project
value. OAR 918- 050 -0150 Deferred Items: Prefabricated stairs
"Documents for deferred submittal items shall be submitted to the registered design professional in responsible charge
who shall review them and forward them to the building official with a notation indicating that the deferred submittal
documents have been reviewed and been found to be in general conformance to the design of the building. The deferred
submittal items shall not be installed until the design and submittal documents have been approved by the building
officiaL Oregon Structural Specialty Code Section 106.3.4.2"
NOT PART OF THIS REVIEW:
* Electrical * Fire Sprinklers * Racks
* Mechanical System * Plumbing
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained
on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of
construction. 106.3.1 OSSC
Certificate of Occupancy: No building or structure shall be used or occupied until the Building Official
has issued a certificate of occupancy 110.1 OSSC
Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such
a position as to be plainly visible and legible from the street or road fronting the property.
When submitting revised drawings or additional information, please attach a copy of the enclosed City of
Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and
processing the documents.
Respectful)
Val Henzel
Senior Plans Examiner