Loading...
Specifications Co (7 s..,. i,J 0,...ey,,.," a t- • :. •, . ;•P ! US •; k. ; • , M WAIIIII 3 y; �, .r� LPCB ti.. , a P a o � ' c� �� ® ® ®i i VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Standard Spray /Pendent, Upright and Recessed Pendent MODELS V3401, V3402, V3405 AND V3406 STANDARD AND QUICK RESPONSE These Model V34 standard spray sprinklers are designed to produce large discharge capacity ir , Ti , in a hemispherical pattern standard in commercial applications The design incorporates a state -of- the -art, heat responsive, frangible glass bulb design (standard or quick response) for — , -- prompt, precise operation RECESSED PENDENT PENDENT The die cast frame is more streamlined and attractive than traditional sand cast frames It (V3405 AND V3406) (V3405 AND V3406) is cast with a hex - shaped wrench boss to allow easy tightening from many angles, reducing .. assembly effort. This sprinkler is available in various temperature ratings (see chart on page 2) and finishes to meet many design requirements , je, The recessed pendent should be utilized with a Model V34 recessed escutcheon which provides up to 3 A719mm of adjustments. Sprinkler Operation R ' , � 1D The operating mechanism is a frangible glass bulb which contains a heat responsive liquid RG` ' °�� During a fire, the ambient temperature rises causing the liquid in the bulb to expand When (V3401 AND V3402) the ambient temperature reaches the rated temperature of the sprinkler, the bulb shatters. JUN 2 Z � )� As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effective in C ®F G ID controlling the fire. BUILDING DnrQ -, � ) Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. Agency Note: Upright models V3401 and V3402 not VNIIPO approved TECHNICAL SPECIFICATIONS Models: V3401, V3402, V3405, V3406 Accessories Style: Pendent, Upright or Recessed Pendent Installation Wrench: Nominal Orifice Size: , 7A2 /14mm • Open End: V34 . B K- Factor: 8.OImp. /11.5S.1 A • Recessed: V34 Nominal Thread Size: 3/4" NPT /20mm Sprinkler Finishes: Max. Working Pressure: 175 psi /1200kPa • Plain brass Factory Hydrostatic Test: • Chrome plated 100% @ 500 psi/3450 kPa • White painted ** 7 Min. Operating Pressure: 7psi /48kPa Flat black painted ** • Temperature Ratings: See chart on page 2 • Custom painted ** • Lead Material Specifications • Proprietary Nickel Teflon* coating ** ,�� , Upright Deflector: Bronze per UNS C22000 155, 200, 286SR Only: lvili h Pendent Deflector: Bronze per UNS C51000 • Wax I Bulb: Glass with glycerin solution • Wax over lead B ulb Nominal Diameter: For cabinets and other accessories refer to 1 Standard: 5.0 mm separate sheet. • Quick Response: 3.0mm NOTE: Weather resistant recessed escutcheons Load Screw: Bronze per UNS C65100 available upon request. Pip Cap: Bronze per UNS C65100 Seal: Teflon* tape A For K-Factor when pressure is measured in �•� Spring: Beryllium nickel Bar, multiply S.I units by 10.0 Frame: Die cast brass 65 -30 * Teflon is a registered trademark of Dupont Co Lodgement Spring: * *Also, UL Listed for corrosion resistance Stainless steel per UNS S30200 Exaggerated for clarity OFFICE COPY 111M4WW JOB /OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com jctaulacr' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 4U.1 b V< , K ° t Standard Spray /Pendent, Upright and Recessed Pendent MODELS V34O1, V34O2, V34O5 AND V34O6 STANDARD AND QUICK RESPONSE . 'APPROVALS /LISTINGS' .. r M Orifice Size`(inch`es) - ' 17/32" ' 17/32" 17/32" 17/32" 17/32" 17/32" 17/32" Orifice Size (mm) • ' ' 14 14 14 14 14 14 14 - Nominal K• Factorlmperlal '' 8 0 8 0 8 0 8_0 8 0 8 0 8 0 Nom 5 inal K Factor'S.I.^ 11 5 11 5 _ �� 11 5 11 _ �11 5 11 5 11 5 _ Response Standard Standard Standard Quick Quick Quick Quick Deflector Type Recessed V Recessed Recessed le Y p " Upright Pendent pendent Upright Pendent pendent Pendent Adjustment up to' /" up to 3/4" Approved Temperature Ratings MC' by Agencyt . . Model - - 135 °F /57 °C ' 1350F/57°C 135 °F /57 °C 35 °F /57 °C 135 °F /57 °C 155 °F /68 °C 155 °F /68 °C 155 155.F/68°C 155 135 °F /57 °C 135 °F /57 °C UL 175 °F /79 °C 175 °F /79 °C 175 °F /79 °C , 175 °F /79 °C 175 °F /79 °C 175 175 °F /79 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93°C 286 286 °F /141 °C 286 °F /14.1 °C , 286 °F /141 °C 286 °F /141 °C 360 °F /182 °C 360 °F /182 °C , 135 °F /57 °C 135 °F /57 °C 135 °F /57 °C 135 °F /57 °C 135 °F /57 °C 55 °F /68 °C 55 °F /68 °C 155 °F /68 °C 155 °F /68 °C 155°F/68°C 135 °F /57 °C 135 °F /57 °C ULC 75 °F /79 °C 1750F/79°C 175 °F /79 °C 175 °F /79 °C 175.F/79°C 175°F/79 °C 175 °F /79°C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 1 200 °F /93 °C 2000F/93°C 200 °F /93 °C 200 °F /93 °C 286 286 °F /141 °C 286 , 286 °F /141 °C 286°F /141 °C 360 °F /182 °C 360 °F /182 °C 135 135 °F /57 °C 735 °F /57 °C 135 155 °F /68 °C 155 °F /68 °C 135 °F /57 °C 155 °F /68 °C 155 °F /68 °C 135 °F /57 °C FM 175 175.7/79°C 175 °F /79 °C 175 °F /79 °C 175.F/79°C 175.F/79°C None 200 °F /93 °C 200 °F /93 °C 200 200 200 °F /93°C 200 °F /93 °C i 286 °F /141 °C , 286 286.F/141°C 286 °F /141 °C ' ' 'I 360 360 °F /182 °C ' 135 " 135 °F /57 °C 135 °F /57 °C� 135°F/57°C 135 °F /57°C . 155.F/68°C 155 °F /68 °C 155 € 155 °F /68 °C 155 135 135 °F /57 °C NYC /MEA # 62.99 -E' 175 °F /79 °C 75 °F /79 °C 175 175 175 175 °F /79 °C 175 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 200 °F /93 °C 200 286 2860F/141°C 286 °F /141 °C ` 286 286 360 360 " 135 °F /57 °C 135 °F /57 °C 135°F/57°C 135 135 °F /57 °C 155 °F /68 °C 1550F/68°C 155 °F /68 °C 155 °F /68 °C 155 °F /68 °C 135 °F /57°C 135 °F /57 °C CSFM # 7690 - 0531:112 175 °F /79 °C 175 °F /79 0C 175 °F /79 °C ; 175 °F /79 °C 175°F/79 °C 175 °F /79 °C 175 °F /79 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 286 °F /141 °C 286 °F /141 °C 286 0 F /141 > 286 286 . " ' , 360 360 135 °F /57 °C 135 °F /57 °C 155 °F /68 °C 135 °F /57 °C 155 °F /68 °C 135 °F /57 °C VNIIPO' 175 °F /79 °C None 175 None 175 " 175 °F /79 °C None 200 °F /93 °C 200°F/93 °C 200 200 °F /93 °C 286 °F /t41 °C 286 °F /141 0C , 360 t Listings and Approvals of printing All are approved open, except for areas designated "No' ^ For K Factor when pressure is measured in Bar, multiply S I units by 100 - . a I 11 ? :ti`2i ij ' I lu, VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED �C.t`dUIIC' FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40 . V34. K8.0 Standard Spray/Pendent, Upright and Recessed Pendent MODELS V3401, V3402, V3405 AND V3406 STANDARD AND QUICK RESPONSE RATINGS All glass bulbs are rated for temperatures from -65°F/-54°C to those shown in table below. Victaulic , Sprinkler Temperature ' Part Nominal Temperature Maximum Ambient Classification - Identification Rating Temperature Allowed Glass Bulb Color 135 Ordinar 100 y' A Orange 57 38 _ 155 100 Ordinary C Red 68 38 Intermediate E 175 165 50 Yellow 79 200 150 ' Intermediate, F 65 Green 93 286 225— High Blue 141 107 360 300 Extra High K Mauve M 182 149 1 Open No Bulb Standard response only All are approved open, except for areas designated "No" — 150/65 if wax coated ORDERING INFORMATION Please specify the following when ordering- Sprinkler Model Number; Style Temperature Ratihg , ...„ . K-Factor Thread Size Sprinkler Finish Escutcheon Finish, Wrench Model Number www.victaulic.com Njicitaufie VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED. FIRE PRO t ECTION PRODUCTS - /AUTOMATIC SPRI�J }t!- ls5 4U. 1 b Standard Spray /Pendent, Upright and Recessed Pendent MODELS V3401, V3402, V3405 AND V3406 STANDARD AND QUICK RESPONSE WARNING A _ A WARNING • Always read and understand installation, care and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. ' • Always wear safety glasses and foot protection. , • Depressurize and drain the piping system before attempting to install, remove or adjust any Victaulic piping products. • Installation rules, especially those governing obstruction, must be strictly followed. • Painting, plating or any re- coating of sprinklers (other than that 0 supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and /or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler _ systems. In addition, the authority having jurisdiction may have additional Prillidhig maintenance, testing and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044 -0031 USA, Telephone: 001 - 610 - 559 -3300. DIMENSIONS Standard Pendent — V3405, V3406 Standard Upright — V3401, V3402 t L l 64 mm 45 mm/ 1 4II 46 mm lair 64 mm/ i 2h I I f 1 W ! a 33 mm 1/2" Adjustment Recessed — V3405, V3406 (drawing not to scale) 2 5"/60 mm Max Hole 2/51 mm Min Hole 1 ltiligl f - IM "/ 18 mm 16 mm / / I I I� � Typical Ceiling The ��I ® � fm I ' %Y 11 I�� Finished Surface 4:, 34 mm 47 mm V 1 MAXIMUM RECESS 2 %775 mm MAXIMUM EXTENSION ✓ctalullct VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED FIRE PROTECTION ION PRODU -- AUTOMATIC SPRINKLERS 4U. 1. W \, r , ° G ^ Standard Spray /Pendent, Upright and Recessed Pendent MODELS V3401, V3402, V3405 AND V3406 STANDARD AND QUICK RESPONSE DIMENSIONS 3 /4" Adjustment Recessed — V3405, V3406 (drawing not to scale) 2't "/60 mm Max Hole —.' 2 "/51 mm Mm Hole l�aii 1 W"/ "As "/ �••/ /v��rr� 35 mm 24; m 16 m ���u Typical veiling Tile ��'�'��'�m I ' 1 ,. , 116 " / IW/ NTO finished Surface 29 47 mm I MAXIMUM RECESS 2'31 /75 mm MAXIMUM EXTENSION AVAILABLE WRENCHES Sprinkler Type V34 Recessed V34 Open End f ' V3401, V402 Upright yes yes V3405, V3406 Pendent yes yes V3405, V3406 Recessed Pendent yes — DISTRIBUTION PATTERNS Models V3405, V3406 K8.0 standard pendent and recessed pendent distribution patterns — trajectory la t g •1.. i•.... 1 _ ? ( 1 - s � a tt i 1 - 8' 1 ' �•• L.... ., e..1....__... - 1 _ �. ... 2 4m ! _ ._.. .. I __ �..�. -._. 1 I 1 4 i, � . --_._. _., - ._..... _.- ..._. I _.�.. ....� `_.._�......�� e _ � .�----- __....` : ..r _� .. a �� 144 �_ • i ♦ i 1 I € r _ _ _�_— ! . .� -__ —I l __ _° ,, _ -' - . = . I j , .. _ `., ' - I � I q ' 4 1 4 • € i r i 1 ..,,,.. ,._ € .... { .._ € ...._. � L�,.,. , .._..... 1 .......,, `• ,''• 1 0 6m 1 t 4 s 1 t ; s� , 2' 4' 6' 8' 10' 12' 14' 16' 06m 1 2m 1 8m 24m 30m 37m 4 3m 49m 7psi ∎ "•■■"' 15 psi 30 psi 48 kPa 103 kPa 207 kPa Refer to notes on page 6. www.victaulic.com ICta! !1G' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40 . 1 J V34 . . Standard Spray /Pendent, Upright and Recessed Pendent MODELS V3401, V3402, V3405 AND V3406 STANDARD AND QUICK RESPONSE DISTRIBUTION PATTERNS Models V3401, V3402 K8.0 standard upright distribution patterns — trajectory 30m 10' . 'Ti �. ' % - f __o n , -- — e m • � 2 4m '.4 ... j e _ 1. •" � _ a ,.y... .. _ i .e .,1 ..e ... e, .. .a 18m - I 1 ; . ... • N ''N 4 '�� N I ! , .......,, _ d _ _ . ,._. _.�, - --- ' ., ._ f - ,µ,,.. — •�.....w., 7 � -%. .�..... I ...,. M _ _ . } 0 6m � � i 1 _ ° ___ 33 c � ...._.. _. I ., �� 1 s .,[..__ _. _. ,,s... _ _ -__! __ _ 2 i `� �: '` L ti i zxiix ( ,6 1 I E € i • 06m 12m 1.8m 24m 30m 37m 43m 49m 2' 4' 6' 8' 10' 12' 14' 16' 48kPa ®•' ®°• 103 kPa 207kPa 7 psi 15 psi 30 psi NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, floor - wetting and wall - wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED �CtaUIIe FIRE PROTECTION PRODUCTS — AUTOMATIC SPRINKLERS 4U. 1 d 1 13A K80 9 . Standard Spray /Pendent, Upright and Recessed Pendent MODELS V3401, V3402, V3405 AND V3406 STANDARD AND QUICK RESPONSE WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications All products to be installed in accordance with current Victaulic installation /assembly instructions Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations www.victaulic.com jctaulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED : ': •► ':11 •IIL ': ►, : tw itel=1•111 „ l r t, Standard Spray /Pendent, Upright and Recessed Pendent MODELS V3401, V3402, V3405 AND V3406 STANDARD AND QUICK RESPONSE III IIIIIIIIIIII111111111III11IIIIIIIIII IIII WCAS- 7AVN44 For complete contact Information, visit www.victaulic corn 40.15 2547 REV G UPDATED 01/2008 ictaauli VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED • G• . •L •• ; •u: ••: ►.. ; A �� �'� 1 P // , r� _ ( ' ® FM ® (LPCBI � 1 �� fl I""� c1,1 VNIIPD SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Standard Spray; Upright, Pendent and Recessed Pendent MODELS /S.I.N. V2703 AND V2707 STANDARD RESPONSE i� - i — 0 4 yK MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE [ . a_3- lit These Model V27 standard spray sprinklers are designed to produce a i d . hemispherical spray pattern for standard commercial applications They are ' available with either standard or quick response bulbs. The design incorporates k' +•• t ' state -of- the -art, heat responsive, frangible glass bulb design (standard or quick ' response) for prompt, precise operation UPRIGHT PENDENT RECESSED (V2703 AND (V2707 AND PENDENT The die cast frame is more streamlined and attractive than traditional sand cast v2704) v2708) (V2707 AND vz7oa) frames. It is cast with a hex - shaped wrench boss to allow easy tightening from many angles, reducing assembly effort This sprinkler is available in various temperature ratings (see chart on page 2) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up to W /19mm of adjustments SPRINKLER OPERATION The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient temperature rises causing the liquid in the bulb to expand When the ambient tem- perature reaches the rated temperature of the sprinkler, the bulb shatters As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE For coverage area and sprinkler placement, refer to NFPA 13 standards. TECHNICAL SPECIFICATIONS Models /S.I.N.: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent ACCESSORIES 0 Nominal Orifice Size: 1/2713 mm Installation Wrench: • K- Factor: 5.6lmp./8 1 S.I.^ Nominal Thread Size: 1/2" NPT /15mm • Open End: V27 • Max. Working Pressure: Recessed. V27-2 175ps1/1200kPa FM Global Finishes: 250 psi /1725kPa UL • Plain brass F actory Hydrostatic Test: • • Chrome plated 100% ®500psi/3450kPa ▪ White painted ** Min. Operating Pressure: 7 psi/48 kPa • Black painted ** V U Temperature Rating: See charts on page 2 & 3. • Custom painted ** i • Proprietary nickel Teflon* coating ** OR MATERIAL SPECIFICATIONS For cabinets and other accessories refer to J X-6,4.-' Upright Deflector: Bronze per UNS C22000 separate sheet `� Pendent Deflector: Bronze per UNS C51000 NOTE: Weather resistant recessed escutcheons Bulb: Glass with glycerin solution. available upon request Bulb Nominal Diameter: IP • Standard 5.0 mm A For K- Factor when pressure is measured in • Quick Response. 3.0mm Bar, multiply S.I. units by 10 0 Load Screw: Bronze per UNS C65100 * Teflon is a registered trademark of Dupont Co. Pip Cap: Bronze per UNS C65100 * *UL Listed for corrosion resistance in all Spring: Beryllium nickel configurations. Exaggerated for clarity Seal: Teflon* tape Frame: Die cast brass 65 -30 Lodgement Spring: Stainless steel per UNS S30200 JOB /OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com jctaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY C 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED. , FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 4U ■ 1U V27 K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS /S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS /S.I.N. V2704 AND V2708 QUICK RESPONSE 'APPROVALS /LISTINGS - Model' L F , ,1,.M,: ,...- ACT 1 _ / :. -7. fir - Ei 'NO •Orifice Size (inches) 1 -, `" '•r - s - %' y" �/7" Y" Yi' %z" / Vz Orifice Size (mm) 13 13 13 13 13 13 13 Nominal K Factor Imperial 5 6 5 6 5 6 5 6 5 6 5 6 5 6 ' ' Nominal K Factor S.I.^ 8 1 81 81 81 81 81 81 Response, - Standard Standard Standard Quick Quick Quick Quick Deflector Type Recessed Recessed Recessed YP U pright Pendent Pendent Upright Pendent Pendent Pendent 1 Adjustment, - - - , up to 3/4" . .' -_.�. _._ .. . .. .. ....... �...._. - up to Y2" �-�- up to Yz" , Approved Temperature Ratings F' /C'.by Agency ` ' Model • ' ` 135 °F /57 °C 135 135 ° F /57 ° C 135 °F /57 °C ' f 155 ° F /68 ° C 155 °F /68 °C 135 ° F /57 ° C 135 ° F /57 °C ' ` 175 ° F /79 °C ; 175 °F /79 °C 155 °F /68 ° C 155 ° F /68 °C 155 °F /68 °C 155 ° F /68 ° C 155 ° F /68 °C UL 200 ° F /93 ° C 200 °F /93 °C 175 °F /79 ° C 175 ° F /79 ° C 175 °F /79 °C 175 °F /79 °C 175 °F /79 °C 286 °F /141 °C 286 °F /141 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 200 ° F /93 ° C ' 360 ° F /182 ° C ` 360 °F /182 °C 286 ° F /141 ° C 286 ° F /141 ° C 286 °F /141 °C 135 ° F /57 ° C 135 °F /57 °C 135 °F /57 °C , 135 °F /S7 °C 135 ° F /57 ° C 155 ° F /68 ° C 15S °F /68 °C 155 °F /68 °C 155 ° F /68 °C 155 °F /68 °C 135 °F757 °C 135 °F /57 °C ULC 175 ° F /79 ° C 175 °F /79 °C 175 ° F /79 ° C 175 °F /79 °C 175 °F /79 °C 155 °F /68 °C 175 °F /79 °C 200 °F /93 °C 200 °F /93 °C 175 °F /79 °C 286 °F /141 °C 286 °F /141 °C 200 °F /93 ° C ; 200 ° F /93 ° C 200 °F /93 °C 200 °F /93 "C 200 °F /93 °C p 360 ° F /182 ° C 360 °F /182 °C 286 °F /141 ° C 286 ° F /141 ° C 286 ° F /141 ° C 135 °F /57 °C 135 °F /57 °C 135 °F /57 °C 135 ° F /57 ° C 155 ° F /68 ° C 155 ° F /68 ° C 135 °F /57 °C 55 ° F /68 ° C 155 °F /68 °C 135 °F /57 °C FM # 175 175 °F /79 ° C 55 °F /68 °C 175 ° F /79 °C 175 °F /79 °C 155 °F /68 °C None 200 ° F /93 ° C 200 °F /93 °C 175 °F /79 °C 200 °F /93 °C 200 °F /93 °C 175 °F /79 °C 286 °F /141 °C 286 °F /141 °C 200 °F /93 ° C 200 ° F /93 ° C 286 ° F /141 ° C 286 ° F /141 ° C 360 ° F /182 ° C 360 ° F /182 ° C 135 ° F /57 ° C 135 ° F /57 ° C , 135 ° F /57 ° C 135 ° F /57 ° C 135 ° F /57 ° C 155 °F /68 °C 55 °F /68 °C 155 ° F /68 ° C 15S °F /68 °C 155 °F /68 °C 135 ° F /57 ° C 35 ° F /57 °C NYGMEA A 62 -99 -E 175 °F /79 °C 175 °F /79 °C 175 °F /79 ° C 175 ° F /79 ° C 175 °F /79 °C 155 °F /68 ° C 155 °F /68 °C 200 ° F /93 ° C , 200 ° F /93 ° C 175 ° F /79 ° C 175 ° F /79 °C l 286 ° F /141 ° C 286 °F /141 °C 200 °F /93 °C 200 ° F /93 ° C 200 °F /93 °C 200 °F /93 °C 200 ° F /93 ° C 360 °F /182 °C 360 °F /182 °C 286 °F /141 ° C 286 ° F /141 ° C 286 ° F /141 ° C - - 135 ° F /57 ° C 135 °F /57 °C 135 °F /57 ° C 135 ° F /57 ° C 35 ° F /57 ° C 155 °F /68 °C 155 °F /68 °C 55 ° F /68 ° C 155 °F /68 ° C 155 °F /68 °C 135 ° F /57 ° C 135 ° F /57 ° C CSFM # 7690. 0531:112 75 °F /79 °C 175 °F /79 °C 175 ° F /79 ° C 175 ° F /79 ° C 175 °F /79 °C 155 ° F /68 ° C 155 ° F /68 ° C } 200 ° F /93 ° C 20093°C 200 ° F /93 ° C , 200 ° F /93 ° C 200 °F /93 °C 175°F/79°C 175 ° F /79 °C 286 ° F /141 ° C , 286 °F /141 °C 286 °F /141 °C 286 ° F /141 ° C 286 °F /141 °C 200 ° F /93 ° C 200 ° F /93 ° C ' 360 ° F /182 ° C 360 ° F /182 ° C I 135 °F /57 °C 155 ° F /68 ° C 175 135 °F /57 °C 75 °F /79 °C 135 ° F /57 ° C 155 °F /68 °C 135 °F /57 °C LPCB 175 F /93 °C 175 ° F /79 ° C 175 °F /79 °C 175 °F /79 °C None ' None None , 286 °F /141 °C 200 ° F /93 ° C 200 °F /93 ° C 200 ° F /93 ° C 360 °F /182 °C 286 °F /141 °C i 135 °F /57 °C 135 °F /57 °C 135 /57 ° C 35 ° F /57 °C 155 °F /68 °C 155 °F /68 °C 135 °F /S7 °C 155 ° /68 " 155 °F /68 °C 135 °F /57 °C V 175 ° F /79 ° C 175 ° F /79 ° C 155 °F /68 °C 175 ° F /79 ° C 175 °F /79 °C ' 155 °F /68 °C None ' 200 ° F /93 ° C 200 ° F /93 ° C 175 °F /79 °C 200 ° F /93 ° C 200 °F /93 °C 175 °F /79 °C . 286 ° F /141 ° C 286 °F /141 °C 200 °F /93 °C 286 °F /141 °C 286 °F /141 °C ' 200 °F /93 °C ' 360 ° F /182 ° C 360 ° F /182 ° C 8 Listings and Approvals as of printing All are approved open, except for areas designated "No" ^ For K Factor when pressure is measured in Bar, multiply S I units by 10 0 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED octaullc° FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40. 10 V27, K506 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE RATINGS All glass bulbs are rated for temperatures from -67°F/-55°C to those shown in table below. Temperature - 'FM • Victaulic Sprinkler Temperature Part . Nominal Temperature Maximum Ambient • Classification Identification Rating .Temperature Allowed Glass Bulb Color 00 ; Ordinary , A 135 1 Orange 57 38 155 100 8 Ordinary Red 68 3 Intermediate , E 79 175 65 150 Yellow ' Intermediate F 200 150 Green 93 65 286 225 - High Blue 141 107 360 300 Extra High* K Purple 182 149 Open No Bulb t Standard response only. All are approved open, except for areas designated "No" 150/65 if wax coated ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model-Number - www.victaulic.com ictaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED. FIRE PROTECTION PRODUCTS - AUTOMATIC SFRI 4hLLERS 4U. J. U Standard Spray; Upright, Pendent and Recessed Pendent MODELS /S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS /S.I.N. V2704 AND V2708 QUICK RESPONSE WARNING A ,A WARNING • Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding c with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. • Installation rules, especially those governing obstruction, must be strictly followed. 0 • Painting, plating, or any re- coating of sprinklers (other than that sup- plied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and /or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association document NFPA 25 that describes care and maintenance _ of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that Ci im a ill must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044 -0031 USA, Telephone: 001 - 610 - 559 -3300. DIMENSIONS Standard Pendent — V2707, V2708 Standard Upright — V2703, V2704 373aM 3T3ign 60 mm qn/ 1 s/e'/ ' 411 Vern 41 mm �� 604317h/ 60:b65n 1.4) i 1 ,, 25mm 1 'h" Adjustment Recessed — V2707, V2708 (drawing not to scale) 255' /60 mm `— Max Hole 2'/51 mm n Min Hole } 17 mm 710/1 _ I' re Typical ,ZL/�/I. l .I riga 30 m T ical Ceiling The } i6 U r , ®.�Il } r l r I k'/ i, � / ��_�I� Finished Surface r 30 m 43 mm �./ MAXIMUM RECESS 2%7 75 mm MAXIMUM EXTENSION www.victaulic.com �IctaUllc° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED • FIRE PROTECTION PRODUCTS - AliTOMATIC SPRINKLERS 40. 10 Standard Spray; Upright, Pendent and Recessed Pendent MODELS /S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS /S.I.N. V2704 AND V2708 QUICK RESPONSE DIMENSIONS 3 /4" Adjustment Recessed — V2707, V2708 (drawing not to scale) 2%"/60 mm Max Hole 2 "/51 mm Min Hole '4s'/ � �Z�,��' 3 7 mm 24 mm 16 rnm �� of , i Typical Ceding Tile A 0 Finished Surface . 24 mm MAXIMUM RECESS 2'lds "/ /5 mm MAXIMUM EXTENSION AVAILABLE WRENCHES Sprinkler Type V27 -2 Recessed V27 Open End V2707, V2708 Pendent yes yes V2707, V2708 Recessed Pendent , yes — V2703, V2704 Upright yes yes DISTRIBUTION PATTERNS Models /S.I.N. V2707, V2708 K5.6 standard pendent and recessed pendent distribution patterns — trajectory 10' i 3.0m •...o. •r .... i I tt • 8' 1 i _ _ 24m I i 1 i 1 ♦:♦ i i' t i ` ' • ♦ i • ■ l i t ___ .` :._.__.. ♦ I I 1 4. i t B 3 N. I ♦ ' • F� 3 I 4' { x j • z ♦ € I \ ', •( 2' + I IN � ' - - 06m 1 I ' • 1 • I ♦ . g • 2 4' 6 8 1�0 12' 14' 0.6m 1 2m 18m 2 4m 3 Om 3 7m 4 3m 7 psi 15 psi 30 psi 48 kPa 103 kPa 207 kPa See notes on next page. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED jctaulid FIRE PROTECTION PRODUCTS -- AUTOMATIC SPRINKLERS 4U. .I. U , Standard Spray; Upright, Pendent and Recessed Pendent MODELS /S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS /S.I.N. V2704 AND V2708 QUICK RESPONSE DISTRIBUTION PATTERNS Models /S.I.N. V2703, V2704 K5.6 standard upright distribution patterns — trajectory 10' i •■ •�• I i i 3 2 • I P 9 • •• i i i = 1W • 11 tt i t r 1 ; `•• F •••; 7 � . F 8. t • ' $ S 24m 1 7 • E � • � ! < 9 _.._ I ._. ,_.. ,_�•. — _._ — i__ _.. _4. .., S E • I i •' •� ' j{ 6' S � • 1 • • - i I S • I. •• 4' 1 261 r - -1- — - ---1 t--1- --1-141-1— -',11-1.- I • - L 4 1 • c i 2 , , I ? ! _ -- i " i _.__.. ._ t . • _ . • E • 0 6m 2' 4' 6' 8' 10' 12' 14' 16' 0 6m 1 2m 1 8m 2.4m 3 Om 3 7m 4 3m 4 9m 7psi ■••■••• 15 psi 30 psi 48 kPa 103 kPa 207 kPa NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, floor - wetting, and wall - wetting patterns for these specific Victaulic FireLock automatic sprinklers They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED jctaulic° • ��K0 �nEP��C�QNPnOm�7 -�T��C SPRINKLERS ,~~"10U &���� � �� �m��� �� ��"�� Standard Spray; Uphgh\, Pendent and Recessed Pendent MODELS/S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N. V2704 AND V2708 QUICK RESPONSE WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details ___ _ . NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. • www.victaulic.com jctaulie VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY C 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED p l1171_ rirr7,17T._ lgrrMMrgrTrMr7rrn71MMMIIIIIIMMIMMNIIIIMIII711M ; • ;. • Lummullimm i Standard Spray; Upright, Pendent and Recessed Pendent MODELS /S.I.N. V2703 AND V2707 STANDARD RESPONSE MODELS /S.I.N. V2704 AND V2708 QUICK RESPONSE III II III III 1111111111111111111111111111111 WCAS- 6AYRHZ For complete contact information, visit www.victaulic.com 40.10 2544 REV F UPDATED 1/2008 V,ctaaul C VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED MP. -� LPCB I 11 / ';( ' �\n ','" VNIIPO SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS /S.I.N. V2709 AND V2710 These Model V27, standard spray horizontal sidewall sprinklers are designed for up to ordinary } ? � `_ " * v Hazard per NFPA 13, and can be used for standard or recessed installations The design provides __ , , , ___ - ' \ ° a crescent - shaped water discharge pattern for installation along a wall or under a beam or ceiling. � The design incorporates state -of- the -art, heat responsive, frangible glass bulb design (standard or STANDARD HORIZONTAL SIDEWALL quick response) for prompt, precise operation. (v2709, v2710) The die cast frame is more streamlined and attractive than traditional sand cast frames It is cast with M. a hex - shaped wrench boss to allow easy tightening from many angles, reducing assembly effort This sprinkler is available in various temperature ratings (see chart on page 2) and finishes to meet ( many design requirements ' Ile 1 v The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up I to 3 /4"/19 mm of adjustments. I , • ., i RECESSED HORIZONTAL SIDEWALL (V2709, V2710) SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient temperature rises causing the liquid in the bulb to expand When the ambient temperature reaches the rated temperature of the sprinkler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE: For coverage area and sprinkler placement, refer to NFPA 13 standards JOB /OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com jctaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED FIRE PROTECTION PRODUCTS - - AUTOMATIC SPRINKLERS 4U • 1 1 V27, K5 Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS.V2709 AND V2710 TECHNICAL SPECIFICATIONS: Models /S.I.N.: V2709, V2710 ACCESSORIES Style: Horizontal Sidewall or Recessed Installation Wrench: / I /z Horizontal 'Sidewall • Open End V27 Nominal Orifice Size: 1/2713 mm • Recessed V27 -2 K- Factor: 5 6 Imp /8.1 S.I.^ Sprinkler Finishes: J Nominal Thread Size: 1/2"/15 mm • Plain brass Max. Working Pressure: • Chrome plated 175 psi /1200kPa FM Global • White painted ** 0 250 psi/1725 kPa UL black painted ** Factory Hydrostatic Test: 100% ®500 psi! • Custom painted ** • 3450kPa • Proprietary Nickel /Teflon* Coating** Min. Operating Pressure: 7psi /48kPa Temperature Rating: See chart on page 2. 011‘ For cabinets and other accessories refer to i MATERIAL SPECIFICATIONS separate sheet LAI � Horizontal Deflector: Commercial bronze per NOTE Weather resistant recessed escutcheon . s ,� 1 1 UNS C22000 available upon request Bulb: Glass with glycerin solution A For K- Factor when pressure is measured in N �� i� Bulb Nominal Diameter: Bar, multiply S.I. units by 10.0. I • Standard• 5.0 mm * Teflon is a registered trademark of Dupont Co • Quick Response. 3.0mm * *Also, UL Listed for corrosion resistance in all L Screw: Low Silicon bronze per configurations UNS C65100 Exaggerated for clarity Pip Cap: Low Silicon bronze per UNS C65100 Seal: Teflon* tape Spring: Beryllium nickel Frame: Die cast brass 65 -30 Lodgement Spring: Stainless steel per UNS S30200 • jc VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40. 1 1 .; Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 APPROVALS /LISTINGS Model Orifice Size (inches) V," V2 i / - _ W - _- _ _ / , Orifice Size (mm) - 13 13 13 13 i 13 Nominal K Factor Imperial 5.6 5 6 5 6 5 6 5 6 Nominal K _ Factor S. I. ^ 81 8 1 81 8 1 8.1 Response Standard Standard Standard Quick , Quick Recessed Recessed Recessed Horizontal Honzonrai Horizontal Horizontal Horizontal Deflector Type Sidewall '• S dewaII* i Sidewall Sidewall (up to r1" Sidewall (up to 3 /4' adjustment) adjustment) Approved Temperature Ratings PC' by Agencyt • Model 135 °F /57 °C 135 °F /57 °C ' 155 °F /68 °C 135 °F /57 °C 135 °F /57 °C 135 °F /57 °C 175 155 °F /68 °C 155 °F /68 °C 155 155 °F /68 °C UL 200 °F /93 °C 1750F/79°C 175 °F /79 °C 175 °F /79 °C 175 286 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C i 200 °F /93 °C 360 °F /182 °C 286 °F /141 °C 1350F/57°C 135 °F /57 °C 155 °F /68 °C 135 °F /57 °C ' 135 135 °F /57 °C 175 °F /79 °C 155 °F /68 °C 155 °F /68 °C 155 °F /68 °C 155 °F /68 °C ULC 200 °F /93 °C 175 °F /79 °C 175 °F /79 °C 175 °F /79 °C 175 °F /79 °C 200°F/93°C 286 200 °F /93 °C 286 °F /141 °C 200 °F /93 °C 200 °F /93 °C 360 °F /182 °C j 135 °F /57 °C 155 °F /68 °C 135 °F /57 °C 135 °F /57 °C 135 °F /57 °C 175 155 °F /68 °C 155 °F /68 °C 155 °F /68 °C FM 200 °F /93 °C 175 °F /79 °C 175 °F /79 °C 175 °F /79 °C None 286 200 °F /93 °C 200 °F /93 °C 200 °F /93 °C 360 0F /182 0C 286 °F /141 °C _ _ _ 135 °F /57 °C 135 °F /57 °C ___ - 155 °F /68 °C 135 °F /57 °C + ° 135 °F /57 °C 135 °F /57 °C NYC/MEA # 62-99-E 175 °F /79 °C 155 °F /68 °C 175 °F /79 °C 155 °F /68 °C 155 °F /68 °C 200 °F /93 °C 1750F/79°C 200 °F /93 °C 175 175 °F /79 °C 286 j 200 °F /93 0C i 286 °F /141 °C 200 °F /93 °C 200 °F /93 °C 360 °F /182 °C 135 °F /57 °C 155 °F /68 °C ! 135 °F /57 °C 135 0F /57 0C 135 °F /57 °C 135 °F /57 °C 175°F/79°C 155 °F /68 °C 1550F/68°C 155°F /68°C 155 °F /68 °C CSFM # 7690. 0531:112 200 °F /93 °C 1750F/79°C 175°F /79 °C 175 °F /79 °C 175 °F /79 °C 286 °F /141 °C 200 °F /93 °C 200 °F /93 °C 200 200.F/93°C 360 °F /182 °C 266 °F /141 °C 135°F/57°C _ 135 °F /57 °C 155 °F /68 °C j 155 °F /68 °C LPCB # 104b/01 175 °F /79 °C None I 175 °F /79 °C None None # 104b/02 200°F/93°C 200 °F /93 °C 2860F/141°C j 286 °F /141 °C 360 °F /182 °C 135 °F /57 °C 135 °F /57 °C : 155 °F /68 °C 1350F/57°C S5 °F /68 °C 135 °F /57 °C VNIIPO 75 0 F /79 0 C 1 155°F/68°C 175 °F /79 °C 155 °F /68 °C None 200 °F /93 °C 175 °F /79 °C 200 °F /93 °C 175 °F /79 °C 286 I 200 °F /93 °C 286 °F /141 °C 200 °F /93 °C ' 360 °F /182 °C I 1 $ Listings and Approvals as of printing All standard responses are approved open ^ For K Factor when pressure is measured in Bar, multiply S I units by 10 0 # Light Hazard ONLY www.victaulic.com . ictalulllc` VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 4U. J. 1 1127, K5.6 Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response Models V2709 and V2710 RATINGS All 'glass bulbs are rated for temperatures from —67°F/-55°C to those shown in table below , Victaulic. • Sprinkler Temperature 'Part Nominal Temperature Maximum Ambient ''• . • ' Classification , • Identification' ' Rating. Temperature Allowed • • Glass Bulb Color- 135 Ordinary ' A 100 Orange 57 38 155 100 Ordinary C Red 68 38 Intermediate E 175 150 Yellow 79 65 150 intermediate, 200 Green :High J ' 93 65 286 225 Blue 141 107 Extra I-110 K Purple 182 149 1 — Open No Bulb Standard response only All standard responses are approved open. ORDERING INFORMATION Please specify the following when ordering Sprinkler Model Number ' Style • temperature Rating K-Factor „ Thread Size '-Quaritlry , Sprinkler Finish Escutchebn Finish -,yVrench'Model Number jctaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.1 J. Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 WARNING A WARNING • Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. • Installation rules, especially those governing obstruction, must be strictly followed. • Painting, plating, or any re- coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler _ systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044 -0031 USA, Telephone: 001- 610 - 559 -3300. www.victaulic.com jctaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 4Uo 11 V27 K5.6 Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 DIMENSIONS Standard HSW - V2709, V2710 3789 mm 2'/ "/57 mm II � she ^ / 7A6"/ /a / II� — % I__ 11 mm 32 mm .i M� 8 mm -r -- 11� �� I i 1 I 'h" Adjustment Recessed - V2709, V2710 (drawing not to scale) 1 316% 17 mm 24167 1'3e/ 11‘7 � /yp X 43 mm 3 / , y eite freff rte/ Ii(SQ/ONir 1 Fnshed Ceiling 4- 12'/102 - 305mm , Fi nished Ceding 4- 12'/102 -305mm Per NFPA I Per NFPA l t ! /51mm 2%'/60 mm / 2 '/60 mm 2Ns "/ IC 'a'I Min Hole Max Hole 75 mm � Min Hole Ma Hole IN i le Finished Surface I II Finished Surface I II _..i I.-- Typical Wall -4 I — Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS 3 /4" Adjustment Recessed - V2709, V2710 (drawing not to scale) 'Xi 24 mrn F 2W/ �s %18 mill 1'4167 15A57 ��y/ mm � dj �// . � j �� Q p Jj/ 377 mm X 377 mm �rJ�jy/,y 1 21 I Finished Ceiling Finished Ceiling 4- 12'/102 -305 mm 4- 12'/102 -305 mm YYY Per NFPA IA Per NFPA _ � �� 2751 o 2 W /60 inns ' `� �I ,, Max _ „„', 2751 m 2 44/60 mm !. Mm Hole � Hole 75 mm ll..L 1 m Min Hole Max 1 Hole Ill' 1 Ill' Finished Surface I I Finished Surface -+1 1_ Typical Wall +I I.— Typical Well MAXIMUM EXTENSION MAXIMUM RECESS VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED � C$aul l d • FIRE PROTECTION PRODUCTS -- AUTOMATIC SPRINKLERS 40. 1 1 p, g 7 ,, 1 , 1 r . Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 AVAILABLE WRENCHES V27 -2 V27 Sprinkler Type Recessed Open End No escutcheon yes yes i With escutcheon yes — DISTRIBUTION PATTERNS Models V2709, V2710 K5.6 Standard Horizontal Sidewall and Recessed Horizontal Sidewall Distribution Patterns — Trajectory 30m •• I • . 24m [ Q % i • 1.8 m i \ ! a •• 12m - S ' 1 • 1 , • , , 0,6m i t I 3i 4 • 0 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 0,6m 1,2m 1,8m 2.4m 30m 37m 43m 49m 55m 6.1m 67m 73m 79m 7psl ...•• ■•• 1Spsl 30 psl , 48 kPa 103 kPa 207 kPa Models V2709, V2710 K5.6 Standard and Recessed Horizontal Sidewall Distribution Patterns — Plan View 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 06m 12m 18m 2.4m 30m 3.7m 43m 49m 55m 61m 67m 73m 7.9m 85m • • • 06m • q ' > • 12m 6 • • • 6' • 1.8 m • ' • ■ 24m ,•� • 10' 30m 37m 14' �.• 43m ... 16' 49m 7psl ■••■•s 15 psi 30 psi , 48 kPa 103 kPa 207 kPa www.victaulic.com /Ctalullc VICTAULIC I5 A REGISTERED TRADEMARK OF VICTAULIC COMPANY C 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED _ Standard Spray Horizontal Sidewall and Recessed Horizontal Sidewall Standard and Quick Response MODELS V2709 AND V2710 WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE 1 Data shown is approximate and can vary due to differences in installation. 2. These graphs illustrate approximate trajectories, floor - wetting, and wall - wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties 111111111 111111 11111 1 11 11111111111111 I I I WCAS 7PQP9R For complete contact information, visit www victaulic.com 40.11 2545 REV F UPDATED 1/2008 1ctaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2008 VICTAULIC COMPANY ALL RIGHTS RESERVED ..� A PAP[Z _SIR LISTED Dry Type Standard Spray, Light Hazard - Horizontal Sidewall and Recessed Horizontal Sidewall / 1. , I fir; :4 Y., f ; , ._ V3609 STANDARD RESPONSE " " ° ., 1, „ -1k V3610 QUICK RESPONSE 1 / , FLUSH DRY RECESSED DRY SLEEVE & SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL N EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL The V36 dry Sprinkler is used in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples The Model V36 Dry Type Horizontal Sidewall Sprinkler utilizes a frangible glass bulb At the bulb's rated temperature, the sprinkler opens releasing the bulb seat assembly, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube At this time, water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern. The heart of the Model V36 sprinkler's proven actuating assembly is a hermetically sealed frangible glass bulb that contains a precisely measured amount of fluid When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the bulb exceeds the strength of the glass causing the glass to shatter This results in water discharge which is distributed in an approved pattern COVERAGE: For coverage area and sprinkler placement, refer to NFPA 13 standards. NOTE: These sprinklers meet the new test requirements in UL 199, effective March 26, 2004. JOB OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com •CtolUI1C' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA- FIRE PROTECTION PRODUCTS - AUTOM/ TIC SPRINKLERS 40.64 F USTED Dry Type Standard Spray, Light Hazard �� Horizontal Sidewall and Recessed Horizontal Sidewall ;,R;s' ,, A,, ,; i r 4 , 0 , z — ' � -= _ s - - - -" V3609 STANDARD RESPONSE - - -, V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE & SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL 4 1 till EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL TECHNICAL SPECIFICATIONS: I I :IVArifeYiJWA/ArAfAr rAvArrA . 111 A ,chi H:N1_ i di A Ait w a o r myi/s�isrsvisrs4s 5 srivsrsv I III Mi I Exaggerated for clarity Models: V3610 and V3609 ACCESSORIES Style: Horizontal Sidewall and Recessed Installation Wrench: Model V36 Open End and Horizontal Sidewall Recessed Wrenches fit all V36 Series frames. Nominal Orifice Size: / /13mm Finishes: Orifice Insert: Stainless steel per UNS S30300 • Plain brass K- Factor: 5.6 Imp. /8,1 S.l.^ • Chrome plated ° Nominal Thread Size: 1" NPT /33 7mm • White Painted ° Max. Working Pressure: 175 psi /1200kPa • Flat black painted ° Factory Hydrostatic Test: 100% @ 500 psi/ • Custom painted ° 3450kPa • Wax Min. Operating Pressure: 7psi /48kPa • Proprietary Nickel Teflon* Coated ° Temperature Rating: See chart on page 3. For cabinets and other accessories refer to separate sheet. MATERIAL SPECIFICATIONS A For K- Factor when pressure is measured in Deflector: Brass per UNS C22000 or Stainless Bar, multiply S I units by 10.0. Steel per UNS S30400 * Teflon is a registered trademark of Dupont Co. Bulb: Glass with glycerin solution ° UL Listed for corrosion resistance in all con- • Standard: 5.0 mm figurations. • Quick Response: 3 0mm NOTES - Split Spacer: Stainless steel per UNS S30300 1. Weather resistant escutcheon available upon Load Screw: Brass per UNS C36000 request. Pip Cap: Stainless steel per UNS S30300 2. Only the Plain Brass and Nickel Teflon Spring Seal Assembly: Teflon* coated Beryllium finishes are FM approved. nickel alloy and Stainless steel per UNS S30300 Frame: Die cast brass Outer Tube: Galvanized steel pipe Inner Tube: Stainless steel per UNS S30400 Escutcheon: 1010 - 1018 mild steel and Stainless Steel Torsion Spring: Stainless Steel Wire www.victaulic.com EL'ta'111I1L° Vic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA ---1 • FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40. 64 .... ‘..• LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall { Ial - ' tli ' ( - Ifj - ---1 .'' ' fr - rgir , ' ' t' :77. , ' - .0 , .0 .-ii ', " '‘. VI ',b•--",- V3609 STANDARD RESPONSE 6, .. V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE & SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL r 1 -. ;•[ ...P ' - k s.,r -1 --- v - '-- EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL APPROVALS/LISTINGS Orifice Nominal Approved Temperature Ratings Model Size K-Factor Response Deflector Type i ,-, 'i.•, ,,,°)., ,L - , 11 6.$ ": , :' : O 7 i M. 1 - ClibiA s 2 ;":;::.2:-V; 7. I r , ii.ist - ' : '/- ' 5 6 135, 155, 200, 286 135, 155, 200, 286 : 135, 155, 200, 286 V3610 ' ; Quick ; Horizontal Sidewall 13 1 8 ' 57, 68, 93, 141 57, 68, 93, 14' ■ 57,68, 93, 141 1/2 ' 56 , Recessed Hor zonal 135, 155, 200, 286 i 135, 155, 200, 286 ; 135, 155, 200 V3610 13 8 1 Quick . Sidewall 57, 68, 93, 141 i 57, 68, 93, 141 57, 6 8, 93 1/2 ' 56 135 155, 200, 286: 135 155 200, 286 , 135, 155, 200, 286 V3609 Standard ' Horizontal S.dewall - ' " ' 13 8 1 57, 68, 93, 141 57, 68, 93, 141 57, 68, 93, 141 - , - 1 6 , 56 Recessed Hor.zonzal 135, 155, 200, 286 135, 155, 200, 286 135, 155, 200 Standard V3609 13 8 Sidewall 57, 68, 93, 141 , 57, 68, 93, 141 ' 57, 68, 93 t Listings and approval as of printing. A For K-Factor when pressure is measured in Bar, multiply S I units by 10 *Light Hazard Only - Listed for light hazard only with deflector from 4" - 12" below the ceiling CO Approved for V3609 and V3610 up to 48" length RATINGS All glass bulbs are rated for temperatures from -67°F/-55°C to those shown in table below. Temperature - 'FPC Sprinkler Temperature Nominal Temperature Maximum Ambient Classification Rating Temperature Allowed Glass Bulb Color 135/155 100 Ordinary 135/155 57/68 38 200 , 150 .---..-- ........_ . „ ....---- Intermediate ' Green 93 65 . ° 286 225 High . Blue 141 107 www.victaulic.com ictaulic° vicrAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ID 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA FIRE PROTECTI mm ���� ompnogucT� AUTOMATIC -���"���w-� �� ����� ���� ��^��:�� �~��� ��~�'�� �~ ~ ~~ LISTED Dry Type Standard Spray, Light Hazard ' --' -- --` Horizontal Sidewall and Recessed Honzonta|Sidewa|| V3609 RESPONSE *15,74 L � V3610 QUICK RESPONSE \/ ' FLUSH DRY RECESSED DRY SLEEVE & SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL ORDERING INFORMATION Please specify the following when ordering: Spr,nkler „. Sty ' . . . . �� m*nr �~~:~ K-Factor Quantity . i Sperkler`mo _ Escutcheon . face of fitting to the finished ceiling line regardess of ,scutcxeorused -- ----- -`------ ---- ------ --'`-- --- AVAILABLE WRENCHES Model V36 Open End and Recessed Wrenches fit all V36 Series frames. • wwmvictavxczvm VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY mz00owcTAoucCOMPANY ALL RIGHTS RESERVED PRINTED IN THE LISA FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40.64 ., , ,; ; ,_, i ,, , ! I LISTED ________ Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall i . ' , , § 2, , ;l tvi _ —_,,,, — , , _ t ,r. { ,yak, b r= X V3609 STAND RESPONSE � � ,i p ' = =` • __ fl-=/' � V3610 QUICK RESPONSE 1, FLUSH DRY RECESSED DRY SLEEVE & SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL f , Cr te EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL WARNING A A WARNING • Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding 0 , C with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. • Installation rules, especially those governing obstruction, must be strictly followed. • Painting, plating, or any re- coating of sprinklers (other than that sup- 0 plied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and /or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler _ systems. In addition, the authority having jurisdiction may have addi- tional maintenance, testing, and inspection requirements that must be followed. milir If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044 -0031 USA, Telephone: 001 - 610 - 559 -3300. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA jctaulid FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40.64 "Jrc i -o r, j ® FM C® • LISTED Dry Type Standard Spray, Light Hazar Horizontal Sidewall and Recessed Horizontal Sidewall n ' ' �' ,y: i; . - 3'r= -- V3609 STANDARD RESPONSE ,4 I-M. `'' ' ` V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE & SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL A lite l EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL DIMENSIONS NOTE: The "A" dimension of a dry sprinkler which extends into freezers from wet pipe systems should be sized to provide at least 14° between the freezer's outside wall or ceiling and the wet pipe. I�Mi In') ,. M•,w, / l) l' NM ��� /I �CSWUCnea _I h Tee with rarnt 01.1 it sa H Ph' Sfin Da ole es Wall 3' Da - f toe . I I- tee w lh vne oN e. sae s spr pkler tnacid size as car osier :tredd sue 5, pale 4. No .2 i/ 2A' — .— x- xge 4♦o2 /� 4 1, .n / da c Flush ' Sleeve & Skirt 1 (Min, I NPT ipl IN— e with same outlet slie 2sn. 3s sprinkler [bond sixe See pace 4, No 2 Plain Barrel 1 i ;Min I Hole In all Udall Cop H ole In UJall c - - __ I L _ ;� 1 Crillal _ f — 1'TIPI - �. i,l 1,_..77 31 II ;Ili r, T + j_ Da Tee mrllcone owl[ +r _ L-- —_ - '1 j x � 11 I as °prnnlCr [mead cm N w.l'Iese Min Da 5[e Page 4,No1 ;\ _sr.'cheon Tee v.ith saic :outlet site ■k _in\h8 sprinkler lh•ead •u iv M � I See page 4. fin' \ ) ♦ « l ' h1ar m � (Mr .1. iV. t ae ' Extended Recessed DEFLECTOR TO CEILING DISTANCE 4 - 127102 - 305MM FOR ALL CONFIGURATIONS SHOWN ABOVE. • www.victaulic.com ictaUlIC' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA • FIRE PROTECTION PRODUCTS -• AUTOMATIC SPRINKLERS 40. 64 :1 c �i - 1 LISTED ® I Dry Type Standard Spray, Light Hazard Horizontal Sidewall and ` , : Recessed Horizontal Sidewall . V3609 STANDARD RESPONSE ' ° - ' x'' , t / r V3610 QUICK RESPONSE 1, FLUSH DRY RECESSED DRY SLEEVE & SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL * e. .;;;, EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS MODELS V3610, V3609 HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS - TRAJECTORY f y • 3.0m , •• I . � i �4._. ; 6' i 1 •, I *•, ; , 1.8m f ' 1 _•• !. _ 1 1 \ 1 ••, 4' s 1 •• • 1 • 2 ' 1 ' 1 \ 1 •� 0.6 m ' 1 ; • I , • • ' 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 0.6 m 1.2 m 1.8 m 2.4 m 3.0 m 3.7 m 4.3 m 4.9 m 5.5 m 6.1 m 6.7 m 7.3 m 7.9 m 7psi -■• -•• 15 psi 30 psi 48 kPa 103 kPa 207 kPa MODELS V3610, V3609 HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS - PLAN VIEW 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0.6 m 1.2 m 1.8 m 2.4 m 3.0 m 3.7 m 4.3 m 4.9 m 5.5 m 6.1 m 6.7 m 7.3 m 7.9 m 8.5 m 2' ' . i , • • D.6m j • , 4' i 1 • , • •i • 1.2m I / - 4 • • 1.8 m j : : • 8' .•� • 24m . ••� 1 • 1 30m . �.��• --- "; _ .___ - --- •• 12' e• ■ I • _ ; 1 . „. 37m • • 14' j I j �� _ , , _ 4.3m 16' • 1 4.9 m • 7psi -•• -•• 15 psi 30 psi 48 kPa 103 kPa 207 kPa See notes on last page. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA jctauli -- --- C' ( h �c .. .. LISTED Dry Type Standard Spray, Light Hazard '� ` Horizontal Sidewall and Recessed Horizontal Sidewall ',Vg fr _ J. �,,' - �'� ,;; „, _ : V3609 STANDARD RESPONSE .k - t "' V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE & SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL NOTES 1 Data shown is approximate and can vary due to differences in Installation. 2 These graphs illustrate approximate trajectories, floor - wetting, and wall - wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprin- kler spacing rules for installation. Refer to the appropriate NFPA National Fire Code and the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties 3 All patterns are symmetrical to the centerline of the waterway IMPORTANT INSTALLATION INFORMATION For detailed installation instructions, see publication 1 -40. No. 1 Victaulic Model V36 Series Dry sprinklers should be installed in accordance with NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler wrench may be used with extreme care for lengths up to approximately 18 ". Excessive force may distort the frame thus destroying the unit No. 2 Dry sprinklers MUST be installed only into the outlet of a cast or malleable iron tee No. 3 DO NOT install dry sprinklers into any couplings or threaded elbows. In addition, DO NO i install dry sprinklers into any fitting that interferes with thread penetration NOTE: The end seal of the dry sprinkler MUST NOT bottom out in the fitting. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details NOTE This product shall be manufactured by Victaulic or to Victaulic specifications All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations US 14 WORLD HEADQUARTERS CANADA CENTRAL AND SOUTH AMERICA P.O. Box 31 905- 884 -7444 1- 610 - 559 -3300 Easton, PA 18044 -0031 USA 905 -884 -9774 (fax) 1- 610 - 559 -3608 (fax) 4901 Kesslersville Road viccanada @victaulic.com vical @victaulic.com Easton, PA 18040 USA EUROPE ASIA PACIFIC 1- 800 - PICK -VIC (1- 800 - 742 -5842) 32- 9- 381 -15 -00 86 -21- 54253300 1-610-559-3300 32 -9- 380 -44 -38 (fax) 86 -21- 54253671 (fax) 1- 610- 250 -8817 (fax) viceuro @victaulic.be vicap @victaulic.com pickvic@victaulic.com UNITED KINGDOM MIDDLE EAST www.victaulic.com 44 (0) 1438741100 971 -4- 883 -88 -70 III II 1111111111IIIIIII II II IIIIIIIIIIIIIII 44 (0) 1438313883 (fax) 971 -4- 883 -88 -60 (fax) WCAS- 6AGRC7 viceuro @victaulic.be UPDATED 7/2006 40.64 3127 REV H jctaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA y • Ilk 'tag ill:. •: ►. _ i - Li JRwAnui il yt �; ,n ��.� �J � FM Dry Type Standard Spray Upright V3601 STANDARD RESPONSE V3602 QUICK RESPONSE • DRY UPRIGHT The Model V36 Series Dry Type Upright Sprinkler has been redesigned utilizing stainless steel internal components. The V36 Dry Sprinkler is used in special applications such as freezing environ- ments. As an example, they may be efficiently used when connected to a wet type sprinkler system and extended into an unheated attic space The Model V36 Dry Type Upright Sprinkler utilizes a frangible glass bulb. At the bulb's rated tem- perature, the sprinkler opens releasing the bulb seat assembly, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector, in the approved discharge pattern. The heart of the Model V36 sprinkler's proven actuating assembly is a hermetically sealed frangible glass bulb that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the bulb exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. • COVERAGE: For coverage area and sprinkler placement, refer to NFPA 13 standards. NOTE: These sprinklers meet the new test requirements in UL 199, effective March 26, 2004 JOB OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com j ctaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA � —_ -- -_ FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40.62 1/36 K5 s U FM Dry Type Standard Spray _ _ Upright s° V3601 STANDARD RESPONSE , V3602 QUICK RESPONSE 6 f Po DRY UPRIGHT TECHNICAL SPECIFICATIONS: Models: V3602 and V3601 ACCESSORIES _ :14— _ Style: Upright Installation Wrench: ModelV36 Open End and " 17 1 o r Nominal Orifice Size: 1/2" /13mm Recessed Wrenches fit all V36 Series frames. Orifice Insert: UNS S30300 Finishes: ` I K- Factor: 5 6 Imp /8 1 S.I.^ Plain brass Nominal Thread Size: 1" NPT /33.7mm • Chrome plated `� Max. Working Pressure: 175 psi /1200kPa • White Painted ° . � �����4� Factory Hydrostatic Test: 100% @ 500 psi/ • Flat black painted a ;� � � �' 3450kPa • Custom painted a jt Min. Operating Pressure: 12 psi /83kPa • Wax ° 1 0 1 Temperature Rating: See chart on page 3 • Lead ° 1 , Wax /Lead MATERIAL SPECIFICATIONS • • Proprietary ° Nickel Teflon* Coated ° 1 1 Deflector: Brass per UNS C22000 or Stainless For cabinets and other accessories refer to Steel per UNS S30400 separate sheet ■1 1 Glass with glycerin solution B Glth glilution For K- Factor when pressure is measured In • Standard- 5.0 mm 1 k • Quick Response- 3.0mm ` Teflon Is a registered trademark of Dupont Co. Split Spacer: Stainless Steel per UNS S30300 ° UL Listed for corrosion resistance in all con Load Screw: Brass per UNS C36000 Escutcheon ). �s figurations Optional ;l Pip Cap: Stainless Steel per UNS S30300 �;/ Spring Seal Assembly: Teflon* coated Beryllium nickel alloy and Stainless Steel per UNS S30300 Exaggerated for Clarity Frame: Die cast brass Outer Tube: Galvanized steel pipe Inner Tube: Stainless Steel per UNS S30400 Torsion Spring: SST Wire www.victaulic.com ®L'$.20L1IB[. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED. PRINTED IN THE USA • FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40. 62 Dry Type Standard Spray -_.�. Upright IT 4 V3601 STANDARD RESPONSE ( d V3602 QUICK RESPONSE 4r' .,=. R i DRY UPRIGHT APPROVALS /LISTINGS Orifice Nominal Approved Temperature Ratings Model Size K- Factor Response Deflector Type *WC k * t i ' r: rIrn t C? TXR :Y . (r., + V.C; 1/2 5 6 135, 155, 200, 2861135, ' 155, 200, 286 ` 135, 155, 200, 286 V3602 13 8 1 Quick Uongiit 57, 68, 93, 141 57, 68, 93, 141 ' 57, 68, 93, 141 I; „ 5 6 _ _ � 135, 155, 200, 286. 135, 155, 200, 2861 135, 155, 200, 286 V3601 13 8 1 Standard . Upright 57, 68, 93, 141 , 57, 68, 93, C4' 57, 68, 93, 141 t Listings and approval as of printing. A For K- Factor when pressure is measured in Bar, multiply 5.1 units by 10 *Listed for all hazards t Approved for V3601 and V3602 dry sprinklers up to 48" length RATINGS All glass bulbs are rated for temperatures from - 67 °F / -55 °C to those shown in table below. Temperature - °F / °C Sprinkler Temperature Nominal Temperature Maximum Ambient Classification Rating Temperature Allowed Glass Bulb Color Ordinary 57/685 380 > Orange /Red Intermediate l 200 1fi0 Green High 181 227 Blue www.victaulic.com jCtaUlie VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40.62 V36 J(56 CD <> - :— Dry Type Standard Spray Upright V3601 STANDARD RESPONSE V3602 QUICK RESPONSE 4 DRY UPRIGHT ORDERING INFORMATION Please specify the following when ordering: Sprtnkler Niodel'NumiDer Tempefature Rahng K-Kfctor Cfuairilry ' Sprinkler Fink'h "A" Dimension - DiMension from ' face of fithng to the top of the deflector, AVAILABLE WRENCHES Model V36 Open End and Recessed Wrenches fit all V36 Series frames www.victaulic.com jctaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY C 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA • FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.62 0 FM Dry Type Standard Spray Upright 4 V3601 STANDARD RESPONSE V3602 QUICK RESPONSE � f DRY UPRIGHT WARNING A WARNING • Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. - V • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. • Installation rules, especially those governing obstruction, must be strictly followed. • Painting, plating, or any re- coating of sprinklers (other than that sup- plied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and /or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have addi- _ tional maintenance, testing, and inspection requirements that must be CP IiihY followed. Mir If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044 -0031 USA, Telephone: 001 - 610 - 559 -3300. • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA jctaullic° FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS 40.62 V36 K'''36 a FM Dry Type Standard Spray Upright V3601 STANDARD RESPONSE QUICK RESPONSE DRY UPRIGHT DIMENSIONS NOTE: The "A" dimension of a dry sprinkler which extends into freezers from wet pipe systems should be sized to provide at least 14° between the freezer's outside wall or ceiling and the wet pipe. 11/4" dal 1 — I__1I — Ph" Min Did Hole n Ceiling Ir (Min 3i °) \` Escutcheon (Sold Separately) ?fi "x3" Dia I`NPT Tee with same outlet size I I I I as sprinkler thread size See page 4, No 2 www.victaulic.com V VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA BQ.'$2111lId 1 FIRE PROTECTION OM PRODUCTS - AUTOMATIC SPRINKLERS 40.62 C A 1136, K5.6 UL FM __- Dry Type Standard Spray � __ _, _ Upright l =s. - V3601 STANDARD RESPONSE V3602 QUICK RESPONSE DRY UPRIGHT DISTRIBUTION PATTERNS MODELS V3602, V3601 UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY 2.4 (�oE ® ■■ ��� I I t 1. t L I 4' —. _� _ ® a . _ ew..., . ,, __ 1.2 m • a • • T m I i 2' 4' 6' 8' 10' 12' 14' 0.6 m 1.2 m 1.8 m 2.4 m 3.0 m 3.7 m 4 3 m 7 psi man ■■mom 15 psi 30 psi 48 kPa 103 kPa 207 kPa NOTES: 1 Data shown is approximate and can vary due to differences in installation 2 These graphs illustrate approximate trajectories, floor - wetting, and wall- wetting patterns for these specific Victaulic FireLock automatic sprinklers They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprin- kler spacing rules for installation. Refer to the appropriate NFPA National Fire Code and the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties 3 All patterns are symmetrical to the centerline of the waterway. www.victaulic.com -C$sAUlfiIC' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA gI:Z9�:l:i71II��I�i��:�: � � i��it� � u : i[��: ► . �:� �,���.�� FM Dry Type Standard Spray -- �_ — Upright V3601 STANDARD RESPONSE V3602 QUICK RESPONSE DRY UPRIGHT IMPORTANT INSTALLATION INFORMATION For detailed installation instructions, see publication 1 -40. No. 1 Victaulic Model V36 Series Dry sprinklers should be installed in accordance with NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler wrench may be used with extreme care for lengths up to approximately 18" Excessive force may distort the frame thus destroying the unit No. 2 Dry sprinklers MUST be installed only into the outlet of a cast or malleable iron tee No. 3 DO NOT install dry sprinklers into any couplings or threaded elbows. In addition, DO NOT install dry sprinklers into any fitting that interferes with thread penetration. NOTE: The end seal of the dry sprinkler MUST NOT bottom out in the fitting. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details NOTE This product shall be manufactured by Victaulic or to Victaulic specifications All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. us t4 WORLD HEADQUARTERS CANADA CENTRAL AND SOUTH AMERICA P.O. Box 31 905- 884 -7444 1- 610 -559 -3300 Easton, PA 18044 -0031 USA 905 - 884 -9774 (fax) 1- 610 - 559 -3608 (fax) 4901 Kesslersville Road viccanada @victaulic.com vital @victaulic.com Easton, PA 18040 USA EUROPE ASIA PACIFic 1 -800- PICK -VIC (1- 800 - 742 - 5842) 32 -9- 381 -15 -00 86-21-54253300 1- 610 - 559 -3300 32 -9- 380 -44 -38 (fax) 86 -21- 54253671 (fax) 1- 610 -250 -8817 (fax) viceuro @victaulic.be vicap @victaulic.com pickvic @victaulic.com UNITED KINGDOM MIDDLE EAST www.victaulic.com 44 (0) 1438741100 971 -4- 883 -88 -70 IIIIII IIIIIMIIIIIIIIIIIIIIIIIIIl1I 44 (0) 1438313883 (fax) 971 -4- 883 -88 -60 (tax) WCAS- 697KLG viceuro @victaulic.be UPDATED 4/06 40.62 3125 REV D ictauli�. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA _ s = - Spare Sprinkler Head Storage Cabinet Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by Specifications NFPA guidelines. The Spare Sprinkler Head Cabinets are avail- able in four configurations. Three head, six head, six head ESFR Material: and twelve head. All four styles are manufactured with "knockouts" Painted plain steel to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Finish: Each cabinet is finished with a red enamel finish. Each spare head Red enamel cabinet comes with a hinged door which remains closed to protect Styles: the spare sprinklers from the elements and features two holes on 3 Spare sprinklers, the back panel to allow for attachment to most surfaces utilizing the 1/2 or 3/4 appropriate fasteners. Not intended for exposed or harsh environ- 6 Spare sprinklers, ments. 1/2 or 3/4 Installation ed, installation is accomplished 6 Spare, ESFR, Select the correct Spare by inserting the correct fastener 1/2 , 3/4 or 1" Sprinkler Head Cabinet in in each of the two holes inside 12 Spare sprinklers accordance with the Automatic the cabinet, securing the cabinet 1/2 or 3/4 Sprinkler Systems Handbook. securely to the wall. The insert As per the 1989 Edition the the correct number and type of correct number of spare sprinklers in accordance with the sprinkler is as follows: "handbook ". *Final determination is subject to approval "0 -300 sprinklers, not less than 6 by the AHJ. 300 -1000, not less than 12 1000 or more, not less than 24. Stock of spare sprinklers shall include all types and ratings installed. "* Once the correct Spare Sprinkler Head Cabinet has been select- Fire Protection Products, Inc F P P I e 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011 -1541 ©2000 - 2007 Fire Protection Products, Inc (FPPI) For questions: 1 800 344 -1822 • 1 800 344 -3775 fax • www.fppi.com • I On ® ILPCBI £E VdS MEA: 276.99 -E CSFM: 7770-0531:113 SERIES 705W WITH WEATHERPROOF ACTUATOR ' 0,; A i [ The Series 705W butterfly valve features an approved weatherproof actuator housing approved for indoor or outdoor use It has a ductile iron body and disc with EPDM disc coating. The body is coated with a heat fused polyphenylene sulfide blend to meet FM requirements. Designed for fire protection services only Series 705W valve is UL Listed'. and FM Approved for 300 psi /2065kPa service. Contact Victaulic for details of agency approvals. WEATHERPROOF ACTUATOR Supervisory switches that monitor the valve in the fully open position for valves are available 2' - 12/65 - 300mm pre -wired (PW) OPTIONAL SUPPLY -SIDE TAP Series 705W valves are available with a 1" NPT supply side tap designed to allow direct water supply connection to Victaulic FireLock actuated fire protection valves See separate drawings below. This is an optional feature and must be clearly noted on all orders. • MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A -536, coated with polyphenylene sulfide blend Disc: Ductile iron conforming to ASTM A -536, various grades, EPDM coated. Disc Coating: • Grade "E" EPDM EPDM (Green color code) Temperature range -30 °F to +230 °F / -34 °C to +110 °C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL classified in accordance with ANSI /NSF 61 for cold +86 °F / +30 °C and hot +180 °F / +82 °C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Stem Bearings: Teflon impregnated fiberglass with stainless steel backing. Stem Bearing Nuts: Type 416 Stainless Steel Tap Plug: Carbon steel, plated. 0 -Ring: EPDM Bracket: Carbon steel, painted Actuator: • 21 - 8 "/65 - 200mm: Bronze traveling nut on a steel lead screw, in a ductile iron housing • 10 - 12/250 - 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing. JOB /OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com jctauled VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA IPS CARBON STEEL PIPE FIRE PROTECTION VALVES 1. U 1 0 Bu1e,r1.70v SERIES 705W WITH WEATHERPROOF ACTUATOR MATERIAL SPECIFICATIONS Handwheel: -• -- "7, ,.` : "' 1,- ,• iliRPIR) '. = IDNIs . anirem Cagi tiBTP 35161 301 21/2 - 4 30 125 65 - 100 76 2 200 125 - 150 114 3 8 2 160 mm 250 00 10 - 12 9 250 - 300 225 *VdS version not UL Listed, FM Approved or LPCB Approved. - • www.victaulic.com ‘ictaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY CI) 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA — • — IPS CARBON STEEL PIPE FIRE PROTECTION VALVES .1. U. .11. 0 . -- — – --- ----- -i, .,,,, -re, i• r ;,: .i -,, ., r , I '--> ' 'f''',: SERIES 705W WITH WEATHERPROOF ACTUATOR _ DIMENSIONS - cOus 441:), ILPCBI LISTED Aprx. Wgt. Size Dimensions - inches/millimeters Each s '. UMW s ..140.011kLC.61O , , , .: ..AVR. 1; - '' ' ,!..1:7,1 gEWilitg? - 1, 1' • , . , ' 1 ;5,, II ' ' • 1 11 1 ; , 1 ' . ' ' - 11 ' 2 ' , : , ''. .; Stgiti,4 , 2 ' OVIL aio - fivio 6 0' • , Pre 'ff' 0 Ir .1 . 'At'' !I '1;7'6 , r0' 1 Ts.r-A4' '' 21/2 2 875 377 876 ' 421 608 I 300 O00 * 075 , 83 _ 65 730 956 222 5 ' 106 9 i 154 4 762 , O0 * 191 38 3 000 377 876 421 608 300 000 * 075 83 76 1 mm 761 956 222 5 — 106 9 ■ 154 4 762 00 * 191 38 3 3 500 377 940 ' 008 421 608 300 000 * 075 89 80 889 956 238 8 , 20 , 106 9 154 4 , 762 00 * 191 40 4 4 500 463 1 10 84 , 007 601 698 300 073 113 149 100 114 3 , 117 6 275 3 18 152 7 - 177 3 762 185 287 68 _ - 5 500 5 88 12 38 0 43 6 01 , 8 57 4 50 21 0 _ 139.7 mm 139 7 149 4 314 5 109 152.7 1 2177 114 3 9 5 ' i __ - . . 5 5 563 , 588 12 38 043 601 857 4 50 21 0 141 3 149 4 125 - 314 5 ' 109 152 7 2177 114 3 _ _ , , 95 6 500 5 88 13 41 , 1 00 751 i 9 32 4 50 1 60 1.88 26 5 165 1 mm 165 1 149 4 340 6 , 254 190 8 1 236 114 3 406 , 478 120 _ 6 6 625 5.88 13 41 1 00 7.51 1 9 32 4 50 1 60 1 88 26 5 150 168 3 149 4 3406 254 - 1 236 7 114 3 ' 406 47,8 120 .._ 8 8 625 I 5.33 1 16 50 : 127 965 i 10 98 630 ' 000 068 430 200 21911 135 4 4191 i 323 245 1 1 278 9 160 0 00 * 173 ' 19 5 10 10 750 1 640 1914 172 12 20 i 16 19 900 i 800 _ 250 273 0 162 6 486 2 43 7 309.9 : 411 2 228 6 I _ 36 3 12 ' 12 750 6 50 21 54 2 66 14 25 ; 17 22 9 00 102 0 300 i 323 9 165 1 5471 676 362 0 , 4374 228 6 I _ _ 46 3 • On Centerline t These dimensions apply only to a Series 705W Butterfly Valve with a 1/2-inch NPT, supply-side tap 1. To prevent rotation of valves it is recommended that Series 705W be installed with Victaulic Style 07 Zero-Flex, Style 005 FireLock, Style 009/009V FireLock EZ, or Style HP-70 Rigid Couplings If Victaulic flexible couplings are used additional support may be required 2 Valve must not be installed with disc in full open position Disc must be partly closed so that no part is protruding beyond end of valve body 3. Victaulic grooved end butterfly valves are permitted for use with grooved end pipe (IPS) only Not permitted for use with plain end (IPS) pipe. 4 Series 705W valves are designed for ambient weather conditions as opposed to submersible service. /Ph 011a - - - rqh —_,-c-, rt1=E „ ittiy , 0 -Rftr-v wiAm m1-4,:. 0 ..4 II iliVi In lb. • ti - 1111: w NPT Suppiy Tap Ilr , _ l e 1 Supply Tap , I 1111q111111 1,1":1 L Ilibank II , :Will 410 VW II N 1111 II ll III IIIII LL E L F F 1 P 1 2½ - 4-INCH/65 - 100-MM SIZES 5 - 12-INCH/125 - 300-MM SIZES www.victaulic.com jctaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA ......— IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES I U. I 0 SERIES 705W WITH WEATHERPROOF ACTUATOR DIMENSIONS — , VdS o ' o E . Aprx. Wgt. Size Dimensions - inches /millimeters Each 7 ' I o r ' a - -Yom" _ _ . , - • p - - -. , -' '; . _ a f"L4t1r !I , , ,;!I 1 ''I t 1 Grew , ;, € , 9s' l °`vim rlu 1 °O° 'VT .i ,V. _ _'ice _. 2'h 2875 377 876 _ 421 608 4,92 000" 075 83 65 730 956 2225 1069 1544 125 00' 191 38 76,1 mm 3000 377 876 — 421 I 608 492 000' 075 83 761 956 222.5 j 1069 1544 I 125 00` 191 38 3 3500 377 940 008 421 608 492 000' 075 89 80 889 956 2388 20 1069 E 1544 125 00' 191 40 4 4500 463 1084 007 601 698 I 492 073 113 149 v 100 _ 1143 1176 { 2753 i 18 1527 1773 125 185 287 68 1397mm ( 5500 588 1238 043 601 857 787 210 1397 _ _ I 494 3145 109 1527 2177 200 95 5 5563 1 588 1238 043 601 857 e 787 I 210 125 _ ' 14 149.4 3145 i 109 1527 2177 200 95 165 1 mm 6 500 5 88 ( 13 41 1.00 751 9 32 I 7 87 1 60 1 88 26 5 1651 1494 3406 25.4 1908 2367 200 406 478 120 -I i 6 6625 588 1341 100 751 932 787 160 188 265 150 9 168 3 149 4 340 6 25 4 190 8 236.7 200 40 6 i 47 8 12 0 ___ — 8 8625 533 1 1650 127 I 9,65 1098 984 000" 1 068 430 200 2191 1354 4191 323 _ I 2451 278.9 250 00' 173 195 10 10 750 6 1914 1 72 12 20 1619 9 84 _ 80 0 250 273 0 i 162 6 486 2 43 7 309 9 411 2 250 i 36-3 12 12 750 € 6 50 i 21 54 2 66 9 14 25 17 22 I 9 84 — — 102.0 300 f 323 9 ,, 165 1 i 5471 676 362 0 4374 250 46 3 *On Centerline * These dimensions apply only to a Series 705W Butterfly Valve with a'/ -Inch NPT, supply -side tap 1 To prevent rotation of valves it is recommended that Series 705W be installed with Victaulic Style 07 Zero - Flex Style 005 FireLock, Style 009/009V FireLock EZ, or Style HP -70 Rigid Couplings If Victaulic flexible couplings are used. additional support may be required 2. Valve must not be installed with disc in full open position Disc must be partly closed so that no part is protruding beyond end of valve body. 3 Victaulic grooved end butterfly valves are permitted for use with grooved end pipe (IPS) only Not permitted for use with plain end (IPS) pipe. 4 Series 705W valves are designed for ambient weather conditions as opposed to submersible service Min " ter ! - o - (1A r*- S D J B �I • / r • s u1/2r; Tap h r B . I- SuPPII I I [ 11 ,�11 W II II' N �I� III 1111II II E r = 1 A E P 1 F � A E P-1-1 21/2 - 4- INCH /65 - 100 -MM SIZES 5 - 12- INCH /125 - 300 -MM SIZES www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA ctaUllc° • IPS CARBON STEEL PIPE FIRE PROTECTION VALVES i U. 113 . _ . - AreLock® i Valve SERIES 705W WITH WEATHERPROOF ACTUATOR ,, ------ • PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 705W in equivalent feet/meters of straight pipe. Size Size . . . .,. . - , '-' , .r".2.1• - " , 4 4 ' , ", - ' 4 -,,, ,'', ),--, , , , .7'. ctua • "'" ' - ' , g' ' ' 1,'Xili0,;* ,, L 4, im 4 k , 0.5 ' 1V.x' , ',•1 7 ev- , kf,'''' ,:*. • ‘ i - ...,,,-,,,.,„,.. ,140411.4,.., +PAAti.{..dt; litif tt , t 4, A 41. ,- 4 r'' ,14 :Inif . . '' 4 4 4 .4 1 10,1 44' ' '+:,' 4 `.4 * '^ '','•:., .tftV ' . t ,1100 , - "4443' firt ::.'A74 C-„. itititiik IV , tIF;: fritAVA" 7% ' itItl limz. 44'4i: 2½ '' 2 875 5 6 500 8 165.1 mm 73 0 1 6 165 1 , 25 3 000 5 6 6 625 ' 8 761 1 6 „ ' i50J 168 3 i 25 .„--,,---- 3 4: 3 500 5 ' '8 — 8 625 11 88 9 16 - 200 2191 , 34 4 500 12 li ' ' 10 ' ', 10 750 ' 12 2 ', .iob„ ,-;: ...,. 114 3 37 ,,,`. , . 250 , 273 0 37 5 500 1 12 :12 1 12 750 1 14 139 7 37 ', 300 323 9 43 5 5.563 12 125 •,'. , =, 141.3 37 MAXIMUM WORKINGS . . • . PRESSURE RATINGS Size Maximum Working Pressure by Agency lif 1 :9• .11 : - 1.: ..'„, go'i ,•••;''' ,: .t:V{••;•.t A ..i. tg.•. g4.44;" -.," . IPI A =14 1.!z,!t ' it t '',-1WVI■ki '..':'...'":'" =';'r ' - ' ' '=';r-",'" ' -'),.' 'N4411/ '1.'.: 7•': : irt ' .) ' 4iRchest.,,k.0 .„, • ,. 4 .,• Ftv),.4..a.;. - „,-,,,..7., tov ,,..., ,.._,.....: mm „MAI Pstflin ,,,,,,,. ,,, PSI .,...',..:,1-7; BAR A. .8MR Atit 2 'ii 2.875 300 1 , , 300 : ',.', -,,,..- 20 16 65 , '; ".`.!', 730 1 76.1 mm 3.000 300 20 I 16 '.-,, ---- 3 , ,, '.4. , 3 500 300 ,,, ',,, , 300 20 16 80 ''.- • 889 , ,,'••:".'•.., --' ' ::::_`.; , . .., .• i''' i ;-: - _ , 4 500 300 ',',,? , 20 300,' ; .i , 16 , 114 3 , * 1 5 500 300 1 ' , :, 360, .; :1 20 i 16 139 7 '5 ; , : 1'f' 1 5 563 300 1 , 300 , ,, i 20 16 '125 , ; ,','.::' 1 141 3 ', •, ' 165.1' '', ' ' i 6 500 300 , : 300 ; 2 -; 20 16 ',- : ‘, , -„,'',„'• ''' 1 165 1 ' -6' = • i 6.625 , 300 ' '300 ' ; 20 16 7, 8 "— 8292 65 20 16 • , ' : 11 1 300 , 300, ' ,,, 10 750 ' 300 ,. 20 16 '., ,•- 250 ' 273 0 . , , . — 12 750 ; 00 300 , - 300 ,,,.' 20 , 16 3 ' , . - - • www.victaulic.com . jctaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA IPS CARBON STEEL PIPE FIRE PROTECTION VALVES 1 U. I 0 < t � Ii P u I „t ,. =" 'rr 'r S;V . g SERIES 705W WITH WEATHERPROOF ACTUATOR PERFORMANCE C values for flow of water at +60 °F / +16 °C with a fully open valve are shown in the table below For additional details, contact Victaulic. Formulas for C Values: LsP = Q Where: C2 (-.). Flow (GPM) AP = Pressure Drop (psi) Q = C x AP C = Flow Coefficient Size C, Size C - ' Size ' C,, )„ Achi I i +s '.' KS :f '. An ai - 1i ` °: '�. '' i s -[ '-'..::'„r! , 1 + No In a Out id- 1 a i, ti mina ' ' r '0u de' - #.,1 `s,, 1 `� $0 1 Doti :" "}Size Diameter', 'S r' tDiameter ,. i'r S4 Sme r' 1 .�'-�Tml w� Inches, , yam ; 1f"has :•arches �, .y 1 I ' ,� . , e rr ""S . . sire . « It1ll0pen} A., m `;' fnut7 ,- W6'zI `.) tssii ,: 1 ;F SOLOS ar-0a Ili 2 ,5 2 875 5 500 j 8 8 625 325 139.7, mm 1150 3400 65 73 0 139 7 200 i 2191 3 000 5 5.563 10 B 10 750 761 mm 761 325 125 1413 1150 5750 250 2730 3 3500 6500 12 12750 80 88 9 482 165.1 "mm 165 1 1850 300 323 9 8300 4 4 500 6 6 625 100 i 114 3 600 150 168 3 1850 Formulas for K Values: AP = Q Where: K Q =Flow (- ) Q = I(, x .S.P AP = Pressure (bar) K = Flow Factor Size K Size K„ Size K„ ..1., `� ° ACC '. t " T , � Act - ' f " A41U at ` i. , i f ,,,,, .r Nom mal Duiside,,F z orrunai . . Out 1 ` , ' 4 na Outs de g In D tetL ' ' f iDamete S ta *1,7,' f. ' , timePer rr . -, t . i iT ' ! 'ic,g E .. aaefies „ inf}he t ,� a limhe8 `.; goy" _ . a t}. Open ., t i rCr`d`lu 0 ni; s` : m ' I_ ,fi A r o P. it) 21 I 2.875 5 500 8 8 625 65 73.0 280 139 7 mm 139 7 995 200 I 2191 2940 3 000 5 ,. 5 563 10 0 750 --- - 761 mm 280 995 ' 4975 76.1 125 - 141 3 250 i 273 0 " 3 3 500 - 6 500 12_ ., 12 750 _ 415 165 1 mm 1600 7180 80 . 88 9 165 1 300 " s 323 9 4 j 4500 6, , 6625 100 i 114 3 520 150 168 3 1600 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA iCtaUIIL• • IPS CARBON STEEL PIPE FIRE PROTECTION VALVES J. U o J. 0 A L ® Butterfly Valve SERIES 705W WITH WEATHERPROOF ACTUATOR SWITCH AND WIRING 1 The supervisory switch contains two, single pole, double throw, pre -wired switches 2 Switches are rated: 10 amps ® 125 or 250 VAC /60 Hz 050 amps © 125 VDC 0.25 amps © 250 VDC 3 Switches supervise the valve in the "open" position 4 One switch has two #18 MTW wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 MTW wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed 5 A #14 MTW ground lead (green) is provided. Switch #1 = S1 For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction Normally Closed: (2) Blue S1 Common: (2) Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common. Yellow with Orange Stripe UL LIS ILU JUNCTION BOX FIRE ALARM CONTROL PANEL TO END OF -LINE RESISTOR, CONDUIT SUPERVISORY OR NEXT INDICATOR CIRCUIT r ► � t l � SWITCH 1I��aI M N / CONTACT RATING CONDUIT CONNECTORS , IOA AND • 250VA OVAC 0 55 AT 125 VDC, 0 75Ai 250 VDC 4 4 WIRE NUTS BELL OR VOLTAGE SOURCE HORN Switch 2 leads per terminal Switch 2 t teed per terminal NOTE: The above diagram shows a connection between the common terminal (yellow — S1 and yellow -with- orange stripe — S2) and the normally closed terminal (blue — S1 and blue -with- orange stripe — S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out Cap off any unused wires (e.g. brown with orange stripe) Only S1 (two leads per terminal) may be connected to the fire alarm control panel The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC) www.victaulic.com ,ctc'AQJO1c' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA, ri SERIES 705W WITH WEATHERPROOF ACTUATOR WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions Victaulic reserves the right to change product specifications designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the installation sheet included with the valve Verify you have the latest revision by visiting our website at www.victaulic.com. Further reference can be found in the 1 -100 Victaulic Field Installation Handbook III II III III I11111111111III I11III111111III WCAS- 6ZAQT8 For complete contact information, visit www victaulic corn 10.18 2466 REV G UPDATED 7/2007 jctaulic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA IPS CARBON STEEL PIPE - FIRE PROTECTION VALVES 10.17 VICTAULIC` IS AN ISO 9001 CERTIFIED COMPANY Series 728 FireLock® Ball Valve PRODUCT DESCRIPTION The Series 728 FireLock'" valve is a standard port, end -entry valve that is UL /FM rated for 350 psi (2410 kPa) service in all sizes. e K ,l i Available with grooved or threaded ends (NPT), the valve body and gearbox are brass die cast The ball is chrome plated brass with a ' .A. <`, / brass stem TFE seats aid ease of operation and provide a '' ' ' "'"" / corrosion -free seat The streamlined design provides excellent flow ', �� ` �� _ , characteristics, which exceed UL Specification 1091 and FM o ® r.,,, ` 3 Approval Standard 1112 The valve is approved for indoor and outdoor use 41> Mtf, ,,, , A See Victaulic , .� . c. publication 10 01 t for details " NPT available in 172 - 2" grooved version only DIMENSIONS (F- K-►I J ILK-" < H J I H MI -NE/:- Ff.. - 1 n 1 ��r ' ,i0(64 1 - 1 - - r - - i e f :„I'I l _ _ C (4)1°) • + L , . =��1I�_ t A F > A 4 F --u Grooved X Grooved Threaded X Threaded Dimensions - Inches/millimeters Aprx. SIZE - Wgt. Each Nominal E to E Height Lbs. Inches A B C D F G H J K L 0 kg 1 Thd X Thd. 2 84 5.61 0.93 1 22 1.87 2 27 3.39 5.62 1 86 1.42 2.75 5 1 72 143 24 31 48 58 86 143 47 36 67 2,3 1 Thd. X Thd 3 31 6 04 1 15 1 53 2 30 2.47 3.39 5.62 1 86 1 65 2 75 5 8 84 153 29 39 58 63 86 143 47 42 67 2,6 1 Thd. X Thd 3.66 6 42 1 35 1.71 2.66 2.66 3 39 5 62 1.86 1 83 2 75 6.6 92 163 34 43 68 68 86 143 47 47 67 3,0 2 Thd. X Thd. 4 33 7.15 1.71 2 07 3 40 3.05 3.39 5 62 1 86 2 16 2.75 8 5 110 182 43 53 86 77 86 143 47 55 67 3,9 1 Giv. X Grv. 7.25 6 25 1 15 1 67 2.30 2.58 3 39 5 62 1 86 3 19 2.75 7.5 184 159 29 42 58 66 86 143 47 81 67 3,4 1 Gry X Gry 725 675 1 35 189 271 280 339 562 186 319 275 85 184 171 34 48 69 71 86 143 47 81 67 3.9 2 Grv. X Grv, 7 25 7.50 1,71 2 25 3 16 3 50 3.39 5 62 1 86 3.19 2 75 10.5 184 191 43 57 80 89 86 143 47 81 67 4,8 PERFORMANCE SIZE Equivalent' SIZE Equivalent' Nominal Inches Feet/meters of Pipe Nominal Inches Feet/meters of Pipe 1 Thread X Thread o 2 1 Groove X Groove o 4 1 Thread X Thread 0,3 1 /2 Groove X Groove 0 ,3 1 Thread X Thread o s 2 Groove X Groove o a 2 Thread X Thread 0 5 0,2 'Caicuiatod using Hazen - Williams with C =120 ® REGISTERED TRADEMARK OF VICTAULIC - 0 COPYRIGHT 2005 VICTAULIC - PRINTED IN U S.A. - SKU rIWCAS- 6E7PM4 2226 REV C United States • Phone' 1- 800 - PICK -VIC (1- 800 - 742 -5842) • Fax: 610 - 250 -8817 • e -mail pickvic @victaullc corn Canada • Phone 905- 884 -7444 • Fax 905- 884 -9774 • e -mail viccanada @victaulic corn Europe • Phone' 32 -9- 381 -1500 • Fax: 32 -9- 380 -4438 • e -mail viceuro @vlctaulic be UK • Phone 44(0)1438741100 • Fax 44(0)1438313883 • e-mail viceuro @victauiic.be , ��� �', �© Central and South America • Phone. 610 - 559 -3300 • Fax: 610 - 559 -3608 • e -mail vital @victaullc corn Australasia • Phone. 85 -21- 58855151 • Fax 86 -21- 58851298 • e-mail viran @viriaulic rem - ___V__ ` 1 p.47, . - SWITCH AND WIRING -- - Supervisory Switch The supervisory switch contains two, single pole, double throw, pre -wired switches Switches are rated 10 amps 0 125 or 250 VAC /60 Hz 050 amps @ 125 VDC 0.25 amps @ 250 VDC 26 amps @ 24 VDC Supervisory Switch Wiring A Pre -wired Switches (1) Switches supervise valve in "open" position (2) One switch has two #18 MTW wires per terminal, which permit complete supervision of leads (refer to diagrams and note below). The second switch has one #18MTW wire per terminal This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed (3) A #14MTW ground lead(green) is provided Switch #1 51 Switch #2 S2 Normally Closed (2) Blue SI Normally Open (2) Brown Common (2) Yellow Normally Closed Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe UL LISTED JUNCTION BOX 7 FIRE ALARM TO END EXT INE RESISTOR, % BOX CONTROL PANEL OR NEXT INDICATOR SUPERVISORY ` CIRCUIT / CONDUIT ` , ±: id SWITCH CONTACT RATING ..111 NM 10A AT 125 AND ' • 250VAC, _ i� AT 125 VDC, _ E NPT� 0 25 1 025 AT 250 VDC BELL aim CONDUIT CONNECTORS % OR , 1 VOLTAGE SO URCE HORN Switch 1: 2 leads per terminal WIRE NUTS Switch 2:1 toad per terminal NOTE: The above diagram shows a connection between the common terminal (yellow -S1) and yellow - with- orange stripe -S2) and the normally closed terminal (blue -S1 and blue -with- orange stripe -S2) In this example, the indicator light and alarm will stay on until the valve is fully open When the valve is fully open, the indicator light and alarm will go out. Cap off any unused wires (e g. brown and brown with orange stripe) MATERIAL SPECIFICATIONS ' Valve Body: Bronze ASTM B -584 Alloy 844 Ball: Chrome Plated Brass Stem: 316 Stainless Steel Seat: (TFE) tetrafluoroethylene Stem Nut: Brass ASTM B -16 C36000 Quadrant Gear: 316 Stainless Steel Main Stem: Brass ASTM B16 C36000 Worm Gear: AISI 1144 Steel This product shall be manufactured by Vlctaullc Company All products to be installed in accordance with curient Victaulic installation /assembly instructions Victauilc reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations 2 Series 728 FireLock Ball Valve 4 - 1I � '`, � 4 5,,�a .: i 1 . � . �.� ;: M 1�A . . . „ , i..a kor • ke-17 , ,. . i _ . s , , mii =oh , , ,, ' V,R19, i , A : . :op, :i,..„:„, ,:,,,. TE - TAN UK IN ,y.v. ,,_______1,,, ., ,.,. . z, ,,, 4:7_,._/„._. Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve C 0 us APPROVED 3/ 4 I 1 n -A 1 11 1 1 2 n ; s5 ' , ix 2} . �' ,' TEST F ,. j tH { "' ' 0,p a v _ Y ausn r' / "t t" X t, $tt p 7 ; � .. Y 4a4A t�` 0 _ � ,,L, t SIZE IN. MODEL 1011 ' , .. • The AGF Manufacturing Inc. Model 1011A TESTANDRAIN matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system, with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. • The Model 1011A complies with the requirements of NFPA -13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). • The Model 1011A TESTANDRAIN is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. • Available in a full range of sizes from 3/4" to 2" NPT and BSPT, with all specifiable orifice sizes 3 /s" (2.8K), 7 /16" (4.2K), 1" (5.6K), 17 /32" (8.0K), 5 /e" (11.2K) (ELO), 3/4" (14.0K) (ESFR), and K25 as required by NFPA 13, 2007 Edition (see reverse). • The included UL/FM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. • Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the difficult problem of providing the relief valve with a convenient drainage - piping outlet. • Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. • A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent unintentional alarm activation. NOTE. It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. Reliability,, Versatility Code Compatibility T' ```� 'j Model 1011A � 6 ' A t ' � 14 `' fi r ' �' ' .ii C us ® TEST DRAIN ,:: ,,J, � ' ` Model 1011A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve , a t, APPROVED Factory Rated at 175 PSI with other settings available DIMENSIONS MODEL 1011A - FRONT VIEW Orifice Size Available: 3 /8 ", 7 /16 ", 1 /2 ", 17 /32 ", ELO ( /6") ", ESFR ( ") ", & K25 "" A SIZE A B C D E F G H E 1 j INLET ++ 3 7 1 2 3 3 1 4 6 TO F '+' 1 /4 (191 mm) (37.5 mm) (57 mm) DRAIN u�11 n ff ( ) ( ) (93 mm) (86 mm) (46 mm) (117 mm) (162 5 mm) H � ��C J \ . .,,I� � l a 1 79/16" 11/2" 2 3 3 1 4 63/ 1 i%��, m (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4" 715A6" 111/16" 29/16" 41/ 35/ 1 5 5 I 11 (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) --- 11/2" 8 1 3 5 3 2 /a" 8 10 MODEL 1011A - PLAN VIEW (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2 .. 8 1 3 5 3 2 8 10 I A --al (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) I O *Available on 1 to 2" size units only **Available on 1 and 2" size units only To e u) � � II DRAIN D + �� gook THE MODEL 1O11A PROVIDES ALL OF THE FOLLOWING... f 0 % of II From the 2007 Edition of NFPA 13 4 O T Chapter 8.16.2.4.1" Provisions shall be made to properly drain all parts of the system. u Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s)— & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. MATERIALS Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling Handle: Steel the flow of the drain. Stem: Rod Brass Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into Ball: C.P. Brass a drain capable of accepting full flow... using an approved sight Body: Bronze test connection containing a smooth bore corrosion - resistant Valve Seat: Impregnated Teflon® orifice giving a flow equivalent to one sprinkler... Indicator Plate: Steel Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Relief Valve: Bronze Chapter 8.17.4.2.4 shall be permitted to be installed in any location... downstream Bypass Fittings: Brass of the waterflow alarm. Bypass Tubing: Nylobraid Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion - resistant orifice, APPROVALS to provide a flow equivalent to one sprinkler... UL and ULC Listed: (EX4019 Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less & EX4533) than 1", at least one of which shall be brass. FM Approved Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve NYC -BSA No. 720 -87 -SM set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3" A relief valve of not less than 1 /2" in size shall be provided on the x + «,k s�1 r. « discharge side of the pressure- reducing valve set to operate at a ; * « «� ;. pressure not exceeding 175 PSI. '� r�+� Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the MADE IN U.S.A. (pressure relief) valve USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name: 100 Quaker Lane, Malvern, PA 19355 T: 610 - 240 -4900 / F: 610 - 240 -4906 Architect: E -mail: info@testandrain.com Engineer: www.testandrain.com Contractor: ES- A -4000B Series 4000B A M E S FIRE& WATERWORKS Reduced Pressure Zone Assemblies Sizes: 1/2" — 2" (15 — 50mm) R4 1^ ti Li I y 4 , . 2" (50mm) 4000B -HC J '6 ' '/a" (15mm) 4000B Features Series 4000B Reduced Pressure Zone Assemblies are designed to protect • Single access cover and potable water supplies in accordance with national plumbing codes and wa- modular check construction ter authority requirements. This series can be used in a variety of installa- for ease of maintenance tions, including the prevention of health hazard cross connections in piping • To entry systems or for containment at the service line entrance. p ry - all internals immediately accessible This series features two in -line, independent check valves, captured springs • Captured springs for safe and replaceable check seats with an intermediate relief valve. Its compact maintenance modular design facilitates easy maintenance and assembly access. Sizes 1 /2 "- 1" (15 -25mm) shutoffs have tee handles. • Internal relief valve for reduced installation clearances • Replaceable seats for Specifications economical repair p • Bronze body construction for A Reduced Pressure Zone Assembly shall be installed at each potential durability -' /z" to 2" (15 -50mm) health hazard location to prevent backflow due to backsiphonage and /or backpressure. The assembly shall consist of an internal pressure differential • Ball valve test cocks - relief valve located in a zone between two positive seating check modules screwdriver slotted -1/2" to 2" with captured springs and silicone seat discs. Seats and seat discs shall be (15 -50mm) replaceable in both check modules and the relief valve. There shall be no • Large body passages provides threads or screws in the waterway exposed to line fluids. Service of all inter - low pressure drop nal components shall be through a single access cover secured with stain- • Compact, space saving design less steel bolts. The assembly shall also include two resilient seated isolation • No special tools required for valves, four resilient seated test cocks and an air gap drain fitting. The as- servicing sembly shall meet the requirements of: USC Manual 8th Editiont; ASSE Std. 1013; AWWA Std. C511; CSA B64.4. The assembly shall be an Ames Com- pany Series 4000B. Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without pnor notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com Materials Pressure — Temperature Bronze body construction, silicone rubber disc material in the Suitable for supply pressures up to 175psi (12.06 bar) first and second check plus the relief valve. Replaceable poly- and water temperature to 180 °F (75 °C) continuous. mer check seats for first and second checks. Removable stain- less steel relief valve seat. Stainless steel cover bolts. Standardly furnished with NPT body connections. For optional Available Models bronze union inlet and outlet connections, specify prefix U Suffix: (1/2" - 2 ")(15- 50mm). Series 4000B furnished with quarter turn, B - quarter -turn ball valves - full port, resilient seated, bronze ball valve shutoffs. LBV - less ball valves Standards LH - locking handle ball valves (open position) AWA C511 -92, USC Manual 8th Edition, IAPMO File No. 1563 SH stainless steel ball valve handles HC - 21/2" inlet/outlet fire hydrant fitting (2" valve) Approvals S - bronze strainer 4�pS31fj�o Prefix: 855E c SA us iUL DS U - union connections 1013 B64.4 3 /a" - 2" (20 -50mm) (LBV models only) Approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California. Approval models QT, U. IMPORTANT: Inquire with governing authorities for local installation requirements. Weights — Dimensions I Eli I. • y. M 4 A Suffix HC - Fire Hydrant Fittings dimension "A" = 25 (637mm) MODEL SIZE (DN) DIMENSIONS' - -: STRAINER DIMENSIONS - +'' WEIGHT A in mm in. mm in mm in. mm in mm In mm in. mm in. mm lbs. kg. 4000B'* 1/2 15 10 250 4% 117 3 86 1 32 512 140 3 76 2 51 4.50 2.0 40008 M3*` 3 /4 20 10% 273 5 127 312 89 11/2 38 6% 171 3 84 2 59 5.75 2.6 4000B M2** 1 25 16% 425 51/2 140 3 76 21/2 64 91/2 241 41/2 114 2 59 12.25 5.6 4000B°° 1 32 17 44 116 150 3 89 21/2 64 11% 289 5'/ 130 3% 79 14.62 6.6 4000B ** 1 40 17'/6 454 6 150 31/2 89 21 64 11' /8 283 5 149 3% 95 16.32 7.4 4000B ** 2 50 21% 543 7% 197 4 114 31/4 83 131/2 343 6 157 4 124 30.00 13.6 Strainer sold separately * *Approved by the Foundation for Cross - Connection Control and Hydraulic Research at the University of Southern California. 2 Capacity Performance as established by an independent testing laboratory. *Typical maximum system flow rate (7.5 feet/sec., 2.3 meters /sec.) kPa psi ' /a" (8mm) kPa psi 1" (25mm) H 138 20 ' 207 30 0 J 117 17 J 172 25 - d m 96 14 3 138 20 H 76 11 - S 103 15 a` 69 10 CL 35 5 AP 0 .25 .50 .75 1 1.17 gpm 34 5 0 .95 1.9 2.9 3.8 4.5 Ipm 0 0 -- 0 5 10 20 30 40 50 60 70 80 gpm Flow Rate AP 0 19 38 76 114 152 190 228 266 304 Ipm 7.5 15 fps 2.3 4.6 mps Flow Rate kPa psi 3 /e" (10mm) kPa psi 11/4* (32mm) H 138 20 H 01 172 25 p117 17 J 138 20 y 96 14 E 103 15 ' y 76 11 ' 55 8 2 69 10 a 35 5 a. 34 5 AP 0 .25 .50 .75 1 1.25 1.50 2.5 3.1 gpm 0 0 - 0 .95 1.9 2.9 3.8 4.8 5.7 9.5 11.8 Ipm 0 20 0 0 g(L)1 ggm Flow Rate AP 0 38 10 76 11 1 190 50 228 60 266 70 3 Ipm p 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps Flow Rate kPa psi '/2* (15mm) kPa psi 11/2" (40mm) * H 172 25 H 207 30 o 138 20 o 172 25 103 15 i 138 20 co 69 10 H 103 15 d 69 10 k 35 5 , a 34 5 AP 0 1 2.5 5 7.5 10 12.5 15 gpm 0 0 0 3.8 9.5 19 28.5 38 47.5 57 Ipm pp 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm 5 7.5 15 fps 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 1.5 2.3 4.6 mps 5 7.5 10 15 fps Flow Rate 1.5 2.3 3.0 4.6 mps Flow Rate psi * 3 /a" (20mm) 2" (50mm) kPa kPa psi kPa psi * 207 207 30 0 165 24 H 172 25 1 124 18 - - J 138 20 H 83 12 e 103 15 .-----------"g .-----------"g / - g 41 6 u 69 10 a 0 0 0 34 5 a 0 0 0 2 6 10 14 18 22 26 30 34 38 42 46 gpm APO 20 40 60 80 100 120 140 160 180 200 gpm �P 0 7.6 23 38 53 68 84 99 114 129 144 160 175 Ipm 0 76 152 228 304 380 456 532 608 684 760 Ipm 7.5 15 fps 5 7.5 10 15 s 2.3 4.6 mps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate 3 • For additional information visit our web site at: www.amesfirewater.com A M E S ' 9001 FIRE &WATERWORKS A Division of Watts Regulator Company www.amesfirewater.com CERTIFIED 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916 - 928 -0123 • Fax: 916 - 928 -9333 ES- A -4000B 0625 ©Ames Fire & Waterworks, 2007 _`s .0 f 150 � ; sir ;,,,;PsIN.1400 / , ",,A.,,,,. f l ; = SPRINK R 200 d ,' WAT Sprinkler Gauge :II —50 ` 250 : . a 300 , s N.Yitx „w \ sra' - = u.CY e, 'SA -- , Applications • Fire sprinkler systems I 1 A. 1 f • Suitable for all media that will not ' obstruct the pressure system or i attack copper alloy parts . i . i f I . Special Features �� U 1T • UL- listed (UL -393), United States vrCSq) and Canada Dimensions - _______... = . - T • Factory Mutual (FM) approved • Reliable and economical Size A B C E L T W Wei • ht 4” mm 100 83.5 30 11.5 3.75 14 in 4.0 3.29 1.18 0.45 0.15 1/4" 0.55 0.35 lb. Standard Features Design EN 837 -1 & ASME B40.100 Bourdon Tube Optional Extras Material: copper alloy C -type (not all options are UL or FM approved) Sizes 4" (100 mm) Pressure Connection • Brass restrictor Material: copper alloy • Friction -fit cover ring Accuracy class 1/4" NPT lower mount (LM) (requires steel case) ± 3/2/3% of span (ASME 840.100 Grade B) Movement • Glass window Copper alloy (requires steel case & friction ring) Ranges • Black- painted steel case 0/80 psi, retard to 250 psi (air) Dial 0 /300 psi (water or air) White aluminum with stop pin; • Stainless steel case black and red lettering • Special case colors Working Pressure • Nickel- plated connection Steady: 3/4 of full scale value Pointer Black aluminum • Custom dial layout Fluctuating: 2/3 of full scale value Short time: full scale value Case • Special threaded connection Black polycarbonate • Custom dial layout Operating Temperature • Other pressure scales available: Ambient: -40 °F to 140 °F Window ( -40 °C to 60 °C) Snap -in clear polycarbonate bar, kPa, MPa, kg /cm2 and dual scales Media: 140 °F ( +60 °C) maximum Approvals Temperature Error UL listed (UL -393) Factory Mutual Additional error when temperature changes from reference tem- APPROVED perature of 68 °F (20 °C) +0.4% for every 18 °F (10 °C) rising or falling. c ®us Percentage of span. -, j LISTED Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011 -1541 ©2008 Fire Protection Products, Inc (FPPI) FPPI . P „ For questions: 1 800 344 -1822 • 1 800 344 -3775 fax • www.fppi.com ' ' POT VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD UL, CUL and CSFM Listed, FM Approved,LPCBApproved,For CE Marked (EN12259 -5) / VdS Approved model use VSR -EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15 -38 LPM)- UL Maximum Surge: 18 FPS (5.5 mis) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at125 /250VAC 2.0 Amps at30VDC Resistive * "' 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA4 /1P54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die -cast housing when used with appropriate conduit fitting. " A WAAf ; V IN G • Temperature Range: 40 °F - 120 °F, (4.5°C - 49 °C) - UL lei I 171 • Non - corrosive sleeve factory installed in saddle. • installation must be performed by qualified personnel and in Service Use: accordance with all national and local codes and ordinances. Automatic Sprinkler NFPA -13 • Shock hazard. Disconnect power source before servicing. Serious One or two family dwelling NFPA -13D injury or death could result. Residential occupancy up to four stories NFPA -l3R • Risk of explosion. Not for use in hazardous locations. Serious National Fire Alarm Code NFPA -72 injury or death could result. Optional: Cover Tamper Switch Kit, Stock No. 0090148 General Information Drain the system and drill a hole in the pipe using a hole saw in a slow The Model VSR is a vane type waterfiow switch for use on wet speed drill. (see Fig. 1) sprinkler systems. It is UL Listed and FM Approved for use on steel Clean the inside pipe of all growth or other material for a distance equal pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). to the pipe diameter on either side of the hole. LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Roll the vane so that it may be inserted into the hole; do not bend or Information chart. crease it. Insert the vane so that the arrow on the saddle points in the The VSR may also be used as a sectional waterfiow detector on direction of the waterfiow. Install the saddle strap and tighten nuts large systems. alternately to required torque. (see Fig. I). The vane must not rub the The VSR contains two single pole, double throw, snap action switches inside of the pipe or bind in any way. and an adjustable, instantly recycling pneumatic retard. The switches Specifications subject to change without notice. are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period Ordering Information of time necessary to overcome the selected retard period. Nominal Pipe Size Model Part Number Enclosure 2" DN50 VSR - 2 1144402 The VSR switches and retard device are enclosed in a general purpose, die -cast housing. The cover is held in place with two tamper resistant 2 I/2" DN65 VSR -2 1/2 1144425 screws which require a special key for removal. A field installable 3" DN80 VSR - 1144403 cover tamper switch is available as an option which may be used 3 1/2" - VSR - 1/2 1144435 to indicate unauthorized removal of the cover. See bulletin number 4" DN100 VSR - 1144404 5401 103 for installation instructions of this switch. 5" - VSR - 5 1144405 Installation: See Fig. I These devices may be mounted on horizontal or vertical pipe. On 6" DN150 VSR 1144406 horizontal pipe they should be installed on the top side of the pipe 8" DN200 VSR - 1144408 where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146 -4161 • Phone: 800 - 325- 3936 /Canada 888 - 882 -1833 • www.pottersignal.com PRINTED IN USA MFG #5401146 - REV II PAGE 1 OF 3 12/07 /v l6YM. PO VANE TYPE WATERFLOW , e The Symbol of Protection ALARM SWITCH WITH RETARD COUR TAMPER SuOTC11 Fig. 1 Fig. 2 Switch Terminal Connections IDSTMENT ,� _ -- _ - --- Clamping Plate Terminal THE RETARD DEL. OwT BE ADJUSTED RS ROTATING T11E NG ADJUSTMENT 90SEC RNORE F TIMn DEL. /i' Iii PAP 4 MIN TM um THE UID fI EXTENDED E OVER FOR RESET AT THE E MML\IUM REQUIRED TO TO PRE SHO HO PREVENT I I tTF DED PERIOD OF TLY.UL L FALSE ALARMS :/\ I ' _ j: i TIMA-IkVI*Fil / , L• r '� `\ = \ ADAPTER AUTE0. `i � r` TIGIITR.t'L�M1IITS M -Oil it `. ' %10e.° ALTEATEI V ! ���`� mm xlmm MAA DNS° ONLY s ,. 41 ali ��l�� '•� USE (2) 5180162 ADAPTERS AS SHOWN AUOVI. OJ,i>UrV nN V2 GO � / � AIOUN - I ON PIPE SO "�'� �° "�'" °" AWARN � An uninsulated section of a single conductor P S lipp L should not be looped around the terminal and ROLL PADDLE IN OPPOSITE DIRECTION serve as two separate connections. The wire must OF WATERFLOW be severed, thereby providing supervision of the OF MATERFLOW OOCECTION Of connection m the event tha the wire beco WATERFLOW \\ I dislodged from under the terminal Failure to sever the wire may render the device inoperable \' _ risking severe property damage and loss of life. �! `// DWG G 10 -IP (Flowing water activates device in one direction only.) Installation Requirements A CAUTION Model Nominal Pipe Size Nominal Pipe 0 0 Hole Size Il -Bolt Nuts Torque Waterflow switches that are monitoring wet pipe inch rim inch mm inch mni ft - lb n - sprinkler systems should not be used as the sole VSR - 2 DN50 2 375 60 3 initiating device to ° discharge AFFF, delug e, or chemical suppression systems Waterflow switches VSR - 2 1/2 2 1/2 2 875 73.0 125 + 125/ 062 33 0± 2 0 used for this application may result in unintended VSR - V2 2 1/2 DN65 3 000 76 I discharges caused by surges, trapped air, or short retard times. VSR -3 3 DN80 3 500 88 9 VSR -3 Ill 3 1/2 4.000 101 6 20 27 VSR -4 4 DNI00 4500 114.3 200± 125 508±2.0 VSR -5 5 5 563 141 3 VSR -6 6 DN150 6.625 168.3 VSR -8 8 DN200 8 625 219 1 Fig. 3 Typical Electrical Connections Fig. 4 Fig. 5 �� NEGATIVE Break out thin section of cover when wiring both To remove knockouts: Place screwdriver at o 1 ±; BELL NEUTRAL switches from one conduit entrance. inside edge of knockouts, not in the center. 1 I AC }., , POSITIVE D(: 1' — - OR 110T AC lf' �i —1i■, 1.X/ / 1 IR Ir ,� •� III ON FIRE ZONE 1 mR ON FIRE E PANEL P4NF.L I � =+ �� Iii -4‘ 7. 01,._,:.07,1■1%,..; I Notes: yli j ''' ; I. The Model VSR has two switches, one can be used . ? to operate a central station, proprietary or remote <f ■AI, signaling unit, while the other contact is used to �`�'� operate a local audible or visual annunciator. p ` �� , � ' mo I (I� 2. A condition of LPC Approval of this product i '1 J ��Y is that the electrical entry must be sealed to �' r� exclude moisture. �� �� 3. For supervised circuits see "Switch Terminal Connections" drawing and caution note (Fig. 2). PRINTED IN USA MFG #5401146 - REV ii PAGE 2 OF 3 12/07 if' , VS I VANE TYPE WATERFLOW '', T ,a_i -`® The Symbol of Protection ALARM SWITCH WITH RETARD Compatible Pipe Note: For copper or plastic pipe use Model VSR -CF. Model Nominal Pipe Nominal Pipe Pipe Wall Thickness Size O D - Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch mm inch mm inch inm inch nun inch min VSR -2 2 DN50 2 375 60 3 0 109 2 77 0 154 3 91 0 142 3 6 0 091 2 3 VSR -2 1/2 2 lit 2 875 73 0 0 120 3 05 0 203 5 16 VSR -2 1/2 DN65 3 000 76 1 0 142 3 6 0 102 2 6 VSR -3 3 DN80 3 500 88 9 0 120 3 05 0.216 5 49 0 157 4 0 0 114 2.9 VSR -31/2 31/2 4000 1016 0120 3.05 0226 574 VSR -4 4 DN 100 4 500 114.3 0 120 3 05 0 237 6 02 0 177 4 5 0 126 3 2 VSR -5 5 5 563 141 3 0 134 3 40 0.258 6 55 VSR -6 6 DN 150 6.625 168 3 0 134 3 40 0,280 7 11 0 197 5 0 0 157 4 0 VSR -8 8 DN200 8 625 219.1 0 148 3 76 0 322 8 18 0 248 6 3 0 177 4 5 Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and /or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Maintenance Inspect detectors monthly for leaks. If leaks are found, replace the detector The VSR waterflow switch should provide years of trouble -free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029055. There is no maintenance required, only periodic testing and inspection Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U- bolts. . • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. Important Notice Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions Mounting Dimensions 890 mm (3 50 - ) GROUND SCREWS I_ _I 1��IIII 141,2 mm ®' it H � 59,4 mm � ■I��' (5 5G') (2 74 ") 50,8 mm 1, :1 :I . II — - - (2 00 ") • IM, •IIIMIMI■ K. Il °�_� I:: Ir, 3.-1301,1' NUT ii-I L Will i -HOLY WASHER PIPE ULA .O, I I.O, •• -` �� PIP +133.4 mm ���� `��tt!i —' —.ail Al II D SA DDLL . , . MI' -® 11 PIPE II / Nil PLASDC PADDLE Il U -BOLT NOMINAL PIPE DIA 644,5 1nm (6 I -3/4) FOR DN50 - DN65 (2 - 2 -1 ) NOMINAL PIPE DIA +54,0 mm (+ 2 -1 /0') FOR D\80 - DN200 (3 - 8 ") 0 W 64 1146 -0 PRINTED IN USA MFG 115401146 - REV H PAGE 3 OF 3 12/07 �o BELLS The Symbol of Protection PBA -AC & MBA -DC UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 4' 24VDC (20.4 to 31 2) Polarized Service Use Fire Alarm " " General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150 °F ( -40° to 66 °C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires 0 M �, DC Bells - Terminal strip ® Finish: Red powder coating Optional: Model BBK -1 weatherproof backbox Model BBX -1 deep weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general Notes: signaling devices. They have low power consumption and high decibel 1. Minimum dB ratings are calculated from integrated sound pressure ratings. The unit mounts on a standard 4" (101mm) square electrical box measurements made at Underwriters Laboratories as specified in UL for indoor use or on a model BBK -1 weatherproof backbox or BBX -1 Standard 464. UL temperature range is -30° to 150 °F ( -34° to 66 °C). deep weatherproof backbox for outdoor applications. Weatherproof 2. Typical dB ratings are calculated from measurements made with a backbox model BBK -1. Stock No. 1500001. conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies tp MBA DC bells. Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft. (3m) (2) 10 ft. (3m) (I) 6(150) 12VDC MBAl26 1750070 .12A 85 76 8 (200) 12VDC MBAI28 1750080 .12A 90 77 10(250) 12VDC MBAl210 1750060 .12A 92 78 6 ( 150) 24VDC MBA246 1750100 .06A 87 77 8 (200) 24VDC MBA248 1750110 .06A 91 79 10 (250) 24VDC MBA2410 1750090 .06A 94 80 6 (150) 24VAC PBA246 1806024* .17A 91 78 8 (200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6 (150) 120VAC PBAl206 1806120* .05A 92 83 8 (200) 120VAC PBAl208 1808120* .05A 99 84 10 (250) 120VAC PBA 12010 1810120* .05A 99 86 All DC bells are polarized and have built -in transient piotectron * Does not have ULC listing 4 VVARN I N G In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK -1 or BBX -1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146 -4161 • Phone: 800 - 325- 3936 /Canada 888 - 882 -1833 • www.pottersignal.com PRINTED IN USA MKT #8850001 - REV X PAGE I OF 2 MFG #5400776 - 2/08 3B Nth. POTTER BELLS The Symbol of Protection PBA -AC & MBA -DC h e :r .':'. (b :.:. ,0a:k',S 6 T t'. W a;r- k.....� , , sa.V?:si^!{N.N:FII6'lAw'1. .Rl� dE- :f.'JYCW:SftLL'!!RR3F"' - 1KA t`YYJi� xE.K?ilB:. °PN.iF+). WSSnQ'PI jMBX1iW*,i PFlu6 = Xit17JAL. Bells Dimensions Inches (mm) Wiring (rear view) Fig. I Fig. 3 A.C. BELLS i, WurE( hrrE(olr> (50) — 1 ^ — 8" i 1000411 � FROM CONTROL (200) 6^ I PANEL OR (150) �� PRECEDING BELL / I 1 — `� r — J BLACK i1N1 _ BLACK (OI.T) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS 45 SHOWN 21U16" (68) DWCP 776 -I N(Il h5 I WHEN USLNG AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL 2 END -OF -LINE RESISTOR IS NOT REQUIRED ON AC BELLS fAl OA 7,3 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 FACP Box has one threaded 1/2" conduit entrance 1 'i — 1 — . U �' I 53/4" O _ 3 3 / 8 " 5 J . T o Next (146) (86) (127) 1 Device or 1 1 End -of -Line • ' Resistor w L- 3 3/8" 15 /R' L.._ (86) (41) , 4 1/4" (INS) Installation DWGO 776-2 I. The bell shall be installed in accordance with NFPA 13, 72, or local AHJ The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 2. Remove the gong. 7 1 :411N 4 ■ . ,,. ) 4 0 0 ,- o 3. Connect ect wiring (see Fig. 3). / 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 001b 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). o `s`l 6. Co Test all bells for proper operation and observe that they can I3LiX -1 be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). ,.i- 3: i s / AWARNING . Failure to install striker down will prevent bell from operating. PRINTED IN USA MKT. #8850001 - REV X PAGE 2 OF 2 MFG. #5400776 - 2/08 ,. , tqc,..i,. Fire Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Preaction st with l Deluge l v Single Interlock, Supervised — Electric ct at 1-1/2 thru 8 Inc (DN40 thru 0N200) General i Description ((� ties' �C The Model DV -5 Supervised Single In- �� •Lf. terlock Preaction System with Electric - e�%'%'" Actuation (Fig. 1) utilizes automatic sprinklers and a supplemental detec- - tion system. The supplemental detec- tion system is typically comprised of 24 VDC heat detectors, smoke detec- tors, manual pull stations, etc. Actua- tion of the detection system automat -� ically operates (releases) the Model DV -5 Deluge Valve, allowing water to ∎ /( flow into the sprinkler piping system //'' and to be discharged from any sprin- 0111 . _ klers that may be open. !�_ ��C:?p. In accordance with the requirements =0� of the National Fire Protection Asso :, ,, != � 0 ciation, a preaction system employing il is ■«ramlii '° + -' — more than 20 automatic sprinklers is to �,� . — have the sprinkler piping automatically l °_ "� supervised to monitor the overall in- y _, P ` C = -��) tegrity of the system. In the case of a /J , ,`uii Supervised Single Interlock Preaction - ) {.� � �_ System, a Riser Check Valve (that 4,, ;,_,_ , my uire the use of priming q p 9 :: does not require --e .;n water) provides an air check so that� the system can be automatically pres- G!). surized with a nominal supervisory air -' " ""` ~�` Wilt or nitrogen pressure of 10 psi (0,69 `, t,, ' bar). A supervisory low pressure alarm switch that is set to transfer its contacts at nominally 5 psi (0,34 bar), on de- creasing pressure, is utilized to indi- cate whether there are any abnormal leaks in the sprinkler system piping. system will have begun to fill with extinguishment by alternate suppres- Loss of air pressure from the system water before a sprinkler operates. sion means, prior to a sprinkler dis as a result of a damaged sprinkler or Supervised single interlock preaction charge. In the event the fire cannot broken piping will not cause the DV -5 systems are generally used to protect otherwise be extinguished, the preac- Valve to open — the air pressure is for areas where there is danger of serious tion sprinkler system will then perform supervisory alarm only. water damage that might result from as the primary fire protection system. Typically, the system designer selects damaged automatic sprinklers or pip The Model DV - Deluge Valve (de- the detection components for a single ing. Typically, such areas include corn scribed in Technical Data Sheet interlock preaction system that will re- puter rooms, storage areas for valu- TFP1305) is a diaphragm style valve spond to a fire sooner than the auto- able artifacts, libraries, and archives. that depends upon water pressure in matic sprinklers. Consequently, the Single interlock preaction systems are the Diaphragm Chamber to hold the system will experience a minimal delay also effectively used to protect proper- Diaphragm closed against the water in water delivery over that for a wet ties where a pre -alarm of a possible supply pressure. When the DV -5 Valve pipe sprinkler system because the fire condition may allow time for fire is set for service, the Diaphragm (TEXT CONTINUED ON PAGE 9) Page 1 of 14 SEPTEMBER, 2004 TFP1420 • Page 2 of 14 TFP142O ' 0 0 if f at‘ IP _____ Ay ii 1 ili o /------ -).--• ‘,,. . kr • o I 1 • o ,.. ..___.,..,,c,i4..wo,._ ... ,:,.1,,,....2„,,„_.,•,,_ _,,;;,,,„•(.............(.. „. .. _____.. • i ,,,, .... _m - ____ .;:ilrioni.....ca ,_ _ , .,.gill m om" �I ' 40 ,,- ,7 Q iri1;/! 1 ) • —� 0 ta ri_ ,- Q f`,»( 116411H 0 . _ -: �- !WOW ;: N 4 1 - Model DV -5 Deluge Valve 9 - System Drain Valve (N.C.) 16 - Riser Check Valve 2 - Main Control Valve (N.O.) 10 - Main Drain Valve (N.C.) 17 - Supervisory Air Pressure Gauge 3 - Diaphragm Chamber Supply (Shown at Rear of Valve) 18 - Automatic Supervisory Air /Nitrogen Control Valve (N.O.) 11 - Diaphragm Chamber Automatic Supply 4 - Local Manual Control Station Shut -Off Valve 19 - Supervisory Low Pressure Alarm 5 Automatic Sprinklers 12 - Waterflow Pressure Alarm Switch Switch 6 - Heat Detectors, Smoke Detectors, (Shown at Rear of Valve) etc. (Fire Detection) 13 - Water Motor Alarm (Optional) 7 - Water Supply Pressure Gauge 14 Solenoid Valve 8 Diaphragm Chamber Pressure 15 - Deluge Valve Releasing Panel Gauge FIGURE 1 — PART 1 OF 2 SUPERVISED SINGLE INTERLOCK PREACTION SYSTEM WITH ELECTRIC ACTUATION — SYSTEM SCHEMATIC (Front View) — k. FFP1420 Page 3 of 14 4 0 f, isi d t, ..,„. „ si ( si- 7;; .' I 0 0 0 o • Or t ._,A., ,, ,) o l ____, II ..._. gl(....IIIIIIMINIMI(gIAICillFiNNIOlijlli • .l i j)91;7.-- .;_:T(IC.r 11 iii (trhi ar 1 . � Ir1 �in../ `:' ;111 �>]� e ilaritil,lr —_____---1 s. I luCki :.%4 • Mil 'MIT gig 1 - Model DV -5 Deluge Valve 8 - Diaphragm Chamber Pressure 16 - Riser Check Valve 2 - Main Control Valve (N.O.) Gauge (Shown at Front of Valve) 17 - Supervisory Air Pressure Gauge 3 Diaphragm Chamber Supply 9 - System Drain Valve (N.C.) (Shown at Front of Valve) Control Valve (N.O.) 10 - Main Drain Valve (N.C.) 18 - Automatic Supervisory Air /Nitrogen 4 - Local Manual Control Station 11 - Diaphragm Chamber Automatic Supply (Shown at Front of Valve) Shut -Off Valve 19 - Supervisory Low Pressure Alarm 5 - Automatic Sprinklers 12 - Waterflow Pressure Alarm Switch Switch 6 - Heat Detectors, Smoke Detectors, 13 - Water Motor Alarm (Optional) etc. (Fire Detection) 14 - Solenoid Valve 7 - Water Supply Pressure Gauge 15 - Deluge Valve Releasing Panel (Shown at Front of Valve) FIGURE 1 — PART 2 OF 2 SUPERVISED SINGLE INTERLOCK PREACTION SYSTEM WITH ELECTRIC ACTUATION — SYSTEM SCHEMATIC (Rear View) — Page 4 of 14 TFP142O ' NO DESCRIPTION QTY P/N NO DESCRIPTION QTY. P/N NO DESCRIPTION QTY. P/N 1 300 psi/ 2000 kPa 19 1/4" Plug .. .. .. 1 CH P1 250 psi/ 1750 kPa Water Pressure Gauge 2 92- 343 -1 -005 20 3/4" Plug . . ... 1 CH Air Pressure Gauge . . 1 92-343-1-012 2 1/4" Gauge Test Valve . 1 46- 005 -1 -002 21 1/2" Union .... . . 5 CH P2 1/4" Gauge Test Valve .. 1 46- 005 -1 -002 3 Model MC -1 Manual 22 3/4" Union .... 1 CH P3 Low Air Pressure Alarm Control Station . .. . 1 52- 289 -2 -001 23 1/4" 90° Elbow . .. . 1 CH Switch (PS10 -2A) . . 1 2571 4 Model AD -1 Automatic 24 1/2" 90° Elbow . . 7 CH P4 1/4" Pressure Relief Drain Valve 1 52- 793 -2 -004 25 3/4" 90° Elbow . . . 1 CH Valve .. . . . 1 92 -343 -1 -019 5 Automatic Shut -Off Valve, 26 3/4" x 1/2" 90° Elbow. . 1 CH P5 1/2" Swing Check Valve 1 46 -049 -1.004 Model ASV -1 .. . .. 1 92- 343 -1 -021 27 1/2" Tee . . . . .. 3 CH P6 1/2" Globe Valve .. . . 1 46- 047 -1 -004 6 Waterflow Pressure 28 1/2" x 1/4" x 1/2" Tee ... 3 CH P7 3/4" Angle Valve .. ... 1 46-048-1-007 Alarm Switch (PS10 -2A) .1 2571 29 3/4" Tee .. ... .... 1 CH P8 1/4" Plug .. .... . 3 CH 7 1/2" Ball Valve .... .. 2 46 -050 -1 -004 30 3/4" x 1/2" x 3/4" Tee . 2 CH P9 1/2" x 1/4" Reducing 8 1/2° Spring Loaded 31 1/4" x Close Nipple . 2 CH Bushing .... . . 1 CH Check Valve .. .. 1 92- 322 -1 -002 32 1/2" x Close Nipple . 3 CH P10 1/2" Union ... . ... 1 CH 9 1/2" Y- Strainer 1 52- 353 -1 -005 33 1/2" x 1 -1/2" Nipple . ..11 CH P11 1/2" 90° Elbow .. . 1 CH 10 3/4" Swing Check Valve .1 46-049-1-005 34 1/2" x 2" Nipple . . . . 1 CH P12 1/2" Cross .... .. .... 1 CH 11 3/4° Angle Valve .... 1 46- 048 -1 -005 35 1/2" x 2 -1/2° Nipple .... 3 CH P13 1/2" x 1/2" x 1/4" Tee .... 1 CH 12 Drip Funnel Connector . 1 92- 211 -1 -005 36 1/2" x 5" Nipple . 2 CH P14 1 "x 3/4" x 1/2" Tee .... 1 CH 13 Dnp Funnel Bracket .... 1 92- 211 -1 -003 37 1/2" x 7" Nipple 1 CH P15 1/4" x 3" Nipple .. . 1 CH 14 Drip Funnel 1 92-343-1-007 38 Select Nipple per Table 2 CH P16 1/2" x 1 -1/2" Nipple .. .. 5 CH 15 3/32" Vent Fitting .... 1 92-032-1-002 39 Select Nipple per Table . 2 CH P17 1/2" x 2 -1/2" Nipple . 1 CH 16 1/4" x 18" Tubing . . .. 1 CH 40 3/4" x 1 -1/2" Nipple . . 6 CH P18 3/4" x 1 -1/2" Nipple .. . 1 CH 17 1/2" Tubing Connector .. 1 CH 41 3/4" x 2" Nipple 1 CH P19 1" x 2" Nipple 1 CH 18 1/2" x 12" Tubing ... . 1 CH 42 3/4" x 4" Nipple .... .. 1 CH E1 Solenoid Valve Per Data Ordered Sheet TFP2180 1 Separately E2 1/2" Tubing Connector .. 1 CH P16 ;, PS P4 •-; E3 1/2" x 24° Tubing .. .. 1 CH ' E4 1/2" x 1 -1/2" Ni le 1 CH e, P11 P10 P3 c-, q v PP 44.4 1 P16 '` a�` P13 ' •••-, rI P1 14 ' 6 P16 sir e P9 ��u P 16 / P16 / P15 P6 Select Appropriate Nipple Sizes 15 P12 • �„ 26 Nulmber per DV -5 Delu a Valve Size -./ (GREEN 40 1 -1/2" (DN40) 2" (DN50) TINT) 16 P2 �;\ '' 1l 38 1/2" x Close 1/2" x 2" i P17 30 28 r , . � X1 1 11 P B e111 ; , 39 1/2" x 5" 1/2" x 5 -1/2" 1 - P18 ��r 27 •� ' u 11 311. ..4• P,'� all�l` P14 P19 12 IV �jr E1 20 4 E3 SEPARATED) 29 ` 22 P8 13 14 E 'ti E4 .S il LOCATION r 41 40 If '�' '° 21 FOR OPTIONAL / 0 i4 40 �� 36 21 32 33 ELECTRICALLY ; A O 40 'i PB ��—�j 7 °[ ''� °0 on, � "ree SUPERVISED 33 ep�l 10 �e � 00 27 N.O. ALARM , 24 :�0 40 40 �� 35 24 39 CONTROL VALVE 30 �� , e ` 24 0/ 24 i � ^ 1 (BVS -3/4 ") �l � , ire ¢_t,� RISER ,� ' 27 ' r� o 38 a\ '' "_ 25 �r, CHECK 3g 32 / (� iiik 11 42 I OA VALVE E , 4 33 28 7 /I ^ • (NOTE 2) ?11 35 1 "1)` 8 l 33 3 1� - NOTES: 21 � '����� 1 Supervised Single 19 2 4 33 r, c; 5 21 ;' ^A' ° - �, Interlock Preaction Trim m :!F n, 0' 36 24 �1 r r :, 1!ir 32 with Electric Actuation is comprised of Items 1 -42 33 2" (DN50) 9 i" v 34 18 / plus Items P1 -P19 and 31 q, ° " 28 GROOVE x GROOVE 0 33 33 ,` 24 17 24 Items E1 -E4. 31 MODEL DV -5 2 Use only the 2" Model CV -1 FR 23 DELUGE VALVE 21 Riser Check Valve for 1 -1/2" or SHOWN i NOTES: 2" assemblies .. 33 5. See Figure 2 of TFP1305 for 3. All Fittings and Nipples are 7 i Deluge Valve Port identification. galvanized (Standard Order). 6 Route all Tubing to Drip Funnel, 4. CH: Common Hardware. I Item 14. FIGURE 2A — PART 1 OF 3 1 -1/2 and 2 INCH (DN40 and DN50) MODEL DV -5 DELUGE VALVES SUPERVISED SINGLE INTERLOCK PREACTION WITH ELECTRIC ACTUATION TRIM (52- 478 -X -119) — EXPLODED VIEW — TFP1420 Page 5 of 14 NO DESCRIPTION QTY. P/N NO DESCRIPTION QTY P/N NO. DESCRIPTION QTY. P/N 1 300 psi/ 2000 kPa 18 1/2" x 18" Tubing , . 1 CH 38 1/2" x 5" Nipple . 1 CH Water Pressure Gauge .. 2 92- 343 -1 -005 1 9 1/4" Plug . . ... 1 CH 39 1/2" x 5 -1/2" Nipple .. 1 CH 2 1/4" Gauge Test Valve . . 1 46-005-1-002 20 3/4" Plug .. .... . 1 CH 40 1/2" x 7" Nipple .. ..... 2 CH 3 Model MC -1 Manual 21 1/2" Union . . .... 5 CH 41 3/4" x 1 -1/2" Nipple .... 5 CH Control Station 1 52-289-2-001 22 3/4" Union ..... .. 1 CH 42 3/4" x 2" Nipple ... . 1 CH 4 Model AD -1 Automatic 23 1/4" 90° Elbow .. .. . 1 CH 43 1 -1/4" x 2" Nipple .. . . 1 CH Drain Valve 1 52- 793 -2 -004 24 1/2" 90° Elbow . .. ... 7 CH 44 1 -1/4" x 4" Nipple ... ... 1 CH 5 Automatic Shut -Off Valve, 25 3/4" x 1/2" 90° Elbow . 1 CH Model ASV -1 .... ... 1 92- 343 -1 -021 26 1 -1/4" 90° Elbow . ... 1 CH P1 250 psi/ 1750 kPa 6 Waterflow Pressure 27 1/2" Tee .... .... . . 3 CH Air Pressure Gauge .... 1 92- 343 -1 -012 Alarm Switch (PS10 -2A) .1 2571 28 1/2" x 1/4" x 1/2" Tee . 3 CH P2 1/4" Gauge Test Valve .. 1 46- 005 -1 -002 7 1/2" Ball Valve ..... . . 2 46- 050 -1-004 29 3/4" Tee .... 1 CH P3 Low Air Pressure Alarm 8 1/2" Spring Loaded 30 3/4° x 1/2" x 3/4" Tee .. 2 CH Switch (PS10 -2A) 1 2571 Check Valve .. . . .. 1 92- 322 -1 -002 31 1/4" x Close Nipple .... 2 CH P4 1/4" Pressure Relief 9 1/2" Y- Strainer .. . 1 52- 353 -1 -005 32 1/2" x Close Nipple . .. 2 CH Valve .. .. ... . 1 92- 343 -1 -019 10 3/4" Swing Check Valve .1 46-049-1-005 33 1/2" x 1 -1/2" Nipple ....13 CH P5 1/2" Swing Check Valve .1 46- 049 -1 -004 11 1 -1/4" Angle Valve 1 46- 048 -1 -007 34 1/2" x 2 -1/2" Nipple 1 CH P6 1/2" Globe Valve .. .. 1 46- 047 -1 12 Drip Funnel Connector 1 92- 211 -1 -005 35 1/2" x 3 -1/2" Nipple 1 CH P7 1 -1/4" Angle Valve .. .. 1 46 -048 -1 -007 13 Drip Funnel Bracket .... 1 92- 211 -1 -003 36 1/2" x 4" Nipple 1 CH P8 1/4" Plug.. .. ... .... 3 CH 14 Drip Funnel . 1 92- 343 -1 -007 37 1/2° x 4 -1/2° Nipple .... 1 CH P9 1/2" x 1/4" Reducing 15 3/32" Vent Fitting 1 92- 032 -1 -002 Bushing ... 1 CH 16 1/4° x 18" Tubing . .. 1 CH , = P10 1/2" Union . 1 CH 17 1/2° Tubing Connector • 1 CH P18 „� P4 - P11 1/2" 90° Elbow .... ... 1 CH P12 1/2" Cross 1 CH '\ c? P P16 X 1 1 P13 P 1/2" x 1/2" x 1/4" Tee .... 1 CH P18 P14 1 -1/4" x 1 -1/4" x 1/2" Tee 1 CH »��' '21 P5 P1 25 P15 1/4" x 3° Nipple 1 CH P11 IBC P10 ' 41 P16 1/2" x 1 -1/2" Nipple 6 CH i 1/ P9 1> P17 1 -1/4" x 2" Nippl 1 CH ;.'° , � � ��. 33 P18 1 -1/4" x 3" Nipp 1 CH 6 P16 , vi„ _ P9 P16 l�' P15 P2 cL -'7� El Solenoid Valve Per Data Ordered Sheet TFP2180 1 Separate) 15 P12 ' / r \ 4 y �/ (GREEN '_ 27 F2 1/2" Tubing Connector .. 1 CH t. E3 1/2° x 24" Tubing .... .. 1 CH TINT) / 16 P 16 / P8 12 14 E4 1/2" x 1 -1/2" Nipple .... 1 CH 28 ,, p7 .....- , ",.. P17 0 lfrP /� 171` 30 a�1 \�� 20 . i P18 PLUG � � 13 [� El 711 P14 UNUSED No, (ORDERED n- lP\ w SEPARATELY) e li 34 41� -u 29 PORTS RISER E E4 P8 CHECK VALVE E2 • 0. LOCATION 42 41 1� 22 -� (NOTE 2) 39 21 33 *i •• •, 21 33 FOR OPTIONAL / eD��∎ �X / /�iie 41 `� 36 � i� .. P8 • %� �. , j a� a nla° r,l ELECTRICALLY 1 -* 41 :•: i t 27 SUPERVISED 33 O ,, 10 r ,. 6JO 0 I o' 24 40 N.O. ALARM 24 O VA 41 N n \ J � 24 ,/ 24 !X l' 1 CONTROL VALVE 0 � C �! ' li p 32 v �1 ' 93 30 (BVS -3/4 ") 7 111 �Q � � 33 32 / .. t �I 26 W I� ii , �i s / 33 � 28 • 'I 7 -4 - 43 44 g;1 11 40 - `l\ Ali �� 11 p :`ii � 33 3 Illi (flit 1 fl / 33 , :. ' S .. 21 1. NOTES: 1. Supervised Single 19 2 21 a ' 8 Interlock Preaction Trim /<° � , " 24 ; 9 33 ' 35 18 °viri 1:41 32 with Electnc Actuation `R 0 37 3 3 � q is comprised of Items 1-44 = 'mil 33 3" (DN80) � " 24 17 24 plus Items P1 -P18 and "" r 28 GROOVE x GROOVE 21 Items E1 -E4. MODEL DV -5 2 Use only the Model CV -1 FR 23 31 DELUGE VALVE NOTES: Riser Check Valve. SHOWN � 33 5. See Figure 2 of TFP1305 for 3. All Fittings and Nipples are 7 ► Deluge Valve Port identification. galvanized (Standard Order). 6. Route all Tubing to Drip Funnel, 4. CH Common Hardware. I Item 14. FIGURE 2A— PART 2OF3 3 INCH (DN80) MODEL DV -5 DELUGE VALVES SUPERVISED SINGLE INTERLOCK PREACTION WITH ELECTRIC ACTUATION TRIM (52- 478 -X -116) — EXPLODED VIEW — Page 6 of 14 TFP142O ' NO. DESCRIPTION QTY P/N NO. DESCRIPTION QTY. P/N NO. DESCRIPTION QTY. P/N 1 300 psi/ 2000 kPa 22 1/2" Union . 5 CH 47 1" x 3" Nipple .. . .. . 1 CH Water Pressure Gauge .. 2 92 -343 -1 -005 23 1" Union .. .... . 1 CH 48 Not Used ... ..... .. 0 N/A 2 1/4" Gauge Test Valve . 1 46- 005 -1 -002 24 1/4° 90° Elbow . . .. 1 CH 49 2" x 3" Nipple . .... . 2 CH 3 Model MC -1 Manual 25 1/2" 90° Elbow .. . .... 7 CH Control Station .. .. ... 1 52- 289 -2 -001 26 1/2" Tee ... .. . . . 3 CH P1 250 psi/ 1750 kPa 4 Model AD -1 Automatic 27 1/2" x 1/4" x 1/2" Tee . 3 CH Air Pressure Gauge . 1 92- 343 -1 -012 Drain Valve . .. .... 1 52- 793 -2 -004 28 3/4" x 1/2" x 3/4" Tee .. 2 CH P2 1/4" Gauge Test Valve .. 1 46- 005 -1 -002 5 Automatic Shut -Off Valve, 29 1" x 1/2" 90° Elbow ... 1 CH P3 Low Air Pressure Alarm Model ASV -1 .. . .. 1 92- 343 -1 -021 30 1" x 3/4° x 1" Tee .. ... 1 CH Switch (PS10 -2A) 1 2571 6 Waterflow Pressure 31 2" 90° Elbow . . .. 1 CH P4 1/4" Pressure Relief Alarm Switch (PS10 -2A) .1 2571 32 1/4" x Close Nipple ... 2 CH Valve . .. ... . .... 1 92- 343 -1 -019 7 1/2" Ball Valve ... 2 46-050-1-004 33 1/2" x Close Nipple . 2 CH P5 1/2" Swing Check Valve 1 46- 049 -1 -004 8 1/2" Spring Loaded 34 1/2" x 1 -1/2" Nipple 10 CH P6 1/2" Globe Valve . .. 1 46-047-1-004 Check Valve . .. ..... 1 92- 322 -1 -002 35 1/2" x 2 -1/2" Nipple .. .. 2 CH P7 2" Angle Valve 1 46 -048 -1 -009 9 1/2" Y- Strainer . ... 1 52-353-1-005 36 1/2" x 3" Nipple .. .. .. 1 CH P8 1/4" Plug . .. .... 3 CH 10 3/4" Swing Check Valve 1 46-049-1-005 37 1/2° x 5" Nipple . 2 CH P9 1/2" x 1 /4" Reducing 11 Not Used .. . . . .. 0 N/A 38 1/2" x 6" Nipple 1 CH Bushing ..... .... . 1 CH 12 2° Angle Valve .... ... 1 46 -048 -1 -009 39 1/2" x 7" Nipple 2 CH P10 1/2" Union 1 CH 13 Dnp Funnel Connector . 1 92- 211 -1 -005 40 Select Nipple per Table . 2 CH P11 1/2" 90° Elbow ... .. 1 CH 14 Drip Funnel Bracket .. 1 92- 211 -1 -003 41 Select Nipple per Table .. 2 CH P12 1/2" Cross . . 1 CH 15 Drip Funnel 1 92- 343 -1 -007 42 Select Nipple per Table . 2 CH P13 1/2" x 1/2" x 1/4" Tee . .. 1 CH 16 3/32" Vent Fitting ... .. 1 92- 032 -1 -002 43 3/4" x 1 -1/2" Nipple . .. 1 CH P14 2" x 2" x 1/2" Tee .. . . 1 CH 17 1/4" x 24" Tubing 1 CH 44 3/4" x 2" Nipple . . . 1 CH P15 1/4" x 3" Nipple . 1 CH 18 1/2" Tubing Connector . 1 CH 45 Select Nipple per Table 2 CH P16 1/2" x 1 -1/2" Nipple . . 6 CH 19 1/2" x 24" Tubing . . . . 1 CH 46 1" x Close Nipple 2 CH P17 2" x 3" Nipple . .. .... 2 CH 20 1/4" Plug.. . .... .. 1 CH 21 3/4" Plug... . . . .. 1 CH El Solenoid Valve Per Data Ordered P16 0 � ° P4 Sheet TFP2180 ..... 1 Separately P16 E2 1/2" Tubing Connector .. 1 CH ', P13 E3 1/2" x 24° Tubing . . .. 1 CH P16 L ,+ \' P6 ci3 E4 1/2" x 1 -1/2" Nipple . 1 CH t). ;;:l P P1 P11 t P10 P3 46 29 Select Appropnate Nipple Sizes o � Nipple per DV -5 Deluge Valve Size " 6 P16 • vi P9 �� .. 36 No. 4" 6" 8" / � a P16 / P ' (DN100) (DN150) (DN200) \' 16 P12 �'.y P2 U A0- 40 1/2° x 2 -1/2° 1/2" x 5 -1/2" 1/2" x 8 -1/2" (GREEN 17 ' � 26 r 4 41 1/2" x 2" 1/2" x 3" 1/2" x 3 -1/2" P16 P = 42 1/2" x 6 -1/2° 1/2° x 7 -1/2° 1/2" x 9" 27 O.5 ' P14 � : �� PLUG 13 15 45 3/4" x 2 -1/2" 3/4" x 3-1/2" 3/4" x 4 -1/2" 28 r ul. 21 I P7 P17 \ 1 111 1\ 1 UNUSED \ El \ �� P1 PORTS \ \ 14 E3 i v (ORDERED :,� Jl� 35 ���11 ' _F - SEPARATELY) P8 RISER E 2 Iti 8 �, i 41, .� 30 �� CHECK VALVE Vii, 22 44 LOCATION d� : , )I " �p 38 22 41 ;; =;, . /'�I �/ ` C 23 P8 �� N (NOTE 2) E4 FOR OPTIONAL 1 34 4 .!" 1. ( �� �0 ` -- �*r ELECTRICALLY �!� , 43 46 q• ,� 14�� �u a���u :; a i.e h 26 SUPERVISED 34 o 010 10 1 �� ` 01 25 42 � N.O. ALARM �� 45 / R /. CONTROL VALVE 25 47 0 ►��4 25 1 35 " o �� , 1 r� 28 d i 25 1 26 e, a (BVS-3/4") �l 1 1\� ` ill! / ��� jj/ I i I, — 33 ), ,� 27 �� \1 , f' 34 Z. 34 - `� 7 �: 1 31 �° % 39 Li ,,• 1\ 49 49 y 9 :�=% 34 3 r 34 o O NOTES: 39 1 , �i i� - , "�0 22 ii 1. Supervised Single ( o \ ` � Interlock Preaction Trim d 20 .� 2 22 � � •l 34 I 37 19 • 'r I` 33 with Electric Actuation is comprised of Items 1 -49 R ,. lP Air 37 34 ! 25 At? Q 18 plus Items P1 -P17 and = !mil 34 .Z, /V 25 25 Items E1-E4. 4 " (DN100) 'y.e 22 32 °fir 27 FLANGE x GROOVE 2 Use only the Model CV -1 FR NOTES: Riser Check Valve. 24 32 MODEL DV -5 _ 34 DELUGE VALVE i i 5. See Figure 2 of TFP1305 for 3 All Fittings and Nipples are SHOWN Deluge Valve Port identification. galvanized (Standard Order). i 7 6. Route all Tubing to Drip Funnel, 4. CH: Common Hardware. I Item 15. FIGURE 2A — PART 3 OF 3 4, 6, and 8 INCH (DN100 and DN200) MODEL DV -5 DELUGE VALVES SUPERVISED SINGLE INTERLOCK PREACTION WITH ELECTRIC ACTUATION TRIM (52- 478 -X -113) — EXPLODED VIEW — L. . TFP1420 Page 7 of 14 NOTES: Nipple Select Appropriate Nipple Sizes per DV -5 Deluge Valve Size 1 Use only the 2" Model CV -1 FR Riser Check Number 1 -1/2" (DN40) 2" (DN50) 3" (DN80) 4" (DN100) 6" (DN1 50) 8" (DN200) Valve with 1 -1/2" and 2" DV -5 Valves Use 1 1/2" x Close 1/2" x 2° 1/2" x 1 -1/2" 1/2" x 2 -1/2" 1/2" x 5 -1/2° 1/2" x 8 -1/2" corresponding sized Model CV -1 FR Riser Check Valves for 3 " -8" Model DV -5 Valves 2 1/2" x Close 1/2" x Close 1/2" x 1 -1/2" 1/2" x 2" 1/2" x 3" 1/2" x 3 -1/2" 2 Nipples 1 -4 vary in length relative to the 3 1/2" x 5" 1/2" x 5 -1/2" 1/2" x 7" 1/2" x 6 -1/2" 1/2" x 7 -1/2" 1/2" x 9" Model DV -5 size used Select per the 4 3/4" x 1 -1/2" 3/4" x 1 -1/2" 3/4" x 1 -1/2" 3/4" x 2 -1/2" 3/4" x 3 -1/2" 3/4" x 4 -1/2" table. All other nipples packed unassembled System shall be installed per the appropriate trim Main Drain 3/4" NPT 3/4" NPT 1-1/4" NPT 2" NPT 2" NPT 2" NPT exploded view, Figure 2A Part 1, 2, or 3 Size 3 Install subassemblies in alphabetical order. Main Drain 4 See Figure 2 of TFP1305 for Deluge Valve Size 3/4" NPT 3/4" NPT 1 -1/4" NPT 2" NPT 2" NPT 2" NPT Port identification. 5. Route all Tubing to Drip Funnel VENT FITTING SYSTEM LOW AIR (GREEN TINT) AIR SUPPLY PRESSURE WATERFLOW CONTROL VALVE ALARM SWITCH PRESSURE a' (NORMALLY ' \ / OPEN) 1 � 1/2 INCH NPT ALARM SWITCH r CONNECTION 3/4 INCH NPTii� DRIP • FOR SYSTEM AUTOMATIC FUNNEL AIR SUPPLY CONNECTION FOR 1 -o.--' DRAIN WITH 1 -1/4 ` `1�� SOLENOID VALVE, WATER MOTOR 'l* B VALVE INCH NPT r,,i ORDERED SEPARATELY 1/2 INCH ALARM e'� ' CONNECTION �P'�' SYSTEM (NORMALLY CLOSED) CONDUIT ���`ll� TO DRAIN �� AIR SUPPLY CONNECTION ii �'`?)�1(i�: - '9 `�, PRESSURE NIPPLE 1 FOR "ELECTRIC �!, �r / GAUGE DETECTION" 4 �D �f((C PLUG F .: '1 UNUSED ,y -. ; 41.0 SYSTEM PORTS RISER �' CONNECTION R i u) CHECK VALVE NIPPLE i C � �� (NOTE 1) 2 (SIZED PER i `,1 -l(g moo∎« nrn` cl NIPPLE TABLE) J v \ m I v 1 SYSTEM MAIN h ��,� , NIPPLE DRAIN VALVE % �� ' pils•J i AUTOMATIC ' 4 3 (NORMALLY i . SHUT -OFF VALVE �`% •�� / MAIN (NORMALLY ( .. DIAPHRAGM l' CLOSED) tf� '� DRAIN VALVE •:Vo � ,' (,.1-; CHAMBER (NORMALLY E Irl � `�(1.0 ( �1 a OPEN) m i ~ PRESSURE / GAUGE \,1. p ALARM 4. TEST VALVE •i A ° k , l , �� � a (NORMALLY ■%. ��r _ Ill"1� 0 'li MANUAL CLOSED) •'`� F ! D • " CONTROL �� 4- STATION it . -., SYSTEM � • WATER _ ' 4" (DN100) DIAPHRAGM C " CHAMBER SUPPLY SUPPLY �� FLANGE x GROOVE PRESSURE :icr: I MODEL DV -5 CONTROL VALVE GAUGE _ MAIN DRAIN DELUGE VALVE (NORMALLY CONNECTION SHOWN 1/2 INCH NPT OPEN) (SIZED PER TABLE) CONNECTION FROM WATER SUPPLY FIGURE 2B 1 -1/2 thru 8 INCH (DN40 thru DN200) MODEL DV -5 DELUGE VALVES SUPERVISED SINGLE INTERLOCK PREACTION WITH ELECTRIC ACTUATION TRIM — OPERATIONAL COMPONENTS — Page 8 of 14 TFP142O ' Valve Nominal Installation Dimensions in Inches and (mm) Size A B C D E F G H J K L M 1 -1/2" 7 00 8.88 13.00 10.50 20.50 4 00 5 81 5 81 3.00 7.00 4.00 14.81 (DN40) (177,8) (225,4) (330,2) (266,7) (520,7) (101,6) (147,6) (147,6) (76,2) (177,8) (101,6) (376,2) 2" 7.13 9.13 13.00 10 50 21.06 3.13 6.00 6.00 3.00 7.00 3 13 15.38 (DN50) (181,0) (231,8) (330,2) (266,7) (535,0) (79,4) (152,4) (152,4) (76,2) (177,8) (79,4) (390,5) 3" 7.81 10.44 14.50 10.50 25.00 1.69 6.69 6.69 4.25 7.00 0.25 21.13 (DN80) (198,4) (265,1) (368,3) (266,7) _ (635,0) (42,9) (170,0) (170,0) (108,0) (177,8) (6,4) (536,6) 4" 10.00 11.75 17.88 10.50 29.13 175 6.50 8.56 6.25 7.13 0.38 25.38 . (DN100) (254,0) (298,5) (454,0) (266,7) (739,8) (44,5) (165,1) (217,5) (158,8) (181,0) (9,5) (644,5) 6" 11.38 14.31 18.75 10.50 31.94 3.50 7.88 9.94 6.25 7.13 1.56 29.63 (DN150) (289,0) (363,5) (476,3) (266,7) (811,2)_ (88,9) (200,0) (252,4) (158,8) (181,0) (39,7) (752,5) 8" 12.00 16.00 21.25 10.50 36.75 1.75 10.75 10.63 6.25 7.13 7.13 36.50 (DN200) (304,8) `406,4) (539,8) (266,7) (933,5) (44,5) (273,1) (269,9) (158,8) (181,0) (181,0) (927,1) * MINIMUM CLEARANCE A I B C * I D* f r ti..: 1 :1- '7 %1� i1r a�t' , =1� {,. A ' ; •' 1_..011101.1, Flialit -.17.1.__,4•.1 E 1/2" NPS a :; \ lumenaki V Q I I � ,=' ,I '�I�I�' I M I � DIAPHRAGM �•• O O ii rli� CONNECTING TRIM i • CHAMBER SUPPLY � '! I I I "'IF ^ `� U F ,i D Q,� - (FIELD FABRICATED) ;; I I i iI� 41 L + n _ , _ 1 I _ n 1 T` � 4,C I l I -�.a- r--- VI \ '' I J L '{- 17. Ih �! 4� I F 1 1 I 1 i " 1 r -___ U - - - -� 1 lJ, 1 : :�\ III 1 1 ( - -. =1,- i. I1 A -.-1 -i ✓L U 1 ___ I I lal MAIN 16-j 1.-.1 G CONTROL 2" NPS 1 -1/4" NPS VALVE DRAIN DRAIN H J K LEFT VIEW FRONT VIEW FIGURE 3 1 -1/2 thru 8 INCH (DN40 and DN200) MODEL DV -5 DELUGE VALVES SUPERVISED SINGLE INTERLOCK PREACTION WITH ELECTRIC ACTUATION TRIM — NOMINAL INSTALLATION DIMENSIONS — ITN 420 Page 9 of 14 Chamber is pressurized through the system to be hydraulically calculated trim connections from the inlet side of Technical as a wet pipe system, as opposed to a the system's main control valve, such dry pipe sprinkler system, the detec- as an O.S. &Y. gate valve or butterfly tion system must be designed to oper- valve (Fig. 1). ate sooner than the automatic sprin- Approvals klers on the sprinkler piping. Operation of an electrical detection de- UL and C -UL Listed. FM Approved. vice such as a heat sensitive thermo- The Supervised Single Interlock Pre - stat, smoke detector, or electrical man- Deluge Valve action System With Electric Actuation ual control station signals the deluge Model DV -5. Trim provides for electric operation of valve releasing panel to energize the Riser Check Valve the DV -5 Valve by a detection system Solenoid Valve. In turn, the energized Model CV -1 FR. consisting of electrical devices such as Solenoid Valve opens to release water heat sensitive thermostats, smoke de- from the Diaphragm Chamber faster NOTE tectors, and /or electric manual pull sta- than it can be replenished through the 1 -1/2 inch (DN40) risers utilize a 2 inch tions. Information on the various types 1/8 inch (3,2 mm) restriction provided (DN50) Riser Check valve in combing of separately ordered Solenoid Valves by the Model ASV -1 Automatic Shut- tion with the 1 -1/2 inch (DN40) Model that may be used with this trim pack - Off Valve in the diaphragm supply con- DV -5 Deluge Valve. age is given in Technical Data Sheet nection (Item 5 - Fig. 2A, also de- TFP2180. Nominal installation dimen- scribed in Technical Data Sheet sions for the Supervised Single Inter - TFP1384). This results in a rapid pres- Valve Trim lock Preaction System With Electric sure drop in the Diaphragm Chamber The Supervised Single Interlock Pre- Actuation Trim are shown in Figure 3. to below the valve trip point. The water action System With Electric Actuation supply pressure then forces the Dia- Trim (Fig. 2A/2B) forms a part of the NOTES phragm open, permitting water to flow laboratory listings and approvals. The Approval by Factory Mutual is contin- into the system piping, as well as trim is necessary for proper operation gent on the use of an FM Approved through the Alarm Port to actuate the of the DV -5 Valve. 24VDC Solenoid Valve (P/N52- 287 -1- system alarms. Each package of trim includes the fol- 024 or P/N 52- 287 -1 -124). FM only As water flows into the system, the lowing items: approves solenoid valves for use in pilot chamber of the Model ASV -1 non hazardous locations. Automatic Shut -Off Valve (Item 5 - Fig. • Water Supply Pressure Gauge Consult with the Authority Having Ju- 2A) becomes pressurized and the • Diaphragm Chamber risdiction regarding installation criteria ASV -1 automatically shuts off the dia- Pressure Gauge pertaining to electric actuation cir- phragm chamber supply flow to the • Diaphragm Chamber Connections cuitry. DV -5 Diaphragm Chamber. Shutting • Manual Control Station The Supervised Single Interlock Pre - off the diaphragm chamber supply flow Main Drain Valve prevents the DV -5 Diaphragm Cham- action System With Electric Actuation Trim is provided with a Model ASV -1 ber from becoming re- pressurized, o System Drain Valve Automatic Shut -Off Valve (Item 5 - Fig. thereby preventing inadvertent closing . Alarm Test Valve 2A); consequently, the release circuit of the DV -5 during a fire (as may be the • Automatic Drain Valve of the releasing panel need only pro - case should the Solenoid Valve be- • System Air Pressure Gauge vide the standard ten minutes of alarm come de energized after its initial op- Y condition intended to energize the So- eration). • Air Supply Connections lenoid Valve. After the ten minute du- WARNING • Low Air Pressure Supervisory ration, should the Solenoid Valve be- The Model DV -5 Supervised Single In- Switch come de energized and close terlock Preaction System with Electric • Waterflow Pressure Alarm Switch (especially while operating under bat - Actuation Trim described herein must tery back-up), the Automatic Shut Off be installed and maintained in compli To ease field assembly of the trim ar- Valve will have already automatically ance with this document, as well as rangement, the trim components are closed thereby preventing the DV -5 with the applicable standards of the provided partially assembled as Diaphragm Chamber from becoming National Fire Protection Association, shown in Figure 2B re- pressurized and preventing an in- in addition to the standards of any The trim arrangement is provided with advertent closing of the DV 5 during a jurisdiction. fire event. other authorities having j galvanized or black nipples and fit - Failure to do so may impair the per- tings. The galvanized trim is intended System Air Pressure Requirements formance of the related devices. for non - corrosive or corrosive condi- The supervisory air (nitrogen) pres- The owner is responsible for maintain- tions, whereas the black trim is princi- sure is to be 10 plus or minus 2 psi ing their fire protection system and de pally intended for use with AFFF sys- (0,69 plus or minus 0,07 bar). The use vices in proper operating condition. tems of a higher supervisory pressure is The installing contractor or manufac subject to approval by the Authority turer should be contacted with any NOTE Having Jurisdiction, and it should be questions. When the system pressure is greater understood that the use of a higher than 175 psi (12,1 bar), provision is to supervisory pressure may increase be made to replace the standard order water delivery time. The use of a lower 300 psi (20,7 bar) Water Pressure supervisory pressure may prevent Gauges, shown in Figure 2A/28 with clearing the alarm of the Supervisory separately ordered 600 psi (41,4 bar) Low Pressure Alarm Switch (Item P3 - Water Pressure Gauges. Fig. 2A), which is factory set to alarm at 5 plus or minus 1 psi (0,34 plus or Detection System minus 0,07 bar) on decreasing pres In order for a single interlock preaction Page 10 of 14 TFP142O FLOW RATE IN LITRES PER MINUTE (LPM) (1 GPM = 3,785 LPM) 200 400 600 1000 2000 3000 5000 7000 10000 15 0 1111111110010111111111111111111/11111111111 1,00 0,900 0 n. 1 .. 1= - 0,800 10.0 ■ o ∎ =r .a.or m�..o .....n. r,u ...►;.��....orI .■ 0,700 9 i ui i i i ii ... moom 5' r i ... r. m ouMI iE SUM l u ri• uu, •ii1U■i••. u riiiiii 0,600 d 8 0 111111■■..■.II• G A ■ VENN■■ ■■... .II■'A111■■■.L.IMIN•■ ■ ■■.rAM. ■•■ � 1 1 11 ■t r1 •IU•■■■■ ■IIIIIIV 11■1■■ ri■III �■■■ ■III���■ ■— I 11111■ ■I ■■:■ ■I■ :i ' o� ,InimE■ ■■C■IIIIIIV4nIn ■ ■II ■III= ■■■■■■'4UIU•■■■ 0,500 z 7 0 11111=11111111111 •Z` r � I■1 ■ ■■ ■■■■■IIIID VIIIM ■IA■■IIII■ ■■■■■/,■■I•■■ ■r s o 'nut ■.■■■■I , o i■■■■■■■■■■■■■ ur71111111 •r1■■■■I■ ■■.■r1■■I■■■■f w 1 : : : :__ : = AWL': =_' - .- 'I= : : :::= = = ==rr : : :: =_= 0,400 - ---_ --- . ∎ ∎ - - -- _•. -- --- ■MME- -••----- ∎ ∎ - _ .- . co ............. �.....N� = =. 0 .... ■..•A.... MEMO ��� u 0,300 cc ..................n. 2 '4 u•.u........ w....... rur.. Q W 11 4.0 ....1.r. IMM'a....... =■■ Q 1 .r..1 ME ..1■ = =r/......■ ��M.. ' m 111 .. MI �r:�t•■..•.. •■ , ... IS' !I111U......IIEM'A.•..... rA ■■ ■■ z d 11111 ■■■■•.' /I M /I■■■■■ ■I■ ■■ `r ■I. FAME ^ 111111 ■..■..II�I,�■■ ■■••urA•■■■ 0 3.0 11111 ME i1MNIIMiii ■ ? MM I 9 r IIIIII......UI A•UUUUUP • iiii ' 0 Q 11111 ■ ■ ■■ eb I■■ ,Z 71111111■ ■■■ III ■ ■■ ■■ ■■'Al•■■■■ 0 , 200 cc m j IIIIII ■ ■rI� ■ ■ ■ri ■ ■ ■ ■ ■ ■r ■ ■�■ II ■■ r �O 'IIII111iiU•U p� I A •• o u ., o 11111■ ■pI■ ■GI■■■ ■■■ ■■ ■1■ ■I,a■ 1111111111■■ 4, i1 I w m a 11111 ■ ■■■■u111 ■■'A ■ '` 1111111■■ . FAI■■ ■P1111■ ■■■ ' o= co Z 2.0 11111PA ■■G111•MI■ ■■■III ■�I■•■ II1I1111 ' Mil 'A1111 ■E■■■ n o a ...1___. ■___...r/..■ .r 'A.. Os, r:..o.wonni.■ 11ur. AN■r A■ ...I�■■■■■..v.■■U■■r...Inm11111 0 L.. q, •a■■.O�■■■■ w II 111'1 ■... I.. ■■■..... A•■■.' A...III:11111 ' .I _ r,7..■.Iim■ ■. cc Ir'O■■r ■■■MIAIM ■■I/■.. , A N N A o , 'I a a 1111■ I:■■■ ■II. ■ ■ ■ ■■■■r7 ■L■■IIIIIIII111 r4■I■ w 11111I/ ■ ■IIII■•■■ ■ ■ ■■II■ ■ti /■ ■■ III111 11 AM p 'I `r ■■■■ ■II ■■■ ■ 0,100 4 c 11111. ■C■■II1 ■■IMEWI ■I ■MIWAM IIIIIIIIIIII■► M , EMEMI■ ■I ■■ ■ =r z D 1 11: ■■■■■■■ 1■■■■ ■Pi■■1 ■ ■Ii ■ ■ ■■■■1111111111Vi ■ ■■ w U■ ■ ■■■■■1■■■■■ 0 – n ■ 1' I 11111111!■ ■ ■■ I� ■ ■ ■ ■■ ■111•■■ 0,080 crw ,. �� III111111111111111111�11 11 111111I1�ii PJ UiIIIHHi ..:.LIii ■UURI 0 Z MU1.....■•u r U■... Ii■■■■■■.I .■no ruul■■.NMOANM■■■■■■...NN■■■ 0,060 a 11111■■.....IM /A ■■■..LI.. ■ ■■■. ■ I. 1Ir /11111■■■■ Mr, .IMI■■■ ■.■..IM■■■■ . 0. 8 11 ■I■■■■ ■IIIWI■■■■■UIMM ■■■■■I■I IM11111■■■■raII ■■■■■■■.I MEMIN g 0.7 11111■ ■■■■ III /. ∎ ■ ■■■ , d nomo■■■■■ IIIr duii1111 ■ ■■ ■'IIIIn ■ ■■■■■■II• ■ ■ ■■ 0,050 2 o.6 11111111111PA 1111211111111111111111111111 11111111111111111111111 _ : : := = := ==r.a= : : : : :____ : :: •-- _= _ : ; : :___= 0,040 .. .. ::_= :: ::: = =r : :: - - ---.• - _: : : : := __= : : : : : : = = =: 0.5 i..---7 �.----- - - -A i --- °° ∎�----- 0.M�--. ........ I ...■ NE►I.. • =MO=.. r..:. r �....... •••••1•111....... = = =.. •.I.... FAN ... ■W ∎..... ■.. 1• = =..'I .....r....... ■■ ���......■ M� =.. uu1.. ∎....1 I4�IM......1 �1M�.r..■ 1.%u.. .ZEZIO1 ■■..1.21.. 0,030 0.4 .■■u --•U U - = =.....• M =Mr a •,u.��.� � ..� ����.� 50 100 200 400 600 1000 2000 3000 FLOW RATE IN GALLONS PER MINUTE (GPM) The approximate friction loss, based on the Hazen and Williams formula and expressed in equivalent length of pipe with C =120, is as follows: 15 feet of 1 -1/2 Sch. 40 pipe for the 1 -1/2 inch Valve Combination ** calculated on a typical flow rate of 100 GPM. 28 feet of 2 inch Sch. 40 pipe for the 2 inch Valve Combination* calculated on a typical flow rate of 175 GPM. 37 feet of 3 inch Sch. 40 pipe for the 3 inch Valve Combination` calculated on a typical flow rate of 350 GPM. 48 feet of 4 inch Sch. 40 pipe for the 4 inch Valve Combination* calculated on a typical flow rate of 600 GPM. 73 feet of 6 inch Sch. 40 pipe for the 6 inch Valve Combination* calculated on a typical flow rate of 1500 GPM. 103 feet of 8 inch Sch. 40 pipe for the 8 inch Valve Combination* calculated on a typical flow rate of 2500 GPM. GRAPH A DELUGE AND CHECK VALVE COMBINATION* — NOMINAL PRESSURE LOSS VERSUS FLOW — * Model DV -5 Deluge Valve combined with Model CV -1FR Riser Check Valve * *1 -1/2 inch Model DV -5 Deluge Valve combined with 2 inch Model CV -1FR Riser Check Valve TFP142O Page 111 of 14i sure. The supervisory air supply pres- must be maintained at a minimum tern- having Jurisdiction and /or the National sure of 10 plus or minus 2 psi (0,69 perature of 40 °F /4 °C. Electric Code. plus or minus 0,07 bar) can be pro- Heat trac of the DV -5 Valve or its Step 13. Before a system hydrostatic vided by any of the following methods. associated trim is not permitted. Heat test is performed in accordance with Refer to the applicable data sheet for trac can result in the formation of NFPA 13 system acceptance test re- laboratory approval information. hardened mineral deposits that are ca- quirements, the DV -5 Diaphragm • Model G16AC812 (self contained) pable of preventing proper operation Chamber is to be depressurized; the Automatic Supervisory Air Supply The Model DV -5 Deluge Valve is to be Automatic Drain Valve (Item 4, Fig. 2A) described in Gem Technical Data installed in accordance with the follow- is to be temporarily replaced with a 1 /2 Sheet TD126. ing criteria: inch NPT plug, the 3/32 inch Vent Fit- ting (16 - Fig. 2A) is to be temporarily • A maximum 200 psi (13,8 bar) plant Step 1. All nipples, fittings, and de- replaced with a 1/4 inch NPT plug, and air supply in combination with the vices must be clean and free of scale the Diaphragm Cover Bolts must be Model AMD -1 Air Maintenance De- and burrs before installation. Use pipe uniformly and securely tightened vice described in Technical Data thread sealant sparingly on male pipe using a cross -draw sequence. After Sheet TFP1221. threads only. tightening, double -check to make cer- • A maximum 3000 psi (206,9 bar) Step 2. The DV -5 Valve must be tain that all of the Diaphragm Cover nitrogen cylinder in combination with trimmed in accordance with Figure Bolts are securely tightened. the Model AMD -3 Nitrogen Mainte- 2A/2B. Device described in Techni Valve Setting cal Data Sheet TFP1241. Step 3. Care must be taken to ensure that check valves, strainers, globe Procedure NOTE valves, etc. are installed with the flow The dew point of the air or nitrogen arrows in the proper direction. supply, fora system exposed to freez Steps 1 through 12 are to be per - ing conditions, must be maintained be- Step 4. Drain tubing to the drip funnel formed when initially setting the Model low the lowest ambient temperature to must be installed with smooth bends DV -5 Deluge Valve; after an opera - which the system piping will be ex- that will not restrict flow. tional test of the fire protection system; posed. Introduction of moisture into Step 5. The main drain and drip funnel or, after system operation due to a fire. the system piping can create ice build drain may be interconnected provided Step 1. Close the Main Control Valve. up which could prevent proper opera- a check valve is located at least 12 Step 2. C lose the Diaphragm Cham tion of the system. inches (300 mm) below the drip funnel. p ber Supply Control Valve and the Su- The Supervisory Low Pressure Alarm Step 6. Suitable provision must be pervisory Air Supply Control Valve. Switch (Item P3 - Fig. 2A) is factory set made for disposal of drain water. at 5 plus or minus 1 psi (0,34 plus or Drainage water must be directed such Step 3. Open the Main Drain Valve, minus 0,07 bar) on decreasing pres- that it will not cause accidental dam- System Drain Valve, and all auxiliary sure. The Pressure Relief Valve (Item age to property or danger to persons. drains in the system. After water P4- Fig. 2A) is factory set to fully open ceases to discharge, close the System plus or minus 2 psi (1,72 plus or Step 7. Connect the Diaphragm Drain Valve and auxiliary drain valves. at 25 p minus lus or i and it psi (1,72 to plus or Chamber Supply Control Valve to the Leave the Main Drain Valve open. open at a pressure of about 18 psi inlet side of the system's main control Step 4. Depress the lun er of the valve in order to facilitate setting of the p p p g (1,24 bar). DV -5 Valve (Fig. 3). Automatic Drain Valve to verify that it Friction Loss is open and that the DV -5 Valve is The nominal pressure loss versus flow Step 8. Unused pressure alarm completely drained. a Valve switch connections must be plugged. data for the Model DV -5 Deluge Step 5. Clean the Strainer in the Dia- plus Riser Check Valve is provided in Step 9. A suitable automatic supervi- phragm Chamber Supply connection Graph A. sory air (nitrogen) supply, as described by removing the clean -out plug and in the Technical Data Section, is to be strainer basket. The Strainer may be Installation installed in accordance with the appli- cable Technical Data Sheet and set for flushed out by momentarily opening the Diaphragm Chamber Supply Con - 10 plus or minus 2 psi (0,69 plus or trol Valve. NOTES minus 0,14 bar). Step 6. R eset the actuations stem. 1 -1/2 inch (DN40) risers utilize a 2 inch p Y t DN50 Riser Check valve in combina- Step 10. A desiccant dryer, when re. - ion with the 1 -1/2 inch DN40 ) Model quired for the supervisory air supply, is Manual Actuation — Push the operat- ( t be installed between a drip leg and ing lever up; however, do not close the DV 5 Deluge Valve. hinged cover at this time. the Model AMD -1 Air Maintenance De- g Proper operation of the Model DV -5 vice or between the Model G16AC812 Electric Actuation — Reset the electric Deluge Valves depends upon their trim Automatic Supervisory Air Supply and detection system in accordance with being installed in accordance with the the Preaction Trim. the manufacturer's instructions to de- instructions given in this Technical ener ize the Solenoid Valve. Data Sheet. Failure to follow the ap- Step 11. The Supervisory Low Pres- g propriate trim diagram may prevent sure Alarm Switch is. to be. wired to the Step 7. Open the Diaphragm Chamber the DV -5 Valve from functioning prop- supervisory alarm initiating circuit of Supply Control Valve and allow time for erly, as well as void listings, approvals, an alarm panel. full pressure to build up in the Dia- and the manufacturer's warranties. Step 12. Conduit and electrical con- phragm Chamber. The DV -5 Valve must be installed in a nections are to be made in accordance Step 8. Operate (open) the Manual readily visible and accessible location. with the requirements of the authority Control Station to vent trapped air from The DV -5 Valve and associated trim the Diaphragm Chamber. If necessary, Page 12 of 14 TFP1420 • first open the hinged cover, and then the pressure is greater than 250 psi ing a fire condition) must be verified at fully pull down on the operating lever. (17,2 bar), the pressure is to be re- least once a year as follows: SLOWLY close the operating lever, by lieved by partially and temporarily Step 1. If water must be prevented pushing it up, after aerated water opening the Manual Control Station, from flowing beyond the riser, perform ceases to discharge from the Manual however, do not allow the pressure as the follow steps. Control Station drain tubing. Close the indicated on the Diaphragm Chamber hinged cover and insert a new break Pressure Gauge to drop below the • Close the Main Control Valve. Open rod in the small hole through the top of supply pressure shown on the Water the Main Drain Valve. the enclosing box. Supply Pressure Gauge, since this ac- tion may result in tripping of the DV -5 a Open the Main Control Valve one Step 9. Inspect the drain connections Valve. turn beyond the position at which from the Manual Control Station and water just begins to flow from the the Solenoid Valve. Any leaks must be After setting a fire protection system, Main Drain Valve. corrected before proceeding to the notify the proper authorities and ad- • Close the Ma Drain Valve. next step. vise those responsible for monitoring Step 10. Verify the ability for the DV -5 proprietar and /or central station Step 2. Test the deluge releasing to hold pressure as fol- alarms Diaphragm p panel in accordance with the manufac- lows: turer's instructions to energize the So- With the diaphragm chamber pressur- Care and lenoid Valve. ized per Step 8, temporarily close the Diaphragm Chamber Supply Control Maintenance NOTE Valve, and monitor the Diaphragm Be prepared to quickly perform Steps Chamber Pressure Gauge for a drop in The following procedures, inspections, 3, 4, and 5, if water must be prevented pressure. and maintenance must be performed from flowing beyond the riser. as indicated, in addition to any specific Step 3. Verify that the DV -5 Valve has If a drop in pressure is noted, the DV -5 requirements of the NFPA, and any tripped, as indicated by the flow of Diaphragm is to be replaced and /or impairment must be immediately cor- water into the system. any leaks must be corrected before rected. proceeding to the next step. Step 4. Close the system's Main Con - If the Diaphragm Chamber Pressure The owner is responsible for the in- trol Valve. spection, testing, and maintenance of Gauge does not indicate a drop in their fire protection system and de- Step 5. Close the Diaphragm Cham- pressure, re -open the Diaphragm vices in compliance with this docu- ber Supply Control Valve and the Su- Chamber Supply Control Valve and ment, as well as with the applicable pervisory Air Supply Control Valve. proceed to the next step. standards of the National Fire Protec- e. NFPA 25), Step 6. Reset the DV -5 Deluge Valve tion Association Step 11. Replace operated automatic (e.g., ), in in accordance with the Valve Setting sprinklers on the system piping and addition to the standards of any Procedure. then open the Supervisory Air Supply authority having jurisdiction. The in- Control Valve and allow the system to stalling contractor or product manufac- Quarterly Waterflow Alarm Test automatically re- establish its nominal turer should be contacted relative to Procedure air pressure of 10 psi (0,69 bar). Ob- any questions. Testing of the system waterflow alarms serve the Automatic Drain Valve for It is recommended that automatic must be performed quarterly. To test leaks. If there are leaks, deter- sprinkler systems be inspected, the waterflow alarm, open the Alarm mine /correct the cause of the leakage tested, and maintained by a qualified Test Valve, which will allow a flow of problem within the Riser Check Valve. Inspection Service in accordance with water to the Waterflow Pressure Alarm local requirements and /or national Switch and /or Water Motor Alarm. NOTE codes. Upon satisfactory completion of the In order to prevent the possibility of a test, close the Alarm Test Valve. subsequent operation of an over- NOTES heated solder type automatic sprin- Some of the procedures outlined in Quarterly Solenoid Valve Test kler, any solder type automatic sprin- this section will result in operation of Procedure For Electric Actuation klers that were possibly exposed to a the associated alarms. Consequently, Proper operation of the Solenoid Valve temperature greater than their maxi- notification must first be given to the for electric actuation must be verified mum rated ambient must be replaced. owner and the fire department, central at least quarterly as follows: Step 12. Slowly open the Main Control station, or other signal station to which Step 1. Close the Main Control Valve. Valve. Close the Main Drain Valve as the alarms are connected. Step 2. Open the Main Drain Valve. soon as water discharges from the Before closing a fire protection system drain connection. Observe the Auto- main control valve for maintenance Step 3. Test the deluge releasing matic Drain Valve for leaks. If there are work on the fire protection system that panel in accordance with the manufac- leaks, determine /correct the cause of it controls, permission to shut down the turer's instructions to energize the so- the leakage problem. If there are no affected fire protection systems must lenoid valve. leaks, the DV -5 Valve is ready to be first be obtained from the proper Step 4. Verify that the flow of water placed in service and the Main Control authorities and all personnel who may from the Solenoid Valve drain connec- Valve must then be fully opened. be affected by this action must be no- tion increases to a full flow. NOTES tified. Step 5. Verify that the Diaphragm When the Main Control Valve is Annual Operation Test Procedure Chamber pressure has decreased to opened, the pressure on the Dia- Proper operation of the DV -5 Valve below 25% of the water supply pres- phragm Chamber may increase. This (i.e., opening of the DV -5 Valve as dur- sure. increase in pressure is normal, and if Step 6. Reset the electric detection 1 TFP1420 Page 13 of 14 system in accordance with the manu- and then release the ring to allow the factu rer's instructions to de- energize Relief Valve to snap closed. Repeat the Orderin the solenoid valve. Check the Solenoid cleaning procedure as necessary Valve drain for leaks. Any leaks must Procedure be corrected before proceeding to the Limited next step. With reference to Table A on Page 14, Step 7. Slowly open the Main Control Warranty the following items must be ordered Valve. Close the Main Drain Valve as separately: soon as water discharges from the Products manufactured by Tyco Fire drain connection. Observe the Auto- Products are warranted solely to the • Deluge Valve matic Drain Valve for leaks. If there are original Buyer for ten (10) years • Riser Check Valve leaks, determine /correct the cause of against defects in material and work- • the leakage problem. If there are no manship when paid for and properly Coupling Valve to Riser leaks, the DV -5 Valve is ready to be installed and maintained under normal Check k Valvve) placed in service and the Main Control use and service. This warranty will ex- • Single Interlock Preaction Trim Valve must then be fully opened. pire ten (10) years from date of ship- • Supervisory Air Supply ment by Tyco Fire Products. No war- • Solenoid Valve NOTE ranty is given for products or When the Main Control Valve is components manufactured by compa • Accessories opened, the pressure on the Dia- vies not affiliated by ownership with NOTE phragm Chamber may increase. This Tyco Fire Products or for products and increase in pressure is normal, and if components which have been subject DN5inch Riseer r CheCheck valve valve e utilize in in c a a 2 inch the pressure is greater than 250 psi to misuse, improper installation, corro- ti on n with (17,2 bar), the pressure is to be re- sion, or which have not been installed, tion the 1 i/2 inch (DN Model lieved by partially and temporaril maintained, modified or repaired in ac- DV 5 Deluge Valve. opening the Manual Control Station; cordance with applicable Standards of Part Numbers for factory pre- trimmed however, do not allow the pressure as the National Fire Protection Associa- Model DV -5 Valves are provided in the indicated on the Diaphragm Chamber tion, and /or the standards of any other Price Book. Pressure Gauge to drop below the Authorities Having Jurisdiction. Mate - supply pressure shown on the Water rials found by Tyco Fire Products to be Supply Pressure Gauge, since this ac- defective shall be either repaired or Replacement Trim Parts: tion may result in tripping of the DV -5 replaced, at Tyco Fire Products' sole Specify: (description) lge for P/N with e Model option. Tyco Fire Products neither as- l DV -5 Deluge Valve, P/N (see sumes, nor authorizes any erson to Figure 2A). Quarterly Supervisory Low Pres- y p sure Alarm Test Procedure assume for it, any other obligation in Proper operation of the Supervisory connection with the sale of products or Low Pressure Alarm Switch must be parts of products. Tyco Fire Products performed quarterly as follows: shall not be responsible for sprinkler system design errors or inaccurate or Step 1. Crack open the System Main incomplete information supplied by Drain Valve for the Riser Check Valve Buyer or Buyer's representatives. (Item P7, Figure 2A) to slowly relieve supervisory air pressure from the sys- IN NO EVENT SHALL TYCO FIRE tern. Verify that the Supervisory Low PRODUCTS BE LIABLE, IN CON Pressure Alarm Switch is operational TRACT, TORT, STRICT LIABILITY OR and that the low pressure set point is UNDER ANY OTHER LEGAL THE approximately 5 psi (0,34 bar). ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL Step 2. Close the System Main Drain DAMAGES, INCLUDING BUT NOT Valve (Item P7, Figure 2A) and allow LIMITED TO LABOR CHARGES, RE- the system supervisory pressure of 10 GARDLESS OF WHETHER TYCO plus or minus 2 psi (0,69 plus or minus FIRE PRODUCTS WAS INFORMED 0,14 bar) to be automatically re- estab- ABOUT THE POSSIBILITY OF SUCH lished. The Supervisory Low Pressure DAMAGES, AND IN NO EVENT Alarm Switch should return to its "nor- SHALL TYCO FIRE PRODUCTS' LI- mal" condition. ABILITY EXCEED AN AMOUNT Pressure Relief Valve Maintenance EQUAL TO THE SALES PRICE. Over pressurization of the system pip- THE FOREGOING WARRANTY IS ing with air will result in the opening of MADE IN LIEU OF ANY AND ALL the Pressure Relief Valve (Item P4, OTHER WARRANTIES EXPRESS OR Fig. 2A). If the Relief Valve continues IMPLIED, INCLUDING WARRANTIES to bleed air after the system pressure OF MERCHANTABILITY AND FIT - has been reduced to its normal super- NESS FOR A PARTICULAR PUR- visory pressure range of 10 plus or POSE.. minus 2 psi (0,69 plus or minus 0,14 bar), most likely debris became lodged in the seating area. To help clean the seating area, slowly pull up on the ring at the top of the Relief Valve to allow a full flow of air through the Relief Valve, Page 14 of 14 TFP142O DELUGE VALVE (SELECT ONE) P /N's are for American Standard Groove x Groove Connections, and Threaded Ports, For other configurations refer to Technical Data Sheet TFP1305. Specify: (size) Model DV -5 groove x groove Deluge Valve, P/N (specify). 1 -1/2 Inch . .. P/N 52- 477 -1 -919 2 Inch .. P/N 52- 477 -1 -910 3 Inch . P/N 52- 477 -1 -912 4Inch . . . P/N 52 -477 -1 -913 6 Inch .. P/N 52- 477 -1 -915 8Inch P/N 52 -477 -1 -916 RISER CHECK VALVE (SELECT ONE) P /N's are for American Standard Grooved Connections. For other configurations refer to Technical Data Sheet TFP950 for the groove x groove Model CV -1 FR Riser Check Valve. Specify: (size), Model CV -1 FR groove x groove Riser Check Valve, P/N (specify). For 1 -1/2 inch risers, use the 2 Inch Riser Check Valve. 2 Inch .. P/N 59 -590 -1 -020 3 Inch P/N 59 -590 -1 -030 4 Inch .... .. .. P/N 59 -590 -1 -040 6 Inch P/N 59- 590 -1 -060 8 Inch P/N 59- 590 -1 -080 COUPLING (SELECT ONE) P /N's are for American Standard Grooved Connections. For other configurations and finishes refer to Technical Data Sheet TFP1830 or TFP1880. A coupling to attach the Riser Check Valve to the outlet of the Deluge Valve must be separately ordered. Specify: (Size), (Figure #), painted, (description), P/N (specify). For 1 -1/2 inch risers, order an additional Reducing Coupling for the outlet of the 2 inch Riser Check Valve. 2 x 1 -1/2 Inch Figure 716 Painted Reducing Coupling P/N 7162015ES 2 Inch Figure 772 Painted Rigid Coupling P/N 77220ASC 3 Inch Figure 772 Painted Rigid Coupling P/N 77230ASC 4 Inch Figure 772 Painted Rigid Coupling P/N 77240ASC 6 Inch Figure 772 Painted Rigid Coupling P/N 77260ASC 8 Inch Figure 772 Painted Rigid Coupling P/N 77280ASC PREACTION TRIM (SELECT ONE) Specify: (specify size and finish — galvanized is standard) Semi - Preassembled Super- vised Single Interlock Preaction System With Electric Actuation Trim for Model DV -5 Deluge Valves. P/N (specify) 1 -1/2 & 2 Inch Galvanized . . . . P/N 52- 478 -2 -119 1 -1/2 & 2 Inch Black .......... .... . ... P/N 52- 478 -1 -119 3 Inch Galvanized.. . ... . ..... ... . ... .. . P/N 52- 478 -2 -116 3 Inch Black . . . P/N 52- 478 -1 -116 4, 6 & 8 Inch Galvanized . . . P/N 52- 478 -2 -113 4,6 & 8 Inch Black. .. .. P/N 52 -478 -1 -113 SUPERVISORY AIR SUPPLY (SELECT ONE) A device capable of maintaining a nominal system air or nitrogen pressure of nominal 10 psi (0,69 bar) must be separately ordered. Specify: (Specify model and description), P/N (specify). Model AMD -1 Air Maintenance Device (TFP1221) .... ......... . ... .... P/N 52-324-2-002 Model AMD -3 Nitrogen Maintenance Device (TFP1241) . P/N 52- 328 -2 -001 Model G16AC812 Automatic Supervisory Air Supply (TD126) . . . . . .. P/N 52- 150 -1 -001 SOLENOID VALVE (SELECT ONE) A Solenoid Valve compatible with the anticipated maximum water supply pressure must be ordered separately. Refer to Technical Data Sheet TFP2180 for other voltage ratings and NEMA classifications. Specify: 24 VDC, NEMA 2, 4, and 4X, (specify 175 or 250 psi) Solenoid Valve, P/N (specify). 175 psi . . ... .. . P/N 52- 287 -1 -024 250 psi .. .. . . . . . . . ... P/N 52- 287 -1 -124 ACCESSORIES (AS NEEDED) Specify: (description), PN (specify). 600 PSI Water Pressure Gauge P/N 92- 343 -1 -004 Model WMA -1 Water Motor Alarm (TFP921) P/N 52- 630 -1 -001 TABLE A — ORDERING LIST TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 • c -.BIM alisimam ■ =ammo. A — e , ....• =war ∎ �.∎ i> : WM �1111•1•11111 JIM — —i �_ . t° AIR PRODUCTS 7e e 4eacteotcy 71Zaote4actafi eit m AvL eamipt ea,404, 04 tl vte Ptratectca* %%tdeed-Puy O� '�� OILLESS RISER MOUNTED COMPRESSORS Se for Dry Pipe Sprinkler Systems - 1/2" Outlet Connections C V$ - Thermal Overload Protection t - Riser Mounting Kit Included with "AC" Models i -. - Fills System to 40 PSI in 30 Minutes (NFPA 13) - Fully Automatic 1�` — Direct Drive .."._- ., • -s ; , ) - Air Intake Filter(s) r a - Oil Less Piston Compressor \ ,, 5 - UL Listed Pressure Switch r i ` ' < ',; - Bubble Tight Air Check Valve `, " '' - Permanently Lubricated Bearings 60 Cycle Units - 50 Cycle Available, Consult Factory System Model Average Motor Min. Wire Dimensions Weight Capacity Number CFM* H.P. Size ++ L W H (lbs.) (gallon s) ** 110 OL11016AC 1.33 1/6 12 14 9 9 31 215 OL21533AC 2.61 1/3 10 16 9 10 37 335 OL33550AC 4.06 1/2 8 16 11 9 49 425 OL42575AC 5.27 3/4 8 20 14 10 54 610 OL610V100AC 7.40 1 8 20 14 10 55 900 OL900V150AC 10.91 11/2 6 26 17 14 78 1200* OL1200V200AC 14.55 2 10 26 17 14 78 * Average CFM is the average free air delivery - - =.., from 0 to 40 PSIG. �I"-= =��'�- ���� �." 0� ++ Based on 100 foot run. ,Y49 � H Consult Factory for longer or shorter runs. - r , Based on 70 degree F system temp. For other conditions consult factory for pump up times. L w $ - 230 volt only, all other units 115/230 volt. 3 Phase Units available - Consult Factory. Magnetic Line Starters - Thermal Overload Protections w Air Maintenance Device Single Phase i Part # AMD -1 115V 230V Size _ Model The AMD 1 is used when s compressed air is supplied through 1/3 HP 1 HP 00 MGOOA* an existing factory air supply or when Maximum 1 HP 2 HP 0 MGXOA* using tank mounted units. HP 2 HP 3 HP 1 MGO1A* 3 HP 5 HP 1P MG15A* Call 1 -800- 345 -8207 When Ordering a Magnetic Line Starter you mu specify Fax: 610 - 524 -8965 st HP, Voltage and Phase that is supplied to the motor. E -Mail: genairpro @generalairproducts.com R3member - Van. can Find this sheot e nd more e www.GENERALAIRPRODUCTS.com RISER MOUNT OIL -LESS COMPRESSORS * ** GENERAL INSTALLATION INSTRUCTIONS * * AIR PRODUCTS, INC. ALL PIPING AND WIRING TO BE IN ACCORDANCE WITH APPLICABLE STATE, LOCAL IF SYSTEM IS FEEDING FREEZER AND NATIONAL CODES & ROOM OR AREA EXPOSED TO CONNECT TO REQUIRED TEMPERATURES BELOW FREEZING. SHOULD BE APPROVED BY AHJ MULTIPLE CHEC 'SEE DRY AIR PAC INFORMATION.L SYSTEM TRIM VALVES IN FEED LINES CAN RESULT IN LOWER SYSTEM _� PRESSURES DUE TO PRESSURE DROPS 200 F MAX. �:.:.. ) ,,,,,,:,,,, / ACCELERATOR X. � TANK MOUNTED UNITS ARE O T � r �• DPV _ RECOMMENDED FOR USE PRESSURE RELIEF VALVE - \ WITH ACCELERATORS PM VR3P25080 ! I / / / I / P/N AMD - 1 AIR MAINTENANCE DEVICE X. WARNING! DO NOT INSTALL IN AREAS EXPOSED TO 1!2" MINIMUM, TEMPERATURES LARGER IF REQUIRED BELOW 40 DEGREES F BY CODE. OR AREAS EXPOSED - MANUAL DRAIN a- JD'50 )'),YII m i TO WEATHER. CONSULT RECOMMENDED AS FACTORY FOR MINIMUM i WEATHERPROOF OPTIONS. FLEX HOSE 2 OR 7 PIN P1202MP Ir MAGNETIC AUTOMATIC DRAIN (PM FD-1) V REQUIRED FOR ALL RECOMMENDED ON DRIP LEG 3 PHASE UNITS AND SINGLE TO REMOVE EXCESS WATER. COPPER TUBING OR Mb PHASE UNITS 1 HP AND RUBBER HOSE NOT ill:. J--- LARGER. RECOMMENDED DUE MOST MOTORS ARE MULTIPLE TO HIGH TEMPERATURES VOLTAGE. CHECK NAMEPLATE AND HIGH PRESSURE FOR CORRECT INTERNAL DROPS WHEN USED. CONNECTIONS FOR VOLTAGE BEING SUPPLIED TO UNIT. Z RISER MOUNTING KIT I CI - MN AN AIR MAINTENANCE INCLUDED IN COMPRESSOR DEVICE IS USED MOVE SENSING PACKAGE LINE TO SYSTEM SIDE OF SYSTEM CHECK VALVE AND INSTALL PRESSURE SWITCH SETTING RELIEF VALVE (PM VR3P25080) IS 27# CUT IN 40# CUT OUT; FOR HIGHER PRESSURES CONSULT FACTORY PART NUMBERS LISTED ARE FOR ACCESSORY ITEMS RECOMMENDED FOR COMPLETE INSTALLATION - CONSULT YOUR LOCAL DISTRIBUTOR FOR AVAILABILITY OLIS.TCW 10/4/00 Port Full Brass Ball Valve UL /ULc /FM wit �a3 f E f Description Installation Specs FPPI's complete line of Full Port Installation practices consistent Nomenclature and Material: Brass Ball Valves feature with those of the fire sprinkler Part: Material: componenets machined to industry are appropriate for the Nut Steel exacting specifications. Suit- installation of this product. Handle Steel able for water, oil and gas, our Always make sure to porperly Stem Gland Brass Full Port Ball Valves are rated "hold back" the valve and each Stem Packing PTFE 600 PSI for sizes 1/2 " -1 1/2" IPS component being installed to Stem Brass and 300 PSI for the 2" size. Each the valve to prevent over Body Brass valve is complete with plastic tightening or stressing of the Ball Disc Pack PTFE coated valve handle marked valve body. It is also necessary Ball Disc Brass or Forged with, "TRIM TEST DRAIN" as to make sure all components Brass required by UL. Blow out proof are in proper alignment in the End Plug Brass stem. UL /ULc Listed 2R97 (1/4 "- assembly where the ball valve 2" IPS). FM Approved. is present. Improper alignment Part No. Size* of attached components may create stress on the valve 06-838 1/4" IPS leading to valve failure. Use a 06-840 1/2" suitable thread sealant such as 06-842 3/4" PTFE tape or PipeFit Thread 06-844 1" Sealant Paste with PTFE. Never 06-845 1 1/4" use tape and paste together. 06-846 1 1/2" We do not recommend the use 06-848 2" of anaerobic sealants with this product. The materials used in *Full port valves have slightly this sealant type are highly larger "take out" dimensions caustic and may cause failure of than standard port valves. You the synthetic components may need to adjust trim compo- present in this product. DO NOT nents accordingly. USE MORE THAN ONE SEALANT TYPE PER THREADED CONNEC- For questions: TION. DO NOT OVER TIGHTEN 1 800 344 -1822 THREADS. OVER TIGHTENING 1 800 344 -3775 fax WILL CAUSE LEAKS IN THIS AND OTHER THREADED COMPO- http: / /www.fppi.com NENTS. info @fppi.com ©2004 Fire Protection Products, Inc. • ,: ;:8I. _ :_ 'C• _ lib. 't•P !lC1!L!1■1111..114 I— __ _ — — — — — — — % •fz'i / r I 7,21 t tg� "' �`'r,9 r''r; ;, °.�.� ; ° f :Y(,., c �L us ® ILPCBI (vds) SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 009 (UL, FM) STYLE 009V (UL, FM, VdS, LPCB) The FireLock EZ Style 009 and Style 009V couplings are rigid, installation -ready couplings for 4v. . ' protection pipe joining The coupling's uni ue desl n e loose parts, insures consis- ` ` fire p P P 1 g 4 g �: r=�� a- , , ' tent installation and provides substantial gains in productivity IMPORTANT ' FireLock EZ Style 009 and Style 009V couplings are recommended for use ONLY on fire ..` protection systems " -` s PATENTED STYLE 009 LISTINGS /APPROVALS tt§ The information provided below is based on the latest listing and approval data at the time of publication. Listings /Approvals are subject to change and /or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Pipe Size Pressure Rating - psi Pipe Size Pressure Rating - psi Pipe Size Pressure Rating - psi 1I, Ra Rge? N1k'` ' '.grill 11t M > 'i 'C1; s i '. ' & lam` EMI 5 ; 11/4 - 2 175 1 ; 175 175 EZT j 1 16 - 2 300 I 300 300 MT 11/4 - 2 300 300 300 10, 40 1 V. - 4 j 300 300 300 FF, 1 ''% - 4 300 i 300 300 MLT 11/4 - 2 , 300 300 300 BLT 11/4 - 2 ! 300 300 300 FLF 11/4 - 4 ] N/A : N/A 300 ST 11/4 - 2 , N/A N/A j 300 DF i 1 '/ - 4 300 300 ' 300 FLT 11/4 - 2 N/A I N/A 300 STF 11/4 - 4 1 N/A N/A i 300 DT 11/4 - 2 300 300 300 FLTL 1 1 - 2 € N/A : N/A 300 TT 21/4 - 4 ` N/A N/A 300 EF } 11/4 - 4 175 175 I 175 GL j 1 % - 2 { 300 ; 300 300 WLS 1 % - 2 300 300 [ 300 EL 1'/< -2 300 300 300 05 1'/< -2 175 ' 175 175 WST 1'/ -2 175 175 175 ET40 1 1'/ - 2 ; 300 300. 300 G7 11/4 - 2 300 _ 300 300 XL 1 '/ - 2 300 i 300 i 300 EZF , 3 - 4 300 300 300 MF 1 / - 4 300 300 300 STYLE 009V LISTINGS /APPROVALS tt§ Pipe Schedule Size Pressure Rating ¢ � R . . , t ' C .. l 4 '; , � o � §"� F' 4 S. a . 1� , :Pi; ., § 761 mm — — 16 Bar 16 Bar • 232 psi 232 psi ..,.._.._.•,_ § 11/4 -4, 76.1 mm 168ar ...._....,. � .. . � . 16 Bar ._,_.. ...._,�__ ......___._ _ _...._ — 32 - 100 232 psi 232 psi I 1%a — — 16 Bar > 207Bar 32 232 psi 300 psi j 1' /z 16 Bar 207 Bar 40 232 psi 300 psi 10,40 2 — _ 16 Bar 207Bar SO 232 psi 300 psi 3 __ _ -, 16 Bar 207 Bar �� 80 232 psi 300 psi 4 _ _ 16 Bar 207Bar 100 , 232 psi 300 psi t Listed /Approved for wet and dry pipe systems (> -407/-40°C) For rigid pipe connections in systems operating below 07/-18°C Victaulic recommends Style 005 FireLock rigid couplings with Grade "L" silicone gaskets . # Please refer to the Victaulic Field Installation Handbook (1 -100) for details concerning when supplemental lubrication is required § Style 009V couplings are VdS and LPC approved to 16 Bar /232 psi for wet and dry fire protection systems JOB /OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com ,Ctaul1a VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2007 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 1 U. D V 'I ll /ha lf' r /, a (t`.:'' ±(�i :ti.s % ; , ° • l . . r , .. STYLE 009 (UL, FM) STYLE 009V (UL, FM, VdS, LPCB) STYLE 009 DIMENSIONS Max. Max. Allow. Work. End Pipe End @ Bolt /Nut Aprx. Size Press. * Load * Sep. t No. - Size Dimensions - Inches /mm Wgt. Ea. F- Y > Z U 1141 ?bO afl L�3 E ;1 z. 7? I?Xh� ! R _ f($t) I_ _ _ TAT%G'F xw l '•� . �� \\ �.� %nSfOw is,e3 :w lira , 5,/V. 16 1 I — l>:L ■ ■ , 1 t 1 j r 1 r U r /V , I , 1 0 , i r . , ( 1 H E ��, o Ei "►' �' 1'/ 1 660 300 • 649 010 , 3 13 4 93 : 2 86 4 83 1 93 1 5 Ji b _ J 32 I 42 4 2068 2888 2 54 2 - /e x 2 80 125 73 123 49 0 7 \• 1 ' /z 1.900 300 851 010 2 -' /e x 2 3 38 5 16 311 5 07 1 86 1 7 lip 40 48 3 2068 3787 2 54 86 131 79 129 47 0 8 STYLE 009 PRE - ASSEMBLED 2 2 375 300 1329 012 2 _' /e x 2 /z 3 88 5 81 3 59 5 68 1 86 1 9 (STAB IN CONDITION) 50 603 2068 5914 ' 305 99 148 91 144 47 09 21/2 2 875 300 ' 1948 012 4 38 > 6 21 4 08 610 1 87 2 0 Y > 14-Z1 65 730 ; 2068 2 -' /s x2/z 2 - /e x 2 /z 8668 ; 305 , 111 158 104 55 48 09 5 06 6 68 4 73 ' 6 43 1 90 4 3 __ 3 3 500 300 3 2886 i 012 I �1 80 88 9 2068 12842 I 3.05 129 170 j 120 163 48 2 0 4 4 500 300 , 4771 I 017 16 46 8 64 6 00 8 34 210 2 3 t i r � 100 114 3 2068 21230 ' 4 32 2 - =/ e x 21/2 164 220 152 212 53 1 0 *@ t Refer to notes below STYLE 009 JOINT ASSEMBLED STYLE 009V DIMENSIONS Max. Max. Allow. Work. End Pipe End @ Bolt /Nut Aprx. Size Press. * Load ' Sep. t No. - Size Dimensions - Inches /mm Wgt. Ea. u� t a t ;:'79 1 1 � Y= r- Z� �o s ir l aT S 0 1 [ 7}7 ai �a « of •. 1 f to 14:41 I # E . yyI A ,,,lip a, a T r 1 n , .0 a" r ' 1, -° "" r -, I ,...01_4,,I.... :. i' , 1 .i4, x `" ,, .. zh w u ,'c� , mr < f: ..:r4,, , . L, S7 ■ 7 g;fj r_ \ / M � 1ri ► i'' 1 /< 1 660 3 300 1 649 0.10 ) 3 14 I 4 84 2 85 I 4 65 1 91 1 6 J, i _ 32 - - 42 4 { 2068 � 2888 , 2 54 � 2 - M10 x 57 80 1 � 72 118 49 0 7 1 %z 1 900 300 1 851 010 2 _ M10 x 57 3 34 ; 5 06 i 3 13 4 85 1 92 1 7 40 48 3 2068 3787 , 2 54 85 129 80 ) 123 49 0 8 STYLE 009 PRE - ASSEMBLED 2 2 375 ' 300 i 1329 012 2 - M10 x 64 3 91 3 5 66 3 61 ' 5 47 1 94 2 1 (STAB IN CONDITION) 50 60 3 1 2068 5914 3 05 99 144 j 92 139 49 0 9 ' m 3000 i 300 1948 012 .__ 4,57 646 417 618 196 23 761 mm 2 -M10 x64 - t Y Z -1 761 2068 8668 3 05 116 164 106 157 50 1 J 3 3 500 1 300 2886 I 012 2_ M10 x 64 i 515 ) 712 4 73 6 67 1 94 2 6 80 88 9 1 2068 12842 I 3 OS ; 131 181 120 169 49 1 2 4 4 500 l 300 4771 017 6 39 8 74 6.05 l 8.46 2 11 4 6 Is , � 911 2 -M10 x64 _ 100 114 3 2068 j 21230 l 4 32 162 222 , 154 ' 215 54 2 1 * Working Pressure and End Load are total, from all internal and external loads, based on STYLE 009 JOINT ASSEMBLED standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. See pages 3 and 4 of this document for Listed /Approved ratings on other pipe WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 times the figures shown. t The allowable pipe separation dimension shown is for system layout purposes only FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ® 2007 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA jctaulic° IPS CARSON STEEL PIPE - FIRE PROTECTION PRODUCTS 1 V • DU STYLE 009 (UL, FM) STYLE 009V (UL, FM, VdS, LPCB) MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -536, grade 65- 45 -12. Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request. Housing Coating: • Orange enamel (North America) • Red enamel (Europe) Optional Coatings: • Hot dipped galvanized Gasket: • Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183. www.victaulic.com jctaulie VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2007 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA C' I c`�;7' -ter = , _�. •,1� ;1; ti /'te° % , <.is x.70 STYLE 009 (UL, FM) STYLE 009V (UL, FM, VdS, LPCB) GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009 and Style 009V couplings, use FireLock No 006 end caps containing the "EZ" marking on the inside face or No 60 end caps containing the "QV EZ" marking on the inside face Non - Victaulic end cap products shall not be used with Style 009/009V couplings. INSTALLATION Reference should always be made to the 1 -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic corn WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. III 111111IIIIIIIIIIIIIIIIIIII IIIIIIII WCAS- 78KHHG For complete contact information, visit www.victaulic.com 10.60 3999 REV H UPDATED 11/2007 ✓ctaulic-. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2007 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA IPS CARBON STEEL PIPE — FIRE PROTECTION PRODUCTS 10.03 VICTAULIC' IS AN ISO 9001 CERTIFIED COMPANY FireLock® Fittings PRODUCT DESCRIPTION FlreLock' products comprise a unique system specifically designed for fire protection services FireLock full -flow elbows and tees are a CAD - developed, hydrodynamic design that has a shorter center -to -end ti ' dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain . - similar flow characteristics as standard full flow fittings t,t. -- .'i \3, f `/ FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings Use of other couplings or flange adapters may result in bolt pad interference. "' Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. E\ j j i Patented O - See Victaulic publication 10.01 - -1 for details DIMENSIONS -C to E-I No. 001 No.003 No. 002 No. 006 I I ,>\ Fitting Size 90° Elbow 45° Elbow Straight Tee Cap II C to E Actual Aprx. Aprx. Aprx. Thickness Aprx. ? 1 . / 0 f , oo Nominal Outside C to E Weight C to E Weight C to E Weight "T" Weight C . e I y -, Diameter Diameter Inches Each Inches Each Inches Each Inches Each to E - _ o - = = Inches/mm Inches/mm mm LbsJkg mm LbsJkg mm LbsJkg mm Lbs./kg 1 1 660 - - - - - - 0 82 0 3 No. 001 No. 003 32 42 4 - - - - - - 21 01 C 1 1 900 275 12 1 75 09 275 20 082 04 I toE 40 483 70 05 45 41 70 09 21 02 2 2375 2.75 17 2.00 1.8 275 24 088 06 —� v,:;_ = —� - -C �T 50 603 70 08 51 08 70 11 22 03 t o 2 2 875 3 00 3 1 2.25 2 2 3 00 3.6 0 88 1 0 _ E 65 73 0 76 1 4 57 1 0 76 1 6 22 0 5 I + No. 002 No. 006 76 1 mm 1 1 3.000 3 00 3 30 2 25 4 - - - - 76 1 76 I 5 57 1 1 - - - - 3 3.500 3.38 4 0 2.50 31 338 53 088 12 80 88 9 86 1 8 64 1 4 86 2 4 22 0 5 4250 400 57 300 51 400 75 - - 108 mm 108 0 102 2 6 76 2 3 102 3 4 - - 4 4 500 4.00 6 7 3 00 5 6 4.00 8.7 1 00 2,4 100 114,3 102 3 0 76 2 5 102 3 9 25 1 1 5 5563 488 126 325 83 488 157 100 4 125 141.3 124 5 7 83 3 8 124 7 1 25 1 9 159 mm 6.250 5.50 12 6 3.50 9 2 3.50 17.9 - - 1588 140 57 89 42 140 80 - - 6 6 625 5.50 18 3 3 50 11 7 5 50 22 7 1.00 5 9 150 1683 140 83 89 53 140 103 25 27 8 8625 681 255 425 204 6.94 387 113 12.7 200 219 1 173 11 6 108 9 3 176 17 6 29 5 8 ® REGISTERED TRADEMARK OF VICTAULIC - 0 COPYRIGHT 2006 VICTAULIC - PRINTED IN U SA - SKU 2WCAS- 67PJUX 1539 REV F United States - Phone 1 -800- PICK -VIC (1- 800 - 742 -5842) • Fax. 610 - 250 -8817 • e -mail pickvic @victaulic corn Canada • Phone: 905 884 -7444 • Fax. 905- 884 -9774 • e-mail viccanada @victaulic.com Europe - Phone 32 -9- 381.1500 • Fax. 32 -9- 380 -4438 - e -mail viceuro @victaulic be UK • Phone 44(0)1438741100 • Fax. 44(0)1438313883 • e -mail vlceuro @victaulic be , ��� �', �� Central and South America • Phone 610 - 559 -3300 - Fax: 610- 559 -3608 - e -mail vical@victaulic coin Australasia • Phone 86 - 54253300 • Fax 86- 21- 54253671 • e -mail vican@victaulir corn _ — - 10.03 FLOW DATA Frictional Resistance Fitting Size Equivalent Feet/meters of Straight Pipe Actual Straight Tee Nominal Outside No. 002 Diameter Diameter 90° Elbow 45° Elbow Inches /mm Inches/mm No.001 No. 003 Branch Run 1 1 660 1 5 0 8 3 7 1 5 32 424 05 02 1.1 05 1 1.900 2.2 1 1 5.5 2 2 40 483 07 03 17 07 2 2375 35 18 85 35 50 603 1 I 05 26 11 272 2.875 4 3 2 2 10 8 4,3 65 730 1 3 07 33 1 3 761mrn 3.000 4.5 23 11.0 45 761 14 07 34 1 3 3 500 50 26 1 3.0 5.0 80 889 1 5 08 40 15 108 mm 4250 64 32 153 64 1080 2.0 09 47 20 4 4 500 6.8 3.4 16.0 68 100 1143 21 10 49 21 5 5563 85 42 210 85 125 1413 26 1 3 64 26 159 rein 6 250 9.4 4.9 25 0 9 6 158.8 29 15 76 29 6 6625 10 0 50 250 100 150 1683 30 1 5 76 30 8 8.625 13.0 5.0 33 0 13 0 200 2191 40 15 101 40 1 The flow data listed is based upon the pressur e drop of Schedule 40 pipe MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A -536, grade 65 -45 -12 Fitting Coating: Orange enamel • Optional: Hot dipped galvanized This product shall be manufactured by Victaulic or to Victaulic specifications All products to be installed in accordance with current Victaulic installation /assembly instructions Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 2 FlreLock Fittings ® VdS • 1 11L FM SEE VICTAULIC PUBLICATION 10 01 FOR DETAILS STYLE 750 • k b cwl'S 1 g The Style 750 Reducing Coupling permits direct reduction on the piping run. Designed R; ") to replace two couplings and a reducing fitting, the Style 750 features a special reducing gasket for pressure responsive sealing. A steel washer which prevents telescoping of the smaller pipe inside the larger pipe during vertical systems assembly is available upon - T, Ato.,714, request. a. do I art Exaggerated for clarity MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -536, grade 65 -45 -12 Ductile Iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request Housing Coating: Orange enamel • Optional: Hot dipped galvanized and others Gasket: (Specify choice *): • Grade "E" EPDM (All other sizes) EPDM (Green color code) Temperature range -30 °F to +230 °F / -34 °C to +110 °C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL classified in accordance with ANSI /NSF 61 for cold +86 °F / +30 °C and hot +1807/+82°C potable water service NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade "T" nitrite Nitrile (Orange color code) Temperature range -20 °F to +180 °F / -29 °C to +82 °C Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150 °F / +66 °C or for hot dry air over +1407/+60°C * Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Optional: Assembly Washer: Galvanized, carbon steel Bolts /Nuts: Heat - treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A -449 and physical requirements of ASTM A -183. JOB OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA jctaulic° |pS CARBON STEEL PIPE — GROOVED COUPLINGS K0b~K0%s ^- '_- ______-_ -_-____- ___-__-'- ~ u�u "1�`^ �� ~-- ' Reduc i���������� �������U^��� �� �r �� vua' ing c» `~� v~'~ n� SEVICTAULPUBLICATION1O1 FOR DETAILS STYLE 750 ^---- ----- -- � ' _____ ____ ___ _ __ _ _ _ DIMENSIONS ,,, mom ..,2 At.,1€ .. . ,,,,, .4,- ::::,. , .‘,,, 2 , -1; r,i',‘„ „..F$r , ;1.44 r ,, .,,. , i , ,,, .:!;,-.= 'fil .41-' fi,' 182 272 54 5 1 275 1 378 i 64 10 2 Refer to notes on back cover Style 750 Reducing couplings should not be used with end caps (#60) in systems where a vacuum may be developed Contact Victaulic for details v v z ��i | \--� | / it 0 4 \ fa 411, r ` 14\151 = WJ 41 �/, ' : • . www.victaulic.com jctaulacP VICTAULIC IS A REGISTERED TRADEMARK OF VICTAUL1C COMPANY 0 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA - , IPS CARBON:STE PIPE GROOVED COUPLINGS • • • " . ' ' ' , ' • - LL Ub.■ UtIV -' ,, °' it° �` �� §E T VICTAULPUBUcATIONO1 <> 0 R . . FOR DETAILS , STYLE 750 • • • , FLOW DATA HEAD LOSS ' The head loss across Style 750 Reducing coupling is very small and is essentially the same as for • standard short body reducing pipe fittings. • • Equivalent lengths of standard weight steel pipe are shown in the tables. All data is based on water • flowing at ambient temperature. - • FLOW REDUCING - • • , FLOW EXPANDING __ . Equiv.•Pipe - . _ 'Equiv. Pipe , Size - Lengthy ' Size ' .. Length ' * t , Nom1n ; ` :w -'' ,x • - q Nargr� 1 '. e: zk ' t Stn 6 S z �S .•," a+ . ' . e t, 1Inc esfmrn Feet7 t � C 074Imm, i r �:feetfrn , t,. 1 ". , 2, '' 27 50' ` � ' 25 - 1 8 ; 25. " w .50 a 0 8 " i 20- 1rh - ,2,; . 19 a .40 - x SO,,, 'I 06 ' 4 2'67 ::2 :" 1 9 X' � � ''''',,,<.' 2-y:; . ``zi• 65 x `xM, - -', 50 ` 0.6 c., - 2- ,� ' ``' ",„. + n 0 3 1 1 0 7,61 ,<3rrim;; ' ` -y,l 06 • ?i-" % W "'V,,7611,om,1 03 - 50 ._ , h; .go. ^ n,�•, „2 55 r" ; - „)' : .'ie"''rl 35 hBO, , . x x 50 # 1 7 'v:',"" .' ,,a 4 ,.K y „a, • • z '4,<” 7 ' °'.' : 4 T j 3 0 - 4� ..; M' • 65'° , • .1 2 - . • . ,7', -" E\ , ', * 100 ' -1 0.9 889mM . x • 761 ' a 38 2'h x ; •..3; 25 • • 12 ' '65° 80' 08 , (.Y4 2 fi0 = a 4 30 • • - s ,, 100 x ' 50 • • 1 - 8 - ,- 100 N.: 09 65 6g ,.76.1mm•'x.•�889mm, 08' ' ?,a, 1,',`80 bg :y, - ' ,.-4' 1143mm 0.9 1 3,rrim - x _ .;'x7 m • 7 ') )“ ' - ' I sM . 1 8 80 :d 100,,; t 0 8 • s ,s # ,,4` = 30 . q .,•;. A� "St, 33 ' <„ 1125, 5-")•, • „ 09 „ 100 `'` 125' 10 ,.} 6 "'44,',,:-.,A,,,,,',.•%;4',,„.,4 ' ' t; a 6 0 ' s ,;e > .'u ,� `�' a, 64': "< . , E 46 .... `,150 r :,� ; .100 ' 1 8 :-.."<<" ,� •_, d 150,.,4 , 14 � � s.z' _ ,' 1 " i ' k „„,,,,,,,,,v,,•,- '• '125. 14 ;y :.'s `;v11651 :i 14 �165 x-.,.,- r '�` x-. •: = :,__a.u.,a _..'. 'i100 • 18 :'-12.5 ki " 50= 07 •s 8 ,, , ..,f ,, , 6 . y `. 73 ,. >.^ x. 8z ' , 60 . ' , , , `` , „200., - .,,,• :_ 15O _` 2 2 , '150 W ,• < , ,200„' , 1 8 • �. • • www.victaulic:com •:,. , , - ' • • • r vicTAULic IS A REGISTERED TRADEMARK OF VICTA COMPANY 0 2006 VICTAULIC'COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA - �CtauIuCJ VdS SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS _ STYLE 750 rt GENERAL NOTES Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe Maximum working pressure rating based on larger pipe size. Maximum End Load rating based on smaller pipe size WARNING. FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe Figures for standard cut grooved pipe may be doubled These figures are maximums, for design and installation purposes these figures should be reduced by: 50% for 3 /4 — 3 W /20 — 90 mm; 25% for 4 "/100mm and larger @ Number of bolts required equals number of housing segments. Metric thread size bolts are available (color coded gold) for all coupling sizes upon request Contact Victaulic for details WARNING: Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation /assembly instructions Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations US & WORLD HEADQUARTERS CANADA CENTRAL AND SOUTH AMERICA P.O. Box 31 905 - 884 -7444 1- 610 - 559 -3300 Easton, PA 18044 -003] USA 905 - 884 -9774 (fax) 1- 610- 559 -3608 (fax) 4901 Kesslersvilte Road viccanada @victaulic.com vical @victaulic.com Easton, PA 18040 USA EUROPE ASIA PACIFIC 1- 800 - PICK -VIC (1- 800 - 742 -5842) 32 -9- 381 -15 -00 86 -21- 54253300 1- 610 - 559 -3300 32- 9- 380 -44 -38 (fax) 86 -21- 54253671 (fax) 1- 610 -250 -8817 (fax) viceuro@victaulic be vicap @victaulic.com pickvic @victaulic.com UNITED KINGDOM MIDDLE LAS1 www.victaulic.com 44 (0) 1438741100 971 -4- 883 -88 -70 1111111111111111111111111111111111111111 44 (0) 1438313883 (fax) 971 -4- 883 -88 -60 (fax) WCAS- 6QAQRU viceuro©victaulic.be UPDATED 6/2006 06.08 1536 REV H jctaullic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY © 2006 VICTAULIC COMPANY ALL RIGHTS RESERVED PRINTED IN THE USA - - IPS CARBON STEEL PIPE — FIRE PROTECTION FITTINGS 1 0.05 VICTAULIC" IS AN ISO 9001 CERTIFIED COMPANY No. 10 -DR Drain Elbow PRODUCT DESCRIPTION No 10 -DR drain elbows are specifically designed for use on fire protection standpipes The drain is drilled and tapped for a 1" (25 mm) NPT outlet - Constructed of durable ductile iron all sizes conform to the ratings of Style 77 couplings No 10 - DR elbows are supplied with grooves or shoulders. These fittings are not intended for use with Victaulic Plain End couplings. When connecting wafer or lug -type butterfly valves directly to Victaulic drain elbows with Style 741 or 743 Vic- Flange' adapters or Style 744 FireLock Flange adapters, check disc clearance dimensions with the I.D dimension of the fitting o 0 .z. See Victaulic publication 10 01 for details. DIMENSIONS Dimensions C Fitting Size Inches/millimeters to E � ,,rr° Nominal Actual �_ 0 J ° ±_' __� Outside Outside Approximate 0 I P Diameter Diameter Weight Each Inches/mm Inches/mm C - E H P LbsJkg H k— ; I 2 2.875 3 75 2 75 1.68 5.2 C to E I+ — 65 73,0 95 70 43 2,4 3 3500 4 25 275 210 53 80 88,9 108 70 53 2,4 4 4.500 5.00 2.75 2 60 8 8 100 114,3 127 70 66 4,0 6 6 625 6.50 2.75 3 65 18 7 150 168,3 165 70 93 8,5 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A -536, grade 65 -45 -12 Ductile iron conforming to ASTM A -395, grade 65- 45 -15, is available upon special request Fitting Coatings: Orange enamel • Optional: Hot dip galvanized and others. This product shall be manufactured by Victaulic Company All products to be installed in accordance with current Victaulic installation/assembly instructions Victaulic reserves the right to change product specifications. designs and standard equipment without notice and without Incur' Ing obligations ® REGISTERED TRADEMARK OF VICTAULIC - 0 COPYRIGHT 2004 VICTAULIC - PRINTED IN U.S A 1509 REV D Victaulic Company of America • Phone 1 -800- PICK -VIC (1 -800- 742 -5842) • Fax 610- 250 -8817 • e -mad prckvic@v'ctaulic corn Victaulic Company of Canada • Phone: 905 - 884-7444 • Fax 905 -884 -9774 • e -marl. v'ccanada @victaullc.com Vlctaullc Europe • Phone.32 -9- 381 -1500 • Fax 32 -9- 380 -4438 • e -mall, viceuro@v'ctaulic be Vlctauhc America Latina • Phone 610 -559 -3300 • Fax 610 -559 -3608 • e -mall• vical@viclaullc corn s Ct a u I • C e Victaulic Asia Pacific • Phone 65 -6235 -3035 • Fax' 65-6235 -0535 • e-mail vicap @victaul'c.com T , 1 AwvitStarmm FIG. 351 90° Elbow - Straight Fire Pi odllcts Division of Anvil" International ( ;( =; Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet ®•® " t APPROVED For Listing / Approval details contact your AnvilStarTM Representative. FIGURE 351 90° ELBOW STRAIGHT Weight Size A B black goly. B NPS /DN In. /mm In. /mm 1bs./kg lbs. /kg --A—H 1/4 1/2 1 346 0 16 017 8 13 22 0 0/ 0 06 318 9 /16 1 0.25 0 26 t it; /4 24 011 0 1 2 A 1/2 1116 1 /8 0 4 041 I L - - 15 1 29 0 18 019 3 /4 13 /16 1 0.6 0 61 2J 22 33 027 028 1 1 1 0.92 0 95 25 r'4 38 042 643 1 1 1 1 4 1.5 32 29 44 0 65 ii d6 11/2 1 11 2 2 40 33 X 0 86 6 91 2 1 2 3 1 3.2 Si; 40 5/ 1 4 1.5 21/2 1 2 4 9 5.1 65 47 uS 27 2 3 2316 31/2 12 74 80 56 /9 ? 3 3 4 2 3 12 13 160 68 28 5 5 5 7 5 3 41/2 21 — 125 04 114 10 --- 6 3 5 31 33 150 99 1 30 14 15 8 531 6 65 67 200 132 161 29 30 MATERIAL SPECIFICATIONS Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME -B 16.4 (except plugs 1 1 /4 NPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME B16.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW- P- 501(except plugs and bushings the Underwriters' Laboratories, Inc. WW -P -471). NOTE See the Technical Data section for pressure - temperature ratings See AnvilStar Web site for the most current Listings and approvals PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, ,f \, I ANVIL orw A, h0 /l, An1 nn 1n nnv7la. {n• nnm n, nnn +n n+ vnnv Innnl An ,ilCfer •nmm�nn+Mnm t(; = •i Aw StarTM FIG 352 90 Reducing Elbow Fire Products Division of Anvil " International qi );i /ANVIL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet FIGURE 352 90° REDUCING ELBOW �� it* �� Size A B ( D Weigh Size A B ( D 619k APPROVED NPS /DN NPS /DN fn. /mm !n. /mm In. /mm In./mm lbs./kg NPS /DN NPS /DN In. /mm In. /mm In. /mm In. /mm lbs. /kg For Listing / Approval 1 /4 5 /8 3 /4 1 1 0 4 1'/2 1 11 A6 2//16 2 3 7 details contact your 1/2 3 16 /9 ,? 18 21/2 -1, ?, r 62 62 / AnvilStarrm Representative. 3 /8 5 /8 11 /16 1'/16 1'/16 0 34 a 2 1 1 /8 2 2 4 To o 50 , in 66 65 5 3 /4 ' /2 11 /16 1 1 1 0 51 1 1 /II 2 2 2 6 F i 02 's5 41 y9 /5 r5 1 /2 11 A6 15 /16 130 1 0 67 1 15 2 2 2 5 7 I 1 r 5 1i 24 3 5i 0 3 3 vv i 1 +9 i; ;5 : 2 s 3 /4 1 1 3/46 1 1 016 " = 2 1 2 2 2 5 1 20 22 :d f/ iii 034 51 1/2 1 / 6 1'/ 6 1 1', i 1 1 2 1 2 3'/16 3 6 4 -- - 1'i 11 2 7 36 38 0 19 65 49 56 78 'p 2 9 1 3 /4 13/16 11/43 1 /6 1 1 3 3 2 2 3 3 8 9 32 20 22 29 41 41 046 90 86 66 62 86 86 61 H--D 1 1 3/46 1 1 1 12 2 2 2' 3 3 12 t•--8 1 25 ri 23 9,53 5 9 56 2 5 4 '/2 3 /4 1 15/8 15/3 15 2 2 2 3 3 11 15 ` 32 1/ 21 , 069 4 65 56 /0 9 2 92 5 - f - A - ----- ----- - 3A 7/8 15/16 113/16 1 13/16 1.6 1 00 3 2 2 3 3 11 1'/z 20 21 33 4/ 4/ 0 i 60 55 68 92 92 4.8 40 1 1 1 11 11 1.4 31/2 2 2 /i6 3 3'½s 12 25 25 52 47 17 0 65 90 62 68 94 90 5 4 1 1 1 14 1 1 7 2 21 31/2 4 4 20 32 30 32 48 46 0.79 65 73 89 !11 171 9 1 /2 1 1 1 1 2 2 5 3 21 3 4 4 19 15 30 37 35 35 1 / 80 73 87 /11 111 8 6 3 /4 13/46 11/2 2 2 2 2 4 213/46 3 4 4 16 20 33 38 3i 51 1 700 13 84 111 '/7 ; 7 2 I 1 1 2 2 2.1 3 23/46 313/46 41 413/46 19 20 25 7/ 37 51 51 09 00 59 9 114 121 5.6 1 13/46 1 23/46 2 2 3 6 4 21 3 4 4 24 3/ 30 31 52 52 i 1 1 ( 1 ; 100 /3 98 125 125 11 11/2 1 1 2 2' /e 2.6 5 3 31 5 5 21 40 35 38 54 54 12 125 86 98 121 12' 72 1 1 1 23/46 23/46 2 9 8 6 4 51/48 6 6 51 21/42 25 25 44 59 59 13 200 156 106 130 _ !62 162 23 65 13/4 1 1 23/4 2 3 4 32 30 44 60 60 ! 5 MATERIAL SPECIFICATIONS Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME -816.4 (except plugs 1 /4 NPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME B16.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW- P- 501(except plugs and bushings the Underwriters' Laboratories, Inc. WW-P-471). NOTE See the Technical Data section for pressure - temperature ratings See AnvilStar Web site for the most current Listings and approvals PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, nr„ — — — -.nn .... ... ......:: ...... ....... .._ .................�. L..... A.... ..4n4' i 1( Zri/,II` VIL • Am/II -Star FIG. 367 Concentric Reducers Fire Products Division of Anvil' International ai)jANviL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet APPROVED i - For Listing / Approval details contact your AnvilStarTM Representative. FIGURE 367 CONCENTRIC REDUCERS Size A B Weight Size A B Weight black block NPS /DN NPS /DN /n. /mm In./mm lbs. /kg NPS /DN NPS /DN In. /mm Inlmm Ibs./kg 3/4 VI 5 /e 1 6 0 4 1 1 21/4 1 8 29 /5 16 40 0 2 32 i'2 54 1277 • / 11 36 1 0.54 50 1/ Tie 21/46 2 1 15 17 43 024 ,rdnli 47 56 09 75 • 3/4 73 6 11/2 0 63 1 3 /4 2 3 1 20 I 33 0 29 24 4f1 19 51 i 1 9 36 1 0.84 65 2 1 2'1/46 3 15 14 4 0 8 50 25 65 1 1 1 /4 3 /4 1 2 1 /0 11 3 /4 1 5 A6 2 4.3 22 20 2 54 049 29 24 64 1 1 5 36 2 11 3 2 1 1 /46 2 4 25 24 54 0.49 30 53 21 /0 18 1/ 1/2. 1 5 /8 1 2 1 5 /46 21 4.4 15 13 4! 0 4 5 65 24 73 3 /4 Ih 1 5 /8 1 2 2 11/46 211/46 6.5 11/4 %'0 13 41 5 547 50 39 /5 7 4 49 1 1/2 1 3 /4 1 5 4 21/4 1 3 7 8 25 73 44 069 100 65 30 29 3 3 11/4 1 2 15 3 11/46 3 1 /8 7 31 65 77 066 775 79 3 1/2 5,8' 2 2 5 4 1 - 16 3 10 6 76 51 094 127 103 27 774 4 8 2 3 /4 3 /4 2 1.9 4 1 1 /2 3 14 50 70 19 5i 086 6 100 29 8/ 6 3 1 3 /4 2 1.8 150 5 1 1 /4 3 9 36 16 25 19 57 0 33 1 79 90" 8 6 1 1 /4 3 1 /8 29 250 (59 32 98 13 • hex end MATERIAL SPECIFICATIONS Anvil standard and extra heavy cast iron threaded fittings are - Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME-B16.4 (except plugs 1 /4 NPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME B1 6.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW- P- 501(except plugs and bushings the Underwriters' Laboratories, Inc. WW -P -471). NOTE: See the Technical Data section for pressure - temperature ratings See AnvilStar Web site for the most current Listings and approvals PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, i' 4,,, r,0 h0 r,L rb1„ nn fn nnvlln ►01 nn , nr nn non ni ,rni,r Innol AnvJ C1o• rnnrnnnn}o / {„n :1 ; ANVIL ANVii`LSt FIG. :358 Straight Tee Fire Pioducts Division of Anvil" International (z ) ; , /LAIVIL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet APPROVED For Listing /Approval FIGURE 358 STRAIGHT TEE details contact your AnvilStarTM" Representative. Weight Size A B black galv. . NPS /DN In. /mm In. /mm lbs. /kg lbs. /kg 1/4 '1 13 /16 0 22 0 23 f 72 L' I t1 c 1 3e � 1 0 35 0 36 ,illiV 10 74 24 :) 16 0 15 11 11 / 1 6 1 0 56 0.58 /5 1, 29 015 626 3/ 43/16 1 0 84 0 85 20 22 33 038 039 1 1 5116 1 1.3 1.3 25 2 6 38 0 5/ 0 59 1 1 1 2 2.1 3% 29 44 0 9 0 9 11/2 13/46 1 2.7 2 7 h8H 40 33 49 1 2 1.2 2 1 2'/4 4.2 4.3 A -4—A 50 40 57 i 9 2 -- - j -- ` 2 1 2 6 7 6.8 A B 63 4/ 68 3 1 3 2 3 10 10 80 56 /9 .45 46 ' 3 21/46 3 13 14 90 04 8I 6 6,3 4 2 3 16 17 790 68 S5 . ' 7.7 5 336 4 27 28 15 84 1 14 12 1) 6 3 5 41 41 1 9 8 130 19 19 8 53/46 6 79 81 700 132 767 36 37 MATERIAL SPECIFICATIONS Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME -B16.4 (except plugs 1 /4 NPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME B16.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW- P- 501(except plugs and bushings the Underwriters' Laboratories, Inc. WW -P -471). NOTE See the Technical Data section for pressure-temperature ratings. See AnvilStar Web site for the most current Listings and approvals. PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, ` , ecv m ne na nnc nn fn onullela• enm nr nnnt•cf ,,n,,r Innol Anv1IQfnr renrecantath,n Illi,Z;; FIG. 359 Reducing Tee Aiu itStar Fire Products Division of Anvil* International f _iANVIL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet u� ® �c D ----E� APPROVED For Listing /Approval A -iwB i details contact your f f A Representative. D F itt FIGURE 359 REDUCING TEE Size A B C D E F Weight Size A B C D E F Weight black goly black gels. NPS /DN NPS /DN NPS /DN In. /mm In. /mm In. /mm In. /mm In. /mm In. /mm lbs./kg lbs. /kg NPS /DN NPS /DH NPS /DN In. /mm In. /mm In. /mm In. mm In. /mm In. /mm Ibs./kq lbs. /kg 1/4 1 1/44 11 /16 13 /16 11/2 1 11/2 0 57 — 1 /4 1 15 A6 15 /16 15 /16 1 /1 1 11/2 1 1 — 3 17 211 29 29 29 n 26 — 8 24 21 24 38 32 38 0 49 —3/8 11 6 11 /16 3/4 1 11/2 1 0 57 — 1 11 /16 3 /4 15 /16 1 13 /16 1 0.9 — 1 1 /2 10 17 I1 19 29 29 29 026 — /5 U 19 24 32 12 33 11.41 -- /5 :5 3 /4 13 /16 13 /46 11 /16 1 11 /4 1 1/46 0 68 — 1/2 3/4 1 1/46 13 A6 15 /16 1 1 1 0.91 — 20 22 22 1 32 32 21 031 — I 20 2? 21 24 35 32 3/ 041 — 1 1 1 1 1/46 11/46 11/46 1 1 — 1 15 /16 15 /16 15 46 1 14 1 1 1 — 2) 25 25 22 3/ 3/ 35 0.45 — 25 24 24 1 36 35 36 0 49 —1 /4 3 /4 / 1/46 1 1/46 13 /16 11/46 1 1 /6 0.79 — 1 71 11 /16 11 /16 ' 1 13 /16 1 0 89 8 220 2? 24 22 14 3? 24 0 36 — 15 12 U 24 31 22 35 04 — 1 1 11/ 16 11/ 13/ 13/16 11/2 1 0 64 — 3 /4 1/4 13 /16 0/56 1 1/46 1 15 /16 11/46 1 — 15 15 17 I/ 22 22 29 32 0 29 — 1 7 0 20 22 22 24 35 2 37 0 45 — 3 /4 13 /16 13 /16 13 /16 15 46 1 1 1/46 0.75 — 25 1 15 A6 15 46 15 /16 11/2 1 11/2 1 1 — 20 2 2 22 12 24 32 24 0034 — 25 24 24 24 38 37 33 051 -- 3/4 1 /4 9' /1 6 1/46 7/8 11 /16 11 /16 13 ,56 0.62 — 1 /4 11 /16 1 1/46 1 1 1 11/2 1 — "( 8 14 14 22 11 72 0'.8 — P U I/ 29 29 32 35 046 — 3/ 3/ 11/ 11/ 6 15 /16 13 /16 13 /56 1 0 75 — 1 /2 1 1/46 11 46 1 1/46 1 1 1 1 1 76 10 1 7 17 24 22 22 32 0 34 — 15 17 1 1 24 37 32 35 0 46 0 41 1 /2 11/16 11/16 13 46 11/46 13 46 1 0.76 — 1 3 /4 13 /16 1 1/46 15 /16 1 it 11/46 1 1 — /5 U 1/ 22 22 22 = '2 0.34 -- 79 22 12 14 35 5 3' :1 1 15/16 15 /16 13 /14 13/16 1 1 0.99 — 1 1 1 15 /16 1 1 1 1 5 — 25 74 2 _ 2 37 37 35 0 45 — 32 _ 29 _ 29 24 43 43 40 0 38 — 1 1 1 1 1 1 11/2 1 8 — 40 32 32 15 47 47 41 0 83 — MATERIAL SPECIFICATIONS Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME -816.4 (except plugs 1 /4 NPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME B16.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW- P- 501(except plugs and bushings the Underwriters' Laboratories, Inc. WW-P-471). NOTE See the Technical Data section for pressure-temperature ratings See AnvilStar Web site for the most current Listings and approvals PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: PAGE 1 OF 5 Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, ��� DC AI n7 nA nAA nn 4n nn..iln4n• wn... nr nn nln nl vn��. Innnl An�rJO ... • 47..n ��,11 r. IL • FIG. 359 Reducing Tee 4! csonoia r g qz1ARiviL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet D-E-- i 0 0 A APPROVED d �_ D F For Listing / Approval i details contact your - AnvilStarTM' Representative. FIGURE 359 REDUCING TEE (CANT.) Size Icunmi D ©0 Weight roly Size A B C D E F weight block , black goly NPS ON NPS ON NPS DN IMIN®!7�®®®/u� ®I®ufx lbs. kl lbs. kr NPS ON NPS DNNPS D ®enIn. mm In. mm In. mm In. mm In. mm lbs. , lbs. k, /2 15 /16 1 /e 1/16 HIS 1 - 1 /is 1 /4 /1d 1 As 1 /e 1 2 5 - 15 27 2 37 "v 45 - 1 40 24 32 24 49 43 49 1 1 - 1 /[ 1 MI %16 1 /a 1'716 M 1 /16 1.4 - 32 2 M 1 716 716 2 /a 246 2 3 1 - 15 25 74 4" 40 3 3 063 39 3/ 24 54 32 51 L4 - 1/4 H 1/7 1/a 1 1 1/4 1.6 - /7 MI 716 1/4 1 46 1/1d 1 /16 18 - 32 7r 79 4 r 40 44 0 lei 15 27 32 37 37 43 0 83 - /4 13 - 1 /4 /8 1 A 1 /7 1 134 2 - 20 11111111/1111111111 11 S6 1 10 _ < 32 38 38 44 0 88 - 3 /4 1 /16 1 1 /16 1 716 1 4 - 1 ® 1 1 /4 1 /a 1/a 1 3 716 2 1 2.2 20 25 2: 40 37 1 3 065 'Conti 1 7 2 5 32 4 41 4i 1 J 1/4 BINH 1/4 ME8 I /4 1.7 - 10 1 El 716 1/4 1 716 1 /16 1 24 - 32 4t 4; 0 /3 ''2 22 32 41 4/ 48 1 1 - 25 1111111/111111 19/16 1 3 2 M 1 /7 /1d 2 2 2 3 2 - 5 40 0 O ti9 SO 38 24 54 54 57 1..5 - /4 111151Ellig 1 1 4 - 2 /7 1 716 71 2%16 2 2.16 4.2 - 20 3 0.62 65 4/ 24 62 62 56 1.9 - 1 1 . . 19A6 1 716 1 /16 1 5 1 6 1 /2 /16 1 /a 1 /2 2 1 2 /8 3 - .3. 1 75 4v 4J7 43 0 69 0 /1 1 ,2 40 24 35 38 51 47 54 12 - 75 1 /4 � 13/4 1 /I d 1 /4 1.8 - 15 2 11/46 1 716 1 716 2 /4 1 /8 2 /4 3 3 - 32 44 43 44 087 - 30 40 3/ 40 5/ 48 5/ 1 s - 1 7 1 /4 M 716 M 1 716 1 As 2 1 - 1 /4 Mills 1 /8 1 /16 1 /8 1 2 /I6 2.5 - 40 32 27 47 4% 09 32 29 57 46 44 5/ 1 1 - 2 1 716 1 716 M 2 Mill 2 7 - 3 /4 1 /2 WM 716 1 /7 2 1 716 2 /a 3 4 - 50 3/ 3/ 5 1 1 1 20 4r 24 3,6 51 42 54 1 /7 . /16 MI Ind . 1 /7 6 1.5 - 2 1716 1 716 1716 2 /4 1 /16 2 /4 3.3 - 15 17 24 40 0 67 - 50 40 37 40 57 49 57 1 5 - 74 MINH 1716 1/16 1.6 - 1 716 1/16 1/4 13/4 2 27 - 20 1 3/ 0 /7 25 I/ 31 44 41 51 1 2 - 1 1 /4 1 M 15 /16 1 1 1 1 7 - 1/4 WM 1 /8 1/2 1 /8 1 /4 2 /16 2.9 - 32 25 24 ,1, 40 43 0.8 32 29 33 48 44 52 1 3 - 1 h WM 1/4 loam 1 716 2 3 - 2 1 1 /2 716 1 /4 1 /2 2 1 2 /a 2.9 - 40 32 47 J - 50 25 40 14 32 36 5 1 4/ 54 J3 -- 2 1 /16 1 As 3 /16 2 2 ME8 2 8 - 2 1 716 1 /16 1 . 716 2 /4 2 2 /4 3.5 - 50 37 37 22 52 57 13 - 30 10 37 40 57 51 51 16 - 1 /2 1 32 �� /4 � 1716 1.9 - 272 1 71d 1 1/16 2/8 2716 49 - 40 0.88 65 VI= 4' 40 65 60 62 2 2 - 15 1/2 /16 1 /4 . 1 /16 1 /16 1 /i6 2.1 - /7 NE 1 1 Ad 1 /4 1 /a 2 2.5 - 40 74 32 ! 49 43 49 1 15 25 3/ 44 47 51 11 - 3 /4 1 1 174 1 916 174 = I 2.2 - /4 1 1/16 1 87 1 716 2.5 - 1 20 4v" 0 31 4 *a J i0 0 72 37 1 40 38 4+ Cl - 40 /7 /16 /4 1 /4 1 1 /16 1 8 - 1 1 . 1 1 /16 1 /4 1/3 2 2 7 - 15 22 1 9 32 .17 4 3 07 52 25 25 37 44 41 57 1. - 1 /4 �� iggi 13/8 1 /4 1.7 - 1 /4 M 1 /a 1 /16 1 /a 1 /4 2 716 2 9 - 2 5 10 JS 44 0/1 32 29 37 48 44 4 2 13 - 1 ® . 1 /4 HIM 1 716 1.7 - 1 24 1 /4 1 /2 2 1/s 2 3.1 - 25 24 32 47 0 28 - 40 2 32 38 51 46 54 1 4 - 1 71 1 2 1 - 2 1/16 1 716 1/16 2 /4 2/16 2 3.7 - 32 ���� 43 ,5 WE 0 9 - 1 50 40 3/ 40 5' 52 5! 1 / - 1 1 /2 IS 11/4 H 1 /16 1 1 716 2 3 - 32 2 /2 1 /8 1 1716 2x/16 2 2 4 5 - 25 40 S2 49 19 1 - 65 48 44 40 65 60 62 21 - 2 29 - n /16 1/16 1/z 1 /16 l,� 2.3 24 5t? ���� ®® !.;1 45 WI 22 31 38 31 4E 11 1.1 1 72 Hie 1 74 1/16 1 46 1 1 7 1.7 2 3 /4 /8 1A6 1/16 1 /2 1 2 5 - 40 15 37 37 24 43 0 76 0 78 30 20 IM 22 ii 40 38 49 1 1 - /4 INN 174 ii 146 18 - 1 1 M 1 1/16 1/4 1/a 2 27 - 1 20 31 */ 0 ,8J 40 0 25 3/ 44 41 51 12 - w. L1 �! ® . 1 /4 1 /8 1 1 /16 2 2 1 /I6 /16 1 A16 1/a 1 /16 2 i76 3 - ' 32 41 40 47 0 0 37 22 22 37 48 47 52 124 m 174 11/4 1 3 - l 0 24 l it 2 1 5 9 6 P /e 3.2 - PAGE 2 OF 5 Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, -' REV 03 03 06 - 007 ao to www.anvilstar.com or contact your local AnvilStar reoresentative l ' - w .NV 4 A FI G. 3 5 9 Reducing Tee rm. ),) Awl L Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet ® g ® V, i 4 i 8 APPROVED C F � F For Listing / Approval I 1P- , details contact your An Representative. FIGURE 359 REDUCING TEE (CONT.) Size A B C D E F Weight Size A B C D E F Weight blac g black gale. NPS /DN NPS /DN NPS /DN In. /mm In- /mm In. /mm !n. /mm In. /mm In. /mm lbs./kg 16s/kg NPS /DMNPS /DN NPS/ON In. /mm !n./mm In. /mm In. /mm In. /mm In. /mm lbs. /kg lbs./kg 11/2 2 1 11/2 1 2 2 2 3 7 - 1 1 1 1 1 1 2 4 5 - 4n 50 40 38 40 5/ 5 d 57 1 i - •5 25 44 , 4o 59 , 2 - 2 11/2 1 13/46 2 23/46 23/46 5.5 - 1 1 3/46 13 /16 1 21/46 2 23/4 4.8 - or., 55 48 49 4±1 a5 65 62 25 - 21h 21 3'r 22 14 52 66 2 - 11. 2 13 /1 13/5 1 /16 65 1 1 2 7 2 8 65 6; 11/1 15 /1 1 22 1 2 23/46 23/46 5 1 - 7; 22 22 37 38 38 •'d 1 7 1 3 40 24 25 4 +6 56 62 2 3 3 /4 1 A 7 /8 13/46 1 1 1 2 9 - ii ; (Cor1) 2 13/46 13/46 1 2 23/46 23/46 5 9 6 2 20 22 22 3/ 40 40 49 23 -- 50 40 40 43 62 52 65 2 i 2 / 50 1 1 3/46 11 /16 1 1 3 / 4 1 2 3 3 1 4 2 3 / 4 2 2 3 3 3 1 4 - 25 1 7 1 7 3 44 44 5 1 1 4 1. 4 100 70 73 62 94 94 89 6 4 - iCavr, 2 1 1 / 4 1 3/46 13 /16 1 7 1 6 1 1 2 3 4 1 - 1/2 3 2 2 2 3 2 31 7.6 - :0 32 22 3/ 48 48 52 15 , - 75 80 54 5/ 54 79 68 /9 3 4 - 1 15 /16 15 /46 1 2 2 2 3.6 3.7 3 /4 3 2 2 2 3 2 3 8.3 - 43 24 24 38 51 51 54 1 6 1 7 20 86 54 54 54 79 68 7 3 7 - 2 1 11/2 1 23/46 23/46 23/46 5.2 5.4 1 3 2 2 2 31/2 2 3 8.3 - 65 48 48 40 65 65 62 23 2 25 86 54 54 54 /9 68 19 3,8 - 4 3 3 23/46 3 3 31/2 16 - 1 3 2 2 21/2 3 2 /16 31/2 8.5 - 100 76 7s 62 94 94 39 i3 - 92 80 54 54 54 7 73 79 35 - 2 1 1 11/2 23/46 21/2 2 5 3 - 11/2 21/2 11/2 11/2 2 2 23/46 3 7 7 - 1h 50 40 43 4 8 62 54 65 2 1 - 40 63 48 48 54 13 65 /8 3 5 - 2 1 1 1 2 2 2 5 2 - 1 3 21/2 23/46 2 3 2 3/ 8 1 - 65 47 4 4 68 `.' 63 24 - 40 80 54 56 5 4 79 73 / 9 31 - 3 /4 2 1 1 1 2 2 2 51 - 1 1 11/2 23/46 2 23/46 2% 6.8 - 20 65 4/ 44 4/ 68 5/ 68 2.3 - 40 35 38 55 59 ±6 13 3 1 - 2 13/46 1 11/2 23/46 2 23/46 5 - 2 13/46 13/46 2 /16 23/46 2 2 7.3 - 1 50 445 40 443 62 54 65 i 3 - 2 50 40 40 56 65 5 75 33 - 25 21/2 1 /16 1 1 2% 23/46 2 5.4 - 50 21/2 1 1 2 2 23/46 33/46 71 — 65 4/ 44 4/ 68 69 68 2 4 - 65 48 49 54 13 65 /8 3 2 - 1 15 56 13 /46 1 23/46 1 2 4.3 - 3 2 2 2 3 2 3 8.8 - 40 24 24 4 56 49 62 1 9 - 09 54 50 54 79 75 79 4 - 1 2 13/46 11/2 17 23/46 2 23/46 5 - 1 1 15 /16 21/2 2 1 2 5 5 - 2 32 50 47 38 48 62 54 65 2 2 - 25 25 24 54 52 49 68 2 5 - 6 5 21/2 1 1 1 2 2 2 5 4 - 1 1 13 /16 21/2 23/46 2 2 5 9 - 65 47 44 47 60 60 68 24 - 3 32 32 22 54 56 57 70 2 7 - 1 15 56 1 3/44 1 /16 23/46 1 23/46 4.2 - 80 1 1 13 /16 1 23/46 2 /16 23/46 2 6.2 6.3 40 24 24 1 / 56 49 62 1 9 - 21/2 40 35 24 36 59 56 /3 2 8 2,9 13/42 2 13/46 11/2 1 2 2 23/46 4.8 - 65 2 13/46 1 23/46 23/46 23/46 2 6.8 - 40 50 401 38 48 62 54 65 2 - - 50 40 38 5 6 65 67 25 3 1 - 2/ 1 1 1 2 2 2 5.8 - 2 1 1 1 21/2 2 2 3 7 7 - 65 4 / 4/ 4i 68 62 58 2 - 65 4,8 4/ 51 ;,3 68 18 35 lh 3 /4 13 /16 1 1 l 23/4 3.6 - 3 2 2 2 3 3 3 91 - 75 19 27 44 43 38 56 16 - 80 54 )4 54 / 79 79 4 1 - 2 3 /4 'A 1 /8 1 1 1 2 3 6 - 1R 15 /16 1 3/46 23/46 11/2 11/2 2 6 1 6 2 50 20 22 22 44 44 40 51 1 • - 13 24 24 56 48 48 6/ : 8 2..8 1 1 11 /16 1 1 1 23/46 3.9 - 3 /4 15A6 I S/1 6 21/2 11/2 1 2543 6 1 6 2 25 25 17 .44 49 44 5y 1 - 275 24 24 54 48 43 67 9 2 9 11/4 13 /16 1 3/16 1 2 1 2 4 3 - 1 1 1 21/2 2 21/46 2 6 3 6 5 32 22 22 44 52 48 60 2 - 25 25 25 54 52 52 1 68 28 11/,2 15 /16 15 /16 1 23/46 2 23/46 4 4 - 11/4 71/4 1 2 23/46 2 2 6 8 - 2 40 2" 24 47 56 5 67 2 - 3 32 32 32 54 56 _ 56 70 3 1 - 50 2 1 1 1 2 2 2 6 5 2 - 5 1 1 1 23/46 2 23/46 2 7 1 7 3 21/2 50 40 40 4 8 62 5/ 65 2 3 - 40 35 35 56 55 59 /5 3 2 3 3 6 21/2 1 11/2 1 /16 2 2 2 6 - 2 13/46 13/46 23/46 23/46 23/46 21/2 7,8 7 8 65 47 45 47 68 65 62 7 7 - 50 40 40 56 6 5 65 73 3 5 3 s 1 /2 3 /4 3 /4 1 /.4 1 1 23/46 4 - 21/2 11/2 1 2 2 2% 3 8.9 9 21/2 15 19 :5' 44 43 43 56 1 8 - 65 4 8 48 5 /2 /2 18 4 4 2 65 3 /4 7 /8 7 42 1 1 1 2 4 3 - 31/2 2 2 23/46 3 33/4 33/46 11 - 20 22 22 44 44 44 57 19 - 90 60 60 56 86 86 81 5 - PAGE 3 OF 5 Anvil � q + n Listed + Cast & Malleable Iron Fittings For the latest UL/ULCLited and FM Approved l edpressure r ratings, versus s ersus pipe schedule, 7 J i (Z ! 1 ANVIL FIG. 3 5 9 Reducing Tee ARIVII.St Fire Products Division of Anvil" International ,; � � A Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet D-E- .1 ® ® LC APPROVED } I__f_ i For Listing / Approval F details contact your AnvllStarTM Representative. FIGURE 359 REDUCING TEE (CANT.) Size Eil�� D ©© Weight Size A B D E F Weight block roly. black gnly. NPS DN NPS DM NPS DN ®� ®� ® � ®� ®� ®� lbs. ■ lbs. , NPS ON NPS DN NPS ON in. mm In. mm OM= In. mm In. mm lbs. , lbs. k 3 3 4 2 As 2 As 2/16 3 As . 13 - 2 1 As 1 / e 2 2 2 3/a 11 - 80 80 100 08 58 - 2 94 3 8 - 50 43 49 20 68 63 99 51 - 5 3A 3/46 En 486 486 3/4 20 — 2/2 1/s 1,s 2/e 2 As 2 3 12 - (Con!' 'Cunt) 125 83 84 173 1 75 9 - 2 65 48 48 67 13 90 +.3 - 1;4 3 3 /i6 13 — Sil 3 2 2 2 3 3 3 13 — 3? 841 1111/1/1 8 ! 1/111 5 ' — 80 52 62 68 03 79 92 6 7 — 2 3/2 2/46 2A6 21/46 3 /46 3 /6 3/46 13 — 4 2 2 /4 2 /4 3 /4 3 /2 3 /4 13 — 50 90 62 6 62 81 84 87 5 R - 100 10 10 70 9 39 9i 6 __ 2/2 111 1 As HH111 386 11 — 2h 1 A 1 As NEI 2 /16 3'A46 12 — 65 49 84 4 3 65 48 4.% 1,3 90 5 3 - 3 2/46 2 2 33/i6 ® 3/46 12 — 3 2/4 2A 2 /id 3/4 3/e 3/e 13 — 2 80 56 51 6 81 R4 5 3 - 21/2 90 57 54 68 8? / 9? r i 9 — 65 3/2 2 A 2 En 3/46 M . 13 — 65 4 2/4 2/4 2/4 3/4 3/8 3/4 16 — 90 62 60 87 5 7 - 100 /0 /0 10 95 92 95 / 1 — 4 286H®M386En 15 - 5 3/e 3is 2A 4/a 4 22 - 100 69 94 6 9 125 86 99 '? 471 102 10 - 31/2 112 66 2 86 2 2/16 3 86 8 3 - 1/4 86 As 2/8 2A6 2/4 3A6 9.7 - 90 4 02 60 59 18 3.8 -- 32 24 24 6,/ 59 51 84 44 - 2 Mas l'86 21/46 21/46 . 8 7 — 1 /a 1 A16 1 86 2 86 2 86 2 3 84 10 — 10 40 6? 55 3 9 - 40 37 37 68 6i 60 84 4 6 - 2 1 As 1 /8 NH 2 As 386 10 — 2 1 1 2 2 2 3 10 11 65 49 48 r, 84 4 5 - 3 50 4 40 it 63 63 89 4 6 4 8 3 3 2/16 En 2 3 MEI 11 — 8; 2 /2 1 /a 1 b 2 2 3'/46 11 - 80 80 56 (0 91 ; 1 65 18 48 75 73 90 5 1 - 3A En 2 2/16 En 3/46 3h6 14 — 3 2/4 tie En 3/4 3/s 3 13 - 90 60 62 8 87 6 80 57 54 8 3 /9 92 S7 - 4 2 2 As EM1 3 A 3 1/46 En 15 — 4 2/4 2 As 2 /4 3 3/8 3/4 15 — 100 68 68 94 94 6 ; — 100 70 68 70 95 92 95 6 3 - 5 NH 21/26 4 As 4 86 3 20 — h 1 1 2 2 2 3 10 — 123 65 110 110 93 9 — 4 40 3/ 35 6,3 62 60 84 4 6 — 1 Ens 17 2/e 2/8 © © 8 /00 2 As 1A 2/4 2 As 2/e 3/2 11 - 25 ® 1' 6 5; ® 1/11111 ? 6 - 50 17 41 7u 68 67 89 4 9 — 1 /4 1 /4 1 /4 MEI 2 /4 ® 8.6 — 6 2 1 As 2A 3 2 3'/ 6 12 - 32 32 32 5/ 3 9 — 65 5.1 49 67 /6 /3 A 90 5 4 - 1 1 /8 1/1111111111 1/1111111111 3/46 8 4 9 — 3 2 2 2 3 3 3 15 — 3 t ?8 90 90 57 56 68 81 83 92 6 6 — 3 2 1 /s ��� 89 3/16 9 9 — 3 2 2 2 3 3 14 - 90 3 50 a; 81 4,5 - 90 6 62 68 89 8/ 94 6 5 — 90 2h 1 86 1 86 23A ®� 3M 11 — 4 2 2 As 2/4 WE 3 3/4 17 — (C9nr) 65 4 9 1 60 84 5 100 70 68 70 95 95 7 9 - 3 286 NEI 3/16 3/46 nE 12 — 5 3/e 3/46 4/a 4 4 21 - 80 56 81 81 5 4 125 86 84 mum 111 ;i1 10? 9 - 4 2 As 2 As 2 3 1 86 3186 En 14 — 3 /4 1 /4 1 /4 2 86 286 2 3 11 — 100 643 68 E4 94 94 6 5 — 20 32 32 7? 59 59 84 4 8 - 5 �� 2 86 486 4/16 3/4 20 — 1 As As 2/4 MI 2 86 386 10 11 123 65 11 1 10 95 8 9 4 25 22 22 / 0 59 84 41 4 9 3 /4 4 HE 2/4 3 3 3 13 — 300 1 /4 86 5 86 286 286 316 10 11 20 150 70 95 87 95 6 3? 24 24 5° 59 84 4 7 4 8 1 4 2/4 gin 2/4 3A En2 3/4 14 — 1 8 1 As 1 As 2 As 2716 2 /is 3A6 11 11 4 25 100 /0 MEI /9 95 9 5 4 1 - 40 37 3/ 68 62 62 84 4.9 5.1 100 1 /4 4 2 /4 ', 2 /4 in 3 3 /4 14 — 2 1 1 2 2 2 3 12 12 32 100 / 0 70 89 25 5 5 - 50 43 43 it 613 68 89 5 3 5 3 1,h 4 2/4 EH 3/4 1E1E2 3/4 13 - 6 2 2 En 2 As 2 As 3'/46 13 13 40 100 ?:7 95 95 6 1 65 57 51 75 75 90 5 8 5 9 3 2A 2/4 2 As 3/4 3 3/e 14 15 4 80 57 57 68 8 3 33 97 6 4 6 7 100 5 3 3 2 4 4 4 21 - !25 86 86 73 111 111 ID? 9 - 6 3/a 3A 2/8 4 As 4 As 41/46 26 - 150 98 98 73 125 125 103 12 — PAGE 4 OF 5 Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, ,1_,„ L REV 03 03 06-009 ao to www.anvilstar.com or contact your local AnvilStar representative , ..... •�.,.., ., 4 CSOflOfI T F G. 359 Reducing Tee r Z1jARivIL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet it• A " CAL PPROVED C { • For Listing /Approval details contact your AnvllStarTM Representative. FIGURE 359 REDUCING TEE (CONT.) Size A B is D E F Weight Size A B C D E F Weight bl gals black cialy NPS /DN NPS /DN NPS /DN In./mm In. /mm In. /mm In. /mm In. /mm In. /mm lbs./kg lbs. /kg NPS /DN NPS /DN NPS /DN In. /mm In. /mm In./mm In./mm In. /mm ln. /mm lbs./kg lbs. /kg 2 5 3 3 3 4'/ 4 4 22 - 4 2 2 3 4 ie 4 4 5/16 30 - 50 125 84 95 84 /14 108 114 10 - 4 100 7 5 98 103 15 ? 125 14 2 5 33/46 3% 33/46 4 4 4 22 — 100 6 3% 3% 3 5 4 5 34 — 63 ! 15 84 86 8 4 /14 108 114 10 - 150 93 98 90 150 125 130 15 - 3 4 2376 2 3 4 3 4 24 — 1 1% 1 3 2 2 41/2 26 — 80 100 56 56 86 102 95 111 1! - 40 41 40 98 78 70 114 12 - 6 3 4 3 5 5 4%8 31 — 31/2 2% 3 3 3 3 4% 30 - 150 103 86 127 12/ 511 14 - 5 90 6.- 65 9! 28 93 124 14 - 3 23/46 21/2 3 31 31/2 41/4 23 — 123 6 3 3 3 5 5 51/2 43 - 3 80 59 64 83 89 89 /08 ll - 150 98 100 98 130 130 130 20 — 90 4 2 2 3 4 3 4 23 — 8 51,5 5 4 6 6 53/46 66 — 10n 86 102 95 III — 200 1 p. 106 1. 2 1 Al v: II 68 6 v� IG tU�� 1 30 ,�, r' !v6 J< i5 141 30 -- 6 3 4 3% 5 5 4% 29 - 6 1 1 1 3 23/48 2% 43/46 22 - I ;'7 91 102 86 12 1 17 111 13 - 150 32 35 35 97 67 67 113 10 - 2/ 23/46 2 33/46 3 3 4'/4 22 — 2 1 1 3 3 3 4% 25 - 65 53 51 61 81 81 08 !0 - 50 40 46 93 76 76 111 1 - 3 23/46 2 3 3 3 4 24 — 21/2 2 2 3 3 3 4 26 27 80 59 62 83 89 39 108 ii - 95 it 5 97 85 83 121 12 12 5 4 4 2 2 3 4 3 4 21 — 6 3 2 2% 3 3 33/46 4 27 29 125 7 00 !GO 71 70 86 101 95 ill 9 — 150 811 601 50 97 90 90 122 12 13 5 336 3 33/46 41/2 4 41/2 26 — 4 2% 2 3 43/46 43/46 4 32 34 1 84 86 8 5 1 1 4 111 119 1 — 100 7 3 73 98 103 1113 12 15 13 6 3 3 3 5 5 43/48 34 — 5 33/4 3 3 4 4% 5 37 - 150 9/ 98 66 127 i?/ 111 1 5 - 125 85 86 9! 117 11/ 12/ i! — 1'P1 13/46 13/46 33/46 2 2 4 16 — 8 51/2 5 4 6 6 5 58 — 40 46 48 84 68 58 10? 74 2400 130 130 106 162 162 141 25 -- 2 1 1 3 2 2 4 17 — 2 8 5 5 5 6 63/46 6 64 - 50 44 44 87 /5 /6 105 / 9 - 50 200 132 149 182 161 167 167 29 - 2 2 2 3 33/46 3 4 19 — 4 8 5 51/2 5 63/46 63/46 6316 67 — 65 5? 52 86 81 61 103 3 5 - 100 260 132 1441 732 167 167 167 30 - 5 3 23/46 23/46 3 3 3 4 20 — 5 5 43/46 4% 5 53/46 5 6 78 - 80 59 59 83 89 89 108 9 1 - 525 125 106 111 53 741 141 162 35 - 4 2 2 3 4 4 4% 24 — 5 4 43/46 53/46 53/46 5 6% 77 - 100 71 71 86 10 102 ;Hi Ii - 125 1 06 110 132 1d1 141 162 35 -- 6 3 3 3 5 5 4 33 — 6 6 4 43/46 5 5 5 6% 74 — 5551 yr 9/ 85 12/ 72/ 117 15 - /50 150 106 110 136 141 141 162 3E — 8 5 5 4 6 6 53/46 68 — 8 5 5 5 63/46 6 6 92 — 200 132 132 100 162 16 Ili 31 - 200 132 13.E 132 167 167 167 42 — 1'/ 6 3 4 3 5 4 5 35 — 8 2 23/46 2 51 3 3 5 44 — 40 150 98 103 98 130 119 1 16 - 200 50 5 2 52 1 30 6/ 87 149 20 - 2 6 3% 4 3 5' /e 4 5 35 — 2 23/46 2 5 3 3 6 45 — 50 150 9 8 10? 98 130 119 130 56 - 05 59 59 12 2 4 94 152 21 — 2 6 3 3 3 5 4 5' /e 35 — 3 3 3 5 4 4 6 55 - 6 63 !39 98 91 9E 139 119 130 1 6 - 80 /9 /9 1jf1 /14 114 156 25 — 550 3 4 2 3 3% 4 4 4 32 — 8 3 3 3 5 4 4 6 54 — 60 106 71 76 98 103 102 12'c 15 - 200 9 8 72 79 130 1 14 1 156 75 — 3 6 3% 3 3 /e 5 4 51/2 35 — 4 3 3 5 4 4 6 54 — 90 150 98 93 98 110 125 130 16 - 100 /9 /9 1 30 114 114 156 24 - 4 3 2 2 3 3 3 4 32 — 5 4 43/46 53/46 5 5 6 68 - 1110 80 59 61 9 8 96 90 122 14 — 12 ;06 105 132 / 41 141 162 3' - 6 4 4 512 5 5 6 66 — 150 !00 106 ISO X47 141 162 10 — PAGE 5 OF 5 Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, -` 4 CS ? OnOCIa r FIG. 360 Stra Cross r �) ,ApkwIL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet 0 � ® = H,Pi D APPROVED Fr. En,., For Listing I Approval --- ? %' j details contact our Ao.�� Y Min CD AnvilStarTm Representative. cna ;8, { , * ., - 45 FIGURE 360 STRAIGHT CROSS Size A B Weig t black NPS /DN in/mm in /mm lbs/kg 1,2, l 9 /16 2 8 15 22 7. 13 3 /4 1 13/46 1 20 33 22 0 41 1 1 1 1 38 24 0 �2 1 1 1 2.4 32 44 29 ;1 11/2 11 1 3.2 40 19 33 15 2 2 1 51 5/ ,n 23 2 2 11376 81 33 68 4j 3 i 3 3 2 12 90 79 55 5 4 4 31 2 20 00 98 70 8.9 5 41/2 3 /16 31 125 114 84 / 6 5 2 3 48 150 130 9 6 ;', MATERIAL SPECIFICATIONS Anvil standard and extra heavy cast iron threaded fittings are 1 Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME -816.4 (except plugs 1 /4 NPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME 816.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW- P- 501(except plugs and bushings 1 the Underwriters' Laboratories, Inc. WW -P -471). NOTE: See the Technical Data section for pressure - temperature ratings See AnvilStar Web site for the most current Listings and approvals PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Anvil & Malleable Iron Fittings For the latest ^ UL/ULC n Listed and; M Approved pressure ratings, versus pipe schedule, ((i( Awi`it.Star FIG. 383 Hex Bushing Fire Products Division of Anvil' International )1AnNiL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet - _ ..:' 40. APPROVED For Listing / Approval details contact your AnvilStarT"^ Representative. FIGURE 383 HEX RUSHING Size black Weight galv. - Size black galv. 9 NPS /DN Hex NPS /ON lbs. /kg lbs. /kg NPS /DN Hex NPS /DN lbs./kg lbs./kg 1 /4 0.29 0 3 1 /4 1 /e 0.02* 0 02 • ? 6 00 001 3/8 0.29 029 ( '/e 0.05 0 05 • 0 15 3 /8 6 0,02 002 10 1 /4 0.04 0.04 11/4 • 1� 0.3 3 0 3 14 0 14 8 0 a "2 0.02 32 (5 (1 0.39 0.39 88 002 002 3/4 6 0 r n9 ?0 01/ 015 03 0 03 1 0.3 0 3 1/2 1 /4 0.07 0.07 2 0 13 0 :5 S 003 0 03 I/4 047 049 3 4s 0.05 0.05 009 009 • — 10 0.02 (i02 R G5i 027 14 3 1 047 05 6 10 (121 0 23 0 06 O 04 lh 042 047 2 /4 b � 5 0 O 03 1 0 ■ 3/4 4 i (5 0 9 n 1 3 5 20 3 /e 012 012 • 20 02- 0z3 10 005 0 05 1 05 0.52 l/2 01 011 2/ 5 22 (1 24 75 0.05 5 05 1 0.33 0.33 /e 0 21 0.22 • Si 0 15 0 13 6 0 09 0 1 1 /4 019 0.19 • ,4 0 03 009 I 3 /e 0.18 0 19 25 • 10 000 009 112 0 21 0 22 15 01 01 3 /4 0.17 0.17 20 0 08 0.08 MATERIAL SPECIFICATIONS Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME -816.4 (except plugs 1 /4 NPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME B16.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW- P- 501(except plugs and bushings I the Underwriters' Laboratories, Inc. WW -P -471). NOTE. See the Technical Data section for pressure - temperature ratings See AnvilStar Web site for the most current Listings and approvals PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: PAGE 1 OF 2 Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, .. _.. SI_•_. ...... .....�. i. -....I A....a P• ... .w. ...n �I�hIi L FIG. 383 Hex Bushing Awli.Star- Fire Pi oducts Division of Anvil" International fr))) Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet FIGURE 383 HEX BUSHING (cow.) Size We19ht Size Weight black galv. black ply. 1/PS/ON Hex NPS/DN lbs./4 lbs./kg NPS/DAI Hex NPS/DN lbs./kg lbs./kg IA 0 75 08 2 51 5.2 • 6 034 056 50 23 2 1 3 43 0 75 0.78 21/2 49 51 • 10 031 035 65 22 23 1/2 0.77 0.78 5 3 48 49 • • v 35 c 35 ,25 80 2? 2 ; 2 3/4 071 075 31/2 4 4.3 • 50 20 032 0 34 99 78 ,. 1 073 0.76 4 39 4.1 • ,,, 053 334 1 05 ; 2 79 r., 11/4 081 0.83 2 8 83 • • 02 0 3/ 338 - 3 6 30 1 067 068 – 2 1/2 7.7 78 • • 40 0 9 03! 65 9 3 5 1/2 13 ____ 3 7 8 81 • • 13 0.58 — 6 80 3 3! 3 /4 13 1.3 150 31/2 7 1 74 • • 20 .957 C 59 90 32 31 1 12 12 4 6.8 71 • • 21/2 25 039 056 100 :1 3,2 63 11/4 1.2 13 5 5.2 55 • 32 0!6 957 125 24 2 1 13 13 3 16 16 X • 40 059 067 80 , 2 0 92 0.95 4 14 15 • 50 042 043 8 100 6 3 63 th 19 2 200 5 14 14 • • 15 088 0.9 • 125 62 64 3 /4 19 2 6 13 14 • 20 ; 37 088 150 6 57 1 19 19 4 28 — • • 23 9,86 08/ 100 72 — 3 11/4 18 18 5 — — • • 80 32 08 0 82 10 115 — — 1 18 18 250 6 25 — • • 40 081 0.83 156 2 1.9 19 8 22 _ 50 0 36 0 88 200 10 — 2 16 17 4 33 65 0./4 015 12 100 15 * 1 2.6 2.8 300 10 33 33 • 25 12 72 ?30 75 15 11/4 25 2.6 • 16 7 12 „ ' POA 11/2 23 24 • • Not Stocked 31/2 40 i i 71 • Inside Hex 90 2 24 2.5 • 50 „ 1,1 NOTE: Hexagon head or octagon head bushings 21/2 NPS/DN (65 DN) and smaller Reduc- 21/2 26 26 ing one size may be made of malleable iron, ductile iron or steel. Other sizes may be 65 12 1 2 made of cost iron, ductile iron, malleable iron or steel Face bushings 21/2 NPS/DN 3 2 2 (65 DN) and smaller may be made of malleable iron, ductile iron or steel. Face bush- 80 0,89 71 9 ings 3NPS/DN(80 DN) and larger Reducing one size may be made of malleable iron, 1 36 36 ductile iron or steel Face bushings 3NPS/DN (80 DN) and larger Reducing two sizes • Pi 1 5 1 or more may be made of cast or malleable iron, ductile iron, or steel. 1 35 3.6 • According to specifications, hex bushings and cored plugs should be used with 150# malleable 6 1,6 iron and 125# cast iron Solid plugs and face bushings should be used with #250 and #300 „ 1 3.4 35 • Fittings. 40 ; 6 76 4 2 31 32 NOTE: See page PF and page PF-5 for pressure-temperature ratings. • 700 50 74 6 Pressure/temperature ratings vary with material 1 21/2 33 33 • 65 i 5 15 ® g 3 31 32 4> 80 1.4 75 3 2.5 2.6 APPROVED For Listing / Approval 90 11 12 details contact your AnvilStarTM Representative. PAGE 2 OF 2 Anvil Cast & Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV 03 03 06 nn In www.anvilstar.com or r.nntar.t vniir Inral AnvilStar rpnreqentativp 11 Z)r ANVIL Ann Star - FIG. 387 Square Head Plugs (Cored) Fire Products DivIvan of Anvil" International _1f1f�;, niviL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet :4:- �\ f /f APPRO For Listing /Approval details contact your - AnvilStarTM Representative. FIGURE 3870 SQUARE HEAD PLUGS (CORED) Weight Size black gele NPS /ON lbs/kg lbs /kg 3 /4 0.13 014 20 006 006 1 0.25 0.28 0 I 013 11/2 0 39 0 41 32 0 18 010 l 05 052 40 0 23 0 23 2 0 81 0 83 50 83/ 0 13 2/ 1 3 1 3 65 0 6 06 3 1.9 1.9 50 0.85 (8/ 31a 2.5 2.6• 90 1 1 1 _° 4 4 4 130 18 1,8 'POA • Not stocked 0 /e, 1 /4, 3 /e NPS /DN (6, 8 810 DN) plugs furnished in steel. • 1 /2 and 3 /4 NPS /DN (15 & 20 DN) countersunk plugs furnished in malleable iron. MATERIAL SPECIFICATIONS Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME -816.4 (except plugs 1 /4 NPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME B16.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW- P- 501(except plugs and bushings the Underwriters' Laboratories, Inc. WW -P -471). NOTE: See the Technical Data section for pressure - temperature ratings See AnwlStar Web site for the most current Listings and approvals. PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, i i,=; AM /IL Am/II-Star FIG. G. 3 81 Cap Fire Products Division of Anvil° International ) illyvlL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet C)14 APPROVED For Listing / Approval details contact your AnvllStarT"' Representative. FIGURE 381 CAP Weight Size black ply NPS /DN lbs./kg lbs./kg 2 2 5 — 65 1 — 3 41 — 80 l9 — 4 6.4 — 100 5 11 — 125 J a 6 14 15 1511 tit 6 6 8 27 28 200 12 13 MATERIAL SPECIFICATIONS Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME -B16.4 (except plugs 1 /4 NPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME B16.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW- P- 501(except plugs and bushings the Underwriters' Laboratories, Inc. WW -P -471). NOTE. See the Technical Data section for pressure - temperature ratings See AnvilStar Web site for the most current Listings and approvals PROJECT INFORMATION: APPROVAL STAMP: Project: Date: I Phone: Architect / Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL /ULC Listed and FM Approved pressure ratings, versus pipe schedule, r iii D ANVIL , I !le- ill TUBE & CONDUIT ---.. .•,-; --- ..-,-f ' ..ml. 1 7 H I . .0 , , i ...p . . - . .. ' ' 41 f ,, r,?Y ' ' ''' lA * l'' ;::' ' ';■':; 1 -VPV .', i t i' ';''' rt- r -... , . - CP 1 '... .---' . . , ' " ' 14 7,%- ' ' i• 9:;')'-. ..... .., ... . . •, . •Hb1 SCHEDULE-10/40 Schedule-1O/Schedule-40® • Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule -10 /Schedule -40 sprinkler pipe you get a UL listed and FM approved product. Although these products do not require separate approvals, Schedule -10 /Schedule -40 gives you the extra quality assurance you demand. Our Sch -10 (1' / "- 8 ") pipe and Sch -40 (1"- 2 ") pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Sch -40 Specifications Schedule -10 /Schedule -40 product can be NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Lift (24') Wt/Lift (25') In; mm In; mm Lbs/Ft; Kg /m Lbs /Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg "hot -dip" galvanized to meet FM requirements for dry systems in 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 accordance with the zinc coating 25 26.6 2.5 3.05 70 1,120 1,280 1,334 specifications ofASTM A -123. 1 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 Superior Coating 112 "" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 Our advanced formula mill coating of- 2" 2.067 3.650 5.13 30 2,300 2,628 2,738 fers a clean, durable surface. It is also 50 52.5 5.4 763 30 1,043 1,192 1,242 paint -ready for custom color applications 21/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 without special preparation. 65 62.7 8.6 11.73 19 1,048 1,197 1,247 The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe Sch -10 Specifications products up to 4.5000" in diameter is coated with our new Antibacterial For- NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lift (21') Wt/Lift (24') Wt/Lift (25') mula, "ABF ". In scientific laboratory In; mm In; mm Lbs/Ft; Kg /m Lbs /Ft; Kg /m Lift Lbs; Kg Lbs; Kg Lbs; Kg test, ABS proved to have superior resis- 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 tance to microbial colonization of pipe 25 279 2.1 2.70 91 1,213 1,385 1,445 walls, thereby delaying or possibly pre- 11/4" 1.442 1.810 2.52 61 2,319 2,664 2,760 venting the onset of Microbiologically 32 36.6 2.7 3.75 61 1,052 1,208 1,252 Influenced corrosion (MIC) when the 11/2» 1.682 2.080 3.04 61 2,664 3,045 3,172 First Sprinkler System is first installed. 40 42.7 3.1 4.52 61 1,208 1,381 1,439 American Made 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 Meets `Buy American" requirement 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 and is available through distributors in 65 66.9 5.3 8.77 30 1,009 1,153 1,201 the USA, Canada and Mexico. 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 Specifications & Approvals 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.610 11.78 19 2,238 2,558 2,665 Schedule -10 /Schedule -40 pipe are in 90 108.2 8.3 1753 19 1,015 1,160 1,209 compliance with the following: 5" 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 ASTM A -135, and NFPA 13. Both pipe 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 products have a working pressure rating 150 161.5 13.8 34.27 10 885 1,012 1,053 of 300 psi maximum and also meet the 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 stringent requirement for the following 200 209.5 24.5 59.75 7 1,100 1,256 1,309 tests: • Welded Outlets 0 41 /4 . • Hydrostatic Pressure Listed Approved Listed • Side Wall Rupture • Vibration Test 'NCO CO T Flow Control 16100 S. Lathrop • • Harvey, IL 60426 Customer Service: 11350 Norcom Rd. • •Philadelphia, PA 19154 (800) 882 -5543 alhe TUBE 8 CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708 - 339 -1806 S5 - 3 i UL S L ! ED LD i ` o- 9 R21 � = x • �* � Approvals 2008! i - t WOOD - Pipe Hanger Approvals , ' , " :' ULMax UL Test UL Min Wood FM Max FM Test FM Part No Model Rod - 2-.:-. - ,.'°.-,' ount x Min Wood L Size = Dtrectta _ —. Pipe-Size 1 Load ((bs) _Thick s _fie _ Size , Load IIbs) ti ckness � j 8007957 GST 10 3/8" Vertical CPVC 1 -1/2" 300 1 -1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1 -1/2" 300 1 -1/2" 8008957 GST 20 3/8" Vertical 2 -1/2" 850 1 -1/2° 4" 1475 1 -1/2" 8068925 GST 20 -SS 3/8" Vertical 2 -1/2" 850 1 -1/2" 8010957 GST 30 3/8" Vertical 4" 1500 1 -1/2° 4" 1475 1 -1/2° 8009925 GST 25 -380 3/8" Horizontal 4" 1500 1 -1/2" 8022925 SWG 25 -380 3/8" Horizontal 3-1/2" - 4 "* 1500 1 -1/2" 8021957 SWG 20 3/8" Horizontal 2 -1/2" - 3 " ** 1050 1 -1/2" 8073925 SWG 20 -SS 3/8" Horizontal 2 -1/2" 850 1 -1/2" 8139957 SH -GST 20 3/8" 17° Angle off Vertical 3" 1050 1 -1/2" 4" 1475 1 -1/2" 8141957 SH -GST 30 3/8" 17° Angle off Vertical 4" 1500 1 -1/2" 4" 1475 1 -1/2" STEEL - Pipe Hanger Approvals Rods Mount UL: Max F UL Test -UL Min. f Steet M Max FM est FM Mm Steel ` No Palt Model , ee _ _ ` _ Sizo � Direct a , T S 4 of Ptpe e;lze ` Load (fbs) _.' Thickness Rife. Size__ Load (I i Thickness j 8038957 DSTR 1 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8037957 DSTR 1 -1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK 50 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1 -1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH -DSTR 1 3/8" 17 Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8150922 XP 20 3/8" Vertical 2 -1/2" 850 .027" 2" 940 .029" 4" 1475 .105" 8153922 XP 35 3/8" Vertical 3 -112" 1250 .060" 2" 940 .029" 4" 1475 .105" 8294922 SXP 20 3/8" Vertical or up to 45 2" 750 .027" 2" 635 029" 8295922 SXP 35 3/8" Vertical or up to 89 3 -1/2" 1250 .060" 2" 635 .029" 8293957 SWXP 35 3/8" Horizontal 3 -1/2" 1250 060" ct )o cc -j ° m: "ii" - Pipe Hanger Approvals Part No. Model Rod ; Mount UL Max UL Test UL Min FM Max FM Test FM Min Size ' -Direction Pipe Size Load (Ibs) PSI Pipe Size Load (Ibs) PSI 8059957 CST 20 3/8" Vertical 4 "_ 1475 3000 8061957 SWC 20 3/8" Honzontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2 -1/2" 850 Pre -Pour Structural @ 3000psi 8150922 XP 20 3/8" Vertical 2 -1/2" 850 Post -Pour Range II LWC s 35 PCF (Ibs /ft 'SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3 -112° UL and FM tests were performed in compliance with NFPA 13 Standards. 'SWG 25-380 Maximum pipe size in wood timber orjoist allowed by UL is 4' Fastening requirement 5 times weight of water- filled schedule 40 pipe plus 250 pounds. — —__ - SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2 -1/2' SAMMYS' "SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3' d' —` Sammys and Truss -T Hanger° are registered trademarks of ITW Buildex and Illinois SAMMYS Tool Works, Inc. / o f 9 ex - --_ 2008 ITW B � Illinois Tool Works, Inc REV 308 SSS4U www.itwbuildex.com 800 - BUILDEX S V EEL - Luminaire Fitting Approvals t. ,. q 1, , U L I,y7}� • ( ,,; . „ 'FhJf , : , - T<', . r { ,, , . , �l (I LIAtf l°il(.'�. 1 tpo _ t' 3 ; N' _ ,,, 41-,, ((aa� - � ,y � 1 � ,f, ,i- . 1;:. ., yy���(' - q:� y^ ,,, ,, , _ ,, e t ' `, _ t y .l . � ^ a ,y i yyy `t�� f 185 .027" 8150922 XP 20 3/8" Vertical 250 .035" 185 .027" 8153922 XP 35 3/8" Vertical 250 .035" 8181922 XP 200 1/4" Vertical 185 027" 250 .035" 8294922 SXP 20 3/8" Vertical 170 .027" 45° 80 .027" 8295922 SXP 35 3/8" Vertical 250 .060" 90° 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" STEEL - Conduit, Tubing, and Cable Approvals � � ! , G > ""1;:,,..71. � 0 �:.r DUr� spy. �`UL L;Oat) `` UL� � S te@{ � yY `es� r : 1 p Y ,.� � *� � "�f �� � t 1 P r Model : ti T / y ''':;',4,-,.e nc,l;, : � ' ` Llstet Ap atloin Y , ` ;� ''' g .!a ,, r 2 ,i2. ' ,t. .,,,. € , i1, :, �D »3rd. n& s) Ti1CI . 19 n�+. $"x �� t ° ', r 1 J �` 7� 3Y1 ,,F? 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMIT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and ngid PVC conduit 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod UL Listed 4516 - Cable Hanger, Cat. No. C -Z2000 Plenum Rated, Complies NEC Sheet Steel Sizes '-i , - -777'.,-., ' --v7 'S` 1 "'' 3z 7* ar g + 7 r , 6 s �* d '� ` 7 71 ;: — '.- --7 ' � 1 f Siee x e 'T.N �- `r , x a Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 3/16" 1/4" Decimal Equivalent .027" - .029" .035" - .037" .058" -. 060" .058" - 060" .073" - .075" .104" - .105" 188" .250" TRUSS -T HANGER® - Pipe Hanger Approvals Part No. Model Rod Mount UL Load UL Test Listed Application Size Direction Rating (Ibs) Load (Ibs) 8196900 HD38NWZP 3/8" Bottom Chord 1200 6075 Maximum 4" Schedule 40 pipe 8296900 HD38TC 3/8" Top Chord 1200 6075 Maximum 4" Schedule 40 pipe 8297900 HD38BC 3/8" Bottom Chord 1200 6075 Maximum 4" Schedule 40 pipe 8197900 HD12NWZP 1/2" Bottom Chord 1200 6075 Maximum 8" Schedule 40 Pipe 8198900 HD12CZP 1/2" Bottom Chord 1200 6075 Maximum 8" Schedule 40 Pipe 8298900 HD12TC 1/2" Top Chord 1200 6075 Maximum 8" Schedule 40 Pipe 8299900 HD12BC 1/2" Bottom Chord 1200 6075 Maximum 8" Schedule 40 Pipe TRUSS -T HANGER®. Luminaire Fittings Approvals Part No. Model Rod Mount UL Load UL Test Listed Application Size Direction Rating (Ibs) Load (lbs) 8196900 HD38NWZP 3/8" Bottom Chord 1200 6075 Overhead Lighting & Luminaire Fittings 8296900 HD38TC 3/8" Top Chord 1200 6075 Overhead Lighting & Luminaire Fittings 8297900 HD38BC 3/8" Bottom Chord 1200 6075 Overhead Lighting & Luminaire Fittings 8197900 HD12NWZP 1/2" Bottom Chord 1200 6075 Overhead Lighting & Luminaire Fittings 8198900 HD12CZP 1/2" Bottom Chord 1200 6075 Overhead Lighting & Luminaire Fittings 8298900 HD12TC 1/2" Top Chord 1200 6075 Overhead Lighting & Luminaire Fittings 8299900 HD12BC 1/2" Bottom Chord 1200 6075 Overhead Lighting & Luminaire Fittings TRUSS -T HANGER®. Conduit and Cable Approvals Rod Mount UL Load UL Test Part No, Model Listed Application Size Direction Rating (lbs) Load (lbs) 8196900 HD38NWZP 3/8" Bottom Chord 1200 6075 Up to 6" Trade Size EMT, IMC, and Rigid PC conduit 8296900 HD38TC 3/8" Top Chord 1200 6075 Up to 6" Trade Size EMT, IMC, and Rigid PC conduit 8297900 HD38BC 3/8" Bottom Chord 1200 6075 Up to 6" Trade Size EMT, IMC, and Rigid PC conduit 8197900 HD12NWZP 1/2" Bottom Chord 1200 6075 Up to 6" Trade Size EMT, IMC, and Rigid PC conduit 8198900 HD12CZP 1/2" Bottom Chord 1200 6075 Up to 6" Trade Size EMT, IMC, and Rigid PC conduit 8298900 HD12TC 1/2" Top Chord 1200 6075 Up to 6" Trade Size EMT, IMC, and Rigid PC conduit 8299900 HD12BC 1/2" Bottom Chord 1200 6075 Up to 6" Trade Size EMT, IMC, and Rigid PC conduit UL compliance with NEC Standards 4 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER i l / i ' 2 / i IMPERIAL MAX REC. METRIC' 1 thru 4 Inch pipe 1/2 and 3/4 inch pipe PIPE ROD LOAD LBS. PIPE ROD LISTED FOR STEEL/CPVC 5 thru 8 Inch pipe 1/2 3/8 400 10 3/4 3/8 400 20 10 1 3/8 400 25 10 1 1 /4 3/8 400 32 10 11/2 3/8 400 40 10 2 3/8 400 50 10 SIZE - 1/2 thru 8 inch pipe. 21/2 3/8 600 65 10 MATERIAL - Carbon Steel, Mil. Galvanized to G -90 spec. 3 3/8 600 80 10 LISTING /APPROVAL - ° ®�5 203 -EX 2551 31 3/e 600 10 Q Approval guide - Pipe Hangers 4 3/8 1000 100 10 OSHPD OPA -0601 See Wcbsitc 5 1/2 1250 125 12 CONFORMS WITH: Federal Specification WW -H -171 (Type 10, 6 1/2 1250 150 12 Manufacturers Standardization Society ANSI /MSS -SP -58 (Type 10). 8 1/2 1250 200 12 MAXIMUM TEMPERATURE - 650 ° F. • Order Part #300m FUNCTION - Pipe hanger component for use on steel, CPVC or Note t /z" Ring Hanger not <FM> approved copper piping. INSTALLATION - Per NFPA -13. 13R, 13D and CPVC manufacturers instructions. SPECIAL NOTE: When installing on CPVC sprinkler system pipe. Verify that all assembly components are cleaned of any surface oil. PIPE A e FEATURES 8793 25258 * Sized and listed exclusively for use with #310 Surge Restrainer. , � 4 2,362 x7650 * Band edge is offset for EASY pipe insertion. , ,a 22673 26140 B 2 213048 3 2518 * Custom fit swivel nut for better retention in ring body. A ztrz 348x0 +1+50 * Full length knurl on swivel nut for better grip. 3 37645 44311 ORDERING - Part #, pipe size. + gyppi 4 43582 4 9B9 5 60859 86180 5 7 5786 8 3280 6/07 :- :' : TOLCOi www.tolco.com a to, ,dor NIBCO' Revision 10/24/2007 Fig. 909 - No- Thread Swivel Sway Brace Attachment G OUS LISiEO Size Ra nge — 1" bracing pipe. For brace pipe sizes larger than 1", Component of State of use TOLCO Fig. 980. f California OSHPD Approved Seismic Restraints System Material — Carbon Steel, hardened cone point engaging screw -f Function — The structural component of a sway and seismic bracing ` system. I Features — This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2002) Figure 9.3.5.9.1 indicates clear- ly that fastener table load values are based only on concentric load- H ing. No threading of the bracing pipe is required. Open design allows for easy inspection of pipe engagement. Application Note — The Fig. 909 is used in conjunction with the A TOLCO Fig. 1000, Fig. 1001, or Fig. 4 (A) pipe clamp, and joined B together with bracing pipe. Sway brace assemblies are intended to be installed in accordance with NFPA 13 (or TOLCO State of California OSHPD Approved Seismic Restraint Manual) and the manufactur- er's installation instructions. The required type, number and size of fasteners used for the structure attachment fitting shall be in accor- dance with NFPA 13 and /or OSHPD. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions — The Fig. 909 is the structural or transi- tional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 4A, 4B or 4L to form a complete bracing assembly. NFPA 13 and /or OSHPD guidelines should be followed. To Install — Place the Fig. 909 onto the bracing pipe. Tighten the set bolt until head bottoms out on surface. Attachment can pivot for adjustment to proper brace angle. Finish — Plain Note — Available in Electro- Galvanized and HDG finish. Order By — Figure number, pipe size and finish. Dimensions • Weights Hole Size Max. Design. Max. Design Load Approx. Pipe Size A B H Load Lbs. Lbs. w/Washer Wt. /100 1 6 1% 17/32 2015 2765 91 • Available with hole sizes to accommodate up to 3/4" fastener. Consult Factory TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non -TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH 951 737 5599 • FAX 951 737 0330 158 CUSTOMER SERVICE • 800 786 5266 r 0 0 T0Lc,O www.tolco.com a hied m NIBCO 1 Revision 10/24/2007 Fig. 1000 - "Fast Clamp" Sway Brace Attachment c 0 USuSTEO Size Range — Pipe size to be braced: 1" thru 6" Schedule Component of State of „ California OSHPD Approved 10 thru 40 IPS. Pipe size used for bracing: 1" and 11/4 Seismic Restraints System Schedule 40 IPS. Additionally (UL) approved for use to brace Schedule 7 fr- ' ,, 'N, sprinkler pipe up to 4" (maximum horizontal design load N 655 lbs.) Torque requirement 6 — 8 ft. lbs. � Material — Carbon Steel _ Function — For bracing pipe against sway and seismic`. "` disturbance. The pipe attachment component of a sway brace ! i ,, system: Fig. 1000 is used in conjunction with a TOLCO \ `t Fig. 900 Series Fitting and joined together with bracing pipe per i j i ; NFPA 13* or TOLCO OSHPD Approved Seismic Manual, 1 1 1 i forming a complete sway brace assembly. i E it , I Features — Field adjustable, making critical pre- engineering of °' bracing pipe unnecessary. Unique design requires no threading l,% i— / of bracing pipe. Can be used as a component of a 4 -way riser °'`- -, - -_v r_✓' 1 i a i brace. Can be used as longitudinal brace with Fig. 907. Comes -- .,{ \-- -- assembled and individually packaged with illustrated installation ". i - ` ..f.. =, °,- _,,�� instructions — sizes are clearly marked. Steel leaf spring insert / f provided to assure installer and inspector necessary minimum - r{.r; torque has been achieved. , Installation — The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural Maximum Design Load attachment component, Fig. 980, 910 or 909 to form a complete 1" thru 4" pipe size — 2015 lbs. bracing assembly. Follow NFPA 13 and /or OSHPD guidelines. 6" size — 1265 lbs. To Install — Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. Brace pipe can be installed on top or bottom of pipe ,\ to be braced. Tighten hex nuts until leaf spring is flat. It is rec- f `' ommended that the brace angle be adjusted before hex nuts are fully tightened. Approvals — Underwriters Laboratories Listed in the USA / (UL) and Canada (cUL). Included in our Seismic Restraints :rye Catalog approved by the State of California Office of Statewide f" '� � / Health Planning and Development (OSHPD). For additional _ s " �'- ,F'; , 7 load, spacing and placement information relating to OSHPD ' `�, ' 1 �' projects, please refer to the TOLCO Seismic Restraint Systems ' \�` ,...._, ,,*1 Guidelines. �� �i��' Application Note — Position Fast Clamp and tighten two hex Lateral Brace nuts until leaf spring flattens. A minimum of 1" pipe extension % � ` beyond the Fig. 1000 is recommended. Finish — Plain Note — Available in Electro- Galvanized and HDG finish or Stainless Steel materials. Order By — Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non -TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92979 • PH 951 737 5599 • FAX 951 737 0330 CUSTOMER SERVICE • B00 786 5266 165 0 (b0 1"DLCD www.tolco.co ahri1of Revision 10/24/2007 Fig. 907 - 4 -Way Longitudinal Sway Brace Attachment C US LISTED Size Range — 1" x 1", 1" x 1 and 1 x 11/4" bracing pipe. Component of State of California OSHPD Approved Material — Carbon Steel, hardened cone (or cup) point engaging screw Seismic Restraints System Function — For bracing pipe against sway and seismic disturbances, Functions as a longitudinal brace connection when attached to a lateral brace pipe. Bracing con- , nection must be positioned as close as physically possible to the braced pipe (No A more than 3" away). Must be used only with TOLCO bracing components. When . used in conjunction with TOLCO Fig. 1000, this combination bracing restricts piping f movement in tension and compression both laterally and longitudinally. Approvals — Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL). j ' , i Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, .� �,` ,• Y . ,' i i y � .. ,, .. 11., ; . Cup spacing and placement information relating to OSHPD projects, please refer to the l , „.a v ; Point TOLCO Seismic Restraint Systems Guidelines. = 'l," "� / Installation Instructions — The Fig. 907 is a transitional component of a longitudi- ,,'., ,,{ ,r/ ii ' nal 4-way sway brace assembly. It is intended to be installed with the longitudinal B ` \,'- Y Y Y 9� E , ...; and lateral "bracing pipes ", TOLCO structural attachment fittings, Fig. 909, 910 and 980 and the Fig. 1000 TOLCO "braced pipe" fitting, to form a complete bracing assembly. NFPA 13 and /or OSHPD guidelines should be followed. To Install — Attach the Fig. 907 over the lateral "bracing pipe" to within 3" of its position relative to the "braced pipe" connection. Adjust brace angle and tighten bolts until heads bottom out on surface. Finish — Plain Note — Available in Electro- Galvanized and HDG finish. Order By — Figure number, bracing pipe sizes and finish. \ if ...._,, , Tolco Fig. 980 Tolco Fig. 980 1 �(� Tolco Fig. 1000 ,--- Tolco Fig. 907 Tolco Fig. 1000 Tolco Fig. 907 i l---- l \ Dimensions • Weights Tolco Fig. 980 Max. Design Approx. / Tolco Pipe Size A B Load Lbs.* Wt. /100 Fig. 980 1 x 1 4 4 655* 103 1 x 1 5 4 655* 107 1 x 1 5 5 655* 109 • Load will accommodate up to 4" pipe at maximum spacing. TOLCO brand bracing components are desgined to be compatible ONLY with other TOLCO brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO brand bracing components, in the instance that such TOLCO brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non -TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA, CA 92879 • PH 951 737 5599 • FAX 951 737 9330 CUSTOMER SERVICE • 800 786 5266