Loading...
Permit A CITY OF TIGARD ' 4. DEVELOPMENT SERVICES BUILDING PERMIT W PERMIT #. e e - ...: BUP97 -0090 !�- 13125 SW HaII Blvd., Tigard, OR 97223 (503) 639 -4171 DATE ISSUED: 02/25/97 PARCEL: 2S103AA -00101 SITE ADDRESS, e - : 10865 S!^! WALNUT ST SUBDIVISION= ZONING: R -4n 5 BLOCK.. ..... a.. e. LOT...... .......g REISSUE2 FLOOR AREAS EXTERIOR WALL CONSTRUCTION — CLASS OF WORK.: ALT FIRST....: 0 sf N: S: E: W: TYPE OF USE... :COM SECOND...: 0 sf PROTECT OPENINGS?-- - TYPE OF CONST -:? o... 0 sf N: So E: Wo OCCUPANCY GRP.:E1 TOTAL . 0 sf ROOF CONST: FIRE RET ?: OCCUPANCY LOAD: 0 BASEMENT.: 0 sf AREA SEP. RATED: STORa: 0 HTa 0 ft GARAGE...: 0 sf OCCU SEP. RATED. BSMT? : MEZZ2g REDD SETBACKS REG.0 I RED FLOOR LOAD... - : 0 psf LEFT: 0 ft RGHT: 0 ft FIR SPKl_: SMOK DET.. : DWELLING UNITS: 0 FRNT: 0 ft REAR: 0 ft FIR ALRM: HNDICP ACC. BEDRMS: 0 BATHS: 0 IMP SURFACE: 0 PRO CORK: PARKING: 0 VALUE.. $: _`7'70102 Remarks: �e- roof Owner: FEES TIGARD TUALATIN SCH. DIST 23J type amount by date recpt 13137 SW PACIFIC HWY PRMT ;`> 875.50 B 02/25/97 97- 290820 SPCT $ 43.78 B 02/25/97 97- 290820 TIGARD OR 97223 Phone ;#: Contractor: -- LEIGH' S ROOF SERVICE, INC F=1TTN : RAY PETTY P 0 BOX 14 MCMINNVILLE OR 97128 -0014 Phone #: 472 -0031 $ 919028 TOTAL Reg #. a E 000020 REG!UIRED INSPECTIONS - -- This pergit is issued suh sct to the reTlatic "s contained in tha Misc. Inspection Tigard Municipal Code, State of Ore. Specialty Ccees and all ether Ponding before t applicable laws. All work ill be done h accordance with Dryrot after tea approved plans. This pereit will expire if caork is not started within 183 days of issuance, or if pork is suspended for core than 186 days. Al. • Permittee Si tore: ,� jc,.- Issued B y : / 1 / _ Call for inspection — 639 -4175 CITY OF TIGARD 1 COMMERCIAL Permit #: 6o eq7 -cm 13125 SW HALL BLVD. 1,, Date Rec' : z5-el 7 TIGARD OR 97223 RE- ROOFING PERMIT Bldg: $ V- 503 - 639 -4171 X304 APPLICATION Plan Chk: $ F -503 -684 -7297 St. Sur. Chrg:$ 1-01% Incomplete or illegible applications will not be accepted 4 Name of Development/Business Date work is to begin: 2/97 Date Completed 7/97 Fowler Middle School Weather permitting JOB Address NEW ROOFING ASSEMBLY SITE 10865 Walnut - Tigard Building Use Education STEP 2 Name New Roofing Material Documentation (UBC Appendix 15) Tigard - Tualatin School Dist. 23J Please Fill Out Applicable Sections & OWNER Mailing Address Attach Copy Of Roofing Specifications 13137 S.W. Pacific Hwy See Attached Specifications City/State Zip Phone Tigard, OR 97223 620 - 162C Name Listed Assembly: Leigh's Roof Service, Inc. ROOFING Mailing Address 1. Specification #: R6692 (N) CONTRACTOR P.O. Box 14 /355 Alpine VP (All licenses City/State Zip Phone Manufacturer: Tr emco have to be McMinnville, OF, 97128 472 -0031 current at State Constr.Contr. Board # Exp Date UL Classification:Class "A" time of 0 01.T — 3 -15 -97 issuance) T Bus. Ta or Metro Lic # Exp.Date (or) Warnock Hersey: X9 _ STEP 1 -- 9 f7 2 %2 77f a•Z-3/-9l Listed UL Building Materials Directory Page #: S� Describe =work to be done: (circle one) Listed Warnock Hersey Directory Page #: CRE -ROOF (PROVIDE COPY OF ASSEMBLY) A. Existing roof covering to be REMOVED and deck (OR ) repaired - PROCEED to STEP # 2. 2. ICBO Research #: B. Existing roof covering to REMAIN: NOTE: APPLICANT Dated: "MUST SUBMIT AN ENGINEER'S REVIEW OF THE ROOF STRUCTURAL ( PROVIDE COPY OF ASSEMBLY ) ELEMENTS. REVIEW SHALL BEAR THE SEAL/STAMP OF THE ARCHITECT OR ENGINEER LICENSED IN OREGON . 3. SPECIAL PURPOSE ROOFING: WOOD SHAKES* (PROCEED TO STEP # 2) *REVIEW REQUIRED BY PLANS EXAMINER * REPAIR (MAJOR) WHEN STRUCTURAL ELEMENTS OTHER THAN SHEATHING IS TO BE REPLACED A PLAN REVIEW IS REQUIRED. 3 SETS OF PLANS MUST $ 276, 280.00 VALUATION OF PROJECT: BE SUBMITTED. g75.5�� t q , )J / iq „1( Existing Deck Type: �S I I HEREBY STATE THAT THE ABOVE INFORMATIO IS TRUE AND AC r RATE . Combustible ( ) SIGNED: A .y L4 _ I / -fra Non - Combustible (xx DATE: Proof cod 1/97 (DST) wrc T byo Sri GOTCHALL & ASSOCIATES u`IRUCPUHAL ETKW(I UKS (MAID 1.. GOTCHAI.L, P.Y.. 2328 8.11 WASHINGTON STRRBT C:IWU U. MU N.W.LL, PJ ., Assoclare MIkWAUaW. OIWLJC)N 97222 PHONE (5D3) M9 -5915 PAX 0503) 632-0668 PHONE MEMO CLIENT Tigard Tualatin school District PROJECT Re roof at rowler Junior High TO Ron Hudson BY Gerald L. Gotchall DATE November 20, 1996 MESSAGE : Question regarding extra weight for reroofing Two areas at school, one with steel joist and deck and second with wood purling and Tectum Steel deck areas ....original project had 3.5 pet for roofing, 5.0 for ceiling and 1.9 pet for misc. Ceiling probably weighs about 2.5 pet, leaving 2.5 psf to spare added to the 1.9 psi gives about 4.4 psf in excess capacity. Therefore adding 4.5 psf for reroof would be acceptable. Wood purlin and Tectum areas ... original project had 3.5 psf for roofing and 1.7 pef for misc., no ceiling loads. Since project was built, the design values for lumber have been lowered, therefore we do not see excess capacity for these areas. Addition of reroof weighing less than 2 pef without tearing off existing roof would be acceptable. The 4.5 psf roof system proposed would be acceptable if the existing built up roofing were removed. All proposals overload the existing roof system, but only by less than 2 psf and wo consider that margin to be acceptable. end • C64. 1L (�11d ( �r ✓1Gfl .•41.1100r- .OVAe Ornr. r 7 0. w� I COPIES TO1 ` „ ' - _ r :.• ti:)( � - 3 0 -9' /k+wlei9o.p4 S fi 3 -, go egee iertki, fa - ii.e lV , % , 1 CITY OF TIGARD BUILDING INSPECTION DIVISION U/ � _ / ..„-de 24 -Hour Inspection Line: 639 -4175 Business Phone: 639 -4171 i Date Requested: 1/V p / " 3- 1 1 q �' J / ,1 / A.M. P.M. MST: Location: `D 0 W S S-60 a14 L4I q BUP: ! 7 (JO 9 Tenant: F irliL i - Suite: Bldg: MEC: Contractor: A.5 J Phone: 472-' Q0 31 PLM: Owner: Phone: a w s 3- • ELC: 1 5couQ.Q.Q ✓ �-tc ., w i - c -elt I' 4,.. , ! ' / / ELR: I i ' ; i._ ^ f WU -, / f#, , 4 s ' 6-- aktf; BUILD l G ' B ., : 1 't PLUMBING MECHANICAL ' LE ' TRICAL SITE Site Pos earn , n Post/Beam Post/Beam Cover /Service Sewer /Storm Footing �X UndFl/Slab Rough -In Ceiling Water Line Slab Framing Top Out Gas Line Rough -In UG Sprinkler Foundation Insulation Sewer Hood/Duct Reconnect Vault Bsmt Damp Drywall Storm Furnace Temp Service MISC. Masonry Ceiling Rain Drain A/C UG Slab Shear /Sheath Fire Spklr /Alm Crawl/Found Dr Heat Pump Low Volt roved Approved Approved Approved Approved Appr /Sdwlk Not Approved Not Approved Not Approved Not Approved Not Approved '' Ft� FINAL FINAL FINAL FINAL • ❑ Call for reinspection ❑ Reinspection fee of $ required before next inspection ❑ Unable to inspect Inspector: ‘ /�icr Date: 0 — / Z 2 3 Page of