Permit CITY TIGARD MECHANICAL PERMIT DEVELOPMENT SERVICES PERMIT #: MEC2005 -00165 41 DATE ISSUED: 4/11/2005 13125 SW Hall Blvd., Tigard, OR 97223 503 - 639 -4171 PARCEL: 2S103AB -00404 SITE ADDRESS: 11305 SW WALNUT ST ZONING: R -4.5 SUBDIVISION: LOT: JURISDICTION: TIG Project Description: Installation of A/C, gas furnace & gas fireplace. 4/13/05: Added 2nd gas furnace.4 /18/05: Added, (5) fans, gas stove, water heater & dryer. CLASS OF WORK: OTR FLOOR FURN: EVAP COOLERS: TYPE OF USE: SF UNIT HEATERS: VENT FANS: 5 OCCUPANCY GRP: R3 VENTS W/O APPL: VENT SYSTEMS: STORIES: BOILERS /COMPRESSORS HOODS: FUEL TYPES 0 - 3 HP: 1 DOMES. INCIN: 3 - 15 HP: COMML. INCIN: MAX INPUT: BTU 15 - 30 HP: FIRE DAMPERS ?: 30 - 50 HP: REPAIR UNITS: GAS PRESSURE: 50 + HP: WOODSTOVES: FURN < 100K BTU: 2 AIR HANDLING UNITS CLO DRYERS: 1 FURN > =100K BTU: <= 10000 cfm: OTHER UNITS: 5 > 10000 cfm: GAS OUTLETS: 0 Owner: FEES HARRIS, JAMIE Description Date Amount 11305 SW WALNUT TIGARD, OR 97223 [MECH] Permit Fee 4/11/200E $72.50 [TAX] 8% State Surcha 4/11/200E $5.80 [MECH] Addl Permit 4/18/200E $39.90 Phone: 503 -591 -1337 [TAX] 8% State Surcha 4/18/200E $3.19 Total $121.39 Contractor: SERVICE NOW OF OREGON INC 404 SE BEAVERCREEK RD #228 OREGON CITY, OR 97045 REQUIRED ITEMS AND REPORTS Phone: 503- 655 -7558 Reg #: LIC 161582 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain copies of these rules or direct questions to OUNC by calling 503 - 246 -6699 or 1- 800 - 332 -2344. Issued By: f Z.d2. Permittee Signature: Call 503 - 639 -4175 by 7:00 a.m. for inspections that business day. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. N Mechicr_Permit , I ! • g . 1 E D '==!:;;''r!",,,r71W;:iie,4r.V.*.';,':,,,,;.,.;;.,,r..; ^.,:•,',..,, . . .,,.' , -. . City of • *art Reeaived - -40 ,,,-.7 L ), Pcmut No.:-\E„: C 13125 Sw Hall 131vd„ Tigard, OR 97223 APR 0 8 2005 , frir . , , , Date/By: , ci Plan Review Phone: 503,639 4171 Pax: 503.598.1960 ti Oilier Permit: Inspection Line: 503.639.4175 CITY OF TIGARD .-'&11;iliii', DaEBY: ,,.....,,.. Mac ReadWBy: FM Ed See Page 2f Internet: www.atigard.or us BUILDING DIVISIO - : Not ificcumolind: supplement-a/Information rg,PPMIg ,,.) ;,:"1 j't . - ). '‘-r-P , i , cOki'imgka - xL*ttwaitottet;,")ior9 - ixom ti „;..:,..W6 , ,.s :'' .,.1 , 'PIP ' • . ....P. ;-.''. - ‘. ,- . . ,_,-,. . , ' ...'-:. , .: . ,„; .ii,:''': .,-, ll , n ^k '4;, , Mecligniedl permit fees° arc based on the value of the work 0 New construction - 4.3 ArlditiOn/alteration/replaccment performed. indicate the value (rounded to the nearest dollar) of all 0 Demolition 0 Other: mechanical materials, equireni labor, overhead, and profit. 7' '" if'd: -it iiprinVi::f ii ..,..;Ae,' Value. $ 14:a5.72F,iN:1:±i*,iiiQ:nflar,fi. :6 . '..: ••• „.,1, :-. , ....: ••.,... ..t. ,.. , . ..t L . ...'. '6:,.: 7'.:...,". IX] 1 - and 2 dwelling 0 Commercial/industrial 0 Accessory building For special information use checklist. 0 Multi-family 0 Master builder D Other pacriptit r!l J: 0 . tiON' ;, 1,e 4".: q; ' ''' ' ' • ::;,' ''::;': lkatingic"ling Air conditioning or heat pump r• i ot Job site address: 1 13 05 5_ wc,S),nu+ c ru q uirc4 site pion showing pl I 14.00 Pl. City/Slate/41P: 4.----- , di - di 0 i Furnace 100.000 1.3T1,1 (ducts/vents) I 14,00 j (1•� Furnace 100,000 BTU (duetsh.muts) I 17.90 Suite/bldg./apt. no.: , Project name: a * PAc Gas heat pump J 14.00 Cross street/directions to job site: - u...D cLeAC:c. 1 Duct work 14.00 Hydronic hot water system 14.00 Residential boiler (radiator or 1:n4:Ironic) 14.00 t mit heaters (fuel-type, not elec(ric), • in-wall, in-duct, suspended, etc. 10.00 - Flue/vent for any of above 10.00 Subdivision: Lot nos; Other- 10.00 ____ Tax map/parcel no.; other fuel appliances ,..., , p , .: , . / -..- 7 , . .,,.> kE : ,, v Rh r, ., ,,,..... / „- . .„ -- 7 , . , ,.:.:,..:,-,...t„ Water heater 10.00 ,,: 14.,.74. ',': :':' ',WF - ,,• .'," • - . , -•,:z] ,: , (ins iircp1 ace , I _10.00 10. - 1 - e_f_ • , ._ F lue vent for walcr heater or gas fireplace 10,00 _ ... • ' 4 . 4 4 Log lighter (e.ilS) 10,00 -. Wood/pellet stove 10.00 .----..... Wood fireplace/insert 10.00 , Chimney/finer/flue/vent 10,00 V. i '.,51,,,,.-r.64".'''fli vukkife .:7 ' . . •-• - ', . ;•,; .,,!.,:. clfrIti:ARIP,`.:i..::•:. 7 s 1 : - ' ,1 ‘,Q., . ;-: .,•• s , m, -, ',.- • .. '3?ii'L' - '.' ' Other. 10.00 Name; . - Environmental exhaust and ventilation 0 . A A. - • ',..--• I • Range liond/other kitchen Address: I InS ' _ .. 4 n , 09.ipment 10.00 City/State/ZIP: . , a 0 • r 01. 7. . 1 ..3 Clothes dryer exhaust 10.00 Single-duct exhaust (bathrooms, Phoue: e3) 5-91. t ''AJ 3 I- F ax ( ) t compartments, utitity rooms) . 6 80 ri ii i .':...• 7 .: t 7"1.41;1.'"4.44i4M...i15,144.1P,,.. t:".;v?"..lifj',11.".?1‘ AifiCkraWISPaCe fans 10" Other 10.00 Business name: . Fuel piping Contact name radii,- . •• , • .1% _ -.TO_ $5.40 for first four; mop for cash Additions Furnace, etc. , _ Address: (rie; heat pomp ' City/State/ZIP: . Wall/suspended/unit heater _ Water heater Phone: ( ) Fox: : ( ) • _ Fireptace E-mail' . _ Rang! - fiarbecue 4 - 4.. \ - ,, CONTLAri OR, , . .. . ' ,. • ..- 5 ÷' Ai.:.': ,,., c loth% dryer (gas) .. Business name; Service NOW of Oregon, Inc. Other: Address: 404 S . I3eavercreek Rd # 228 :.. P ERI4t.4,' it'S ,1, Subtotal Vi, , o b cityist,Ite/Z1P: Oregon City, OR 97045 , minimum permit fee ($72. Phone: (5" --, v..) ) 655-7558 Fax: (503) 655-7593 plan review (25% et fee) ....--. _ Ceti lic.: 161584 _ state surcharge (8% of permit fee) _ TOTAL PERMIT FEE Authorized M / gt , • IP ' 0e4,fr4' ‘ , Date: 76 r b C This permit a gpiieo don v■pircs if a permit ki nOt obtained within 180 days after it 1114 been accepted as complete- ' Fee methodology eel by fn-Comiry Ditildinst Industry Service Board Print name; /g , , ri insal r ., t _ . imulleinok.p. ntEr..Pcrmlopp,doc 1 vas . 410-4617 clitovcommen) CITY _OF T!GARD BUILDING DIVISION PERMIT #: MEC2005 00165 4/11/2005 13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: Phone: (503) 639 -4171 �mrv- m i {� Inspection Requests (24 Hrs.): (503) 639 -4175 .�' 111. • INSPECTION WORKSHEET FOR DATE: 7/25/2005 TIME: 7 :12AM PAGE: 75 SITE ADDRESS: 11305 SW WALNUT ST CLASS OF WORK: SUBDIVISION: LOT #: TYPE OF USE: PROJECT NAME: HARRIS DESCRIPTION: Installation of NC, gas furnace & gas fireplace. 4/13105: Added 2nd gas furnace. 4/18/05: Adding gas piping for 2nd furnace. OWNER: HARRIS, JAMIE, - PHONE #: 503- 591 -1337 CONTRACTOR: SERVICE NOW OF OREGON INC PHONE #: 503-655-7558 Inspection Request Scheduled For: Date: '7/25/2005 Pour Time: Code # Inspection Description Confirm # Contact # Message 699 Mechanical final 012015-01 _ 503°655 58 75 Y Corrections/Comments/Instructions: - L 140‘ C` lr45P-= cTIG ^iv -rc_ 6-2 F-r r • • kii PASS ❑ PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS ❑ FAIL CALL FOR INSPECTION ❑ ADDITIONAL FEES ASSESSED Inspector: Date: 7- 2r-vr Phone #: (503) 718- •