Permit C ITY 6F TIGARD MECHANICAL PERMIT
COMMUNITY DEVELOPMENT PERMIT #: MEC2007 -00017
TI DATE ISSUED: 1/9/2007
. - . 13125 SW Hall Blvd., Tigard, OR 97223 503.639.4171 PARCEL: 2S103DC -03500
SITE ADDRESS: 11265 SW VIEWMOUNT CT ZONING: R -4.5
SUBDIVISION: VIEWMOUNT LOT: 023 JURISDICTION: TIG
Project Description: Replace furnace duct work & vent with like kind.
CLASS OF WORK: OTR FLOOR FURN: EVAP COOLERS:
TYPE OF USE: SF UNIT HEATERS: VENT FANS:
OCCUPANCY GRP: R3 VENTS W/O APPL: VENT SYSTEMS: 1
STORIES: BOILERS /COMPRESSORS HOODS:
FUEL TYPES 0 - 3 HP: DOMES. INCIN:
NAT 3 - 15 HP: COMML. INCIN:
MAX INPUT: BTU 15 - 30 HP:
FIRE DAMPERS ?: 30 - 50 HP: REPAIR UNITS:
GAS PRESSURE: 50 + HP: WOODSTOVES:
CLO DRYERS:
FURN < 100K BTU: 1 AIR HANDLING UNITS OTHER UNITS: 1
FURN > =100K BTU: <= 10000 cfm:
> 10000 cfm: GAS OUTLETS:
Owner: FEES
CURT LANGER Description Date Amount
11265 S W V I EWMO U NT CT
TIGARD, OR 97223 [MECH] Permit Fee 1/9/2007 $72.50
[TAX] 8% State Surchari 1/9/2007 $5.80
Phone: 503- 639 -8082
Total $78.30
Contractor:
ANCTIL SHEET METAL CO.
4320 N WILLIAMS AVE
PORTLAND, OR 97217 -2952 REQUIRED ITEMS AND REPORTS
Contact #: PRI 503- 281 -0752
FAX 503- 282 -5722
Reg #: LIC 8897
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Ore. Specialty Codes and all other applicable laws.
All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is
suspended for more than 180 days. ATTENTION: Oregon law requires you to follow rules adopted in the Oregon Utility Notification Center.
Those rules are set forth in OAR 952 - 001 -0010 through OAR 952- 001 -0100 You may obtain copies of these rules or direct questions to OU NC by
calling 503.246.6699 or 1.800 332.2344.
•
1
I sued By: , �� L L _ &4 Permittee Sig %' A ii /
Call 503.639.4175 by 7:00 a.m. for insp • s t : busin ' day.
This permit card shall be kept in a conspicuous place on the jo• site until completion of the project.
Approved plans are required on the job site at th- time of each inspection.
li
No.: ;a ' ;T g Wd. 17G 7 Peml t Wi �. 't c ! 7
1 123 WItal1'BIvd: 1 . F �. `�•
• g. $ •01t� ��• elan Review Other Permit
Phon :.,503 ' :63 , 441 5 ` X75 03.398.1960 ..,, � Date y:
p 4 8 200 ',. -�, ��: sa gee Page 2 far
Internet www ei tlgard or.ue No tlBed/Met hod Supplemental Information
! permit .... fees* are based on the value of the work ■
cj New :cons ion . .4 � " . ∎ � I .: f . teration/replacement performed Indicate the value (rounded to the nearest dollar) of all
• .. Q= j o �yljp • m; mechanical , .4 e • . • en labor overh 4 and • fit
•
71 1- and i-lemilydzirelling , Q. Commercial/industrial 0 Accessory building
For special h}formttacm use checklist
:18i Multi - Y. Q' • builder 0 Other: Description Qty. En. Total
gea ,
e� , Air conditloning or heat pump
'1°1141M eddtass,: I L I v' 1 J � 1/ / 1 etot.o.on - (VA/ -1' site Isa 14.00
Furnace 100 000 BTU ducts/vents [IM 14.00 lai��
k + 17.90
Suiteibldg,/r#pt,no, Project name vw()a )- Gas heat . ... 14.00
CMis street/directions to jobsite: Ductwork MB 14.00 1371M1
dronic hot water . .".. 14.00
Residential boiler (radiator or
h dronic . 14:00
- Unit heaters (fuel -type, not electric), -
. in -wall, in-du sus . .. . . etc. 10.00
Subdivision: Lot no.: Flue/vent for an of above = �
10.00 M
Other. 10.00
Tax nep/Pficel no Other fuel a fiances
Water heater 10.00
• ...,, Gas 1 dace 10.00
i 1 OJ 1 {k Cam— Flue vent for water heater or gas -
fire .lace 10 00
Lo: li ' -, 10.00
.- " Wood/. et stove 10.00
` Wood . .lace/insert 10.00
_ Chime /liner/flue/vent 10.00
pi � 10.00
Name: D -1' / ' � e-,/ n ,� e
` ! Range hood/other kitchen
Address:'. I I -( �^ ∎ 60 1l ( e roig- ( ,v+- , uj.meat 10.00
City/State/MI: r— i oj e- 3 Clothes .. r eadtaust 10.00
�
Single-duct exhaust (bathrooms,
Phone: ) (D - ' Fax ( ) toilet com . artments tail' rooms 6.80
` wls .. fans
, .•_.... , ... ,-,' '.. , ', _,_.. ,_.5
AtticJcra • l
.. . _ y 10.00
Other.
Business fume: , , t ' T rrA i i PiP,,.. 1 1n h CJt7 Ca(X ,) Fuel .1. in
( ]„
Contactnaaie: , � 1(, f
i f..0n $5.40 for first four. $1.00 for each additional
Address: L4,21?-2 I �' '11 F1m1• . etc.
- l 1 �Gl r)� s Vt°� ei1 Q� Gen heat • um • =_
City /State/.'. ,' '9 - Wallis •- .ded/unitheater iii
Phone: .(53) ?I - D Fax: : ( 1::: 3 )a zrr3•� � ..?c.?. Water heater
E—mail � G 1.. IMMININIMIIIIII
Barbecue
I ' � L : . Clothes •
na
Business me: r-,t) I i//P� C /n� Ltrn Other. ==
Address: - ' `' r
Subtotal 2i-,1).D
city /state/ZIP: , Minimum permit fee ($72.50) . J
Phone: (; ) Fax: ( )
Plan review (25% of permit fee) CCB lie.: . S l - State surcharge (8% of permit fee) ,.
TOTAL PERMIT FEE (ta DJ aa
This permit application expires If a permit Is not obtained within 180
AUfhorized signature: ��� o� r days after it has been accepted as complete.
P r i n t name: N ' 5 4 - i /) e_ 6 / rZy Date: 1 i �f �q-- a Fee methodology set by Tti-Comty Budding Industry Service Board
i1B ' doc 1203 `7 440.4617T(11/02/COM/WFe)
ZO0 /T00LJ XVd LO:9T L00Z/80/T0
CITY OF TIGARD
BUILDING DIVISION PERMIT #: MEC2007 -00017
13125 SW Hall Blvd., Tigard, OR 97223 DATE ISSUED: 119/2007
Phone: (503) 639 -4171 ICI
Inspection Requests (24 Hrs.): (503) 639 -4175 �.
INSPECTION WORKSHEET FOR DATE: 315/2407 TIME: 7:00AM PAGE: 55
G DS,
US-
SITE ADDRESS: 11265 SW VIEWMOUNT CT CLASS OF WORK:
SUBDIVISION: VIEWMOUNT LOT #: 023 TYPE OF USE:
PROJECT NAME: LANGER
DESCRIPTION: Replace furnace duct work & vent with like t nd.
OWNER: LANGER, CURT PHONE #: 503639.8057
CONTRACTOR: ANCTIL SHEET METAL CO. PHONE #: 503- 281 -0752
Inspection Request Scheduled For: Date: 3/5/2007 Pour Time:
Code # Inspection Description Confirm # Contact # Mn
699 Mechanical final 044128 -01 503-495 -5219
Corrections /Comments/ Instructions:
r (AO _s .. 7 • ` 9
o
1r, PASS X, PARTIAL APPROVAL ❑ CANCEL ❑ NO ACCESS
❑ FAIL 111 - AL FOR INSPECTION ❑ ADDITIONAL F ES ASSESSED
::2_,
Inspecto — Date: v 0 Phone #: (503) 718 -