Correspondence Ih� April 5, 2005 CITY OF TIGARD ,\ OREGON Evergreen Engineering Steve Cruft 20827 NW Cornell, # 200 Tigard, OR 97124 • RE: HVAC MODIFICATIONS — HEMCON MANUFACTURING FACILITY Project Information Building Permit: MEC2005 -00095 Construction Type: VN Tenant Name: Hemcon Occupancy Type: F2 Address: 10575 SW Cascade Ave Occupant Load: 72 Area: 19827 +1- sq. ft. Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2002 edition. The submitted plans are approved subject to the following. 1. Ductwork shall be supported in accordance with Sheet Metal & Air Conditioning Contractors National Association, Inc. (SMACNA) 2. Equipment and appliances regulated by this code requiring electrical connections shall have a positive means of disconnect in accordance with the Electrical Code. 301.7 OMSC 3. Appliances serving different areas of a building other than where they are installed shall be permanently marked in an approved manner that uniquely identifies the appliance and the area it serves. 304.10 OMSC 4. Appliances shall be accessible for inspection, service, repair or replacement without removal of permanent construction. 306.1 OMSC 5. Manufacturer's installation instructions shall be available on the jobsite at the time of inspection. 304.1 OMSC 6. Condensate from cooling coils or evaporators shall be collected and discharged to an approved plumbing fixture or disposal area. 307.1 OMSC 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 7. Smoke detectors shall be installed in return air systems with a design capacity greater than 2000 cfm. Upon activation, the smoke detector shall shut down the air ` distribution system. OMSC 606.2 9. Fire and smoke dampers shall be provided with an approved means of access, large enough to permit inspection and maintenance of the damper and its operating parts. The access shall not affect the integrity of fire - resistance -rated assemblies. The access openings shall not reduce the fire - resistance rating of the assembly. Access points shall be permanently identified on the exterior by a label having letters not less than 0.5 inch in height reading: SMOKE DAMPER or FIRE DAMPER. Access doors in ducts shall be tight fitting and suitable for the required duct construction. OMSC 607.4 11. Guards shall be provided where appliances are located within 10 feet of the roof edge or open side of a walking surface and such edge or open side is located more than 30 inches above the floor, roof or grade below. The guard shall be 42 inches above the elevated surface with an intermediate rail so as not to allow the passage of a sphere, 21 inches in diameter. 304.9 13. Steam piping is regulated according to and under the jurisdiction of the Oregon Boiler and Pressure Vessel Law and related administrative rules and the jurisdiction of Oregon Building Codes Division, Boiler and Pressure Vessel Program. Water piping for hot -water heating systems and hydronics shall be installed according to Ch. 12. OMSC 1017.1 Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Res ect lly, Val Henze , Senior Plans Examiner / /i� I hI \ April 1, 2005 CITY OF TIGARD OREGON Evergreen Engineering Steve Cruft 20827 NW Cornell, # 200 Tigard, OR 97124 RE: HVAC MODIFICATIONS — HEMCON MANUFACTURING FACILITY Project Information Building Permit: MEC2005 -00095 Construction Type: VN Tenant Name: Hemcon Occupancy Type: F2 Address: 10575 SW Cascade Ave Occupant Load: 72 Area: 19827 +1- sq. ft. Stories: 1 The plan review was performed under the State of Oregon Mechanical Specialty Code (OMSC) 2002 edition. The following information is required in order to complete the review. 1. Provide equipment specifications as required per OMSC 106. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respect y, ce/ Val Henzel, Senior Plans Examiner 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772