Correspondence t 4 t II III 61 fq90. DAVID BISSETT & ASSOCIATES - 7 i 0 3 V ARCHITECTURE • PLANNING • INTERIORS MEMORANDUM November 10, 1999 RECEIVED To: Robert Poskin CBO City of Tigard NOV 1 i 1999 From: David Bissott.AlA Project Architect COMMUNITY DEVELOPMENT Re: VARNS STREET BUILDING BUP # 99 -00465 Thank you for the prompt issuance of the plan review checklist. We have corrected and clarified the permit documents as follows: 1�1 /11a ACC SIBILITY a o , . The accessible aisle and signage for parking has been corrected and shown on the site plan as nested and required ( see attached drawing revisions ). t9e/ . The 1�` and 2 floor rear exits have been connected to an accessible route via a new concrete walk to the existing public sidewalk as requested and required. 0 1 , . The existing landing at stair #2 and clearances at door 102 have been clarified to compliance as required and requested. 0 . required. / Handrails on both sides of each stair have been noted as requested and require ©'/ �• The existing unisex accessible restroom has been noted as requested and required. V / • Door #204 has been deleted from Hall 219 to meet required clearances. ��� FIRE .D LIFE SAFETY 0 I� . E xit stair #2 existing landing has been noted to clarify location as requested ( see also item 3 above). 191 Exit stair #2 existing door location and clearances has been noted to clarify compliance as requested and required ( see also item 3 above ). EXIT GHTING 1 Egress / Exit identification signage has been added to the foyer adjacent to the first floor shared office as ed and required. 1B,C, E. Directional exit arrow added to door 103, exit sign added at reception area, directional arrow added near door 202 and exit sign exists at stair # 2 as requested and required. 322 NW 5th Avenue • Portland, Oregon 97209 • (503) 226 -6785 • FAX (503) 224 -2311 STRUCTURAL 1. Seismic detail for full height non - bearing walls provided as requested and required. 2. The existing suspended acoustic ceiling system will remain in place. Per our phone conversation, bracing of the existing ceiling grid frame will not be required as long as we are only replacing existing acoustic.tiles (,no limit on how much is retained or replaced ). Therefore the requirements as set forth in item 2 of your checklist will not be required. The plans are noted to indicate that the existing ceiling grid is to remain. Attached are 81/2 x 11 copies of the submittal revisions as noted herein for your review and approval. We would like to attach these to the original permit documents to complete the permit process and will be glad to submit full size drawings when approved for issuance. Please call me directly if you have any questions or concerns. Your help in completing the plans review by Tuesday 11 -16 -99 will be greatly appreciated as there is a very tight time frame for the tenants move -in schedule. Re / - u y Sub . 'fled, �avid sett /AIA/ �� .. cc: project file 0 = " Gb�i1411 ro1(i�� November 3, 1999 1 "1I iik CITY OF T1GM1 David Bissett, AIA OREGON 322 NW 5th Ave #301 Portland, OR 97209 RE: Varns Street Building Building Plan Review - 7105 SW Varns Road PC #: 10-61c BU P #: 99 -00465 Submittal documents for the above referenced project have been reviewed for conformance with the applicable 1998 Oregon Specialty Codes and other applicable codes and standards. The following comments are noted: I ACCESSIBILITY 1 Under the provisions of OSSC, Section 1113 and ORS 447.241, the 25% rule in choosing accessible elements requires parking as the first element of compliance. Your vicinity site plan indicates the absence of an accessible aisle and no mention of required signage. Provide details. OSSC, Section 1113 and OSSC, Section 1104. . The rear exits from both the 1 and 2 floor must connect to the accessible route. Provide details. OSSC, Section 1104.4.5. The landing requirement at Stair #2 as well as the door at 102 come under the provisions of OSSC, Section 1113, Item (c). See Fire Life Safety requirement. . Handrails will be required on both sides of both stairwells complying with OSSC, Section 1109.8.6. Provide details. OSSC, Section 1113.1.2.1. . Provide one (1) unisex accessible bathroom. OSSC, Section 1113(d). Door #204 entering Hall 219 shall have 18 inches of clearance on the latch side. Provide details. OSSC, ADAAG Figure 25(a). I FIRE AND LIFE SAFETY 1. Exit stair #2 — Question is where is the landing? 2. Exit Stair #2 — The position of the doors at the bottom obstruct the required landing at doors. Provide details. OSSC, Section 1003.3.1.7 and OSSC, Section 1113. I EXIT LIGHTING I 1. Path of travel egress and exit identification signage shall be required as follows: A. In the foyer adjacent to shared office space on the 1 floor. 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Varns Street Building Building Plan Review PC #: 10-61c BUP #: 99 -00465 Page #2 B. A directional exit arrow at Door 103, 1 floor. C. An exit sign at the opening to the receptionist area on the 2 floor. D. A directional arrow near Door 202 at Large Office #2, 2 floor. E. An exit sign at Stair #2, 2 floor. Provide detail OSSC, Section 1003.2.8. (STRUCTURAL 1. Provide a seismic detail on how you will support your full height non - bearing walls. OSSC, Section 1626.2. 2. Suspended acoustical ceiling systems shall comply with the following: A. Be anchored to resist lateral seismic forces [OSSC, Section 1632 and Table 16 -0]. Provide suspension wires not smaller than No. 12 gauge spaced at 4" 0 /C, perimeter wires on terminal ends of cross and main runners at a maximum of 8" from each wall, four No. 12 gauge wires splayed 90 degrees from each other at an angle not exceeding 45 degrees from the plane of the ceiling with a strut centered and extending to the structural members supporting the floor or roof above and spaced 12" on center in both directions starting 6' from each wall, and B. All lighting fixtures weighing less than 56 lbs, shall be positively attached to the suspended ceiling system [UBC Std., Section 25.213], and C. #12 gauge wires shall be attached to the grid members within 3" of each corner of the fixtures, and D. Lighting fixtures shall have two No. 12 slack wires connected from the fixture to the structure above, and E. Ceiling- mounted air terminals or services weighing less than 20 lbs. shall be positively attached to ceiling runners. i. Provide details in the revised plans. F. T -Bar ceilings shall not be used to support partition walls. Please submit two copies of revised submittal documents and a letter indicating your response to the above comments for review. Please call me at (503) 639 -4171 if you have any questions. Sincerely, Ro ert Poskin, CBO SENIOR PLANS EXAMINER I thldglprmsystbup99465 doc