Loading...
Permit CITY OF TI GA R D ELECTRICAL PERMIT 4,04 A, DEVELOPMENT SERVICES PERMIT #: ELC98 -0637 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 - 4171 DATE ISSUED: 10/21/98 PARCEL: 15125DD -00000 SITE ADDRESS...:06745 SW VENTURA DR SUBDIVISION •USA PEDESTAL ON VENTURA DR ZONING:R -7 BLOCK LOT . JURISDICTION: Project Description : One 200 co service /feeder and one branch circuit. - -- RESIDENTIAL UNIT - - -- -- -TEMP SRVC /FEEDERS - - -- MISCELLANEOUS 1000 SF OR LESS • 0 0 — 200 amp 0 PUMP /IRRIGATION • 0 EACH ADD'L 500SF...: 0 201 — 400 amp 0 SIGN /OUT LINE LTG..: 0 LIMITED ENERGY 0 401 — 600 amp • 0 SIGNAL /PANEL •'0 MANF. HM/ SVC /FDR..: 0 601 +amps -1000 volts.: 0 MINOR LABEL (10)...: 0 - - -- SERVICE /FEEDER - - -- - - -- BRANCH CIRCUITS -- -ADD'L INSPECTIONS-- - 0 — 200 amp ° 1 W /SERVICE OR FEEDER: 1 PER INSPECTION ° 0 201 — 400 amp 0 1st W/0 SRVC OR FDR.: 0 PER HOUR • 0 401 — 600 amp : 0 EA ADD'L BRNCH CIRC: 0 ' IN PLANT • 0 601 — 1000 amp • 0 PLAN REVIEW SECTION 1000+ amp /volt ° 0 > =4 RES UNITS • ) 600 VOLT NOMINAL..: Reconnect only • 0 SVC /FDR )= 225 AMPS..: CLASS AREA /SPEC OCC.: Owner: FEES OREGON ELECTRIC GROUP type amount by date recpt 1010 SE 11TH PRMT $ 65.00 GEO 10 /21/98 98- 310189 PORTLAND OR 97214 SPCT $ 3.25 GEO 10/21/98 98- 310189 Phone #: Contractor: OREGON ELECTRIC CONST /GROUP $ 68.25 TOTAL 1010 SE 11TH AVE REQUIRED INSPECTIONS PORTLAND OR 97214 Elect'1 Service Phone #: 234 -9900 Elect'1 Final Reg #..: 203 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of Oregon Specialty Codes and all other applicable laws. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952- 001-0010 through OAR 952- 001 -1987. You may obtain a copy of these rules or direct questions to OUNC by calling (503)248 -1987. �/ Permittee Signature: /l.�i9� Issued By: �� OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale, lease, or rent. OWNER'S SIGNATURE: DATE: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR. ELEC' N : CAP DATE: /D - /? /-'`z 1/ ++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ±+ Call 639 -4175 by 7:00 p.m. for an inspection needed the next business day ++++++++++++++++++++++++++++++++++++++++++++++++ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + ++ 1 (y9J ' tY P Commun Development ELECTRICAL PERMIT APPLICATION 13125 SW Hall Blvd. Tigard, OR 97223 RE C E1lVEL Planck/Rec. # Issued by � � " iu� I,. GAT Permit # b' ' 9 _C3 ,� �l Phone (503) 639 -4171 2 Date Issued ` FAX (503) 684- 7n7iimr 799L pate OF TIGARD TDD No. (503) 684 - 2`!72 /TY DEV E l OPP2E] IsIs Inspection (503) 639 -4175 1. Job JOB NO.114 1 4. Complete Fee Schedule Below: Name of Development Unified Sewerage Agency Number of Inspections per permit allowed Addresssee map Service included. Items Cost(ea) Sum City/State/Zip Tigard, Or_ 4a. Residential I -per unit 1000 t $110.00 Name or name of business) Unified Sewerage Each add soo s q tt. cr 1 ( ) 9 a portion thereof $25 00 Commerciab x Residential ❑ Limited Energy $2500 x c Each Manul Home or Modular 2 Dwelling Service or Feeder $68 00 2a. Contractor installation only: 4b. Services or Feeders Installation, alteration, or relocation 2 Electrical Contractor Oregon Electric roup 200 amps or less 1 $60.00 60.00 2 201 amps to 400 amps $80 00 2 Address 1 n 1 n SF. 1 1 1-h 401 amps to 600 amps $120 00 2 City Pnr1-1 and, State o Zip9721 4 601 amps to 1000 amps $18000 2 Phone No. a 31 9 9 013 amps or volts $340 2 - 50 0 Contractor's License No. 26-95C Reconned only Contractors Board Reg. No. 2 4c. Temporary Services or Feeders Installation, alteration, or relocation 2 Signature of Supr. Elec'n v+����# 200 amps or less $50 00 2 License No Phone No. 2 3 4 - 9'9 0 0 201 amps to aoo amps $75 00 2 a 41 L d 401 amps to 600 amps $100 00 Over 600 amps to 1000 volts 2b. For owner installations: see 'b' above Print 4d. Branch Circuits rint Owner's Name New, alteration or extension per panel Address a) The lee for branch circuits with purchase of service or feeder fee. 2 City State Zip Each branch circuit $5 00 S 0 0 Phone No. b) The fee for branch circuits without The installation is being made on property I own which is purchase of service or feeder fee. 2 not intended for sale, lease or rent. First branch circuit $35 00 2 Each additional branch circuit $5 00 Owner's Signature 4e. Miscellaneous (Service or feeder not included) 2 3. Plan Review section (if required): Each pump or irrigation arde $40.00 2 - Each sign or outline lighting $40 00 Signal cucwt(s) or a limited energy 2 Please check appropriate item and enter fee in section 5B. panel, alteration or extension $40 00 4 or more residential units in one structure Minor Labels (10) $10000 Service and feeder 225 amps or more System over 600 volts nominal 4f. Each additional inspection over Classified area or structure containing special occupancy the allowable in any of the above as described in N.E.C. Chapter 5 Per inspection $35 00 - Per hour $55 00 - In Plant $55 00 Submit 2 sets of plans with application where any of the above apply. Not required for temporary construction services. 5. Fees: NOTICE 5a. Enter total of above fees $ 6 5 . 0 0 5% Surcharge (.05 X total fees) $ 'I 7 S PERMITS BECOME VOID IF WORK OR CONSTRUCTION Subtotal $ 61:1 5 AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF Sb. Enter 25% of line A for CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR Plan Review if required (Sec.3) $ A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS Subtotal $ COMMENCED. ❑ Trust Account # $ w c c,, alance Due $ 6 8 - 2 5 wadtomdWmiscrrm,epp CITY OF TIGARD BUILDING INSPECTION DIVISION MST 24 -Hour Inspection Line: 639 -4175 Business Line: 639 -4171 BUP 5 /55.35 Date Requested /o71 / " 9S ,A�M/� PM BLD Location 6 7 7 S , Y,0 21 L4 6 - Suite MEC Contact Person ! . ,A_./ 4 , ! a 555: 2655 PLM Contractor O - C- t i✓T / t�'-f Ph SWR �1 BUILDING Tenant/Owner 4 7t( 7 Retaining Wall ELR Footing Access: Foundation FPS Ftg Drain SGN Crawl Drain Inspection Notes: Slab SIT Post & Beam Ext Sheath /Shear Int Sheath /Shear Framing Insulation Drywall Nailing = _ 1«-2_ _ - Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling C—�.4 - --0 Roof Misc: Final PASS PART FAIL PLUMBING e Post & Beam Under Slab Top Out Water Service • Sanitary Sewer Rain Drains Final _ PASS PART FAIL MECHANICAL Post & Beam Rough In Gas Line Smoke Dampers Final RL FAIL CTRICAL5 Service Rough In UG /Slab Low Voltage rm Fin -PART FAIL S Backfill /Grading Sanitary Sewer Storm Drain [ ] Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd Catch Basin Fire Supply Line [ ] Please call for reinspection RE: [ ] Unable to inspect - no access ADA - Approach /Sidewalk Date �/ Inspector Other nspecor Ext x Final PASS PART FAIL DO NOT REMOVE this inspection record from the job site. • SCHEMATIC / CITY /COUNTY: CITY OF TIGARD � i'""'+ (- y 1997 THOMAS GUIDE PAGE: 655 H1 LOCATION: 6755 SW VENTURA PL 1 r ACCESS: / / � S .7, 4- s - f PULL MIES Lk duvc• BOX 4125F211 r;►, BOX p/ /' . 1 1 r 11E1 I ```'. , , W E USA I I - a• I CONDUIT FROM EXISTING LIGHT PED. TO MH. MANHOLE POLE LIN PU I I DEPTH 25' BOX 1 S1W25D0 I 2 S` I a• CASING L V I o 03500 5 C SANITARY SEVER LIN f co l + � 6720 SW 1 L. • I 20' i• -<• VENTURA DR CLASS E , w �I z o L • / M I C 0 ti.. _, I -I '7 ISIV25DD 1S1W25DD L /►� A ‘\ 1S1W25DD 05900 f 05700 ISIV25DD 03600 I I IS1V25DD 05800 9885 SW ! c o I ` _ r 05600 5059 VENTURA CT I • D4' 5069 1111110 .. I" � - LEGEND D7' 5068 D7 ;. .- S ISIV25D S EWER LINE 03300 I .. LOT LINE IIII A ISIV i DIAMETER SLOPE LENGTH SW VENTU ACT. 03400 ` ..-- 24' 0.004 33 SW 1503600 n I a 0 EXISTING POWER POLE it Ism + r - 26 UNDERGROUND UTILITIES P.1234 SCALE1 ISIV25DD • �' 10 - 6' V WATER NEV NEV EN �Sp il �� -�.• c+ • , 1 i G GAS 1' = 100' 03700 ✓ i - � r ' v\ I / i CC CABLE TV POWER POLE V/ G P VIIRE - S oaS �' , �� 2`� A — C O PROPOSED ` ELECTRIC H � -GTE TELEPHONE ISIV25DD i I � D DD iSIV25DD 1 2 �j PED ESTAL �= STERN NEW EXISTING • 03800 / • i r ls1v 7‘ 00900 01000 I Y MH 5048 ¢ MANHOLE MANHOLE 1S1v25D I / D25 SCALE: ABBREVIATION • O -- .1, 00800 / 0 I' = 20' A.C ASPHALTIC CEMENT i = NEV UTILITY NEW SENSOR .c - .- • .... / , 117 Y� R/V RIGHT CF WAY VAULT OR INSIDE SEVER R --- wl STORM 1 Iz 3 PVC POLYVINYL CHLORIDE PEDESTAL PIPE 5050 ISIV25DD ..-- 1111 E 6 LP. LIGHT POLE D7' 02900 5047 / _ . m 1S1W25DD S1 W25DD N'♦ MANHOL De' �• ' 11 0 0800 PS PUM STATION NEW UNDERGROUND IS1V25DD i ISIV25DD W CONDUIT 6755 $W Vv VE YELL 02800 03000 > VENTURA • FM FORCE MAIN • v v Y I g � +. ' . 1SIV25DD 1S1V25DD 1S1v25DD 01800 01700 01600 D7' DEPTH 7 EASEMENT EEP EDGE OF PAVEMENT • _ -_ _._ - - - VICINITY MAP SITE MAP .SIGN: SL REVISIONS: SHEET: 3 SANITARY Q DRAWN: NL f unified �` ` IT R 1 SEWER MANHOLE NO. 5048 CHECKED: SL — - agency PERMANENT FLOW MONITOR SITE D022 'ROJECT NO. 4125 APPROVED: TC DATE:MARCH 1998 LATOUREN H• \MY DOCUMENTS \ORAWFILE\MONSITE \BROSO48 DWG