Loading...
Permit a CITY OF TIGARD MASTER PERMIT ; �"! s, COMMUNITY DEVELOPMENT Permit #: MST2012 00256 TIGARD 13125 SW Hall Blvd., Tigard OR 97223 503.718.2439 Date Issued: 10/02/2012 Parcel: 2S101AB00101 Jurisdiction: Tigard Site address: 12120 SW 72ND AVE Subdivision: 1996 - 024 PARTITION PLAT Lot: 2 Project: Tri- county Center Trust Project Description: Demolition of 2,534 sq ft house and attached garage. Property is on septic. Future SDC credits available once final inspection complete. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $8,000.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains. 0 Tubs /Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell- Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn <100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Fum > =100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc /Feeders Branch Circuits 1000 sf or less: 0 0 -200 amp: 0 0 -200 amp: 0 W/ Svc or Fdr: 0 Ea add'l 500 sf: 0 201 -400 amp: 0 201 -400 amp: 0 W/O Svc /Fdr: 0 Mfd Home /Feeder /Svc: 0 401 -600 amp: 0 401 -600 amp: 0 601 -1000 amp: 0 601 +amp- 1000v: 0 1000 +amp /volt: 0 ELECTRICAL - RESTRICTED ENERGY SF Residential Audio & Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: FND SF 0 Owner: Contractor: TRI- COUNTY CENTER TRUST MOUNTAIN VIEW TREE SERVICE Required Items and Reports (Conditions) MARTIN, GORDON R TR PO BOX 80805 BY ADAMS & STEWART PORTLAND, OR 97280 8565 SW BARBUR BLVD PORTLAND, OR 97219 PHONE: 503 - 245 -9235 PHONE: 503 - 830 -1468 FAX: Total Fees: $270.38 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done ' • - • • - ce with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ' TTENTION: • = ■on law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 95 001 -0010 through OAR • •2 -0t 90. ou may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 00.332.2344. Is ued By: _ Permittee Signature: cC/� Call 503.639.4175 by 7:00 a.m. for the next available inspecti n date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Residential FOR OFFICE USE ONLY RECEIVED 14 +�wVElD Received � 0��� I /I� rr - City of Tigard +� Deters : _ Permit No.: /A 13125 SW Hall Blvd., Tigard, OR 97223 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 ; , ; 0 2 qq 2012 Date/B : Other Permit: T 1 GAR D Inspection Line: 503.639.4175 Date Ready/By: June: El See Page 2 for Internet: www.tigard - or.gov ��jj CITYOFTIGARD Notified /Method: Supplemental Information TYPE OF WdllirD NG DIVISION REQUIRED DATA: 1- AND 2- FAMILY DWELLING ❑ New construction ® Demolition Permit fees* are based on the value of the work performed. Indicate the value (rounded to the nearest dollar) of all ❑ Addition/alteration/replacement ❑ Other: equipment, materials, labor, overhead, and the profit for the CATEGORY OF CONSTRUCTION work indicated on this application. ® I- and 2- family dwelling ❑ Commercial/industrial Valuation: $ j>Q a El Accessory building 11 Multi-family Number of bedrooms: ❑ Master builder ❑ Other: Number of bathrooms: JOB SITE INFORMATION AND LOCATION Total number of floors: Job site address: 12120 sw 72 ave New dwelling area: square feet City/State /ZIP: Tigard, Oregon 97223 Garage /carport area: square feet Suite/bldg. /apt. no.: I Project name: Campbell house Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet REQUIRED DATA: COMMERCIAL -USE CHECKLIST Subdivision: I Lot no.: Permit fees* are based on the value of the work performed. Tax map /parcel no.: 2s101ab00101 Indicate the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead, and the profit for the DESCRIPTION OF WORK work indicated on this application. House demolition and removal. o-n i.£P — i a Valuation: $ Existing building area: square feet New building area: square feet ® PROPERTY OWNER ❑ TENANT Number of stories: Name: Tri- County Center Trust Type of construction: Address: 8565 sw Barbur Blvd. Occupancy groups: City/State /ZIP: Portland, Oregon 97219 Existing: Phone: (503)245 -9235 Fax: ( ) New: ® APPLICANT ® CONTACT PERSON BUILDING PERMIT FEES* (Please refer to fee schedule) Business name: Structural plan review fee (or deposit): Contact name: Steve Martin FLS plan review fee (if applicable): Address: 12265 sw 72" ave Total fees due upon application: City/State/ZIP: Tigard, Oregon 97223 1 g Phone: (503) 620-0184 I Fax: : ( ) Amount received:O �Q• 3 E -mail: sb.martin@frontier.com PHOTOVOLTAIC SOLAR PANEL SYSTEM FEES* Commercial and residential prescriptive installation of CONTRACTOR roof -top mounted Photo Voltaic Solar Panel System. Business name: Mountain Vier Tree Service Submit two '. sets of roof plan with connection ietails and fire departm • access, along with the : I Oregon Address: PO Box 80805 Solar Installation S• : Laity Code eh" st. City /State /ZIP: Portland, Oregon 97280 Permit Fee (incl • "s pi: tew $180.00 and admini - . • • ve fees): Phone: (503) 830 -1468 Fax: ( ) State surcharge ( o of . " • 't fee): $21.60 CCB lie.: 179875 Wit$ / /�f � To . "- - due upon applicah . 4: $201.60 Authorized signature: i N- )- f T his permit application expires if a permit is not obtained x /y`—... / v,, <- � ,.s. --. within 180 days after it has been accepted as complete. * Fee methodology set by Tri-County Building Industry Print name: Steve Martin I Date: /0/.2,`41, Service Board. I: \ Building \Permits\BUP- RESPemtitApp.doc 02/ 24/2011 440- 4613T(11 /02/COM/WEB) .1 Building Permit Application Checklist One- and Two - Family Dwelling FOR OFFICE USE ONLY Received - City of Tigard Date/By: No.: 11 v 13 125 S W Hall Blvd., Tigard, OR 97223 Associated permits: Phone: 503.718.2439 Fax: 503.598.1960 TIGAItD 24- Hour Inspection Line: 503.639.4175 ❑ Electrical ❑Plumbing ❑Mechanical Internet: www.tigard - or.gov ❑ Other. THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ ❑ 2 Zoning. Flood plain, solar balance points, seismic soils designation, historic district, etc. ❑ ❑ ❑ 3 Verification of approved plat/lot. ❑ ❑ El 4 Fire district approval required. Name of district: ❑ ❑ ❑ 5 Septic system permit or authorization for remodel. Existing system capacity El ❑ ❑ 6 Sewer permit. ❑ ❑ ❑ 7 Water district approval. ❑ ❑ ❑ 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ ❑ 9 Erosion control El plan ❑ permit required. Include drainage -way protection, silt fence design and location of catch- ❑ ❑ ❑ basin protection, etc. 10 3 Complete sets of legible plans. Must be drawn to scale, showing conformance to applicable local and state ❑ ❑ ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full -size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site /plot plan drawn to scale. The plan must show lot and building setback dimensions; property corner elevations (if El El El there is more than a 4 -ft. elevation differential, plan must show contour lines at 2 -ft. intervals); location of easements and driveway; footprint of structure (including decks); location of wells /septic systems; utility locations; direction indicator; lot area; building coverage area; percentage of coverage; impervious area; existing structures on site; and surface drainage. 12 Foundation plan. Show dimensions, anchor bolts, any hold -downs and reinforcing pads, connection details, vent size ❑ ❑ ❑ and location. 13 Floor plans. Show all dimensions, room identification, window size, location of smoke detectors, water heater, ❑ ❑ ❑ furnace, ventilation fans, plumbing fixtures, balconies and decks 30 inches above grade, etc. 14 Cross section(s) and details. Show all framing- member sizes and spacing such as floor beams, headers, joists, sub- ❑ ❑ ❑ floor, wall construction, roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing, roofing, roof slope, ceiling height, siding material, footings and foundation, stairs, fireplace construction, thermal insulation, etc. 5 Elevation views. Provide elevations for new construction; minimum of two elevations for additions and remodels. ❑ ❑ El Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full -size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing (prescriptive path) and /or lateral analysis plans. Must indicate details and locations; for non- ❑ ❑ ❑ prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor /roof framing. Provide plans for all tloors /roof assemblies, indicating member sizing, spacing, and bearing ❑ ❑ ❑ locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ❑ ❑ ❑ systems, see item 22, "Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ El ❑ over 10 feet long and /or any beam/joist carrying a non - uniform load. 20 Manufactured floor /roof truss design details. ❑ ❑ ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas- piping schematic is required ❑ ❑ ❑ for four or more appliances. 22 Engineer's calculations. When required or provided, (i.e., shear wall, roof truss) shall be stamped by an engineer or El ❑ ❑ architect licensed in Ore:on and shall be shown to be a' ilicable to the .ro'ect under review. JURISDICTIONAL SPECIFICS 23 Three (3) site plans are required for Item 11 above. Site plans must be 8 -1/2" x 11" or 11" x 17 ". ❑ ❑ ❑ 24 Two (2) sets each are required for Items 16, 19, 20 and 22 above. ❑ ❑ ❑ 25 Building plans shall not contain red lines or tape -ons. "Mirrored" building plans will not be accepted. ❑ ❑ ❑ 26 "Reversed" building plans must meet criteria outlined in the Permit & System Development Fees document. El ❑ El 27 "Drawn to scale" indicates standard architect or engineer scale. ❑ ❑ ❑ 28 Site plan to include tree size, type and location per approved project street tree plan (if applicable), and City of Tigard ❑ ❑ ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations, driplines, ❑ ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services' Sensitive Area Pre - Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ including decks, patio covers (over non - impervious surface) and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. I:\ Building \Permits \BUP- RESPermitApp.doc 02/24/2011 440 -4613T(I I /02 /COM/WEB) . 7 , / , N .,,, i ,, ,,,, r% f 1 4' 5 4 t .., , z. ) y los ( „." ( ( ....---1 0 1 \ - / I 1 1. I / /- \jr -t ,--s _._. , \, -,-‘ .,, ..., ..-----4."-- / / / AIM= :.411C"Wimmerr MINIM( -----...■-- ,,_ _ + --‘-‘ \--- - 7 7 rP 11.-.-- - 2S101A:01111 _,F1 .55 acres ..,-- ..." -0.. i ---1 .---I 7/ -- Z ILI —,....../ Op .," 4 / ...._.. r"--.\-240—"-------- 41.4; COP1P ___I - - — CI 1 „__,-------■ Z i (- --- r tNi r ... rill , - / 1 N i ) .' -,„:, ---_, I i / 12120 1 71 . ft. - II 0 4, 2 " Tl ---- it4 2----.-- _,..., ii/ 2,534 building sq - _- - ,\ --------em - 252 :--- Conditionally Approved......... [ \ --- r ,-. ..--- See Letter to: Follow.......... ........ i J - ----- .----- / .7 -- / ,--- - ./ _."---- - Attached , i I Penult Number: -----"--- 1 1 " ,,I, ‘,/ 246 -- AO LA-/-4242- 76 ' ?lat.:. ----"•, \' :/- ----"-,., __-------) BA1.14_442,t Date: / t ''N U -- 11 ---- ,,./r. /<:1 ----------------------..._ ( ..--- / If ' , ... . , \ ---. c-- fTh / /, i ) I ') C Feet 1( ----/ Ir. 7,/ 63 0 / . .0 3 1-,-------' .1 t -• 7 1 . I . - --- Location: Record Type: Inspection Type: Comments: Inspection Date: Record ID: Result: City of Tigard 13125 SW Hal Blvd. Tigard, OR 97223 Tel: 503.718.2439 12120 SW 72ND AVE, TIGARD, OR, 97223 Residential - Master Permit 299 Final inspection 03/19/2013 00:00 MST2012-00256 FAIL Canceled Violation Summary: Inspector Contractor