Loading...
Permit '-. it CITY OF TIGA►RD BUILDING PERMIT PERMIT #: BUP2003 -00634 �i�i_ DEVELOPMENT SERVICES DATE ISSUED: 10/28/03 '` �`"' 13125 SW Hall Blvd.. Tigard, OR 97223 (503) 639 -4171 SITE ADDRESS: 09865 SW VENTURA CT PARCEL: 1 S125DD 03800 SUBDIVISION: WASHINGTON SQUARE ESTATES NO.2 ZONING: R -4.5 BLOCK: LOT: 046 JURISDICTION: TIG REISSUE: FLOOR AREAS EXTERIOR WALL CONSTRUCTION CLASS OF WORK: OTR FIRST: sf N: S: E: W: TYPE OF USE: SF SECOND: sf PROJECT OPENINGS? TYPE OF CONST: : sf N: S: E: W: OCCUPANCY GRP: TOTAL AREA: 0 sf ROOF CONST: FIRE RET? OCCUPANCY LOAD: BASEMENT: sf AREA SEP. RATED: STOR: HT: ft GARAGE: sf OCCU SEP. RATED: BSMT ?: MEZZ ?: REQD SETBACKS REQUIRED FLOOR LOAD: psf LEFT: ft RGHT: ft FIR SPKL: SMOK DET: DWELLING UNITS: FRNT: ft REAR: ft FIR ALRM : HNDICP ACC: BEDRMS: BATHS: IMP SURFACE: PRO CORR: PARKING: '''' VALUE: $ 13,000.00 Remarks: Installation of 950 square foot deck. Owner: Contractor: KOSTUR, CHARLES J + DIANNE M DECKING NW 9865 SW VENTURA CT 5775 WILLOW LANE TIGARD, OR 97223 . LAKE OSWEGO, OR 97035 Phone: Phone: 503 - 697 -9288 Reg #: LIC 44911 FEES REQUIRED INSPECTIONS Description Date Amount Footing Insp [BUILD] Permit Fee 10/28/03 $168.10 Framing Insp [TAX] 8% State Surchari 10/28/03 $13.45 Final Inspection [BUPPLN] Pln Rv 10/28/03 $109.27 Total $290.82 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more than 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952 - 001 -0010 through OAR 952 - 001 -0100. You may obtain a copy of these rules or direct questions to OUNC by calling (503) 246 -6699 or 1- 800 - 332 -2344. Issued By: _ , �,, l r.0 (' /.1/t) Permittee :/(7/A,,it. Sign ature: _< fr 6..--- all 639 -4175 by 7 p.m. for an inspection the next business day Building A 1 l Tv " "1;'JJ 04- �I t1 FOR OFFICE USE ONLY b y Received r y� Building Date/B - i X° Permit No .,„.. .,„.. f ----. 0 t i 2 t ' Planning App .val Other City of Tigard s, p 4 Date/B - Permit No 13125 SW Hall Blvd. TI G D Plan Review Other Tigard, Oregon 97223 T Date /B Permit No • r 0 • C d� , i d Phone: 503- 639 -4171 Fax: 503 - :' , 'i.i I G ( E ' Vilil Post - Review Land Use l lw I Date/B Case No Internet: www.ci.tigard.or.us Contact Juris. ® See Page 2 for 24 -hour Inspection Request: 503-639-4175 Name /Method: Su . , Iemental Information 4 7 4 /%t-e �,/ / 4c —"e7 ..-(4 d ae4 ec f� a e /..e � .C_ 7 � ./ E-df t rP E OF WORK REQUIRED DATA: J ❑ New construction ❑ Demolition 1 & 2 FAMILY DWELLING ❑ Addition/alteration/replacement El Other: CATEGORY OF CONSTRUCTION Note Permit fees• are based on the total value of the work performed. Indicate ❑ 1 & 2- Family dwelling ❑ Commercial/Industrial the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead and profit for the work indicated on this application. ❑ Accessory Building ❑ Multi- Family ❑ Master Builder ❑ Other: Valuation . $ JOB SITE INFORMATION and LOCATION No of bedrooms No. of baths: Job site address: q[j6 S 4i) (/e, "! � ri , `c G -� Total number of floors New dwelling area (sq. ft.). Suite #: Bldg. /Apt. #: Garage /carport area (sq. ft.) Project Name: k v S f-L P - Covered porch area (sq. ft.) Cross street/Directions to job site: Deck area (sq ft ). ..... ... 9 50 Other structure area (sq. ft.) REQUIRED DATA: COMMERCIAL - USE CHECKLIST Subdivision: Lot #: Tax map /parcel #: Note Permit fees* are based on the total value of the work performed. Indicate DESCRIPTION OF WORK the value (rounded to the nearest dollar) of all equipment, materials, labor, overhead and profit for the work indicated on this application. f -Lve- -./e . - �r ?(Ci c - C gr- 71/ 7>=r Valuation. $ Existing building area (sq. ft.) New building area (sq. ft.) Number of stones ❑ PROPERTY OWNER • I 0 TENANT Type of construction Name: k 05 - t - c.. re..— Occupancy group(s) Existing: New: Address: 1 8 G S 5 et> Ut,-i. b •-,: C f City /State /Zip: .--7- / .) -.�.- Phone: Z'Z – (2 it g Fax: NOTICE: All contractors and subcontractors are required to be ❑ APPLICANT ❑CONTACT PERSON licensed with the Oregon Construction Contractors Board under provisions of ORS 701 and may be required to be licensed in the Business Name: jurisdiction where work is being performed. If the applicant is exempt Contact Name: ' �G, c C � ,..--� from licensing, the following reason applies: Address: City /State /Zip: Phone: Fax: E -mail: BUILDING PERMIT FEES* CONTRACTOR Please refer to fee schedule. Business Name: D,- lc; , A/ (,(J • Fees due upon application $ Address: . 7 S w, :1 / N City /State /Zip: t g w_ .e 05"—t O Amount received .... $ Phone: 1i3 —, y'7—f Z b-Y Fax: Date received: CCB Lic. #: 4!c/ 5 < / Authorized // Notice: This permit application expires if a permit is not obtained within Signature: � 4- 5 °�---- Date: (U /�S/ 180 days after it has been accepted as complete. 7 ,9 C V,��E� *Fee methodology set by Tri- County Building Industry Service Board. (Please print name) i. \Dsts \Permit Forms \BldgPermitApp doc 01/03 Alb One- and Two - Family Dwelling Building Permit Application Checklist Reference no.• CiryofTigard C>< of Tigard Associated permits `J g ❑ Electrical ❑ Plumbing O Mechanical Address: 13125 SW Hall Blvd, Tigard, OR 97223 O Other Phone: (503) 639 -4171 Fax: (503) 598 -1960 THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No ' N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. 2 Zoning. Flood plain, solar balance points, seismic soils designation, histonc district, etc. 3 Verification of approved plat/lot. 4 Fire district approval required. 5 Septic system permit or authorization for remodel. Existing system capacity 6 Sewer permit. 7 Water district approval. 8 Soils report. Must carry onginal applicable stamp and signature on file or with application. 9 Erosion control ❑ plan O permit required. Include drainage -way protection, silt fence design and location of catch -basin protection, etc. 10 3 Complete sets of legible plans. Must be drawn to scale, showing conformance to applicable local and state building codes. Lateral design details and connections must be incorporated into the plans or on a separate full -size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions; property corner elevations (if there is more than a 4-ft. elevation differential, plan must show contour lines at 2 -ft. intervals); location of easements and driveway; footprint of structure (including decks); location of wells/septic systems; utility locations; direction Indicator; lot area; building coverage area; percentage of coverage; impervious area; existing structures on site; and surface drainage. 12 Foundation plan. Show dimensions, anchor bolts, any hold -downs and reinforcing pads, connection details, vent size and location. 13 Floor plans. Show all dimensions, room identification, window size, location of smoke detectors, water heater, furnace, ventilation fans, plumbing fixtures, balconies and decks 30 inches above grade, etc. 14 Cross section(s) and details. Show all framing- member sizes and spacing such as floor beams, headers, joists, sub-floor, wall construction, roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing, roofing, roof slope, ceiling height, siding material, footings and foundation, stairs, fireplace construction, thermal insulation, etc. 15 Elevation views. Provide elevations for new construction; minimum of two elevations for additions and remodels. Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full -size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing (prescriptive path) and/or lateral analysis plans. Must indicate details and locations; for non - prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor /roof framing. Provide plans for all floors /roof assemblies, Indicating member sizing, spacing, and'bearing locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered systems, see item 22, "Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists over 10 feet long and/or any beam/joist carrying a non - uniform load. 20 Manufactured floor /roof truss design details. 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas- piping schematic is required for four or more appliances. 22 Engineer's calculations. When required or provided, (i.e., shear wall, roof truss) shall be stamped by an engineer or architect licensed in Oregon and shall be shown to be applicable to the project under review. JURISDICTIONAL SPECIFICS 23 Five (5) site plans are required for Item 11 above. Site plans must be 8 -1/2" x 11" or 11" x 17 ". 24 Two (2) sets each are required for Items 16, 19, 20 & 22 above. 25 Building plans shall not contain red lines or tape -ons. "Mirrored" building plans will be not accepted. 26 "Reversed" building plans must meet criteria outlined in the Permit & System Development Fees document. 27 "Drawn to scale" indicates standard architect or engineer scale. 28 Site plan to include tree size, type & location per approved project street tree plan (if applicable), and COT Street Tree List. Checklist must be completed before plan review start date. Minor changes or notes on submitted plans may be in blue or black ink. Red ink is reserved for department use only. 440-4614 (6100 /COM) CITY OF TIGARD 24 -Hour - BUILDING Inspec 'on e: 639 -4175 INSPECTION DIVISION Busine . (503) 639 -4171 MST c BUP Received Date Requested /.2-4/ AM q ' � `-' PM Cr 3 — oda:3 gS'�a5 ct Location �.P..nT�✓ Suite MEC Contact Person Ph ( ) 6 - 9�g� PLM Contractor • Ph ( ) SWR BUILD Tenant/Owner ELC noting Foundation ELC Access: Ftg Drain ELR Crawl Drain Slab Inspection Notes: � ( v IT Post & Beam Shear Anchors Ext Sheath/Shear Int Sheath/Shear Pa - 'd 0 - `- . Framing - 5 Insulation COMP Drywall Nailing Firewall Fire Sprinkler Fire Alarm Susp'd Ceiling Roof Otp= • er PAS PART FAIL PLUMBING Post & Beam Under Slab R AP ough -In Water Service _ ` AP Sanitary Sewer Rain Drains Catch Basin / Manhole Storm Drain Shower Pan Other: Final PASS PART FAIL MECHANICAL Post & Beam Rough -In Gas Line Smoke Dampers Final PASS • PART _, FAIL - ELECTRICAL Service Rough -In UG/Slab Low Voltage Fire Alarm Final Reinspection fee of $ required before next inspection. Pay at City Hall, 13125 SW Hall Blvd. PASS PART FAIL SITE LI Please call for reinspection RE: U spect= -no-access -- Fire Supply Line ADA / _iry7/ Approach/Sidewalk Dat Inspector Ext Other: Final DO NOT REMOVE this inspection ecord from the Job site. PASS PART.. FAIL