Correspondence et-- a JOHN H. ROMISH ARCHITECT 2216 S.E. 24th Portland, Oregon 97214 503/236 -6306 RECEIVED November 20, 1995 NOV 2 0 1995 COMMUNITY DEVELOPMENT City of Tigard Building Department Plans Examiner James Funk 13125 SW Hall Boulevard Tigard, Oregon 97223 Re: American Show Management Plan Check #10 -57C �1 -69.60-S-W:- Upper- Boones -Fern oad Your letter of 11/16/95 Dear Jim, We have addressed the items in your letter and this is a summary review. Accessi 'Iity . The budget of 106,000.00 dollars for this renovation includes 25% or 26,500.00 dollars for ADA upgrades. We are revamping the toilet rooms, we are changing all door hardware to levers, and we are rebuilding the lunch room counter to meet ADA requirements. These costs are in excess of the 26,500.00 and therefore we did not correct the clearances for door 110. Fire and Life Safety 4 _ 1 7 . All relights shall use tempered glass' per the requirements of 5406 (d) 3. 2. Electrical plans that have been submitted show the require• � / illumination for this space. 6 Fire extinguishers will be provided per the code in locations agreed by the fire inspector prior to occupancy. Mechanical 1. The mechanical contractor has submitted plans for this renovation with the required application. • Fire Sprinklers V1. The fire sprinkler contractor has submitted his plans with the required application. Sincerely, 7 /John H. Romish cc: Richard Krippaehne ProTemp ,a Atik CITY OF TIGARD November 16, 1995 . OREGON John Romish 2216 SE 24th Avenue Portland, OR 97214 Re: AMERICAN SHOW 16160 SW Upper Boones Ferry Road PC10 -57C BUP95 -0450 The plans and specifications have been reviewed for conformity to applicable codes. Please submit three (3) sets of revised plans and specifications incorporating the following requirements: Accessibility Doors accessible for persons with disabilities shall have an 18" w}}de maneuvering space adjacent to the latch side of the pit.., do r./[Section 3109 (1) 3, Table 31E and Figure 25] . Doors is& �ing closer and a latch shall have a latch side approach of lh� 41J 18" on the pull side and 12" on the push side for a front approach [Section 3109(1 -3) and Table 31F]. Provide � accessible egress from Room 110. 0 LEI w ay Fire and Life Safety G(/ Glazing, in fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24" arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60" above the walking surface, shall be tempered [5406(d)3]. Provide specifications for all relites. 2. Provide exit illumination having an intensity of not less than 1 foot candle at floor level, and provide a separate power source, such as an on -site generator or storage batteries to operate the lighting system in the exiting system [Section 3313 (a) (b)] . Provide Type 2 -A fire extinguishers throughout so that the travel distance to a unit does not exceed 75 feet [NFPA 10 3.2.1] . Mechanical il � A permit is required for any modification to the mechanical system. Submit an application and three (3) sets of plans for review. 1- 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 ,. John Romish November 16, 1995 pg. 2 T F Sprinklers 1. A permit is required for any modification to the sprinkler system. Submit an application and three (3) sets of plans and calculations for review. If you wish to discuss any of these items, please give me a call. Sincerely, James Fun Plans Examiner bup95- 0450 \pc10 -57c